OPDISYS Fiber to the Home - Solution

Size: px
Start display at page:

Download "OPDISYS Fiber to the Home - Solution"

Transcription

1 OPDISYS Fiber to the Home - Solution

2 Optical distribution system OPDISYS -rack The OPDISYS -rack was specially designed for Fiber-To-The-Home (FTTH) applications. It is a modular system consisting of a basic rack, cable management, mandrel extension racks and gasblocker extension racks and fiber modules. Thanks to its design this system is very flexible. The extension racks can be ordered and combined individually according to the customer s needs. Each fiber module has a front plate with two types of uniform cut-out patterns into which snap-in angled holders fitting into the required adapter type can be inserted. This snap-in angled holder also ensures a 45 degree angle of the adapter is maintained. Each fiber module can be used as a left-side as well as a right-side fiber module. By default, there are protection tubes from the cable clamp to each individual module is installed by kink-resistant PBT-tubes. They ensure that the minimum curve radius of the cable loose tubes from the cable entry to the fiber modules will not be exceeded. The cable clamps are pre-installed either on the top or on the bottom of the rack and are used to secure the strain relief of the incoming cables. They serve further as a fixing point for the cable tubes. Optionally, the strain relief element of the incoming cable to be attached. Technical data: maximum fiber density: 960 fibers at SC, 1920 fibers at LC and E2000 comfortable patching with two-sided overlength patchcord storage optional extensions (for cable guidance and gasblocker integration) available as open and closed rack version removable and rotatable splice/patch fiber module fiber module frontplate with different cutouts and adapter mounting through snap-in angled holder available: SC, LC, E2000 (others on request) optional integration of gas-blockers on incoming tubes possible (on request) colour: RAL 7035, light grey material: Powder coated steel flammability: UL 94V-0 The OPDISYS -rack is the core component of every OPDISYS -system. Both, an open version as well as a closed version, are available. An open version rack is turned into a closed version rack by installing side panels and doors. The rack accommodates the fiber module carrier, the cable entry plates, all types of extension modules and, if a closed version is required, the side panels as well as the front doors. Various fixing sets (see information in the accessories section of this document) are available which allow you to mount the rack to either wall or ceiling or floor. It is possible to mount several racks next to each other back-to-back (requires only floor mounting) or next to each other (requires mounting both to floor and ceiling or wall for stability reasons). A stand-alone Single Row Rack should always be fixed to both floor and ceiling or wall.

3 Rack features: top or bottom cable entry possible top cover provides openings for cables (optionally with brushes) easy expansion with side-by-side or back-to-back mounting of racks solutions for cross-connect and interconnect configurations backside vertical cable guidance for incoming cables bending radius protection of 30mm for fibers and patchcords intelligent patchcord management vertical patchcord cable guidance on left and right side mandrels on left and right side of the rack provide sufficient space for patchcord overlength storage integrated patchcord management to adjacent racks avoids the usage of external ducts Dimensions & capacity - standard version (incl. mandrels) Rack height Rack width Rack weight (open / closed) Max. amount of modules Max. amount of terminations OPDISYS -rack 1000/40HU incl. mandrels, protective tubes OPDISYS -rack 1000/40HU 2200 mm 1000 mm 118 kg / 170 kg 80 Full-Size or 160 Half-Size 960 SC 1920 LC / E2000 Art. No OPDISYS -rack - possible extensions (on request) Gasblocker - extension rack When using blow-in systems, gasblockers are essential in order to protect the installation against gas and/or water entry. The gasblocker extension rack can accommodate the gasblockers. It has a built-in back panel, so no extra back panel is needed in order to turn it into a closed version. Rack doors, side and back panels If a closed rack version is required, doors and panels can be attached to rack. Each door has an opening angle of 180. The doors are equipped with an integrated lever and lock and have an A4 document holder on their inner side. Each side panel is useable for right as well as for left side mounting. Gasblocker - extension rack on request Panels / door set Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 3

4 OPDISYS -rack - accessories Fixing sets Several fixing sets are available to mount the rack to the wall, on the floor or to mount multiple racks side by side or back to back to each other. Each individual fixing set contains all necessary screws, mounting brackets, washers and anchor pins. Tool kit adapter holder pincer The adapter holder pincer is designed to easily remove the snap-in angled holder from the frontplate cutout of the OPDISYS fiber module. Thanks to its small and compact design it ensures the smooth removal of a snap-in angled holder without interfering with other connections. torx socket wrench draw wire or element The draw wire or element tool is necessary to insert the incoming fiber cable into the fiber protection tube which is fed up to the fiber optic module. This tool is required to install a OPDISYS -System. Fixing set, back-to-back or side-to-side Art. No Fixing set for double bottoms Art. No Fixing set base with leveling feet Art. No Tool kit Art. No OPDISYS -fiber modules The multi-circuit management fiber modules are used as combined splice & patch modules. They offer highest fiber density along with best maintainability. Maximum flexibility is guaranteed by metal frontplates and 45 angled adapter holders for all conventional adapter types. The fiber modules are available as full-size fiber modules with a height of 1HU. Fiber modules can be equipped with different adapter types or with a closed frontplate without adapters for a splice-through version (in this case, a loop- back connection of fibers can be done via splices). The material of the LSZH fiber modules is a Polycarbonate / ABS blend. The symmetrical design of the multi-circuit management fiber modules allows you to use the same module for left- and right-side mounting. A uniform module colour optimizes stock keeping, while individual threefold colour code labelling (on front, side and cover) provides fast and clear module and fiber identification. On request we can deliver each fiber module with a customized labelling of the top cover (index of all ports with description) as well as a labelling of the side of each Fiber Module (indication of the street and the building this module is assigned to) according to the customer s request. Also the labelling of the fiber module numbering can be done by us. fiber modules can be rotated by 90 and are removable from the rack incoming fibers and pigtails are stored in separate areas easy to snap in adapter holders allow comfortable cleaning of pigtail-connector ferrules by taking off the adapter holders. identical splice protection holder for both shrink and crimp splice protection two-sided, easy to remove transparent covers per fiber module bending radius protection for all fibers and pigtails overlength storage of incoming cable subtube is possible on the bottom side of the module Technical Data: Colour RAL 7035, light grey Material Powder coated steel Flammability UL 94V-0 Weight (full size module) 145 grams (without adapters and pigtails) Each Fiber Module is equipped with a frontplate, snap-in angled holders, rubber shrink/crimp splice protection holder, fiber protection pipe holder, two transparent covers, designation label, door latch and inserted adapters and pigtails.

5 Plug-in configuration - fully equipped SC LC E2000 Amount of adapters Amount of pigtails Max. amount of spices Heat shrink splice protection* Crimp splice protection* Max. amount of spices * Heat shrink splice protection or crimp splice protection are not included and must be ordered separately. Fiber module 24 LC/APC, 1HU Art. No Fiber module 24 E2000/APC, 1HU Art. No Fiber module 12 SC/APC, 1HU Art. No Fiber module for up to 48 splices, 1HU Art. No Cable clamp set Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 5

6 Patch cable PC LC/APC simplex, 2 mm Characteristics of LC/APC simplex: user-friendly audible latch to indicate proper mating push-pull locking plastic housing with zirconia ferrule standard IEC insertion loss (IL) for SM (typical) average value <0.15 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) strain relief 100 N PC LC/APC simplex 3 m Art. No PC LC/APC simplex 5 m Art. No PC LC/APC simplex 10 m Art. No PC E2000/APC simplex, 2 mm Characteristics of E2000/APC simplex: locks with locking lever automatic dust protection flap plastic housing with zirconia ferrule standard IEC insertion loss (IL) average value <0.10 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) PC E2000/APC simplex 3 m Art. No PC E2000/APC simplex 5 m Art. No PC E2000/APC simplex 10 m Art. No PC SC/APC simplex, 2 mm The patch cables consist of an inhouse cable with 2 mm outer diameter and is pre-assembled with two connectors. They are used to establish a connection between patch panels / cabinets or terminals. Because of their mechanical stability, patch cables can be used in cabinets, enclosures and with some restrictions in cable ducts. However, they may not be drawn in or injected. Characteristics of SC/APC simplex: automatic lock in adapter unlocks by pulling on housing ( push-pull ) plastic housing with zirconia ferrule standard IEC insertion loss (IL) (typical) average value <0.20 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) PC SC/APC simplex 3 m Art. No PC SC/APC simplex 5 m Art. No PC SC/APC simplex 10 m Art. No

