RICHFIELD CITY CONSTRUCTION STANDARDS

Size: px
Start display at page:

Download "RICHFIELD CITY CONSTRUCTION STANDARDS"

Transcription

1 CONSTRUCTION STANDARDS REVISED OCTOBER 2015 Jones & DeMille Engineering, Inc. [ ] 1535 South 100 West Richfield, UT Ph Fax South Highway 10 Price, UT Ph Fax

2 CONSTRUCTION STANDARDS The following standards shall apply to the design and construction of public works improvements for subdivisions and other developments within the Richfield City limits. A. Current (2007) edition of the Manual of Standard Specifications published by the Utah Chapter of the American Public Works Association (APWA) with the following modifications: 1. Current amendments published by the Utah Chapter of the APWA. 2. References to OWNER shall mean Richfield City and references to ENGINEER shall mean Richfield City s engineer. 3. Delete Document General Conditions. 4. Delete Section Summary of Work. 5. Delete Section Value Analysis. 6. Modify Section Product Options and Substitutions as follows: a) Article 1.1 Section Includes delete paragraph B. b) Article 1.2 Definitions delete paragraph B and its subparagraphs, and replace with the following: No substitutions are allowed. c) Delete Articles 1.3 through Delete Section Contract Modification Procedure. 8. Delete Section Payment Procedure. 9. Modify Section Preconstruction Conference as follows: a) Article 1.2 Preconstruction Conference, paragraph B delete subparagraphs 2 and 4. b) Article 1.2 Preconstruction Conference, paragraph C delete subparagraph 3 and delete and Change Orders at end of subparagraph Delete Section Partnering. 11. Delete Section Progress Schedule and replace with Supplemental Specification indicated below. 12. Modify Section Acceptance as follows: a) Article 1.3 Acceptance add paragraph E as follows: Acceptance testing will govern over quality control testing performed by Contractor. Acceptance testing does not relieve Contractor of responsibility for providing adequate quality control measures. 13. Modify Section Resident Superintendent as follows: a) Article 1.2 Qualifications delete paragraph D. 14. Modify Section Quality Control as follows: a) Part 1 General add article 1.8 as follows: 1.8 COORDINATE CONSTRUCTION STANDARDS A. Supplementary documents are essential parts of the construction standards and requirements occurring in one are binding as though occurring in all. Richfield City 1 Construction Standards

3 B. Governing ranking in case of discrepancy is: 1. Information: a. Project Construction Drawings and Specifications b. Supplemental Specifications c. Supplemental Drawings d. APWA Standard Specifications e. APWA Standard Drawings 2. Dimensions: a. Plan b. Calculated c. Scaled C. Notify Owner and Engineer promptly of any omissions or errors in contract so that necessary corrections and interpretations can be made. 15. Modify Section Traffic Control as follows: a) Article 1.3 Submittals change paragraph A to read as follows: Traffic control plan at least 10 days prior to starting work. b) Article 2.1 Pavement Markings, Signs, Barricades change paragraph A to read as follows: MUTCD. 16. Delete Section Owner-Furnished Products. 17. Modify Section Closeout Procedures as follows: a) Article 1.5 Closeout Submittals, paragraph C delete reference to Document b) Article 1.5 Closeout Submittals - delete paragraph D. 18. Modify Section Concrete Testing as follows: a) Article 1.6 Acceptance delete subparagraph B.2. b) Article 3.2 Cast-in-Place Products delete paragraph D. and H. 19. Modify Section Electrical Boxes and Fittings as follows: a) Article 2.3 Junction and Pull Boxes delete paragraph B and replace with the following: Buried Type: Polymer concrete box in accordance with ASTM C857, ASTM G154, ASTM D635 and ASTM D570. Coatings not required. Minimum size 15 inch wide by 25 inch long by 24 inch depth. 20. Modify Section Motor Controller as follows: a) Article 1.1 Section Includes, paragraph B add subparagraph 5 as follows: Variable-frequency drives. b) Part 2 Products add article 2.7 as follows: 2.7 Variable-Frequency Drives: A. Variable-frequency drive (VFD), single-phase or threephase, to adequately start and run motor. B. Provide main breaker, motor overload protection, overvoltage protection, and surge protection. C. Provide Hand-Off-Auto selector switch on cover with green pilot light for run indicator. VFD shall be programmed for all desired pump controls. D. Provide adequate ventilation for VFD case. Richfield City 2 Construction Standards

4 21. Modify Section Paving Asphalt as follows: a) Part 2 Products delete article Modify Section Asphalt Concrete as follows: a) Article 2.1 Paving Asphalt delete paragraph A and replace with the following: Asphalt: Performance graded asphalt binder in accordance with Section b) Article 2.4 Mix Design, paragraph A, - delete subparagraph 1.a and replace with the following: PG58-22: Light traffic pavement. c) Article 2.4 Mix Design, paragraph A, - delete subparagraph 1.b and replace with the following: PG58-22 or PG 64-34: Medium traffic pavement. 23. Delete Section Superpave. 24. Modify Section Copper Pipe as follows: a) Article 2.2 Connections, paragraph A delete Flared. 25. Modify Section Ductile Iron Pipe as follows: a) Article 2.1 Pipe and Fittings, paragraph A delete subparagraph 6. b) Article 2.2 Coverings, paragraph A delete and replace with the following: Buried Mechanical Joints: In areas with high water table, use stainless steel bolts and nuts. 26. Modify Section Polyethylene Pipe as follows: a) Article 2.1 Smooth Wall Pipe Systems - add paragraph E as follows: E. High density polyethylene pipe, in accordance with NSF-14 and AWWA C Iron Pipe Size: ASTM D2239, ¾ and 1 inch services. 2. Copper Tub Size: ASTM D2737, 1.5 and 2 inch services. 3. Working Pressure: 200 pounds per square inch. 4. Color: Blue. 5. Fittings: Bronze, compression fittings. 27. Modify Section Polyvinyl Chloride Pipe as follows: a) Article 2.2 Pressure Pipe Systems, paragraph A delete and replace with the following: Pipe: Conform to AWWA C900, pressure class 235 psi, DR Modify Section Backfilling Trenches as follows: a) Article 2.1 Backfill Materials add paragraph E as follows: If native material obtained from excavations is unsuitable for bedding or pipe zone materials and if trench bottom is unsuitable to support pipe, import granular borrow. b) Article 3.4 Trench above Pipe Zone, paragraph D add the following: For sewer lines, install identification tape two feet above top of pipe. c) Article 3.6 Compaction, paragraph A change subparagraphs 1 and 2, and add 3 through 5 as follows: 1. A-1 soils: Use Modified Proctor Density. 2. Other soils: Use Standard Proctor Density. Richfield City 3 Construction Standards

