DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS

Size: px
Start display at page:

Download "DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS"

Transcription

1 Demilec Inc Galleria Drive Arlington Texas USA Tel: Fax: info@demilecusa.com website: APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 14/5166 Product Sheet 3 DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS This Agrément Certificate Product Sheet (1) relates to Sealection Agribalance Insulation for External Walls, for use as a spray-applied in-situ thermal insulation for external walls of new and existing dwellings or similar buildings. It can be installed either between the inner leaf studs of conventional timber-frame cavity walls with a masonry outer skin, or applied to the internal surface of external solid masonry walls in combination with a dry-lining system. (1) Hereinafter referred to as Certificate. CERTIFICATION INCLUDES: factors relating to compliance with Building Regulations where applicable factors relating to additional non-regulatory information where applicable independently verified technical specification assessment criteria and technical investigations design considerations installation guidance regular surveillance of production formal three-yearly review. KEY FACTORS ASSESSED Thermal performance the product has a thermal conductivity ( D )* value of W m 1 K 1 (see section 6). Condensation risk the product has a water vapour resistance factor (μ) of 6. The risk of interstitial condensation will depend on the wall construction and should, therefore, be assessed for each project. A vapour control layer (VCL) should also be used (see section 7). Durability the product will have a life equivalent to that of the structure in which it is incorporated (see section 12). The BBA has awarded this Certificate to the company named above for the product described herein. This product has been assessed by the BBA as being fit for its intended use provided it is installed, used and maintained as set out in this Certificate. On behalf of the British Board of Agrément Date of First issue: 21 October 2014 John Albon Head of Approvals Claire Curtis-Thomas Energy and Ventilation Chief Executive The BBA is a UKAS accredited certification body Number 113. The schedule of the current scope of accreditation for product certification is available in pdf format via the UKAS link on the BBA website at Readers are advised to check the validity and latest issue number of this Agrément Certificate by either referring to the BBA website or contacting the BBA direct. British Board of Agrément tel: Bucknalls Lane fax: Watford clientservices@bba.star.co.uk Herts WD25 9BA 2014 website: Page 1 of 10

2 Regulations In the opinion of the BBA, Sealection Agribalance Insulation for External Walls, if installed and used in accordance with this Certificate, can satisfy or contribute to satisfying the relevant requirements of the following Building Regulations (the presence of a UK map indicates that the subject is related to the Building Regulations in the region or regions of the UK depicted): The Building Regulations 2010 (England and Wales) (as amended) Requirement: C2(c) Resistance to moisture The product can contribute to satisfying this Requirement. See sections 7.1 and 7.4 of this Certificate. Requirement: L1(a)(i) Conservation of fuel and power The product can contribute to satisfying this Requirement. See section 6 of this Certificate. Regulation: 7 Materials and workmanship The product is acceptable. See section 12 and the Installation part of this Certificate. Regulation: 26 CO 2 emission rates for new buildings Regulation: 26A Fabric energy efficiency rates for new dwellings (applicable to England only) Regulation: 26A Primary energy consumption rates for new buildings (applicable to Wales only) Regulation: 26B Fabric performance values for new dwellings (applicable to Wales only) The product can contribute to satisfying these Regulations; however, compensating fabric/services measures may be required. See section 6 of this Certificate. The Building (Scotland) Regulations 2004 (as amended) Regulation: 8(1) Durability, workmanship and fitness of materials The product is acceptable. See section 12 and the Installation part of this Certificate. Regulation: 9 Building standards applicable to construction Standard: 3.15 Condensation The product can contribute to satisfying this Standard, with reference to clauses (1)(2), (1)(2), (1)(2), (1)(2 ) and (1)(2). See sections 7.1 and 7.5 of this Certificate. Standard: 6.1(b) Carbon dioxide emissions Standard: 6.2 Building insulation envelope The product can contribute to satisfying these Standards, with reference to clauses, or parts of, (1), (1), (1)(2), (1), (1)(2), (2), (1)(2), (1), (2), (1)(2), (1), (1)(2), (2) and (1)(2). See section 6 of this Certificate. Standard: 7.1(a)(b) Statement of sustainability The product can contribute to satisfying the relevant requirements of Regulation 9, Standards 1 to 6, and therefore will contribute to a construction meeting at least a bronze level of sustainability as defined in this Standard. See section 6 of this Certificate. Regulation: 12 Building standards applicable to conversions All comments made in relation to the product under Regulation 9, Standards 1 to 6, also apply to this Regulation, with reference to clause (1)(2) and Schedule 6 (1)(2). (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). The Building Regulations (Northern Ireland) 2012 Regulation: 23 Fitness of materials and workmanship The product is acceptable. See section 12 and the Installation part of this Certificate. Regulation: 29 Condensation The product can contribute to satisfying this Regulation. See section 7.1 of this Certificate. Regulation: 39(a)(i) Conservation measures Regulation: 40(2) Target carbon dioxide emission rate The product can contribute to satisfying these Regulations. See section 6 of this Certificate. Construction (Design and Management) Regulations 2007 Construction (Design and Management) Regulations (Northern Ireland) 2007 Information in this Certificate may assist the client, CDM co-ordinator, designer and contractors to address their obligations under these Regulations. See sections: 3 Delivery and site handling (3.1 to 3.3) and 14 Precautions of this Certificate. Page 2 of 10