7 Fiber optic cable A-DQ(BN)2Y CT - Outdoor cable, center unitube, D35-S15 outdoor cable rodent protection metal-free longitudinally water-tight A-DQ(BN)2Y CT 12E9/125 Art. No A-DQ(BN)2Y CT 24E9/125 Art. No Type number of numbers of tube-ø tenisle strength outer-ø weight fibers / tube fibers approx. mm max. N approx. mm approx. kg/km A-DQ(BN)2Y CT 12E9/ , ,5 72,8 A-DQ(BN)2Y CT 24E9/ , ,5 73,7 Central loose tube cable for outdoor applications. Rodent protected by glass rovings. This cable is used as low fiber count data cable in distribution networks and meets the demands of outdoor environments. Fibers according ITU-T G.652.D Construction center unitube strength members (aramide yarns) PE-sheath, UV-resistant, black with two orange longitudinal stripes Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colour red Laying usable for fixed laying in ducts or conduits and outdoors Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: torsion: kink, cable: kink, tube: min. bending radius: temperature range: water penetration: according to IEC E1 according to IEC E3 value: 3000 N/10 cm according to IEC E4 value: 5 Nm according to IEC E7 value: 5 cycles ±1 turn according to IEC E10 value: The cables do not form a kink when a loop is drawn together to a diameter of 100 mm. according to IEC E16 value: The loose tubes do not kink. according to IEC E11 value: R = 20 x D (cable outer diameter) according to IEC F1 storage and transport: -40 C up to +70 C laying: -5 C up to +60 C operation: -25 C up to +70 C according to IEC F5 value: No water on free end. OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 7

8 A-DQ(BN)2Y GGT - Outdoor cable, loose tube construction, D23-S20 outdoor cable rodent protection metal-free longitudinally water-tight A-DQ(BN)2Y GGT 2x12E9/125 Art. No A-DQ(BN)2Y GGT 4x12E9/125 Art. No A-DQ(BN)2Y GGT 6x12E9/125 Art. No A-DQ(BN)2Y GGT 8x12E9/125 Art. No A-DQ(BN)2Y GGT 10x12E9/125 Art. No A-DQ(BN)2Y GGT 12x12E9/125 Art. No A-DQ(BN)2Y GGT 8x24 E9/125 Art. No A-DQ(BN)2Y GGT 18x24E9/125 Art. No Type number of number of tubes number of tube-ø tensile strength outer-ø weight fibers/tube + fillers fibers approx. mm max. N approx. mm approx. kg/km A-DQ(BN)2Y GGT 2x12E9/ , ,2 141,7 A-DQ(BN)2Y GGT 4x12E9/ , ,2 145,3 A-DQ(BN)2Y GGT 6x12E9/ , ,5 160,0 A-DQ(BN)2Y GGT 8x12E9/ , ,8 182,5 A-DQ(BN)2Y GGT 10x12E9/ , ,3 214,0 A-DQ(BN)2Y GGT 12x12E9/ , ,0 251,0 A-DQ(BN)2Y GGT 8x24E9/ , ,5 221,8 A-DQ(BN)2Y GGT 18x24E9/ , ,5 335,4 Stranded loose tube cable for outdoor applications. Highly rodent protected by 2 layers of glass rovings. This cable is used as higher fiber count data cable in distribution networks and withstands environments with high mechanical demands. Fibers according ITU-T G.652.D Construction FRP-central element loose tubes, SZ-cabling (if necessary with fillers) dry filled cable core strength members (glass-rovings) ripcord PE-sheath, UV-resistant, black with two orange longitudinal stripes Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colours 1: red 2: green others: nature or white Filler colours black Laying usable for fixed laying in ducts or conduits and outdoors Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: torsion: kink, cable: kink, loose tube: min. bending radius: temperature range: water penetration: according to IEC E1 according to IEC E3 value: 3000 N/10 cm according to IEC E4 value: 10 Nm according to IEC E7 value: 5 cycles ±1 turn according to IEC E10 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. according to IEC E16 value: The loose tubes do not kink. according to IEC E11 value: R = 20 x D (cable outer diameter) according to IEC F1 storage and transport: -40 C up to +70 C laying: -5 C up to +60 C operation: -30 C up to +70 C according to IEC F5 value: No water on free end.

9 A-DQ(ZN)2Y Mini T - Mini cable, loose tube construction, D15-S05 outdoor cable metal-free longitudinally water-tight A-DQ(ZN)2Y Mini T 2x12E9/125 blue Art. No A-DQ(ZN)2Y Mini T 4x12E9/125 red Art. No A-DQ(ZN)2Y Mini T 6x12E9/125 violet Art. No A-DQ(ZN)2Y Mini T 8x12E9/125 pink Art. No A-DQ(ZN)2Y Mini T 12x12E9/125 grey Art. No Type number of number of tubes tube-ø tensile strength outer-ø weight fibers + fillers approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y Mini T 2x12E9/125 blue , ,6 29,1 A-DQ(ZN)2Y Mini T 4x12E9/125 red , ,6 30,0 A-DQ(ZN)2Y Mini T 6x12E9/125 violet , ,6 30,8 A-DQ(ZN)2Y Mini T 8x12E9/125 pink , ,5 44,5 A-DQ(ZN)2Y Mini T 12x12E9/125 grey , ,5 64,1 Stranded mini tube cable for laying into micro ducts. This cable is used in access networks as both connection between fiber distributers and house connection for multi dwelling units. Fibers according ITU-T G.657.A1. Due to both the deployed fibers and its light construction it is suitable for small bending radii. Construction central member, metal free loose buffer tube filled with a thixotropic gel, swellable aramid yarns dry filled cable core rip cord PE-sheath Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise Tube colours 1: red 2: green others: nature or white Filler colours black Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: according to IEC E1 compressive strength: according to IEC E3 value: 1000 N/10 cm impact strength: according to IEC E4 value: 5 Nm (3 impacts, 300 mm hammer radius) min. bending radius: according to IEC E11 values: static R = 10 x D, dynamic R = 20 x D (cable outer diameter) temperature range: according to IEC F1 storage and transport -30 C up to +60 C laying -5 C up to +50 C operation -30 C up to +60 C water penetration: according to IEC F5 value: 1 m (0,1 bar, 24 h) OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 9

10 A-DQ(ZN)2Y Mini CT - Mini cable, central unitube, D30-S04 outdoor cable metal-free longitudinally water-tight A-DQ(ZN)2Y Mini CT 12E9/125 yellow Art. No A-DQ(ZN)2Y Mini CT 24E9/125 blue Art. No Type number of number of tube-ø Zugfestigkeit outer-ø weight fibers/tube fibers approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y Mini CT 12E9/125 yellow , ,9 12,9 A-DQ(ZN)2Y Mini CT 24E9/125 blue , ,9 13,8 Central mini tube cable for laying into micro ducts. This cable is used in access networks as drop cable to house connections. Fibers according ITU-T G.657.A1. Due to both the deployed fibers and its light construction it is suitable for small bending radii. Construction center unitube strength members (aramide yarns) PE-sheath Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colour red Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: min. bending radius: temperature range: according to IEC E1 according to IEC E3 value: 1000 N/10 cm according to IEC E4 value: 1 Nm (3 impacts, 300 mm Hammer radius) according to IEC E11 value: static R = 20 x D (cable outer diameter) according to IEC F1 storage and transport -30 C up to +70 C laying -5 C up to +50 C operation -20 C up to +70 C