5 3. 96 percent or greater for bedding and pipe zone materials percent for backfill of trenches in traveled areas percent for backfill of trenched in non-traveled areas. 29. Modify Section Trenchless Utility Installation as follows: a) Add Article 2.4 Casing Spaces with paragraph A as follows: Casing Spacers: Polyethylene, 8 inches minimum length and heights as needed to fit casing. b) Article 3.4 Pipe Support in Casing Tunnel, paragraph A delete and replace with the following: Install casing spacers per manufacturer s recommendations and as follow. Place casing spacers on each side of pipe joint with distance not to exceed 2 feet. Place casing spacers at intervals not to exceed 8 feet. c) Article 3.4 Pipe Support in Casing Tunnel, paragraph B delete and replace with the following: Install cover over end of casing to prevent backfill material from entering casing. 30. Modify Section Commissioning of Water Utilities as follows: a) Article 3.6 Pipe Testing Schedule, paragraph F delete subparagraph Modify Section Water Distribution and Transmission as follows: a) Article 1.3 Performance Requirements, paragraph A delete subparagraphs 1 and 2 and replace with the following: 1. Main Lines: 36 inches minimum and 48 inches maximum. 2. Service lines: 30 inches minimum and 36 inches maximum. b) Article 2.6 Tapping Saddles, paragraph A add the following: Provide nylon coated saddle with full support around pipe circumference and 2 inch minimum bearing width. Do not use u-bolt type strap or type with lugs which dig into pipe. c) Article 2.7 Service Connection, paragraph A add the following: Do not use flared fittings. d) Article 2.7 Service Connection, add paragraph B as follows: Polyethylene pipe; Section with compression fittings in accordance with AWWA C800. e) Article 2.8 Accessories, paragraph A add the following: In areas with high water table, use stainless steel bolts and nuts. f) Article 2.8 Accessories add paragraph H as follows: Tracer Wire: 14 AWG solid, Type UF, copper conductor with PVC insulation, suitable for direct burial and rated for 600 volts. Blue colored insulation to meet color code standard for identification of buried utilities. For splices, use direct bury, waterproof wire connector. g) Article 3.4 Installation Pipe and Fitting, paragraph A delete subparagraph 2. h) Article 3.4 Installation Pipe and Fitting delete paragraph H and replace with the following: Tracer Wire: Install tracer wire continuous below spring line of pipe. Install tracer wire with PVC main lines, PVC fire hydrant lines and polyethylene service lines. Wrap tracer wire around fire hydrant above ground, extend loop to top of valve boxes, and wrap around meter setter. Where there is existing tracer wire, connect new tracer wire Richfield City 4 Construction Standards

6 to existing tracer wire. If splices are required, make watertight connections. i) Article 3.6 Installation Valves and Valve Boxes, paragraph A delete subparagraph 4. j) Article 3.7 Installation Taps delete paragraph E and replace with the following: In areas with high water table, use stainless steel bolts and nuts. k) Article 3.8 Installation Service Lines, paragraph B delete subparagraph 5 and replace with the following: For copper- to- copper connections use brass compression coupling. l) Article 3.9 Installation Water Main Loop (Syphon) delete paragraph D. m) Article 3.10 Backfilling, paragraph A, subparagraph 1 delete reference to brass wedge installations. 32. Modify Section Water Valves as follows: a) Article 2.1 Valves General, paragraph A, subparagraph 2 delete first sentence and replace with the following: Use mechanical joint ends unless indicated otherwise. b) Article 2.1 Valves General add paragraph I as follows: In areas with high water table, provide stainless steel bolts for bolts on valves exposed to soil. 33. Modify Section Hydrants as follows: a) Article 2.1 Dry-Barrel Fire Hydrant, paragraph A add subparagraph 11 as follows: In areas with high water table, provide stainless steel bolts for bolts on hydrants exposed to soil. b) Article 2.2 Pipe and Fittings, paragraph A add the following: In areas with high water table, use stainless steel bolts and nuts. c) Article 3.2 Installation delete paragraph B and replace with the following: Install so bottom of hydrant base flange is 4 to 6 inches above finish grade. d) Article 3.2 Installation delete paragraph F. 34. Modify Section Water Meter as follows: a) Article 2.3 Service Line, Valves, and Fittings, paragraph C add the following: Provide 15 inch height with ball valve inlet and dual check valve outlet. b) Article 2.3 Service Line, Valves, and Fittings - delete paragraph E and replace with the following: Provide bypass for 1.5 and 2 inch meters. 35. Modify Section Disinfection as follows: a) Article 3.2 Disinfection of Water Lines, paragraph D add the following: Take sample from every 1,200 feet of pipe line and every branch. 36. Modify Section Sanitary Sewerage Systems as follows: a) Article 2.3 Manholes delete paragraph B and replace with the following: Steps: Fiberglass or steel encased by copolymer polypropylene, placed at 12 inches on center vertically, set into manhole wall. b) Article 2.3 Manholes delete paragraph C and replace with the following: Tope: Eccentric cone. Eccentric flat slab concrete deck allowed only with ENGINEER S permission. Richfield City 5 Construction Standards

7 c) Article 3.3 Installation Manholes, paragraph D replace 1/2 inch with ¼ inch. 37. Modify Section Storm Drainage Systems as follows: a) Article 2.5 Cleanouts and Manholes delete paragraph B and replace with the following: Steps: Fiberglass or steel encased by copolymer polypropylene, placed at 12 inches on center vertically, set into manhole wall. b) Article 2.5 Cleanouts and Manholes delete paragraph C and replace with the following: Tope: Eccentric cone. Eccentric flat slab concrete deck allowed only with ENGINEER S permission. c) Article 2.6 Inlets and Catch Basins, paragraph B add subparagraph 3 as follows: Provide bicycle safe grate. B. Current (2007) edition of the Manual of Standard Plans published by the Utah Chapter of the American Public Works Association (APWA) with the following modifications: 1. Current amendments published by the Utah Chapter of the APWA. 2. Delete Plan No Refer to supplemental drawing S-131 and S Delete Plan No. 211 and 213. Refer to supplemental drawing S Delete Plan No. 215, 216 and 221. Refer to supplemental drawing S-151 and S Delete Plan No. 255 and 256. Refer to supplemental drawing S-182 and S Delete Plan No. 271, 272, 274, and Delete Plan No. 341, 345, 360, 361, 362 and Modify Plan No. 382 as follows: a) Note 1B; subparagraph 1 change lift thickness to not exceed 6 inches. b) Note 2; - refer to supplemental drawing S-181 for pipe zone width. c) Delete note Modify Plan No. 402 as follows: a) Delete dust pan. b) Note 6; locking devices are not required unless indicated otherwise. 10. Delete Plan No. 411, 412, 413, and Delete Plan No Delete Plan No Refer to supplemental drawing S Delete Plan No Refer to supplemental drawing S Delete Plan No Refer to supplemental drawing S Delete Plan No. 523 and 525. Refer to supplemental drawing S Delete Plan No Refer to supplemental drawing S Delete Plan No. 551 and Delete Plan No. 561 and 562. Refer to supplemental drawing S-421, 422 and Delete Plan No Refer to supplemental drawing S Delete Plan No. 575 and Plan No. 710 through 742; these plans are superseded by and supplemental to Rocky Mountain Power requirements and Richfield City Residential Subdivision Street lighting Standard and Commercial Street Lighting Standard. Richfield City 6 Construction Standards

