1 Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe Spacers Ferrous Electrical Metallic Tubing (E.M.T.) shall be of the hot dipped galvanized type conforming to applicable specifications WW-6/ANSI C.98/ANSI C80./UL 797/ CSA C22.2 No. 8. E.M.T. protected solely by enamel shall not be used Where lengths of EMT are coupled together or connected to boxes or enclosures or where EMT is coupled to threaded rigid metal conduit or IMC, fittings approved for intended applications shall be used, and: () Shall be of rugged steel/malleable iron construction electro zinc plated inside/outside including threads. Connector throat shall be bushed with a nylon insulator (2) Shall be of raintight type for installations exposed to weather or wet locations such as Thomas & Betts series TC2A-RT and TK2A-RT () Shall be of concrete tight type for installations in poured concrete such as Thomas & Betts series TC2, TC72, or TK2, 2, 20, and 0 Raintight type fittings may be substituted for concrete tight application. Where electrical metallic tubing and associated fittings are used as part of equipment grounding system: () A bonding type locknut such as Thomas & Betts series 06 shall be installed where hub type fitting terminates into a threadless opening (2) Compression ring type fittings such as Thomas & Betts series 2 and 20 shall be used for terminating and coupling EMT shall be securely fastened in place at intervals as specified by the code using straps, hangers and other supporting assemblies as indicated on plans, and as manufactured by Thomas & Betts, series 476 straps. In wet locations or where supporting surfaces are of absorbent materials vertical and horizontal runs of conduit shall be firmly supported such that there is at least " air space between conduit and supporting surface Spacers and supporting straps shall be of rugged malleable iron or steel construction hot dipped galvanized and conforming to requirements of Canadian Standards Association Standard C22.2 No. 8 as manufactured by Thomas & Betts, series 476 straps and series 0 spacers Series 476 Pipe Straps Series 06 Bonding Locknut Series HT-22 Combination Coupling (Concrete tight) Rigid/IMC to EMT (Set Screw Type) Zinc Die Cast Series TK2-E EMT Coupling (Concrete tight) (Set Screw Type) A-00 Tel: Fax: Tel: Fax:

2 Fittings for Electrical Metallic Tubing (EMT) Compression Type, Raintight 2 Series 20 Series Application To connect and effectively bond electrical metallic tubing to a box or an enclosure To provide a rain tight connection between tubing and the connector To couple ends of tubing Features Rugged all steel construction Rings designed to positively bond conduit to fitting; unique locknut design provides effective bond between fitting and box or enclosure; ground continuity is ensured Nylon insulator firmly secured in place protects conductors, reduces wire pulling effort and prevents thread damage in handling Locknuts are designed with extended reach to lock fitting on to a thin box or an enclosure Locknuts tighten without deformation; will not vibrate loose Standard Material All Steel except Insulator. Insulator Thermoplastic, UL Rated 0 C Standard Finish All Steel Parts Electro Zinc Plated & Chromate Coated Insulator As Molded Range Conduit Size " thru 2" Hub Size " thru 2" NPS Hubs provided with straight pipe threads NPS. Listed/Certified by UL (UL File No. E-692) CSA (LR-4484, LR-8994) Conforms to: UL 4B CSA C22.2 No. 8 NFPA 70 NEMA FB Federal Specification A-A-0 Federal Standard H-28 (Threads) Tel: Fax: Tel: Fax: A-0

