1 SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Prefinished polyester glass reinforced plastic sheets and adhered to unfinished [gypsum] [cementitous] [untreated plywood] wallboard. 1. [Aluminum] [PVC] trim. 2. [PVC Wall base.] B. Products Not Furnished or Installed under This Section: 1. Gypsum [Cementitious] substrate board. 2. Resilient Base. 1.2 RELATED SECTIONS A. Section [ ] Gypsum [Cementitious] substrate board. B. Section [ ] - Wood [Metal] Stud Framing C. Section [ ] - Painting & Transparent Finishes. D. Section [ ] - Resilient Base. 1.3 REFERENCES A. American Society for Testing and Materials: Standard Specifications (ASTM) 1. ASTM D Izod Impact Strengths (ft #/in) 2. ASTM D Water Absorption (%) 3. ASTM D Tensile Strengths (psi) & Tensile Modulus (psi) 4. ASTM D Flexural Strengths (psi) & Flexural Modulus (psi) 5. ASTM D Barcol Hardness 6. ASTM D Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels. 7. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials. 1.4 SUBMITTALS A. Product Data: Submit sufficient manufacturer's data to indicate compliance with these specifications, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. Fiberglass Reinforced Wall Panels
2 B. Shop Drawings: Submit elevations of each wall showing location of paneling and trim members with respect to all discontinuities in the wall elevation. C. Selection Samples: Submit manufacturer s standard color pattern selection samples representing manufacturer's full range of available colors and patterns. D. Samples for Verification: Submit appropriate section of panel for each finish selected indicating the color, texture, and pattern required. 1. Submit complete with specified applied finish. 2. For selected patterns show complete pattern repeat. 3. Exposed Molding and Trim: Provide samples of each type, finish, and color. E. Manufacturers Material Safety Data Sheets (MSDS) for adhesives, sealants and other pertinent materials prior to their delivery to the site (available as downloads for most Nudo s products at or by contacting Nudo at info@nudo.com). 1.5 QUALITY ASSURANCE A. Conform to building code requirements for interior finish for smoke and flame spread requirements as tested in accordance with: 1. ASTM E 84 (Method of test for surface burning characteristics of building Materials) a. Wall Required Rating Class [C]. B. Sanitary Standards: System components and finishes to comply with: 1. United States Department of Agriculture (USDA) requirements for food preparation facilities, incidental contact. 2. Food and Drug Administration (FDA) 1999 Food Code Canadian Food Inspection Agency (CFIA) requirements. 1.6 DELIVERY, STORAGE AND HANDLING A. Deliver materials factory packaged on strong pallets. B. Store panels and trim lying flat, under cover and protected from the elements. Allow panels to acclimate to room temperature (70 ) for 48 hours prior to installation. 1.7 PROJECT CONDITIONS A. Environmental Limitations: Building are to be fully enclosed prior to installation with sufficient heat (range of 60 to 75 ) and ventilation consistent with good working conditions for finish work B. During installation and for not less than 48 hours before, maintain an ambient temperature and relative humidity within limits required by type of adhesive used and recommendation of adhesive manufacturer. 1. Provide ventilation to disperse fumes during application of adhesive as recommended by the adhesive manufacturer. Fiberglass Reinforced Wall Panels
3 1.8 WARRANTY A. Furnish one year guarantee against defects in material and workmanship. PART 2 - PRODUCTS 2.1 ACCEPTABLE MANUFACTURER A. Nudo; 1500 Taylor Avenue, Springfield, IL (217) FAX (217) info@nudo.com B. Product: FiberScore FRP with Sani-Coat 2.2 PANELS A. Fiberglass reinforced thermosetting polyester resin panel sheets complying with ASTM D Coating: Multi-layer print, primer and finish coats or applied over-layer. 2. Dimensions: a. Thickness (2.29mm) nominal b. Width - 4'-0 (1.22m) nominal c. Length [10-0 (3.0m)][8-0 (2.4m) ][As indicated on the drawings] nominal 3. Tolerance: a. Length and Width: +/-1/8 (3.175mm) b. Square - Not to exceed 1/8 for 8 foot (2.4m) panels or 5/32 (3.96mm) for 10 foot (2.4m) panels B. Properties: Resistant to rot, corrosion, staining, denting, peeling, and splintering. 