11 I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable - Inhouse cable, V06 inhouse cable metal-free halogenfree, flame retardant I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable Art. No Type number of tube-ø number of tubes tensile strength *) outer-ø weight fibers approx. µm + fillers max. N approx. mm approx. kg/km I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable ,5 *) with reversible attenuation increase FTTH in-house cable, suitable for laying within buildings in both horizontal and vertical ways. This cable is suitable for direct assembling with connectors. Fibers according ITU-T G.657.A1. Construction 4 buffered fibers (silikon-coated, 600 microns) strength members (aramide yarns) FRNC-sheath according to IEC , UV-resistant Fiber colours red, green, yellow, blue Mantelfarbe grey Marking letter symbol of fiber type, meter marking, PENGG KABEL, year of manufacturing Technical Data standard: IEC tensile strength: according to IEC E1 compressive strength: according to IEC E3 value: 500 N/10 cm bending radius: static 15 x cable outer diameter dynamic 20 x cable outer diameter temperature range: storage and transport -25 C up to +70 C laying -5 C up to +50 C operation -5 C up to +50 C OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 11

12 Fiber optic enclosure SEC15 for max. 128 splices Description The SEC15 dome enclosure is particularly suitable for connecting fibre optic cables featuring a small number of fibres Enclosure for in-line connections and branch-offs Suitable for underground, duct, wall and pole/tower mounting Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement Storage of cut/uncut multi-fibre loose tubes Cable entries for max. 1 oval entry for 2x10-25 mm cables 3 entries for mm cables Splice cassettes (order separate) 8 x SK120S Degree of protection >IP68 Max. splice capacity Splice protection tube 128 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at the centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg Steel ball, 2 m fall, at the centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <240 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 2 kg Scope of delivery Base plate, dome, locking ring incl. snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation SEC15 for max. 128 splices Art. No

13 SEC23 Tubeless short for max. 288 / 432 splices Description Tubeless version suitable especially for Single Circuit (SC) and Single Element (SE). Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Tubeless laying of the fibres from entry to splice cassette In-line connection and branch-off enclosure Suitable for ground, duct, wall, pole and tower mounting Short version especially for manholes or cable ducts Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement An entry module permits fibre guidance to any desired cassette entry Cable entries for max. 1 oval entry for 2x10-25 mm cables 4 entries for mm cables 2 entries for mm cables Splice cassettes (order separate) 36 x SK123 (SE) or SK223 (SC) Available in cassette sets of 6 splice cassettes each max. 6 sets (3 units on either side). Splice cassettes engaged in a slanted position Pivoting splice cassettes (90 ) to provide easy access to each splice Degree of protection >IP68 Max. splice capacity 2x4 splices at each SK223 (SC) splices at each SK123 (SE) 432 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg steel ball, 2 m fall, centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <600 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 3.5 kg Scope of delivery Base plate, dome, locking ring with snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation, 2 entry modules incl. cover SEC23 Tubeless short for max. 288 / 432 splices Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 13

14 SEC23 Tubeless classic for max. 576 / 864 splices Description Tubeless version suitable especially for Single Circuit (SC) and Single Element (SE). Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Tubeless laying of the fibres from entry to splice cassette In-line connection and branch-off enclosure Suitable for ground, duct, wall, pole and tower mounting Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement An entry module permits fibre guidance to any desired cassette entry Cable entries for max. 1 oval entry for 2x10-25 mm cables 4 entries for mm cables 2 entries for mm cables Splice cassettes (order separate) 72 x SK123 (SE) or SK223 (SC) Available in cassette sets of 6 splice cassettes each ½ max. 12 sets (6 units on either side). Splice cassettes engaged in a slanted position Pivoting splice cassettes (90 ) to provide easy access to each splice Degree of protection >IP68 Max. splice capacity 2x4 splices at each SK223 (SC) splices at each SK123 (SE) 864 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg steel ball, 2 m fall, centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <600 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 4 kg Scope of delivery Base plate, dome, locking ring with snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation, 2 entry modules incl. cover SEC23 Tubeless classic for max. 576 / 864 splices Art. No

15 Fiber optic enclosures - accessories Cable entry sets (shrinking) Sealing set for standard connection bushes of the SEC 15 and SEC 23 versions For sealing cables with a PE-jacket Excellent tightness and mechanical strength Material: Cross-linked polyolefine, inside coated with thermoplastic adhesive Scope of delivery: Heat-shrinkable sleeve, emery cloth, cable cleaning cloth, cable tie wraps, installation material; 1 additional branch-off clamp coming with the oval cable entry set Oval cable entry set 2x10-20 mm Art. No Round cable entry set mm Art. No Round cable entry set mm Art. No Microtube entries As an alternative to the shrinking entries there are microduct launches 16/12 mm 14/10 mm, 12/8 mm available on request. Microtube entries on request Splice cassette SK120 á 16 splices Stripping dimensions (cm): Windings Min. Max With the possibility for mounting the hinge: Splice storage for all kinds of optical fibres Splice cassettes can be piled one on top of the other With or without the possibility for mounting the hinge Installation of different splice protection holders is possible through the snap-on system Laying in an 8-shaped loop is possible Bending radius: >30 mm Capacity Splices 16 splice protection tubes Ø 2.5 mm (heat-shrinkable) Splice protection holders 2x...-SRH8 Reserve fibre length approx. 40 m Material: Polystyrene Weight: 36 g Scope of delivery: 1 Splice cassette (excl. splice protection holder, excl. hinge) Without the possibility for mounting the hinge: Splice cassette SK120 á 16 splices Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 15

16 Splice cassette set SK123 6xSE á 12 splices The splice cassette set serves for guiding fibres from the entry module to the splice cassette and for splice storage of all kinds of optical fibres Installation of max. 6 splice cassette sets in the SEC23 Tubeless short enclosure and max. 12 splice cassette sets in the SEC23 Tubeless classic enclosure Cassette base plate with guiding channels for fibres and fastening options for a max. of 6 splice cassettes LWL-SK123 (SE) Versions for heat-shrinkable (splice protection tubes) Material: Polycarbonate VL94HB, colour RAL 9001 Weight: 0,3 kg Scope of delivery: 1 cassette base plate, 6 LWL-SK123 splice cassettes Splice cassette set SK123 6xSE á 12 splices Art. No Splice cassette set SK223 6xSC á 2x4 splices The splice cassette set serves for guiding fibres from the entry module to the splice cassette and for splice storage of all kinds of optical fibres Installation of max. 6 splice cassette sets in the SEC23 Tubeless short enclosure and max. 12 splice cassette sets in the SEC23 Tubeless classic enclosure Cassette base plate with guiding channels for fibres and fastening options for a max. of 6 splice cassettes LWL-SK223 (SC) Versions for heat-shrinkable (splice protection tubes) Material: Polycarbonate VL94HB, colour RAL 9001 Weight: 0,47 kg Scope of delivery: 1 cassette base plate, 6 LWL-SK223 splice cassettes Splice cassette set SK223 6xSC á 2x4 splices Art. No Wall-mounting set for SEC15, SEC23 Fastening angle for convenient wall-mounting Material: Powder-coated 3-mm aluminium sheet, RAL 7035 Scope of delivery: Wall-mounting set SEC23 SEC15 SEC23 Short Wall-mounting set for SEC 15 Art. No Wall-mounting set for SEC 23 Art. No

17 Outdoor cabinet KVZ F5 1080/320 OPDISYS Technical characteristics: Material housing and base polycarbonate Color housing and base RAL 7038 Protection class IP54 Capacity of fiber modules 16 OPDISYS Modules (16HU) at a housing size (WxHxD) 998 x 754 x 310 Gas blocker permanently integrated Door with swivel handle, prepared for two half profile cylinder Fiber optic fixing kit made of stainless steel KVZ F5 1080/320 OPDISYS Art. No Fiber module 24 LC/APC, 1HU Art. No Fiber module 24 E2000/APC, 1HU Art. No Fiber module 12 SC/APC, 1HU Art. No Fiber module for up to 48 splices, 1HU Art. No KVZ small as splicing version - equipped with 2x6 splice cassettes sets of SEC23 on request OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 17

