METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES
|
|
- Jared Bishop
- 6 years ago
- Views:
Transcription
1 This Document is designed to cover best practice installation methods for the installation of a class 2/3 waterproof membrane system to external concrete balconies in accordance with AS PRELIMINARY WORK Ensure that all surface preparation work, including falls, levels, is complete and properly constructed to enable the membrane system to work as recommended and intended. Ensure that the concrete substrate has been allowed to cure for 28 days and has a moisture content of less than 75% RH before commencing any membrane application. Prepare surfaces, including vacuum cleaning and or diamond grinding as necessary to leave surface smooth, clean, dry and free of all debris. ACCEPTANCE OF SUBSTRATE Confirm and ensure that the substrate complies with relevant substrate standards for Waterproof membrane Systems, including correct falls, drainage points, and window and door set-downs. Ensure that the substrate is structurally sound with no visible ponding water. SURFACE TEMPERATURES Do not install any liquid applied membranes to substrates where the surface temperature is increasing or between 10 c or above 35 c. All Envirotech waterproofing solutions systems installed to hot or cold substrates will obviously present problems due to accelerated and decelerated cure times. When and where possible, all membrane installations should be scheduled when temperatures are decreasing this can be early morning or late afternoons. SURFACE PREPARATIONS Surface preparation is the most critical aspect of installing any waterproofing membranes and coating. Ensure that the substrate is clean from all dirt and other contaminants; floor may have to be washed. Ensure that all water falls to drainage outlets, and all wall rendering has not been completed.
2 When evaluating the substrate for preparation, certain aspects should be considered as follows: Porosity of substrate for primers Surface type and thickness. Condition and stability of the substrate. Moisture Tolerance and density. Degree of contamination. Curing compounds or release agents. When the substrate has been inspected for the above criteria s, it is then possible to prescribe the correct preparation and primers to complete the installation of the membrane system. PREPARATION METHODS Bevel by grinding all concrete edges by mechanical means to eliminate sharp edges Clean and prime High Pressure water-blasting Grinding Vacuuming
3 CONCRETE REPAIRS Repair all areas such as divots, and form work cavity s with suitable concrete repair or similar and smooth off. Repair all concrete structural areas with epoxy gel, smooth off and sprinkle sand to finish. Allow curing for 24 hours. PRIMING APPLICATION Prime substrates thoroughly by brush or roller with the appropriate primer as follows: Two-Part Epoxy primer for all damp surfaces. All Plastic needs to be primed with suitable plastic primers or etched with Acetone. Aluminum needs to be primed with suitable primer or etched with Acetone. All Primers shall be left to cure AS PER RECOMMENDED DATA SHEETS. Where an existing coating is present or the substrate is different, confirm with Enviro-Tech on the appropriate primer to be used.
4 CONCRETE CRACKS/SHRINKAGE CRACKS All cracks over 2mm shall be chased to a depth of 12 mm and filled with epoxy and sand seeded, or an MS flexible sealant. DOOR/WINDOW STEP DOWNS Install MS sealant 15 mm wide to all junctions and tool off smooth. Reinforce with polyester or 225gsm fiberglass mat to all set downs to a DFT of 1.2 mm making sure membrane system has been installed 200 mm onto balcony floor areas. PERIMETER UPTURNS Install MS sealant 15 mm wide to all junctions and tool off smooth. Reinforce with a polyester or fiberglass mat all upturns to a DFT of 1.2 mm 100 mm above finished floor height or 25 mm above water line. Make sure membrane system has been installed 200 mm onto to balcony floor areas.
5 SPITTER DETAIL Make sure spitters have been installed correctly and detailed as below; MEMBRANE SYSTEM SPITTER UPTURN Prime spitters with the appropriate primer and allow primer to cure. Apply waterproof membrane system to spitter as above.
6 FLOOR WASTE DETAIL All floor wastes shall have a recessed leak control flange installed such as Rock Top Flanges. Prime flange with appropriate primer and allow primer to cure. Install membrane system as below and clip Rock-top flange over membrane when cured.
