1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box E. Division Street Springfield, MO fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Rating: Air Infiltration: Water Resistance: Structural Performance: Thermal Break: AW-PG cfm/ft at 6.2 psf No Leakage at psf psf Yes Main Frame Depth: 3 1/4 Glazing Thickness (Maximum): 1 Boyd Manufacturing Company has prepared this guide specification in printed and electronic media, as an aid to specifiers in preparing written construction documents for commercial fixed aluminum windows. For specification assistance on specific product applications, please contact our offices. Boyd Aluminum Manufacturing Company reserves the right to modify these specifications and details at any time. Updates to these guide specifications and details will be posted to our web site and/or in printed matter as they occur. Boyd Aluminum Manufacturing Company makes no expressed or implied warranties regarding content, errors, or omissions in the information presented boydaluminum.com
2 SECTION ALUMINUM WINDOWS PART 1 GENERAL 1.1 RELATED SECTIONS A. Glass and glazing Section B. Sealants and caulking Section SUMMARY A. Section includes: 1. Fixed Architectural Window Grade aluminum windows. 1.3 REFERENCES a. Fixed windows. A. American Architectural Manufacturers Association (AAMA). B. American Society for Testing Materials (ASTM). C. American National Standards Institute (ANSI) 1.4 TEST AND PERFORMANCE REQUIREMENTS A. Provide aluminum window system designed to accommodate expansion and contraction due to normal thermal movement and wind loading per manufacturer s window test reports. Establish basic dimension of units, sight lines, and profiles of members according to the performance requirements. 1. In order to designate quality of materials and workmanship required, these specifications are based upon products from Boyd Aluminum Manufacturing Co., Inc. Springfield, MO (800) Products of other manufacturers equal to or exceeding those specified herein will be considered upon written authorization by the Architect. Information, including window sample (size and configuration per Architect s requirements) must be submitted for consideration a minimum of 10 days before project bid date. B. Test Criteria: Testing shall be performed by an AAMA qualified independent testing agency and be based on the following criteria: 1. Current test reports must be submitted and be AAMA certified to be accepted.
3 C. Performance Requirements: Test reports must show compliance with AAMA/WDMA/CSA 101/I.S.2/A for AW-PG Air-Infiltration: Shall not exceed 0.03 cfm/ft of sash crack per ASTM E283 at a differential static pressure of 6.2 psf. 2. Water Infiltration: No uncontrolled leakage per ASTM E331 at a test pressure of psf for AW-PG Structural Requirements: Maximum permanent deformation of any component shall not exceed 0.4 percent at a test pressure of psf as defined per ASTM E Forced-Entry Resistance: Comply with Performance Level 10 requirements when tested according to ASTM F SUBMITTALS A. General: Submit in accordance with Division 1. B. Product Data: Submit for windows 1. Include information for factory finishes, glass, glazing components, accessories, and other required components. 2. Submit certified test reports from AAMA accredited laboratories verifying all performance requirements specified herein. C. Shop Drawings: Indicate elevations, detailed design, dimensions, member profiles, joint locations, arrangement of units, and member connections. 1. Anchorage system. 2. Interfacing with building constructions. 3. Full-size details of special and typical shapes. 4. Indicate glazing details and sealant requirements. 5. Show finishes indicating compliance with the specifications. 6. Indicate recorded field measurements on final drawings as available. D. Samples: Indicate quality of finish on alloys used, 12 inches long for extrusions and 6 inches square for sheet materials. 1. Where normal texture or color variations are expected, include additional samples illustrating range of variation. E. Samples of Verification: Submit samples of anchors, fasteners, hardware, assembled corner sections, and other materials and components if requested by the architect. 1.6 QUALITY ASSURANCE A. Installer Qualifications: Certified in writing that installer has experience on at least five projects of similar nature in past five years. The installer shall warrant the satisfactory performance of the window installation which includes, but is not limited to, installation accessories (glazing, perimeter sealing), and anchorage as called for by the specifications and approved shop drawings B. Single Source Responsibility: Provide window units manufactured by one manufacturer 1. Glass and glazing for window units are required as work of this section for single source responsibility. Factory glaze units.
