Electrical Metallic Tubing (EMT) Fittings
|
|
- Della Peters
- 6 years ago
- Views:
Transcription
1 Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe Spacers Ferrous Electrical Metallic Tubing (E.M.T.) shall be of the hot dipped galvanized type conforming to applicable specifications WW-6/ANSI C.98/ANSI C80./UL 797/ CSA C22.2 No. 8. E.M.T. protected solely by enamel shall not be used Where lengths of EMT are coupled together or connected to boxes or enclosures or where EMT is coupled to threaded rigid metal conduit or IMC, fittings approved for intended applications shall be used, and: () Shall be of rugged steel/malleable iron construction electro zinc plated inside/outside including threads. Connector throat shall be bushed with a nylon insulator (2) Shall be of raintight type for installations exposed to weather or wet locations such as Thomas & Betts series TC2A-RT and TK2A-RT () Shall be of concrete tight type for installations in poured concrete such as Thomas & Betts series TC2, TC72, or TK2, 2, 20, and 0 Raintight type fittings may be substituted for concrete tight application. Where electrical metallic tubing and associated fittings are used as part of equipment grounding system: () A bonding type locknut such as Thomas & Betts series 06 shall be installed where hub type fitting terminates into a threadless opening (2) Compression ring type fittings such as Thomas & Betts series 2 and 20 shall be used for terminating and coupling EMT shall be securely fastened in place at intervals as specified by the code using straps, hangers and other supporting assemblies as indicated on plans, and as manufactured by Thomas & Betts, series 476 straps. In wet locations or where supporting surfaces are of absorbent materials vertical and horizontal runs of conduit shall be firmly supported such that there is at least " air space between conduit and supporting surface Spacers and supporting straps shall be of rugged malleable iron or steel construction hot dipped galvanized and conforming to requirements of Canadian Standards Association Standard C22.2 No. 8 as manufactured by Thomas & Betts, series 476 straps and series 0 spacers Series 476 Pipe Straps Series 06 Bonding Locknut Series HT-22 Combination Coupling (Concrete tight) Rigid/IMC to EMT (Set Screw Type) Zinc Die Cast Series TK2-E EMT Coupling (Concrete tight) (Set Screw Type) A-00 Tel: Fax: Tel: Fax:
2 Fittings for Electrical Metallic Tubing (EMT) Compression Type, Raintight 2 Series 20 Series Application To connect and effectively bond electrical metallic tubing to a box or an enclosure To provide a rain tight connection between tubing and the connector To couple ends of tubing Features Rugged all steel construction Rings designed to positively bond conduit to fitting; unique locknut design provides effective bond between fitting and box or enclosure; ground continuity is ensured Nylon insulator firmly secured in place protects conductors, reduces wire pulling effort and prevents thread damage in handling Locknuts are designed with extended reach to lock fitting on to a thin box or an enclosure Locknuts tighten without deformation; will not vibrate loose Standard Material All Steel except Insulator. Insulator Thermoplastic, UL Rated 0 C Standard Finish All Steel Parts Electro Zinc Plated & Chromate Coated Insulator As Molded Range Conduit Size " thru 2" Hub Size " thru 2" NPS Hubs provided with straight pipe threads NPS. Listed/Certified by UL (UL File No. E-692) CSA (LR-4484, LR-8994) Conforms to: UL 4B CSA C22.2 No. 8 NFPA 70 NEMA FB Federal Specification A-A-0 Federal Standard H-28 (Threads) Tel: Fax: Tel: Fax: A-0
