VPA 8 Status: October 2014 Test Certificates. Containers made of plastic with bung hole or removable lid 4. Fibre drums 5
|
|
- Aubrey Bishop
- 6 years ago
- Views:
Transcription
1 VPA 8 Status: October 2014 s Survey: page s for: Sheet steel containers with bung hole with / without PE inner receptacle 2 Sheet steel containers with removable lid with/without PE inner receptacle 3 Containers made of plastic with bung hole or removable lid 4 Fibre drums 5 Cans and canisters made of plastic 6 Cans and canisters made of metal 7 Bottles made of plastic 8 Bottles made of aluminium 9 Flexible IBC 10 Cardboard IBC 11 Metal IBC, rigid plastic IBC, composite IBC 12 made of corrugated cardboard 13 Bags and sacks 14 Shrink and stretch wrap 15 Boxes made of wood / wooden materials 16 Pallets from wood 17 Foam moulded parts 18 Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 1
2 s No.: Sheet steel containers with bung hole with / without PE inner receptacle - Customer/ Lot-/Serial-No: Nominal sheet thickness: Material / Open-head drum: Material / Inliner: No.: Nominal Capacity: Total Height Outer Diameter Total mass (kg) Mass-Inliner (kg) Brimful Capacity (l) Pneumatic Leagage Test Visual inspection General cleanliness, seams, folds, closures, coatings inside/outside, no corrosion and no condensate inside, UN-Marking Type according to technical spedification dates... / / Sheet steel containers with bung hole with / without PE inner receptacle Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 2
3 s No.: Sheet steel containers with removable lid with / without PE inner receptacle - Customer/ Lot-/Serial-No: Nominal sheet thickness: Material / Open-head drum: Material / Inliner: No.: Nominal Capacity: Total Height Outer Diameter over the tension ring Total mass (kg) Mass-Inliner (kg) Brimful Capacity (l) Pneumatic Leagage Test Visual inspection General cleanliness, seams, folds, closures, coatings inside/outside, no corrosion and no condensate inside, lid, closing ring, UN-Marking Type according to technical spedification dates... / / Sheet steel containers with removable lid with / without PE inner receptacle Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 3
4 s No.: Containers made of plastic with bung hole or removable lid - Customer/ Lot-/Serial-No: Material: Barrier Material: No.: Nominal Capacity: Total Height Outer Diameter Mass with / without closure Brimful Capacity Pneumatic Leagage Test Barier Material (kg) Visual inspection General cleanliness, no extrusion blow molding failer, closures, closing ring, lid, seal capability, colouring, UN-Marking (l) Type according to technical spedification dates... / / Containers made of plastic with bung hole or removable lid Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 4
5 No.: Fibre Drums Lot- / Serial-No.: Material / Inliner: -No.: Total Height to top edge lid Sheet thickness body Outer Diameter Number of plies Total mass (kg) Sheet thickness / bottom Nominal Capacity (l) Sheet thickness / lid Leak tightness Inliner Visual inspection General cleanliness, closure, gasket, coatings, glueing, corrosion, printing, lid, closing ring, UN-Marking Type according to technical specification dated... / / Fibre drums Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 5
6 s No.: Cans and canisters made of plastic - Customer/ Lot-/Serial-No: Material: Barrier Material: No.: Nominal Capacity: Total Height Total Width Total Length Outer Diameter Mass with / without closure Brimful Capacity Pneumatic Leagage Test Barrier Material (g) Visual inspection General cleanliness, no extrusion blow molding failer, closures, seal capability, UN-Marking, colouring (l) Type according to technical spedification dates... / / Cans and canisters made of plastic Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 6
7 No.: Cans and canisters made of metal Lot- / Serial-No.: UN- resp. RID/ADR-Marking: Material: -No.: Nominal Capacity: Total Height Brimful Capacity (l) Total Length Total Width Mass with / without closure (g) Outer Diameter Sheet thickness bottom Tin coating (g/m³) Sheet thickness top Sheet thickness body Lid opening air flow pressure. kpa Pneumatic Leakage Test Visual inspection General cleanliness, seams, folds, closures, gaskets, printing, coatings inside/outside, no corrosion and no condensate inside, UN resp. RID/ADR- Marking Type according to technical specification dated... / / Cans and canisters made of metal Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 7
8 s No.: Bottles made of plastic - Customer/ Lot-/Serial-No: Material: No.: Nominal Capacity: Total Height Total Width Total Length Outer Diameter Wall thickness Weight (g) Pneumatic Leagage Test Visual inspection General cleanliness, no particle inclusions, thin places, deformation, pinch-off welds and flashes, surface condition, colouring, UN-Marking Type according to technical spedification dates... / / Bottles made of plastic Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 8