3 EMT Raintight Fittings Patented design includes a sealing ring ensuring a 60 raintight seal Distinctive fitting design and gland nut color enables inspectors to visually inspect conformance from a distance no close-up inspection required All-steel construction for rugged, durable installations Sharp teeth on locknuts ensure a solid bond and tight grip on surface of enclosure Does not require disassembly to install Materials, Specifications Material: Steel Body, Steel Locknut Plating: Zinc Plated, Clear Chromate coating Liner: Nylon (for insulated fittings) Threads: Male hub threads NPS Gaskets: Neoprene (black) sold separately Use: Raintight, wet locations, concrete-tight Steel City Raintight EMT Compression Fittings feature a distinctive design and vibrant gland nut color, enabling inspectors to visually inspect conformance from a distance. There's no close-up inspection required! Third Party Certification UL Listed: E-692 Listed Raintight Third Party Standards UL Standard: 4B NEMA: FB- B Peaks L Max L Max A H Peaks B Max H L PKG. QTY. Non-Insulated Compression Connectors TCA-RT " TC2A-RT " TCA-RT " Insulated Compression Connectors TC7A-RT " TC72A-RT " TC7A-RT " NO. SIZE A L PKG. QTY. Compression Couplings TKA-RT " TK2A-RT " TKA-RT " Sealing Gaskets* (sold separately) SR-0 " 0 SR-02 " 0 SR-0 " 0 * Gaskets sold separately. In some jurisdictions, sealing gaskets are not required when installed in a threaded opening. Also, a connector assembled in the bottom of a box or enclosure may be considered by code to be located (placed) so that water will not enter the enclosure at the knockout interface (NEC 4. (A)). In this instance, the sealing O-ring may not be required. Consult with the local authority having jurisdiction. Neoprene is a trademark of DuPont Dow Elastomers L.L.C. EMT Connectors Nylon Insulated EMT Couplings EMT Connectors 2 " " " 7 42 " " " U.L. File No. E 904 CSA File No " " 2 20 " " " " 2 7 U.L. File No. E 904 CSA File No " 9 22 " 2 2 " 42 " 2 2 " " 2 2 T&B E.M.T. (thinwall) fittings comply with Federal Spec. WF408B. U.L. File No. E 904 CSA File No A-02 Tel: Fax: Tel: Fax:

4 Insulated for safe, simple installation in cramped locations or tight corners! Short Elbows Insulated* Ideal for applications where large radius conduit elbows won t fit or would appear unworkmanlike Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction UL rated 0 C C 4240 " 7 s TB " " " " " UL Listed and CSA Certified raintight. UL File No. E 0904 Ideal for cramped locations or tight corners! Short Elbows Malleable Iron* Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction C 420 " 7 s 7 42 " " " " " UL Listed and CSA Certified raintight. UL File No. E 0904 For connecting EMT to threaded rigid and intermediate metal conduit. Combination Coupling Steel* For XJG Conduit Expansion Couplings for EMT see page A-2 0-TB " " 2 " 9 2 UL Listed and CSA Certified rain tight. UL File No. E 0904 * All items shown on this page are suitable for use in hazardous locations where general purpose equipment is specifically permitted by the NEC; Class I, Div. 2; Class II, Div. & 2; Class III, Div. & 2, 02-4(a)(b); 0-(a)(b). Tel: Fax: Tel: Fax: A-0

5 Snap-on design holds strap in place! Pipe Straps Steel Oval Hole for Screw Size (C) NO. SIZE A B C (BOLT HOLE) 49 " " 2 46 " " 2 7 Elongated bolt hole makes alignment easy, even when holes in mounting surface are out of alignment Available in " to 2" sizes 46 " 464 2" 4 Not UL Listed. and 4484 Designed to fit each size of conduit snugly! Pipe Straps Malleable Iron Oval Hole for Screw Size (C) NO. SIZE A B C (BOLT HOLE) 476 " " " 479 " 480 " 4 High reinforcing ribs on each side increase strength and reduce weight Hot-dipped galvanized finish 48 2" " 28 " " " 8 7 Not UL Listed. and Eliminates the need for costly offset-bending of conduit to prevent corrosive moisture traps when conduit is mounted directly to a surface! Pipe Spacers 0 Used with T&B conduit straps to permit space between conduit and mounting surface Pre-mountable and stackable to eliminate offsetting Malleable iron construction with hot-dipped galvanized finish NO. SIZE A B 0 ", ", " " 7 "- "-2" " " 2 2 "-" 9 9 " " "-4" 7 9 " 2" 4 4 "-"-6" 0 9 " 2 9 " Conforms to NEC 00--C. A-04 Tel: Fax: Tel: Fax:

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

COMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE

COMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE NOTICE OF VALIDATION INCH-POUND A-A-50552 NOTICE 1 30 October 2001 COMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE A-A-50552, dated 31 May 1995, has been reviewed

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

CHAPTER 11 CONDUITS AND FITTINGS

CHAPTER 11 CONDUITS AND FITTINGS CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1

More information

CONDUITS AND FITTINGS

CONDUITS AND FITTINGS CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit

More information

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83. SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Grounding conductors. 2. Grounding connectors. 3. Grounding busbars. 4. Grounding

More information

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers Design Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the American Standard Code for Pressure Piping. Hanger Design Pipe hangers are of advanced design

More information

Dimensions in Millimeters (Inches) A Bushing Diameter. B Bushing Height

Dimensions in Millimeters (Inches) A Bushing Diameter. B Bushing Height Insulated Grounding for Threadless and Threaded RM IM GI-LS- and I-LS- Series - with luminum Lay-In-Lug for opper or luminum onductors. NE/E: pplications GI-LS Series insulated bushings fasten and ground

More information

Meter Connection Products: Overview

Meter Connection Products: Overview : Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems. SECTION 26 05 29 HANGERS AND SUPPORTS FOR PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Hangers and supports for electrical equipment and systems. 1.2 DEFINITIONS A. EMT: Electrical

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

RN Optical Termination Panel (RN OTP)

RN Optical Termination Panel (RN OTP) RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

PIP PCEPA003 Process Analyzer System Field Installation Guidelines January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution DURA-BLOK rooftop supports BRTS-17 B-LINE SERIES DURA-BLOK A complete rooftop support solution DURA-BLOK rooftop solutions support DURA-BLOK supports are made of 100% recycled rubber and are designed to

More information

SAVE THIS INSTRUCTION MANUAL

SAVE THIS INSTRUCTION MANUAL IS0608UA_Rev B OWNER S MANUAL INSTALLATION & PARTS FOR MODEL NUMBERS: SP0608U - FOR VINYL OR FIBERGLASS POOLS & SPAS Jiffy Niche TM Series Niches Unlike metallic niches, Jiffy Niche TM niches are injection-molded

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS 1 Table of Contents SECTION 1 Unpacking... 3 1.1 Shipping... 3 1.2 Receiving... 3 SECTION 2 Installation... 3 SECTION 3 Inspection... 4 SECTION 4 Connection... 4 4.1 Neutral Lead... 5 4.2 Ground Lead...

More information

IBC Compliant Seismic Rated Isolators

IBC Compliant Seismic Rated Isolators ISOLATORS IBC Compliant Seismic Rated Isolators Features & Benefits Rugged steel housing is designed to handle high wind and seismic forces. Housing serves as blocking during equipment erection. Top plate

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

Wall studs. Wall Studs

Wall studs. Wall Studs 15 Box To Stud Fastener Attaches with screws to metal studs. BB1 supports electrical box. BG series features Guide-Rite design. BP series features push-type design. 78101118145 BB1 Electrical Box 100 Support

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

a gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Lake Park, GA Coats, NC

a gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Lake Park, GA Coats, NC a gray co. SPIRAL, OVAL & RECTANGULAR DUCT CATALOG Coats, NC Lake Park, GA Product Return Policy POLICIES All spiral, oval and rectangular duct products are made to order. Items cannot be cancelled once

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories. SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE

More information

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

Series 2000PV Mechanical Joint Restraint for PVC Pipe

Series 2000PV Mechanical Joint Restraint for PVC Pipe Series 2000PV Mechanical Joint Restraint for PVC Pipe Features and Applications: For restraining plain end PVC pipe at mechanical joint fittings and appurtenances Sizes 3 inch through 36 inch Sizes 42

More information

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...