3 Additional Information NHBC Standards 2014 NHBC accepts the use of Sealection Agribalance Insulation for External Walls, when installed and used in accordance with this Certificate, in relation to NHBC Standards, Chapter 6.1 External masonry walls and Chapter 6.2 External timber framed walls. CE marking The Certificate holder has taken the responsibility of CE marking the product in accordance with harmonised European Standard BS EN : An asterisk (*) appearing in this Certificate indicates that data shown is given in the manufacturer s Declaration of Performance. Technical Specification 1 Description 1.1 Sealection Agribalance Insulation for External Walls is an open cell in-situ formed sprayed semi-rigid polyurethane (PUR) foam insulation, with a density typically between 9.6 kg m 3 to 12.8 kg m The product is available to a single specification, is yellowish in colour and is applied with a hand-held fixed ratio (1:1) volumetric displacement pump spray machine. 1.3 The product can be applied up to a maximum thicknesses of 300 mm. 1.4 The product must be covered with a plasterboard lining, manufactured in accordance with BS EN 520 : Ancillary items used with this product, but outside the scope of this Certificate (which have not been assessed) are: vapour control layer (VCL) gypsum plasterboard timber battens. 2 Manufacture 2.1 The product comprises two liquid components, isocyanate and polyol resin, which are mixed together within the nozzle of the applicator gun, and spray applied using a water blown process. The product fully cures as a semirigid open cell polyurethane foam (PUR) insulation. Quality control checks are carried out on site to check density and appearance. 2.1 As part of the assessment and ongoing surveillance of product quality, the BBA has: agreed with the manufacturer the quality control procedures and product testing to be undertaken assessed and agreed the quality control operated over batches of incoming materials monitored the production process and verified that it is in accordance with the documented process evaluated the process for management of nonconformities checked that equipment has been properly tested and calibrated undertaken to carry out the above measures on a regular basis through a surveillance process, to verify that the specifications and quality control operated by the manufacturer are being maintained. 3 Delivery and site handling 3.1 The two liquid components, isocyanate and polyol, are delivered to site in either 44 gallon drums or 230 gallon totes, capacity bearing the product name, batch number and the BBA logo incorporating the number of this Certificate. 3.2 The components are combustible and must be protected from naked flames and other ignition sources during installation. Drums should be stored in a well-ventilated area, away from possible ignition sources. The drums must be protected from frost and conditioned at temperatures of between 15 C and 30 C prior to use. 3.3 The isocyanate and polyol are classified as harmful and irritant respectively under The Chemicals (Hazard Information and Packaging for Supply) Regulations 2009 (CHIP4)/Classification, Labelling and Packaging of Substances and Mixtures (CLP Regulation) 2009, and the packaging bear the appropriate hazard warning labels. When cured, Sealection Agribalance does not constitute a hazard. Assessment and Technical Investigations The following is a summary of the assessment and technical investigations carried out on Sealection Agribalance Insulation for External Walls. Page 3 of 10

4 Design Considerations 4 Use 4.1 Sealection Agribalance Insulation for External Walls is satisfactory for use in reducing the thermal transmittance (U value) and contributing to the airtightness of external walls of new and existing dwellings or similar buildings. 4.2 The product can be installed: as insulation between the inner leaf studs of conventional timber-frame cavity walls, with a clear cavity and a masonry outer skin, or as insulation applied to the internal surface of solid masonry walls in between timber battens, and finished with plasterboard, as a dry-lining system. 4.3 In all applications the product must be covered by a plasterboard lining (see section 8.3). 4.4 Constructions must be designed in accordance with the relevant recommendations of: BS 5250 : 2011 BS : 2001 BS EN : 2007, and BS EN : 2004 BS EN : 2005 BS EN : 2005 BS EN : 2006 BS EN : 2006 and their relevant UK National Annexes. 4.5 It is essential that construction elements are designed and constructed to incorporate normal precautions against moisture ingress before the application of the product. 4.6 Existing constructions must be in a good state of repair with no evidence of rain penetration or damp. Defects must be made good prior to installation. 4.7 If present, mould or fungal growth must be treated prior to the application of the product. 4.8 Installation must not be carried out until the moisture content of the timber frame is less than 20%. 4.9 The product must not come into direct contact with flue pipes, chimneys or other heat producing appliances (see section 9) The product must not come into contact with zinc or zinc plated elements, as under certain environmental conditions, the foam will accelerate the corrosion of such elements. Zinc or zinc plated elements are used as fixing for timber. In all situations when foam could come in contact with zinc, the zinc must be separated from the foam by covering the zinc plate with a suitable protective coating. The Certificate holder can advise on an appropriate coating for a particular application. The performance of such coating is outside the scope of this Certificate The product forms a strong bond with clean, dry substrates. This should be taken into account when specifying the product or anticipating future alterations To satisfy the requirements of NHBC, a VCL of a type specified in their Standards must be applied behind the plasterboard lining in wall applications. External cavity walls (insulated timber-frame inner skin) 4.13 Services which penetrate the internal plasterboard lining, eg, light switches, power outlets, should be kept to a minimum to limit damage to vapour checks. In addition, any penetrations should be either enclosed in plasterboard or stone mineral wool or suitably tested proprietary fire-rated systems in order to preserve the fire resistance of the wall. External solid masonry walls (insulated dry lining) 4.14 Insulated dry lining systems require careful detailing during installation around doors and windows to achieve a satisfactory surface for finishing. In addition, every attempt should be made to minimise the risk of thermal bridging at reveals and where heavy separating walls are attached to the external wall. New work must be designed to accommodate the thickness of the dry lining, particularly at reveals, heads, sills and in relation to ceiling height. Where the dimensions of fixtures are critical (eg bathrooms) these should be checked before installation Services which penetrate the dry lining, eg, light switches, power outlets, should be kept to a minimum to limit damage to vapour checks. 5 Practicability of installation The product should only be installed by installers who have been trained and approved by the Certificate holder (see also section 13). Page 4 of 10