7 MEMBRANE INSTALLATION Apply one coat of waterproof membrane to floor areas, and reinforce with polyester or 225 fiberglass mat rolling sideways to the drainage outlets. Allow a minimum 24 hours drying at a temperature of 25 for first coat to cure correctly. Apply a second coat of waterproof membrane, rolling in a straight line towards drainage outlets. DFT shall be 1.5 mm, or a third coat shall be applied after a minimum of 24 hours curing at a temperature of 25 COMMENTS; MS SEALANTS CAN ONLY BE USED WITH WATER-BASED MEMBRANE SYSTEMS. TILE FIXING Tile adhesives should be compatible with the membrane system installed. TILE CONTROL JOINTS Shall be to AS
8 COMPLETION METHOD STATEMENT Take a dated picture by camera, and store in folder. Clean up all empty buckets and materials and remove. Leave all work in a sound a condition and defect free. COMMENTS; Over the years I have seen many concrete balcony s leak due to concrete cracking which in turn ruptures the membrane causing the balcony to leak. Completely reinforcing the membrane system will give the membrane greater strength and allow the membrane system to function better when the concrete cracks. When you look at any old roofs or balcony s that were fully reinforced with fiberglass, they still looked sound, with no membrane cracking even after the concrete had cracked under the membrane. When a flexible membrane system is installed directly onto concrete without being fully reinforced, nine times out of ten, the membrane system will fail when the concrete cracks.
9 Reference Contacts and Data: Technical data, advise or technical assistance may be obtained by contacting Enviro-Tech Waterproofing Solutions at:- Web Page Office Telephone: (07) Office Fax: (07) John Blasé Mobile: Postal address: Unit 254Robinson Road East Geebung Qld 4034 Australia Do it Once-Do it Right-Fixed for Good
10
METHOD STATEMENT 003 SCYRON-CEMENT SHEETING BALCONY WATERPROOFING FOR DIRECT FIXED TILES
This Document is designed to cover best practice installation methods for the installation of a class 2/3 waterproof membrane system to external Scyron-cement sheet balconies to AS 4654.2 PRELIMINARY WORK
More informationMETHOD STATEMENT 007 CEMENTITIOUS APPLIED MEMBRANE TO CONCRETE WALLS
This Document is designed to cover best practice installation procedures for a cementitious liquid applied membrane system to concrete basement walls. PRELIMINARY WORK Ensure that all surface preparation
More informationWPM WATERPROOFING MEMBRANE
WPM 300 - WATERPROOFING MEMBRANE Description WPM 300 Waterproofing Membrane is a single-pack, water based polyurethane modified synthetic rubber polymer, liquid membrane developed specifically as a tough,
More informationERSYSTEMS OneStep Plus
1 DG0045-C 052017 CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline ERSYSTEMS OneStep Plus ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:
More informationURETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline
1 DG0049-A 052017 CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939
More informationSIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017
SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746
More informationMETHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM)
METHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM) 1 SCOPE This method statement describes the step by step application of 1-component component, liquid applied, highly elastic polyurethane waterproofing
More informationKOSTER AMERICAN CORPORATION
Section 09699 PART 1 GENERAL Water Vapor Emission Control Systems 1.1 RELATED DOCUMENTS A. Drawings, documents, and general provisions of the Contract, including, but not necessarily limited to, General
More informationCARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS
CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS 1. GENERAL A. When coating over existing coatings, Carlisle can not assume responsibility for the adhesion of the existing coating,
More informationDESCRIPTION FEATURES AND BENEFITS AREAS OF USE. Showers & Bathrooms. Balconies & Patios SUITABLE SUBSTRATES. for application on: Concrete & Masonry
Product Information Technical Data Sheet - August 2017 High Performance DESCRIPTION Crommelin High Performance Under-tile Waterproof Membrane is an exceptionally flexible, 2 part cementitious, positive
More informationAS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings
AS4654.2 Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings Climate Zone: 6 Wind Class: N1 Membrane Types: Liquid Applied Class II and Class III as defined and tested
More informationAQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters
AQUATITE Revision Date: september 2007 Description Bondall AquaTite is a grey, brushable, waterproofing coating that forms a flexible yet tough, seamless membrane. This single pack product exceeds the
More informationDS411 Exterior. Product. BRANZ APPRAISAL No. 788 (2012) Scope. Wet-seal New Zealand Ltd P O Box Takapuna Auckland Tel:
Product 1.1 Wet-seal DS411 Exterior Waterproofing Membrane is a single part waterproofing membrane for use under ceramic or stone tile finishes on external decks and balconies. Appraisal No.788 [2012]
More informationNational Construction Code Series (NCC 2016) Building Code Of Australia (BCA)
Appraisal No. 958 [2017] HYDRATHANE EXTERIOR WATERPROOFING MEMBRANE BRANZ Appraisals Technical Assessments of products for building and construction. Construction Chemicals Pty Ltd 49-57 Davis Street Wingfield
More informationINSTALLATION METHOD STATEMENT
INSTALLATION METHOD STATEMENT 1.0 Introduction - Liquid screed is a flowing screed flooring system comprising a calcium sulphate binder, fine aggregate and water. - It is for internal use only, in general
More informationURETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline
1 DG0001-J 05/2017 Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:
More informationBRANZ Appraisal Certificate # 461 (2010) Internal wet areas.