3 EMT Raintight Fittings Patented design includes a sealing ring ensuring a 60 raintight seal Distinctive fitting design and gland nut color enables inspectors to visually inspect conformance from a distance no close-up inspection required All-steel construction for rugged, durable installations Sharp teeth on locknuts ensure a solid bond and tight grip on surface of enclosure Does not require disassembly to install Materials, Specifications Material: Steel Body, Steel Locknut Plating: Zinc Plated, Clear Chromate coating Liner: Nylon (for insulated fittings) Threads: Male hub threads NPS Gaskets: Neoprene (black) sold separately Use: Raintight, wet locations, concrete-tight Steel City Raintight EMT Compression Fittings feature a distinctive design and vibrant gland nut color, enabling inspectors to visually inspect conformance from a distance. There's no close-up inspection required! Third Party Certification UL Listed: E-692 Listed Raintight Third Party Standards UL Standard: 4B NEMA: FB- B Peaks L Max L Max A H Peaks B Max H L PKG. QTY. Non-Insulated Compression Connectors TCA-RT " TC2A-RT " TCA-RT " Insulated Compression Connectors TC7A-RT " TC72A-RT " TC7A-RT " NO. SIZE A L PKG. QTY. Compression Couplings TKA-RT " TK2A-RT " TKA-RT " Sealing Gaskets* (sold separately) SR-0 " 0 SR-02 " 0 SR-0 " 0 * Gaskets sold separately. In some jurisdictions, sealing gaskets are not required when installed in a threaded opening. Also, a connector assembled in the bottom of a box or enclosure may be considered by code to be located (placed) so that water will not enter the enclosure at the knockout interface (NEC 4. (A)). In this instance, the sealing O-ring may not be required. Consult with the local authority having jurisdiction. Neoprene is a trademark of DuPont Dow Elastomers L.L.C. EMT Connectors Nylon Insulated EMT Couplings EMT Connectors 2 " " " 7 42 " " " U.L. File No. E 904 CSA File No " " 2 20 " " " " 2 7 U.L. File No. E 904 CSA File No " 9 22 " 2 2 " 42 " 2 2 " " 2 2 T&B E.M.T. (thinwall) fittings comply with Federal Spec. WF408B. U.L. File No. E 904 CSA File No A-02 Tel: Fax: Tel: Fax:
4 Insulated for safe, simple installation in cramped locations or tight corners! Short Elbows Insulated* Ideal for applications where large radius conduit elbows won t fit or would appear unworkmanlike Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction UL rated 0 C C 4240 " 7 s TB " " " " " UL Listed and CSA Certified raintight. UL File No. E 0904 Ideal for cramped locations or tight corners! Short Elbows Malleable Iron* Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction C 420 " 7 s 7 42 " " " " " UL Listed and CSA Certified raintight. UL File No. E 0904 For connecting EMT to threaded rigid and intermediate metal conduit. Combination Coupling Steel* For XJG Conduit Expansion Couplings for EMT see page A-2 0-TB " " 2 " 9 2 UL Listed and CSA Certified rain tight. UL File No. E 0904 * All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by the NEC; Class I, Div. 2; Class II, Div. & 2; Class III, Div. & 2, 02-4(a)(b); 0-(a)(b). Tel: Fax: Tel: Fax: A-0
5 Snap-on design holds strap in place! Pipe Straps Steel Oval Hole for Screw Size (C) NO. SIZE A B C (BOLT HOLE) 49 " " 2 46 " " 2 7 Elongated bolt hole makes alignment easy, even when holes in mounting surface are out of alignment Available in " to 2" sizes 46 " 464 2" 4 Not UL Listed. and 4484 Designed to fit each size of conduit snugly! Pipe Straps Malleable Iron Oval Hole for Screw Size (C) NO. SIZE A B C (BOLT HOLE) 476 " " " 479 " 480 " 4 High reinforcing ribs on each side increase strength and reduce weight Hot-dipped galvanized finish 48 2" " 28 " " " 8 7 Not UL Listed. and Eliminates the need for costly offset-bending of conduit to prevent corrosive moisture traps when conduit is mounted directly to a surface! Pipe Spacers 0 Used with T&B conduit straps to permit space between conduit and mounting surface Pre-mountable and stackable to eliminate offsetting Malleable iron construction with hot-dipped galvanized finish NO. SIZE A B 0 ", ", " " 7 "- "-2" " " 2 2 "-" 9 9 " " "-4" 7 9 " 2" 4 4 "-"-6" 0 9 " 2 9 " Conforms to NEC 00--C. A-04 Tel: Fax: Tel: Fax:
Specifications Electrical Metallic Tubing (EMT)
T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing
More informationService Entrance Cable Fittings
Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.