9 No.: Bottles made of aluminium Lot- / Serial-No.: Material: -No.: Nominal Capacity: Wall thickness bottom Total mass Wall thickness top edges Brimful Capacity (l) Thickness body Total Height Outer Diameter Pneumatic Leakage Test Visual inspection General cleanliness, no die marks or wrinkles, indentions, swaf, plastic packing ring, thread, UN-Marking Type according to technical specification dated... / / Bottles made of aluminium Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 9
10 No.: Lot- / Serial-No.: Flexible IBC No.: Nominal Capacity: Dimensions Target Actual Dimensions Target Actual Overall Length Filling shute-lenght Overall Width Filling shute-ø Overall Height Discharge shute-lenght Coating Discharge shute-ø Film Thickness Inliner Apron Length Inliner L x B x H / d x h Type of fabric/ Grammage Body Top (g / m 2 ) Apron Bottom Filling shute Discharge shute Dimenions Inliner Length ( mm ) Material Inliner: Nominal working load (SWL): Width ( mm )...kg Safety Factor (SF):... Antistatic finish: UV-stabiliser: Visuat inspection General cleanliness, no fabric defects, closures, UN-Marking, printing, inliner, belts, seams Type according to technical specification dated... / / Flexible IBC Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 10
11 No.: Cardboard IBC Lot- / Serial No.: No.: Nominal Capacity: Internal Dimensions Length Width Height Thickness Target Actual Target Actual Target Actual Target Actual Composition Paper grade Grammage (g/m 2 ) Outer cover Corrugation Intermediate cover Corrugation Inner cover Target Actual Burst resistance DIN EN ISO 2759 (Pa ) Top to bottom compression resistance DIN EN ISO (N) Puncturing energy DIN Edge crush resistance DIN EN ISO 3037 Water absorption DIN EN ISO 535 Stability of longitudinal edge Wet strengt hof the glue bond Visual Inspection General cleanliness, top flaps, manufacturer s joint, creasing, printing, UN-Marking (J) (kn/m) (g/m²) (N/100 mm) Type according to technical specification dated... / / Cardbord IBC Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 11
12 No.: Metal IBC, rigid plastic IBC, composite IBC Lot- / Serial-No.: Material / Outer Receptacle: Material / Inliner: -No.: Nomal Capacity: Overall Length Total mass (kg) Overall Width Mass Inliner (kg) Overall Height Wall thickness Brimful Capacity (l) Pneumatic Leakage Test Pallet / Timber quality: Visual Inspection General cleanliness, fastenings, seams, no condensate inside, closures, fittings, UN-Marking Clompliant to BAM-GGR 001 (German Dangerous Goodes Rules) Type according to technical specification dated... / / Metal IBC, rigid plastic IBC, composite IBC Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 12
13 No.: made of corrugated cardboard Lot- / Serial-No.: No.: Internal Dimensions Length Width Height Thickness Target Actual Target Actual Target Actual Target Actual Composition Paper grade Grammage (g/m 2 ) Target Actual Outer cover Corrugation Intermediate cover Corrugation Inner cover Burst resistance DIN EN ISO 2759 (Pa ) Top to bottom compression resistance DIN EN ISO (N) Puncturing energy DIN Edge crush resistance DIN EN ISO 3037 Water absorption DIN EN ISO 535 Wet strengt hof the glue bond DIN Visual Inspection General cleanliness, manufacturer s joint, top flaps, creasing, printing, UN-Marking (J) (kn/m) (g/m²) Type according to technical specification dated... / / made of corrugated cardboard Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 13
14 No.: Bags and Sacks Lot- / Serial-No.: -No.: Requirements Material Grammage (g/m 2 ) Film thickness (µm) Target Actual Target Actual Ply 1 Outside ply Ply 2 Ply 3 Ply 4 Ply 5 Ply 6 Ply 7 Dimensions Target Actual Dimensions Target Actual Width Valve width Length Valve lenght Bottom width Gusset dimension Weight (g) Width Welding seam stability Leak thightness Antistatic finish UV-protected Visual Inspection General cleanliness, seams, needling, valve open recess, valve design, colouring, printing, UN-Marking PE-Inliner Target Actual Length Type according to technical specification dated... / / Bags and Sacks Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 14
15 Test Certification-No.: Test Certification Shrink and stretch Wrap Lot- / Serial-No.: Material: No.: Total Width Total Length Gusset Film thickness (µm) Grammage (g/m 2 ) Reel diameter Core diameter Shrink values / longitudinal (%) Shrink values / transverse (%) Colouring Printing Marking Antistatic finish UV-Stabilisation Visual Inspection General cleanliness, border marking, welds Type according to technical specification dated... / / Shrink and stretch wrap Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 15