5 6 Thermal performance 6.1 Calculations of the thermal transmittance (U value) of a wall should be carried out in accordance with BS EN ISO 6946 : 2007, BRE Digest 465 : 2002 and BRE Report BR 443 : 2006 using the declared thermal conductivity ( D )* of W m 1 K The U value of a completed wall will depend on the insulation thickness, the insulating value of the wall components and the internal finish. Example constructions are given in Tables 1 and 2. For improved energy or carbon savings, designers should consider appropriate fabric and/or services measures. Table 1 U values External masonry wall with timber frame inner skin Design U value (W m 2 K 1 ) Sealection Agribalance Insulation thickness required (mm) between 38 x 140 timber studs at 600 mm centres, with additional battens (1) 0.18 (2) 0.19 (2) mm + 25 mm between battens mm + 25 mm between battens mm + 25 mm between battens mm between studs only mm between studs only (1) Wall construction mm thick external brickwork = 0.77 W m 1 K 1, 50 mm clear cavity, breather membrane, 13 mm sheathing board = 0.13 W m 1 K 1, timber studs = 0.13 W m 1 K 1 (15%, maximum depth 140 mm), with additional timber battens (11.8%), vapour control layer, 12.5 mm plasterboard lining = 0.25 W m 1 K 1. (2) For improved thermal/carbon emission performance, additional batten/insulation thicknesses may be considered. Table 2 U values External masonry wall with internal dry lining Design U value (W m 2 K 1 ) Sealection Agribalance Insulation thickness required (mm) between 47 mm wide timber studs at 600 mm centres (1) Junctions 0.18 (2) 0.19 (2) 0.25 (2) 0.26 (2) 0.27 (2) mm between studs mm between studs mm between studs (1) Wall construction 215 mm thick external brickwork = 0.77 W m 1 K 1 (82.7%), bridged with mortar = 0.88 W m 1 K 1 (17.3%), 25 mm clear cavity bridged with 47 mm by 25 mm timber battens at 600 mm centres = 0.13 W m 1 K 1 (7.8%), breather membrane, timber studs = 0.13 W m 1 K 1 (11.8%, maximum depth 150 mm), vapour control layer, 12.5 mm plasterboard lining = 0.25 W m 1 K 1. (2) For improved thermal/carbon emission performance, additional batten/insulation thicknesses may be considered. 6.3 Care must be taken in the overall design and construction of junctions with other elements and openings to minimise thermal bridges and air infiltration. Detailed guidance can be found in the documents supporting the national Building Regulations. 7 Condensation risk Interstitial condensation 7.1 Walls will limit the risk of interstitial condensation adequately when they are designed and constructed in accordance with the relevant parts of BS 5250 : 2011, Annexes D and G. Further guidance may be obtained from BRE Report BR 262 : A VCL must be used. 7.2 For the purposes of assessing the risk of interstitial condensation, a water vapour resistance factor (μ) of 6 should be taken for the product. Page 5 of 10

6 External solid masonry walls (insulated dry lining) 7.3 The risk of summer condensation on the VCL must be considered for solid masonry walls, orientated from ESE through south to WSW, in accordance with section 3.10 of BRE Report BR 262 : Surface condensation 7.4 Walls will limit the risk of surface condensation adequately where the thermal transmittance (U value) does not exceed 0.7 W m 2 K 1 at any point and the junctions with other elements are designed in accordance with the guidance referred to in section 6.3 of this Certificate. 7.5 For buildings in Scotland, constructions will be acceptable where the thermal transmittance (U value) of the wall does not exceed 1.2 W m 2 K 1 at any point, and the walls are designed and constructed in accordance with the relevant parts of BS 5250 : 2011, Annexes D and G. Further guidance may be obtained from BRE Report BR 262 : 2002 and section 6.3 of this Certificate. 8 Behaviour in relation to fire 8.1 The product is classified as Class F* reaction to fire Classification to BS EN : The product is not classified as non-combustible and must be protected from naked flames and other ignition sources during and after installation. 8.2 Elements must incorporate cavity barriers at edges, around openings and at junctions with fire-resisting elements and in cavities in accordance with the relevant provisions of the national Building Regulations and relevant purpose group. The design and installation of cavity barriers must take into account any anticipated differential movement. 8.3 When installed, the product will be contained by a suitable lining board, eg plasterboard, with all joints fully sealed and supported by timber studs or battens. Therefore, it will not contribute to the development stages of a fire. 9 Proximity of flues and appliances 9.1 When installing the product in close proximity to certain flue pipes, chimneys and/or heat producing appliances, the relevant provisions of the national Building Regulations are applicable. England and Wales Approved Document J Scotland Mandatory Standard 3.19 (1)(2) (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). Northern Ireland Technical Booklet L. 9.2 The product must not be installed within 50 mm of heat emitting devices, where the temperature is in excess of 93 C. 10 Materials in contact wiring installations 10.1 The product is compatible with PVC materials in contact De-rating of electric cables should be considered in areas where the product restricts the flow of air. The use of suitable conduit or trunking is recommended. 11 Maintenance The product, once installed does not require any regular maintenance and has suitable durability (see section 12), provided the external wall and waterproof layers are maintained in a weather-tight condition. 12 Durability The durability of the product is satisfactory and will have a life equivalent to that of the structure in which it is incorporated. Installation 13 Approved installers The Certificate holder operates an Approved Installer Scheme for this product, under which the installers are approved, registered and regularly reviewed by the Certificate holder to demonstrate that they are competent to carry out installation of the product in accordance with this Certificate. Details of Approved Installers are available from the Certificate holder. 14 Precautions 14.1 To comply with the requirements of Section 4 of the Health and Safety at Work Act 1974, it is essential that there is an exchange of information between the client and the installer before spray operations commence on any site. Existing health hazards and those brought into the premises by the installer should be discussed and measures agreed to deal with them effectively The process for the installation of the product may produce a build-up of harmful vapours. Installers must wear full personal protection equipment (PPE) when working with the product, including full-face fresh-air supplied respirators, Page 6 of 10