More informationMaterials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.
Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon
More informationSECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:
SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.
More informationB. Provide a complete conduit system with associated couplings, connectors, and fittings.
SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED
More informationCable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications
Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber
More information1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.
SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2
More information1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED
LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated
More informationThis product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.
Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral
More informationFig. 1 - Standard Clevis Hanger
Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension
More informationMeter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationTOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations
TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with
More informationSECTION CHAIN-LINK FENCES AND GATES 02821/1
SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where
More informationFig Beam Clamp Retaining Strap (B-Line B3367)
Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized
More informationE-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB
Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2
More informationUNDERGROUND SERVICES SECONDARY
Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-
More informationCOMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE
NOTICE OF VALIDATION INCH-POUND A-A-50552 NOTICE 1 30 October 2001 COMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE A-A-50552, dated 31 May 1995, has been reviewed
More informationINSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS
INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using
More informationCHAPTER 11 CONDUITS AND FITTINGS
CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1
More informationCONDUITS AND FITTINGS
CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit
More informationB. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.
SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Grounding conductors. 2. Grounding connectors. 3. Grounding busbars. 4. Grounding
More informationSuperstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers
Design Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the American Standard Code for Pressure Piping. Hanger Design Pipe hangers are of advanced design
More informationDimensions in Millimeters (Inches) A Bushing Diameter. B Bushing Height
Insulated Grounding for Threadless and Threaded RM IM GI-LS- and I-LS- Series - with luminum Lay-In-Lug for opper or luminum onductors. NE/E: pplications GI-LS Series insulated bushings fasten and ground
More informationMeter Connection Products: Overview
: Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature
More informationA. Product Data shall be provided for each type of product indicated.
32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.
SECTION 26 05 29 HANGERS AND SUPPORTS FOR PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Hangers and supports for electrical equipment and systems. 1.2 DEFINITIONS A. EMT: Electrical
More informationMaterials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.
Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used
More informationMaterials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.
Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used
More informationSECTION SEISMIC CONTROL OSHPD
SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components
More informationRN Optical Termination Panel (RN OTP)
RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationSECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway
More informationPIP PCEPA003 Process Analyzer System Field Installation Guidelines
January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More information4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz
More informationB-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution
DURA-BLOK rooftop supports BRTS-17 B-LINE SERIES DURA-BLOK A complete rooftop support solution DURA-BLOK rooftop solutions support DURA-BLOK supports are made of 100% recycled rubber and are designed to
More informationSAVE THIS INSTRUCTION MANUAL
IS0608UA_Rev B OWNER S MANUAL INSTALLATION & PARTS FOR MODEL NUMBERS: SP0608U - FOR VINYL OR FIBERGLASS POOLS & SPAS Jiffy Niche TM Series Niches Unlike metallic niches, Jiffy Niche TM niches are injection-molded
More information(Condensed from National Electric Code)
WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,
More informationNEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 Table of Contents SECTION 1 Unpacking... 3 1.1 Shipping... 3 1.2 Receiving... 3 SECTION 2 Installation... 3 SECTION 3 Inspection... 4 SECTION 4 Connection... 4 4.1 Neutral Lead... 5 4.2 Ground Lead...
More informationIBC Compliant Seismic Rated Isolators
ISOLATORS IBC Compliant Seismic Rated Isolators Features & Benefits Rugged steel housing is designed to handle high wind and seismic forces. Housing serves as blocking during equipment erection. Top plate
More informationPATHWAYS FOR COMMUNICATIONS SYSTEMS
270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.