SPECIFICATION FOR PROTECTO WRAP AFM-WM FOR INTERNAL WET AREAS BRANZ Appraisal Certificate # 461 (2010) Internal wet areas AFM/WM INTERNAL 0104 Page 1 AFM-WM INTERNAL SPECIFICATION PRODUCT DESCRIPTION Anti
More informationOutline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)
Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is
More information1/16 Single Broadcast Polymer Flooring System
specification 1/16 Single Broadcast Polymer Flooring System Part 1 - GENERAL General Provisions A. Work to be covered by this section, under written specification or by drawing, shall comply with all provisions
More informationTECHNICAL BULLETIN TB006
TECHNICAL BULLETIN TB006 TB006.014 ARDEX Australia 2003-2017 Date, Monday, 8 May 2017 THE ARDEX MOISTURE BARRIER SYSTEMS INTRODUCTION & SCOPE Internal concrete substrates come in many different forms new
More informationHYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals
HYDRATHANE INTERIOR WATERPROOFING MEMBRANE BRANZ Appraisals Technical Assessments of products for building and construction. Construction Chemicals NZ Ltd 16 Carpenter Road East Tamaki Auckland Phone (09)
More informationHYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals
Appraisal No. 959 [2017] HYDRATHANE INTERIOR WATERPROOFING MEMBRANE BRANZ Appraisals Technical Assessments of products for building and construction. Construction Chemicals Pty Ltd 49-57 Davis Street Wingfield
More informationSURFACE PREPARATION INSTRUCTIONS: CONCRETE
SURFACE PREPARATION INSTRUCTIONS: CONCRETE DEFINITION OF TERMS The terms listed will be used frequently throughout this article and listed in boldface for ease of reference. They describe, in detail, the
More informationACRYLIC. AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline
1 DG0013-J 04/2017 AGED (PVC, CPE, CPA) SINGLE-PLY (Thermoplastic) Membrane Restoration Sample Design Guideline ACRYLIC ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel:
More informationSPECIFICATION JAYDEX SHEET MEMBRANE SYSTEM WITH AN ASPHALTIC OVERLAY ON A CONCRETE VEHICLE DECK
NOVA270C APRIL 2014 SPECIFICATION JAYDEX SHEET MEMBRANE WITH AN IC OVERLAY ON A CONCRETE VEHICLE DECK INTRODUCTION This specification includes the preparation for and installation of the Jaydex Novabond
More informationProduct Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification
Product Data Sheet Pondseal Waterproofing Membrane for Ponds and Water Features Description Pondseal is a polyurethane / acrylic co-polymer, water based coating which when fully cured, forms an impervious,
More informationDRYPROOF UNDER TILE EXTERNAL WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 887 [2015] Appraisal No. 887 (2015) Amended 17 September 2015
DRYPROOF UNDER TILE EXTERNAL WATERPROOFING Amended 17 September 2015 BRANZ Appraisals Technical Assessments of products for building and construction. Drymix NZ Ltd PO Box 109 Greenhithe Auckland 0756
More informationRUBBERGUARD LIQUID APPLIED WATERPROOFING
RUBBERGUARD LIQUID APPLIED WATERPROOFING 1. GENERAL This specification relates to the supply and installation of the RUBBERGUARD Liquid applied reinforced waterproofing membrane for use under tiles, external
More informationTechnical Data Sheet
7 February 2018 ACRYLIC EMULSION MEMBRANE GREY OR WHITE WATERPROOFING MEMBRANE ROLLER GRADE DESCRIPTION Actech AT-102 UV Technical Data Sheet ACTECH AT-102 UV is a Class 111 Pure Acrylic Emulsion Flexible
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationOutline NBS Specification. Protec System to Felt (Waterproofing Only)
Outline NBS Specification Protec System to Felt (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is always recommended.