4 1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver units pre-glazed with manufacturer s labels intact on interior side of glass. B. Protect glass and glazing to prevent chipping, cracking, and other similar damages. C. Store windows in upright position, off ground. D. Protect finished surfaces to prevent damage. E. Do not use adhesive papers or sprayed coatings which become firmly bonded when exposed to sun. F. Do not leave coating residue on surfaces. G. Protect the window units from lime, mortar, runoff from concrete and copper, careless handling of tools, weld platter, acids, roofing tar, solvents, abrasive cleaners, and other items that could damage the window units. 1.8 WARRANTY A. Warranty: The window manufacturer shall provide a written warranty that window units are free from defective materials or workmanship within a specified period. Failures include the following: 1. Materials defect in manufacture. 2. Faulty operation of sash and hardware. B. Warranty Period: 2-year after delivery of product C. Warranty Period for Glass: 5-years after delivery of product PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Boyd Aluminum Manufacturing Co. Inc., Springfield, MO (800) Series 6200 Fixed Window B. Subject to compliance with Section 1.4 manufacturers offering equal products may be incorporated in the work.
5 2.2 MATERIALS A. Aluminum extrusions shall comply with ASTM B 221 and tolerances shall be in accordance with the Aluminum Association s Drafting Standards for Aluminum Extruded and Tubular Products. Extrusions shall not be less than a nominal.080 inch thick at any location for main frame and glazing stops. Sheet shall comply with ASTM B 209, alloy and temper recommended by manufacturer appropriate for specified finish. B. Fasteners: Provide stainless steel fasteners, corrosion resistant and compatible with aluminum. 1. Reinforcement: When fasteners screw into aluminum less than a nominal.062 inch thick, utilize nuts or washers of design having means to reinforce interior aluminum surfaces and prevent disengagement. 2. Exposed Fasteners: Provide concealed fasteners wherever possible. C. Shims: Non-staining and non-ferrous type. D. Glazing tape: Blend of polyisobutylene and butylpolymer complying with AAMA E. Sealants: The color of the sealant exposed shall be chosen from the manufacturer s standards. If unspecified, the sealant color shall be compatible with the window framing materials. 1. Non-working joints: Sealant shall comply with AAMA Window Components: Sealant shall be suitable for application specified and approved by the window manufacturer. 3. Perimeter: Sealant shall comply with AAMA 800 and Section F. Compression Type Gaskets: Provide compressible TPE stripping for glazing and weather stripping complying with ASTM D 1921, ASTM D 792, ASTM D 2240, ASTM D 412, ASTM D 590, and ASTM D 3835 molded TPE gaskets. 2.3 ACCESSORIES A. Muntins: Provide muntins in each designated sash to replicate the desired divided lite configuration. Muntins shall be of extruded or roll-formed aluminum. Muntins shall be rectangular or contour in shape, per architect s request. 1. True divided lite muntins: Provide an extruded aluminum muntin with a minimum nominal wall thickness of.080 inch. Finish to match windows. 2. Simulated Muntins: a) Roll Form Muntins: Provide simulated muntins suspended within the insulated glass units. b) Applied Muntins: Provide extruded tubular shaped aluminum muntins with a minimum wall thickness of.050 inch. Applied muntins shall be mechanically fastened to a surrounding extruded tubular shaped aluminum applied muntin frame with a minimum wall thickness of.050 inch. The applied muntin/frame system shall allow replacement of the glazing without removing or replacing the applied muntins. No exposed fasteners will be allowed. Finish to match windows.
