UNIFIED FACILITIES GUIDE SPECIFICATIONS

Size: px
Start display at page:

Download "UNIFIED FACILITIES GUIDE SPECIFICATIONS"

Transcription

1 USACE / NAVFAC / AFCEC / NASA UFGS (August 2016) Preparing Activity: USACE Superseding UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated January 2018 SECTION TABLE OF CONTENTS DIVISION 09 - FINISHES SECTION WOOD STRIP AND PLANK FLOORING 08/16 PART 1 GENERAL 1.1 SUMMARY 1.2 REFERENCES 1.3 SUBMITTALS 1.4 CERTIFICATIONS Certified Sustainably Harvested Wood Indoor Air Quality Certifications Floor Covering Materials Paints and Coatings Adhesives and Sealants 1.5 DELIVERY, STORAGE, AND HANDLING 1.6 ENVIRONMENTAL REQUIREMENTS 1.7 SCHEDULING PART 2 PRODUCTS 2.1 PRODUCT SUSTAINABILITY CRITERIA Recycled Content of Wood Strip and Plank Flooring Certified Sustainably Harvested Wood Reduce Volatile Organic Compounds (VOC) (LOW-EMITTING MATERIALS) for Products Bio-based Content for Bamboo Products 2.2 STRIP FLOORING General Requirements Bamboo 2.3 NAILS 2.4 RESILIENT PADS 2.5 WALL BASE 2.6 MOISTURE BARRIER 2.7 CLIPS, ANCHOR CHANNELS AND INSULATION 2.8 ASPHALT PRIMER 2.9 ASPHALT MASTIC PART 3 EXECUTION SECTION Page 1

2 3.1 SURFACE CONDITIONS 3.2 INSTALLATION Gymnasium Floors Wood Sleepers Steel Channels Handball Court Floor and Walls Squash and Handball Court Walls Wood Supports Steel Supports 3.3 SANDING 3.4 PROTECTION -- End of Section Table of Contents -- SECTION Page 2

3 USACE / NAVFAC / AFCEC / NASA UFGS (August 2016) Preparing Activity: USACE Superseding UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated January 2018 SECTION WOOD STRIP AND PLANK FLOORING 08/16 NOTE: This guide specification covers the requirements for wood strip and plank flooring for gymnasiums, handball and squash courts, and other special purpose applications. Adhere to UFC Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). PART 1 GENERAL 1.1 SUMMARY NOTE: Wood strip flooring is very sensitive to ambient humidity conditions since all wood flooring will expand and contract as relative humidity varies. In order to keep the flooring manufacturer's warranty valid after installation, the areas in which the wood floors are installed must be adequately ventilated with natural or mechanical air circulation at all times during the life of the flooring. If prior experience at the site indicates that SECTION Page 3

4 relative humidity during sustained heating periods will fall below 35 percent, the office in charge of building maintenance should provide equipment to introduce moisture into the floored area when required; conversely, if relative humidity increases to 50 percent or higher at any time, measures should be taken to dry the floored area, including turning on the heat. At sites with humidity problems, the maintenance of the flooring may require: 1) The design of a localized HVAC system to also react to and automatically control ambient humidity conditions through the life of the flooring; or 2) Continuous monitoring of relative humidity with on the spot corrective actions, as needed, without altering the HVAC system. These alternatives could be very expensive or impractical. The designer, in the absence of local experience, should coordinate with local manufacturers to specify compatible floorings which have performed well locally; that is, the designer should check gymnasiums in the area when building a gymnasium floor; the same for handball courts, etc. Of course, the designer has the option of purchasing commercially available floating or sleeper systems specifically designed to reduce the possibility of buckling and cupping brought on by moisture buildup or specifying other types of flooring when a cost analysis (including all HVAC variations) indicates that wood strip flooring is not economical. This specification is written to allow the Contractor to build wood strip floorings for gymnasiums, handball and squash courts, and other special purpose applications but does not preclude the installation of competitive, manufacturer standard, integrated systems. 1.2 REFERENCES NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a Reference Identifier (RID) outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. SECTION Page 4