8 C. Supplemental Specifications (see attachments): 1. Section (S) Progress Schedule D. Supplemental Drawings (see attachments): 1. S-101 Street Section 100 Width 2. S-102 Street Section - 90' Width 3. S-103 Street Section - 80' Width (No On-Street Parking) 4. S-104 Street Section - 80' Width (With On-Street Parking) 5. S-105 Street Section - 66' Width (With On-Street Parking) 6. S-106 Street Section - 66' Width (No On-Street Parking) 7. S-107 Street Section - 60' Width 8. S-108 Street Section - 50' Width 9. S-121 Standard Cul-De-Sac Detail 10. S-122 Temporary Turnaround At End Of Subdivision Phases 11. S-123 Standard Intersection, Utility & Signing Location Detail (w/ No Planter Strip) 12. S-124 Standard Intersection, Utility & Signing Location Detail (w/ Planter Strip) 13. S-131 Type B1 Curb & Gutter Detail 14. S-132 Type B2 Curb & Gutter Detail (Water Bearing) 15. S-133 Curb & Gutter Tapered End Detail 16. S-134 Concrete Cross Gutter Detail 17. S-141 Concrete Sidewalk Against Curb 18. S-142 Concrete Sidewalk With Planter Strip 19. S-151 Drive Depression & Transition Details 20. S-152 Drive Depression & Transition Details 21. S-161 Corner Curb Ramp (W/ Out Planter Strip) 22. S-162 Corner Curb Ramp (W/ Planter Strip) 23. S-163 Perpendicular Curb Ramp Detail (W/ Planter Strip) 24. S-164 Perpendicular Curb Ramp Detail 25. S-165 Parallel Curb Ramp Detail 26. S-166 Detectable Warning Surface & Slope Table 27. S-171 Standard Concrete Joints 28. S-172 Standard Pavement Edge Detail 29. S-173 Standard Expansion Joint Around Objects 30. S-181 Standard Utility Trench Detail 31. S-182 Utility Trench With Flowable Fill (Not Used) 32. S-183 Standard Roadway Repair Detail 33. S-184 Standard Street Sign & Post Detail 34. S-185 Standard Stop Sign & Post Detail 35. S-186 Standard Manhole Concrete Collar Detail 36. S-187 Standard Valve Concrete Collar Detail 37. S-211 Residential Subdivision Street Lighting Standard 38. S-212 Commercial Street Lighting Standard 39. S-301 Standard Sewer Manhole Detail 40. S-302 Standard Sewer Drop Manhole Detail Richfield City 7 Construction Standards

9 41. S-303 Standard Sewer Service Connection Detail 42. S-304 Standard Sewer Cleanout Detail 43. S-311 Standard Utility Line Crossing Detail 44. S-351 Standard Catch Basin Detail 45. S-352 Standard Junction Box Detail 46. S-353 Standard Storm Drain Manhole Detail 47. S-354 Standard Dry Well Detail 48. S-401 Standard Fire Hydrant Detail 49. S-402 Standard Gate Valve Detail 50. S-403 Meter Box Detail (3/4" To 1" Meters) 51. S-404 Meter Box Detail (1 ½ To 2 Meters) 52. S-405 Meter Box Detail (3" To 6" Meters) 53. S-406 Standard Water Service Connection Detail 54. S-421 Standard Thrust Blocks 55. S-422 Standard Thrust Blocks (Con't) 56. S-423 Standard Restrained Joints E. Subdivision Development Agreement The Developer shall execute Richfield City s Subdivision Development Agreement prior to starting work. (See attachment.) F. Guidance for Selection of Construction Materials The following is a list of typical construction materials for public works projects. This list is not comprehensive. Projects may vary in scope, and engineering judgment should be used to select materials for construction. Consult with Richfield City s staff and engineer during project design. 1. Plant-Mix Asphalt Paving: a) Asphalt: For residential traffic areas use PG58-22 and for commercial, industrial or other heavy truck traffic areas use PG b) Aggregate: ½ inch maximum gradation (DM-1/2) or ¾ inch (DM-3/4) for commercial, industrial or heavy truck areas. c) Mix Design: Marshall Method. 2. Culinary Water: a) Main Lines: Ductile Iron or AWWA C900 PVC. b) Service Lines: Copper or high density polyethylene. 3. Sewer: a) Mains and Service Lines: PVC. b) Manholes: Precast concrete at 250 feet spacing. 4. Pipe Culverts: corrugated steel with zinc coating. 5. Storm Drain: a) Pipe: PVC or corrugated polyethylene with smooth interior. b) Inlet and Junction Structures: Cast-in-place or precast concrete. c) Manholes: Precast concrete. Richfield City 8 Construction Standards

10 G. Encroachment Permit: Prior to cutting any paved street, the developer shall obtain an encroachment permit from Richfield City. The street shall be repaired in accordance with Richfield City s Construction Standards. At the completion of the construction work, the street repair shall be inspected and accepted by Richfield City. Unacceptable work shall be corrected by the developer. (See attached Roadway/Right-of-Way Encroachment Permit.) Richfield City 9 Construction Standards

11 SUPPLEMENTAL SPECIFICATIONS

12 SECTION (S) PROGRESS SCHEDULE PART 1 GENERAL 1.1 SECTION INCLUDES A. Requirements for preparing and submitting construction progress schedule. 1.2 TYPE OF SCHEDULE A. CONTRACTOR s choice. 1.3 SUBMITTALS A. Prior to construction, submit preliminary progress schedule. B. During construction submit: 1. Updated progress schedule on monthly basis. 2. Promptly deliver to ENGINEER and OWNER. 1.4 CONTENT OF SCHEDULE A. Title Block: show on each page: 1. Project title and CONTRACTOR s name. 2. Date of submittal, revision number, and page number. 3. Legend of symbols, codes and abbreviations. B. Activities: Show complete sequence of construction activity networks with starting and ending time for all activities, in no less than weekly divisions. Provide complete sequence of construction by activity. PART 2 PRODUCTS Not Used. PART 3 EXECUTION Not Used. END OF SECTION Richfield City (S) Progress Schedule Supplemental Specification ( ) Page 1

