Ultra-High Performance Wall System Glass Fiber Reinforced Concrete

Size: px
Start display at page:

Download "Ultra-High Performance Wall System Glass Fiber Reinforced Concrete"

Transcription

1 Ultra-High Performance Wall System Glass Fiber Reinforced Concrete We are your wall one system, one supplier, one warranty. Our Ultra-High Performance Wall System (UHPWS) is a prefabricated unitized wall system that combines Glass Fiber Reinforced Concrete (GFRC), Schüco windows, mineral wool insulation and a sealed back pan into one integrated system. These wall systems are manufactured in our Orlando factory and are shipped to the jobsite as a finished wall.

2 Description GFRC is a lightweight, impact resistant masonry cladding system made of galvanized steel framing and a GFRC skin of minimum 3/4 thickness. The GFRC skin is mechanically connected to galvanized steel framing with flexible anchors that allow for differential movement between the two components. GFRC skin is made using Portland cement, sand, aggregate and alkali resistant glass fiber that has excellent flexural strength and impact resistance properties. Skin materials are sprayed by thin layers into molds. This makes GFRC highly effective at capturing complex geometries, deep returns and intricate ornamentation. Molds are usually produced with 5-axis CNC technology to maintain tight fabrication tolerances and efficiencies. Building Blocks works with architects and engineers in a digital design process that employs Revit, Rhino, and Grasshopper. GFRC skin with galvanized steel framing ThermaFiber insultation and insulating tape 18-gauge sheet metal backpan with sealant Once the GFRC component of the wall system is completed, the window is set and anchored to the GFRC framing. A two-stage sealant joint is then applied to the interface between the window and the GFRC. Building Blocks uses Schüco windows, which are German engineered and locally fabricated. They bring performance, reliability and durability to the fenestrations of our wall system. The cavity space of the wall system is packed with either Thermafiber CW-90 mineral wool insulation or Thermafiber SAFB, for acoustical applications. Thermal insulating tape is applied to the backside of the framing as a thermal break. 18-gauge sheet metal is screwed to the framing. Sealant is applied to all penetrations through the back pan. The panels are hand finished and then shipped. The total system weighs between 12 to 22 lbs per SF based on the window to wall ratio.

3 Application Panels of GFRC can be as large as 11-6 by 38-0 for a total surface area of 440 square feet. Panels are shipped to the jobsite on a flatbed truck. A typical load contains 1,500 to 2,500 square feet of material. Panels are erected with either a ground crane or tower crane at a rate of 1,500 to 2,000 square feet per day. GFRC cladding is typically designed as horizontal panels that span floor to floor with gravity connections on one floor and lateral connections on the opposite floor. Panels can span multiple floor heights when the design allows vertical panels. Gravity connections are relatively lightweight due to the weight efficiency of GFRC with typical loads of 1,500 lbs per connection. FIRE SAFING OMITTED FOR CLARITY SEE DETAIL 1 FOR ADDITIONAL NOTES BLOCK OUT BOX PROVIDED AT CONNECTION POINTS FIELD FILL POCKETS AFTER ALIGNMENT 4" CW40 MINERAL WOOL INSULATION FACTORY INSTALLED 20GA AIR/VAPOR BARRIER FACTORY INSTALLED 20GA AIR/VAPOR BARRIER FIELD INSTALLED OVER 3M VR TAPE INTERIOR FINISH BY OTHERS SMOKE SEAL 2" MINERAL WOOL INSULATION 4" DEEP MIN 8" FLOOR SLAB 4" CW40 MINERAL WOOL INSULATION FACTORY INSTALLED 20GA AIR/VAPOR BARRIER FACTORY INSTALLED 20GA AIR/VAPOR BARRIER FIELD INSTALLED OVER 3M VR TAPE INTERIOR FINISH BY OTHERS

4 Finishes GFRC can be produced in a wide variety of colors, textures and patterns. Colors are achieved from a combination of through-body pigmentation, aggregates, surface stains and coatings. Most colors that are incorporated into the body of GFRC are synthetic mineral-oxide pigments. Naturally colored aggregates are used separately or in combination with pigments to arrive at a desired color. Bright and highly saturated colors are accomplished with masonry stains and sealers. These finishes can be made to have a matte, shiny, metallic, shimmer or glitter effect. Texture is achieved by sandblasting the surface. Sandblasting can be done with fine grade particles and lightly applied for a smooth form finish, through five progressive stages, to large particles, heavily applied for a course finish. Patterns and intricate designs are made by using a formliner set into the mold. Due to the richness of cement in the face mix, GFRC captures and retains crisp details. Flexibility in form, texture and color.

