1 NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 NOTE: SECURE COVER PLATE USING TWO FASTENERS WITH NEOPRENE GASKETS AT THE CENTER OF EACH FASCIA SECTION Light-Metal Roof Edge, Raised 5-1
2 NAILS 3 O.C. STAGGERED 2 ROWS METAL SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE SPECIFIED MASTIC 1/2 MIN MAX. JOINT COVER 4 6 WIDE SET IN SPECIFIED MASTIC AND SECURED USING TWO FASTENERS THROUGH THE GAP IN THE FASCIA FLANGE TWO-PLY FELT ENVELOPE CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Roof Edge 5-2
3 NOT TO SCALE PLIES EITHER OVER OR UNDER WOOD CANT AS SPECIFIED ELASTOMERIC SHEET FLASHING AS SPECIFIED. APPLY ADHESIVE FULL WIDTH. WOOD CANT STRIP NAILED TO BLOCKING SPECIFIED APPROX. 1 CANT. MIN. 1 MINIMUM 1,y APPROX. 1 NOT TO SCALE TremLine Fascia Metal Roof Edge 5-3
4 TWO-PLY MECHANICALLY FASTEN, STAGGER 3 O.C. METAL FLANGE SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE. GRAVEL GUARD REQUIRED FOR GRAVEL SURFACED ROOFS GRAVEL ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATE SHEET I-49 FELT ENVELOPE GUTTER BRACKET 36 O.C. DRY SHEET GUTTER SPACER 36 O.C. STAGGERED ALTERNATELY (18 ) WITH BRACKETS SLOPE GUTTER TO DOWNSPOUTS 1/4 IN./FT. MINIMUM Roof Edge with Gutter 5-4
5 SPECIFIED SEALANT COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES 8 O.C. FASTENERS 6 O.C. NAILED VENTED BASE SHEET NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED TWO-PLY BASE FLASHING SPECIFIED, NAILED VENTED BASE SHEET LIGHTWEIGHT INSULATING CONCRETE NOTE: MECHANICALLY ATTACH VENTED BASE SHEET OVER FOIL LAMINATED BARRIER SHEET Base Flashing for Vented Base Sheet 5-5
6 STRUCTURAL SECTION COUNTERFLASHING FASTENED AS NECESSARY WELD PLATE WATERTIGHT 8 MIN. FASTENERS 8 O.C. INSULATE TO PREVENT CONDENSATION TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. I-Beam Flashing 5-6
7 LEAD CAP 1 DOWN INTO PIPE 2 MIN. ROLLED LEAD FLASHING 1 DOWN INTO PIPE SET LEAD FLANGE IN SPECIFIED MASTIC FOR PLUMBING VENTS WITH PERIMETERS LESS THAN 2 : USE LEAD CAPS OPTIONAL: SOLDER STAINLESS STEEL SCREEN PLUMBING VENT STACK MASTIC SEAL AT PERIMETER 4 MIN. TWO-PLY NOTE: 1. SHEET LEAD: MINIMUM 4 LB. PER SQ. FT. 2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR METALS. Plumbing Vent Flashing 5-7
8 METAL SIDING METAL DRIP FLASHING FASTENED 8 O.C. TERMINATION BAR FASTENED 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED 4 MIN. SPECIFIED GRAVEL Metal Wall Flashing 5-8
9 SPECIFIED SEALANT ONE PIECE COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES, 8 O.C. FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING, 2 ROWS STAGGERED EACH ROW 12 O.C. SPECIFIED COMPRESSIBLE TO DECK WITH APPROPRIATE FASTENERS, 2 ROWS STAGGERED Wall Flashing for Non-Wall Supported Deck 5-9
10 SPECIFIED SEALANT FASTENERS 24 O.C. MINIMUM TWO PIECE COUNTERFLASHING INSTALLED INTO RECEIVER; 3 OVERLAP AT JOINTS OPTIONAL: 2 WIDE CLIP OPTIONAL: SEAL TOP OF FLASHING WITH 3 COURSES OF ASPHALT MASTIC AND REINFORCING MESH FASTENERS 6 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SPECIFIED TWO-PLY BASE FLASHING Wall Flashing Wall Supported Deck 5-10
