Durability, Concrete, Environment and Sustainability in the Eurocodes
|
|
- Cori Atkinson
- 6 years ago
- Views:
Transcription
1 Durability, Concrete, Environment and Sustainability in the Eurocodes Steinar Leivestad Standard Norge
2 Norwegian clients asks for environmentalfriendly concrete in 70 80% of all new contracts voluntarily Zero-emission building in Trondheim 2
3 Norwegian Concrete - the past and - the future We have great expectations to the general applicability of the Eurocodes
4 Development of the concrete-material Prime drivers; Sutainability Environmental- and CO 2 - footprint New cements and new binder combinations Utilize gain in strength from 28- to 91-days Re-use of aggregates Other??? Consequences with respect to Durability Strength and strength development Mechanical properties in design There are two perspectives To save the world (+ 2 0 C) To save the concrete (by maintaining its competitive position) Reduced concrete volume for same function Less CO 2 per m 3 used Account made up after end of life-cycle 4
5 Development on the material side will normally lead to changes in performance, the requirements must be able to accommodate this in an effective way With todays «Deemed to Satisfy» (DtS) will new materials have to be documented to show «equivalence» based on a material (CEM I) that is expected not to remain available in the future, and which show large variations in performance even within the same class With performance based design we have a discipline that is not yet mattured enough for daily use, where the selection of parameters gives much room for «optimistic» and «pessimistic» choices with large variations in results. The parameters should therefore be made on a neutral basis as part of the standardization. By use of «Exposure Resistance Classes» (ERC) we can have a performance based definition of classes, and the standards can give a calibrated set of requirements to; Exposure Class / Exposure Resistance Class / cover to reinforcement dependant of Design Working Life. 5
6 Material resistance classes The Ganeral provisions applies Durability Design of concrete structures Provisions coordinated between the various standards Interface Society / construction project Societal expectations + National legislation Eurocode Basis of structural design TC250 Basic requirement Eurocode Actions on structures TC250/SC1 Eurocode Design of concrete structures TC250/SC2 Design provisions EN Execution of concrete structures TC104/SC2 Ececution requirements EN Concrete TC104/SC1 ISO 6934 or ETA Tendons & PT kits EN reinforcement EN xx or ETA Prefabricated elements TC229 Product and testing standards TC104/SCs and WGs Product and testing standards Product and testing standards Product and testing standards
7 Meetings of TC250/SC2 and TC104/SC1 dealing with Durability and the work of the JWG TC250/SC2 TC104/SC1 or TC104 2/ Larnaca (20) Mentioned Brussels (23) Mentioned 17-18/ Helsinki (24) Discussed 13-14/ Stockholm (21) Pre mature, established TG / Brussels (25) Resolution / Berlin (22) Discussed Resolution / Torino (26) Discussed 7-8/ Budapest (27) Discussed 16-17/ Gent (23) Discussed Resolution / London (28) Discussed 07-08/ Madrid (29) Discussed 15-16/2010 Delft (24) No discussion Presentation TC104 30/ Oslo (30) Presentation Helsinki (25) No discussion 12-13/ Milan (31) Principles 23-24/ Milan (26) Principle agreed agreed 28-29/ Brussel (32) Discussed Berlin (27) No discussion 01/ Berlin (33) Discussed 20-21/ Paris (28) Discussed 19/ Ispra (34) Principles agreed 5-6/ Vienna (29) Discussed 22-23/ Workshop in Brussels convened by JWG 04/ Berlin (35) Discussed 5-6/ Brussels (30) Discussed Resolution 440 agreed 05/ Berlin (36) Reported Berlin (37) Reported 10-11/ London (31) SC1/WG1 Road map discussed Zürich (38) Reported The work on durability and the development of the concept by the JWG has been thorougly presented and discussed in TC250/SC2 and TC104/SC1since
8 Eurocode 2 Section 4 NDPs (5) The minimum cover values for reinforcement and prestressing tendons in normal weight concrete taking account of the exposure classes and the structural classes is given by cmin,dur. Note: Structural classification and values of c min,dur for use in a Country may be found in its National Annex. The recommended Structural Class (design working life of 50 years) is S4 for the indicative concrete strengths given in Annex E and the recommended modifications to the structural class is given in Table 4.3N. The recommended minimum Structural Class is S1. The recommended values of c min,dur are given in Table 4.4N (reinforcing steel) and Table 4.5N (prestressing steel). Cover Table 4.3N - 4.5N out of 27; 7 use recommended value 5 use recommended value with conditions 15 use ammended values Systematic review 30 comments 8
9 Exposure resistance classes system and definitions System Corrosion of reinforcement Deterioration of concrete Carbonation Resistance Class Low Medium Chloride Resistance Freeze/thaw Resistance Chemical Aggressiveness Class Class Class High Medium High Medium High High Low Medium Definitions Corrosion of reinforcement Deterioration of concrete Carbonation Resistance Class RXC RXC RXC Chloride Resistance Class RXSD RXSD RXSD Freeze/thaw Resistance Class RXF RXF Chemical Aggressiveness Class (for later) RXCA RXCA (Low) (Medi- (High) (Low) (Medi- (High) (Medium) (High) (Medium) (High) um) um) Void, not mature Definition of class is 50- Definition of class is 50- Definition of class is 50- Definition of class is 50- years of exposure to XC3 years of exposure to XS2, years of exposure to XF4, years of exposure to XA3, (Rh 65%) with 10%- with 10%-probability of with 10%-probability of ground water with SO 2 4 probability of carbonation chloride concentration scaling loss exceeding 6000mg/l and 10%- front exceeding (mm) exceeding 0,5% at depth (kg/m 2 ) probability of loss (mm) exceeding (g/m 2 )[??] ?? 9