7 protective clothing and gloves. Other trades and personnel must be kept at least four metres away from the applicator while spraying is taking place. The requirements of the Demilec Agribalance Product Application Guide and the product safety data sheets issued to Installers, must be followed at all times Vapours given off by certain components are generally heavier than air and will tend to move to lower parts of the building. These parts should be suitably ventilated If vapour levels need to be measured, methods should be those recommended by the Health and Safety Executive. Certain applications, ie confined spaces, require the use of extractor fans as recommended by the Certificate holder Care should be taken to minimise the degree of overspray generated whilst spraying. This is in the form of a fine mist of particles that can travel considerable distances and will adhere strongly to surfaces they land on. 15 Procedure General 15.1 Building elements to be insulated must be assessed for suitability and any necessary repairs carried out. Elements must be weather-tight before the application of the product. The positioning and access to services should also be considered The product should be stored, handled and applied in accordance with the Certificate holder s instructions and this Certificate The product should be spray applied to clean and dry substrates and built up in layers of up to 300 mm in thickness maximum Once cured, if required the product is trimmed flat using a saw, and covered with the lining board. External cavity walls (insulated timber-frame inner skin) 15.5 The product is sprayed into the cavity formed by the studs and the outer sheathing board. When cured, if the cavity is fully-filled, the excess foam is trimmed flush with the studs and the lining board installed with a VCL with lapped and sealed joints (see Figure 1) Additional timber battens may be applied to the inner face of the timber studs if additional insulation is required, prior to application of the VCL. Figure 1 External cavity wall (timber frame) insulation between studs timber studs breather membrane vcl 50 mm clear cavity plasterboard lining brick outer skin 'Sealection Agribalance' open-cell spray foam insulation in between timber studs external sheathing board External solid masonry walls (insulated dry lining) 15.7 Installation should be in accordance with good dry lining practice and the relevant parts of the Certificate holder s literature Before applying the product, sufficient time must be allowed for damp-proofing treatments, where applied, to dry out the wall (see also, BS 6576 : 2005 for dry lining in conjunction with a chemical damp proof course application) Wallpaper, skirting, picture rails, gloss paint and projecting window boards are to be removed. Page 7 of 10

8 15.10 Pre-treated timber battens of sufficient thickness are mechanically fixed to the wall substrate at maximum 600 mm centres. A breather membrane is applied to the face of the battens and vertical timber stud framing then fitted, with additional studs used around openings and to support heavy horizontal items The product is sprayed into the cavity formed by the vertical timber studs. When cured, if the cavity is fullyfilled, any excess foam is trimmed flush with the timber studs and the plasterboard lining board installed with a VCL with lapped and sealed joints (see Figure 2). Figure 2 External solid masonry wall internal dry lining timber framing 'Sealection Agribalance' open-cell spray foam insulation between vertical timber studs vcl masonry outer skin vertical battens plasterboard clear cavity between breather membrane and out skin breather membrane Technical Investigations 16 Tests Tests were carried out by the BBA on and the results assessed to determine: adhesion to timber substrate after heat ageing and water immersion density water vapour resistivity dimensional stability thermal conductivity. 17 Investigations 17.1 An assessment was made of independent data relating to: thermal conductivity density fire properties dimensional stability A visit was made to a site in progress to assess the methods of application and the material s behaviour in use An opinion was sought from a UKAS-accredited fire authority concerning the fire resistance of the product when used between studs in a conventional steel/timber-frame construction The manufacturing process and quality control procedures were examined. Page 8 of 10

9 Bibliography BS 5250 : 2011 Code of practice for control of condensation in buildings BS 6576 : 2005 Code of practice for diagnosis of rising damp in walls of buildings and installation of chemical damp-proof courses BS : 2001 Workmanship on Building Sites Code of Practice for Masonry BS EN : 2007 Durability of wood and wood-based products Preservative-treated solid wood Classification of preservative penetration and retention BS EN 520 : 2004 Gypsum plasterboards Definitions, requirements and test methods BS EN : 2004 Eurocode 5 : Design of timber structures General Common rules and rules for buildings NA to BS EN : 2004 UK National Annex to Eurocode 5 : Design of timber structures General Common rules and rules for buildings BS EN : 2005 Eurocode 6 : Design of masonry structures General rules for reinforced and unreinforced masonry structures NA to BS EN : 2005 UK National Annex to Eurocode 6 : Design of masonry structures General rules for reinforced and unreinforced masonry structures BS EN : 2005 Eurocode 6 : Design of masonry structures General rules Structural fire design NA to BS EN : 2005 UK National Annex to Eurocode 6 : Design of masonry structures General rules Structural fire design BS EN : 2006 Eurocode 6 : Design of masonry structures Design considerations, selection of materials and execution of masonry NA to BS EN : 2006 UK National Annex to Eurocode 6 : Design of masonry structures Design considerations, selection of materials and execution of masonry BS EN : 2006 Eurocode 6 : Design of masonry structures : Simplified calculation methods for unreinforced masonry structures NA to BS EN : 2006 UK National Annex to Eurocode 6 : Design of masonry structures : Simplified calculation methods for unreinforced masonry structures BS EN : 2007 Fire classification of construction products and building elements Classification using test data from reaction to fire tests BS EN : 2013 Thermal insulating products for buildings In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation BS EN ISO 6946 : 2007 Building components and building elements Thermal resistance and thermal transmittance Calculation method BRE Digest 465 : 2002 U-values for light steel-frame construction BRE Report (BR 262 : 2002) Thermal insulation: avoiding risks BRE Report (BR 443 : 2006) Conventions for U-value calculations Page 9 of 10

10 Conditions of Certification 18 Conditions 18.1 This Certificate: relates only to the product/system that is named and described on the front page is issued only to the company, firm, organisation or person named on the front page no other company, firm, organisation or person may hold or claim that this Certificate has been issued to them is valid only within the UK has to be read, considered and used as a whole document it may be misleading and will be incomplete to be selective is copyright of the BBA is subject to English Law Publications, documents, specifications, legislation, regulations, standards and the like referenced in this Certificate are those that were current and/or deemed relevant by the BBA at the date of issue or reissue of this Certificate This Certificate will remain valid for an unlimited period provided that the product/system and its manufacture and/or fabrication, including all related and relevant parts and processes thereof: are maintained at or above the levels which have been assessed and found to be satisfactory by the BBA continue to be checked as and when deemed appropriate by the BBA under arrangements that it will determine are reviewed by the BBA as and when it considers appropriate The BBA has used due skill, care and diligence in preparing this Certificate, but no warranty is provided In issuing this Certificate, the BBA is not responsible and is excluded from any liability to any company, firm, organisation or person, for any matters arising directly or indirectly from: the presence or absence of any patent, intellectual property or similar rights subsisting in the product/system or any other product/system the right of the Certificate holder to manufacture, supply, install, maintain or market the product/system actual installations of the product/system, including their nature, design, methods, performance, workmanship and maintenance any works and constructions in which the product/system is installed, including their nature, design, methods, performance, workmanship and maintenance any loss or damage, including personal injury, howsoever caused by the product/system, including its manufacture, supply, installation, use, maintenance and removal any claims by the manufacturer relating to CE marking Any information relating to the manufacture, supply, installation, use, maintenance and removal of this product/ system which is contained or referred to in this Certificate is the minimum required to be met when the product/system is manufactured, supplied, installed, used, maintained and removed. It does not purport in any way to restate the requirements of the Health and Safety at Work etc. Act 1974, or of any other statutory, common law or other duty which may exist at the date of issue or reissue of this Certificate; nor is conformity with such information to be taken as satisfying the requirements of the 1974 Act or of any statutory, common law or other duty of care. British Board of Agrément tel: Bucknalls Lane fax: Watford clientservices@bba.star.co.uk Herts WD25 9BA 2014 website: Page 10 of 10