11 COMPRESSIBLE BUTYL GASKET TAPE TO SPAN IRREGULARITIES TERMINATION BAR FASTENED 8 O.C. SPECIFIED SEALANT SURFACE MOUNTED COUNTERFLASHING FASTENED 8 O.C. MINIMUM ELASTOMERIC FLASHING SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED Wall Flashing for Concrete Walls and Parapets 5-11
12 SHEET METAL COVER AS SPECIFIED FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. 2-PLY Wood Curb 5-12
13 16 GA. MIN. FRAME SEALANT TAPE AS SPECIFIED WOOD NAILER 2 O.C. COUNTERFLASHING FASTENED 18 O.C. 8 MIN. FASTENER 8 O.C. TWO-PLY BASE FLASHING ADHERED TWO-PLY ALTERNATE FRAME LOCATION FOR HEAVY UNITS NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Curb for Air Handling Unit 5-13
14 SHEET METAL HOOD CROSS BREAK OR SLOPE FOR DRAINAGE SEAL METAL SCREW INSULATE INSIDE OF METAL WORK IN COLD CLIMATES CLOSURE DETAIL SHEET METAL COLLAR FASTENERS 8 O.C. SLOPE PIPES DOWN AND AWAY FROM HOOD TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME METAL FLANGE BEFORE. Piping through Roof Deck 5-14
15 STRAINER / DOME CLAMPING RING 4# LEAD FLASHING ELASTOMERIC TAPER TO DRAIN TURN 4# LEAD DOWN INTO DRAIN 1 DECK CLAMP Roof Drain 5-15
16 GRAVEL STOP SPECIFIED SEALANT SOLDER OR SEAL SECTION A A B A A B SECTION B B TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SEAL TOP OF FLANGE METAL SLEEVE THROUGH SCUPPER GRAVEL STOP Scupper 5-16
17 METAL PITCH PAN WITH METAL HOOD SPECIFIED DRAWBAND AND SEALANT FILL TO TOP OF PAN WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket 5-17
18 SPECIFIED DRAWBAND AND SEALANT METAL PITCH PAN WITH METAL HOOD FILL 1 FROM TOP WITH NON-SHRINK GROUT, TOP OFF WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER ELASTOMERIC,, SYSTEM FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket with Grout 5-18
19 STORM COLLAR CAULK DRAW BAND WITH SPECIFIED ELASTOMERIC SEALANT SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE TWO-PLY PROJECTION Metal Sleeve and Storm Collar 5-19
20 STRUCTURAL FRAME PIPE COLUMN STRUCTURAL FRAME UMBRELLA ATTACHED WITH DRAWBAND CAULK WITH SPECIFIED ELASTOMERIC SEALANT MASTIC SEAL AT PERIMETER TWO-PLY 4 MINIMUM WELDED ANCHOR PLATE SINGLE LAYER COMPRESSIBLE NAIL FLANGE TO WOOD NAILER, FLANGE SET IN MASTIC OVER, PRIME FLANGE BEFORE Equipment Stand (Pipe) 5-20
21 SET BOLT IN ELASTOMERIC SEALANT. CAULK PERIMETER OF LEG & FASTENER. NEOPRENE PAD LEG 14 MIN. FASTENERS 24 O.C. ONE-PIECE COUNTERFLASHING 8 MIN. FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Equipment or Sign Support 5-21
22 SECTION A A A 10 0 MAX. A BASE SHEET LINER OVER NAILER SEAL SLOPE INWARD NEOPRENE GASKETED FASTENERS 24 O.C. BASE FLASHING AS SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. SPECIFIED 4 MIN. CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Parapet Cap 5-22
