Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Size: px
Start display at page:

Download "Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector"

Transcription

1 mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40) Main Runner with location notches Structural Tee with coped ends mm Mains and Structural Tees Field-Cut Perimeter Connector mm Field Connector for simple installation Floating Perimeter detail Field Connector Perimeter & XL Connector Pre-ed connections for cable trays, utilities and other accessories Rev - 05//7 GRID SPECIFICATIONS Pre-engineered and factory produced aluminium structural ceiling grid with continuously ed slot Grid consists of Main Runners with notches for precise location and connection of coped Structural Tees using simple four screw connectors Capable of supporting power modules, light fixtures, cable trays, partitions, and other accessories Load performance based on building connection spacing of 200mm on center Max grid point load at midspan of.7 kn Max grid uniform load of 2.4 kn/m 2 Safety factor of 2 for all connections System Mass 600mm x 600mm Grid: 40 N/m 2 600mm x 200mm Grid: 30 N/m 2 Grid member center to center spacing can be selected to accommodate project specific specs. (see page 3 for more information) CONNECTOR SPECIFICATIONS High Strength Cast Aluminium Construction Corrosion Resistant Aluminium Casting Ribs on connector to engage with grid and prevent racking Attaches to grid members with (4) screws M0-.5 Turnbuckles with starter rod s into connectors on a 200x200mm spacing On site modifiable connectors for perimeter installation COMPONENTS 3600mm Main Runner / 3600mm Perimeter Angle 600mm Structural Tee / 200mm Structural Tee Field Connector / XL Connector Perimeter Connector x - 4 Screws w/ 4 Lock washer M0-.5 x 78mm Turnbuckle Assembly with Starter Rod Ceiling Hold Down Clips (optional) Factory Applied Gasket (optional) Ceiling Tiles & Lights (supplied by others) Threaded Rod Connection to Building (supplied by others) GRID OPTIONS Grid Color White Paint Black Paint Clear Anodized Grid Thread Pattern Bottom Slot M Hidden Slot Grid Spacing On center (see page 3 for detail) 600 x600mm 600 x 200mm 60 x 60mm 60 x x 63mm 63 x 23mm Other 206 of 9

2 PROFILE OPTIONS M0 Bottom Slot* Bottom Slot* Continuous ed /4-20 top slot Continuous ed M0-.5 bottom slot Continuous ed /4-20 top slot Continuous ed 3 /8-6 bottom slot M0-.5 RH RH Slot* Hidden Slot* Continuous ed /4-20 slots on top and bottom Continuous ed /4-20 slots on top and bottom Bottom /4-20 slot is hidden, can be exposed by drilling through bottom wall cover Light Structural Extrusion* Perimeter* Continuous ed /4-20 top slot For infill applications where complete mounting flexibility across the ceiling is not required Continuous ed /4-20 top slot Intended for fixed perimeter installation areas (See page 6) Utilizes all standard hardware 30 *Note: All Dimensions are in Millimeters 750 Montevideo Road Tel (40) Rev - 05// of 9

3 GRID SPACING AND TILE SIZING Center-on-Center Grid Spacing Inside Grid Dimension Tile size If you want the Grid Spacing to be on a 600 x 600mm or 600 x 200mm module size, use this table to determine tile size requirement: Grid Profile Grid Spacing (L x W) Tile Size (L x W) Bottom Slot & ¼ -20 Hidden Slot M0-.5 & Bottom Slot 600 x 600mm 582 x 582mm +/- 4mm 600 x 200mm 582 x 82mm +/- 4mm 600 x 600mm 580 x 580mm +/- 3mm 600 x 200mm 580 x 80mm +/- 3mm (see example below) Note: Maximum Tile Size = Inside Grid Dimension minus mm. Minimum Tile Size is based on a minimum overlap on the extrusion flange of mm when the tile is shifted all the way to one side. If you want the Grid Spacing to be on a larger module size to fit standard 600 x 600mm or 600 x 200mm nominal tile sizes, use this table: Grid Profile Grid Spacing (L x W) Tile Size (L x W) Bottom Slot & ¼ -20 Hidden Slot M0-.5 & Bottom Slot 60 x 60mm 593 x 593mm +/- 4mm 60 x 20mm 593 x 93mm +/- 4mm 63 x 63mm 593 x 593mm +/- 4mm 63 x 23mm 593 x 93mm +/- 4mm (see example below) Note: Maximum Tile Size = Inside Grid Dimension minus mm. Minimum Tile Size is based on a minimum overlap on the extrusion flange of mm when the tile is shifted all the way to one side. Sizing Based on 600 x 200mm Grid Spacing Sizing Based on 600 x 200mm Nominal Tile Size 580mm 593mm 80mm 93mm 200mm 23mm 600mm 63mm 750 Montevideo Road Tel (40) Rev - 05// of 9