5 Performance Thermal Curtainwall Design Consulting performed a thermal modeling study of a Building Blocks prefabricated unitized wall system for a project in Blackhawk, Colorado. Testing parameters were 95-degree temperature gradient between interior and exterior with a 30% interior relative humidity. Interior dew point was calculated to be 41-degree F. The coldest interior surface of the wall modeled to 66.6-degree F. Acoustical Curtainwall Design Consulting also performed an acoustical model of a Building Blocks prefabricated unitized wall system that utilized Thermafiber Sound Attenuation Fire Blanket (SAFB) to increase the acoustical performance. The wall assembly modeled to an OITC rating of 76 and an STC rating of 93. Fire GFRC with a steel stud frame has been tested to show a 0 Flame Spread and 5 Smoke Development Index. It passes as a 2-hour fire rated wall with the addition of ½ drywall on the framing and mineral wool insulation. The National Fire Protection Agency tested a GFRC wall assembly with mineral wool at all panel joints. It passed the NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non- Load-Bearing Wall Assemblies Containing Combustible Components. Single Source Building Blocks provides a single source for your project s entire vertical envelope. We combine best in class means, methods and materials to deliver a truly Ultra-High Performance Wall System. This allows us to provide a 7 year warranty, which is extendable to 10 years with a maintenance contract.

6 Technical Data Property Test Result Air Leakage* ASTM E283 Static Air Infiltration at 6.24 PSF = 0.02 CFM/SF Static Air Exfiltration at 6.24 PSF = 0.03 CFM/SF Structural Design Performance ASTM E /-45 PSF deflection was less than L/ /-67 PSF permanent deformation was less than L/1000 Static Pressure Water Resistance* ASTM E331 Static Water Infiltration at 10.0 PSF = 0 Dynamic Pressure Water Resistance AAMA 501 Dynamic Water Infiltration at MPH = 0 Thermal Transmittance Resistance AAMA F (exterior), 75 F (interior), 30% RH = 0 condensation Glass Fiber Content ASTM C1229 Glass Fiber 5% by weight Flexural Strength ASTM C947 1,200 PSI Compressive Strength ASTM C39 10,000 PSI Coefficient of Linear Thermal Expansion ASTM E x 10-6 in/in/ºf (13.6 x 10-6 mm/mm/ C) Water Vapor Transmission Surface Burn Characteristics ASTM E96 ASTM E Perm with Mineral Wool 0.1 Perm with Closed Cell Foam Insulation 0 Flame Spread 5 Smoke Development Materials in a Tube Furnace ASTM E136 Noncombustible *Results dependent on window design Quality Assurance Building Blocks is a member of the Precast Prestressed Concrete Institute (PCI). The PCI certification process is a comprehensive quality assurance program that oversees the design, engineering, fabrication and erection of GFRC. The PCI certification program was developed and is updated by a team respresenting all industry stakeholders. The program is backed by PCI and its network of committees, research and development, education, codes and standards, programs, and relationships in the industry. Working with Building Blocks ensures the knowledge and experience necessary to deliver a premium product with a history of quality assurance since our inception in Building Blocks is a furnish and install subcontractor. We take your project from start to finish, from the design and engineering through the fabrication and installation. Our GFRC manufacturing facility is located in Orlando, Florida and ships to all states east of the continental divide.

Combustible Exterior Wall Cladding Systems: An ICC Perspective

Combustible Exterior Wall Cladding Systems: An ICC Perspective Combustible Exterior Wall Cladding Systems: An ICC Perspective The tragic Grenfell Tower fire in London brought extensive public focus on combustible exterior wall systems, often called cladding, prompting

More information

Gold Bond BRAND Gypsum Sheathing

Gold Bond BRAND Gypsum Sheathing BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section

More information

HammerStone Manufactured stone veneers for commercial & residential applications

HammerStone Manufactured stone veneers for commercial & residential applications HammerStone Manufactured stone veneers for commercial & residential applications Veneer Stone Specification Guide Section 04711: Manufactured Stone Veneer Use this specification guide for each individual

More information

ProGUARD DP The Game-changing Wall System

ProGUARD DP The Game-changing Wall System ProGUARD DP The Game-changing Wall System Arriscraft ARRIS-stack over ProGUARD DP Insulated Cement Board Panels, using Laticrete MVIS materials. PROGUARD DP INSULATED CONCRETE BOARD, manufactured by T.

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove Duo-Gard Industries Inc. 40442 Koppernick Road Canton, Michigan 48187 Phone (734) 207-9700 Fax (734) 207-7995 www.duo-gard.com SECTION 08 45 13 Structured Polycarbonate Panel Assemblies Series 3500 BPC

More information

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1. SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware

More information

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 07210 BUILDING INSULATION Display hidden notes to specifier. (Don't know how? Click Here) A. Perimeter Fire Containment Systems. B. Building Insulation for Thermal

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,

More information

Why test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results.