18 Cable manhole EK 428 LW 800x1400 Low weight An advantage when transporting and handling. Easy delivery to inaccessible sites, such as along railway lines or inner-city areas Minimal installation effort No heavy transporters or cranes required Modular construction Manhole depths and connection positions are variable by means of the combination of framework modules Superstructure about existing pipe extrusion lines Without any difficulty bonding of existing pipeline alignment through open side parts in connection with the accessory Through the low weight the bonding is acutely easy Practical product Infinitely variable height and angle compensation Exact-fit pipe connections by means of set break points Sealing elements for cables without tubing Stability High degree of stability with low inherent weight, resulting from the use of high-quality plastic Optimum embedding in the surrounding soil Mechanical protection of the top edge provided by hot-dip galvanised steel frame Material For all load-bearing elements made of plastic: Modified polycarbonate (PC) High temperature resistance Surface finish not critical affected by hot or melted asphalt High degree of stability Fireproof Corrosion-proof Highly resistant to chemicals Highly resistant to UV light and weathering Recyclable several times over

19 Fittings Up to 2 sleeves (SEC15 or SEC23) for direct buried fiber optic cables or micro tubes with swiveling telescopic sleeve holder for a optimum working position Manhole cover Manhole cover in various versions: Cast iron (with lock) - D400 (400 kn testing force) Steel filled with concrete (with lock) - D400 (400 kn testing force) Bulb plate (with screwed) - A15 (15 kn testing force) Accessories Under cover fuse for protection against damage to the fittings Monitoring system for central monitoring of access Dimensions and test classes clear dimension: 800 x 1400 mm External height: 935 mm Test class: D400 and A15 EK 428 LW 800x1400 with cast iron cover (consisting of 4 parts) Art. No EK 428 LW 800x1400 with bulb plate cover (consisting of 3 parts) Art. No EK 428 LW 800x1400 with steel cover on request Telescopic sleeve holder Art. No Other manhole types on request OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 19

20 House lead-in EK 459 for micro-tubes, gas-tight This house lead is specially designed for the sealing of fiber optic cable in the introduction in building walls. It is suitable for all wall types (DIN 1819T.4) as suitable for foundations made of waterproof concrete. The foaming principle guarantees a perfect seal. Technical characteristics: Required bore diameter of only 40 mm Cover a large range of diameters of m micro-tubes: 7-14 mm single introduction and 7 mm double insertion Wall thickness: 400 mm standard, others upon request Delivery option for micro-tube diameters from 2 to 8 mm Gas-tight and waterproof up to 4 m water column Due to funnel-shaped silicone sealing discs technology only minimum effort pushing in the micro-tube / fiber optic cable, therefore no risk of kinking the line About quick-grid-screw flange permanent pressing of the plastic sealing bead (outside of building) Fast and gentle on the material sealing the micro-tubes / fiber optic cables EK 459 for micro-tubes, gas-tight, for wall thicknesses up to 400 mm Art. No Other house lead-in on request

21 Microtube Micro tubes are made of high density polyethylene (HDPE) and Silicore (super smooth inner surface, co-extruded with HDPE, allows higher injection and retraction speeds and lengths) were prepared and used to protect optical fiber cable. Inner surface is made from permanent sliding material Silicore with a very low coefficient of friction and standardly with fine ribs. Outer microduct s surface is smooth. Microduct is not designed for permanent inner pressure. Microduct does not contain dangerous chemicals in accordance to the Directive 2006/1907/EC (REACH). Microduct meets requirements of the Directive 2002/95/EC (RoHS) - content of lead, cadmium, mercury, Cr VI, PBB und PBDE. General specification Parameter Value Standard, conditions Ovality max. 5% Internal standard, before coiling Inner coefficient of friction max. 0,1 Internal standard Visual examination free from defects Internal standard Crush - pressure force min N EN , E3, sample 200 mm, aktive 100 mm, ID deformation by 15%, speed 3 mm/min. Impact no damage after the test, dimens. in tolerances after recovery EN , method E4, striking surface radius 10 mm, impact energy 15 J, recovery time 1 h Thermal expansion 1, K 1 ISO , temperature range from -20 C to +70 C Longitudinal reversion max. 3% EN ISO 2505, oven, 110 C, 60 min. Transport and storage temperatures from -40 C to +70 C - Installation temperatures from -10 C to +50 C - Operating temperatures from -40 C to +70 C - Blowing pressure max. 20 bar max. 2 hours at max. +50 C Outdoor exposure (central eurpope conditions) max. 12 months - Microduct DB 7/4 - recommended cable outer diameter from 1,0 to 2,5 mm Parameter Value Standard, conditions Outer diameter (OD) 7±0,1 mm Internal standard Inner diameter (ID) min. 3,9 mm Internal standard Wall thickness (WT) min. 1,4 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 3,5 mm Burst pressure min. 70 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,1 mm EN , E3, sample 200 mm, aktive 100 mm, force 1718 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,04 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 4,7 - Weight 25 kg/km - Installation tensile force max. 350 N - Minimum bending 70 mm - OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 21

22 Microduct DB 10/6 - recommended cable outer diameter from 2,0 to 4,5 mm Parameter Value Standard, conditions Outer diameter (OD) 10±0,1 mm Internal standard Inner diameter (ID) min. 5,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 5,0 mm Burst pressure min. 70 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,5 mm EN , E3, sample 200 mm, aktive 100 mm, force 2100 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,19 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 5 - Weight 47,5 kg/km - Installation tensile force max. 680 N - Minimum bending 100 mm - Microduct DB 12/8 - recommended cable outer diameter from 4,0 to 6,5 mm Parameter Value Standard, conditions Outer diameter (OD) 12±0,1 mm Internal standard Inner diameter (ID) min. 7,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 6,5 mm Burst pressure min. 60 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,8 mm EN , E3, sample 200 mm, aktive 100 mm, force 1680 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,36 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 6 - Weight 59 kg/km - Installation tensile force max. 840 N - Minimum bending 120 mm - Microduct DB 14/10 - recommended cable outer diameter from 5,0 to 8,5 mm Parameter Value Standard, conditions Outer diameter (OD) 14±0,1 mm Internal standard Inner diameter (ID) min. 9,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 8,0 mm Burst pressure min. 50 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 2,1 mm EN , E3, sample 200 mm, aktive 100 mm, force 1400 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,61 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 7 - Weight 72 kg/km - Installation tensile force max N - Minimum bending 140 mm - Microduct DB 16/12 - recommended cable outer diameter from 7,0 to 10,0 mm Parameter Value Standard, conditions Outer diameter (OD) 16±0,1 mm Internal standard Inner diameter (ID) min. 11,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 10,0 mm Burst pressure min. 40 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 2,4 mm EN , E3, sample 200 mm, aktive 100 mm, force 1200 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,94 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 8 - Weight 84 kg/km - Installation tensile force max N - Minimum bending 160 mm - Microduct 7/4 (for cables from 1,0-2,5 mm) Art. No Microduct 10/6 (for cables from 2,0-4,5 mm) Art. No Microduct 12/8 (for cables from 4,0-6,5 mm) Art. No Microduct 14/10 (for cables from 5,0-8,5 mm) Art. No Microduct 16/12 (for cables from 7,0-10,0 mm) Art. No