4 PERFORMANCE CRITERIA The bottom side of the structural grid is available with an M0-.5, 3 8-6, or continuous ed slot for mounting items directly to the grid. Refer to the table below for load performance details on the grid and connections. Structural Tee Deflection (Midspan Beam) 600mm 200mm Load Deflection (mm) Ultimate Load = 3. kn Yield Point =.7 kn Calculate midspan beam deflection at any point below yield S = Wl 3 48EI S = Deflection W = load l = 200mm E = 68.9 kn/mm 2 I = 63700mm 4 Load (kn) System Performance Criteria Hanging Method Grid Load Performance (with building connections 200mm x 200mm on centers) Connection to Bottom Slot Connector to Grid Point Load (kn).7 kn*.7 kn* 3.6 kn* Uniform Load (kn/m 2 ) 2.4 kn/m Ultimate Point Load (kn) 3. kn 3.4 kn 7.2 kn *Max point load no less than 200mm apart in any direction. 750 Montevideo Road Tel (40) Rev - 05// of 9

5 FIELD CONNECTOR ASSEMBLY Structural Tee coped for simplified installation and stronger connections Main Runners notched to positively position connectors on center every time Ribs on connector to align with grid and prevent racking XL CONNECTOR Main Runner Notch XL Connector is designed for additional support at the ends of each Main Runner. 750 Montevideo Road Tel (40) Rev - 05// of 9

6 PERIMETER CONNECTOR Bottom of Perimeter Connector is designed with ribs that locate the connector on Perimeter Extrusion. Perimeter Connector can be cut on site to be used in various locations to connect grid together. MAIN RUNNERS AND STRUCTURAL TEES All 600mm and 200mm Structural Tees have coped ends which allows the grid to rest on the longer sections for stronger connections and simplified installation. All 200mm Structural Tees and Main Runners are notched every 600mm on center for proper alignment and spacing of the connectors. 3600mm Note: Structural Tee and Main Runner dimensions are nominal and are adjusted for custom-sized ceiling grid designs 750 Montevideo Road Tel (40) Rev - 05// of 9

7 PERIMETER ANGLES XL Connector (Field-Cut) for Floating Installation Perimeter Connector Main Runner Wall Angle (By Others) Perimeter Angle Floating Installation Detail Fixed Installation Detail Main Runners are utilized when installing with a floating detail. When installing with a floating perimeter, XL Connectors can be utilized to take advantage of the notches and ribs that align extrusions and prevent racking. Additionally it is recommended to utilize a Wall Angle attached to the perimeter. Perimeter Extrusions are designed to create a clean corner joint assembly. Perimeter Angles can be cut on site to desired length when assembled along perimeter walls. Perimeter Angles can also be bolted directly to the wall with appropriate fasteners for wall type. Note, pre-drilling is recommended and through holes are suggested for simpler light fixture or drop ceiling tile installation. 750 Montevideo Road Tel (40) Rev - 05// of 9

8 600 X 600mm CEILING GRID WITH 200 X 200mm TURNBUCKLE LAYOUT AND FIXED PERIMETER mm Main Runner 3600mm 2 3 Field Connectors 4 XL Connector Perimeter Angle 200mm 5 Structural Tee 600mm 6 7 Perimeter Connectors 8 Turnbuckle Assembly Structural Tee 750 Montevideo Road Tel (40) Rev - 05// of 9

9 TURNBUCKLE ASSEMBLY Internally Threaded Anchor (Supplied by others) RH M0-.5 Threaded Rod and connection to decking (Supplied by others) M0-.5 LH/RH x 78mm Turnbuckle M0-.5 Threaded Starter Rod into Turnbuckle M0-.5 RH Threaded Connection to Field Connector 750 Montevideo Road Tel (40) Rev - 05// of 9