5 The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN FOREST FOUNDATION (AFF) ATFS STANDARDS (2015) American Tree Farm System Standards of Sustainability ASTM INTERNATIONAL (ASTM) ASTM D41/D41M (2011; R 2016) Standard Specification for Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH) CDPH SECTION (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers CSA GROUP (CSA) CSA Z (R2013) Sustainable Forest Management FOREST STEWARDSHIP COUNCIL (FSC) FSC STD (1993; Am 1996; Am 1999; Am 2002) Principles and Criteria for Forest Stewardship MAPLE FLOORING MANUFACTURERS ASSOCIATION (MFMA) MFMA GS (1999) Guide Specifications for Maple Flooring Systems NATIONAL WOOD FLOORING ASSOCIATION (NWFA) (formerly NOFMA) NOFMA Grading Rules (1999) Official Flooring Grading Rules PROGRAMME FOR ENDORSEMENT OF FOREST CERTIFICATION (PEFC) PEFC ST 2002:2013 (2015) PEFC International Standard Chain of Custody of Forest Based Products Requirements RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE FLOORSCORE IAQ Certification SCIENTIFIC CERTIFICATION SYSTEMS (SCS) SCS SCS Global Services (SCS)Indoor Advantage SECTION Page 5

6 SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SCAQMD Rule 1113 SCAQMD Rule 1168 (2016) Architectural Coatings (2017) Adhesive and Sealant Applications SUSTAINABLE FOREST INITIATIVE (SFI) SFI (2015) Standards, Rules for Label Use, Procedures and Guidance UNDERWRITERS LABORATORIES (UL) UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings 1.3 SUBMITTALS NOTE: Review submittal description (SD) definitions in Section SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a "G." Generally, other submittal items can be reviewed by the Contractor's Quality Control System. Only add a G to an item, if the submittal is sufficiently important or complex in context of the project. For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the "G" designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy projects. Use the "S" classification only in SD-11 Closeout Submittals. The "S" following a submittal item indicates that the submittal is required for the Sustainability enotebook to fulfill federally mandated sustainable requirements in accordance with Section SUSTAINABILITY REPORTING. Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects. SECTION Page 6

7 Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for [Contractor Quality Control approval.] [information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability enotebook, in conformance to Section SUSTAINABILITY REPORTING. Submit the following in accordance with Section SUBMITTAL PROCEDURES: SD-02 Shop Drawings Squash and Handball Court Walls; G[, [ ]] Strip Flooring; G[, [ ]] SD-03 Product Data Strip Flooring Bamboo Installation SD-04 Samples Strip And Plank Flooring SD-07 Certificates Certified Sustainably Harvested Wood Indoor Air Quality SD-11 Closeout Submittals 1.4 CERTIFICATIONS Recycled Content for Wood Strip and Plank Flooring; S Certified Sustainably Harvested Wood Strip and Plank Flooring; S Indoor Air Quality for Wood Strip and Plank Flooring; S Indoor Air Quality for Bamboo Flooring; S Indoor Air Quality for Resilient Pads; S Indoor Air Quality for Asphalt Primer; S Indoor Air Quality for Asphalt Mastic; S Biobased Content for Bamboo Flooring; S NOTE: Use certified sustainably harvested wood where suitable for application and cost effective. Sustainably Harvested Wood is a product which comes from a third-party Forestry Certification Program and thus carries certain characteristics: 1) SECTION Page 7

8 Protection of biodiversity, species at risk and wildlife habitat, sustainable harvest levels, protection of water quality, and prompt regeneration (e.g., replanting and reforestation); 2) Third-party certification audits performed by accredited certification bodies; 3) Publicly available certification audit summaries; 4) Multi-stakeholder involvement in a standards development process; 5) Complaints and appeals process. Designer must verify suitability, availability within the region, cost effectiveness and adequate competition before specifying these sustainably harvested wood certifications - if these conditions are verified for the project locale, include the following section. For projects pursuing LEED, delete certifications other than FSC; for all other projects pursuing third-party certification allow the entire list of third party certifications. [1.4.1 Certified Sustainably Harvested Wood Provide wood certified as sustainably harvested by FSC STD [, ATFS STANDARDS, CSA Z809-08, SFI , or other third party program certified by PEFC ST 2002:2013]. Provide a letter of Certification of Sustainably Harvested Wood signed by the wood supplier. Identify certifying organization and their third party program name and indicate compliance with chain-of-custody program requirements. Submit sustainable wood certification data; identify each certified product on a line item basis. Submit copies of invoices bearing certification numbers. ]1.4.2 Indoor Air Quality Certifications Submit required indoor air quality certifications in one submittal package. [ Floor Covering Materials NOTE: Include this subparagraph requiring low VOC content products when product will be located in offices or classrooms. Provide wood strip and plank flooring, bamboo flooring, and resilient pad products certified to meet indoor air quality requirements by FLOORSCORE, UL 2818 (GreenGuard) Gold, SCS Global Services Indoor Advantage Gold or provide validation by other third-party program that products meet the requirements of this paragraph. Product must meet emissions requirements of CDPH SECTION Provide current product certification documentation from certification body. ] Paints and Coatings Provide asphalt primer product certified to meet either emissions requirements of CDPH SECTION (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule Provide current product certification documentation from certification body. SECTION Page 8