Why test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results. 1 Pre-Construction Phase, & the Laboratory or Field Mock-Up Building Enclosure Commissioning: Train the Trainer Iowa State University, Ames Iowa May 10 12, 2016 Presented by Fiona Aldous Why test a system

More information

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board 1. Scope 1.1 This standard defines the minimum prescriptive quality and performance requirements for Fiberreinforced Magnesium Cement Board products intended for use in buildings in North America. For

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Ultra-Thin Prestressed Precast Panel Technology

Ultra-Thin Prestressed Precast Panel Technology Ultra-Thin Prestressed Precast Panel Technology AIA/CES PROGRAM PURPOSE AltusGroup Inc. is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

Floor Insulation Underlayment Section Sound Control Matting

Floor Insulation Underlayment Section Sound Control Matting Floor Insulation Underlayment Section 09618 Sound Control Matting Part I General 1.1 Summary A. Section includes a sound control material for achieving an STC and IIC rating in excess of 50 to meet building

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1015 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 07 00

More information

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-2064 Reissued 11/2017 This report is subject to renewal 11/201. DIVISION: 07 00 00

More information

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate

More information

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS SECTION 07 44 50 FIBERGLASS REINFORCED POLYMER (FRP) PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Design, Engineering, manufacturing and erection of fiberglass reinforced panels. Delegated Design of

More information

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL 13686.00 GYPSUM BOARD 092116-1 1.1 RELATED DOCUMENTS: SECTION 092116 - GYPSUM BOARD PART 1 - GENERAL A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

ENKASONIC FLOOR UNDERLAYMENT 9110

ENKASONIC FLOOR UNDERLAYMENT 9110 ENKASONIC FLOOR UNDERLAYMENT 9110 GS1197 Section 13080 SECTION 09618 SOUND CONTROL MATTING Part I General 1.1 Summary A. Section includes a sound control material for achieving an STC and IIC rating in

More information

GFRC Architectural Cladding. Manufactured by a PCI Certified Plant

GFRC Architectural Cladding. Manufactured by a PCI Certified Plant GFRC Architectural Cladding Manufactured by a PCI Certified Plant Zoho Stone Architectural Products LLC or Zoho Stone can supply designed and engineered GFRC exterior cladding systems for institutional,

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE MANUFACTURER'S SPECIFICATIONS Section 09225 ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE ST. ASTIER NATURAL HYDRAULIC LIME PLASTER PART 1 GENERAL 1.1 Summary A. This Section includes St. Astier Natural

More information

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM ARCHITECTURAL SPECIFICATIONS MANUFACTURER: InterBlock LLC PO Box 1123, Sheboygan, WI 53082 Phone Number 920-207-7234 SECTION 03100 STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM PART 1 GENERAL 1.01 Summary

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2810 Reissued 02/2018 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 24 00 1. Use this section only for NCA projects. 2. Detail wall section, base edge, expansion and control joint conditions for each system. Show locations of

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION MANUFACTURER S GUIDE SPECIFICATIONS SECTION 04 27 23 REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 07.09.13 Carlisle and R2+ are trademarks

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-03 11 13.00 10 (May 2014) --------------------------------- Preparing Activity: USACE Superseding UFGS-03 11 13.00 10 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Magnum Board Section Digicon Information Inc. Page 1

Magnum Board Section Digicon Information Inc. Page 1 Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane

More information

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units

More information

NFPA 285 Compliant Wall Systems and Assemblies

NFPA 285 Compliant Wall Systems and Assemblies NFPA 285 Compliant Wall Systems and Assemblies 2 Solutions for Non-combustible Construction Creating non-combustible exterior wall assemblies has become increasingly challenging as building design has

More information

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam

More information

Concrete Masonry. Weights and Process. Grades & Types

Concrete Masonry. Weights and Process. Grades & Types Concrete Masonry Weights and Process Two basic weights Normal weight 40 lbs. / unit 1,200-1,800psi comp strength Lightweight 22-28 lbs. / unit 700-1,000 psi comp strength Molded with a very dry mix - 3

More information

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016. ICC-ES Evaluation Report ESR-894 Reissued April 04 This report is subject to renewal April, 0. www.icc-es.org (800) 4-87 () 99-04 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL

More information

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES SECTION 092116.23 - GYPSUM BOARD SHAFT WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

Learning Objectives. A Brief History

Learning Objectives. A Brief History Slide 1 Precast Structures and Frames Miles L. Blackman, P.E. Slide 2 Learning Objectives Discuss precast concrete characteristics, advantages and benefits, typical construction methods and construction

More information

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 TK Products A Division of Sierra Corporation TK-HYDROMAX 2001 SB DAMPPROOF COATING, TK-HYDROMAX 2002 SB FOUNDATION WATERPROOF

More information

Magnesium Oxide Wallboard

Magnesium Oxide Wallboard Magnesium Oxide Wallboard Introduction Performance Models Application Factories Installment Contact Email: raychan@jhaglobal.com dennischen@jhaglobal.com Mobile: (773)470-3288 Introduction Magnesium oxide,