16 -No.: Boxes made of wood / wooden materials Material: No.: External dimensions Target Actual Total Height Total Width Total Length Board thickness Fasteners Visual Inspection General cleanliness, surface condition, no spits, knot holes, splinters and overlapping fasteners, clear printing, UN-Marking Type According to technical specification dated... / / Boxes made of wood / wooden materials Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 16
17 -No.: Pallets from wood Lot- / Serical-No.: Marking: -No.: Dimensions Length Width Height/Thickness Deck boards Deck boards Stringer boards Bottom boards Bottom boards Blocks Target Actual Target Actual Target Actual Materials / Woods Target Actual Deck boards Stringer boards Bottom boards Blocks Visual Inspection General cleanliness, square edged, no knot holes, spits, tree bark, splinters and midlewed wood; fasteners, printing Type according to technical specification dated... / / Pallets from wood Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 17
18 Manufactuer: -No.: Foam moulded parts Lot- / Serial-No.: Material: -No.: Total overall length Total overall width Total overall height Special dimensions 1 Special dimensions 2 Moisture (%) Volume weight (g/l) Completed weight (g) Welding / Fracture behaviour Visual Inspection General cleanliness, no particle inclusions, defective foam, spits and formation of cracks and crack elements, no deformation and flashes, defect in colour, surface condition, UN-Marking Type according to technical specification dated... / / Foam moulded parts Standard recommandation obligation; Issued by: Verband der Chemischen Industrie e.v. 18
GUIDELINES FOR THE PACKAGING AND STORAGE OF PESTICIDES FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS
GUIDELINES FOR THE PACKAGING AND STORAGE OF PESTICIDES FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS - ii - GUIDELINES FOR THE PACKAGING AND STORAGE OF PESTICIDES FOOD AND AGRICULTURE ORGANIZATION
More informationChapter 9 Quality assurance Section 9.0 General information
Section 9.0 General information 9.0.0 Contents 9.0 General information 9.0.0 Contents 9.0.1 Introduction 9.0.2 Quality philosophy 9.0.3 Cleanliness of packaging 9.1 Packaging specification 9.1.0 Introduction
More informationDOSSIER: IBC s for the transport of dangerous goods
SEPTEMBER 2016 DOSSIER: IBC s for the transport of dangerous goods IBC s or Intermediate Bulk Containers are containers intended to be used for the transport of bulk products (for example ores, grains,
More informationCustomer Packaging Guidelines
Customer Packaging Guidelines Customer Packaging Guidelines 05.02.16 v1 CONTENTS Introduction Packaging Tips: Parcels Envelopes Packaging Tips: Pallets Crates Drums Pipes Spools & Reels Packaging Tips:
More informationChapter 11 Use and handling of packaging Section 11.0 General information
Section 11.0 General information 11.0.0 Contents 11.0 General information 11.0.0 Contents 11.0.1 Introduction 11.1 Packaging material for areas with explosive atmospheres 11.1.1 Antistatic, dissipative
More informationPART 6 Requirements for the construction and testing of packagings, intermediate bulk containers (IBCs), large packagings, tanks and bulk containers
PART 6 Requirements for the construction and testing of packagings, intermediate bulk containers (IBCs), large packagings, tanks and bulk containers - 275 - CHAPTER 6.1 REQUIREMENTS FOR THE CONSTRUCTION
More informationPART 4 PACKING AND TANK PROVISIONS
PART 4 PACKING AND TANK PROVISIONS - 3 - CHAPTER 4.1 USE OF PACKAGINGS, INCLUDING INTERMEDIATE BULK CONTAINERS (IBCs) AND LARGE PACKAGINGS 4.1.1 General provisions for the packing of dangerous goods in
More information1. General regulations
Page 1 von 1 1. General regulations 1.1 Parts shall be packaged by item. 1.2 The parts will be welded and powder-coated or galvanised at a later stage. The surfaces shall therefore be dry and free of paint,
More informationRAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION
RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION PROVISIONAL BILL OF QUANTITIES RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION 1 RAISED ACCESS FLOOR SPECIFICATION SYSTEM DESCRIPTION This specification
More informationAPC cork sustainable living from the ground up
References This specification applies to all APC CORK references of floating floor panels with a cork surface layer, from the collection with the trade name Assortment, Olympian, Gem, Plank. Definition
More informationCORRUGATED HDPE PIPES FOR SEWER AND STORMWATER
50 corrugated pipes CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER TECHNICAL SPECIFICATIONS SANS 21138-3 ISO 9001/2008 The pipe is black outside and blue on the inside Supplied in lengths of 6 meters.