10 Quoting fib State of the Art report on chloride ingress Would not going from left to right be nice 10
11 Draft proposal for text in EN Exposure resistance classes, continued (2) Concrete can be documented for the various classes in Table 2 by testing in accordance with the listed testing standards and with the limiting values given in Table 3. Table 3 Exposure resistance classes, limiting values and applicable test standards Carbonation resistance class RXC Chloride resistance class RXSD Frost resistance class RXF Limiting value, estimated after 50 years (mm) or kg/m 2 Classification standard RXC20 RXC30 RXC40 RXSD45 RXSD60 RXSD75 RXF0,5 RXF1, ,5 1,0 pren /12 EN CEN/TS CEN/TR (3) Concrete may also as an alternative to testing according to (2) be documented by applying the deemed to satisfy values in Annex F for the various cement/binders, water/binder ratios and minimum binder content. 11
12 PROPOSAL EN 206 Annex F Table F.1 Exposure resistance classes; deemed to satisfy values for various binder compositions (example, preliminary values) Tentative - Preliminary values Carbonation resistance class RXC Chloride resistance class RXSD Frost resistance class RXF RXC20 RXC30 RXC40 RXSD45 RXSD60 RXSD75 RXF0,2 RXF0,5 RXF1,0 Cement type or equivalent binder combination CEM I CEM II-A CEM II-B CEM III-A CEM III-B Maximum w/b-ratio b is the sum of cement and additions in the concrete, within the limits defining the cements according to EN ,55 0,60 0,65 NA NA 0,45 1 0,40 0,45 0,50 0,45 0,55 0,65 0,40 0,50 0,60??? 0,40 0,50 0,60 0,40 0,50 0,60??? NA 0,45 0,55?????? NA NA 0,45 0,38 0,45 0,55??? Minimum binder content (kg/m 3 ) Minimum air entrainment 4% 4% - 1 CEM I shall only be used with minimum 4% silica fume NA means that no deemed to satisfy values are given for that combination of binder and resistance class 12
13 The large scatter among the curves show how different the various cements within one cement type can perform with the same w/c-ratio 13
14 Alternative more refined approach distinguishing between various binders in Annex F of EN206 Preliminary values Cement type or equivalent binder combination CEM I Carbonation resistance class RXC Chloride resistance class RXSD RXC20 RXC30 RXC40 RXSD45 RXSD60 RXSD75 Frost resistance class RXF Maximum w/b-ratio b is the sum of cement and additions in the concrete, within the limits defining the cements according to EN ,55 0,60 0,65 NA NA 0,45 1 0,40 0,45 0,50 CEM II-A- V 0,45 0,55 0,65 0,40 0,50 0,60 S D L LL M CEM II-B- V 0,40 0,50 0,60 0,40 0,50 0,60 S D L LL M CEM III-A S NA 0,45 0,55??? CEM III-B S NA NA 0,45 0,38 0,45 0,55 Minimum binder content (kg/m 3 ) CEM I shall only be used with minimum 4% silica fume NA means that no deemed to satisfy values are given for that combination of binder and resistance class RXF 0,2 RXF 0,5 14 RXF 1,0
15 Exposure classes rate of carbonation and risk of corrosion 15
16 16
17 Class designation Description of the exposure Informative examples and comments 1 No risk of corrosion or attack For concrete without reinforcement or X0 embedded metal: all exposures except where there is freeze/thaw, abrasion or chemical attack 2 Corrosion induced by carbonation Where concrete containing reinforcement or other embedded metal is exposed to air and moisture, the exposure shall be classified as follows: XC1 Dry Concrete inside buildings with low air humidity, where the risk of corrosion is insignificant XC2 Wet or permanently high humidity, rarely dry Concrete surfaces subject to long-term water contact or permanently submerged in water or permanently exposed to high humidity. Many foundations, water containments (not external). Note: Leaching could also cause corrosion (see (5), XA classes). XC3 Moderate humidity Concrete inside buildings with moderate humidity External concrete sheltered from rain XC4 Cyclic wet and dry Concrete surfaces subject to cyclic water contact, (e.g. external concrete not sheltered from rain as walls, fassades, concrete in the tidal zone). 3 Corrosion induced by chlorides Where concrete containing reinforcement or other embedded metal is subject to contact with water containing chlorides, including de-icing salts, from sources other than from sea water, the exposure shall be classified as follows: XD1 Moderate humidity Concrete surfaces exposed to airborne chlorides XD2 Wet, rarely dry Swimming pools Concrete components exposed to industrial waters containing chlorides Note: If the chloride content of the water is 0.5 g/l then XD1 applies. XD3 Cyclic wet and dry Parts of bridges exposed to water containing chlorides Concrete roads, pavements and car park slabs in areas where de-icing agents are frequently used 4 Corrosion induced by chlorides from sea water Where concrete containing reinforcement or other embedded metal is subject to contact with chlorides from sea water or air carrying salt originating from sea water, the exposure shall be classified as follows: XS1 Exposed to airborne salt but not in direct Structures near to or on the coast, contact with sea water XS2 Permanently submerged Parts of marine structures and structures in seawater XS3 Tidal, splash and spray zones Parts of marine structures and structures directly over sea water 5. Freeze/Thaw Attack (XF classification is not necessary in cases where freeze/thaw cycles is rare) XF1 Moderate water saturation, without deicing Vertical concrete surfaces exposed to rain and freezing agent XF2 Moderate water saturation, with de-icing Vertical concrete surfaces of road structures exposed to freezing and airborne de-icing agents agent XF3 High water saturation, without de-icing Horizontal concrete surfaces exposed to rain and freezing agents XF4 High water saturation with de-icing agents or sea water Road and bridge decks exposed to de-icing agents Concrete surfaces exposed to direct spray containing de-icing agents and freezing Splash zone of marine structures exposed to freezing 6. Chemical attack XA1 Slightly aggressive chemical environment Natural soils and ground water according to Table 4.2 XA2 Moderately aggressive chemical Natural soils and ground water environment according to Table 4. 2 XA3 Highly aggressive chemical environment according to Table 4.2 Natural soils and ground water EN 1992 Table 4.1: Exposure classes related to environmental conditions Proposed changes; - X0 only for concrete without reinforcement - XC1 deleted permanently wet -XC2 added permanently wet 17