More information3-component epoxy self-smoothing screed
Construction Product Data Sheet Edition 26/07/2016 Identification no: 01 08 01 02 050 0 000017 3-component epoxy self-smoothing screed Product Description Uses Characteristics / Advantages Product Data
More informationLIQUID APPLIED WATERPROOF ROOF COATINGS
J31 LIQUID APPLIED WATERPROOF ROOF COATINGS To be read with Preliminaries/General conditions. TYPE(S) OF COATING 110 COLD DECK ROOF COATING Substrate: New / existing concrete deck / screed. o Preparation:
More informationAS The External Waterproofing Membranes Standard
AS 4654-2 The External Waterproofing Membranes Standard NOTE This external waterproofing standard contains solutions for problems which have not been addressed in other countries. CONFORMANCE CONDITIONS
More informationRESIN FLOORING. To be read with Preliminaries/ General Conditions TYPE(S) OF FLOORING
M12 To be read with Preliminaries/ General Conditions TYPE(S) OF FLOORING 110A - Primer reference: None or Altro Prime standard dependant on substrate - Resin flooring reference: Altro Grip 1mm slip-resistant
More informationColphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate
Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More information2. Subfloor Preparation - Removal of Existing Floor Coverings
Generic Scope of Works - Forbo Sure Step and Safe Step Sheet Vinyls 1) Subfloor Preparation - New Concrete Floors 2) Subfloor Preparation Preparing Existing Concrete / Removal of Existing Floorcoverings
More informationFLUID APPLIED WATERPROOFING
SECTION 07120 FLUID APPLIED WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09200 - Metal Studs, Metal Lath, Suspension Ceilings, Plaster, and Stucco.
More informationEngine Bay Floors Floor Resurfacing 4000
Engine Bay Floors Floor Resurfacing 4000 P.O. Box 341 Macungie, PA 18062 610.530.7710 800.573.9198 www.enginebayfloors.com 1.1 SUBMITTALS Flooring Specification SECTION 1 GENERAL A. Product Data: Submit
More informationWATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING
WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING 4 5 6 7 3 2 1 1. CONCRETE
More informationA. Submit product data sheets and literature verifying physical properties of materials.
I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving EPDM Roofs 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor,
More informationTechnical Data Sheet
Updated 19 Dec 2017 Actech AT-906 WPU Technical Data Sheet WATER BASED POLYURETHANE GREY WATERPROOFING MEMBRANE ROLLER GRADE DESCRIPTION * ACTECH AT-906-WPU is a Class 111 water based modified polyurethane
More informationPRIMERS & MOISTURE CONTROL SYSTEMS
PRIMERS & MOISTURE CONTROL SYSTEMS SYSTEMS FOR INDUSTRIAL, RETAIL, RESIDENTIAL & PUBLIC BUILDINGS UZIN. THE FLOOR BELONGS TO YOU. Why UZIN Primers & Moisture Control Systems? Unique Systems UZIN has long
More informationMaster-Seal Surface-Applied Waterproofing System
P 1/7 INDUSTRIAL ROOFING, INC. Master-Seal Surface-Applied Waterproofing System Master-Seal is a highly effective waterproofing system designed to seal surfaces from water seepage in roofs with minimum
More informationDECOCOLOR FLOORING SYSTEM
AIA Specification DECOCOLOR FLOORING SYSTEM Part 1 - GENERAL General Provisions A. Work to be covered by this section, under written specification or by drawing, shall comply with all provisions of the
More informationSECTION mil thickness COLD FLUID-APPLIED WATERPROOFING
SECTION 07 14 16 CCW-MIRASEAL @ 120 mil thickness COLD FLUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationFlorock Seamless Flooring Systems
Architectural Specification -- FloroCryl Deck- 1/8 (125 mil) MMA (Methyl Methacrylate) Waterproofing 1/8 Flooring System Part 1: General 1.01 System Description A. Roller-applied penetrating MMA primer
More informationTECHNICAL BULLETIN TB147 THE INSTALLATION OF ARDEX DS40 SOUND REDUCTION MATTING IN INTERNAL INSTALLATIONS
TECHNICAL BULLETIN TB147 THE INSTALLATION OF ARDEX DS40 SOUND REDUCTION MATTING IN INTERNAL INSTALLATIONS TB147.004 Ardex Australia 2008-2014 Date, Wednesday, 12 March 2014 INTRODUCTION & SCOPE There is
More informationDATA SHEET DEKSTER 131 SELFLEVELLING FLOOR COAT / UNDERLAY
(Page 1 of 8 ) GENERAL DESCRIPTION - Dekster 131 self levelling is a contemporary coating that achieves hard wearing, utilitarian floor surfaces in a range of natural tones to offset any style of interior.