9 Adhesives and Sealants Provide asphalt mastic products certified to meet either emissions requirements of CDPH SECTION (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule Provide current product certification documentation from certification body. 1.5 DELIVERY, STORAGE, AND HANDLING Deliver materials to the site in original unopened packages, bundles or containers and with all labels intact. Store flooring in fully covered, well ventilated areas protected from extreme changes in temperature and humidity. Flooring shall be maintained at an average moisture content of 6 to 9 percent. Temperature and humidity in the storage area shall closely approximate the temperature and humidity of the rooms in which the flooring is to be installed. 1.6 ENVIRONMENTAL REQUIREMENTS NOTE: The values stated in the guide specification for moisture content of the flooring and for the humidity and temperature of the space where the flooring will be installed are those which are generally suitable. When local experience has proven that values differing from those included in the guide specification are necessary because of geographical location or seasonal weather conditions, appropriate values will be substituted for the values stated in the guide specification. Provide permanent heating and air conditioning, installed and working, in rooms where wood flooring is to be installed or adequate arrangements for ventilation and temperature controls. The temperature shall be maintained at 14 to 27 degrees C 55 to 80 degrees F and the humidity shall be maintained [at [40] [ ] percent] [as recommended by the manufacturer] starting not less than 3 days prior to beginning the installation of flooring and continuing throughout the remainder of the contract period. 1.7 SCHEDULING Schedule strip and plank flooring work after any other work which would raise the moisture content of the flooring or damage the finished surface of the flooring. PART 2 PRODUCTS 2.1 PRODUCT SUSTAINABILITY CRITERIA For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following: [2.1.1 Recycled Content of Wood Strip and Plank Flooring NOTE: Use materials with recycled content, SECTION Page 9

10 calculated on the basis of post-industrial and post-consumer percentage content where appropriate for use. Designer must verify suitability, availability within the region, cost effectiveness and adequate competition (including verification of bracketed percentages included in this guide specification) before specifying product recycled content requirements. Recycled content is identified for some products in this section; provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT. Other products listed in this section may be available with recycled content; identify those products that meet project requirements for recycled content, and provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT. ][2.1.2 Certified Sustainably Harvested Wood NOTE: Use certified sustainably harvested wood where suitable for application and cost effective. Designer must verify suitability, availability within the region, cost effectiveness, and adequate competition before specifying these certifications. Certified sustainably harvested wood is identified for some products in this section; provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph BIOBASED PRODUCTS. Other products listed in this section may be available as certified sustainably harvested wood; identify those products that meet project requirements for certified sustainably harvest wood, and provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph BIOBASED PRODUCTS. ][2.1.3 Reduce Volatile Organic Compounds (VOC) (LOW-EMITTING MATERIALS) for Products Reduced VOC content is identified for some products in this section; provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph REDUCE VOLATILE ORGANIC COMPOUNDS (VOC) (LOW-EMITTING MATERIALS). Other products listed in this section may be available with reduced VOC content; identify those products that meet project requirements for reduced VOC content, and provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph REDUCE VOLATILE ORGANIC COMPOUNDS (VOC) (LOW-EMITTING MATERIALS). ][2.1.4 Bio-based Content for Bamboo Products NOTE: Use materials with biobased content where suitable for application and cost effective. Designer must verify suitability, availability within the region, cost effectiveness, and adequate competition (including verification of bracketed percentages included in this guide specification) before specifying product biobased content requirements. A resource that can be used to identify products with biobased content is the SECTION Page 10

11 "Catalog" tab within the USDA's "Biopreferred" website at Other products with biobased content are also acceptable when meeting all requirements of this specification. Biobased content is identified for some products in this section; provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph BIOBASED PRODUCTS. Other products listed in this section may be available with biobased content; identify those products that meet project requirements for biobased content and provide documentation in accordance with Section SUSTAINABILITY REPORTING paragraph BIOBASED PRODUCTS. ]2.2 STRIP FLOORING NOTE: Designer will select appropriate species and will permit maximum competition wherever possible; however, gymnasiums will be limited to hard maple. Flooring of 26 mm 33/32 inch) thickness should be considered when floors will be subjected to hard service and frequent sanding General Requirements NOTE: Use certified sustainably harvested wood where suitable for application and cost effective. Designer must verify suitability, availability within the region, cost effectiveness, and adequate competition before specifying this certification. NOTE: Use materials with recycled content, calculated on the basis of post-industrial and post-consumer percentage content where appropriate for use. Designer must verify suitability, availability within the region, cost effectiveness and adequate competition (including verification of bracketed percentages included in this guide specification) before specifying product recycled content requirements. Research shows the product is available among US national manufacturers above the minimum recycled content percentages shown below. Some manufacturers and regions have higher percentages. Based on research, insert desired minimum percentages into the empty set of brackets. Include last bracketed sentence requiring certification for indoor air quality when product will be located in offices or classrooms. Strip and plank flooring must be [19] [26] mm [3/4] [33/32] inch thick by 55 mm 2-1/4 inch face width, kiln dried, continuous tongue and groove and of standard lengths. Beech and birch shall be second grade in accordance with NOFMA Grading Rules[ and certified sustainably harvested wood strip SECTION Page 11