23 Metal free micro duct connector Body material: Polyamide Spring material: Polyacetal Seal material: NBR Temperature range: -20 C to +50 C Working pressure: max. 20 bar Lifespan: 25 years Standards: EN Available sizes (Dimension length / width / through bore / tensile force [N]) Connector for microducts 7/3.5 mm 42 / 17 / 3.5 / 150 N Connector for microducts 10/5.5 mm 48 / 20.5 / 5.5 / 250 N Connector for microducts 12/8 mm 52 / 23 / 8.0 / 530 N Connector for microducts 14/10 mm 60 / 25.5 / 10.0 / 1000 N Connector for microducts 16/12 mm 67 / 30 /12.0 / 1500 N Metal free micro duct connector 7 mm Art. No Metal free micro duct connector 10 mm Art. No Metal free micro duct connector 12 mm Art. No Metal free micro duct connector 14 mm Art. No Metal free micro duct connector 16 mm Art. No Metal free end stop Body material: Polyamide Spring material: Polyacetal Seal material: NBR Temperature range: -20 C to +50 C Impact resistance: N Working pressure: max. 20 bar Lifespan: 25 years Standards: EN Available sizes (Dimension length / width / tensile force [N]) End stop for 7 mm microducts 23 / 17.0 / 80 N End stop for 10 mm microducts 26 / 20.5 / 150 N End stop for 12 mm microducts 28 / 23.0 / 200 N End stop for 14 mm microducts 33 / 25.5 / 300 N End stop for 16 mm microducts 36.5 / 30.0 / 400N Metal free micro duct end stop 7 mm Art. No Metal free micro duct end stop 10 mm Art. No Metal free micro duct end stop 12 mm Art. No Metal free micro duct end stop 14 mm Art. No Metal free micro duct end stop 16 mm Art. No Divisible gasblock Body material: Seal material: Gas seal pressure: reinforced glassfiber polyamid TPE 0,5 bar Divisible gasblock 7 (for 2,5 mm cables) Divisible gasblock 10 (for cables from 2,5-3,9 mm) Divisible gasblock 12 (for cables from 5,6-6,5 mm) Divisible gasblock 14 (for 8,5 mm cable) Divisible gasblock 16 (for 8,5 mm cable) Art. No Art. No Art. No Art. No Art. No Microduct cutter and deburring tool For clean and safe construction of the microduct network, we recommend that you use the appropriate tools: Microduct cutter 4-12 mm Microduct shear 4-28 mm Deburring tool Microduct shear 4-28 mm Art. No Microduct cutter 4-12 mm Art. No Deburring tool Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 23

24 Interconnect case OM10 BEP The distribution enclosure serves as a termination for fiber optic cable to connector and for storing from splicing for max. 8 customers fibers (1 household) Small termination box, especially suitable where space is limited Suitable for indoor wall-mounting and installation in moist rooms Pull-out splice storage frame with splice protection holders Installation point for strain relief element (Kevlar) Provides sufficient space for multi-fibre loose tube reserves under the splice storage frame Entries Multi entry for 3 x I-VQ(ZN)H cable and PG9 cable gland Splice protection holder 1 SRH8 or 1 SWH12 Degree of protection of the empty enclosure IP54 Material Enclosure Polystyrene, similar to RAL 7035 Splice storage frame Powder-coated aluminium, RAL 7035 PG Cable entry gland Plastic Weight Approx. 0.7 kg Scope of delivery 1 Enclosure, 1 splice storage frame, 1 copy of Instructions for Installation, 1 PG9-cable gland, 2 cable tie wraps, 2 pigtail clips PC121, 1 SRH8/SWH12 splice protection holder OM10 BEP for max. 8 customer fibers (1 household), incl. 1 Stk. splice storage frame Art. No

25 RGV20 BEP The interconnect case RGV 20 BEP is used for distribution of the fibers in multiple dwellings to the specific house cabling for max. 96 customer fibers. The tubeless version is particularly suitable for Single Circuit (SC) and Single Element (SE) Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Single Element: For multi-fibre loose tube management (multi-fibre loose tube upon multi-fibre loose tube) Tubeless laying of fibres from the entry to the splice cassette Enclosure for in-line connections and branch-offs Suitable for wall mounting Door is right-hinged and easy to remove Clip-down handle Door sealing inside Degree of protection IP 54 with PG cable entry Strain relief points for central strength member and Kevlar reinforcement Storage area for cut/uncut multi-fibre loose tubes The removable cassette-ground plate is used for fastening the multi-fibre loose tubes and also for assembling the splice cassette sets onto the mounting plate The entry module permits fibre routing to any cassette entry Cable entries PG cable entries Ø 8-10 mm (PG11) Ø mm (PG13) Ø mm (PG16) Ø mm (PG21) 24x Ø 3 mm (PG29) for I-VQ(ZN)H 12 x SK123 (SE) or SK223 (SC) Splice cassettes Available as sets of 6 splice cassettes each => max. 2 sets Splice cassettes are engaged in a slanted position Swing-type splice cassettes (90 ) provide easy access to each splice Permanent temperature Max. 150 C Material Enclosure Thermoformed, self-extinguishing, halogen-free, glass-fibre reinforced polyester, colour RAL 7035 Mounting-, Base plate Powder-coated sheet steel, RAL 7035 Patch-, Fastening angle Powder-coated sheet steel, RAL 7011 Weight Approx. 5,1 kg Scope of delivery 1 Cabinet incl. door, clip-down handle and sealing, 1 mounting plate, 1 base plate, 1 entry module with cover, 1 fastening angle, 1 Angle with holes, fastening screws 415 A 315 B 175 C RGV20 BEP basic casing empty Art. No RGV20 BEP for max. 48 customer fibers (11 households), incl. 1 splice cassettes set (see page 16) RGV20 BEP for max. 96 customer fibers (23 households), incl. 2 splice cassettes sets (see page 16) Art. No Art. No OTO ZT 2xLC/APC Fiber optic junction box for FTTH-inhouse cabling For surface wall mounting FTTH junction box for 1 to 4 fibers Consists of a metal mounting plate, a plastic housing with integrated fiber storage for cable and pigtail wires and integrated in the housing Shuttered 2x LC / APC adapters including pigtails Adapters with integrated laser protection Labeling field with transparent cover Color: white, similar to RAL 9010 Dimensions: 88x88x23 mm OTO ZT 2xLC/APC pigtails inserted - ready for splicing Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 25

26 Heat shrinkable fiber optic splice protector Outer shrink tube: transparent, both ends preshrunk to closing the gap between the two tubes Inner shrink tube: transparent EVA hot melt adhesive (Ethylene vinyl acetate) Stainless steel with rounded ends to avoid fiber damage Color transparent Operating temperature -45 C to +100 C Shrink temperature 110 C Tensile strength 18 MPa (acc. ASTM D2671) Ultimate elongation 700 % (acc. ASTM D2671) Density 0,94 g/cm3 (acc. ISO R1183D) Dielectric strength 25 kv/mm (acc. IEC 243) Dielectric constant 2,5 (acc. IEC 243) Longitudinal change ±5 % (acc. ASTM D2671) Marking Pengg_MM.JJJJ Type Outer shrink tube (shrunk) outer-ø D1 length L1 Inner shrink tube (unshrunk) outer-ø D2 length L2 pin-ø D3 Steel pin stainless length L3 SP/F25/2,5A 2,45 ±0,1mm 25 ±0,5mm 1,3 ±0,3mm 25 ±0,5mm 1,0 ±0,05mm 21 ±0,1mm SP/F45/2,5A 2,45 ±0,1mm 45 ±0,5mm 1,3 ±0,3mm 45 ±0,5mm 1,0 ±0,05mm 41 ±0,1mm Heat shrinkable fiber optic splice protector SP/F25/2,5A Heat shrinkable fiber optic splice protector SP/F45/2,5A Art. No Art. No Adapter LC/APC 8 duplex flange with shutter Adapter with flange or snap-on mounting with shutter Adapter LCdx/APC 8 duplex flange with shutter Art. No Fiber optic patch panel Designed to storage fiber optic cables and splicing cassettes Intended for installing in 19 rack system Enable fiber optic termination and distribution Model offered: Resetable and sliding Installation depth: 250 mm Material: steel Powder coated Colour: RAL 7035 (Light Grey) - other colours on request Universal splice cassette holding system: fixed & booklet mounting option Equipped with removable splice cassette holder and antitwist system By default with 1 or 6 duplex adapters and pigtails 19 Fiber optic patch panel 24/1LCdx/APC 8 SM 1xPG16/1xAB RAL7035 complete Art. No Fiber optic patch panel 24/6LCdx/APC 8 SM 1xPG16/1xAB RAL7035 complete Art. No