More informationACRYLIC Elastek #127 Solar One Plus
1 EL0003-N 01/2018 Asphalt Restoration New or Aged BUR and Modified Bitumen Sample Design Guideline ACRYLIC Elastek #127 Solar One Plus ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving,
More informationINFORMATION. Product Information Sheet Regupol Resilient One Part Adhesive
Page 1 Product Information Sheet Regupol Resilient One Part Adhesive DESCRIPTION The Regupol Resilient One Part Adhesive is a water based synthetic polymer, VOC compliant resilient flooring adhesive. This
More informationPOLYURETHANE FOAM SAMPLE DESIGN GUIDELINES URETHANE
1 DG0034-H 05/2017 POLYURETHANE FOAM SAMPLE DESIGN GUIDELINES URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939 www.itwsealants.com
More informationLUXAPOOL CHLORINATED RUBBER POOL COATING
Page 1 LUXAPOOL CHLORINATED RUBBER POOL COATING POOLS PREVIOUSLY PAINTED WITH CHLORINATED RUBBER SURFACE PREPARATION 1. Using a stiff brush or broom, scrub the entire surface with diluted LUXAPOOL Concentrated
More informationBEAL Appraisal Certificate Easygum Liquid Applied Waterproofing Membrane System
BEAL Appraisal Certificate No. M1024 [2017] Easygum Liquid Applied Waterproofing Membrane System EXPIRES August 2018 Product 1.1 This Appraisal Certificate covers the EASYGUM Waterproofing Membrane System
More informationSIKA CAR PARK DECK SYSTEM. Product. Scope. Appraisal No. 781 [2019] Appraisal No. 781 (2019) This Appraisal replaces BRANZ Appraisal No.
Appraisal No. 781 [2019] SIKA CAR PARK DECK SYSTEM This Appraisal replaces BRANZ Appraisal No. 781 (2012) s Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192
More informationERSYSTEM ONESTEP PLUS
1 DG0047-A 05/2017 AGED (EPDM, TPO, CSPE-HYPALON, PIB) SINGLE-PLY (THERMOSET) MEMBRANE RESTORATION SYSTEM APPLICATION SAMPLE DESIGN GUIDELINE ERSYSTEM ONESTEP PLUS ITW POLYMERS SEALANTS NORTH AMERICA,
More informationInstallation Guide. Preparation of a Polished Concrete Subfloor up to 98% RH
Installation Guide The following is a guide of how to install IOBAC paramagnetic resin over the following substrate. This is a guide listed out in bullet points for you to follow as a continuation to your
More information(Superflex Bathroom and Balcony Two Part) Two Component Undertile Waterproofing Membrane
Two Component Undertile Waterproofing Features Rapid drying time Two component undertile waterproofing membrane Advanced acrylic will not re-emulsify Liquid reinforced eliminates the need for reinforcing
More informationSECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 05 16 SUBSURFACE PREPARATION FOR FLOOR FINISHES SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph
More informationSILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION
SILASEC WP0001 REVISED: JANUARY 2002 DESCRIPTION Bondall Silasec is a concentrated liquid waterproofing compound designed to be used with Portland type A or type GP cements to form a permanent waterproof
More informationBENEFITS & ADVANTAGES:
APPLICATION GUIDELINES The following KARNAK Roof Restoration System is intended to be applied over sound metal roofing systems with a weathered Kynar coated metal finish. BENEFITS & ADVANTAGES: Elastomeric
More informationARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment
ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment SECTION 03 01 30 Maintenance of Cast-In-Place Concrete PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings, general
More informationARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors
ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors SECTION 03 54 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings, general provisions of
More informationRedLINE MOPPING INSTALLATION
INTRODUCTION RedLINE MOPPING INSTALLATION FOR USE WITH: HOT RUBBERIZED ASPHALT This installation technique is used predominantly in waterproofing systems that are on green roofs, below grade or on plaza
More informationULTRATUFF Waterproofing membrane 001 FC LIQUID LATEX DECKING MEMBRANE
Technical Data Sheet Date NOV 2015 Replaces July 2012 ULTRATUFF Waterproofing membrane 001 FC LIQUID LATEX DECKING MEMBRANE DESCRIPTION: Ultratuff 001 FC is a reinforced waterproofing deck membrane. It
More informationSpecifications. Specifications (Architectual) Metallic System. Metallic System
(Architectual) Metallic System Architectual NeverStrip Floor Coatings, 6-15 Mils Master Format Section 096700 Fluid Applied Flooring 1 of 6 NeverStrip Metallic High-Build Decorative Epoxy/Urethane Coating
More informationMaintaining Building Envelope Integrity. Is Your Leak REALLY a Roof Leak?