23 FLEXIBLE IMPERVIOUS MEMBRANE ADHERED TO VAPOR RETARDER FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. BOTH SIDES CHAMFER EACH SIDE OF WOOD CURB TO DRAIN FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS SEAL 8 MIN. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. REINFORCED ELASTOMERIC FLASHING MEMBRANE INORGANIC COMPRESSIBLE SPECIFIED SLOPE Expansion Joint 5-23
24 SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS MINIMUM AND 18 PLY SHEETS ADHERED IN SPECIFIED ADHESIVE EXISTING DECK * BEFORE NEXT DAY S WORK, REMOVE TEMPORARY TIE-IN AND FILLERS Daily Waterstop / Tie-In 5-24
25 SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS AND 18 PLY SHEETS ADHERED IN SPECIFIED MASTIC EXISTING DECK Permanent Tie-In 5-25
26 A A A COPING CAP FLASHING AND FASCIA VARIATIONS EXPOSED FACE WITHOUT BRAKES A DIMENSIONS GALVANIZED IRON COLD ROLLED COPPER ALUMINUM 3003-H14 UP TO 6 FACE 24 GA. 16 OZ..040 (18 GA.) 6 TO 8 FACE 24 GA. 16 OZ..050 (16 GA.) 8 TO 10 FACE 22 GA. 20 OZ..064 (14 GA.) 10 TO 15 FACE 20 GA. ADD BRAKES TO STIFFEN.080 (12 GA.) Gauge or Thickness Guide (Minimum) 5-26
DATE R2.2 ROOF DETAILS - BUILT UP ROOF DETAILS CURBS. An Company PHONE:
A B C D E F G H I J K L M N O P Q R S T U V 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 9 GENERAL ROOFING NOTES - VILLAGE POLICE STATION ROOF REPLACEMENT PROJECT - 06 PLANS AND DETAILS - MARCH 0TH, 06. CONTRACTOR
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationRoof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)
More informationWICOMICO COUNTY BOARD OF EDUCATION
GLEN AVENUE ELEMENTARY SCHOOL RO REPLACEMENT PROJECT NUMBER: PSC #.00.9 SR CURRENT CODES: 05 INTERNATIONAL BUILDING CODE 05 INTERNATIONAL MECHANICAL CODE NATIONAL STANDARD PLUMBING CODE (MBPS) 05 EDITION
More informationA. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.
SECTION 076200 - FLASHING AND SHEET METAL PART 1 GENERAL 1.1 SECTION INCLUDES: A. Provide all labor, equipment, and materials fabricate and install the following. 1. Edge strip and flashing. 2. Counterflashings
More information2 + 3 A-2.0 A A-2.1 A-2.0 A A '-8" A-2.0 A-2.0 A-2.0 SIM. A-2.0 A-2.0 A-2.0 SIM. A-2.0 SIM.
SCOPE WORK NOTES LOCATION MAP GENERAL NOTES:.. RO SLOPE: / UNITS PER 2. THE ROING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN WATER TIGHTNESS AND ONE HOSPITAL DRIVE, COLUMBIA, MO 22 PROVIDE PROTECTION
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationTremline. Fascia System. Installation Procedures
Tremline Fascia System Installation Procedures 5 TOP CAP MITERED TOP CAPS JOINT PLATE RIGHT-HAND END CAP PREFAB OUTSIDE CORNER 10 FASCIA FASCIA HOLDER 10 FASCIA CLAMPING RING DECK BRACKET SCUPPER PREFAB
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationWATERPROOFING SYSTEMS BLACK PEARL BASE FLASHING OPTION AT PARAPET RT250-05B 04/2016 WATERPROOFING SYSTEMS TYPICAL CURB DETAIL WITH CONCRETE TRAFFIC SURFACE RT250-06 4/2016 RAM-TOUGH 250DM WATERPROOFING
More informationROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.