27 Fiber-Pigtail Pigtails with optical fiber (600 µm acrylate buffer) and LC/APC8 connector Description of LC/APC simplex: user-friendly audible latch to indicate proper mating push-pull locking plastic housing with zirconia ferrule standard IEC insertion loss (IL) for SM (typical) mean value < 0.15 db (to reference connector) max. value < 0.30 db (to reference connector) return loss (RL) > 65 db 8 SM-Angle (APC) polishing PT LC/APC8 1E9/125/600/rt 1m for OTO Art. No PT LC/APC8 1E9/125/600/gn 1m for OTO Art. No PT LC/APC8 1E9/125/600/ge 1m for OTO Art. No PT LC/APC8 1E9/125/600/bl 1m for OTO Art. No PT LC/APC8 1E9/125/600/rt 2m for patch panel Art. No PT LC/APC8 1E9/125/600/gn 2m for patch panel Art. No PT LC/APC8 1E9/125/600/ge 2m for patch panel Art. No PT LC/APC8 1E9/125/600/bl 2m for patch panel Art. No FTTH in-house cable, installation cable on a cardboard reel I-VQ(ZN)H 4E9/125 FTTH in house cable preassembled with 2 LC/APC 8 connectors PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 27

28 Fiber optic cables Fiber optic passive components Fiber optic installation services Fiber to the home - solutions Telecommunication cables Railway cables Copper cable installation services PENGG KABEL GmbH Plant Optic Breitenfeldgasse Sankt Barbara Plant Copper Mariazellerstraße Kapfenberg Tel.: / Fax.: / info@penggkabel.at

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length}

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length} Description 24x SM G.657.A1 (6x4) The Loose Tube Cable Slim Rodent-Protected () is a non-metallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force.

More information

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH MEMBER (FRP + Glass yarns) -

More information

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE ( Micro loose tube cable ) WITH - SINGLE MODE OPTICAL FIBER (ITU-T G.652D, LWPF) - MICRO LOOSE TUBE (JELLY FILLED) - DRY CORE DESIGN - NON-METALLIC STRENGTH

More information

Product overview. Product characteristics. Article number Cables - Universal Print Date

Product overview. Product characteristics.   Article number Cables - Universal Print Date 77824 Article number 77824 Group Cables - Universal Print Date 24-10-2016 Product overview The ACE universal optical fibre cables are suitable for both indoor and outdoor situations. These cables offer

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

PO Box Riyadh Kingdom of Saudi Arabia. Tel: / , Fax: Website:

PO Box Riyadh Kingdom of Saudi Arabia. Tel: / , Fax: Website: PO Box 325934 Riyadh 11371 Kingdom of Saudi Arabia Tel: +966 11 4004718 / 4009204, Fax: +966 11 4008027 Website: www.amwajfactory.com E-mail: sales@amwajfactory.com info@amwajfactory.com MSHD-ATC-FDT Series

More information

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction Pipeline Accessories PSI Wall Sleeves General Information Selection Guide Technical Data Installation Instruction 1 PSI Wall Sleeves made of steel General Information An economic method to seal hydrostatically

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

GMRT. Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection

GMRT. Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection GMRT Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count

More information

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE 1. GENERAL DESCRIPTION 1.1 SCOPE This specification covers the design and performance requirements for the supply of optical fiber cable which

More information

RN Optical Termination Panel (RN OTP)

RN Optical Termination Panel (RN OTP) RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.

More information

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE 1. GENERAL DESCRIPTION 1.1 SCOPE This specification covers the design and performance requirements for the supply of optical fiber

More information

SPECIFICATION OPTICAL TERMINATION PANEL

SPECIFICATION OPTICAL TERMINATION PANEL SPECIFICATION OPTICAL TERMINATION PANEL Model Spec. No. VSOF-OTP-H VSS-0809-OTP-H-01A/SD Quality Assurance Team Distribution Depts. Manufacturing Division Sales Division Management Division Revision 09.

More information

InstaPATCH Plus Fiber System

InstaPATCH Plus Fiber System Fiber System Trunk Cables Equipment and Cross-Connect Cords Ruggedized Fanout Cables Modular and High- Density Shelves The SYSTIMAX System features a high-density, factory terminated, factory tested, modular

More information

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts This Specification is property of SEC and subject to change or modification without any notice Page 1 of 17 CONTENTS Clause Page 1 GENERAL 4 1.1 Scope

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

OptiLine 70. Service Poles. Technical and Material data

OptiLine 70. Service Poles. Technical and Material data P9 P97 P97 Description is a service pole range for all types of. Service poles are made of natural anodized aluminium with a high surface fi nish. They are installed free-standing in the room, mounted

More information

Fiber Optic Cables. General cable specification

Fiber Optic Cables. General cable specification Fiber Optic Cables General cable specification CONTENT CODING OF FIBER OPTIC CABLES ACCORDING TO THE VDE 0888 COLOUR CODING CHARTS SINGLE-MODE FIBER ITU-T G.652.D BEND INSENSITIVE SINGLE-MODE FIBER ITU-T

More information

3M Optical Fiber Cable Specification

3M Optical Fiber Cable Specification 3 3M Optical Fiber Cable Specification 1(2)-Fiber/Bending Insensitive/Low Water Peak Single-mode Fiber/Tight Jacket Indoor FRP Cable (Indoor Application) 2008-05 1 General This specification covers the

More information

TRITEC light Steel Panel Formwork

TRITEC light Steel Panel Formwork TRITEC light Steel Panel Formwork Perfection made in Germany Various practical illustrations of TRITEC Panel Combinations Guaranteed the largest possible range of sizes with the least possible amount of

More information

IP68 Quick connection system. IP68 Quick connection system

IP68 Quick connection system. IP68 Quick connection system IP68 Quick connection system IP68 Quick connection system Woertz IP 3G2.5 mm 2 and Woertz IP 3G4 mm 2 A high protection degree, short installation procedures, easy handling and expansion possibilities

More information

Product Datasheet. Fire Hose Reel (Page 3)

Product Datasheet. Fire Hose Reel (Page 3) Product Datasheet Fire (Page 2) Fire Hose Reel (Page 3) Flush Type Hose Reel Cabinet (Page 4) GRP Fire cabinets are used for indoor and outdoor application with weatherproof and antistatic properties,

More information

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 04 05 PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Over floor trunking 0 300 9 0 300 93 0 38 00 Conform to standard EN 50085-- For creating a link between trunking, column,

More information

Microducting Network Solutions. FTTx SYSTEMS. Microtubing Network Solutions. MiniGlide & MicroGlide Optical Fibre Tubing Systems

Microducting Network Solutions. FTTx SYSTEMS. Microtubing Network Solutions. MiniGlide & MicroGlide Optical Fibre Tubing Systems Microducting Network Solutions FTTx SYSTEMS Microtubing Network Solutions MiniGlide & MicroGlide Optical Fibre Tubing Systems System Overview The smart choice for smart networks A thirst for Ultra Broadband...

More information

FIBER OPTIC SPLICE CLOSURE

FIBER OPTIC SPLICE CLOSURE SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-MN401A VSS-0911-OFC-01A Quality Assurance Team Manufacturing Division Sales Division Management Division Revision 09. 11

More information

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks

More information

Enclosures for fibre optical networks. Elogic Systems offers insight, experience and a wide range of solutions

Enclosures for fibre optical networks. Elogic Systems offers insight, experience and a wide range of solutions Enclosures for fibre optical networks Elogic Systems offers insight, experience and a wide range of solutions A wide range of solutions developed for fibre optical networks Insight, experience and a wide

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

Telecommunications Infrastructure

Telecommunications Infrastructure Telecommunications Infrastructure Table of Contents Contents 1. INTRODUCTION... 2 2. DUCTING CAPACITY... 3 3. SUB DUCT SIZING... 4 4. DUCTING AND SUB DUCTING CONSTRUCTION AND COLOUR... 5 5. BUILDING ENTRANCE:...