More information

Specification Lightning Protection Systems

Specification Lightning Protection Systems Specification Lightning Protection Systems General: Summary A) This Section specifies the lightning protection system for the building(s) or structure(s). This system provides safety for the building and

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 SUMMARY A. Alternate Material for Fence Post and Framing Material: Where schedule 40 galvanized steel is specified, the following will be accepted:

More information

Myers Hubs. Applications: Features: Standard Materials: Certifications and Compliances: Standard Finishes: Options: Conduit Hubs.

Myers Hubs. Applications: Features: Standard Materials: Certifications and Compliances: Standard Finishes: Options: Conduit Hubs. pplications: Features: Certifications and Compliances: Standard Materials: Standard Finishes: Options: Description Suffix CP 56 www.crouse-hinds.com US: 1-866-764-5454 CN: 1-800-265-0502 Copyright 2015

More information

Continental Industries METER RISERS or FAX Visit

Continental Industries METER RISERS or FAX Visit Continental Industries METER RISERS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

Large cable sizes stronger than pipe/strut

Large cable sizes stronger than pipe/strut Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant

More information

Kwikon Electrical Nonmetallic Tubing & Fittings. Complete concrete-tight system. Approved for use in fire-rated floor/ceiling assemblies

Kwikon Electrical Nonmetallic Tubing & Fittings. Complete concrete-tight system. Approved for use in fire-rated floor/ceiling assemblies E L E C T R I C A L S Y S T E M S Kwikon Electrical Nonmetallic Tubing & Fittings Easy Installation Complete concrete-tight system Approved for use in fire-rated floor/ceiling assemblies www.kraloyfittings.com

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

City and County of San Francisco CONTRACT No A SFO - Data Center, Building 60 SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

City and County of San Francisco CONTRACT No A SFO - Data Center, Building 60 SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Cable Trays for Communications Cabling 1. Cable Trays 2. Cable Runways 3. Basket Tray B. Cable Tray Support

More information

SECTION I -- IRONWORK

SECTION I -- IRONWORK SECTION I -- IRONWORK CONTENTS PAGE 1. GENERAL... I-2 1.1. Introduction... I-2 2. REQUIREMENTS... I-2 2.1. General... I-2 2.2. Auxiliary Framing... I-2 2.3. High Seismic Risk Zone Requirements... I-3 2.4.

More information

FLEXTRAY Wire Basket - Splicing Accessories

FLEXTRAY Wire Basket - Splicing Accessories D-7 B-Line series Cable Tray Systems Washer is staked to bolt, holding part stationary during installation Fewer parts to handle For use with all tray widths and sizes Finishes : EG, BLE BLE suffix indicates

More information

INTER-BUILDING CONDUIT & MANHOLE SYSTEM. Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6

INTER-BUILDING CONDUIT & MANHOLE SYSTEM. Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6 UNIVERSITY CONTACT: Network Services (302) 831-3722 INTER-BUILDING CONDUIT & MANHOLE SYSTEM Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6 A. MATERIALS AND

More information

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008 Revisions Notes Changed note Date 1 (A) Changed template 09 / 07 / 2008 2 Changed template. Clause 12.5.4.1 hot-rolled steel added. Clause 12.5.4.2, 12.5.2.4, 12.5.3.4, 12.5.4.4, 12.5.5.4, 12.5.6.4, 12.5.7.4

More information

PIPE AND TUBE RAILINGS

PIPE AND TUBE RAILINGS SECTION 05521 - PIPE AND TUBE RAILINGS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DIVISION 1100 TRAFFIC

DIVISION 1100 TRAFFIC SECTION 1102 STREET LIGHTING GENERAL INFORMATION The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

Product Specifications MRI Trench Duct

Product Specifications MRI Trench Duct NOVA Energy & Automation Product Specifications MRI Trench Duct Model AT Aluminum Non Ferrous 03 January 2012 Product 1. Non Ferrous Large Capacity Trench (Floor) Duct Non Ferrous (Aluminum) Large capacity