1. Flexural Strength x 10 4 psi per ASTM D 790. (7.0 kilogram-force/square 2. Flexural Modulus x 10 5 psi per ASTM D 790. (217.9 kilogram-force/square 3. Tensile Strength x 10 3 psi per ASTM D 638. (4.9 kilogram-force/square 4. Tensile Modulus x 10 5 psi per ASTM D 638. (112.5 kilogram-force/square 5. Water Absorption % per ASTM D Barcol Hardness (scratch resistance) of as per ASTM D Izod Impact Strength of 72 ft. lbs./in ASTM D 256 C. Back Surface: Smooth. Imperfections which do not affect functional properties are not cause for rejection. D. Front Finish: [As Indicated on the Drawings] [In accordance with preapproved sample. Information available from the Architect s Office][ } a. Color: [Specifier to choose.] 1) FiberScore FRP with Sani-Coat FRP is available in the following colors: a) 50-G44 White Fiberglass Reinforced Wall Panels
4 b) 698-G44 Almond b. Fire Rating FiberScore FRP is available in Class C (III) Fire Rating. c. Size: [Specifier to choose, or as indicated on drawings.] standard sizes are; 1) FiberScore FRP a) 48 x 96 [1.2m x 2.4m] x.090 (3mm) nom. b) 48 x 120 [1.2m x 3m] x.090 (3mm) nom. 2.3 ACCESSORIES A. Fasteners: Provide appropriate fasteners and accessories as required to properly complete installation B. Adhesive: Provide panel adhesive as recommended by panel manufacturer. C. Trim and Seam Treatment: 1. Manufacturer: Acceptable to panel manufacturer. 2. Manufacturer Designation: [Corner molding] [Division bar] [Cap] [Specify manufacturer designation.]. Specifier Note: Retain one of three subparagraphs below to suit project requirements. 3. Material and Color: Color matched acrylic latex caulk. 4. Material and Color: [Aluminum moldings ] [Specify color ] 5. Material and Color: [Standard PVC Moldings ] [Specify color ] EXECUTION 2.4 PREPARATION A. Examine backup surfaces to determine that corners are plumb and straight, surfaces are smooth, uniform, clean and free from foreign matter, nails countersunk, joints and cracks filled flush and smooth with the adjoining surface. 1. Verify that stud spacing does not exceed 24 (61cm) on-center. B. Repair defects prior to installation. 1. Level wall surfaces to panel manufacturer s requirements. Remove protrusions and fill indentations. 2.5 INSTALLATION A. Comply with manufacturer's recommended procedures and installation sequence. B. Cut sheets to meet supports allowing 1/8 (3 mm) clearance for every 8 foot (2.4m) of panel. Fiberglass Reinforced Wall Panels
5 1. Cut and drill with carbide tipped saw blades or drill bits, or cut with shears. 2. Pre-drill fastener holes 1/8 (3mm) oversize with high speed drill bit. a. Space at 8 (200mm) maximum on center at perimeter, approximately 1 from panel edge. b. Space at in field in rows 16 (40.64cm) on center, with fasteners spaced at 12 (30.48 cm) maximum on center. C. Apply panels to board substrate, above base, vertically oriented with seams plumb and pattern aligned with adjoining panels. 1. Install panels with manufacturer's recommended gap for panel field and corner joints. a. Adhesive trowel and application method to conform to adhesive manufacturer s recommendations. b. Drive fasteners for snug fit. Do not over-tighten. D. Apply panel moldings to all panel edges using silicone sealant providing for required clearances. 1. All moldings must provide for a minimum 1/8 (3mm) of panel expansion at joints and edges, to insure proper installation. 2. Apply sealant to all moldings, channels and joints between the system and different materials to assure watertight installation. 2.6 CLEANING A. Remove excess sealant from panels and moldings. Wipe panel down using a damp cloth and mild soap solution or cleaner. B. Refer to manufacturer's specific cleaning recommendations Do not use abrasive cleaners. END OF SECTION Fiberglass Reinforced Wall Panels
Marlite Guide Specification 01/15/2016 Decorative FRP Wall Panels SECTION DECORATIVE FIBERGLASS REINFORCED WALL PANELS
Note: This document contains information and notes in hidden text. If you need assistance to view & hide text, instructions are at this link: http://www.marlite.com/hidden-notes-instructions.aspx Delete
More informationFaçade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware
More informationFiberLite FRP. Technical Data. Class C - Pages 1-2 Class A - Pages 3-4
FiberLite FRP Technical Data Class C - Pages 1-2 Class A - Pages 3-4 Technical Data NUDO FiberLite FRP 3004N.C Rev. 11 8/13 NUDO FiberLite FRP Class C Embossed and Smooth Wall & Ceiling Panels NUDO FiberLite
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationPRODUCT SPECIFICATIONS