18 New 18
19 PROPOSAL in EN Table 4.4: Minimum concrete cover c min,dur dependant on design working life, exposure class and exposure resistance class Preliminary values Exposure Class EC Minimum cover for 50 and 100 years design working life, (preliminary values, values are rounded to nearest 5 mm) RXC20 2 RXC30 2 RXC years 100-years 50-years 100-years 50-years 100-years XC XC XC XC RXSD45 RXSD60 RXSD75 6 XD XS XD NA XS NA XD NA XS NA 1 Concrete corresponding to RXC10, with k N,90 1,4 mm/year 0,5 may be designed with c min = max {c min,b ; 10 mm} 2 The values are given for slab type geometry in beams the cover shall be increased by 5mm in RC20 and by 10 mm in RC30 and RC40 for exposure classes XC2, XC3, XC4, 3 In saline waters with chloride level below 2,0 % the minimum cover may be reduced by 10 mm, with a chloride level below 1,0 % the cover may be reduced by 15 mm, the tabulated values are applicable for Mediterranean and North Sea conditions (3 %). 4 Structures in regions with only short periods of use of de-icing salts, or low quantities annually, the minimum cover may be reduced by 10 mm, in agreement with provisions valid in the place of use. 5 The tabulated values for minimum cover assume curing class 2 according to EN (curing to 35% of f ck), where curing to curing class 3 or more is specified the cover may be reduced by 5 mm in exposure classes XC3, XC4, XD1, XD2, XD3 and XS1. 6 Concrete RXSD75 is not considered applicable for structures with 100 years design working life in exposure classes XD2, XD3, XS2 an d XS3 due to excessive cover requirements. 19
20 DtS values compared to minimum cover Tentative - Preliminary values Cement type or equivalent binder combination CEM I CEM II-A CEM II-B CEM III-A CEM III-B Carbonation resistance class RXC Chloride resistance class RXSD Frost resistance class RXF RXC20 RXC30 RXC40 RXSD45 RXSD60 RXSD75 RXF0,2 RXF0,5 RXF1,0 Maximum w/b-ratio b is the sum of cement and additions in the concrete, within the limits defining the cements according to EN ,55 0,60 0,65 NA NA 0,45 1 0,40 0,45 0,50 0,45 0,55 0,65 0,40 0,50 0,60??? 0,40 0,50 0,60 0,40 0,50 0,60??? NA 0,45 0,55?????? NA NA 0,45 0,38 0,45 0,55??? Minimum binder content (kg/m 3 ) Minimum air entrainment Preliminary 4% 4% - 1 CEM I shall only be used with minimum 4% silica values fume NA means that no deemed to satisfy values are given for that combination of binder and resistance class Exposure Class EC Sammenligning overdekning i mm Eksponeringsklasse RXC30 M60 XC XC XC XC RXSD60 M40 (M45) XD (M45) XS (M45) XD XS XD XS Minimum cover for 50 and 100 years design working life, (preliminary values, values are rounded to nearest 5 mm) RXC20 2 RXC30 2 RXC years 100-years 50-years 100-years 50-years 100-years XC XC XC XC RXSD45 RXSD60 RXSD75 6 XD XS XD NA XS NA XD NA XS NA
21 The durability concept is easy to apply for all parties involved; Exposure classes Exposure resistance classes Design working life Minimum concrete cover The designer will in the execution specification specify; Strength class, Exposure resistance class, chloride class, D upper /D lower and nominal cover as well as the Execution Class e.g C30/37 RXC30 Cl 0,20 D upper 32 D lower 16 c nom 30 mm (20+10) EXC3 The contractor will in the concrete specification specify; Strength class, Exposure resistance class, chloride class, consistence class, segregation resistance class etc. e.g C30/37 RXC30 Cl 0,20 D upper 32 D lower 16 S4 SR1 etc. The concrete producer produce and deliver a conforming concrete C30/37 RXC30 Cl 0,20 D upper 32 D lower 16 S4 SR1 21
22 91-days strength New cements and new bindercombinattions that reduces CO2- footprint Seems to give a slower strength development, a major part of the final strength comes after 28- days. 22
23 Present draft EC Strength (1) The compressive strength of concrete shall be denoted by concrete strength classes which relate to the characteristic (5%) cylinder strength f ck of the concrete in accordance with EN 206, determined at an age t ref. (2) The value for t ref should be taken as: (i) 28 days in general (ii) or may be taken between 28 and 91 days when specified for a project. Should be default, to become used and have effect on CO 2 23
24 EN 206 deals with re-cycled aggregates, but not from a design perspective, designers concern is within what limits of - Aggregate type (EN 12620) - Aggregate quantity (% replacement coarse and fine) - Intended concrete strength (upper limit) are design parameters used in EC2 unaffected? Within this range use of RA should be open for the Ready-mix producer Annex N (normative): Recycled aggregates concrete structures (1) Concrete with recycled aggregates may be used where the use of recycled aggregates will not impair durability, service performance like appearance or wear, or represent a risk of polluting water or air. Recycled aggregates may be used in normal concrete production without any particular consent if done in accordance with the provisions of EN 206. Note: The National Annex or the project specification can give further provisions and restrictions for the use of recycled aggregates for concrete. (7) For concrete of strength Class C30 and lower, recycled aggregates may be used in New clause and table regarding