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK) Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR PITCHED ROOFS AND LOFT SPACES

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR PITCHED ROOFS AND LOFT SPACES Demilec Inc. 2925 Galleria Drive Arlington Texas 76011 USA Tel: + 011-817-640-4900 Fax: + 011-817-663-2000 e-mail: info@demilecusa.com website: www.demilecusa.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK) Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

FENTRIM SEALING TAPES

FENTRIM SEALING TAPES SIGA Cover AG Rütmattstrasse 7 Ruswil 6017 Switzerland Tel: 00 41 41 499 69 69 Agrément Certificate e-mail: siga@siga.swiss 16/5378 website: www.siga.swiss Product Sheet 1 SIGA AIR AND WEATHERTIGHTNESS

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL Pittsburgh Corning (UK) Ltd 31-35 Kirby Street Hatton Garden London EC1N 8TE Tel: 020 7492 1731 Fax: 020 7492 1730 e-mail: info@foamglas.co.uk website: www.foamglas.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS)

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS) Xtratherm Ltd Liscarton Industrial Estate Kells Road Navan Co Meath Ireland Tel: 00 353 46 906 6000 Fax: 00 353 46 906 6090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING

More information

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION Ballytherm Ltd Annagh Industrial Park Ballyconnell Co Cavan Ireland Tel: 00 353 49 9527000 Fax: 00 353 49 9527002 e-mail: info@ballytherm.ie website: www.ballytherm.ie APPROVAL INSPECTION TESTING CERTIFICATION

More information

ICYNENE INSULATION H 2 FOAMLITE

ICYNENE INSULATION H 2 FOAMLITE Icynene Inc 6747 Campobello Road Mississauga Ontario L5N 2L7 Canada Tel: 00 1 905 363 4040 Fax: 00 1 905 363 0102 e-mail: info@icynene.com website: www.icynene.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

Agrément Certificate 17/5450 website: Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW

Agrément Certificate   17/5450 website:  Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW Fosroc Limited Drayton Manor Business Park Coleshill Road Tamworth Staffordshire B78 3XN Tel: 01827 262222 Fax: 01827 262444 Agrément Certificate e-mail: enquiryuk@fosroc.com 17/5450 website: www.fosroc.com

More information

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE Capital Valley Plastics Ltd Cwmavon Works Cwmavon Nr Pontypool Gwent NP4 8UW Tel: 01495 772255 Fax: 01495 772251 e-mail: sales@capitalvalleyplastics.com website: www.capitalvalleyplastics.com APPROVAL

More information

THERMABLOK AEROGEL LTD THERMAL INSULATION SYSTEMS THERMABLOK AEROGEL THERMASLIM INTERNAL WALL INSULATION SYSTEMS

THERMABLOK AEROGEL LTD THERMAL INSULATION SYSTEMS THERMABLOK AEROGEL THERMASLIM INTERNAL WALL INSULATION SYSTEMS Intelligent Insulation Ltd The Oasts Church Farm Estates Ulcombe Kent ME17 1DN Tel: 01622 840289 Fax: 0844 7792242 e-mail: info@thermablok.co.uk website: www.thermablok.co.uk APPROVAL INSPECTION TESTING

More information

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS Carpenter Ltd Dinting Lodge Industrial Estate Glossop Derbyshire SK13 6LE Tel: 01457 861141 Fax: 01457 892424 e-mail: sales.uk@carpenter.com website: www.carpenter.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE Timberwise (UK) Ltd 1 Drake Mews Gadbrook Way Gadbrook Park Cheshire CW9 7XF Tel: 01606 333636 Fax: 01606 334748 e-mail: hq@timberwise.co.uk website: www.timberwise.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU)

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU) Xtratherm UK Ltd Park Road Holmewood Industrial Park Holmewood Chesterfield Tel: 0371 222 1033 Fax: 0371 222 1044 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM APPROVAL INSPECTION TESTING CERTIFICATION Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS RIW Ltd Arc House Terrace Road South Binfield Bracknell Berkshire RG42 4PZ Tel: 01344 397777 Fax: 01344 862010 e-mail: technical@riw.co.uk website: www.riw.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

TYVEK CONSTRUCTION MEMBRANES TYVEK REFLEX INSULATING BREATHER MEMBRANE

TYVEK CONSTRUCTION MEMBRANES TYVEK REFLEX INSULATING BREATHER MEMBRANE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY EcoTherm Insulation (UK) Ltd Burnt Mills Industrial Estate Harvey Road Basildon Essex SS13 1QJ Tel: 01702 520166 Fax: 01702 420636 e-mail: info@ecotherm.co.uk website: www.ecotherm.co.uk APPROVAL INSPECTION

More information

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM APPROVAL INSPECTION TESTING CERTIFICATION Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 1DH Tel: 01473 257671 Fax: 01473 230761 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 06/4350 e-mail:

More information

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS Saint Gobain Isover UK Whitehouse Industrial Estate Runcorn Cheshire WA7 3DP Tel: 0115 969 8009 Fax: 0115 945 1948 e-mail: isover.enquiries@saint-gobain.com website: www.isover.co.uk APPROVAL INSPECTION