12 and plank flooring]. Hard maple must be second and better in accordance with MFMA GS [and certified sustainably harvested wood strip and plank flooring]. Red and white oak must be select grade in accordance with NOFMA Grading Rules [and certified sustainably harvested wood strip and plank flooring]. Provide wood products with no added urea-formaldehyde resins. Strip flooring must be marked with the trademark of the grading agency. Submit two samples of each type of strip and plank flooring. [Wood Strip Flooring must contain a minimum of [90][ ] percent reclaimed, salvaged, and recycled wood. Provide data identifying percentage of recycled content for wood strip and plank flooring.][ Provide certification of indoor air quality for wood strip and plank flooring.] [2.2.2 Bamboo NOTE: Use of materials, such as bamboo, with bio-based content is required where suitable for application and cost effective. Designer must verify suitability, availability with the region, cost effectiveness and adequate competition (including verification of bracketed percentages included in this section) before specifying product bio-based content requirements. A resource that can be used to identify products with bio-based content is the "Catalog" tab within the USDA's "Biopreferred" website at Use of other products which meet all requirements of this specification and contain bio-based content is also acceptable." Include last bracketed sentence requiring certification for indoor air quality when product will be located in offices or classrooms. Bamboo flooring must be laminated, tongue-and-groove plank flooring, [16 to 19 mm 5/8 to 3/4 inch thick, 2- or 3-ply, flat grain with horizontal laminations] [13 mm 1/2 inch thick with vertical laminations]. Provide bamboo products with minimum [75][ ] percent bio-based content. Submit data identifying percentage of biobased content for bamboo flooring.[ Provide certification of indoor air quality for bamboo flooring.] ]2.3 NAILS Provide nails in accordance with strip flooring manufacturer's recommendations. 2.4 RESILIENT PADS NOTE: Include last bracketed sentence requiring certification for indoor air quality when product will be located in offices or classrooms. Resilient pads must be pneumatic rubber, PVC, or polyurethane resilient SECTION Page 12

13 mounts to fit the selected floor system. [Provide certification of indoor air quality for resilient pads.] 2.5 WALL BASE Wall base must be wood molding or vented cove with premolded outside corners and mitered inside corners. 2.6 MOISTURE BARRIER Moisture barrier must be 0.15 mm 6 mil minimum thickness polyethylene. 2.7 CLIPS, ANCHOR CHANNELS AND INSULATION NOTE: Include this paragraph when channel anchorage system is specified. Channel anchorage system will be included as an option to wood nailers for gymnasium floors. Galvanized steel clips for steel channel anchorage systems must be in accordance with steel channel anchorage system manufacturer's recommendations. Clips mustbe designed to provide holding at least equal to the nailing specified and shall function without splitting the assembled boards or otherwise reducing the performance of the floor. Anchor channels must be as recommended by the flooring manufacturer. Anchor channels must be galvanized, complete with all pads, anchors and other components required for channel installation. Underfloor insulation must be asphalt impregnated fiberboard or closed-cell polyethylene foam. 2.8 ASPHALT PRIMER ASTM D41/D41M. Provide certification of indoor air quality for asphalt primer. 2.9 ASPHALT MASTIC As recommended by the flooring manufacturer. Provide certification of indoor air quality for asphalt mastic. PART 3 EXECUTION 3.1 SURFACE CONDITIONS Concrete slab must be level, steel troweled to a tolerance of 3 mm 1/8 inch plus or minus in a 3 m 10 foot radius. Slab surface must be clean, dry, and approved prior to start of installation. The slab must be depressed as required by the floor specified. 3.2 INSTALLATION Install flooring in accordance with the approved installation instructions of the manufacturer. Submit manufacturer's descriptive data and installation instructions. Wood nailers are specified in Section ROUGH CARPENTRY. Unless otherwise approved, flooring must be laid parallel to the length of the area to be floored. Strips must be laid [with close joints, snugly driven up but providing for absorption of a small amount of expansion] [to allow for intermediate expansion in accordance with humidity SECTION Page 13