More information

Fire protection, soundproofing and thermal insulation

Fire protection, soundproofing and thermal insulation ROMA INSULATION SYSTEMS Fire protection, soundproofing and thermal insulation Quick-assembly insulating panel, types FP, FV and FP Acoustic 02 ROMA quick-assembly insulating panel, types FP and FP+ Cladding

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (HORIZONTAL) for CLADDING PANELS HORIZONTAL ORIENTED SYSTEM WITH OPTIONAL VERTICAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM

More information

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond Batt Fiberglass Mineral Wool Cotton Wool Blown, Sprayed Fiberglass Spray Foam Cellulose Wool Board Polystyrene (XPS, EPS) Polyisocyanurate

More information

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2375 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3500 Reissued 01/2017 This report is subject to renewal 01/2018. DIVISION: 07 00

More information

EDGEWATER, FLORIDA JUNE 14, 2010

EDGEWATER, FLORIDA JUNE 14, 2010 SECTION 09 2400 - PORTLAND CEMENT PLASTER PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene INSTALLATION MANUAL METAL INSULATED PANELS -ROXUL -Expanded Polystyrene Insulated Metal Panels London Eco-Metal Manufacturing Inc. **Also see Eco-Metal s Handling Manual** These instructions are provided

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3340 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1993 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

COURSE OUTLINE. Course Number Course Title Credits. ARC 134 Building Construction Systems 3. Co- or Pre-requisite. none

COURSE OUTLINE. Course Number Course Title Credits. ARC 134 Building Construction Systems 3. Co- or Pre-requisite. none COURSE OUTLINE Course Number Course Title Credits ARC 134 Building Construction Systems 3 Hours: lecture/lab/other 3 / 0 Catalog description: Co- or Pre-requisite none Implementation Sem/Year Fall 2017

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

Narrow Modular Pavers (NMP) for Sand-Set Installations

Narrow Modular Pavers (NMP) for Sand-Set Installations The following specification refers to the Stepstone, Inc. product known as: Narrow Modular Pavers (NMP) for Sand-Set Installations Narrow Modular Pavers are part of the California Architectural Paver line

More information

PER See all Pei ES Listings at:

PER See all Pei ES Listings at: Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated and has a Follow-up Service

More information

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year. ESR-1015 Issued November 1, 2003 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (VERTICAL) for CLADDING PANELS VERTICAL ORIENTED SYSTEM WITH OPTIONAL HORIZONTAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM DEPTH:

More information

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016. A Subsidiary of the International Code Council DIVISION:

More information

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide. Note: This document has been divided into several sections in order to suit the limitations of the website. The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice

More information

Differences between EnCon Insulated Precast and EIFS

Differences between EnCon Insulated Precast and EIFS Differences between EnCon Cover Differences between EnCon EnCon produces a number of different insulated precast concrete products. They range from Insulated Wall panels, Styrocore Insulated Wall Panels,

More information

Cavity ShAftwall System

Cavity ShAftwall System 09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design

More information

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10530 PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

TECHNICAL GUIDE ALUMINUM COMPOSITE PANELS & INSTALLATION SYSTEMS

TECHNICAL GUIDE ALUMINUM COMPOSITE PANELS & INSTALLATION SYSTEMS TECHNICAL GUIDE ALUMINUM COMPOSITE PANELS & INSTALLATION SYSTEMS Effective January 2018 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Omega-Lite 1-3 Thermolite 4-5 Omega Foam-Ply 6-7 Omega-Ply

More information

2013 COMMERCIAL PRODUCTS

2013 COMMERCIAL PRODUCTS 2013 COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Building. Green. with Arriscraft International

Building. Green. with Arriscraft International Building Green with Arriscraft International Arriscraft products support the fundamental principles of green ma Energy Conservation Resource Re-use & Protection nagement with additional durability, design

More information

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors 2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3210 Valid: 03/15 to 03/16 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21

More information

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK.

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK. ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK www.metaldek.com DEEP-DEK 4.5 COMPOSITE DEEP-DEK 6 COMPOSITE DEEP-DEK COMPOSITE Deep-Dek Composite* is a long-span composite

More information

Concrete Faced Insulated Perimeter Wall Panels. Durability. Sustainability. Energy Efficiency. Durable Finish & Superior Insulation in One Easy Step

Concrete Faced Insulated Perimeter Wall Panels. Durability. Sustainability. Energy Efficiency. Durable Finish & Superior Insulation in One Easy Step WallGUARD Concrete Faced Insulated Perimeter Wall Panels Durability. Sustainability. Energy Efficiency. Reduce heat loss & energy costs Protect perimeters from freeze-thaw cycling Recyclable & reusable

More information