More information

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8 Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@kingspaninsulation.co.uk website: www.kingspaninsulation.co.uk APPROVAL INSPECTION

More information

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM Xtratherm Limited Kells Road Navan Co Meath, Ireland Tel: 00 353 46 9066000 Fax: 00 353 46 9066090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

RECTICEL INSULATION RECTICEL EUROWALL +

RECTICEL INSULATION RECTICEL EUROWALL + Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010 Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION URSA UK Ltd Crest House 102-104 Church Road Teddington Middlesex TW11 8PY Tel: 0208 977 9697 Fax: 0208 977 9456 e-mail: ursauk@ursa.com website: www.ursa-uk.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 4LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com Agrément Certificate

More information

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK Stirling Lloyd Polychem Ltd Union Bank King Street Knutsford Cheshire WA16 6EF Tel: 01565 633111 Fax: 01565 633555 e-mail: info@stirlinglloyd.com website: www.stirlinglloyd.com APPROVAL INSPECTION TESTING

More information

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com APPROVAL INSPECTION

More information

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM Kompozitor Plastics Development Ltd Széchenyi út 60 Vecsés 2220 Hungary Tel: +36 29 554 600 Fax: +36 29 554 610 e-mail: info@kompozitor.hu website: www.furanflex.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS Valcan Ltd APPROVAL INSPECTION TESTING CERTIFICATION Unit 7 Robins Drive Castlefields Industrial Estate Bridgwater Somerset TA6 4DL Tel: 01278 428 245 Fax: 01278 425 662 TECHNICAL APPROVALS FOR CONSTRUCTION

More information

Agrément Certificate 12/4912 website: Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER

Agrément Certificate   12/4912 website:  Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER Juta a.s. Dukelska 417 544 15 Dvur Kralove n.l Czech Republic Tel: 00 42 0499 314211 Fax: 00 42 0499 314210 Agrément Certificate e-mail: juta@juta.cz 12/4912 website: www.juta.cz Product Sheet 2 This Agrément

More information

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS wedi Systems (UK) Ltd Unit 4 Mercury Park Mercury Way Trafford Park Manchester M41 7LY Tel: 0161 864 2336 Fax: 0161 864 1323 e-mail: info@wedi.co.uk website: www.wedi.co.uk APPROVAL INSPECTION TESTING

More information

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas HAPAS Wavin Ltd Parsonage Way Chippenham Wiltshire SN15 5PN Tel: 01249 766600 Fax: 01249 443286 e-mail: info@wavin.co.uk website: www.wavin.co.uk WAVIN ROAD GULLIES APPROVAL INSPECTION TESTING CERTIFICATION

More information

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung CI/SfB Designated by Government to issue European Technical Approvals Product Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@insulation.kingspan.com

More information

Agrément Certificate 08/4575 website: Product Sheet 1

Agrément Certificate   08/4575 website:  Product Sheet 1 Specialist Tiling Supplies Unit 5 Wortley Trading Estate Wortley Moor Lane Leeds West Yorkshire LS12 4HX Tel: 0113 202 2010 Fax: 0113 301 0212 Agrément Certificate e-mail: info@specialisttilingsupplies.com

More information

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION Saint-Gobain Isover UK East Leake Loughborough Leicestershire LE12 6JQ Tel: 0115 9451000 Fax: 0115 9451154 e-mail: isover.enquiries@saint-gobain.com website: www.isover.co.uk APPROVAL INSPECTION TESTING

More information

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100 Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 website: www.jablite.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION

More information

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS Klober Ltd Unit 6F, East Midlands Distribution Centre Short Lane Castle Donington Derbyshire DE74 2HA Tel: 01332 813050 Fax: 01332 814033 e-mail: support@klober.co.uk website: www.klober.co.uk APPROVAL

More information

THERMALITE AIRCRETE BLOCKS AND THIN-JOINT SYSTEM THERMALITE THIN-JOINT SYSTEM

THERMALITE AIRCRETE BLOCKS AND THIN-JOINT SYSTEM THERMALITE THIN-JOINT SYSTEM Forterra Building Products Limited 5 Grange Park Court Roman Way Northampton NN4 5EA Tel: 0330 123 1018 Fax: 01530 273183 e-mail: asktechnical@forterra.co.uk website: www.forterra.co.uk APPROVAL INSPECTION

More information

H + H AIRCRETE BLOCKS AND THIN-JOINT SYSTEM H + H THIN-JOINT SYSTEM

H + H AIRCRETE BLOCKS AND THIN-JOINT SYSTEM H + H THIN-JOINT SYSTEM H + H UK Ltd Celcon House Ightham Sevenoaks Kent TN15 9HZ Tel: 01732 886333 Fax: 01732 886810 e-mail: marketing@hhcelcon.co.uk website: www.hhcelcon.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

SPRINGVALE FLOORING INSULATION FOR CONCRETE GROUND FLOORS

SPRINGVALE FLOORING INSULATION FOR CONCRETE GROUND FLOORS Springvale EPS Ltd Dinting Vale Business Park Dinting Vale Glossop Derbyshire SK13 6LG Tel: 01457 863211 Fax: 01457 869269 e-mail: sales@springvale.com website: www.springvale.com APPROVAL INSPECTION TESTING

More information

BAUDER PIR INSULATION BAUDER PIR ROOF INSULATION BOARDS

BAUDER PIR INSULATION BAUDER PIR ROOF INSULATION BOARDS Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 0DH Tel: 01473 257671 Fax: 01473 230761 e-mail: info@bauder.co.uk website: www.bauder.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Agrément Certificate 13/5069 website: Product Sheet 1

Agrément Certificate   13/5069 website:  Product Sheet 1 British Polythene Limited t/a Visqueen Building Products Heanor Gate Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 Page 1 of 9 Agrément Certificate e-mail: enquiries@visqueenbuilding.co.uk

More information

SIKA ADHESIVE SYSTEM

SIKA ADHESIVE SYSTEM Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper Domestic and General Insulation Ltd Energy House Magnis Works Roman Road Hereford HR4 9QR Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION

More information

Agrément Certificate 08/4551 website: Product Sheet 1

Agrément Certificate   08/4551 website:  Product Sheet 1 Alucoil SA Pol Ind Bayas C/Ircio, parc R72-R77 09200 Miranda de Ebro (Burgos) Spain Tel: 00 34 947 33 33 20 Fax: 00 34 947 33 12 24 Page 1 of 10 Agrément Certificate e-mail: info@alucoil.com 08/4551 website:

More information

Agrément Certificate 17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS

Agrément Certificate   17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS Ultra Liquid Polymers Ltd 39 Everton Road Birkdale Merseyside PR8 4BT Tel: +44 (0) 3304 004457 Fax: +44 (0) 3304 004458 Agrément Certificate e-mail: info@ultra-polymers.com 17/5420 Product Sheet 1 ULTRA

More information

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER CI/SfB Lh4 (M2) Web Dynamics Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: thinsulex@webdynamics.co.uk website: www.webdynamics.co.uk Agrément Certificate

More information

PUDLO CWP (CEMENT WATERPROOFING POWDER)

PUDLO CWP (CEMENT WATERPROOFING POWDER) David Ball Group plc Huntingdon Road Bar Hill Cambridge CB3 8HN Tel: 01954 780687 Fax: 01954 782912 e-mail: sales@pudlo.com website: www.davidballgroup.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

PERMAROOF 500 LIQUID ROOF SYSTEM

PERMAROOF 500 LIQUID ROOF SYSTEM Permaroof UK Ltd Unit 1, Westway Cotes Park Industrial Estate Alfreton Derbyshire DE55 4QJ Tel: 0800 161 3722 Fax: 01773 608 408 Agrément Certificate e-mail: sales@permaroof.co.uk 16/5372 website: www.permaroof.co.uk

More information

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS Kingspan Insulation Ltd Torvale Industrial Estate Pembridge, Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES PURUS AB Södra Dragongatan 15 SE-271 39 Ystad Sweden Tel: +46 10 41 44 900 Fax: +46 10 41 44 996 e-mail: info@purus.se web: www.purus.se/en-gb APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

NOVABRIK MORTARLESS BRICK SYSTEM Parement extérieur Verkleidung Bedachung. Regulations

NOVABRIK MORTARLESS BRICK SYSTEM Parement extérieur Verkleidung Bedachung. Regulations CI/SfB Acheson & Glover 64 Old Moy Road Dungannon Co Tyrone BT71 6PU Tel: 028 8778 4208 Fax: 028 8778 4805 e-mail: novabriksales@acheson-glover.com website: www.acheson-glover.com/www.novabrik.com (21.9)

More information

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden Designated by Government to issue European Technical Approvals Product Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info.uk@insulation.kingspan.com

More information

KINGSPAN THERMAROOF TR21

KINGSPAN THERMAROOF TR21 CI/SfB Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com (47) Rn Agrément

More information

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke-on-Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF Xypex (UK) LLP Unit 7 Britannia Business Centre Britannia Way Malvern Worcestershire WR14 1GZ Tel: 01684 577756 Fax: 01684 897750 e-mail: adamtrow@xypexuk.com website: www.xypex.com APPROVAL INSPECTION

More information

Agrément Certificate 07/4420 website: Product Sheet 2

Agrément Certificate    07/4420 website:  Product Sheet 2 Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 Agrément Certificate e-mail: sales@vapfree.co.uk; danny@vaprfree.co.uk 07/4420

More information

JABLITE EPS BLOCKS JABLITE QUICKFLOOR EPS INFILL BLOCKS

JABLITE EPS BLOCKS JABLITE QUICKFLOOR EPS INFILL BLOCKS Jablite Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9 Fax: 020 8320 9110 e-mail: sales@jablite.co.uk website: www.jablite.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE Visqueen Building Products Heanor Gate Heanor Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 e-mail: enquiries@visqueenbuilding.co.uk website: www.visqueenbuilding.co.uk APPROVAL INSPECTION

More information

MAX FRANK EGCOBOX CANTILEVER CONNECTION SYSTEM EGCOBOX CANTILEVER CONNECTION SYSTEM

MAX FRANK EGCOBOX CANTILEVER CONNECTION SYSTEM EGCOBOX CANTILEVER CONNECTION SYSTEM Max Frank Ltd Whittle Road Meir Stoke on Trent Staffordshire ST3 7HF Tel: 01782 598041 email: info@maxfrank.co.uk website: www.maxfrank.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924 HAPAS Roads and Bridges Trustseal Ltd Unit 10 Southfield Industrial Estate Southfield Lane Whitwell, Worksop Nottinghamshire S80 4NW Tel: 01909 722662 Fax: 01909 720228 e-mail: info@trustseal.co.uk website:

More information

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES General Membrane SpA Via Venezia 28 30022 Ceggia (VE) Italy Tel: 00 39 0421 322000 Fax: 00 39 0421 322800 e-mail: info@generalmembrane.it website: generalmembrane.it APPROVAL INSPECTION TESTING CERTIFICATION

More information

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS) CI/SfB Yu2 Kryton International Inc 1645 East Kent Avenue Vancouver British Columbia Canada V5P 2S8 Tel: 00 1 604 324 8280 Fax: 00 1 604 324 8899 e-mail: info@kryton.com website: www.kryton.com Agrément

More information

EUROBRICK CLADDING SYSTEMS P-CLAD EXTERNAL CLADDING SYSTEM

EUROBRICK CLADDING SYSTEMS P-CLAD EXTERNAL CLADDING SYSTEM Eurobrick Building Systems Ltd Unit 7 Wilverley Trading Estate Bath Road Brislington Bristol BS4 5NL Tel: +44 (0)117 971 7117 Fax: +44 (0)117 971 7217 e-mail: info@eurobrick.co.uk website: www.eurobrick.co.uk

More information

MONOCOUCHE RENDERS WEBER.PRAL M

MONOCOUCHE RENDERS WEBER.PRAL M Saint-Gobain Construction Products UK Ltd t/a Saint-Gobain Weber Dickens House Enterprise Way Maulden Road Flitwick Bedfordshire MK45 5BY Tel: 0870 333 0070 Fax: 0800 014 2995 e-mail: mail@netweber.co.uk