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

Stack Parking Surface Mounted Stackers

Stack Parking Surface Mounted Stackers 1 / 6 Stack Parking Surface Mounted Stackers swiss-park V-2 Comfort The V-2 is designed to park cars of any size thanks to its vertical adjustability. It will accommodate cars as tall as the garage ceiling

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT Page 220548-1 SECTION 220548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

HDPE Conduit Specification 2011

HDPE Conduit Specification 2011 General This specification covers the minimum requirements for HDPE conduit and is based on ASTM F 2160. HDPE Conduit is for use primarily in underground applications as conduit, innerduct, direct buried

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT Page 230548-1 SECTION 230548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS General All Materials shall be EN, ISO or equivalent standard and shall be supplied from approved manufacturers. According to the International

More information

Welcome to the market leader for state-of-the-art micro duct systems

Welcome to the market leader for state-of-the-art micro duct systems Welcome to the market leader for state-of-the-art micro duct systems Dear gabocom customers and partners Cordial thanks for your interest in our products and systems. Before familiarizing you with these

More information

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

UTILUX CABLE MANAGEMENT

UTILUX CABLE MANAGEMENT Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. UTILUX CABLE

More information

Ducts and Microducts HDPE PIPES FOR FIBER OPTIC & CABLE PROTECTION

Ducts and Microducts HDPE PIPES FOR FIBER OPTIC & CABLE PROTECTION Ducts and Microducts HDPE PIPES FOR FIBER OPTIC & CABLE PROTECTION WHO ARE WE? Hebeish Group is the mother company of 4 subsidiary companies, completing each other to provide our customer with full HDPE

More information

Dagard-Taïga/UK 28/02/02 11:50 Page 1 aïga Cold Room T

Dagard-Taïga/UK 28/02/02 11:50 Page 1 aïga Cold Room T Taïga Cold Room Taiga is designed for the storage of perishables, in the retail, catering and supermarket sectors The various environmental and operating requirements (ceiling height, type of premises,

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

R-LOC Stainless Steel Products

R-LOC Stainless Steel Products R-LOC Heritage R-LOC Signals Telecom Sub-Sea Utilities Power Gen Oil & Gas Shipping & Cargo Transportation Military Introduction Page 1 Heritage Page 2 Table of Content Page 3 R-LOC Technology Page 4 Ball

More information

13-SDMS-04 REV. 00 SPECIFICATIONS FOR NON-METALLIC, LOOSE TUBE, DUCT & BLOWN TYPE FIBER OPTIC CABLE

13-SDMS-04 REV. 00 SPECIFICATIONS FOR NON-METALLIC, LOOSE TUBE, DUCT & BLOWN TYPE FIBER OPTIC CABLE 13-SDMS-04 REV. 00 SPECIFICATIONS FOR NON-METALLIC, LOOSE TUBE, DUCT & BLOWN TYPE FIBER OPTIC CABLE This specification is property of SEC and subject to change or modification without any notice. Page

More information

ITEM NO SABS SECTION 1 : PRELIMINARY AND GENERAL 1200 A FIXED-CHARGE ITEMS Contractual Requirements Sum 1.0 -

ITEM NO SABS SECTION 1 : PRELIMINARY AND GENERAL 1200 A FIXED-CHARGE ITEMS Contractual Requirements Sum 1.0 - 1 SABS 1200 A SECTION 1 : PRELIMINARY AND GENERAL SECTION 1: PRELIMINARY & GENERAL PAYMENT DESCRIPTION UNIT QUANTITIES RATE AMOUNT 1.1 8.3 FIXEDCHARGE S 1.1.1 8.3.1 Contractual Requirements 8.3.2 Establish

More information

TECHNICAL DATA SHEET GRILON TS V0

TECHNICAL DATA SHEET GRILON TS V0 TECHNICAL DATA SHEET GRILON TS V0 General product description Grilon TS V0 is an unreinforced, normal viscosity, self-extinguishing PA66 + PA6 injection moulding grade. Grilon TS V0 has the following important

More information

VERTICALLY MOUNTED S210 BLOCKS (page 7.7) S210 TOWER SYSTEM (pages ) Mounting Options Wall 89D Bracket Wall 19 inch Rack 23 or 35 inch Frame

VERTICALLY MOUNTED S210 BLOCKS (page 7.7) S210 TOWER SYSTEM (pages ) Mounting Options Wall 89D Bracket Wall 19 inch Rack 23 or 35 inch Frame PRODUCTS CONNECTION SYSTEM (pages 7.2 7.7) VERTICALLY MOUNTED BLOCKS (page 7.7) TOWER SYSTEM (pages 7.4 7.5) FIELD TERMINATED 19 INCH PANELS (pages 7.6 7.7) XLBET FRAMES (pages 8.8 8.9) Racks Product Stard

More information

Conergy SolarFamulus II

Conergy SolarFamulus II Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use

More information

fiber optic cables fibrain

fiber optic cables fibrain fiber optic cables fibrain content Information Application FOC Parameters Low Loss SM/MM Bendsafe Fiber and Cables Information Fiber Identification Page Page Page 6 Page 7 Page 8 Page 9 Page 0 DATACOM

More information

Fiberstrut Parts Catalogue

Fiberstrut Parts Catalogue Fiberstrut s Catalogue 1 Technical Information Fiberstrut Fabrication The installation of fiberglass channels and accessories is similar to the installation of metallic channels and accessories. All standard

More information

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 1 st Edition LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially superior quick

More information

OPTICAL FIBRE CABLE PERFORMANCE

OPTICAL FIBRE CABLE PERFORMANCE WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm

More information

Kaf-Tech Product Specification

Kaf-Tech Product Specification Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-LUMINARY CABLE

More information

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System 2004 Specifications Houston District SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System 1. Description. Furnish and place a Multi-Duct Conduit (MDC) system that is suitable for installation in an outdoor

More information

Standard program overview fire doors

Standard program overview fire doors Fire doors Standard program overview fire doors Fire-resistant and fire-proof steel doors Product Dimensions in mm width/height (clear opening) Tested as fire-resistant door in acc. with DIN 4102 / EN

More information

ARINC 801 Fiber Optic Connectors

ARINC 801 Fiber Optic Connectors ARINC 801 Termini and 38999 Connectors ARINC 801 Fiber Optic Connectors The high density fiber optic connection made by SOURIAU using 1.25mm ferrules. A qualified technology Flight proven qualified ARINC

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange

PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange Pipeline Accessories PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange General Information Sectional View Technical Data 1 PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange General

More information

NETbox Wall Mounting CABINETs

NETbox Wall Mounting CABINETs NETbox Wall Mounting CABINETs 9 NETbox Wall Mounting Cabinets FAMILY W=mm NETbox Series Wall Mounting Cabinets NETbox series Networking Enclosures/ Cabinets, provide maximum optimization resulted to an

More information

SPECIAL SPECIFICATION 1663 Fiber Optic Cable

SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1993 Specifications CSJ 0192-01-080 SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1. Description. This Item shall govern for the furnishing and installation of fiber optic cable in designated locations

More information

50 N E T b o x Wall Mounting C A B I N E T s

50   N E T b o x Wall Mounting C A B I N E T s 50 www.lande.com.tr N E T b o x Wall Mounting C A B I N E T s W=600mm NETbox Series Wall Mounting Cabinets NETbox series Networking Enclosures/ Cabinets, provide maximum optimization resulted to an optimum

More information

TECHNICAL BULLETIN SPECIFICATIONS FOR MICRODUCT AND FUTUREPATH

TECHNICAL BULLETIN SPECIFICATIONS FOR MICRODUCT AND FUTUREPATH TECHNICAL BULLETIN CONTENTS: SPECIFICATIONS FOR MICRODUCT AND FUTUREPATH 1.0 General Information 2.0 Quality 3.0 Product Design 4.0 Material Requirements 5.0 Dimensions and Tolerances 6.0 Performance Requirements