6 B. Nailing fins: Nailing fins shall snap into main frame, be of extruded aluminum with a minimum wall thickness of.062 inch, be continuous with hair line joints at corners, and protrude a maximum of 2 1/2 inch past the window equal leg dimension. Nailing fins attached by means of fasteners or welding are not acceptable. C. Leg Extender: Leg extenders shall snap into main frame, be of extruded aluminum with a minimum wall thickness of.062 inch, and be continuous with hair line joints at corners. Leg extenders shall allow the interior leg and/or exterior leg of main frame to lengthen by a dimension up to 2 1/2 inch. Leg extenders shall be finished to match windows. Attachment by means of fasteners or welding is not acceptable. D. Mullions: Provide extruded aluminum mullions with a minimum nominal wall thickness of.062 inch and cover plates, where required, to complete window to window connections. E. Receptors: Provide two piece extruded aluminum receptors for the head and/or jambs of the window openings with a minimum nominal wall thickness of.062 inch. Provide one row of TPE gasket placed into extruded grooves in each receptor piece to ensure no window unit to receptor metal contact. Provide receptors with integral nailing fin, if required by the architect. Finish receptors to match windows. F. Subsills: Provide subsills with a minimum nominal wall thickness of.062 inch. Provide subsills with means to weep water to the exterior. Finish subsills to match windows. G. Panning: Provide extruded aluminum panning of the type and configuration required by the architect with a minimum nominal wall thickness of.062 inches. Provide one row of vinyl gasket placed into extruded grooves in each panning member to ensure no window unit to panning members. Clips shall be attached with stainless steel fasteners. Space stainless steel clips appropriately to allow the window units to secure themselves tightly to the panning. Window units shall lip over the panning sill member allowing water to weep to the exterior. Finish panning to match window units. H. Trims: Provide extruded aluminum trim of the type and configuration required by the architect with a minimum nominal wall thickness of.050 inches. Provide extruded aluminum trim clips, with a minimum nominal wall thickness of.050 inch, to allow attachment of the trim to the window units and/or openings. Finish trim to match window units. I. Dual Glazing: Window sash shall have ¼ exterior glazing, see section (08800) for specific glass types. Interior light shall be removable for maintenance and cleaning and be glazed with ¼ glass; see section (08800) for details. J. Internal Blinds: Blinds shall be 5/8 and be installed in the removable interior frame for ease of maintenance. Blinds must be operable from the interior of the building by means of a knob or custodial type hardware without removing the interior glazing panel.
7 2.4 FIXED WINDOWS A. Window Grade and Class: Comply with requirements of AAMA Grade and Performance for AW-PG Provide window units with a 4 minimum main frame depth. 2. Provide 1 maximum overall glazing thickness. See Section glass and glazing. B. Glazing Gaskets: Provide sliding-type gaskets. 1. Provide TPE gaskets placed into extruded grooves in glazing stop. a. Provide one row of TPE gasket at all glazing stops. C. Glazing: To be glazed to main frame with perimeter polyisobutylene and butylpolymer blend glazing tape. Foam tapes are not acceptable. 2.5 FABRICATION A. Fabricate components in accordance with manufacturer s tested assemblies. Remove burrs and ease edges. Shop fabricate to greatest extent practicable to minimum field assembly. Disassemble only to the extent necessary for shipping and handling limitations. B. Thermal Break: Manufacturer s standard integral urethane thermal barrier, located between exterior and interior members to provide thermal separation. Provide thermal break that has been tested for thermal conductance and has been in use a minimum of 5 years. 2.6 FINISHES A. Clear Anodized, Class I: Etched, medium matte, clear anodic coating, 0.7 mil thickness. Meeting AAMA and AA-M12C22A41. B. Color Anodized Class I: Etched, medium matte, colored anodic coating, 0.7 mil thicknesses. Meeting AAMA and AA-M12C22A Standard Color: Color as selected by architect from window manufacturer s full range of standard colors. a. Dark Bronze 2. Custom Colors: Color selected by architect from window manufacturer s full range of custom colors. a. Light Bronze b. Medium Bronze c. Black
8 C. Fluorocarbon, High Performance Paint Coating: Color as selected from manufacturer s full range of colors by architect. Fluorocarbon spray coating shall be applied by a licensed applicator and shall meet AAMA specifications. 1. Fluorocarbon 2-Coat System: Inhibitive primer and fluoropolymer color top coating of not less than 70 percent polyvinylidene fluoride complying with AAMA Prepare and pre-treat metal surfaces to comply with paint manufacturer s instructions. 2. Fluorocarbon 3-coat System: Inhibitive primer, fluoropolymer color coating, and clear fluoropolymer top coating complying with AAMA Fluoropolymer color and clear coats shall not have less than 70 percent polyvinylidene fluoride. Prepare and pre-treat metal surfaces to comply with paint manufacturer s instructions. D. High Solids Paint Coating: A high solids coating shall be applied by a licensed applicator and shall meet AAMA specifications. 1. Standard Colors: Color as selected by architect from window manufacturer s full range of standard colors. Prepare and pre-treat metal surfaces to comply with paint manufacturer s instructions. 2. Custom Colors: Color as selected by architect from paint manufacturer s full range of colors. Prepare and pre-treat metal surfaces to comply with paint manufacturer s instructions. PART 3 EXECUTION 3.1 INSPECTION A. Remove and properly dispose of existing windows in accordance with Section Verify that openings are dimensionally within allowable tolerances, plumb, level, and clean. Provide solid anchoring surfaces that are in accordance with approved shop drawings B. Verify that the opening into which the windows will be installed is the correct size to permit installation of the new windows according to the manufacturer s installation instructions. C. Do not install windows until unsatisfactory conditions are corrected. 3.2 INSTALLATION A. Install windows with skilled tradesperson in exact accordance with approved shop drawings. B. Aluminum that is not organically coated shall be insulated from direct contact with steel, masonry concrete or noncompatible materials by bituminous paint, zinc chromate primer, or other suitable insulating material. C. Install vapor retardant tape between window perimeter and adjoining collateral materials and existing wall barriers to insure continuity. D. Plumb and align window faces in a single plane for each wall plane. Erect square and true. Anchor to maintain position when subjected to normal thermal and building movement (seismic forces), and specified wind loads.