14 conditions expected during the life of the flooring]. End joints must be so alternated that there will be at least two boards between end joints in the same plane and at least 150 mm 6 inches between end joints in adjacent boards. Space for expansion must be left along perimeter walls and around fixed projections through the floor surface. Unless otherwise shown or permitted by the approved installation instructions, expansion space shall be 5 mm per meter 1/16 inch per foot of distance between opposite walls, with one half the space provided at each wall and with a minimum space of 25 mm 1 inch at each wall. Do not install building construction materials that show visual evidence of biological growth Gymnasium Floors Wood Sleepers For wood sleeper supported floors, the slab must be vapor-sealed with a two-ply membrane and hot-poured, steep-slope asphalt to a minimum depth of 6 mm 1/4 inch above bottom of sleepers. Anchored, treated wood sleepers must be spaced at 400 mm 16 inches on center with wood or plywood subfloor or, if required by design considerations, wood sleepers at 300 mm 12 inches on centers without subfloor and with 26 mm 33/32 inch thick flooring. Space between rows of wood sleepers must be left vacant. Expansion joints must be 50 mm 2 inches maximum Steel Channels Galvanized steel channel system must be placed on manufacturer's standard grooved foam or grooved resilient insulation board. Expansion joints must be in accordance with manufacturer's recommendations Handball Court Floor and Walls Strip flooring used for floors and walls in handball courts must be laid out to provide an overall light appearance; contrast from one board to the next must be gradual in order to avoid dark streaks Squash and Handball Court Walls Maximum space for expansion must be 50 mm 2 inches at each wall. Expansion joints over 25 mm 1 inch and expansion joints for steel channel-strip flooring application must be detailed and the drawings, showing the method of covering, submitted for approval Wood Supports Anchored wood supports must be used to keep the treated wood sleepers shimmed away from the wall to provide ventilation. Wood sleepers must be spaced at 400 mm 16 inches on center. Exterior grade plywood 15 mm 5/8 inch thick, with two coats of aluminum enamel on the back side in accordance with Section ROUGH CARPENTRY, must be used for vapor seal and sound deadener Steel Supports Anchored, galvanized, steel channel supports must be used with steel channel system; steel channels must be spaced at 300 mm 12 inches on center. The space between the supporting wall and the back of the finished SECTION Page 14

15 wall must be filled to within 300 mm 12 inches of the ceiling with an approved hot-poured, steep-slope asphalt as the construction of the wall progresses. As an option to the asphalt-backed wall construction when 26 mm 33/32 inch thick flooring is used, the wall must be vapor sealed with a 0.15 mm 6 mil thickness of polyethylene sheeting prior to application to steel channels and the space between the supporting wall and the back of the finished wall must be filled with insulation as used for the floor. 3.3 SANDING Sand flooring to a smooth, even, uniform finish without burns. Make a minimum of three sanding cuts, each with a finer sandpaper. Use a heavy drum-type sander for floors, except a disc-type sander is permitted for the final cut on strip flooring. Either the first pass or the second pass of the drum-type sander shall be at an angle of 45 degrees to the grain; other passes of the drum-type sander shall be in the direction of the grain of strip flooring. Finish edges not reached by the sander with an edger or by hand methods. Perform the final sanding at a time and in a manner that will permit application of the first seal coat as specified in Section PAINTS AND COATINGS to be completed within 8 hours after completion of sanding. Leave the flooring clean and ready to receive the finishing materials. 3.4 PROTECTION Protect flooring from damage from the time of installation until final acceptance. -- End of Section -- SECTION Page 15

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-09 66 23 (August 2016) --------------------------- Preparing Activity: USACE Superseding UFGS-09 66 23 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-03 11 13.00 10 (May 2014) --------------------------------- Preparing Activity: USACE Superseding UFGS-03 11 13.00 10 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 22 13 (August 2016) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 22 13 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 48.00 10 (October 2006) ---------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 48.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 22 26.13 (August 2016) ------------------------------ Preparing Activity: NAVFAC Superseding UFGS-10 22 26.13 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-06 17 19 (November 2016) ----------------------------- Preparing Activity: USACE New Section UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.19 (August 2014) ------------------------------ Preparing Activity: NAVFAC Superseding UFGS-31 31 16.19 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

CHAMPAIGN CENTRAL HIGH SCHOOL COMBES GYM FLOOR REPAIR. A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty.