More informationTrench Duct Class Catalog 5230CT9601R10/08
5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11
More informationWall studs. Wall Studs
15 Box To Stud Fastener Attaches with screws to metal studs. BB1 supports electrical box. BG series features Guide-Rite design. BP series features push-type design. 78101118145 BB1 Electrical Box 100 Support
More informationSECTION GROUNDING AND BONDING
SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and
More informationa gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Lake Park, GA Coats, NC
a gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Coats, NC Lake Park, GA Product Return Policy POLICIES All spiral, oval and rectangular duct products are made to order. Items cannot be cancelled once
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationSECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.
SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationSECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to
More informationSECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE
More informationWIRING METHODS CHAPTER 38
CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2
More informationSeries 2000PV Mechanical Joint Restraint for PVC Pipe
Series 2000PV Mechanical Joint Restraint for PVC Pipe Features and Applications: For restraining plain end PVC pipe at mechanical joint fittings and appurtenances Sizes 3 inch through 36 inch Sizes 42
More informationBulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators
Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...
More informationSpecification Lightning Protection Systems
Specification Lightning Protection Systems General: Summary A) This Section specifies the lightning protection system for the building(s) or structure(s). This system provides safety for the building and
More informationMERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing
MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,
More informationCHAIN LINK FENCES AND GATES
SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 SUMMARY A. Alternate Material for Fence Post and Framing Material: Where schedule 40 galvanized steel is specified, the following will be accepted:
More informationMyers Hubs. Applications: Features: Standard Materials: Certifications and Compliances: Standard Finishes: Options: Conduit Hubs.
pplications: Features: Certifications and Compliances: Standard Materials: Standard Finishes: Options: Description Suffix CP 56 www.crouse-hinds.com US: 1-866-764-5454 CN: 1-800-265-0502 Copyright 2015
More informationContinental Industries METER RISERS or FAX Visit
Continental Industries METER RISERS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationLarge cable sizes stronger than pipe/strut
Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant
More informationKwikon Electrical Nonmetallic Tubing & Fittings. Complete concrete-tight system. Approved for use in fire-rated floor/ceiling assemblies
E L E C T R I C A L S Y S T E M S Kwikon Electrical Nonmetallic Tubing & Fittings Easy Installation Complete concrete-tight system Approved for use in fire-rated floor/ceiling assemblies www.kraloyfittings.com
More informationNorthpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017
SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationCity and County of San Francisco CONTRACT No A SFO - Data Center, Building 60 SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Cable Trays for Communications Cabling 1. Cable Trays 2. Cable Runways 3. Basket Tray B. Cable Tray Support
More informationSECTION I -- IRONWORK
SECTION I -- IRONWORK CONTENTS PAGE 1. GENERAL... I-2 1.1. Introduction... I-2 2. REQUIREMENTS... I-2 2.1. General... I-2 2.2. Auxiliary Framing... I-2 2.3. High Seismic Risk Zone Requirements... I-3 2.4.
More informationFLEXTRAY Wire Basket - Splicing Accessories
D-7 B-Line series Cable Tray Systems Washer is staked to bolt, holding part stationary during installation Fewer parts to handle For use with all tray widths and sizes Finishes : EG, BLE BLE suffix indicates
More informationINTER-BUILDING CONDUIT & MANHOLE SYSTEM. Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6
UNIVERSITY CONTACT: Network Services (302) 831-3722 INTER-BUILDING CONDUIT & MANHOLE SYSTEM Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6 A. MATERIALS AND
More informationNotes Changed note Date. 1 (A) Changed template 09 / 07 / 2008
Revisions Notes Changed note Date 1 (A) Changed template 09 / 07 / 2008 2 Changed template. Clause 12.5.4.1 hot-rolled steel added. Clause 12.5.4.2, 12.5.2.4, 12.5.3.4, 12.5.4.4, 12.5.5.4, 12.5.6.4, 12.5.7.4
More informationPIPE AND TUBE RAILINGS
SECTION 05521 - PIPE AND TUBE RAILINGS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDIVISION 1100 TRAFFIC
SECTION 1102 STREET LIGHTING GENERAL INFORMATION The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the
More informationCom-Tray. Under Floor
Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting
More informationProduct Specifications MRI Trench Duct
NOVA Energy & Automation Product Specifications MRI Trench Duct Model AT Aluminum Non Ferrous 03 January 2012 Product 1. Non Ferrous Large Capacity Trench (Floor) Duct Non Ferrous (Aluminum) Large capacity
More informationMODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.