recycled aggregates. accordance with the parameters in Table 3.2. For higher strength classes or for higher Systematic review DK07 replacement values of the coarse fraction, including (2) replacement If the properties up to 10% listed of the in fines 5.1.2(3) for concrete with recycled aggregates are relevant for fraction, the design provisions of this standard may the be design applied in provided accordance it is demonstrated with this standard, by they should be determined by testing in tests that all values derived as a function of fck are accordance in accordance with with the the tests values specified given in Table in EN 206. The exposure resistance class should be 3.1. The procedure for testing and approval shall determined be given in the based execution on durability specification. performance testing. Table 3.2: Maximum fraction of recycled coarse aggregates (4/32) in strength class C30 and lower, for exposure resistance classes documented (3) All other by deemed clauses to of satisfy this standard values in are generally applicable, unless they are substituted by EN special provisions given in Table N.1. Recycled aggregates (4/32) Type according to EN RX0 RC40 RC30 RC20 RSD Type A 30% 30% 30% 20% 0 Type B 30% 30% 20% 0% 1 Where the resistance class is documented by tests with the actual recycled aggregates the maximum value may be taken as 30%. 24
25 The report express concern for creep, shrinkage and E- modulus, but also for normal density concrete there is a variation of +/- 30% There is also concern for shear, since failure mode can differ, but capacities are not lower than the reference. 25
26 The Goal is there Thank you for your attention
POZZOLANIC CEMENT Fly ash based (CEM IV/B-V 32,5N) Properties & Applications
PROPERTIES & APPLICATIONS POZZOLANIC PAGE 1 OF 7 Uniclass L621 CI/SfB March 2014 Yq2 POZZOLANIC CEMENT Fly ash based (CEM IV/B-V 32,5N) Properties & Applications PROPERTIES & APPLICATIONS CEMENT PROPERTIES
More informationEnvironmental exposure classifications for concrete construction A relook
Environmental exposure s for concrete construction A relook Saravanan Ramalingam and Manu Santhanam Durability of concrete structures is dependent on the design mix used (i.e. ratio and quality of ingredients
More informationStrength classes for concrete
12 15 20 1.6 1.1 2.0 27 1.8 16 20 24 1.9 1.3 2.5 29 1.9 20 25 28 2.2 1.5 2.9 30 2.0 Strength classes for concrete 25 30 33 2.6 1.8 3.3 31 2.1 30 37 38 2.9 2.0 3.8 33 2.2 3.5 2.0 3.5 2.0 1.75 3.5 35 45
More informationA-4 TEST DATA FOR MATERIALS v) Cement used : OPC 43 grade confirming to IS 8112 w) Specific gravity of cement : 3.15 x) Specific gravity of
A-2 SELECTION OF WATER CEMENT RATIO From Table 5 of IS:456-2000, maximum water cement ratio = 0.50 (Moderate exposure) Based on experience adopt water cement ratio as 0.45 as the cement is 53 grade 0.45
More informationChapter VI Mix Design of Concrete
CIV415 CONCRETE TECHNOLOGY Chapter VI Mix Design of Concrete Assist.Prof.Dr. Mert Yücel YARDIMCI Advanced Concrete Technology - Zongjun Li 1 Mix Design Mix design can be defined as the processes of selecting
More informationDurability of Post-Tensioning: fib Bulletin 33 and FHWA Scan tour Findings. Presented by Brett Pielstick P.E., F.ASCE
Durability of Post-Tensioning: fib Bulletin 33 and FHWA Scan tour Findings Presented by Brett Pielstick P.E., F.ASCE 1 Introduction Early Durability Issues Assessment Concrete Society TR-47 FHWA Scan Tour
More informationThe Effect of Different Exposure Conditions on the Chloride Diffusion into Concrete in the Persian Gulf Region
The Effect of Different Exposure Conditions on the Chloride Diffusion into Concrete in the Persian Gulf Region P. Ghods, M. Chini, R. Alizadeh, M. Hoseini, Graduate Research Assistants, Civil Engg. Dept.,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 16204 First edition 2012-09-01 Durability Service life design of concrete structures Durabilité Conception de la durée de vie des structures en béton Reference number ISO 16204:2012(E)
More informationFundamentals of Concrete
Components Cement Water Fine Aggregate Coarse Aggregate Fundamentals of Range in Proportions Advantages of Reducing Water Content: Increased strength Lower permeability Fundamentals of Increased resistance
More informationESTIMATION OF CONCRETE SERVICE LIFE The Theoretical Background
ESTIMATION OF CONCRETE SERVICE LIFE The Theoretical Background by Vagelis G. Papadakis Chemical Engineer, PhD Patras, Greece, 2005 Estimation of concrete service life ESTIMATION OF CONCRETE SERVICE LIFE
More informationTechnical Manual Section 17 Self-Compacting Lightweight Aggregate Concrete
Uniclass L331:P224 CI/SfB (-A) Eq7 EPIC C311:X223 Technical Manual Section 17 Self-Compacting Lightweight Aggregate Concrete General Design Guidance 2 Workability 2 Water content 2 Placing and compacting
More informationENGINEERING MATERIALS Assignment #8: Concrete Mix Design
14.310 ENGINEERING MATERIALS Assignment #8: Concrete Mix Design PROBLEM #1: GIVEN: Concrete is required for a pavement slab that will be exposed to severe freeze-thaw climate as well as deicing chemicals.
More informationSvein E. Haagenrud and Guri Krigsvoll. Instructions for quantitative classification of environmental degradation loads onto structures
Svein E. Haagenrud and Guri Krigsvoll Instructions for quantitative classification of environmental degradation loads onto structures 378 Project report 2004 Project report 378 Svein Haagenrud and Guri
More informationUtilization of micro silica as partial replacement of OPC & SRC in concrete
International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 3, Issue 3(March 2014), PP.67-73 Utilization of micro silica as partial replacement of
More information3/5/2014. Disclaimer and Waiver of Liability. Portland Cement Association. Learning Objectives. Why do concrete problems occur?