13 SUPPLEMENTAL DRAWINGS

14 Richfield City Supplemental Drawings SECTION Roadwork & Miscellaneous S-101 STREET SECTION - 100' WIDTH S-102 STREET SECTION - 90' WIDTH S-103 STREET SECTION - 80' WIDTH (No On-Street Parking) S-104 STREET SECTION - 80' WIDTH (With On-Street Parking) S-105 STREET SECTION - 66' WIDTH (With On-Street Parking) S-106 STREET SECTION - 66' WIDTH (No On-Street Parking) S-107 STREET SECTION - 60' WIDTH S-108 STREET SECTION - 50' WIDTH S-121 STANDARD CUL-DE-SAC DETAIL S-122 TEMPORARY TURNAROUND AT END OF SUBDIVISION PHASES S-123 STANDARD INTERSECTION, UTILITY & SIGNING LOCATION DETAIL (w/ NO PLANTER STRIP) S-124 STANDARD INTERSECTION, UTILITY & SIGNING LOCATION DETAIL (w/ PLANTER STRIP) S-131 TYPE B1 CURB & GUTTER DETAIL S-132 TYPE B2 CURB & GUTTER DETAIL (WATER BEARING) S-133 CURB & GUTTER TAPERED END DETAIL S-134 CONCRETE CROSS GUTTER DETAIL S-141 CONCRETE SIDEWALK AGAINST CURB S-142 CONCRETE SIDEWALK WITH PLANTER STRIP S-151 DRIVE DEPRESSION & TRANSITION DETAILS S-152 DRIVE DEPRESSION & TRANSITION DETAILS S-161 CORNER CURB RAMP (w/ OUT PLANTER STRIP) S-162 CORNER CURB RAMP (w/ PLANTER STRIP) S-163 PERPENDICULAR CURB RAMP DETAIL (w/ PLANTER STRIP) S-164 PERPENDICULAR CURB RAMP DETAIL S-165 PARALLEL CURB RAMP DETAIL S-166 DETECTABLE WARNING SURFACE & SLOPE TABLE S-171 STANDARD CONCRETE JOINTS S-172 STANDARD PAVEMENT EDGE DETAIL S-173 STANDARD EXPANSION JOINT AROUND OBJECTS S-181 STANDARD UTILITY TRENCH DETAIL S-182 N/A S-183 STANDARD ROADWAY REPAIR DETAIL S-184 STANDARD STREET SIGN & POST DETAIL S-185 STANDARD STOP SIGN & POST DETAIL S-186 STANDARD MANHOLE CONCRETE COLLAR DETAIL S-187 STANDARD VALVE CONCRETE COLLAR DETAIL

15 SECTION Street Lighting S-211 RESIDENTIAL SUBDIVISION STREET LIGHTING STANDARD & FEES S-212 COMMERCIAL STREET LIGHTING STANDARD & FEES SECTION 300 Sewer SANITARY S-301 STANDARD SEWER MANHOLE DETAIL S-302 STANDARD SEWER DROP MANHOLE DETAIL S-303 STANDARD SEWER SERVICE CONNECTION DETAIL S-304 STANDARD SEWER CLEANOUT DETAIL S-311 STANDARD UTILITY LINE CROSSING DETAIL STORM S-351 STANDARD CATCH BASIN DETAIL S-352 STANDARD JUNCTION BOX DETAIL S-353 STANDARD STORM DRAIN MANHOLE DETAIL S-354 STANDARD DRY WELL DETAIL SECTION 400 Water CULINARY S-401 STANDARD FIRE HYDRANT DETAIL S-402 STANDARD GATE VALVE DETAIL S-403 METER BOX DETAIL (3/4" TO 1" METERS) S-404 METER BOX DETAIL (1 ½ TO 2 METERS) S-405 METER BOX DETAIL (3" TO 6" METERS) S-406 STANDARD WATER SERVICE CONNECTION DETAIL S-421 STANDARD THRUST BLOCKS S-422 STANDARD THRUST BLOCKS (CON'T) S-423 STANDARD RESTRAINED JOINTS

16 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-101 UPDATE: 3/29/2010 S-101

17 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-102 UPDATE: 4/2/2010 S-102

18 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-103 UPDATE: 3/29/2010 S-103

19 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-104 UPDATE: 3/29/2010 S-104

20 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN PROJECT: TBL: _1stndrd-ir2800.ctb CHECK: T.M.J FILE: S-105 UPDATE: 1/19/2010 S-105

21 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-106 UPDATE: 6/24/2014 S-106

22 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-107 UPDATE: 6/25/2014 S-107

23 ROADWORK & MISCELLANEOUS DRAWN: J.D.B PEN CHECK: T.M.J FILE: S-108 UPDATE: 6/25/2014 S-108

24 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-121 UPDATE: 5/22/2014 S-121

25 ROADWAY & MISCELLANEOUS DRAWN: LG/KC PEN CHECK: T.M.J FILE: S-122 UPDATE: 5/23/2014 S-122

26 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-123 UPDATE: 5/21/2010 S-123

27 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-124 UPDATE: 5/21/2010 S-124

28 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-131 UPDATE: 3/26/2010 S-131

29 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-132 UPDATE: 3/26/2010 S-132

30 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: J.F.S FILE: S-133 UPDATE: 3/26/2010 S-133

31 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-134 UPDATE: 3/26/2010 S-134

32 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-141 UPDATE: 3/26/2010 S-141

33 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-142 UPDATE: 3/26/2010 S-142

34 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN PROJECT: TBL: _1stndrd-ir2800.ctb CHECK: T.M.J FILE: S-151 UPDATE: 3/26/2010 S-151

35 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-152 UPDATE: 3/26/2010 S-152

36 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-161 UPDATE: 3/29/2010 S-161

37 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-162 UPDATE: 5/22/2014 S-162

38 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-163 UPDATE: 4/2/2010 S-163

39 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-164 UPDATE: 4/2/2010 S-164

40 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-165 UPDATE: 3/26/2010 S-165

41 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-166 UPDATE: 3/26/2010 S-166

42 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-171 UPDATE: 5/21/2010 S-171

43 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-172 UPDATE: 3/26/2010 S-172

44 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-173 UPDATE: 3/26/2010 S-173

45 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-181 UPDATE: 10/2/2015 S-181

46 STANDARD DETAIL ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-183 UPDATE: 3/26/2010 S-183

47 ROADWAY & MISCELLANEOUS DRAWN: LG/KC PEN CHECK: T.M.J FILE: S-184 UPDATE: 5/22/2014 S-184

48 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-185 UPDATE: 5/22/2014 S-185

49 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-186 UPDATE: 3/26/2010 S-186

50 ROADWAY & MISCELLANEOUS DRAWN: L.G PEN CHECK: T.M.J FILE: S-187 UPDATE: 3/26/2010 S-187

51

52

53 SEWER - SANITARY DRAWN: L.G PEN CHECK: J.F.S FILE: S-301 UPDATE: 3/26/2010 S-301

54 SEWER - SANITARY DRAWN: L.G PEN CHECK: J.F.S FILE: S-302 UPDATE: 3/26/2010 S-302

55 SEWER - SANITARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-303 UPDATE: 5/22/2014 S-303

56 SEWER - SANITARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-304 UPDATE: 3/26/2010 S-304

57 SEWER - SANITARY DRAWN: L.G PEN CHECK: J.F.S FILE: S-311 UPDATE: 3/26/2010 S-311

58 STORM - SEWER DRAWN: L.G PEN CHECK: T.M.J FILE: S-351 UPDATE: 3/26/2010 S-351

59 SEWER - STORM DRAWN: L.G PEN CHECK: T.M.J FILE: S-352 UPDATE: 3/26/2010 S-352

60 SEWER - STORM DRAWN: L.G PEN CHECK: J.F.S FILE: S-353 UPDATE: 3/26/2010 S-353

61 SEWER - STORM DRAWN: L.G PEN CHECK: J.F.S FILE: S-354 UPDATE: 3/26/2010 S-354

62 WATER - CULINARY DRAWN: L.G PEN CHECK: J.F.S FILE: S-401 UPDATE: 3/26/2010 S-401

63 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-402 UPDATE: 3/26/2010 S-402