More informationEngineering Branch Assets Delivery Group
F.1 SCOPE This Technical Specification shall apply to Fibre Reinforced Plastics or Glass Reinforced Plastics (hereinafter referred to as FRP or GRP) structures and the materials used in their manufacture,
More informationRequirements for the construction and testing of packagings for class 6.2 infectious substances of category A
Chapter 6.3 6.3.1 General Requirements for the construction and testing of packagings for class 6. infectious substances of category A NOTE: The requirements of this Chapter don't apply to packagings used
More informationPackaging Form Comparison:
Reinhold Herbert Dipl.Ing.* consulting+ development 61276 Weilrod / Germany www.herbert-consulting.de reinhold.herbert@web.de Packaging Form Comparison: bottelpack bottle versus Non-PVC-bags An integrated
More informationInsulating systems used in agricultural and industrial buildings
Insulating systems used in agricultural and industrial buildings INTRODUCTION Since years, RECTICEL is a leading manufacturer of systems for internal insulation. The EUROTHANE product range has been especially
More informationStandardized expendable packaging for sea container applications
VDA Standardized expendable packaging for sea container applications 4525 This VDA Guide pursues the following objectives: As an intermediate step on the way to achieving overarching global Container Management
More informationNOWPak Bottle System. Liner-based bottle system with a pre-cleaned, two-ply, heat-sealed PTFE T420 liner APPLICATIONS FEATURES & BENEFITS
ADVANED MATERIALS HANDLING NOWPak ottle System Liner-based bottle system with a pre-cleaned, two-ply, heat-sealed PTFE T420 liner The NOWPak Liner-based ottle System is a leading containment and dispense
More informationInsulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved
Insulated Panels 02 2010 Insulated Roof Systems Kingspan X-dek KS1000 XD Longspan Roofpanel Insurer Approved Systems X dek TM Frame-to-Frame Long Spanning Insulated Roof Deck X dek TM is an insulated roof
More informationQuality Standard for ACR Copper Tubes in LWC
Quality Standard for ACR Copper Tubes in LWC Foreword cuproclima is a protected tradename for high-quality seamless copper tubes in levelwound coils (LWC) supplied to manufacturers of heat exchangers for
More informationPTFE BELLOWS POLY FLUORO LTD. POLY FLUORO LTD.260A. Bommasandra Industrial Area, Hosur Road, Bangalore TECHNICAL SPECIFICATION
PTFE BELLOWS TECHNICAL SPECIFICATION 1. MATERIALS 1.1 PTFE Only virgin (not reprocessed) PTFE conforming to ASTM D 1457, type III, IV or V shall be used for the production of bellows; the PTFE raw material
More informationR-Group Finland Oy. RTA, RWTL and RWTS Lifting anchors Design instructions
R-Group Finland Oy RTA, RWTL and RWTS Lifting anchors Design instructions According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved 28.12.2016 2 Table of contents 1 DESCRIPTION
More informationBRUSHES WITH SHANK 62 63
6 6 Wheel Brushes with Shank Knot Wheel Brushes with Shank Ø 6 mm D A H Z R RPM Pack. STH 0.5 0.0 STH 0.50 0.00 ROH 0.50 0.00 mm inch mm inch mm inch max. Art.-No. Art.-No. Art.-No. 75 9 /8 5 5/8 8 5,000
More informationFabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8
Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS1000 DLTR PLUS 1.3 & 0.8 Applications Designed to be an integral part of the Trapezoidal Roof panel system, Kingspan Day-Lite is a range of
More informationGHSP Supplier Packaging Requirements and Guidelines
Revision History Revision Date Section Description Revised By 10/1/15 ALL Initial Release M. Weisenreder 04/04/2017 2.1 Added Inside carton dimensions for parts that are re-packed at GHSP, Box Style columns
More informationPacking Design for Canned Fruit
Packing Design for Canned Fruit KTH 2009-03-06, Department of Solid Mechanics Design project in SE2127 Packaging Materials, 2009 Frida Schildauer, 820429-1986 Pedro Soler, 841216-A419 Introduction One
More informationPLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION
DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM
More informationConstruction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description
Roofing Product Data Sheet Edition 11.2014 / xtra UK Identification no. 02 09 45 05 100 0 000019 Version no. 03 S-Vap 5000E SA Self-adhesive Vapour Barrier Product Description S-Vap 5000E SA is a multi-layer
More information1.1 Dimensions Timber of up to mm thick (KD) can be heat-treated. The maximum thickness varies depending on the type of timber.