More information

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4. Installation, Operation, and Maintenance Instructions MODEL 3200 / 3201 March 2002 CONTENTS 1.0 GENERAL 1.1 Model Number ----------------------------------------------------------------------------------------------

More information

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 358-R48. 7/7/2011 Page 1 of 11 Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES

More information

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8 and 1/4 NPT. Features. Construction. Electrical ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel

More information

TECHNICAL RANGE. The Complete Pipe Fitting s Handbook

TECHNICAL RANGE. The Complete Pipe Fitting s Handbook TECHNICAL RANGE The Complete Pipe Fitting s Handbook CONTENTS Compression Fittings Introduction Copper Tubing for Economy Making a Compression Joint Compression Fittings Gate Valves Stop Taps Capillary

More information

Liner Replacement Instructions:

Liner Replacement Instructions: Liner Replacement Instructions: Before beginning the replacement procedure... Be sure to disconnect electrical service to all of your electrical components of the pool. Use extreme caution when working

More information

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS SECTION 02620 PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances

More information

Grounding & Bonding A Global Leader in Innovative...

Grounding & Bonding A Global Leader in Innovative... Grounding & Bonding A Global Leader in Innovative... Wire & Cable Management Cable Protection Systems Power Connection & Control Safety Technology Thomas & Betts Solution Sets An improperly installed or

More information

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION SECTION 74 AIRPORT OBSTRUCTION LIGHTS (FAA L-119) 74-1 GENERAL The Contractor shall perform all work required by the plans and specifications for construction of obstruction lights in accordance with the

More information

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

MASTERSPEC - SHORT FORM. B. See Division 5 Section Metal Stairs for steel tube railings associated with metal stairs. SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated

More information

PEN SEAL. Pipe Penetration Seals

PEN SEAL. Pipe Penetration Seals PEN SEAL Pipe Penetration Seals PROCO s Pipe Penetration Seals have been designed to assist in achieving an efficient, low-cost mechanical seal between any Electrical Conduit, Concrete, Cast Iron, Steel,

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

Electrical Nonmetallic Tubing & Fittings

Electrical Nonmetallic Tubing & Fittings Electrical Nonmetallic Tubing & Fittings E L E C T R I C A L S Y S T E M S ELECTRICAL NONMETALLIC TUBING & FITTINGS Easy installation Complete concrete-tight system Approved for use in fire-rated floor/ceiling

More information

TEMPORARY METER POLE INSTALLATION

TEMPORARY METER POLE INSTALLATION TEMPARY METER POLE INSTALLATION MEMBER PROVIDED Location to be made by REMC within 50' of our transformer or existing service Temporary pole to be properly braced 24" 3 wire weatherhead (located 24" from

More information

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction. S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w Series Optics Mounting Lamping / Wattage Finish Voltage SAMG Saturn Magnum MR Type V MTR* 6 Refractor Refractor is an integral part of the fixture and is not an option. Project: Type: SAMG MR Series Optics

More information

All applicable equipment trip settings must be checked and recorded on the appropriate record sheet.

All applicable equipment trip settings must be checked and recorded on the appropriate record sheet. EXHEAT Electric Heaters and Control Systems Instructions for Completion and Submission of Commissioning Records and Associated Start-up Certificate. It is the responsibility of the installer and end user

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

Welcome to Douglas County PUD

Welcome to Douglas County PUD Welcome to Douglas County PUD We are committed to providing the best possible utility services at the lowest possible cost consistent with sound business principles. To better serve you, please fill out

More information

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC TABLE OF CONTENTS Pictorial Index Product Recommendations Water Closet Carriers Matching Water Closet & Carrier Closet Carrier Selection & Battery Set-Up Stud & Nipple Adjustment to Finished Wall Anchoring

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier 2.11 HIGH TENSION CABLE BARRIER 2.11.1 GENERAL This Work consists of the supply, installation, removal, disposal and reinstallation of High Tension Cable Barrier (HTCB) system. 2.11.2 DEFINITIONS AND INTERPRETATION

More information