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: High density cast resin architectural products, including columns, panels, caps, bases, trim elements and balustrade systems. Specifier Note: Article below
More information(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand
(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand The purpose of this guide specification is to assist the specifier in correctly specifying solid surface wall cladding, shower
More informationRev. 07 8/15 Please Read Disclaimers:
FiberCorr panels Guidelines 6005.FC Rev. 07 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems
More informationSECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS
SECTION 07 44 50 FIBERGLASS REINFORCED POLYMER (FRP) PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Design, Engineering, manufacturing and erection of fiberglass reinforced panels. Delegated Design of
More informationENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610
ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610 PART 1 - GENERAL 1.1 SCOPE OF WORK FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED STAIR TREADS A. The CONTRACTOR shall furnish,
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More information1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards
SECTION 07185 TRAFFIC MEMBRANE PART 1 GENERAL 1.1 SECTION INCLUDES A. Traffic membrane, consisting of welded seam PVC waterproofing, over f following surfaces: 1. Decks, balconies, and sun porches 2. Walkways,
More informationSECTION Summit Phenolic Lockers (Solid Phenolic Lockers)
SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with
More informationMay 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building
May 8, 2017 ADDENDUM #1 IFB 17-082 Resin Floor System For Highway Department Central District Building Addendum #1 is being issued to offer an alternate resin flooring system. 096700 FLUID-APPLIED FLOORING
More information6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware
Tools/materials you might need for proper installation 6D galvanized screws 100% silicone caulking caulking gun acrylic latex caulk shims tape measure 1/8 drill bit Phillips screw driver cardboard china
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationSECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1
ENGINEERING SPECIFICATION PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC 1 PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS
More information09/07/07 GLASSFIBER REINFORCED GYPSUM (GRG) C. S. I Spec Master Spec Page 1
Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced gypsum (GRG) shapes in accordance with the requirements of the contract documents..02 The installing contractor shall be responsible
More informationSection HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.
P a g e 1 PART I. GENERAL 1.01 Scope A. Furnish and install SoftWalls HIGH-TENSION Acoustical & Tackable Stretch Fabric Systems B. Related Work Specified Elsewhere: 1.Preparation of a smooth, flat and
More informationENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING 1 PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING A. The CONTRACTOR shall furnish,
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS January 24, 2014 06600-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS
More informationCold Storage. Controlled Environments. CLEANsafe Solutions designed for the most demanding Controlled Environments
Cold Storage Controlled Environments Solutions designed for the most demanding Controlled Environments Cold Storage Finishes Kingspan Controlled environments take many different forms and the performance
More informationGuideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS
Guideline Specifications GDON MARQUIS LINEAR CEILING PANEL SYSTEMS Note to Specifier: MARQUIS Systems are a finished decorative/functional product and should be specified per The Construction Specifications
More informationB. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.
SECTION 102600 - WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)
SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationArchitectural Specifications, Section Phenolic Lockers
Architectural Specifications, Section 10500 Phenolic Lockers Hollman, Inc., 1825 W. Walnut Hill Lane, Irving, TX 75038, (972) 815-4000, www.hollman.com 1.0 GENERAL 1.1 SECTION INCLUDES A. Phenolic Lockers.
More informationFirst Class Building Products, Inc.