Page: 1 of 6 1 Timber details 1.1 Dimensions Timber of up to 60-65 65 mm thick (KD) can be heat-treated. The maximum thickness varies depending on the type of timber. 1.2 Quality In principle, only timber
More informationXtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)
CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as
More informationTRANSPORT OF DANGEROUS GOODS
Recommendations on the TRANSPORT OF DANGEROUS GOODS Model Regulations Volume II Twentieth revised edition UNITED NATIONS ST/SG/AC.10/1/Rev.20 (Vol.II) Recommendations on the TRANSPORT OF DANGEROUS GOODS
More informationInsulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW
Insulated Roof & Wall Panels Solutions Insulated Wall Panel KS1000 RW Applications The KS1000 RW is a metre wide through-fix trapezoidal profiled insulated wall panel which is ideal for both horizontal
More informationThe perfect PVC Additives
The perfect PVC Additives INNOVATIONS FOR PVC PROCESSING 2 About Us Our focus is on the supply of stabilisers for window profiles, foamed profiles, technical profiles and etruded sheets made from rigid
More informationR-Group Finland Oy. REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved
R-Group Finland Oy REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved 10.2.2017 2 Table of Contents 1 DESCRIPTION OF THE SYSTEM...
More informationDossier: What s the difference between P 650 (ADR) and PI 650 (IATA)?
DECEMBER 2015 Dossier: What s the difference between P 650 (ADR) and PI 650 (IATA)? Packing instruction 650 from both ADR and IATA imposes certain requirements on the packaging used for the transport of
More informationOmega seals Trelleborg Ridderkerk BV
Omega seals Trelleborg Ridderkerk BV Contents 1 Introduction 3 2 Design of an Omega Seal 3 3 Applications 4 3.1 Immersed tunnels 4 3.2 Bored tunnels 5 3.3 Aqueducts, canals, sluices and other applications
More informationreusable food approved sterilisable strong and durable good rupture and tear resistance cutting die cutting welding bonding sterilising recycling
Biplex characteristics economic reusable food approved sterilisable strong and durable good rupture and tear resistance ecological water and moisture resistant good chemical resistance light-weight dust
More informationNOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)
NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS
More informationPackaging Handbook for Suppliers. Guidelines for Packaging of Outsourced Items
Packaging Handbook for Suppliers Guidelines for Packaging of Outsourced Items Status: June 2016 Table of Contents 1 Purpose and Area of Application... 3 2 Packaging Requirements... 4 2.1 General Packaging
More informationNUCLEAR. Nuclear Reactor Pressure Vessel Seals
NUCLEAR Nuclear Reactor Pressure Vessel Seals SEALING CONCEPT Technetics Group is the world s leading manufacturer of Nuclear Reactor Pressure Vessel (RPV) Closure Head Seals. In addition, Technetics Group
More informationInnovative solutions made from aluminium foam for the mechanical engineering sector. Strong lightweight
Strong lightweight www.havel-mf.de Innovative solutions made from aluminium foam for the mechanical engineering sector Sandwiches Panels Foam filled profiles 3D shaped elements Strong lightweight With
More informationInsulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP
Insulated Roof & Wall Panels Insulated Roof Panel KS1000 LP Applications The KS1000 LP is a secret-fix shallow profiled insulated roof panel with raised side joints. This panel is ideal for all applications
More informationSHRINK WRAP SCAFFOLD SHEETING
SHRINK WRAP SCAFFOLD SHEETING environmental containment & protection GOOLE SWING BRIDGE [Humberside] Project: shrink wrap Encapsulation of Goole Swing Bridge Purpose: Protect The Dutch River from gritblasting
More informationTechnical Specification KeyKeg Slimline 10L, 20L and 30L
Technical Specification KeyKeg Slimline 10L, 20L and 30L Index Technical Specification... 3 KeyKeg Transport and Storage Recommendations... 4 Background... 4 Transport Risks... 4 Secondary Fermentation...