3 4" ARRISCRAFT VENEER " NOMINAL AIR SPACE 2" RIGID INSULATION 8" CMU REINFORCED CONCRETE SLAB OVER METAL DECK - REFER TO STRUCTURAL DWGS 20 FIRST FLOOR 343' - 5" CONTINUOUS SEALANT TERMINATION BAR STAINLESS
More informationSECTION FLASHING AND SHEET METAL
SECTION 07600 FLASHING AND SHEET METAL ****** **** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: See MDCPS Design Criteria for flashing condition requirements. ****** **** **** *** ** * **
More informationUNIVERSITY OF SOUTH CAROLINA SUMTER SCIENCE BUILDING ROOF REPLACEMENT WMBE PROJECT NUMBER:
DRAWING LEGEND A.P. SITE LOCATIONS SUMMARY WORK RO DRAIN OVERFLOW SCUER ABANDONED PENETRATION. SCOPE WORK INCLUDES REMOVAL THE ENTIRE EXISTING RO ASSEMBLY ON ALL RO AREAS AND REPLACEMENT WITH NEW RO SYSTEM
More informationASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS
NORTH CHILLER TOWER ROOF R-00 COVER SHEET R-0 ROOF PLAN DRAWING INDEX VICINITY MAP SITE MAP ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS 58 ASHLEY AVE. CHARLESTON, SC 90 STATE PROJECT NO. H5-D5
More informationFascia Systems. oofing 7.1
Systems oofing 7.1 TremLock TM A Pre-engineered, Non-Penetrating Metal Edge System oofing TremLock TM Pre-engineered, Non-penetrating Metal Edge System The TremLock is a pre-engineered, non-penetrating
More informationDISVISON 8: DOORS, WINDOWS AND GLASS SECTION 07600: SHEET METAL FLASHING AND TRIM
DISVISON 8: DOORS, WINDOWS AND GLASS SECTION 07600: SHEET METAL FLASHING AND TRIM Allentown, PA - Plant Expansion PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Flashings and counterflashings, gutters
More informationBuncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations
Index of Drawings General G.00 COVER SHEET G.0 KEY PLAN 70 Westport Road G.0 STAGING PLAN ROOF AREAS: A, B, B, D, D, H, H, H, L AND L Architectural A.0 ROOF PLAN: AREA A, B AND B A.0 ROOF PLAN: AREA D,
More informationGENFLEX TPO DETAILS. PIPE FLASHING T-7.01A Pipe Boot Installation - Hot Air Welded 19 T-7.01B Pipe Boot Installation - Peel & Stick 20
GENFLEX TPO DETAILS 07/2010 Detail Detail Name Page WALL TERMINATIONS T-1.01 Termination Bar 1 T-1.02 Wall Termination with Counter-Flashing 1 T-1.03 Common Counter-Flashing & Membrane Securement 2 T-1.04
More informationSheet Metal Flashing and Trim
University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 076200 - Sheet
More informationTuscaloosa Police Station
Tuscaloosa Police Station 3801 Trevor S Phillips Ave Tuscaloosa, AL 35401 Core Cut: Spray Foam Roof- ½ thick +- Single Ply Membrane Tapered EPS Insulation 2-6 Metal Deck PART 1 GENERAL 1.1 SCOPE OF WORK
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationJuly Minimum Fastening Requirements (Fully Adhered)... 5
EPDM POCKET GUIDE Mule Hide Products EPDM Field Installation Guide Mechanically Fastened and Fully Adhered Systems July 2017 Insulation Attachment Page Minimum Fastening Requirements (Fully Adhered)...
More information1. Rough Carpentry for wood nailers, cants, curbs, and blocking and for wood-based, structural-use roof deck and walls: Division 6.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: SECTION 076200 - SHEET METAL FLASHING AND TRIM 1. Provide all labor, equipment, and materials fabricate and install the following: a. Pre-manufactured
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of
More information2017 FRENGER FOOD COURT ROOFING PROJECT
For: Facilities and Services, NMSU Main Campus, New Mexico State University, Las Cruces, NM : 10/18/2017 - SD & DD REVIEW PACKAGE - NOT FOR CONSTRUCTION CONSULTANTS: ARCHITECT: PROJECT SITE: PROJECT LOCATION:
More informationC. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.
ms1505 SECTION 07 60 00 - Page 1 PART 1 GENERAL 1.01 SECTION INCLUDES A. Coping flashing and cleats. B. Counterflashings at roof edge. C. Counterflashings at roof-mounted mechanical equipment, vent stacks,
More informationPre-Fabricated Roof Curbs
TC-1, TC-2, TC-3, TC-5 Table of Contents General Information 4-5 Specifications 6-9 Assembly Instructions 10-16 Pitch Information 17 Submittal 18-21 54 years of excellence... www.thybar.com 3 Insulated
More informationSECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 07 71 00 ROOF SPECIALTIES SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable in the
More informationSECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work
More informationADDENDUM No. 2 Park Hill School District 2019 Roofing Projects January 30, 2019
ADDENDUM No. 2 Park Hill School District 2019 Roofing Projects January 30, 2019 You are instructed to read and note the following described changes, corrections, clarifications, omissions, deletions, additions,
More informationROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL
ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulation, membrane roofing, base flashings roofing membrane accessories joints, and counter flashings.