Tate Grid. Aluminium Structural Grid System for Data Centres. Metric Edition

Tate Grid. Aluminium Structural Grid System for Data Centres. Metric Edition Tate Grid Aluminium Structural Grid System for Data Centres Metric Edition Tate Grid Aluminium Structural Grid System for Data Centres Tate Grid is the ideal solution for any application where large heavy

More information

Structural Ceiling Grid. Continuous Threaded Slot for Maximum Flexibility

Structural Ceiling Grid. Continuous Threaded Slot for Maximum Flexibility Structural Ceiling Grid Continuous Threaded Slot for Maximum Flexibility 2 Tate s Structural Ceiling Grid Tate s Structural Ceiling Grid is the ideal solution for any application where large heavy items

More information

Tate Strut. Steel Structural Ceiling Grid System for Data Centres. Metric Edition

Tate Strut. Steel Structural Ceiling Grid System for Data Centres. Metric Edition Tate Strut Steel Structural Ceiling Grid System for Data Centres Metric Edition Tate Strut Steel Structural Ceiling Grid System for Data Centres Tate Strut is the ideal solution for any application where

More information

GORDON-INC.COM FAX GASKETED GRIDS. CANTRELL DRUG Little Rock, AR

GORDON-INC.COM FAX GASKETED GRIDS. CANTRELL DRUG Little Rock, AR GASKETED GRIDS CANTRELL DRUG Little Rock, AR CG SYSTEM Applications for CG systems include food service, food processing, pharmaceutical, and hospital industries. Designed with a 1-1/2" face tee to support

More information

PORTA-FAB Cleanroom Ceiling Systems

PORTA-FAB Cleanroom Ceiling Systems PORTA-FAB Cleanroom Ceiling Systems FABLINE 2 GASKET SEAL GRID INSTALLATION INSTRUCTIONS IMPORTANT Porta-Fab Advises A Thorough Reading of These Instructions Before Beginning Installation. INTRODUCTION

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

HOLD DOWN CLIPS #WGACHD LIFT & SHIFT CLIPS #WGACLNS [19.05] 3/4" 1/4" [6.35]TYP. REVEAL HOLD DOWN CLIP (BY OTHERS) FASTENERS LIFT & SHIFT

HOLD DOWN CLIPS #WGACHD LIFT & SHIFT CLIPS #WGACLNS [19.05] 3/4 1/4 [6.35]TYP. REVEAL HOLD DOWN CLIP (BY OTHERS) FASTENERS LIFT & SHIFT SAFETY CLIPS 5/6" H.D. T-GRID #8x5/8" OR PANHEAD SCREWS SAFETY CLIP 3" = '-0" [6.35] TYP. REVEAL LIFT & SHIFT SYSTEM SECTION [9.05] [6.35]TYP. REVEAL SAFETY CLIP 6" = '-0" HOLD DOWN CLIP LIFT & SHIFT CLIP

More information

CEILING & WALL SYSTEMS

CEILING & WALL SYSTEMS CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.

More information

PRELUDE. 24 MAX TM Suspension System Data Centre Ceiling Solutions. Assembly and Installation Instructions

PRELUDE. 24 MAX TM Suspension System Data Centre Ceiling Solutions. Assembly and Installation Instructions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: 4. x 3 mm or longer Self Drilling Screw Phillips Pan Head for attaching structural wall angle, lateral support bar 400 mm

More information

Adjustable Suspension Hanger Technical Datasheet

Adjustable Suspension Hanger Technical Datasheet Adjustable Suspension Hanger sheet The Adjustable Suspension Hangers Clip are a component of the Keylock Ceiling System. The upper vertical side of the hanger allows the Suspension Rod that goes through

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description Ceiling Systems Between us, ideas become reality METALWorkS General Installation Instructions RH200 Custom Hook-on Panels 1.0 GENERAL 1.1. Product Description RH200 system is a downward accessible, metal

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

DETAIL INSTRUCTION No. 1

DETAIL INSTRUCTION No. 1 BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies

More information

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E System description ROCKFON SYSTEM T24 A/E Versatile ceiling system Quick and easy to install Visible grid Easy integration with services and fittings Ceiling comprising Chicago Metallic T24 Click 2890

More information

STANDARD PRODUCTS - CUSTOM LOOK

STANDARD PRODUCTS - CUSTOM LOOK AXIOM ClOUDS STANDARD PRODUCTS - CUSTOM LOOK AXIOM AXIOM can give your next space a unique and crisp feel. The AXIOM family offers dramatic visuals with a variety of flat vertical trims and design profiles.