More informationSEWER FORCE MAIN HDPE PIPE
SECTION 15150 SEWER FORCE MAIN HDPE PIPE PART 1: GENERAL 1-1 DESCRIPTION: This specification governs the material, pipe, fittings, joining methods and general construction practice for High Density Polyethylene
More informationGHSP Supplier Packaging Requirements and Guidelines
Revision History Revision Date Section Description Revised By 10/1/15 ALL Initial Release M. Weisenreder 04/04/2017 2.1 Added Inside carton dimensions for parts that are re-packed at GHSP, Box Style columns
More informationSarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).
Roofing Roofing Product Data Sheet Edition 06.2013 Version no. DE 01 English Vapour control layer Product Description Uses Characteristics / Advantages Tests is an unsupported vapour control layer based
More informationD Side lap. Side lap screw spacing < 500mm factory-installed seals on side lap. Decoupling tape > 60mm
25 Side lap screw spacing < 500mm 333.3 15 42 Decoupling tape > 60mm 3 factory-installed seals on side lap Side lap D 201.1 SECTION VIEWS Type L Ridge profile Type R Ridge flashing FLOOR PLAN > 200 overlap
More informationProcess Inline Filter, Change-Over
Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW
Insulated Roof & Wall Panels Insulated Roof Panel KS1000 RW Applications The KS1000 RW is a through-fix trapezoidal profiled insulated roof panel which can be used for building applications with roof pitches
More informationFERROPLAST Panels: Underway on all roads. Configurator
FERROPLAST Panels: Underway on all roads Configurator Trailer Services Technology FERROPLAST installed to meet your requirements. This brochure not only presents you with the many advantages of the long-lived
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationInsulated Panel Systems. 1, d0 IND E N 1350
Insulated Panel Systems DING TO OR 1, d0-1 ACC IND E N 1350 1 Project: TransWest nv, Kampveldstraat 45, 8020 Oostkamp, Belgium Use: Logistical platform with a negative temperature Technical Information
More informationSTANDARDIZATION IN GEOTECH SECTOR V.K.PATIL
STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL BOMBAY TEXTILE RESEARCH ASSOCIATION L.B.S.MARG, GHATKOPAR (W),MUMBAI-400086. WEB : btraindia.com e-mail : btra@vsnl.com What are Standards? Standards are published
More informationDiaphragm seal with flange connection With internal diaphragm, threaded design Model
Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,
More informationACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT
ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT Specification for Acoustical Insulation (Lagging) for Piping and Equipment 1 of 5 TABLE OF CONTENTS 1.0SCOPE..... 3 2.0REFERENCED PUBLICATIONS...
More informationInsulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials
1 Superior FIRE Protection 2 Unrivalled THERMAL Efficiency 3 ENHANCED Environmental Credentials 4 Longest Performance GUARANTEE Insulated Panel System QuadCore IND Technical Information Projet / Usage
More informationHelicopter drop testing of Type B packages in UK
Helicopter drop testing of Type B packages in UK R. Vaughan* 1 and L. M. Farrington 2 Testing was carried out in UK in 1986 to demonstrate the ability of two type B packages designed to pass the 9 m drop
More informationSpecifications for Concrete Embedment Liner
Specifications for Concrete Embedment Liner Part 1: GENERAL 1.01 SECTION INCLUDES A. Specifications and guidelines for MANUFACTURING high-density polyethylene embedment liners. 1.02 REFERENCES A. American
More informationPACKAGING STANDARD FOR USED LEAD ACID BATTERIES (ULAB)
PACKAGING STANDARD FOR USED LEAD ACID BATTERIES (ULAB) ProjecT SPONSORED BY: Club Assist www.clubassist.com.au (03) 9797 8600 PACKAGING STANDARD FOR USED LEAD ACID BATTERIES (ULAB) CONTENTS 1. Introduction
More informationFirestone Polyiso Boards
Firestone Polyiso Boards Superior energy efficiency. Superior protection. Firestone Polyiso Boards POLISOBROUK10.indd 1 1/04/10 14:26 Firestone Polyiso Boards Firestone total roofing systems Since Firestone
More informationROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...