Maintaining Building Envelope Integrity Is Your Leak REALLY a Roof Leak? Learning Objectives: At the end of the program, participants will be able to: Recognize what is, and what is not, a roof leak. Identify
More informationProduct Size Thickness Installation direction Seams treatment
INSTALLATION INSTRUCTIONS FOR GERFLOR SAGA 2, CREATION TILES AND PLANKS This document refers to the following products: Product Size Thickness Installation direction Seams treatment Creation Tiles See
More informationARDEX WPM 001. One-Part Undertile Waterproofing Membrane. Fast-drying acrylic undertile liquid waterproofing membrane
Fast-drying acrylic undertile liquid waterproofing membrane Class III Membrane - Conforms to AS4858:2004 BRANZ Appraised (No. 472 and No. 473) Suitable for internal use Low VOC content meets Green Building
More informationFlorock Seamless Flooring Systems
Architectural Specification Florotallic Epoxy and Urethane Flooring System Part 1: General 1.01 System Description A. Roller-applied 100% solids, penetrating pigmented epoxy primer, decorative pigmented
More informationWATERPROOFING OF BALCONIES. COLD-LIQUID APPLIED.
WATERPROOFING OF BALCONIES. COLD-LIQUID APPLIED. 0) Introduction & summary of systems This document explains the different systems that Krypton Chemical, SL. proposes for the liquid cold applied waterproofing
More informationASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS
ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS Re-Ply Roofing Systems Application Specification # AC - 2010-A & MB PART I GENERAL 1.01 DESCRIPTION A. This guideline specification includes
More informationFosroc Nitoproof 800 Method Statement
Fosroc Nitoproof 800 Method Statement constructive solutions Section A : Health, Safety and Environment A1. Personal safety requirements: 1.1 Application should be in accordance with local / site regulations.
More informationSECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof
SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812
More informationGUIDE TO DUKKABOARD AQUA 77
GUIDE TO DUKKABOARD AQUA 77 Dukkaboard Telephone 08701 271300 support@dukkaboard.com www.dukkaboard.com Dukkaboard 2013 Issue DK1 11.13 E & OE For a totally waterproof solution, choose Dukkaboard tile
More informationSECONDARY CONTAINMENT COATING SPECIFICATION
SECONDARY CONTAINMENT COATING SPECIFICATION 1.0 GENERAL PROVISIONS Applicable to the following areas: Typical concrete secondary containment structure with occasional exposure acidic and alkaline compounds
More informationProtective Industrial Polymers - USA Manufacturer s Specification February 11, 2015
This specification covers InhibiChem SR-GF-L Enhanced Chemical and Solvent-Resistant Glass-Flake Reinforced Steel Tank Lining System. This system consists of a vinyl ester primer, and two troweled coats
More informationFlorock Seamless Flooring Systems
Architectural Specification Floropoxy/Florospartic 5 Self-Leveling Epoxy/Polyaspartic Flooring System Part 1: General 1.01 System Description A. Roller applied 100% solids, penetrating pigmented epoxy
More informationSECTION A. Schönox AP- Synthetic Gypsum Self Leveling Underlayment. B. Schönox VD-Primer for porous substrates
SECTION 03540 RECOMMENDED SPECIFICATION FOR SYNTHETIC GYPSUM SELF LEVELING UNDERLAYMENT COMPOUND FOR CRITICAL SUBSTRATES SUCH AS: GYPSUM, WOOD, CERAMIC, TERRAZZO, SHEET VINYL, OSB BOARD AND PLYWOOD PART
More informationPERMAPHALT MASTIC ASPHALT ROOF WATERPROOFING SYSTEM. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals
PERMAPHALT MASTIC ASPHALT ROOF WATERPROOFING SYSTEM s Technical Assessments of products for building and construction. Neuchatel Limited 5a Miro Place Albany Auckland Tel: 09 441 4595 Email: info@neuchatel.co.nz
More informationFor RSA Coating Systems over For RSA Coating Systems over Austech Foamula Extruded Polystyrene (XPS) (Skin Off)
Austech Foamula Extruded Polystyrene (XPS) (Skin Off) RSA strongly recommend the use of our full render and texture systems with the appropriate water tight membrane over polystyrene products. SEVEN STEPS
More informationFlorock Seamless Flooring Systems