More informationSECTION 07530CP EPDM MEMBRANE ROOFING
PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL
More informationCoal Tar Application and Design Considerations
Coal Tar Application and Design Considerations 400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com The proper specification of any roof system is extremely
More informationG October 2018
G-14-18 October 2018 The information contained in this supplement serves as a criteria for Specifiers and Authorized Applicators regarding the design and installation of Carlisle Roofing Systems and use
More informationShepard & Associates, LLC
BUILDING CODE ANALYSIS (FORM F) PROJECT: Roof Recover Project at Jack A. Powers Building SUBMITTAL: [ ] SCHEMATIC [ ] DESIGN DEVELOPMENT [ X ] CONSTRUCTION DOCUMENT DATE: /9/08 CODE & EDITION: 05 IBC &
More informationAPPLICATION SAFETY TOOLS REQUIRED
Revised April 2007 Product Technical Bulletin SFM-3.5H-FR BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT SBS AND DISTILLED BITUMEN, REINFORCED WITH HIGH-STRENGTH FIBERGLASS MAT UL CLASS A FIRE-RATED
More informationMETACRYLICS ACRYLIC ROOF TOP PENETRATION ROOF DETAILS
METS TOP PENETRATION DRAWING INDEX: C-01 - COVER PAGE & DRAWING INDEX SHEET A-01 - WALKING PAD A-02 - METAL PARAPET CAP AND BASE FLASHING A-03 - SKYLIGHT A-04 - PLUMBING VENT A-05 - DRAIN A-06 - SCUPPER
More informationRoof Replacement Specifications Section METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT:
METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT: 1.0 ROOF REMOVAL / METAL AND PLYWOOD DECKS: 1.1 No more roof area than can be made into a watertight
More information2018 FRENGER FOOD COURT ROOFING PROJECT
For: Facilities and Services, NMSU Main Campus, New Mexico State University, Las Cruces, NM : 01/XX/2018 - ISSUED FOR RFP #: CONSULTANTS: ARCHITECT: WILLIAMS AVE. FRENGER FOOD CRT. McFIE CIRCLE PROJECT
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationTarco LeakBarrier EasySystem SBS Self-Adhered Modified Bitumen Roofing System
Tarco LeakBarrier EasySystem SBS Self-Adhered Modified Bitumen Roofing System MODIFIED BITUMINOUS ROOFING GUIDE SPECIFICATION Nailable Substrates with Mechanically Fastened Insulation Note: This specification
More informationSECTION ADHERED SINGLE PLY MEMBRANE ROOFING
SECTION 07535 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered EPDM elastic sheet single ply membrane roofing. B. Related Sections: 1. Section 06100 - Carpentry: Wood deck and curbs. 2. Section
More informationG October 2018
G-13-18 VacuSeal TM Vent Secured Roofing Systems October 2018 The information contained in this supplement serves as a criteria for Specifiers and Authorized Applicators regarding the design and installation
More informationRoofing Products International Re-Flex TPO Fully Adhered Installation Specification
Part 1 General 1.01 System Description A. Fully adhered thermoplastic sheet roof membrane system using Re-Flex Seam Tapes or Heat Weld. 1.02 Specification Designations A. See Plates. 1.03 Regulatory Requirements
More informationProduct Technical Bulletin APS-5T
Revised April 2007 Product Technical Bulletin APS-5T BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APS-5T is a torch
More information1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920
SECTION 07620 - FLASHING AND SHEET METAL PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: Provide all flashing and sheet metal not specifically described in other Sections of these Specifications but
More informationWVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION
075000 ROOFING SYSTEMS PART 1 - GENERAL 1.1. Any deviation from the following instructions must be approved during design by WVU Facilities Management Personnel. 1.2. DEFINITIONS A. ASTM American Society
More informationROOFING APPLICATION STANDARD (RAS) No. 111 STANDARD REQUIREMENTS FOR ATTACHMENT OF PERIMETER WOODBLOCKING AND METAL FLASHING
ROOFING APPLICATION STANDARD (RAS) No. 111 STANDARD REQUIREMENTS FOR ATTACHMENT OF PERIMETER WOODBLOCKING AND METAL FLASHING 1. 2. Scope 1.1 This Application Standard provides:1) the minimum criteria for
More informationROOF DETAILS RD-0 CONSTRUCTION DOCUMENTS - AGENCY/ FEBRUARY 13, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.