64 WATER - CULINARY DRAWN: L.G PEN CHECK: B.R.B FILE: S-403 UPDATE: 3/26/2010 S-403

65 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-404 UPDATE: 3/26/2010 S-404

66 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-405 UPDATE: 3/26/2010 S-405

67 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-406 UPDATE: 3/26/2010 S-406

68 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-421 UPDATE: 3/26/2010 S-421

69 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-422 UPDATE: 3/26/2010 S-422

70 WATER - CULINARY DRAWN: L.G PEN CHECK: T.M.J FILE: S-423 UPDATE: 3/26/2010 S-423

71 SUBDIVISION DEVELOPMENT AGREEMENT

72

73

74

75

76

77

78

79

80

81

82

83 ENCROACHMENT PERMIT

84

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction

YAKIMA COUNTY, WASHINGTON. Special Provisions For Water Main Construction YAKIMA COUNTY, WASHINGTON Special Provisions For Water Main Construction The 2014 Standard Specifications for Road, Bridge, and Municipal Construction as prepared by the Washington State Department of

More information

Chapter 3: Permit Procedures and Requirements

Chapter 3: Permit Procedures and Requirements Chapter 1: General Provisions 1 1 Short Title 1 2 Jurisdiction 1 3 Amendments and Revisions 1 4 Enforcement Responsibility 1 5 Review Process 1 6 Prior Approval 1 7 Relationship to Other Standards 1 8

More information

PART 5 WATER SYSTEMS

PART 5 WATER SYSTEMS PART 5 WATER SYSTEMS Abbreviations and Symbols Plan 501 Abbreviations and symbols for water... 205 Concrete Boxes and Hardware 502 27" Frame and cover... 207 503 38" Frame and cover... 209 505 Concrete

More information

SECTION PUBLIC WATER SERVICE CONNECTIONS

SECTION PUBLIC WATER SERVICE CONNECTIONS SECTION 33 14 14 PUBLIC WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for water service connections to small commercial, light industrial, and residential

More information

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of chilled water piping installed for the University of Missouri. DESIGN GUIDELINES: 1. Materials 1.1. Pipe

More information

DRINKING WATER LINE INSTALLATION STANDARDS

DRINKING WATER LINE INSTALLATION STANDARDS 30" MIN. 72" MAX. ORIGINAL GROUND SURFACE BACKFILL WITH A-1-a OR NATIVE MATERIAL PER APWA STANDARDS. MATERIAL MUST MEET APWA STANDARD FOR GRANULAR BORROW. COMPACT BACKFILL ABOVE PIPE ZONE TO 96% DENSITY

More information

SECTION 401 WATER PIPE AND FITTINGS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS

SECTION 401 WATER PIPE AND FITTINGS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS SECTION 401 PIPE AND FITTINGS PART 2 MATERIALS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS A. PVC Pressure Pipe sizes 4 inch through 12 inch: ANSI/AWWA C 900 1. DR18 B. PVC Pressure Pipe sizes 14 inch

More information

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification

More information

SECTION WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

SECTION WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA SECTION 6900 - WATER MAINS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA 6901 DESIGN CRITERIA A. General 1. The design standards presented in the City of Lee's Summit Design Criteria are the minimum standards

More information

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT]

PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] PART II. - SPECIFICATIONS AND DESIGN STANDARDS TO CITY OF HEWITT, TEXAS SUBDIVISION ORDINANCE FOR PUBLIC WORKS CONSTRUCTION [TEXT] A. - General. B. - Streets. C. - Stormwater drainage system. D. - Water

More information

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES B-1 General Notes: SACWSD Standard Construction Drawing Notes 1. No work shall begin on any water or wastewater construction project until the construction

More information

SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2017

SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2017 SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2017 STANDARD SPECIFICATIONS 102.12 Best Value Contracting Partial payments shall be withheld if contractor is working on site and has not satisfied

More information

SUPPLEMENTAL DRAWINGS

SUPPLEMENTAL DRAWINGS CITY OF GREATER SUDBURY SUPPLEMENTAL DRAWINGS TO THE ONTARIO PROVINCIAL STANDARD DRAWINGS Rev: February 2012 CITY OF GREATER SUDBURY STANDARD DRAWINGS TABLE OF CONTENTS Greater Sudbury Standard Drawings

More information

Town of Huntertown Lima Road * PO Box 95 * Huntertown, IN Phone (260) * * Fax (260)

Town of Huntertown Lima Road * PO Box 95 * Huntertown, IN Phone (260) *   * Fax (260) HUNTERTOWN APPLICATION FOR NEW WATER AND SEWER SERVICES All requests for new water and sewer service shall be made to the Huntertown Utility Service Board for their approval before any connections can

More information

City of Redding Construction Standards Index

City of Redding Construction Standards Index City of Redding Construction Standards Index A. Purpose and Reference Documents... A1 B. Modifications to the Standard Specifications for Public Works Construction (Greenbook)... B1 I. Streets Materials...

More information

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER

PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER COMMUNICATIONS LIGHTING Street Lighting Plan 710 Riser... 287 730 Collar for street light pole... 289 731 Pull box... 291 732 Trench for street light

More information

PUBLIC WORKS DEPARTMENT GENERAL NOTES

PUBLIC WORKS DEPARTMENT GENERAL NOTES PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard

More information

SECTION 2100 WATER MAIN

SECTION 2100 WATER MAIN SECTION 2100 WATER MAIN WATER MAIN PART 1 GENERAL 1.01 Section Summary A. This section includes product and installation requirements for water main pipe, gate valves, hydrants, fittings, and miscellaneous

More information

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS Storm Sewer System: 1. Detention/retention of stormwater runoff shall be provided in accordance with the requirements of the DuPage County Countywide Stormwater

More information

NC State University Design and Construction Guidelines Division 33 Utilities

NC State University Design and Construction Guidelines Division 33 Utilities 1.0 Purpose A. These guidelines provide methods and requirements to ensure that the connections, attachments, extensions, or other site utility modifications meet NC State standards. B. NC State is responsible

More information

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction. General: 1. Construct utilities in accordance to TWA approved plans and shop drawings. Any deviation from the approved plans shall be approved by the DEVELOPER S ENGINEER and TWA 2. A preconstruction meeting

More information

MATERIAL AND INSTALLATION SPECIFICATIONS FOR CONSTRUCTING WATER SERVICES INSPECTIONS

MATERIAL AND INSTALLATION SPECIFICATIONS FOR CONSTRUCTING WATER SERVICES INSPECTIONS MATERIAL AND INSTALLATION SPECIFICATIONS FOR CONSTRUCTING WATER SERVICES INSPECTIONS A. It is YOUR responsibility to schedule ALL inspections and the installation of water meters with LWD (978) 540-2222,

More information

Amendments to the January 2016 Design Criteria Manual & Supplementary Master Municipal Construction Documents

Amendments to the January 2016 Design Criteria Manual & Supplementary Master Municipal Construction Documents General Figure 2.3.1 16 Revise Revised Figure 2.3.1: New Development Areas where Secondary Suites Apply to include two new areas (#4 and 5). Water 3.3.2 Watermains 31 Add Added wording in Section 3.3.2.3

More information

PIPE AND FITTINGS. Submit product information sheet for joint restraint system to be used.