Disclaimer and Waiver of Liability T-20 Troubleshooting Concrete Mix Designs and Specifications Michelle L. Wilson, FACI Director, Education Portland Cement Association www.cement.org Tuesday, March 4,
More informationNRMCA is working on. Experimental Case Study Demonstrates Advantages of Performance Specifications
Experimental Case Study Demonstrates Advantages of Performance Specifications By Karthik Obla, Director of Research and Materials Engineering Fernando Rodriguez, Laboratory Manager and Soliman Ben Barka,
More informationDurability Predictions Using Early-Age Durability Index Testing
Durability Predictions Using Early-Age Durability Index Testing JR Mackechnie & MG Alexander Summary: Durability of reinforced concrete structures is often dependent on the corrosion of reinforcement due
More informationEnvironmental Engineering Concrete Structures - Introduction. William A. Wallace, P.E., SECB
Environmental Engineering Concrete Structures - Introduction William A. Wallace, P.E., SECB Topics Define environmental concrete structure Pictorial examples Historical stroll down memory lane (NRCS based)
More informationREQUIREMENTS FOR CONCRETE MIX DESIGN
REQUIREMENTS FOR CONCRETE MIX DESIGN Requirements of concrete mix design should be known before calculations for concrete mix. Mix design is done in the laboratory and samples from each mix designed is
More informationProperties of concrete with Ground Granulated Blast Furnace Slag. Effect of the addition on the frost scaling resistance and chloride migration
Properties of concrete with Ground Granulated Blast Furnace Slag. Effect of the addition on the frost scaling resistance and chloride migration Master Degree in Civil Engineering Técnico Lisboa, Universidade
More informationDURABILITY AND SERVICEABILITY
DURABILITY AND SERVICEABILITY Introduction of Durability Durability requirements are to ensure that a structure has satisfactory durability and serviceability performance under normal circumstances throughout
More informationA STUDY ON LONG-TERM PERFORMANCE OF CONCRETE OVER 50 MPa IN COMPRESSIVE STRENGTH
A STUDY ON LONG-TERM PERFORMANCE OF CONCRETE OVER 50 MPa IN COMPRESSIVE STRENGTH A DISSERTATION Submitted to Kyushu University in partial fulfillment of the requirements for the degree of Doctor of Engineering
More informationCONSIDERATIONS ON THE THRESHOLD CHLORIDE CONTENT VALUES ON THE CORROSION OF STEEL BARS IN CONCRETE
CONSIDERATIONS ON THE THRESHOLD CHLORIDE CONTENT VALUES ON THE CORROSION OF STEEL BARS IN CONCRETE N.Otsuki*, Tokyo Institute of Technology, Japan T. Nishida, Tokyo Institute of Technology, Japan M. Madlangbayan,
More informationEuropean Standard En 1504
BS EN 1504 Products and Systems for the protection and repair of concrete structures Definitions, requirements, quality control and evaluation of conformity John Drewett Concrete Repairs Ltd 25% of the
More informationTotal 30. Chapter 7 HARDENED CONCRETE
Total 30 Chapter 7 HARDENED CONCRETE 1 Shrinkage Shrinkage of concrete is caused by the settlement of solids and the loss of free water from the plastic concrete (plastic shrinkage), by the chemical combination
More informationHow to calculate anchorage and lap lengths to Eurocode 2
How to calculate anchorage and lap lengths to Eurocode 2 This is the first in a series of articles, previously printed in The Structural Engineer magazine, which will be collated to form a Concrete Structures
More informationUSE OF DURABILITY-RELATED TESTS FOR QUALITY CONTROL: VARIABILITY OBTAINED IN A REAL CASE
USE OF DURABILITY-RELATED TESTS FOR QUALITY CONTROL: VARIABILITY OBTAINED IN A REAL CASE Bettencourt Ribeiro and Arlindo Gonçalves LNEC, National Laboratory of Civil Engineering, Portugal Abstract The
More informationProperties of Concrete with GGBS and its Applications for Bridge Superstructures
Properties of Concrete with GGBS and its Applications for Bridge Superstructures Yasutaka SAGAWA 1*, Daisuke Yamamoto 1 and Yoshikazu HENZAN 2 1 Kyushu University, Japan 2 P.S. Mitsubishi Construction
More informationCharacterization of TX Active Cement
Characterization of TX Active Cement Brett Trautman Field Materials Eng. Two-Lift Paving Open House Route 141, St. Louis County September 28, 2010 History Late 2008, Director heard a presentation on Green
More informationA BRIEF STATE-OF-THE-ART REVIEW OF PNEUMATICALLY APPLIED CONCRETE OR MORTAR (SHOTCRETE)
183 A BRIEF STATE-OF-THE-ART REVIEW OF PNEUMATICALLY APPLIED CONCRETE OR MORTAR (SHOTCRETE) Marvin H. Hilt()n Senior Research Scientist Virginia Transportati()n Research C()uncil (A Co()perative Organizati()n
More informationDrying Shrinkage of "Norwegian" Self-Compacting Concrete
1 Drying Shrinkage of "Norwegian" Self-Compacting Concrete Kåre Johansen MSc Eng., Research Engineer, E-mail: Kare.Johansen@civil.sintef.no Tor Arne Hammer MSc Eng., Research Engineer, E-mail: Tor.Hammer@civil.sintef.no
More informationMETHOD OF TEST FOR CEMENT CONTENT FOR PORTLAND CEMENT CONCRETE PAVEMENTS
STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF TRANSPORTATION DIVISION OF ENGINEERING SERVICES Transportation Laboratory 5900 Folsom Blvd. Sacramento, California 95819-4612
More informationMOVING TOWARDS MODEL SPECIFICATION GUIDELINES FOR THE SUPPLY OF READYMIXED CONCRETE IN NEW ZEALAND JAMES MACKECHNIE ALLIED CONCRETE
MOVING TOWARDS MODEL SPECIFICATION GUIDELINES FOR THE SUPPLY OF READYMIXED CONCRETE IN NEW ZEALAND JAMES MACKECHNIE ALLIED CONCRETE ABSTRACT Specifications for the supply of concrete to construction projects
More informationSERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS
MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 1 THE SPECIFICATION FOR HIGHWAY WORKS SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS Contents Clause Title Page 1100 (02/17) General 2 #1101 Precast Concrete
More informationCIMENT FONDU. Special cement for concrete and mortar solutions
Special cement for concrete and mortar solutions >> Rapid return to service Rapid hardening: more than 25 MPa in 6 hours Ciment Fondu mortars and concretes are very rapid hardening, with a setting time
More informationDURABILITY of CONCRETE STRUCTURES. Part- 3 Concrete Cracks