9 E. Install glass and glazing in accordance with approved shop drawings to provide satisfactory, leak-free installation. F. Perimeter Sealing: Seal joints at the perimeters in accordance with approved shop drawings to provide watertight installation. 1. Joints and surfaces to receive sealants shall be clean, free from loose material, free of effervescence or mortar leaking, and dry. Sealants shall not be applied when the temperature is below the sealant manufacturer s instructions. 2. Clean the joints and surfaces before sealing or priming. Then prime the joints in accordance with the sealant manufacturer s instructions. 3. Provide joint backing in all joints where a suitable backer to receive sealant is otherwise not available. Joint depth shall be equal to ½ of the width. 4. Caulk joint width shall not be less than ¼ inch not more than ½ inches unless otherwise recommended by the sealant manufacturer. Wipe off the excess material and leave the exposed surfaces and joints clean and smooth. 3.3 ADJUSTING A. After installation, windows and glazing shall be inspected and adjusted to provide smooth operation and a weathertight window system. 3.4 CLEANING A. After installation, leave windows clean and free of temporary labels and dirt. Protect finished installation against damage. B. Final cleaning of the anodized finish shall be in accordance with AAMA C. Final cleaning of the painted finish shall be in accordance with AAMA END OF SECTION 08520
CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com CASEMENT PROJECT OUT SERIES 6400
CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com CASEMENT PROJECT OUT SERIES 4400
HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA
HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA
HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA
DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA
SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4
GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com SINGLE HUNG SERIES 810 AAMA/WDMA/CSA
Signature Series 5 Lap SECTION ALUMINUM WINDOWS
Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this
Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION
Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division
2000/2100/2200 Series Heavy Commercial Sliding Patio Doors
2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO
SECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required
SECTION ALUMINUM STORM WINDOWS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable
SECTION EXPANSION CONTROL
SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL
Aluminum Flush Doors and Frames SPECIFICATIONS Section 081116 [8120] Cline Aluminum Doors, Inc. 112 32nd Avenue West Bradenton, FL 34205-8907 Toll-Free (800) 648-6736 Office (941) 746-4104 Fax (941) 746-5153
Model 8000 Double Hung H-C x 2311 (56 x 91 )
1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors
PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall
Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08900 ALUMINUM CURTAIN WALL This suggested guide specification has
SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
Corium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
Model 4000-IM Single Hung H-C x 2300 (56 x 91 )
1.01 GENERAL PROVISIONS: PART 1 - GENERAL Architect to edit the items in red. A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work
T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)
T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) FEATURES 1.) Available Configurations -Single hung -Oriel style (optional) 2.) Main frame / Sash -Drop-in glazing
GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM
1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window
DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS
DIVISION 8 OPENINGS SECTION 08 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
SECTION ROOF SPECIALTIES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
Section PANEL SIGNAGE
Section 10 14 23 PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including FDOT DIVISION I GENERAL REQUIREMENTS & COVENANTS Specification Sections,
SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)
SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text
SECTION 08260 SLIDING PATIO DOORS Display hidden notes to specifier by using Tools/Options/View/Hidden Text PART 1 GENERAL 1.1 SECTION INCLUDES A. Vinyl sliding patio doors (Spencer Walcott). 1.2 RELATED
TMS 114 XT TECHNICAL MANUAL
TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES is center set flush glazed systems that are 4 1/2" deep with a 2" wide sightline Glaze from the outside or inside Screw spline or shear block fabrication Glazing
GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM
1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY
ALL-ALUMINUM DOOR & WINDOW FRAMING
ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum
MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1
PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have
SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:
SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior storefront framing. 2. Storefront framing for ribbon walls. 3. Storefront framing
A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.