PART 1- GENERAL 1.01 SUMMARY First Class Building Products, Inc. A. Related sections: 1.02 REFERENCES GLASS-FIBER REINFORCED GYPSUM (GRG) 1. Division 5, Metal Stud Framing 2. Division 7, Sealants 3. Division
More informationSPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
More informationSeries 3000 Pocket Doors
Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification
More informationDRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board
1. Scope 1.1 This standard defines the minimum prescriptive quality and performance requirements for Fiberreinforced Magnesium Cement Board products intended for use in buildings in North America. For
More informationCSI GUIDE Countertops
CSI GUIDE Countertops Part 1 General 1.0 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including general and supplementary conditions and Division 1 Specification Sections, apply
More informationGuideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
More informationSECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationThermalShell Modular Insulated Pre-Cast Panels
412 N. California St. Building #2 Sycamore IL, 60178 Phone: 815.899.0224 Fax: 815.899.0226 E-mail: info@thermalshell.com Web: www.thermalshell.com ThermalShell Modular Insulated Pre-Cast Panels Construction
More informationSL150 Guide Specification
SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union
More informationSECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof
SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812
More informationSECTION ACOUSTICAL PANEL CEILINGS
SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationSection GYPSUM DRYWALL
Section 09250 GYPSUM DRYWALL 1.00 GENERAL: A. Gypsum Association Specification GA216 and manufacturer's instruction (whichever is more stringent). 2.00 DRYWALL MATERIALS: A. Exposed Gypsum Board: ASTM
More information1.02 DESCRIPTION A. This Section specifies furnishing and installing Surface Applied Detectable/Tactile Warning Surface Tiles where indicated.
SURFACE APPLIED DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
More informationWall, Ceiling & Laminated Liner Panels
Wall, Ceiling & Laminated Liner Panels Quality, commitment and innovation Glasteel, with more than 45 years of experience, is the second largest manufacturer of Fiberglass Reinforced Panels in the North
More informationAlply CLASSIC WALL Architectural Insulated Panel Wall System
SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated
More informationACOUSTICAL WALL TREATMENT SECTION 09840
ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationEXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,
More information1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.
WOOD FLOORING GENERAL INFORMATION 1.1 This section applies to factory finished wood strip flooring. 1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards. 1.3
More informationCAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES
CAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES PART 1 GENERAL 1.01 DESCRIPTION A. This Section includes Specifications for furnishing and installing permanently embedded Cast In Place Tactile
More informationENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES March 16, 2015 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS STRUCTURAL SHAPES PART
More informationSECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board
SECTION 09260 GYPSUM WALLBOARD SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Gypsum board at new wall partitions or where indicated on drawings. 1.2 REFERENCED STANDARDS A. ASTM C36 - Gypsum Wallboard
More informationCOLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100
COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,
More information5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric
Section 097714 Medium-Tension Fabric Wall System [SnapLoc ] Part 1 General 1.1 Related Documents A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS
Page 1 of 17 SECTION 11 4600 FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and
More informationPLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11
Plasterform Inc. 1180 Lakeshore Road East, Mississauga, Ontario Canada L5E 1E9 t 905.891.9500 1.800.268.4534 f 905.891.2232 plasterform.com SECTION 09285 PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG)
More informationWallflowers RUBBER WALL BASE
Product Description Flexco Rubber Wall Base is a true, 100% thermoset (TS) rubber wall base. wall base is incredibly durable, allowing it to stand up to a wide range of use when compared to vinyl wall
More informationSECTION SOLID SURFACING COUNTERTOPS
SECTION 12 3661 SOLID SURFACING COUNTERTOPS This Section specifies Wilsonart Solid Surface countertops produced by Wilsonart LLC. Wilsonart Solid Surface is an acrylic resin based solid surfacing material
More informationMANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More information1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.
Permatherm Specification SECTION 07435 (CSI MasterFormat 1995) SECTION 07 42 43 (CSI MasterFormat 2004) SECTION 07 42 13.19 (CSI MasterFormat 2012) INSULATED METAL and FRP WALL PANELS Part 1: General General:
More informationStudent Services & Classroom Addition
SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationPERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960
STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary
More informationSECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.