DURABILITY of CONCRETE STRUCTURES Assist. Prof. Dr. Mert Yücel YARDIMCI Part- 3 Concrete Cracks This presentation covers the subjects in CEB Durable Concrete Structures Guideline and has been prepared
More informationPERFORMANCE-BASED DESIGN OF CONCRETE STRUCTURES
PERFORMANCE-BASED DESIGN OF CONCRETE STRUCTURES - JSCE STANDARD SPECIFICATIONS FOR CONCRETE STRUCTURES ON STRUCTURAL PERFORMANCE VERIFICATION - Hiroshi YOKOTA 1 SUMMARY The worldwide trend for structural
More informationMETHOD OF TEST FOR EVALUATION OF SUPERPLASTICIZING ADMIXTURES FOR CONCRETE
Laboratory Testing Manual Date: 02 07 01 Page 1 of 7 METHOD OF TEST FOR EVALUATION OF SUPERPLASTICIZING ADMIXTURES FOR CONCRETE 1. SCOPE This method covers physical requirements and qualification tests
More informationCHAPTER 7: SERVICEABILITY LIMIT STATES
CHAPTER 7: SERVICEABILITY LIMIT STATES 7.1 GENERAL It shall be in accordance with JSCE Standard Specification (Design), 7.1. 7.2 CALCULATION OF STRESS AND STRAIN It shall be in accordance with JSCE Standard
More informationfib publications - Pr.November 2017:
fib publications - Pr.November 2017: No. 79. Fibre-reinforced concrete: From design to structural applications. FRC 2014: ACI-fib International Workshop Proceedings - ACI SP-310 (480 pages, ISBN 978-2-88394-119-9,
More informationProperties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete. Properties of Concrete
CIVL 1112 Contrete Introduction from CIVL 1101 1/10 Concrete is an artificial conglomerate stone made essentially of Portland cement, water, and aggregates. While cement in one form or another has been
More informationCourse Concrete Technology Course Code Theory Term Work POE Total Max. Marks Contact Hours/ week
Course Concrete Technology Course Code 43588 Examination Scheme Theory Term Work POE Total Max. Marks 100 50 -- 150 Contact Hours/ week 3 2 -- 5 Prepared by Mr. C.S. Patil / Mr. S.P. Patil Date Prerequisites
More informationEfficiency of CFBC fly ash. material in structural concrete
INSTITUTE OF FUNDMENTAL TECHNOLOGICAL RESEARCH POLISH ACADEMY OF SCIENCES WARSZAWA, POLAND Michal A. Glinicki Efficiency of CFBC fly ash as secondary cementitious material in structural concrete Anna Maria
More informationCarbonation Testing Of Hardened Concrete And The Effect Of Cement Type
Carbonation Testing Of Hardened Concrete And The Effect Of Cement Type MR Jones MD Newlands & AMO Abbas Concrete Technology University of Dundee Scotland UK Summary: Carbonation-induced corrosion affects
More informationMECHANICAL PROPERTIES AND DURABILITY OF HIGH PERFORMANCE PROTECRETE CONCRETE
MECHANICAL PROPERTIES AND DURABILITY OF HIGH PERFORMANCE PROTECRETE CONCRETE Mohsen A. Issa*, David T. Johnson **, Mahmoud A. Issa*, Mohamad Faraj*, Robert L. Bickers** *Dept. of Civil and Materials Eng..
More informationEuropean Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the
European Technical Assessment General Part of 29/12/2017 (English language translation the original version is in Polish language) Body issuing the European Trade name of the construction product Product
More informationExperimental research for the determination of some parameters needed for the calculation of life-cycle CO 2 emission of reinforced concrete buildings
Experimental research for the determination of some parameters needed for the calculation of life-cycle CO 2 emission of reinforced concrete buildings Dan Paul GEORGESCU, Adelina APOSTU, Radu PASCU Reinforced
More information100-YEAR SERVICE-LIFE BRIDGE DECKS USING LOW-SHRINKAGE HIGH-PERFORMANCE CONCRETE
100-YEAR SERVICE-LIFE BRIDGE DECKS USING LOW-SHRINKAGE HIGH-PERFORMANCE CONCRETE Daniel Cusson, Ph.D., P.Eng. National Research Council Canada, Ottawa, Ontario, Canada Abstract: Highway bridges and parking
More informationFlexure Design Sequence
Prestressed Concrete Beam Design Workshop Load and Resistance Factor Design Flexure Design Flexure Design Sequence Determine Effective flange width Determine maximum tensile beam stresses (without prestress)
More informationExperimental investigation of the use of CFRP grid for shear strengthening of RC beams
Journal of Asian Concrete Federation Vol. 2, No. 2, Dec. 2016, pp. 117-127 ISSN 2465-7964 / eissn 2465-7972 http://dx.doi.org/10.18702/acf.2016.12.2.2.117 Experimental investigation of the use of CFRP
More information3/4/2015 COLD WEATHER CONCRETE PRACTICES SUCCESSFUL COLD WEATHER CONCRETING
COLD WEATHER CONCRETE PRACTICES CRMCA SOUTHERN MARKETING O SUCCESSFUL COLD WEATHER CONCRETING 1 2 3 ACI DEFINITION OF COLD WEATHER Cold Weather - A period when, for more than 3 consecutive days, the following
More informationEarly Thermal Cracking of Concrete
THE HIGHWAYS AGENCY THE SCOTTISH OFFICE DEVELOPMENT DEPARTMENT Incorporating Amendment No.1, 1989 THE WELSH OFFICE Y SWYDDFA GYMREIG THE DEPARTMENT OF THE ENVIRONMENT FOR NORTHERN IRELAND Early Thermal
More informationSHEAR BEHAVIOR OF RC BEAMS USING U-SHAPED UFC PERMANENT FORMWORK WITH SHEAR KEYS OR BOLTS
- Technical Paper - SHEAR BEHAVIOR OF BEAMS USING U-SHAPED PERMANENT FORMWORK WITH SHEAR KEYS OR BOLTS Puvanai WIROJJANAPIROM *1, Koji MATSUMOTO *2, Katsuya KONO *3 and Junichiro NIWA *4 ABSTRACT Shear
More informationmortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE
SECTION 1. mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE 1.1 Overview of AS 3600:2009 AS 3600:2009 is the latest Australian
More informationMaterial Requirements for Steel and Concrete Structures
Material Requirements for Steel and Concrete Structures Chiew Sing-Ping School of Civil and Environmental Engineering Nanyang Technological University, Singapore Materials Concrete Reinforcing steel Structural
More informationTolerances- Section
Tolerances- Section 346-6.4 Do not add water to delivered concrete when it is within the target Range for slump 1 346-6.4 Tolerances: Meet the following tolerances from target values for plastic concrete
More informationETAG 018 FIRE PROTECTIVE PRODUCTS PART 2: REACTIVE COATINGS FOR FIRE PROTECTION OF STEEL ELEMENTS
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition June 2006 GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL
More informationTECHNICAL SPECIFICATION FOR PRESTRESSED CEMENT CONCRETE POLES ( F.O.S. 2.5) FOR 11 KV AND LT LINES ( REC SPECIFICATION NO.