CHAMPAIGN CENTRAL HIGH SCHOOL COMBES GYM FLOOR REPAIR. A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty. SECTION 096400 - WOOD FLOORING PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty. B. Game lines and logos: Contractor shall

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.13 (August 2016) -------------------------------- Preparing Activity: NAVFAC Superseding UFGS-31 31 16.13 (November 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION 09 64 66 WOOD ATHLETIC FLOORING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wood athletic flooring including

More information

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards. WOOD FLOORING GENERAL INFORMATION 1.1 This section applies to factory finished wood strip flooring. 1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards. 1.3

More information

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 16 19 (January 2007) ---------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-07 16 19 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-03 01 30.71 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-03930 (September 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-05 14 00.13 (May 2015) -------------------------------- Preparing Activity: NASA Superseding UFGS-05 14 00.13 (November 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC INSTRUCTIONS FOR EDITING AND COORDINATION SECTION 09560 WOOD FLOORING - ATHLETIC 1. 1.02 Summary of Work: Edit Scope of Work to fit project requirements. 2. 2.01 (C) Flooring Systems: Delete system types

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 14 00 (February 2012) Change 2-02/18 ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 14 00 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 01 52 (August 2009) --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

SECTION WOOD AND ATHLETIC FLOORING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION WOOD AND ATHLETIC FLOORING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 096466 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 21 23 (May 2011) Change 3-08/15 --------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 21 23 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

1. Division 09 Section "Rough Carpentry."

1. Division 09 Section Rough Carpentry. GREENSPOINT AND LAUDER RD. EC/PRE-KlK PAGE 1 SECTION 096400 - WOOD FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING PART 1 GENERAL 1.1 SECTION INCLUDES A. Supply and installation of MFMA Maple Wood Flooring System B. Application of the game lines C. References for the correct construction and preparation of concrete

More information

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945 Revised on 11/17/11. Supercedes all previous versions. Check website for updates. DIVISION 9 - SECTION 09 60 00.11 QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945 PART 1.0-

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 22 19 (August 2017) --------------------------- Preparing Activity: USACE Superseding UFGS-10 22 19 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

SECTION WOOD GYMNASIUM FLOORING

SECTION WOOD GYMNASIUM FLOORING HORNER SAFE 2 SYSTEM Page 1 of 3 SECTION 096466 --- WOOD GYMNASIUM FLOORING PART 1-GENERAL 1.1 DESCRIPTION A. This document specifies a wood strip athletic floor system consisting, in general, of wood

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-06 71 33 (February 2015) ----------------------------- Preparing Activity: NASA Superseding UFGS-06 71 33 (May 2012) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

(August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS **************************************************************************

(August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** USACE / NAVFAC / AFCEC / NASA UFGS-02 42 91 (May 2010) ------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS SECTION TABLE

More information

PREFINISHED WIDE PLANK BAMBOO FLOORING Teragren Craftsman II

PREFINISHED WIDE PLANK BAMBOO FLOORING Teragren Craftsman II PREFINISHED WIDE PLANK BAMBOO FLOORING Teragren Craftsman II FloorScore -certified; FSC-Pure by special order 12715 Miller Road NE, Suite 301 Bainbridge Island WA 98110 Tel: 206.842.9477 Toll-free: 800.929.6333

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

ActionCush II Floating Resilient Floor System

ActionCush II Floating Resilient Floor System Floating Resilient Floor System SPORTS FLOOR SPECIFICATIONS Action Floor Systems, LLC 4781 N. US Hwy 51 Mercer, WI 54547 toll free: 800-746-3512 voice: 715-476-3512 fax: 715-476-3585 email: info@actionfloors.com

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-01 74 19 (January 2007) Change 2-05/15 ---------------------------- Preparing Activity: USACE Superseding UFGS-01 74 19 (October 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UFGS-03151A (September 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-03151A (September 2003) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-03 15 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE (CW) Replacing without change UFGS-03151A (September 2003) UNIFIED FACILITIES

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-40 17 30.00 40 (May 2016) ----------------------------------- Preparing Activity: NASA Superseding UFGS-40 17 30.00 40 (August 2010) UFGS-23 31 13.20 40 (February 2009)

More information

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-13 21 48 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-13034 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 92 00 (August 2016) Change 1-08/17 ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 92 00 (February 2016) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated January 2017

UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated January 2017 USACE / NAVFAC / AFCEC / NASA UFGS-01 20 00.05 20 (January 2012) Change 1-09/15 Change 2-03/17 ----------------------------------- Preparing Activity: NAVFAC Superseding UFGS-01 20 00.05 20 (February 2011)

More information

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945 April 7 th, 2017- The document is provided solely as a convenience for spec writers in the drafting process. Ecore will not be held responsible for the use or alteration of any information contained herein.