PRODUCT CATALOG Energy efficiency for constructions... Always environment-friendly... www.prodexcr.com CONSTRUCTION AREA REFLECTIVE THERMAL INSULATION AD AD= ALUMINUM + ALUMINUM 0,39; 0,19; and 0,11 in
More informationPOLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES
POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES A large percent of corrosion failures on cathodically protected structures are associated
More informationOSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE
OSNALINE Tubes and tube bundles KME Germany AG & Co. KG OSNALINE [GB] Member of the KME Group KME Germany AG & Co. KG Experts in tube bundles KME Germany AG & Co. KG is a member of the KME Group S.p.A.
More informationITEM 458 WATERPROOFING FOR STRUCTURES
ITEM 458 WATERPROOFING FOR STRUCTURES 458.1. Description. This Item shall govern for the furnishing and placing of waterproofing on concrete and steel bridge decks of railroad structures and on other structures
More informationProduct Data Sheet. Product: Benchmark Wall Liner System
APPLICATION The Benchmark Wall Liner system is to be used as an insulated composite wall panel under site applied fully supported or self-supported aluminium, copper, zinc and stainless steel cladding
More informationHeating elements shall not be used for FRP tank-containers including tank swap bodies.
Chapter 6.9 6.9.1 General Requirements for the design, construction, equipment, type approval, testing and marking of fibre-reinforced plastics (FRP) tank-containers including tank swap bodies NOTE: For
More informationE. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.
DELTA -DRAIN Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade drainage sheets. B. Plaza deck and planter drainage sheets. 1.2 RELATED SECTIONS A. Section
More informationVery Thin Medium Density Fibreboards (MDF) with Paperboard-like Properties as Reusable Packaging Material
Very Thin Medium Density Fibreboards (MDF) with Paperboard-like Properties as Reusable Packaging Material Folie 1 Current situation Market data for cardboards for packaging (Germany) growth for period
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationBentoflex is a bentonitic waterproofing composite, specifically designed for use in construction, consisting of an original, patented, flexible
Bentoflex is a bentonitic waterproofing composite, specifically designed for use in construction, consisting of an original, patented, flexible structure and sealed selvages. Bentoflex contains a sodium
More information4G/Y37.5/S/** USA/+CO1382
T-MAK Labs, Inc., 1205 Karl Ct., Suite 108, Wauconda, IL 60084 Phone: 847-469-8630 Fax: 847-469-8918 www.t-maklabs.com Section 1: Basic Information Re: S-7351 (S-7339) Date of Report: November 06, 2015
More informationBENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES
BENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES This specification is intended for use as a GENERAL GUIDELINE for developing a specification for a specific project. It is NOT intended as a
More informationTetra Pak Aseptic Package Integrity. Mike Bolstridge Director Product Quality and Safety IFTPS March 2012
Tetra Pak Aseptic Package Integrity Mike Bolstridge Director Product Quality and Safety IFTPS March 2012 Aseptic Packaging Definition: Hermetically sealed to prevent re-infection Tetra Brik Aseptic 1.
More informationSandwich panel SPA Product description
Sandwich panel SPA Product description Ruukki offers a sandwich panel system that combines an attractive appearance with excellent thermal insulation and fire-resistance. The panels are of a lightweight,
More informationPERFORMANCE SPECIFICATION PACKAGING AND PACKING REQUIREMENTS FOR SPECIAL PURPOSE MECHANICAL COMPONENTS AND REPAIR PARTS
INCH-POUND MIL-PRF-23199F (SH) 30 April 2012 SUPERSEDING MIL-P-23199E (SH) 28 February 1997 PERFORMANCE SPECIFICATION PACKAGING AND PACKING REQUIREMENTS FOR SPECIAL PURPOSE MECHANICAL COMPONENTS AND REPAIR
More informationLuka Quality Assurance Manual (Eng)
Luka Quality Assurance Manual (Eng) Contents: 1 General... 3 1.01 Foreword... 3 2. Quality assurance standards for air ducts... 4 A.1.00 Rectangular galvanised steel ducts... 4 A.2.00 Embedded galvanised
More informationGuidelines for shelf ready packaging Coop Norden. Dry Goods
Guidelines for shelf ready packaging Coop Norden Dry Goods For standard range product presentations on shelves and on pallets as well as campaign presentations of standard range products on pallets or
More informationSHEET METAL ROOF TEST REPORT
SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA
More informationREPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00
More informationOur bags are manufactured from sealable materials and are designed to provide the maximum protection for your products: Gastight Water vapor barrier