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper Norbord Ltd Station Road Cowie Stirling FK7 7BQ Tel: 01786 812921 Fax: 01786 817143 e-mail: info@norbord.net website: www.norbord.net APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION

More information

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS Sika Ltd Watchmead Welwyn Garden City Herts AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: waterproofing@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

BDA Agrément BAW /01/C

BDA Agrément BAW /01/C Number BAW 15-046//C Replaces: - Date 25.09.04 Project number 14-B-0308/2 Product Producer (Certificate holder) BDA Agrément BAW 15-046//C Document linked with Kiwa Certificate KGaC 2006 GB, issued by

More information

JABLITE FLAT ROOF INSULATION ROOF BOARDS JABLITE INVERTED ROOF INSULATION HIGH PERFORMANCE (HP)

JABLITE FLAT ROOF INSULATION ROOF BOARDS JABLITE INVERTED ROOF INSULATION HIGH PERFORMANCE (HP) APPROVAL INSPECTION TESTING CERTIFICATION Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM Sika Liquid Plastics Sika House Miller Street Preston Lancashire PR1 1EA Tel: 01772 259781 Fax: 01772 255670 e-mail: liquidplastics@uk.sika.com website: www.liquidplastics.co.uk APPROVAL INSPECTION TESTING

More information

RESITRIX ROOF WATERPROOFING SYSTEMS

RESITRIX ROOF WATERPROOFING SYSTEMS Carlisle Construction Materials GmbH Schellerdamm 18 D-21079 Hamburg Germany Tel: 00 49 40 788 933 200 Fax: 00 49 40 788 933 201 e-mail: info@ccm-europe.com website: www.ccm-europe.com APPROVAL INSPECTION

More information

Agrément Certificate 16/5333 website: Product Sheet 1

Agrément Certificate   16/5333 website:  Product Sheet 1 Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 (Marketing) 0161 865 8433 (Technical) Agrément Certificate e-mail: info.uk@icopal.com 16/5333 website:

More information

DELTA MEMBRANE SYSTEMS DELTA-PT

DELTA MEMBRANE SYSTEMS DELTA-PT Delta Membrane Systems Ltd Unit 7 Bassett Business Centre Hurricane Way North Weald, Epping Essex CM16 6AA Tel: 01992 523811 Fax: 01992 524046 e-mail: info@deltamembranes.com website: www.deltamembranes.com

More information

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM Phoenix Dichtungstechnik GmbH Eisenacher Landstrasse 70 D-99880 Walterhaussen Germany Tel: 00 49 40 7667 2807 Fax: 00 49 40 7667 2949 website: www.pdt-waterproofing.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

COLORCOAT PANELS COLORCOAT URBAN WALL PANEL

COLORCOAT PANELS COLORCOAT URBAN WALL PANEL Tata Steel UK Limited Shotton Works Deeside Flintshire CH5 2NH Tel: 01244 892459 (Technical enquiries: 01244 892446) Fax: 01244 892442 e-mail: colorcoaturban@tatasteel.com website: www.colorcoaturban.com

More information

ALUPANEL XT WORKING PRACTISE. For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding.

ALUPANEL XT WORKING PRACTISE. For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding. ALUPANEL XT WORKING PRACTISE For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding. Before we are able to supply a quotation for the supply of this material, we require

More information

DELTA MEMBRANE SYSTEMS DELTA-MS500

DELTA MEMBRANE SYSTEMS DELTA-MS500 Delta Membrane Systems Ltd Delta House Merlin Way North Weald, Epping Essex CM16 6HR Tel: 01992 523523 Fax: 01992 523250 e-mail: info@deltamembranes.com website: www.deltamembranes.com APPROVAL INSPECTION

More information

Certificate of Assessment

Certificate of Assessment Certificate of Assessment Certificate Number: 159/13 Revision: 03 Kemsley Fields Business Park Sittingbourne Kent ME9 8SR is authorised to use the BRE Global Certification Mark in association with the

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

CEMBRIT SLATES ZEELAND SLATES

CEMBRIT SLATES ZEELAND SLATES Cembrit a.s. Lidická 302 266 38 Beroun 3 Czech Republic Tel: 00 420 311 744111 Fax: 00 420 311 744248 e-mail: info@cembrit.cz website: www.cembrit.cz APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

POLARWALL FORMWORK SYSTEMS POLARWALL INSULATING CONCRETE FORMWORK SYSTEM

POLARWALL FORMWORK SYSTEMS POLARWALL INSULATING CONCRETE FORMWORK SYSTEM Polarwall Ltd 5 Exe Units Cofton Road Marsh Barton Exeter EX2 8QW Tel: 0845 8382181 e-mail: info@polarwall.co.uk website: www.polarwall.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES Danosa (Derivados Normalizados Asfálticos S.A) Polígono Industrial Sector 9 19290 Fontanar Guadalajara Spain Tel: 00 34 94 98 88 210 Fax: 00 34 94 98 88 223 e-mail: info@danosa.com website: www.danosa.com

More information

BECO CONCRETE FORMWORK SYSTEMS BECO WALLFORM INSULATING CONCRETE FORMWORK SYSTEM

BECO CONCRETE FORMWORK SYSTEMS BECO WALLFORM INSULATING CONCRETE FORMWORK SYSTEM Beco Products Ltd 5 Atherton Way Brigg North Lincolnshire DN20 8AR Tel: 01652 653844 e-mail: info@becowallform.co.uk website: www.becowallform.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2600 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 07 00 00 THERMAL

More information

Garage Conversion - Between and Under Joist Applications

Garage Conversion - Between and Under Joist Applications Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,

More information

HP Partial Fill. Robust, long-lasting protection

HP Partial Fill. Robust, long-lasting protection 1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly

More information

BRE Global Assessment Report

BRE Global Assessment Report BRE Global Assessment Report An assessment of the fire performance of the Gebrik Insulating Brick Cladding System against BR 135, Third Edition Prepared for: Date: 13 April 2016 Aquarian Cladding Systems

More information