More information

AXIOM Indirect Field Light Coves

AXIOM Indirect Field Light Coves AXIOM Indirect Field Light Coves Assembly and Installation Instructions 1. GENERAL 1.1 Description The Axiom Indirect Field Light Cove system is a pre-engineered lighting solution designed to be used at

More information

HDCR Series HEAVY DUTY WELDED CEILING SYSTEMS

HDCR Series HEAVY DUTY WELDED CEILING SYSTEMS HEAVY DUTY WELDED CEILING SYSTEMS was developed to provide the market with a heavy duty suspension ceiling system to support diffusers, fill-in panels, and light fixtures in a variety of critical environments.

More information

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E System description ROCKFON SYSTEM T24 A/E Versatile ceiling system Quick and easy to install Visible grid Easy integration with services and fittings Ceiling comprising Chicago Metallic T24 Click 2890

More information

CERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD

CERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD CERTIFICATE OF APPROVAL No CF 429 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of The Sterling Centre,

More information

METALWORKS RH215 Faceted Custom Hook-on Panels

METALWORKS RH215 Faceted Custom Hook-on Panels METALWORKS RH215 Faceted Custom Hook-on Panels Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks RH215 Faceted Custom Hook-on panel system is a downward accessible, custom

More information

ROCKFON SYSTEM T24 X

ROCKFON SYSTEM T24 X System description ROCKFON SYSTEM T24 X Concealed ceiling system Continuous expression GRP SYSTE E asy integration of services X EDGE WAR YEARS IT LIM ED Quick and easy to install M NT Y L ow installation

More information

SEISMIC RESTRAINT SYSTEM

SEISMIC RESTRAINT SYSTEM 1. GENERAL 1.1. Description: SECTION 16012 SEISMIC RESTRAINT SYSTEM 1.1.1. This specification covers design and installation of seismic bracing and anchorage required for conduit, cable tray, bus duct,

More information

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0)

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0) metal ceilings system 130 modular lay-in tiles (exposed grid) SAS International +44 (0) 118 929 0900 www.sasint.co.uk system 130 information System Description SAS System 130 is a range of lay-in tiles

More information

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

SYSTEM S7-RHOMBOS INSTALLATION MANUAL SYSTEM S7-RHOMBOS INSTALLATION MANUAL GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

ECONO 200 INPLANT OFFICE

ECONO 200 INPLANT OFFICE Warehouse Storage & Material Handling Equipment+ ECONO 200 INPLANT OFFICE INSTALLATION & ASSEMBLY INSTRUCTIONS American Surplus Inc. 1 Noyes Ave. East Providence, RI Phone: (800) 989-7176 Fax: (401) 434-7414

More information

K-H 400 SYSTEM. Tartan Grid

K-H 400 SYSTEM. Tartan Grid K-H 400 SYSTEM Tartan Grid BENEFITS Solution for square and/or rectangular room partitioning Easily installed and removed Grid can be emphasised by using contrasting colours C-profiles can connect to the

More information

BASICS Direct-Attach Ceiling Panels

BASICS Direct-Attach Ceiling Panels INVISACOUSTICS Assembly and Installation Instructions BASICS Direct-Attach Ceiling Panels CEILING PANELS STANDARD ITEMS: Item No. 1212FP Item Name 23-3/4 x 47-3/4 x 3/ No Finish Included w/panels Sold

More information

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post TEST REPORT Rendered to: SENTINEL FENCE AND RAIL For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post Report No: Report Date: 10/23/12 130 Derry Court York, PA 17406-8405

More information

ContainAire TM Applications Guide CONTAINAIRE TM APPLICATIONS GUIDE Montevideo Road Jessup, MD Tel (410)

ContainAire TM Applications Guide CONTAINAIRE TM APPLICATIONS GUIDE Montevideo Road Jessup, MD Tel (410) CONTAINAIRE TM APPLICATIONS GUIDE 1 TABLE OF CONTENTS 1. ContainAire TM Hard Partition. 4 2. ContainAire TM Soft Partition. 17 3. ContainAire TM Dual Sliding Doors. 23 4. ContainAire TM Single Sliding