ROOF DETAILS CONSTRUCTION DOCUMENTS - 350/ GENERAL PENNSYLVANIA CONSTRUCTION HOUSING PHASE FINANCE 1 AGENCY/ FEBRUARY 13, 017 RD-0 TERMINATION BAR AND SEALANT 1" STAINLESS STEEL METAL RIDGE COPING - PROVIDE
More informationROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only
ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only 1. 2. Scope This application standard covers the procedures for installation
More informationROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)
More informationA. Coordinate Roof Assembly roof insulation work with work before and after. See especially:
07620 ROOF ASSEMBLY STEEL BLOCKING AND SHEET METAL ************************************************************************************************************* SPECIFIER: All roof-related items above
More informationSECTION B. Product Data: Provide manufacturer's standard details and installation instructions.
SECTION 07710 MANUFACTURED ROOF SPECIALTIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof drains for new roofing. B. Roof drains for reroofing. C. Roof drains for retrofitting into existing roof drains.
More informationTPO and PVC Roof Flashings and Accessories
TPO and PVC Roof Flashings and Accessories FlashCap - Plumbers Flashings Standard sizes only: 1 1 /2, 2 3 and 4 of 25 minutes Cylindrical Plumbing Boots Available in all standard pipe sizes. Hose clamp
More informationUNIVERSITY OF MISSOURI Division 07 Thermal and Moisture Protection Roofing:
Roofing: 1. Materials used for moisture protection will comply with specifications contained in the appropriate American Society for Testing and Material standards (ASTM). 2. General roof specification
More informationSECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES
SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES A. Mechanically attached system with thermoplastic roofing membrane. B. Insulation, flat and tapered. C. Flashings. D.
More informationUBC Technical Guidelines Section Edition Membrane Roofing Page 1 of 7..1 Section Building Envelope General Requirements
Page 1 of 7 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 07 00 10 Building Envelope General Requirements 1.2 Coordination Requirements.1 Coordinate design with Building Envelope Consultant. 1.3 Description.1
More informationTGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance
1 of 6 5/8/2012 4:19 PM TGIK.R9734 Roofing Systems, Uplift Resistance Page Bottom Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance KELLY CO-2001 INC 325
More informationShepard & Associates, LLC
BUILDING CODE ANALYSIS (FORM F) PROJECT: Roof Recover Project at Jack A. Powers Building SUBMITTAL: [ ] SCHEMATIC [ ] DESIGN DEVELOPMENT [ X ] CONSTRUCTION DOCUMENT DATE: /9/08 CODE & EDITION: 05 IBC &
More informationRevised Jan-15 Sheet Metal Flashing
PART 1 - GENERAL 1.1 SCOPE OF STANDARD A. This standard provides general guidance concerning the specific preferences of Texas State University for Standing Sheet Metal Roofing. B. Texas State University
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationTarco LeakBarrier EasyTorch APP Torch Applied Modified Bitumen Roofing System
Tarco LeakBarrier EasyTorch APP Torch Applied Modified Bitumen Roofing System 1-PLY APP TORCH APPLIED MODIFIED BITUMINOUS ROOFING GUIDE SPECIFICATION 1 Ply of EasyTorch APP Smooth, torched over an approved
More informationThe Alabama Building Commission has adopted the 2006 International Energy Conservation Code as the State Energy Conservation Code
SECTION 07 20 00 THERMAL PROTECTION SCOPE OF WORK This Section includes building wall, floor and ceiling insulation, and roofing. QUALITY ASSURANCE For all new construction projects and renovation projects
More informationProduct Technical Bulletin SPM-4H-250
Revised April 2007 Product Technical Bulletin SPM-4H-250 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT SBS AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC SPM-4H-250
More informationSECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING
Project Name: Jefferson City Jaycees Fairgrounds Main Building Roof Replacement Project Site Address: 1445 Fairgrounds Road, Jefferson City, MO 65109 Project Contact: Randy Weaver Project Contact phone
More informationSECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
SECTION 07 72 00 ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance
UL TGIK.R9734 Roofing Syst. Uplift Resistance * www.2001company.com * 1.800.537.7663 * Page 1 of 6 Page 1 of 6 Page Bottom TGIK.R9734 Roofing Systems, Uplift Resistance Roofing Systems, Uplift Resistance
More informationSHEET METAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
SHEET METAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing
More informationBrava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:
Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationSECTION FLASHING AND SHEET METAL
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 60 00 1. Use section only for NCA projects. 2. Delete or edit text in // // if not applicable to project. Also delete any other paragraph not applicable in the
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION
DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationA. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section
SECTION 15140 SUPPORTS, ANCHORS, AND SEALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification
More informationREROOFING ANALYSIS OF K-12 BUILDING. Unified School District 306 Gypsum, Kansas
REROOFING ANALYSIS OF K-12 BUILDING Unified School District 306 Gypsum, Kansas Reroofing Analysis of K-12 Building Unified School District 306 Gypsum, Kansas September 12, 2017 P1711 Introduction This
More informationSchedule A Development Permit No Issued this 18 day of April, 2018
Schedule A Development Permit No. 001610 Issued this 18 day of April, 2018 N No. Revision/Issue Date MM/DD/YY 1 ISSUED FOR TENDER 10/26/17 LEGEND: WORK AREA VILLAGE STROLL VILLAGE GREEN SOUTH WING 1 0
More informationSECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.
SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International
More informationSECTION FLASHING AND SHEET METAL
SECTION 07 60 00 FLASHING AND SHEET METAL SPEC WRITER NOTES: 1. Delete or edit text in [ ] if not applicable to project. Also delete any other paragraph not applicable in the section and renumber the paragraphs.
More informationInstallation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ
RPM ROOFING Installation Guide Mission Tile Distributed by: BEST MATERIALS LLC, Phoenx AZ 602-272-8128 800-474-7570 www.bestmaterials.com Table of Contents OVERVIEW...1 CAUTION...1 DISCLAIMER...1 PRODUCT
More informationPiping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System
TCC-1 Pipe Penetration System TCC-3 Pipe Penetration System TCC-5 Pipe Penetration System 54 years of excellence... www.thybar.com 82 Table of Contents General Information 84 Specifications 85 Assembly
More information1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500
07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationA. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.
SECTION 13125 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. 1. Eave Height: 13-0
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationDIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING
07 00 00 PART 1 - GENERAL 1.01 DESIGN CRITERIA A. Preferred roofing types include Membrane, Metal, and Composition Shingles. 1. Membrane roofing is preferred for flat roof decks. 2. Use of asphalt-based
More informationROOFING STUDY GUIDE ARCHITECTURAL SHEET METAL
ROOFING STUDY GUIDE ARCHITECTURAL SHEET METAL PRACTICE TEST ONE 1. It is recommended that base fleshings be applied over a cant and be extended up the wall a minimum of. A. 6 inches B. 8 inches C. 10 inches
More informationOREGON ROOF CONSULTING - ROOF INSPECTION FORM
Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical
More informationMEMBRANE ROOFING Christ on the Mountain
SECTION 075000 MEMBRANE ROOFING PART 1 - GENERAL 1.1 SUMMARY A. This Specification Section has been written around Firestone product technology. All other approved manufacturers shall use the same quality
More informationSenergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board
Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an
More informationMaster Guide Specification Page 1
Master Guide Specification Page 1 SPEC NOTE: This guide specification is intended for use when specifying the restoration of an existing built-up asphalt membrane roof. Make any required selections, such
More informationUpdate In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING
Section 07 10 00 ROOFING AND WATERPROOFING Page 07 10 00-1 1. GENERAL REQUIREMENTS A. Indicate applicable American Society for Testing and Materials (ASTM) specification in this section. 01. Fire resistance
More informationSECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationArchitectural Inspection Pitched Roofing
Architectural Inspection Pitched Roofing 0511 Pitched Roofing All components of the roof system including insulation Description of the building system Three types of pitched roofing are found at the Gastineau
More informationProcurement and Contracting Services
Procurement and Contracting Services Request for Bids for Re-Roofing of Four Buildings for Facilities Management ADDENDUM #2 Please mark all Bid submission Envelopes with the following information Sealed
More informationSOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY
SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced
More informationSECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.
McClellan Blakemore Architects New Warehouse Facility for SECTION 07540 THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES A. Adhered system with thermoplastic roofing membrane. B. Insulation,
More informationC. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense.
PART 1: GENERAL 1.01 Scope Of Standard 1.03 Reference Standards 1.04 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for
More information