Installation, Operation, and Maintenance Instructions MODEL 3200 / 3201 March 2002 CONTENTS 1.0 GENERAL 1.1 Model Number ----------------------------------------------------------------------------------------------
More informationModel # 358-R48. 7/7/2011 Page 1 of 11
Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationSECTION ACOUSTICAL PANEL CEILINGS
SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES
More information2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical
ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel
More informationTECHNICAL RANGE. The Complete Pipe Fitting s Handbook
TECHNICAL RANGE The Complete Pipe Fitting s Handbook CONTENTS Compression Fittings Introduction Copper Tubing for Economy Making a Compression Joint Compression Fittings Gate Valves Stop Taps Capillary
More informationLiner Replacement Instructions:
Liner Replacement Instructions: Before beginning the replacement procedure... Be sure to disconnect electrical service to all of your electrical components of the pool. Use extreme caution when working
More informationSECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS
SECTION 02620 PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances
More informationGrounding & Bonding A Global Leader in Innovative...
Grounding & Bonding A Global Leader in Innovative... Wire & Cable Management Cable Protection Systems Power Connection & Control Safety Technology Thomas & Betts Solution Sets An improperly installed or
More informationITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION
SECTION 74 AIRPORT OBSTRUCTION LIGHTS (FAA L-119) 74-1 GENERAL The Contractor shall perform all work required by the plans and specifications for construction of obstruction lights in accordance with the
More informationMASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
More informationPEN SEAL. Pipe Penetration Seals
PEN SEAL Pipe Penetration Seals PROCO s Pipe Penetration Seals have been designed to assist in achieving an efficient, low-cost mechanical seal between any Electrical Conduit, Concrete, Cast Iron, Steel,
More informationWelding Accessories
Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent
More informationElectrical Nonmetallic Tubing & Fittings
Electrical Nonmetallic Tubing & Fittings E L E C T R I C A L S Y S T E M S ELECTRICAL NONMETALLIC TUBING & FITTINGS Easy installation Complete concrete-tight system Approved for use in fire-rated floor/ceiling
More informationTEMPORARY METER POLE INSTALLATION
TEMPARY METER POLE INSTALLATION MEMBER PROVIDED Location to be made by REMC within 50' of our transformer or existing service Temporary pole to be properly braced 24" 3 wire weatherhead (located 24" from
More informationFS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.
S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationRead Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED
Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are
More informationAir flue duct for use with ecotec boilers
For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation
More informationHeight Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w
Series Optics Mounting Lamping / Wattage Finish Voltage SAMG Saturn Magnum MR Type V MTR* 6 Refractor Refractor is an integral part of the fixture and is not an option. Project: Type: SAMG MR Series Optics
More informationAll applicable equipment trip settings must be checked and recorded on the appropriate record sheet.
EXHEAT Electric Heaters and Control Systems Instructions for Completion and Submission of Commissioning Records and Associated Start-up Certificate. It is the responsibility of the installer and end user
More informationBUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466
BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein
More informationWelcome to Douglas County PUD
Welcome to Douglas County PUD We are committed to providing the best possible utility services at the lowest possible cost consistent with sound business principles. To better serve you, please fill out
More informationFIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC
TABLE OF CONTENTS Pictorial Index Product Recommendations Water Closet Carriers Matching Water Closet & Carrier Closet Carrier Selection & Battery Set-Up Stud & Nipple Adjustment to Finished Wall Anchoring
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationSection 2 Supplemental Specification 2.11 High Tension Cable Barrier
2.11 HIGH TENSION CABLE BARRIER 2.11.1 GENERAL This Work consists of the supply, installation, removal, disposal and reinstallation of High Tension Cable Barrier (HTCB) system. 2.11.2 DEFINITIONS AND INTERPRETATION
More information