More information

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide CEILING & WALL SYSTEMS Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide Canopies & Exposed Structures SOUNDSCAPES Acoustical Canopies Product Description SoundScapes are

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

AXIOM Building Perimeter System Assembly and Installation Instructions

AXIOM Building Perimeter System Assembly and Installation Instructions CEILING SYSTEMS AXIOM Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description Axiom Building Perimeter Systems (ABPS) is a pre-engineered perimeter solution to accomplish

More information

SPECIFICATIONS (unless noted otherwise)

SPECIFICATIONS (unless noted otherwise) 2" 150F SYSTEM PROFILE 5 7 8 " NOM. CARRIER SPLICE SEE DETAIL B1.4 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 DETAIL 'A' TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 1 VERTICAL

More information

Installer Guide. Item

Installer Guide. Item Installer Guide Item 17392-01 Required tools and fixings Electric drill (non-impact setting) T-30 Torq bit (wedge type) 8mm hex socket Pozi head drill bit Tape measure Pencil/pen Hammer Tin snips Angle

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3336 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 09 00

More information

6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.

6 MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. 5 7 8 " NOM. 2" TYPICAL SYSTEM SECTION VERTICAL SUPPORT SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. CARRIER SPLICE SEE DETAIL B1.4 6" MAX CARRIER OVERHANG, TYP. 1 12 GA HANGER

More information

ROCKFON SYSTEM ULTRALINE E

ROCKFON SYSTEM ULTRALINE E System description ROCKFON SYSTEM ULTRALINE E Visible grid ceiling system SYSTE F unctional recess allows for the easy integration of partitions, track lighting and signage E15S8 EDGE WAR YEARS IT LIM

More information

JASPER. PAGE 2: 2x2 T-GRID INSTALLATION. PAGE 3: 2x2 SRI SHEETROCK INSTALLATION. PAGE 4: 2x2 IEM INSTALLATION

JASPER. PAGE 2: 2x2 T-GRID INSTALLATION. PAGE 3: 2x2 SRI SHEETROCK INSTALLATION. PAGE 4: 2x2 IEM INSTALLATION 2016 JASPER CM2082 (2x2) PAGE 2: 2x2 T-GRID INSTALLATION PAGE 3: 2x2 SRI SHEETROCK INSTALLATION PAGE 4: 2x2 IEM INSTALLATION PAGE 5: INSTALLATION OF THE EARTHQUAKE CLIPS Drawing: 762300XX_2x2 Rev: A Sheet:

More information

SECTION (09512) - ACOUSTICAL TILE CEILINGS

SECTION (09512) - ACOUSTICAL TILE CEILINGS SECTION 09 51 23 (09512) - ACOUSTICAL TILE CEILINGS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Suspended Metal Grid Systems Complete With Wall Trim 2. Suspended Fiberglass Grid Systems Complete

More information

Wall Panels. Structural wall panel. Architectural wall panel. Cladding wall panel. Sandwich wall panel

Wall Panels. Structural wall panel. Architectural wall panel. Cladding wall panel. Sandwich wall panel Wall Panels Structural wall panel Architectural wall panel Cladding wall panel Sandwich wall panel Wall Panels Assorted styles and colours Reveals and other patterns Painted finish Bolted, welded and knife

More information

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

MASTERSPEC - SHORT FORM. B. See Division 5 Section Metal Stairs for steel tube railings associated with metal stairs. SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated

More information

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F NWCB Technical Document SUSPENDED CEILINGS 401 Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F 10/09 This document has been revised based on current Building Code standards.

More information

American Metal Specialties, Inc.

American Metal Specialties, Inc. American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

OCALA INTERNATIONAL AIRPORT MBI PN: GENERAL AVIATION TERMINAL JANUARY 16, 2018 ADDENDUM-ISSUE

OCALA INTERNATIONAL AIRPORT MBI PN: GENERAL AVIATION TERMINAL JANUARY 16, 2018 ADDENDUM-ISSUE SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Basic Suspension Systems

Basic Suspension Systems CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system

More information

AXIOM Indirect Light Coves

AXIOM Indirect Light Coves AXIOM Indirect Light Coves Assembly and Installation Instructions 1. GENERAL 1.1 Description The Axiom Indirect Light Cove system is a pre-engineered lighting solution designed to be used at a ceiling-to-wall