PIPE AND FITTINGS. Submit product information sheet for joint restraint system to be used. PIPE AND FITTINGS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe B. Fittings C. Special Fittings D. Pipeline Accessories 1.02 DESCRIPTION OF WORK Construct water mains and building service pipes. 1.03

More information

TABLE OF CONTENTS. Chapter 3 - WATER MAIN, VALVES, HYDRANTS AND APPURTENANCES. Chapter 4 - SANITARY SEWER. Chapter 5 - STORM SEWER

TABLE OF CONTENTS. Chapter 3 - WATER MAIN, VALVES, HYDRANTS AND APPURTENANCES. Chapter 4 - SANITARY SEWER. Chapter 5 - STORM SEWER Chapter 3 - WATER MAIN, VALVES, HYDRANTS AND APPURTENANCES Chapter 4 - SANITARY SEWER Chapter 5 - STORM SEWER Chapter 6 - EXCAVATION, TRENCING, BACKFILLING, AND BEDDING Chapter 11 - CONCRETE CURBS, CURB

More information

CULINARY WATER SYSTEMS

CULINARY WATER SYSTEMS CULINARY WATER SYSTEMS I. Water system size determination A. The minimum water line size is 8 inch for distribution lines in a residential subdivision. 1. Subdivisions that have a school or church will

More information

Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION

Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION GENERAL ITEMS SUBGRADE Prior to pouring concrete all subgrades must be wetted and compacted. All formwork

More information

HAIGHTS CREEK IRRIGATION COMPANY

HAIGHTS CREEK IRRIGATION COMPANY HAIGHTS CREEK IRRIGATION COMPANY DEVELOPMENT STANDARDS AND SPECIFICATIONS Adopted by the Haights Creek Irrigation Company Board June 11, 2015 (rev. 4/12/17) Haight s Creek Irrigation Company Adopted June

More information

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork. PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

SECTION CS-2. TRENCH EXCAVATION CONSTRUCTION STANDARDS

SECTION CS-2. TRENCH EXCAVATION CONSTRUCTION STANDARDS SECTION CS-2. TRENCH EXCAVATION CONSTRUCTION STANDARDS CS-2-01. GENERAL: Trench excavation shall conform with the City Standard Specifications. In general a trench is defined as an excavation in which

More information

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION 33 11 13.24 POLYETHYLENE PRESSURE PIPE PART 1 GENERAL... 2 1.1 Description... 2 1.2 Reference Specification... 2 1.3

More information

PERMANENT PAVEMENT REPAIR NO SCALE

PERMANENT PAVEMENT REPAIR NO SCALE SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2011 ADOPTED?????

SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2011 ADOPTED????? SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2011 ADOPTED????? 102.10 Minimum Rate of Wage Scale Typo. Several paragraphs were repeated. 105.5 Inspection of Work Clarified that the contractor

More information

SERVICE LINES, METERS AND APPURTENANCES

SERVICE LINES, METERS AND APPURTENANCES AUGUST02 SECTION 02646 SERVICE LINES, METERS AND APPURTENANCES PART 1 - GENERAL 1.1 DESCRIPTION A. This section concerns materials and installation of corporation stops, curb stops, service lines, meters,

More information

CHAPTER 8 WATER SUPPLY SYSTEM

CHAPTER 8 WATER SUPPLY SYSTEM CHAPTER 8 WATER SUPPLY SYSTEM 8-1 INTRODUCTION These improvement standards shall govern the engineering design of all domestic water systems intended for operation and maintenance by the County of Sutter

More information

All service lines shall conform to the following requirements:

All service lines shall conform to the following requirements: 505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the

More information

SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS

SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS PREFACE AND CITY ENGINEER S LETTER INDEX OF STANDARD DRAWINGS DIVISION 100 GENERAL CONDITIONS ARTICLE 1 DEFINITIONS AND TERMINOLOGY 1.01 Defined Terms ARTICLE 2 PRELIMINARY MATTERS 2.01 Delivery of Bonds

More information

Addendum No. 1 GORDON WATER MAIN REPLACEMENT PWP Bid No.: WA TMWA Capital Project No.: October 3, 2018

Addendum No. 1 GORDON WATER MAIN REPLACEMENT PWP Bid No.: WA TMWA Capital Project No.: October 3, 2018 Addendum No. 1 GORDON WATER MAIN REPLACEMENT PWP Bid No.: WA-2019-004 TMWA Capital Project No.: 10-0001.053 October 3, 2018 The following information, clarifications, changes and modifications are by reference

More information

Public Water Supply District #2 of St. Charles County, Missouri

Public Water Supply District #2 of St. Charles County, Missouri Public Water Supply District #2 of St. Charles County, Missouri POLICIES, PROCEDURES, AND REQUIREMENTS FOR CONNECTION AND INSPECTIONS OF: RESIDENTIAL WATER AND/OR SEWER SERVICE CONNECTIONS COMMERCIAL WATER

More information

SECTION WATER SERVICE PIPING

SECTION WATER SERVICE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS: SECTION 33 1000 WATER SERVICE PIPING A. Drawings and general provisions of Contract, including General and Supplementary Conditions and other Division 1 Specification

More information

ELEVATION (A - A) PLAN GATE W ELL JOB NO. SHEET NO. DATE MARCH 2015 OF. Gate Wel Dimensions - Inches

ELEVATION (A - A) PLAN GATE W ELL JOB NO. SHEET NO. DATE MARCH 2015 OF. Gate Wel Dimensions - Inches CL Gate Wel Opening East Jordan Iron Works, Inc. Manhole Cover No. 1040 (or approved equal) w/ bolted frame 01-APR-2015 15:29 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\wm_det01_8x11_wm01.dgn

More information

SECTION UNIT PRICES. A. This Section specifies administrative and procedural requirements for the unit prices.

SECTION UNIT PRICES. A. This Section specifies administrative and procedural requirements for the unit prices. SECTION 01220 UNIT PRICES PART 1 GENERAL 1.01 SUMMARY A. This Section specifies administrative and procedural requirements for the unit prices. B. The omission of any unit price description from this Section

More information

SECTION MINOR CONCRETE

SECTION MINOR CONCRETE SECTION 03300 - MINOR CONCRETE CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And Payment...