More information

BOXES - CONSUMER UNITS

BOXES - CONSUMER UNITS BOXES - CONSUMER UNITS ISOBOX Flush mounting boxes - For masonry Technical specifications technopolymer highly resistant to impacts and to deformation temperature during installation: from -15 C to +60

More information

Panel elements. Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements

Panel elements. Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements Panel elements Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements Panel elements Products in this section Acrylic Glass Polycarbonate PET-G Sheet Material

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

SGL2100 Sliding Systems

SGL2100 Sliding Systems SGL2100 Sliding Systems High Performance Thermally Broken Sliding System Reference Brand: Sapa Building System Confort 160 Lift and slide GENERAL DESCRIPTION Thermally insulated sliding door system with

More information

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE Blast Resistant Enhanced Curtain Wall Blast Resistant Enhanced Curtain Wall Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

DUCTING HOSES WORM DRIVE CLAMPS AND CONNECTORS RESISTANT TO ABRASION RESISTANT TO HIGH TEMPERATURE RESISTANT TO CHEMICALS SPECIAL

DUCTING HOSES WORM DRIVE CLAMPS AND CONNECTORS RESISTANT TO ABRASION RESISTANT TO HIGH TEMPERATURE RESISTANT TO CHEMICALS SPECIAL DUCTING HOSES WORM DRIVE CLAMPS AND CONNECTORS RESISTANT TO ABRASION RESISTANT TO HIGH TEMPERATURE RESISTANT TO CHEMICALS SPECIAL RESISTANT TO ABRASION Light, flexible ducting hoses made of polyurethane,

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm DATASHEET - CI45E-200-RAL7032 Delivery program Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm Part no. CI45E-200-RAL7032 Catalog No. 090160 EL-Nummer (Norway) 2502339 Dimensions mm Product

More information

LEADING IN WELDING SAFETY CATALOGUE 2014 CONSTRUCTION. Version 14/01

LEADING IN WELDING SAFETY CATALOGUE 2014 CONSTRUCTION. Version 14/01 LEADING IN WELDING SAFETY CATALOGUE 2014 CONSTRUCTION Version 14/01 CONSTRUCTION Table of contents TABLE OF CONTENTS General information 3 Quality 4 Swivel arms 5 Swivel arms supports 16 Poles 18 Columns

More information

GLENWOOD PLACE 2 MAR 2015

GLENWOOD PLACE 2 MAR 2015 PART 1 - GENERAL 1.01 SUMMARY: SECTION 16110 RACEWAYS A. Description: 1. Provide continuous conduit systems - beginning at the service point, to all distribution equipment and to every outlet and piece

More information

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm Large plastic pipe technology Large diameter pressure pipe up to DN/ID 5000 mm Powerful and designed according to YOUR specifications Large diameter pressure pipes No sagging and less wallthickness saves

More information

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE 1. SCOPE This schedule specifies requirements for the AquaSpira CSR (Composite Steel Reinforced) pipe system as manufactured by AquaSpira Limited. It is applicable for underground gravity drains, sewer

More information

New consumer units. Design and functionality in plain sight.

New consumer units. Design and functionality in plain sight. New consumer units. Design and functionality in plain sight. CONSUMER UNITS A wide range of stylish solutions for any type of masonry or plasterboard wall. Consumer unit with white blind cover Consumer

More information

Multigates made of ShieldLine Materials

Multigates made of ShieldLine Materials Trelleborg Moulded Components ChemLine FoodLine ShieldLine FrictionLine Multigates made of ShieldLine Materials IP66/67, IP65, IP55, IP54 Multigates Multigates are metal or plastic reinforced cable gland

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Contents. 3. Overview Pipe. 8. Fittings. 9. Features & benefits Installation considerations. 16. Jointing instructions

Contents. 3. Overview Pipe. 8. Fittings. 9. Features & benefits Installation considerations. 16. Jointing instructions TECHNICAL MANUAL Contents 3. Overview 4-7. Pipe 8. Fittings 9. Features & benefits 10-15. Installation considerations 16. Jointing instructions 17-22. Ezi Pex Push fitting 23. Warranty www.ezipex.com.au

More information

SOFC-DA-180KN-192 G652D

SOFC-DA-180KN-192 G652D Description The design of the offered cable has been a typical structure of submarine cables which is prevailing over the world and has been approved for stable performance in submarine cable system. Loose

More information

Quality from Finland

Quality from Finland Quality from Finland Fibre optic cables by Nestor Cables Table of contents Direct buried cables 4 FYOVD2PMU 5 FYO2PMU 6 FYO2PMU Mini 7 FYO2RMU 3,5kN 8 FZOMVDMU-SD 9 FZOVDMU-SD 10 FZVD2PMU Flex 11 FZ4RMU

More information

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing www.swagelok.com Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing Features 1/4 to in. and 6 to 12 tubing sizes available in 316/316L stainless steel and copper Seamless and welded tubing

More information

Termco Heatshrink.

Termco Heatshrink. Termco Heatshrink Thin Wall Tubing (Flame Retardant) Clear Thin Wall Tubing Green/Yellow Thin Wall Tubing Dual Wall Tubing Medium Wall Tubing Cable End Caps Heat Shrink Miniature End Cap Heat Shrinkable

More information

OETIKER. Technical Data Sheet. 1-Ear Clamps. 1-Ear Clamps with Insert. 2-Ear Clamps. Connecting Technology. Dimple. Ear. Ear width.

OETIKER. Technical Data Sheet. 1-Ear Clamps. 1-Ear Clamps with Insert. 2-Ear Clamps. Connecting Technology. Dimple. Ear. Ear width. OETIKER width Technical Data Sheet 1- Clamps Product Group 153 Insert width 1- Clamps with Insert Product Group 154 width (Double clamping range) 2- Clamps Product Group 101 & 151 Connecting Technology

More information

Design Standard Conduit for Electrical Systems

Design Standard Conduit for Electrical Systems Design Standard Purpose: This design standard has the purpose of creating a consistent application for the installation of conduits throughout the East Side Union High School District, therefore achieving

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

Technische Grundlagen

Technische Grundlagen Technische Grundlagen 47 Technical bases Technical bases for point drainage ACO bath drains are used in areas where there is a demand for functional long-life solutions with high flow volumes combined

More information

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Fiber Optic Panels. 1 st Edition

Fiber Optic Panels. 1 st Edition Fiber Optic Panels 1 st Edition Introduction Cable management is an essential consideration in any successful fiber communications network. The FMT series fiber optic panel enables termination, termination/splicing,

More information

This specification describes the minimum requirements for industrial thermal insulation.

This specification describes the minimum requirements for industrial thermal insulation. 016/09/7 1/7 1.0 PURPOSE This specification describes the minimum requirements for industrial thermal insulation. Read it in conjunction with the applicable insulation and insulation finish specifications

More information

LSA Connecting Technology. LSA Connecting Technology Distributor Cabinets and Boxes Accessories

LSA Connecting Technology.   LSA Connecting Technology Distributor Cabinets and Boxes Accessories LSA Connecting Technology www.efb-elektronik.de LSA Connecting Technology Distributor Cabinets and Boxes Accessories 224 225 Telecommunication LSA Terminal Blocks Range 1 LSA Connection Module 1/20 20pairs

More information

Section 5 Panels & Accessories

Section 5 Panels & Accessories Contents Section 5 Panels 74-76 Stiffener/Handle 79 Wire Mesh 75 Sliding Door Guide 80 Panel Mounting locks 77 Rolling Door Guide 81 Mesh Retainers 78 ifold Door Glide 82-83 Mesh Clamp 79 T-Clips 84 Panels

More information

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

SpotClip. Downlight covers for safe lighting installation in suspended ceilings SpotClip Downlight covers for safe lighting installation in suspended ceilings SpotClip is a unique and innovative range products for the safe and easy installation Our inhouse team of developers at HellermannTyton

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information