More information

Fiberstrut Parts Catalogue

Fiberstrut Parts Catalogue Fiberstrut s Catalogue 1 Technical Information Fiberstrut Fabrication The installation of fiberglass channels and accessories is similar to the installation of metallic channels and accessories. All standard

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 095423 - LINEAR METAL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

S7 Taifun Installation Manual

S7 Taifun Installation Manual CEIL ING LIGHTING AMBIENCE S7 Taifun Installation Manual GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe

More information

AXIOM Direct Light Coves Assembly and Installation Instructions

AXIOM Direct Light Coves Assembly and Installation Instructions AXIOM Direct s Assembly and Installation Instructions 1. GENERAL 1.1 Description The Axiom Direct system is a pre-engineered lighting solution designed to be used at a wall condition and integrate with

More information

DONN Suspension Systems

DONN Suspension Systems DONN Suspension Systems CI/SfB from the industry leader u (35) Xh2 DONN grid syst innovation and quality you USG is the world s leading manufacturer of ceiling grid, offering the widest range of profiles

More information

SYSTEM S4-RHOMBOS INSTALLATION MANUAL

SYSTEM S4-RHOMBOS INSTALLATION MANUAL SYSTEM S4-RHOMBOS INSTALLATION MANUAL GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant

More information

Pre-Fabricated Roof Curbs

Pre-Fabricated Roof Curbs Knock Down Curb Assembly Instructions These roof curb assembly instructions are to be used as general guidelines only. Included with shipment are as-built drawings for proper location of sections and channels.

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

USG Ceiling Solutions USG PARALINE BAFFLES LINEAR METAL CEILING SYSTEM SYSTEM GUIDE

USG Ceiling Solutions USG PARALINE BAFFLES LINEAR METAL CEILING SYSTEM SYSTEM GUIDE USG Ceiling Solutions USG PARALINE BAFFLES LINEAR METAL CEILING SYSTEM SYSTEM GUIDE USG PARALINE BAFFLES LINEAR METAL CEILING SYSTEM SYSTEM GUIDE USG Paraline Baffles is a flexible and customizable linear

More information

ROCKFON SYSTEM T24 XL A, E

ROCKFON SYSTEM T24 XL A, E System description ROCKFON SYSTEM T24 XL A, E Visible/Semi-concealed ceiling system Standard A EDGE E very tile is demountable and fewer hangers allow easy access to ceiling voids SYSTE GRP WAR YEARS NT

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1722 Reissued 05/2018 This report is subject to renewal 05/2020. DIVISION: 09 00

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

Report of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists

Report of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists Report of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists 2014 Alberta Building Code - Part 9 2012 British Columbia Building Code - Part 9 2015 National Building Code

More information

Report Of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists

Report Of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists Report Of: RailBlazers Aluminum Railing System Post Attachment Kit for Decks with Wood Joists 2014 Alberta Building Code - Part 9 2012 British Columbia Building Code - Part 9 2015 National Building Code

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Q Line Shelving Bulk Storage Shelving Heavy Duty Reinforced Shelving

Q Line Shelving Bulk Storage Shelving Heavy Duty Reinforced Shelving Q Line Shelving Bulk Storage Shelving Heavy Duty Reinforced Shelving SYSTEMS FOR SUCCESS Q Line Shelving Q Line Shelving is designed for those storage applications that demand strength and versatility.

More information

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 09 51 13 AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general conditions of Contract, including General and Supplementary Conditions and

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

FASTLOCK SUSPENDED CEILING GRID ECOPLUS SYSTEMS. FasTLock SUSPENDED CEILING GRID. Stronger, more durable

FASTLOCK SUSPENDED CEILING GRID ECOPLUS SYSTEMS. FasTLock SUSPENDED CEILING GRID. Stronger, more durable ECOPLUS SYSTEMS FASTLOCK SUSPENDED CEILING GRID FasTLock SUSPENDED CEILING GRID Ver 3.0 Dec. 2011 ECOPLUS SYSTEMS CONTENTS 3: The FasTLock Advantage 4: FasTLock product detail 5: FasTLock 15 product detail

More information

MAC-T Ceiling Grid System 2 Heavy Duty for Cleanroom OPERATION & MAINTENANCE MANUAL. ENVIRCO Technical Support:

MAC-T Ceiling Grid System 2 Heavy Duty for Cleanroom OPERATION & MAINTENANCE MANUAL. ENVIRCO Technical Support: MAC-T Ceiling Grid System OPERATION & MAINTENANCE MANUAL ENVIRCO Technical Support: 800-884-0002 MAC-T Ceiling Grid System Installation & Service Manual Table of Contents Introduction... 3 Tools... 3 Uncrating,

More information

EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE

EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE rondo duo EXPOSED GRID CEILING SYSTEM VARIOUS RONDO DUO COMPONENTS INTRODUCTION Rondo DUO Exposed Grid Ceiling System is a practical ceiling system which

More information

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS) Tectum Inc. 105 South Sixth Street Newark, OH 43055 Phone: (888) 977-9691 Phone: (740) 345-9691 Fax: (800) 832-8869 E-mail: info@tectum.com www.tectum.com This MANU-SPEC utilizes the Construction Specifications

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: Solutions Aluminum Guardrail System with Glass Balustrades

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: Solutions Aluminum Guardrail System with Glass Balustrades TEST REPORT Rendered to: FAIRWAY BUILDING PRODUCTS, LP For: Solutions Aluminum Guardrail System with Glass Balustrades Report No: Report Date: 09/15/10 Revision 1: 09/23/10 130 Derry Court York, PA 17406-8405

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 102239 - FOLDING PANEL PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems. SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Technical Services Information Bureau

Technical Services Information Bureau Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized

More information

System F - Free Span Systems

System F - Free Span Systems System F - Free Span Systems System F 1.1: THERMATEX GN (non) demountable System F 1.2: THERMATEX AW demountable System F 1.3: THERMATEX VT demountable System F 4.1: MONDENA corridor system System F as

More information

system 330 lay-in tiles (c-profile suspension) SAS International +44 (0)

system 330 lay-in tiles (c-profile suspension) SAS International +44 (0) system 0 lay-in tiles (c-profile suspension) SAS International +44 (0) 118 99 0900 www.sasint.co.uk system 0 information System Description SAS System 0, linear or tartan grid, is a lay-in tile system

More information

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SWH Solar Racking Ground Mount Installation Guide

SWH Solar Racking Ground Mount Installation Guide Version 16.02.v1 SWH Solar Racking Ground Mount Installation Guide Installer responsibility The installer is solely responsible for: Complying with all local or national building codes, including any that

More information

Item 442 Metal for Structures

Item 442 Metal for Structures Item 442 Metal for Structures 1. DESCRIPTION 2. MATERIALS Provide structural steel, high-strength bolts, forgings, steel castings, iron castings, wrought iron, steel pipe and tubing, aluminum castings

More information

STRUT METAL FRAMING SYSTEMS

STRUT METAL FRAMING SYSTEMS STRUT METAL FRAMING SYSTEMS CONTENTS STRUT CHANNELS 2 FLAT PLATE FITTINGS 4 ANGLE FITTINGS 6 Z & U FITTINGS 8 BEAM CLAMPS 9 BASE POSTS 11 CANTILEVERS 13 I-BEAM SUPPORTS 15 PROPERTIES OF SECTION PROFILES

More information

Flextray - Accessories

Flextray - Accessories Flextray - 40 Flextray - Protects cable from debris and dust Adds security to cable installation Easy bend-over tabs secure cover to trays Available for 2 (50mm) to 24 (600mm) wide trays Comes in 118 (2997mm)

More information

Missouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS

Missouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS SECTION 102116.19 - PLASTIC SHOWER AND DRESSING COMPARTMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Install Instruction LOOP RECESSED

Install Instruction LOOP RECESSED LOOP RECESSED T F W 604.549.9379 604.549.9555 fluxwerx.com Install Instruction 1 X 1 6" X 1 6" X 1.5 ATTENTION: This installation guide does not apply to Loop Recessed 1x2, 2x2, 1x4, 2x4, 6"x2 and 6"x4.

More information

Section Permanent Beam Grandstands

Section Permanent Beam Grandstands Section 13 34 16 Permanent Beam Grandstands Part 1 GENERAL.1 Section Includes.1 Design, fabrication, engineering and installation of permanent beam grandstand assembly, including the following:.1 Foundations.2

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS ARCHITECTURAL SPECIFICATIONS I. GENERAL 1. System Description: 1.1 Size The raised access floor system shall consist of 600mm x 600mm x 3mm modular steel cement panels/ cementitious panels / cement filled