Bags Customized packaging bags There s no getting around the fact that the commercial success of your products is largely dependent on their being impeccably packaged. Packaging preserves the product s
More informationPerfect technology with design. Hoesch Sectional door elements
Perfect technology with design Hoesch Sectional door elements hoesch sectional door elements content 2 for more than three decades, thyssenkrupp Bausysteme has been one of the market leaders in cutting-edge
More informationInsulated Roof & Wall Panels Solutions. Product Data Sheet. Topdek Single Ply Insulated Roof Deck KS1000 TD
Insulated Roof & Wall Panels Solutions Single Ply Insulated Roof Deck KS1000 TD Applications The KS1000 TD is a single component, factory pre-engineered roof deck, comprising a high performance single-ply
More informationCold Work Cladding Fabrication & Application
TRADE OF Industrial Insulation PHASE 2 Module 3 Substructures, Advanced Cold Work and Cladding UNIT: 4 Cold Work Cladding Fabrication & Application Produced by In cooperation with subject matter expert:
More informationDIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS
DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationProduct Data Sheet. QuadCore Karrier. Applications
Applications The Quad Karrier system is face fixed, provides the support, thermal and weathering functions to the Benchmark facades. The panel can be laid horizontally or vertically. Suitable for all building
More informationEXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,
More informationK-FLEX K-FONIK INDUSTRIAL
J a n u a r y 2 0 1 3 K-FLEX K-FONIK INDUSTRIAL Sound & Thermal Insulation design compliant with ISO 15665 www.kflexenergy.com Flexible Elastomeric Foam layer INSULATING PIPING WITH K-FLEX SHEETS > FIRST
More informationPSI Anti-Corrosion Tapes
Pipeline Accessories PSI Anti-Corrosion Tapes General Information Technical Data Requirement Specifications Application Instructions Certificates 1 The Systems PSI anti-corrosion tapes have been specially
More informationGLT GIRDER LONGITUDINALLY TENSILETESTED
GLT GIRDER LONGITUDINALLY TENSILETESTED THE INDIVIDUALLY TESTED SAFETY GUARANTOR. 01 AT A GLANCE AREAS OF APPLICATION Construction and industrial buildings Multi-storey residential buildings Single and
More informationZINC. Product Data Sheet
ZINC Benchmark Zinc system is available in two different cassette options in a range of finishes and is installed onto a specifically designed Benchmark. Images above courtesy of VMZinc FAÇADE DATA Materials
More informationHALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE
HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE Translation of the General Certificate of Approval Approval Office: German Institute for Construction Engineering (Deutsches Institut für Bautechnik DIBt) Kolonnenstrasse
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1114 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00
More informationDINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD
Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description:
More informationInsulated Ruggedized Transport Container - Model Number - SC-20
Introduction The purpose of this document is to emphasise the product benefits of the Ruggedized Insulated Transport Container, Model SC-20, manufactured by Dometic S.àr.l. in Hosingen, Luxembourg. Our
More informationColour and Additive Preparations. for Extruded Polyolefin Foams
Colour and Additive Preparations for Extruded Polyolefin Foams COLOUR AND ADDITIVE PREPARATION FOR EXTRUDED POLYOLEFIN FOAMS ADDITIVES for POLYOLEFIN FOAM HP 73940 FR Flame retardant masterbatch for LDPE-films,
More informationElcometer 118/2. Moisture Meter. Operating Instructions
Elcometer 118/2 English Moisture Meter Operating Instructions English The Elcometer 118/2 Moisture Meter has been tested in accordance with EU regulations governing Electro-magnetic compliance and it meets
More informationSikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour
GLUING AND RIVETING Sikaflex 221, black Elastic Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour connecting and overlapping joints, apron panels, trims, floor assemblies
More informationSTAND009 STANDARD FOR OPTIMIZATION OF CONSUMER UNIT, D-PACK. Version 3.0. March 12. th SUPPLY CHAIN GETS MORE EFFICIENT
STANDARD FOR OPTIMIZATION OF CONSUMER UNIT, D-PACK (TRADING UNIT) AND PALLET IN THE NORWEGIAN GROCERY SECTOR Version 3.0 March 12. th. 2015 BY LIVING UP TO AT ALL LEVELS OF PACKAGING SUPPLY CHAIN GETS
More informationSurface Protection Systems
Surface Protection Systems Industrial Corrosion Protection Applications Technology Bekaplast Bolted Lining 8408SKCe2c.indd 2 11.04.2012 17:13:54 Description of the System Bekaplast Bolted Lining is a thermoplastic
More information