More information

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 11 73 (January 2007) ---------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-08 11 73 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-07 22 00 (February 2016) Change 1-02/17 ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 22 00 (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATION

UNIFIED FACILITIES GUIDE SPECIFICATION USACE / NAVFAC / AFCEC / NASA UFGS-07 13 53 (February 2016) Change 1-08/17 ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 13 53 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATION

More information

SECTION (SECTION 06160) SHEATHING SPECIFIER NOTE:

SECTION (SECTION 06160) SHEATHING SPECIFIER NOTE: This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Section Wood Grille Ceiling Panels

Section Wood Grille Ceiling Panels Section 095426 Wood Grille Ceiling Panels PART 1 GENERAL RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification sections

More information

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING General notes to the specifier: SECTION 09 64 29 PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING This is a template: edit this specification carefully to suit specific project requirements. Following

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 71 13.13 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replace without change UFGS-10716 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION LINEAR WOOD CEILINGS

SECTION LINEAR WOOD CEILINGS SECTION 09 54 24 LINEAR WOOD CEILINGS Copyright 2015 Madrid Inc. Section number and title complies with the Construction Specifications Institute s (CSI s) MasterFormat. Specification format conforms to

More information

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT # SECTION 018113.13 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes general requirements and procedures for compliance with certain USGBC LEED prerequisites and credits needed for Project to obtain LEED

More information

CONNOR PERMAFLEX & PERMAFLEX II Page 1 of 5

CONNOR PERMAFLEX & PERMAFLEX II Page 1 of 5 CONNOR PERMAFLEX & PERMAFLEX II Page 1 of 5 SECTION 09642 WOOD GYMNASIUM FLOORING PART 1 - GENERAL 1.1 DESCRIPTION A. Related work specified under other sections. 1. CONCRETE SUBFLOORS - SECTION 03 _ a.

More information

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board SECTION 09260 GYPSUM WALLBOARD SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Gypsum board at new wall partitions or where indicated on drawings. 1.2 REFERENCED STANDARDS A. ASTM C36 - Gypsum Wallboard

More information

GUIDE SPECIFICATION

GUIDE SPECIFICATION GUIDE SPECIFICATION 09 64 33.01 940 Centre Circle, Suite 1000 Altamonte Springs, FL 32714 Telephone: 407-260-9910 Fax: 407-260-9933 Toll Free: 800-800-5247 Web Site: http://www.kahrs.com This Guide Specification

More information

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements. SECTION 09 64 29 PREFINISHED FSC MAPLE FLOORING General notes to the specifier: This is a template: edit this specification carefully to suit specific project requirements. Following guidelines established

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-32 31 26 (April 2008) -------------------------- Preparing Activity: USACE Superseding UFGS 32 31 26 (January 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

ACOUSTICAL WALL TREATMENT SECTION 09840

ACOUSTICAL WALL TREATMENT SECTION 09840 ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-01 11 00 (August 2015) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-01 11 00 (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER PART 1.0 GENERAL 1.1 SECTION INCLUDES A. Resilient Flooring, including recycled rubber flooring. 1. Types: Types of recycled rubber resilient

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-12 36 00 (August 2016) Change 1-11/16 --------------------------- Preparing Activity: NASA Superseding UFGS-12 36 00 (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION (SECTION 09650) - RESILIENT FLOORING SPECIFIER NOTE:

SECTION (SECTION 09650) - RESILIENT FLOORING SPECIFIER NOTE: This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,

More information

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATION

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATION USACE / NAVFAC / AFCEC / NASA UFGS-02 84 16 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-13286 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATION References

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-34 73 13 (April 2008) Change 1-11/14 -------------------------- Preparing Activity: USACE Superseding UFGS-34 73 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-32 11 16.16 (November 2011) -------------------------------- Preparing Activity: NAVFAC Superseding UFGS-32 11 16.16 (July 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 14 00 (August 2016) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-08 14 00 (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6 Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6 Installing a Subfloor Over Concrete 27 24 National Wood Flooring

More information

GUIDE SPECIFICATION

GUIDE SPECIFICATION GUIDE SPECIFICATION 09 64 33.01 Kährs Canvas Collection 940 Centre Circle, Suite 1000 Altamonte Springs, FL 32714 Tim Colgan Telephone: 407-492-2441 Fax: 407-260-9933 Tim.colgan@kahrs.com Web Site: http://www.kahrs.com

More information

Advance NG (6mm) Technical Specification Sheet

Advance NG (6mm) Technical Specification Sheet Specifier Note: This Specification has been created to assist in preparing a Project or Master Specification. In accordance with Construction Specifications Institute (CSI) s MasterFormat, this Specification