SECTION 08 51 13 - Page 1 PART 1 GENERAL 1.1 SUMMARY A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens. B. Related Sections: 1. Section 07 92 00
TMS 152 / 152T / 152XT TECHNICAL MANUAL
TMS 152 / 152T / 152XT TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES TMS 152 (non-thermal), 152T (single thermal barrier), and 152XT (double thermal barrier) are front set flush glazed systems that are
PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***
***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper
SECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
AUGUST, 2017 IR 500/501 Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs
AUGUST, 2017 IR 500/501 Framing 1 EC 97909-095 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS This suggested guide specification
SECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008
SECTION 085413 - FIBERGLASS WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)
Section 083213 - Sliding Aluminum Framed Glass Doors (2500 Model Specifications) I. GENERAL: SECTION 083213 SLIDING ALUMINUM- FRAMED GLASS DOORS 1.01 Scope of Work A. Furnish all necessary materials, labor,
SECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
WINDOW TECH SYSTEMS, INC. 3 ¼ HORIZONTAL SLIDING & FIXED ALUMINUM WINDOWS SPECIFICATIONS
SPECIFICATIONS The Wintech Series 6000 consists of 3 ¼ frame commercial aluminum windows with poured urethane thermal barriers. Model 6000 is a horizontal sliding window with a rating of HS C50 and Model
Repair Maintenance Hangar Phase II August 2010
SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include
PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW
08 46 3 GLAZED ALUMINUM WINDOW WALL PART - GENERAL A high-quality thermally broken 4 ½ aluminum window wall designed for residential high rise construction.. SUMMARY A. Section Includes: Glazed Aluminum
Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS
Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 DIVISION 08 / SECTION 08560, VINYL WINDOWS SPECIFICATIONS 1.0. Section includes: 1. All windows of the types and sizes as called for in this
REBCO ALUMINUM WINDOWS
REBCO ALUMINUM WINDOWS When you are looking for the perfect windows to enhance your building's facade, you can count on REBCO's experienced staff to assist you with product selection and design as well
A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.
SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division
SPECIFICATION SECTION PART 1 GENERAL
PART 1 GENERAL 1.01 Summary A. Furnish and install louvers, bird screens, blank-off panels, structural supports and attachment brackets as shown on the drawings, as specified, and as needed for a complete
ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 10530 PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
Guideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
Wall Louvers (10200)
Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses.
Sliding Patio Doors Brickmould Vinyl
TABLE OF CONTENTS Specifications... 7-2 QuickSpecGuide... 7-3 Elevations/Sizes: 1/8 Scale 2-WideSlidingPatioDoors... 7-4 GlazingOptions: 3 Scale... 7-5 Grille Patterns... 7-6 SectionDetails: 6 Scale...
NORTH TONAWANDA CSD Capital Projects 2015
SECTION 081743 - FRP DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 Specification
SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW
PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications
AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals
AQUARIUS CONDOMINIUM 2751 SOUTH OCEAN DRIVE HOLLYWOOD, FLORIDA 33019 40 YEAR RESTORATION PROJECT & RELATED WORK Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals ENGINEER S PROJECT # 7478-16
Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window
E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE BLAST GRADE Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** 3 7 8 Heavy Commercial Hung Thermal Window
Alply CLASSIC WALL Architectural Insulated Panel Wall System
SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated
SECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
SWING DOOR SPECIFICATION
SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified
SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW
SECTION 08 51 13 ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated in this section. B. Factory-installed
CS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs
MARCH, 2017 Trifab 451UT Framing 1 EC 97909-088 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS This suggested guide specification
A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.
SECTION 08800 - GLAZING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
SECTION PRE-ENGINEERED BUILDING INSULATION
PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered
SPECIFICATIONS: Architectural Aluminum Railings
PART ONE: GENERAL 1.1 SUMMARY SPECIFICATIONS: Architectural Aluminum Railings A. Work in this section includes custom and standard Interior and Exterior aluminum railings and guardrails. 1.2 PERFORMANCE
SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs
EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC 97909-19 08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 RELATED
SECTION TURBINE VENTILATORS
SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.
SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
Page 1 of 5
SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary
SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.
SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07200 - Joint Sealers. 2. 08800 - Glass and Glazing. 1.02 REFERENCES A. AAMA/NWWDA 101-97 Voluntary Specifications for
MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1
Page 1 This section includes AMBICO RFI/EMI Steel Shielding Steel Door and Frame assemblies. This section relies on both the Canadian Steel Door Manufacturers Association (CSDMA.org) industry standard,
A. Access doors and frames are part of an access door and frame allowance.
SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
SECTION LOUVERS AND VENTS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 90 00 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
SECTION DECORATIVE METAL FENCES AND GATES
SECTION 32 31 19 SPEC WRITER NOTE: Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section
Window Installation Instructions: Sliding Window Systems with Frame Master Receptor
STANDARD PROCEDURE No. I-181 Window Installation Instructions: Sliding Window Systems with Frame Master Receptor Examined, Accepted and Approved By: D. Ray Van Ness Title: President SUBJECT: Window Installation
Awning Windows Montecito New Construction Window
Awning Windows Montecito New Construction Window Full awning Double-top awning Double awning Double-bottom awning FULL DOUBLE BOTTOM/TOP DOUBLE AWNING - Min 1 3 1 4 Max 4 6 3 0 AWNING - Min 3 0 1 6 Max
SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS)
SECTION 08 52 00 ( ) PART 1 - GENERAL SPECIFIER NOTE: DATA CONTAINED IN THIS GUIDE SPEC IS ACCURATE AS OF AUGUST 2007. DUE TO ONGOING PRODUCT CHANGES, THIS DATA MAY CHANGE OVER TIME. CONSULT MANUFACTURER
PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS
SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
Casement Windows Montecito New Construction Window
Casement Windows Montecito New Construction Window Full casement Double-bottom casement FULL DOUBLE/SINGLE DOUBLE CASEMENT - Min 1 6 1 0 Max 3 0 5 0 or 2 6 6 0 CASEMENT - Min 3 0 1 6 Max 6 0 5 0 or 5 0
Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1
Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions
SECTION DECORATIVE METAL AND GLASS RAILING
SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,
SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.
1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation
A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.
SECTION 08462 - SWINGING AUTOMATIC ENTRANCE DOORS PART 1 - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division
WESTECK WINDOWS and DOORS
WESTECK WINDOWS and DOORS SECTION 08565 VINYL (PVC) PATIO DOOR GENERAL Supply PVC patio sliding doors as per approved Shop Drawings. PART 1 1.1 SECTION INCLUDES A. Patio sliding doors 1.2 RELATED SECTIONS
A. Pre-engineered, pre-finished extruded aluminum Pavilions.
10 73 00 SECTION Pavilions PART 1 GENERAL 1.1 SECTION INCLUDES A. Pre-engineered, pre-finished extruded aluminum Pavilions. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and Accessories. B. Section
by Rollfab Metal Products
by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and
COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100
COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,
TIE Aluminum Guide Spec: Thermally Improved Windows & Doors
TIE Aluminum Guide Spec: Thermally Improved Windows & Doors Thermally Improved Aluminum Windows (TIE) ALUMINUM WINDOWS - 08 51 13 With the thin lines that Milgard s TIE Aluminum Windows provide, they
Series x Thermal Triple Set Storefront Framing
Series 433 2 x 4 1 2 Thermal Triple Set Storefront Framing CONFIGURATIONS Screw Spline Shear Block System 433 is a thermally broken storefront framing system. Glass planes can be placed in an outside set,
Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017
SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
CENTRIA FORMABOND II Metal Composite Wall System
CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS
SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support
THERMALLY BROKEN STEEL WINDOWS STEEL WINDOW INSTITUTE A STANDARD OF EXCELLENCE
THERMALLY BROKEN STEEL WINDOWS A STANDARD OF EXCELLENCE STEEL WINDOW INSTITUTE WHY? Elegant Narrow Sightlines Superior Strength and Durability Unparalleled Security Structural Integrity Extra Deep Glazing
Series 510-I Thermal Heavy Commercial Projected Window
Windows Curtain Walls Entrances Storefronts Series 510-I Thermal 2-7 16 Heavy Commercial Projected Window Configurations Project-In Project-Out Casement Fixed Series 510-I retains an AAMA Architectural