More information

City of Middletown WATER & SEWER DEPARTMENT 82 Berlin Street Middletown, CT TEL: (860) FAX: (860)

City of Middletown WATER & SEWER DEPARTMENT 82 Berlin Street Middletown, CT TEL: (860) FAX: (860) City of Middletown WATER & SEWER DEPARTMENT 82 Berlin Street Middletown, CT 06457 TEL: (860) 638-3500 FAX: (860) 343-8091 GENERAL REQUIREMENTS WATER MAIN AND SERVICE INSTALLATION JANUARY 2017 WATER MAINS:

More information

Summary of the 2011 Changes

Summary of the 2011 Changes The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.

More information

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 02530 - SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

SECTION STORM DRAINAGE

SECTION STORM DRAINAGE SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation

More information

SECTION 1 GENERAL NOTES

SECTION 1 GENERAL NOTES ISSUE DATE NOVEMBER 1st, 2011 SECTION 1 Page List Page Number Page Title COVER COVER GN-01 PAGE 1 GN-02 PAGE 2 GN-03 PAGE 3 GN-04 PAGE 4 GN-05 PAGE 5 GN-06 PAGE 6 GN-07 PAGE 7 : 1. (CCU) STANDARD SPECIFICATIONS

More information

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ONE PIPE LENGTH MAX (REFER TO 1/4/FT SLOPE (MIN) 5'-0 (MIN) OR 4 LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4x6 REFER TO TYPICAL EXCAVATION, VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE

More information

SECTION WATER SERVICE CONNECTIONS

SECTION WATER SERVICE CONNECTIONS SECTION 33 12 13 WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for domestic water service connections to buildings. 2. Corporation stop assembly. 3. Curb

More information

CITY OF GRANBURY STANDARD SPECIFICATIONS For Public Works Projects

CITY OF GRANBURY STANDARD SPECIFICATIONS For Public Works Projects Updated 11/20/2015 CITY OF GRANBURY STANDARD SPECIFICATIONS For Public Works Projects 10/29/2018 JWooldridge TABLE OF CONTENTS STANDARD CONSTRUCTION SPECIFICATIONS FOR PUBLIC WORKS PROJECTS A. WATER DISTRIBUTION

More information

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details Changes for the 2017 TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details The following changes are made to the existing standards and details to clarify or improve existing information.

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 824 SERVICE SUPPLY LINES (WATER)

San Antonio Water System Standard Specifications for Construction ITEM NO. 824 SERVICE SUPPLY LINES (WATER) San Antonio Water System Standard Specifications for Construction ITEM NO. 824 SERVICE SUPPLY LINES (WATER) 824.1 DESCRIPTION: This item shall consist of water service supply lines adjustment and installation

More information

East Wenatchee Water District Supplemental Provisions to the 2012 WSDOT/APWA Standard Specifications

East Wenatchee Water District Supplemental Provisions to the 2012 WSDOT/APWA Standard Specifications East Wenatchee Water District Supplemental Provisions to the 2012 WSDOT/APWA Standard Specifications 1-01 DEFINITIONS and TERMS 1-01.3 Definitions This section is supplemented with the following Deleted

More information

120 WATER DISTRIBUTION SYSTEMS

120 WATER DISTRIBUTION SYSTEMS 120 WATER DISTRIBUTION SYSTEMS 120.01 GENERAL 120.01.01 All public water main extensions shall by designed by a Design Professional and shall be approved by the Public Water Supply Section of NCDEQ/DEH.

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it. Section 3 F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it. 3.8 Highway Crossings The design engineer shall, prior to the design of any highway

More information

CURRENT NORTH LAS VEGAS ADDENDA

CURRENT NORTH LAS VEGAS ADDENDA SECTION 1 Section 1.01.73 Fire Service Meter ADD: Type I is not approved for installation in the City of North Las Vegas service area. Section 1.01.107 Pressure Reducing Valve (PRV) or Pressure Regulator

More information

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS COMPLETE THROUGH REVISION #18 April 2009 CITY STANDARD DETAILS REVISIONS Revision No. Revision Date Effective Date 2 August

More information

SECTION WATER UTILITIES

SECTION WATER UTILITIES SECTION 33 10 00 PART 1 - GENERAL 1.1 DESCRIPTION: Underground water distribution system complete, ready for operation, including all appurtenant structures, and connections to both new building service

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1 DIVISION 3: SEWER 3.1 DESIGN CRITERIA A. APPLICABILITY 1. These Design Standards shall govern all construction and upgrading of public sanitary sewer facilities in the City of Dundee and applicable work

More information

CITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS

CITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS SEWER AND WATER SERVICE CONNECTIONS PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of the furnishing of all labor, material,

More information

T a b l e o f C o n t e n t s

T a b l e o f C o n t e n t s C i t y o f G l a d s t o n e P u b l i c W o r k s D e s i g n S t a n d a r d s T a b l e o f C o n t e n t s SECTION THREE SANITARY SEWER REQUIREMENTS... 1 3.0000 SANITARY SEWERS... 1 3.0010 General

More information

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger 1.0 GENERAL 1.1 Scope 1.1.1 The work covered by this section involves the installation of water and sewer service connections and all other associated work. 1.2 Authorization 1.2.1 Do not install service

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 331213 - WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for domestic water service connections to buildings. 2. Corporation stop assembly. 3. Curb

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES PART 1 GENERAL 1.01 SUMMARY This Section includes: Section 02081 CAST-IN-PLACE A. Cast-in-place concrete manholes for sanitary sewers and storm sewers, including box sewers. B. Pile-supported concrete

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS SECTION 00005B TABLE OF CONTENTS ***CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS***

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS SECTION 00005B TABLE OF CONTENTS ***CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS*** 00005B *** *** BOLD ITALICIZED Item is bound within this specification manual. Regular non-italicized Item is not bound within this specification manual, however item is part of the contract. Contents

More information

CALAVERAS COUNTY WATER DISTRICT Ebbetts Pass Water System Reach 3A Pipeline Replacement Project CCWD CIP No ADDENDUM 2

CALAVERAS COUNTY WATER DISTRICT Ebbetts Pass Water System Reach 3A Pipeline Replacement Project CCWD CIP No ADDENDUM 2 CALAVERAS COUNTY WATER DISTRICT Ebbetts Pass Water System Reach 3A Pipeline Replacement Project CCWD CIP No. 11078 ADDENDUM 2 Date Issued: December 2, 2015 **** Receipt of addenda must be acknowledged

More information

SECTION MEASUREMENT AND PAYMENT

SECTION MEASUREMENT AND PAYMENT SECTION 01026 PART 1 GENERAL 1.1 SECTION INCLUDES A. Explanation and Definitions B. Measurement C. Payment D. Schedule of Values E. Application for Payment 1.2 EXPLANATION AND DEFINITIONS A. The following

More information

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION UTILITY MANHOLES AND STRUCTURES SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition

More information

SECTION WATER DISTRIBUTION SYSTEM

SECTION WATER DISTRIBUTION SYSTEM Conditions of Use/ Responsibility of Data Montgomery County Public Schools Facilities Guide DIVISION 2 - SITE WORK These guideline specifications are to be used by the A/E as a base document in the development

More information

Failure to acknowledge all addenda in the BID may cause rejection of the BID. See Instructions to Bidders.