TECHNICAL SPECIFICATION FOR PRESTRESSED CEMENT CONCRETE POLES ( F.O.S. 2.5) FOR 11 KV AND LT LINES ( REC SPECIFICATION NO. 15 / 1979) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7
More informationCOMPARISON ON THE DURABILITY OF DIFFERENT PORTLAND CEMENTS AFTER FIVE YEARS EXPOSURE TO SULFATE AND TO SEA WATER ATTACK
COMPARISON ON THE DURABILITY OF DIFFERENT PORTLAND CEMENTS AFTER FIVE YEARS EXPOSURE TO SULFATE AND TO SEA WATER ATTACK 1 López-Sánchez P 1 INTEMAC (Department of Chemical and Materials Technology) Madrid.
More informationSeismic Analysis of Concrete Dams Workshop USSD Annual Conference April 6-7, 2017
Workshop 2017 USSD Annual Conference April 6-7, 2017 Seismic Analysis of Concrete Dams Selection of analysis Selection of Materials Properties Properties affected by state of the art for materials, mix
More informationWe have great ideas for construction sites
We have great ideas for construction sites For Betonrossi success is the result of ideas developed through intuition, experience, research and technology. Great ideas for the construction world and even
More informationConcrete. Chapter 10 Properties of Fresh Concrete. Materials of Construction-Concrete 1. Wikipedia.org
Wikipedia.org Concrete Chapter 10 Properties of Fresh Concrete Materials of Construction-Concrete 1 What is Concrete? Concrete is a composite material that consists of a cement paste within which various
More informationFly Ash Route to Low Embodied CO 2 and Implications for Concrete Construction
2011 World of Coal Ash (WOCA) Conference May 9-12, 2011 in Denver, CO, USA http://www.flyash.info/ Fly Ash Route to Low Embodied CO 2 and Implications for Concrete Construction Rod Jones, Michael McCarthy
More informationADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode
ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode Update: August 2016 Copyright ADAPT Corporation all rights reserved ADAPT-PT/RC 2016-Tutorial- 1 This ADAPT-PTRC 2016 Getting Started Tutorial is
More informationMix Design For Concrete Roads As Per IRC:
Mix Design For Concrete Roads As Per IRC:15-2011 ABSTRACT: The stresses induced in concrete pavements are mainly flexural. Therefore flexural strength is more often specified than compressive strength
More informationOUTCOMES OF 3-YEAR CONCRETE FOLLOW UP FOR THE LUSAIL RAIL TRANSIT SYSTEM IN DOHA (QATAR)
OUTCOMES OF 3-YEAR CONCRETE FOLLOW UP FOR THE LUSAIL RAIL TRANSIT SYSTEM IN DOHA (QATAR) Lionel LINGER, Laurent BOUTILLON VINCI Construction Grands Projets, 5 cours Ferdinand de Lesseps, 92851 Rueil-Malmaison
More informationHIGH PERFORMANCE CONCRETE - HPC
HIGH PERFORMANCE CONCRETE - HPC Fahim Al-Neshawy & Esko Sistonen 23.10.2015 Outlines Introduction Materials used in HPC Methods used for making HPC HPC - mix design Properties of HPC Advantages and disadvantages
More informationA. HIGH-STRENGTH CONCRETE (HSC)
EFFECTS OF SILICA FUME ON PROPERTIES OF HIGH-STRENGTH CONCRETE Nasratullah Amarkhail Graduate School of Science and Technology, Department of Architecture and Building Engineering Kumamoto University Kumamoto
More informationCONCRETE MIX DESIGN WORKSHOP FOR NORMAL CONCRETE MIXTURES 3/21/2017 1
53 th Quality Concrete School New Mexico State University Concrete Mix Design Workshop January 13 14, 2017 CONCRETE MIX DESIGN WORKSHOP FOR NORMAL CONCRETE MIXTURES 3/21/2017 1 Mix Design is the Recipe
More informationEuropean Technical Assessment ETA-10/0422 of 08/01/2016
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011
More information5/16/2002 DRAFT TABLE OF CONTENTS
TABLE OF CONTENTS 1. Introduction. 1 2. High-Performance Concrete Defined.. 2 3. Goals 3 3.1. Engineering Guidelines and Design Aids 3 3.2. Durable Bridge Decks. 3 3.3. High Strength Bridge Girders. 4
More informationAuthor: M Shaw, Sika Limited. Construction. A Guide to the Concrete Repair European Standards BS EN 1504 Series
Author: M Shaw, Sika Limited A Guide to the Concrete Repair European Standards BS EN 1504 Series 1 Contents Section Heading Page Introduction 3 1.0 Overview of BS EN 1504 Documents 4 2.0 BS EN 1504 Principles
More informationTailor-made concrete structures Case studies from projects worldwide
Tailor Made Concrete Structures Walraven & Stoelhorst (eds) 2008 Taylor & Francis Group, London, ISBN 978-0-415-47535-8 Tailor-made concrete structures Case studies from projects worldwide C.K. Edvardsen
More informationPRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)
CI/SfB Yu2 Kryton International Inc 1645 East Kent Avenue Vancouver British Columbia Canada V5P 2S8 Tel: 00 1 604 324 8280 Fax: 00 1 604 324 8899 e-mail: info@kryton.com website: www.kryton.com Agrément
More informationEvaluation of unbound crushed concrete as road building material Mechanical properties vs field performance
Evaluation of unbound crushed concrete as road building material Mechanical properties vs field performance Corresponding author: Joralf Aurstad Norwegian Public Roads Administration, Trondheim, Norway
More informationWould You Like Concrete With Little or No Shrinkage, Cracking, and Curling??? We Will Focus on:
Would You Like Concrete With Little or No Shrinkage, Cracking, and Curling??? We Will Focus on: Coarse Aggregates Admixtures Including Shrinkage Reducing and Shrinkage Compensating Admixtures Evaporation
More informationIntroductory Chapter
Introductory Chapter Asian Concrete Model Code 2014, Introductory Chapter TABLE OF CONTENTS DEFINITIONS...3 1 INTRODUCTION... 8 1.1 SCOPE... 8 1.2 DOCUMENT ORGANISATION... 8 1.3 GENERAL PRINCIPLES... 8
More informationEurocode 6 Design of masonry structures
BRITISH STANDARD BS EN 1996-2:2006 Incorporating corrigendum September 2009 Eurocode 6 Design of masonry structures Part 2: Design considerations, selection of materials and execution of masonry ICS 91.010.30;
More informationREPORT STATUS: DATE: Report n :
REPORT: Expanded clay LWA in CEA Lightweight fill and thermal insulation products for civil engineering applications. Installation and structural quality control on site. STATUS: Technical report DATE:
More informationProtecting Concrete. Solutions to Extend the Life of Your Structure
Protecting Concrete Solutions to Extend the Life of Your Structure 2 Protecting Concrete Contents 03 _ Master Builders Solutions from BASF 04 _ Repair and protection systems 05 _ Extending the life cycle
More informationTechnical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board
Member of Kiwa Nederland B.V. www.eota.eu Sir Winston Churchilllaan 273 NL-2288 EA Rijswijk Postbus 70 NL-2280 AB Rijswijk Tel.: +31 (0)88 998 44 00 Fax: +31 (0)88 998 44 20 E-mail: info@kiwa.nl European
More informationXYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF
Xypex (UK) LLP Unit 7 Britannia Business Centre Britannia Way Malvern Worcestershire WR14 1GZ Tel: 01684 577756 Fax: 01684 897750 e-mail: adamtrow@xypexuk.com website: www.xypex.com APPROVAL INSPECTION
More informationChemical Admixtures for Concrete. ACCELERATORS Özge Andiç Çakır, PhD
Chemical Admixtures for Concrete ACCELERATORS Özge Andiç Çakır, PhD Accelerators: Definition An accelerating admixture is a material that is added to concrete for reducing the time of setting and accelerating
More informationD DAVID PUBLISHING. Damaging Formula of the Frost Resistant Concrete with Poor Quality of Coarse Limestone Aggregate. 1.