Architectural Specification Florotallic Epoxy and Urethane Flooring System Part 1: General 1.01 System Description A. Roller-applied 100% solids, penetrating epoxy primer, decorative pigmented epoxy coatings
More informationSystem Recommendation SR0618
Ardex Australia Pty Ltd ABN 82 000 550 005 Unit 7, 20 Powers Road, Seven Hills NSW 2147 Australia Telephone + 61 2 9851 9100 Facsimile +61 2 9838 7970 www.ardexaustralia.com System Recommendation SR0618
More informationPacific Polymers Elasto-Deck 5000MR Guide Specification
1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000MR OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More informationPacific Polymers Elasto-Mat D&G Guide Specification
1 07141-1 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141
More informationACRYLIC Elastek #127 Solar One Plus
1 EL0017-L 01/2018 AGED (EPDM, TPO, CSPE-HYPALON, PIB) SINGLE-PLY (THERMOSET) MEMBRANE RESTORATION SYSTEM APPLICATION SAMPLE DESIGN GUIDELINE ACRYLIC Elastek #127 Solar One Plus ITW POLYMERS SEALANTS NORTH
More informationBENEFITS & ADVANTAGES:
APPLICATION GUIDELINES WHITE REFLECTIVE The following KARNAK Roof Restoration System is intended to be applied over sound, dry, existing smooth built-up asphalt and smooth or granular modified bitumen
More informationManufacturers and suppliers of quality coating systems and associated materials to the Floor Covering and Building Industries
to the Floor Covering and Building Industries FACT SHEET no.1 SUBSTRATE INSPECTION: Inspect the substrate thoroughly for any evidence of contamination that could jeopardise the integrity of the new DURON
More informationPOLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC
1 DG0030-J 04/2017 POLYURETHANE FOAM SAMPLE DESIGN GUIDELINE ACRYLIC ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939 www.itwsealants.com
More information1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets
This specification covers InhibiChem CR-GF-L Chemical-Resistant Glass Flake-Reinforced Steel Tank Lining System. This system consists of a vinyl ester primer, and two troweled coats of glass flake filled
More informationTILE TILE
09300 - TILE 09300-1 PART ONE: GENERAL 1.1 Description TILE 1.1.1 Work of this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance with the requirements
More informationFlorock Seamless Flooring Systems
Architectural Specification -- FloroCryl Shop MMA (Methyl Methacrylate) - Silica Sand Single Broadcast 1/16 (1.59 mm) Flooring System Part 1: General 1.01 System Description A. Roller-applied penetrating
More informationA-9,250 Parking Structure Resurfacing Cement Look
A-9,250 Page 1 A-9,250 Parking Structure Resurfacing Cement Look Description This specification includes the repair and resurfacing methods used when applying Americrete products over cracked, spalled,
More informationDAVCO K10 PLUS AND K10 RAPID EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 608 [2017]
WATERPROOFING MEMBRANES This Appraisal replaces BRANZ Appraisal No. 608 (2008) Amended 24 May 2018. BRANZ Appraisals Technical Assessments of products for building and construction. ParexGroup Pty Limited
More informationMethod Statement. For RSA Coating Systems Over M Grade Expanded Polystyrene (EPS)
Method Statement For RSA Coating Systems Over M Grade Expanded Polystyrene RSA strongly recommend the use of our full render, texture paint systems over polystyrene substrates. We DO NOT recommend mixing
More informationTERRADECRA DECORATIVE STONE CARPET
TECHNICAL DATA Technical data may be updated at any time. It is the users responsibility to check data validity by reference to the website or Nuplex Construction Products MANUAL SECTION ISSUE DATE AUTHORISED
More informationMEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils
GREEN BUILDING FEATURES Contributes towards satisfying Credit 4.2 under LEED Contains recycled post industrial crushed glass Contains rapidly renewable materials Meets California South Coast Air Quality
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1007 REVISION 13 DECEMBER 2013 EFFECTIVE DATE DECEMBER 16,
More information