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 01 8113.53 - SUSTAINABLE DESIGN REQUIREMENTS - GREEN GLOBES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE MANNINGTON COLORFIELDS SHEET RUBBER FLOORING Section 09 65 16 Sheet rubber Flooring (Thermoset Rubber) Created May 2012 Mannington Mills, Inc. P. O. Box

More information

toxicity/ieq: While many media can be very toxic during production, most are considered inert when cured/compete.

toxicity/ieq: While many media can be very toxic during production, most are considered inert when cured/compete. This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-13 48 00.00 10 (October 2007) ---------------------------------- Preparing Activity: USACE Superseding UFGS-13 48 00.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

B. Related Sections: 1. Division 07 Section Joint Sealants for sealing of expansion, contraction, control, and isolation joints in tile surfaces. SECTION 093000 - CERAMIC TILE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore August 15 th, 2016 - This document is provided solely as a convenience for spec writers in the drafting process. Ecore will not be held responsible for the use or alteration of any information contained

More information

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring Specifier Note: the following CSI (Construction Specifications Institute) section describes the resilient flooring system to be installed on the specific project. The number and title of the section may

More information

SECTION (SECTION 06100) ROUGH CARPENTRY SPECIFIER NOTE:

SECTION (SECTION 06100) ROUGH CARPENTRY SPECIFIER NOTE: This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,

More information

SECTION TERRAZZO FLOOR TILE

SECTION TERRAZZO FLOOR TILE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 66 16 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // ----- // if not applicable to project. Also delete any other item or

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-09 30 10 (August 2017) ---------------------------- Preparing Activity: USACE Superseding UFGS-09 30 10 (November 2013) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

UFGS (February 2009) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (February 2009) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-40 17 30.00 40 (August 2010) Change 1-11/12 ----------------------------------- Preparing Activity: NASA Superseding UFGS-23 31 13.20 40 (February 2009) UNIFIED FACILITIES

More information

by Rollfab Metal Products

by Rollfab Metal Products by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

A. Product Data: For each type of process and factory-fabricated product.

A. Product Data: For each type of process and factory-fabricated product. SECTION 061000 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Framing with dimension lumber. 2. Framing with engineered wood products. 3. Shear wall panels. 4. Rooftop equipment bases and support

More information

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial December 5th, 2017-This document is provided solely as a convenience for spec writers in the drafting process. Ecore Commercial will not be held responsible for the use or alteration of any information

More information

Section SoundPly LR M25 Acoustic Ceiling Panels

Section SoundPly LR M25 Acoustic Ceiling Panels Section 095126 Acoustic Ceiling Panels PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY A. Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1

More information

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension. SECTION 06 10 53 - MISCELLANEOUS ROUGH CARPENTRY PART 1 - [Editor: Display hidden text before editing.] 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

HPL CSI 3-PART SPECIFICATION FORM

HPL CSI 3-PART SPECIFICATION FORM MARCH 2013 HPL CSI 3-PART SPECIFICATION FORM Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part

More information

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 35 33.00 40 (August 2013) --------------------------------- Preparing Activity: NASA Superseding UFGS-26 35 33.00 40 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UFGS (February 2014)...UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (February 2014)...UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-12 48 13 (August 2017) -------------------------------- Preparing Activity: NASA Superseding UFGS-12 48 13 (February 2014)...UFGS-12 48 13 13(February 2011) UNIFIED FACILITIES

More information

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING P.O. Box 599 - Mars, PA 16046 800-321-3337 SECTION 07555 COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

Acoustic Ceiling Products (ACP) Fasäde Thermoplastic Panels Section Digicon Information Inc. Page 1

Acoustic Ceiling Products (ACP) Fasäde Thermoplastic Panels Section Digicon Information Inc. Page 1 Digicon Information Inc. Page 1 This section includes PVC ceiling panels for surface mounting or t-bar grid, and accessories. Panels are non-fire rated. This section includes proprietary and descriptive

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-32 12 13 (May 2017) --------------------------- Preparing Activity: USACE Superseding UFGS-32 12 10 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards SECTION 07185 TRAFFIC MEMBRANE PART 1 GENERAL 1.1 SECTION INCLUDES A. Traffic membrane, consisting of welded seam PVC waterproofing, over f following surfaces: 1. Decks, balconies, and sun porches 2. Walkways,

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING SECTION 07 13 26 SELF-ADHERING SHEET WATERPROOFING This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction

More information

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM SECTION 03 54 00 1 GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM PART 1 GENERAL 1.01 SUMMARY A. This is the recommended

More information

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1522 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 09 00

More information

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring Specifier Note: the following CSI (Construction Specifications Institute) section describes the resilient flooring system to be installed on the specific project. The number and title of the section may

More information