Journal of Civil Engineering and Architecture 9 (2015) 598-603 doi: 10.17265/1934-7359/2015.05.012 D DAVID PUBLISHING Damaging Formula of the Frost Resistant Concrete with Poor Quality of Coarse Eneli
More informationPumice Pozz vs. Fly Ash
Pumice Pozz vs. Fly Ash Extensive ASTM-standard Research Quantifies Pumice as the Ideal Replacement for Fly Ash in Concrete IN EACH AND EVERY ONE of the concrete performance categories that matter, clean,
More informationVDOT s New High Performance Concrete Specifications
VDOT s New High Performance Concrete Specifications Celik Ozyildirim, Ph.D., P.E. A partnership of the Virginia Department of Transportation and the University of Virginia since 1948 3/4/2010 1 HPC in
More informationStrength related global warming potential of fly ash (+ silica fume) concrete with(out) mass/economic allocation of the by-products impact
Strength related global warming potential of fly ash (+ silica fume) concrete with(out) mass/economic allocation of the by-products impact P. Van den Heede (1) and N. De Belie (1) (1) Magnel Laboratory
More informationEN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)
42.50 10.00 3.00 20.00 EN 1996-1-1 REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES) Reinforced Masonry - Reinforced Brickwork Stem Cantilever Pocket-Type Retaining
More informationHanson Multicem is manufactured to comply with the requirements of BS EN CEM II/A-LL (Portlandlimestone cement) strength class 32,5R.
Hanson Multicem technical Data Sheet Hanson Multicem is manufactured to comply with the requirements of BS EN 197-1 CEM II/A-LL (Portlandlimestone cement) strength class 32,5R. Multicem incorporates a
More informationEN Fire design of concrete structures
Brussels, 18-20 February 2008 Dissemination of information workshop 1 EN 1992-1-2 Fire design of concrete structures Tauno Hietanen Finnish Concrete Industry Association convenor of Project Teams - ENV
More informationComparison of Properties of Fresh and Hardened Concrete Containing Finely Ground Glass Powder, Fly Ash, or Silica Fume
Article Comparison of Properties of Fresh and Hardened Concrete Containing Finely Ground Glass Powder, Fly Ash, or Silica Fume Rungrawee Wattanapornprom a, and Boonchai Stitmannaithum b Faculty of Engineering,
More informationLecture Notes. Elasticity, Shrinkage and Creep. Concrete Technology
Lecture Notes Elasticity, Shrinkage and Creep Concrete Technology Here the following three main types of deformations in hardened concrete subjected to external load and environment are discussed. Elastic
More informationDESIGN OF NORMAL CONCRETE MIXES
DESIGN OF NORMAL CONCRETE MIXES SECOND EDITION D C Teychenné, R E Franklin, H C Erntroy, D W Hobbs, B K Marsh DESIGN OF NORMAL CONCRETE MIXES Second edition D C Teychenné, BSc(Eng), MIStructE R E Franklin,
More informationDESIGN GUIDELINES Partial safety factors for strengthening of metallic structures. Dr. Stuart Moy University of Southampton
DESIGN GUIDELINES Partial safety factors for strengthening of metallic structures Dr. Stuart Moy University of Southampton Contents 1. Some examples of strengthening 2. Metallic structures 3. Why are Design
More informationEuropean Technical Assessment ETA-14/0453 of 11/12/2014
ETA-Danmark A/S Göteborg Plads 1 DK-21590 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011
More informationOPTIMIZED 3/4" GRADATION LIGHTWEIGHT AGGREGATE REPORT
OPTIMIZED 3/4" GRADATION LIGHTWEIGHT AGGREGATE REPORT PREPARED BY: JODY WALL, P.E. DIRECTOR OF RESEARCH AND DEVELOPMENT CAROLINA STALITE COMPANY RESEARCH LAB GOLD HILL, NORTH CAROLINA Optimized 3/4" Gradation
More informationEffects of Materials and Mixing Procedures on Air Void Characteristics of Fresh Concrete
Effects of Materials and Mixing Procedures on Air Void Characteristics of Fresh Concrete Shihai Zhang Civil, Construction and Environmental Engineering Iowa State University 16 Town Engineering Building
More informationPROPORTIONING CONCRETE MIXES
TOKYO INSTITUTE OF TECHNOLOGY Department of Civil Engineering ATCE ADVANCED TOPICS IN CIVIL ENGINEERING Professor Kamran M. Nemati PROPORTIONING CONCRETE MIXES ATCE Advanced topics in Civil Engineering
More informationMix Design For Concrete Roads As Per IRC
Mix Design For Concrete Roads As Per IRC-15-2002 ABSTRACT: The stresses induced in concrete pavements are mainly flexural. Therefore flexural strength is more often specified than compressive strength
More information