Failure to acknowledge all addenda in the BID may cause rejection of the BID. See Instructions to Bidders. Addendum #1 Project: Coteau Street & Utility Improvements Bid Date: 1:00 P.M., Local Time, March 20, 2017 Bid Location: Office of the City Administrator/Clerk, City of Lake Benton 106 S. Center Street

More information

ITEM NO. 824 SERVICE SUPPLY LINES (WATER)

ITEM NO. 824 SERVICE SUPPLY LINES (WATER) ITEM NO. 824 SERVICE SUPPLY LINES (WATER) 824.1 DESCRIPTION: This item shall consist of water service supply lines installation and adjustment installed in accordance with these specifications and as directed

More information

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1 Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2

More information

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete

More information

Section 403. DRAINAGE STRUCTURES

Section 403. DRAINAGE STRUCTURES 403.01 Section 403. DRAINAGE STRUCTURES 403.01. Description. This work consists of adjusting, constructing, or temporarily lowering drainage structures and cleaning existing drainage structures and leads

More information

1. Will have water lines designed by a North Carolina Registered Professional Engineer.

1. Will have water lines designed by a North Carolina Registered Professional Engineer. 03/07/16 DEVELOPER/OWNER RESPONSIBILITES 1. Will have water lines designed by a North Carolina Registered Professional Engineer. 2. Will have the water line installed by a North Carolina Licensed Utility

More information

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No. (SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No. Special Provision No. 407S06 July 2010 Aggregate Requirements, Lift Rings,

More information

STREET IMPROVEMENTS (Refer to Title 18, chapter entitled "STREETS" of the Layton Municipal Code.)

STREET IMPROVEMENTS (Refer to Title 18, chapter entitled STREETS of the Layton Municipal Code.) STREET IMPROVEMENTS (Refer to Title 18, chapter 18.24 entitled "STREETS" of the Layton Municipal Code.) I. Street widths STREET TYPE (ALL MEASUREMENTS IN FEET) ROW WIDTH LAYTON CITY STANDARD STREET SECTIONS

More information

MEASUREMENT & PAYMENT (CITY FUNDED PROJECTS)

MEASUREMENT & PAYMENT (CITY FUNDED PROJECTS) 00950 - Measurement & Payment Page 00950-1 00950 - MEASUREMENT & PAYMENT (CITY FUNDED PROJECTS) (Last revised 5/20/10) SELECTED LINKS TO SECTIONS WITHIN THIS SPECIFICATION Base Course & Paving Curb & Gutter,

More information

SECTION STORM DRAIN

SECTION STORM DRAIN PART 1 - GENERAL 1-01 SECTION INCLUDED A. Furnishing and installing storm drainage facilities, including pipe, cleanout, manhole structures and inlet structures. 1-02 RELATED SECTIONS A. Division 00 Contract

More information

ITEM 430 CONSTRUCTION OF UNDERGROUND UTILITIES

ITEM 430 CONSTRUCTION OF UNDERGROUND UTILITIES AFTER MARCH 1, 2012 ITEM 430 CONSTRUCTION OF UNDERGROUND UTILITIES 430.1 Description. This item shall govern for all excavation required for the construction of sewers, sewer structures, pipe culverts,

More information

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

B. Fiberglass for construction in back lot easements placed on cast-in-place base. Section 02083 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Fiberglass manholes for unpaved areas placed on top of a precast base to form a manhole. B. Fiberglass for construction in back lot easements

More information

SECTION NATURAL GAS DISTRIBUTION

SECTION NATURAL GAS DISTRIBUTION SECTION 33 51 00 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS REFER TO PAVEMENT PATCHING DETAIL FOR REQUIREMENTS ABOVE FINISHED SUBGRADE EL. MAXIMUM ALLOWABLE WIDTH OF PAVEMENT PATCH, SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS MAXIMUM TRENCH WIDTH AS REQUIRED

More information

CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA

CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA CHAPTER 3 WATER SYSTEM DESIGN 3.1 WATER SYSTEM DESIGN GENERAL 3.1.1 Criteria for the design of water service and water distribution lines

More information

SECTION FACILITY SANITARY SEWERS

SECTION FACILITY SANITARY SEWERS SECTION 22 13 13 FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 03 48 10 PRECAST CONCRETE MANHOLES PART 1: GENERAL 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers and water lines or as indicated on the Drawings. B. Precast concrete sanitary

More information

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.

More information

DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION. Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe

DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION. Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe Revised: October 25, 2007 Revised: June 11, 2010 DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe Delete Section 550

More information

CITY OF FARGO SPECIFICATIONS REMOVALS

CITY OF FARGO SPECIFICATIONS REMOVALS REMOVALS PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of all labor, material, and equipment necessary to perform vegetation

More information

PART 1 COMMON FOR WATER & WASTEWATER CONSTRUCTION TITLE By Other Than Open Cut (Non-T.x.D.O.T. - Non Railroad) --- 101 Highway Crossing - All Wastewater Mains & Water Mains 12" and Smaller in Diameter.

More information

SECTION FIRE HYDRANTS

SECTION FIRE HYDRANTS SECTION 21 11 10 PART 1. GENERAL 1.1 SUMMARY: A. Work consists of furnishing and installing new fire hydrants, (boot with ductile iron retainer gland, standpipe and hydrant complete) plus constructing

More information

APWA 2007 LOGAN CITY AMENDMENTS STANDARDS AND SPECIFICATIONS REVISION 12 MARCH Page 1 of 72

APWA 2007 LOGAN CITY AMENDMENTS STANDARDS AND SPECIFICATIONS REVISION 12 MARCH Page 1 of 72 APWA 2007 STANDARDS AND SPECIFICATIONS LOGAN CITY AMENDMENTS REVISION 12 MARCH 2008 Page 1 of 72 SECTION 01 43 00 QUALITY ASSURANCE PART 1 GENERAL 1.3 INSTALLER B. Certificates: When required or request

More information

CITY OF FARGO SPECIFICATIONS REMOVALS

CITY OF FARGO SPECIFICATIONS REMOVALS REMOVALS PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of all labor, material, and equipment necessary to perform vegetation

More information

SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE SECTION 02622 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE PART 1 - GENERAL 1.1 SCOPE A. The work covered by this section includes furnishing all labor, equipment, and materials required to install and test

More information

CHINO VALLEY FIRE DISTRICT FIRE PROTECTION STANDARD

CHINO VALLEY FIRE DISTRICT FIRE PROTECTION STANDARD CHINO VALLEY FIRE DISTRICT FIRE PROTECTION STANDARD SPECIFICATIONS Establishing Minimum Standards for as Related To Fire Protection STANDARD # 103 REVISED 04/01/19 PAGES 7 SCOPE: These specifications shall

More information