SECTION 08870 WINDOW FILM PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and security films. 1.2 RELATED SECTIONS A. Section 08500 - Windows; windows to receive architectural window film. B. Section 08600
More informationMDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls
MicroTex Eggshell Micro-Textured Ceramic Coating for Walls Specification Guide 95: 9770 Special Wall Finishes 88: 9800 Special Coatings Part 1 General 1.01 SUMMARY A. This section specifies the furnishing
More information2000 POCKET DOOR TECHNICAL DATA
2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose
More informationFRP Floor Panels Standard Specification
1. Scope Furnish all labor, materials, equipment and incidentals necessary to install the fiberglass reinforced polymer (FRP) products as specified herein. The work covered by this section shall include
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation
More informationOPACI-COAT Water-base Silicone Glass Coating
www.icdcoatings.com 1.360.546.2286 DIVISION 08 00 00 SECTION 08 00 00 GLASS WALL CLADDING Please note that this specification is not complete until reviewed by a specification professional. Certain parts
More informationSECTION STILE AND RAIL WOOD DOORS
SECTION 08 1433 NOTE: THIS SECTION USES THE TERM "ARCHITECT." CHANGE THIS TERM TO IDENTIFY THE DESIGN PROFESSIONAL AS DEFINED IN THE AGREEMENT OR GENERAL CONDITIONS OF THE CONTRACT. PART 1 GENERAL 1.01
More informationFRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED
FRP Specifications Section 06 71 00 Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED 11.2016 BRISTOL FACILITY 400 Commonwealth Ave., P. O. Box 580, Bristol, VA 24203-0580
More informationTRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS
TRIDENT SEC 04 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS A.
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationSECTION EXPANSION CONTROL
SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationLINEAR METAL CEILINGS Section
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationB. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.
SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationAluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL
Aluminum Flush Doors and Frames SPECIFICATIONS Section 081116 [8120] Cline Aluminum Doors, Inc. 112 32nd Avenue West Bradenton, FL 34205-8907 Toll-Free (800) 648-6736 Office (941) 746-4104 Fax (941) 746-5153
More informationSECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.
SECTION 10155 TOILET COMPARTMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Plastic laminate partitions. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Concealed steel support members. B. Section
More information1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.
SECTION 071413 HOT FLUID APPLIED RUBBERIZED ASPHALT WATERPROOFING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels.
More information(Project Location) (your firm's name)
SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections
More informationSECTION RESILIENT SHEET FLOORING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 65 16 A. This Section includes resilient sheet flooring. 1. Use this section only for NCA projects. 2. Delete between // ---- // if not applicable to project.
More informationGuide Specifications for Prodema PRODEX External Cladding
Guide Specifications for Prodema PRODEX External Cladding SECTION 07420 Exterior Wall Cladding Note: These specifications were current at the time of publication but are subject to change at any time without
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationSECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove
Duo-Gard Industries Inc. 40442 Koppernick Road Canton, Michigan 48187 Phone (734) 207-9700 Fax (734) 207-7995 www.duo-gard.com SECTION 08 45 13 Structured Polycarbonate Panel Assemblies Series 3500 BPC
More informationConstruction Specification
PART 1 - GENERAL 1.01 SUMMARY A. Furnish all labor, materials, tools and equipment required for completing tile work and related items indicated on the drawings and herein specified. B. Related work specified
More informationSection Glass Wall Cladding
OPACI-COAT-300 GLASS WALL CLADDING SUGGESTED SPECIFICATION PART 1 - GENERAL 1.01 DESCRIPTION A. General Information 1. The other contract documents complement the requirements of this section. 2. Requirements
More informationSOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES
PART 1 - GENERAL SECTION 122413 - ROLLER WINDOW SHADES 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationby Rollfab Metal Products
by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and
More informationSECTION 07530CP EPDM MEMBRANE ROOFING
PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL
More informationNORTH TONAWANDA CSD Capital Projects 2015
SECTION 081743 - FRP DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationSection Wood Grille Ceiling Panels
Section 095426 Wood Grille Ceiling Panels PART 1 GENERAL RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification sections
More informationNarrow Modular Pavers (NMP) for Sand-Set Installations
The following specification refers to the Stepstone, Inc. product known as: Narrow Modular Pavers (NMP) for Sand-Set Installations Narrow Modular Pavers are part of the California Architectural Paver line
More informationSECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationvinyl Drywall trims montreal toronto CalGary EDmOntOn vancouver BA Metal Bead Brochure Aug 12.indd :31 AM
vinyl Drywall trims MONTREAL TORONTO CALGARY EDMONTON VANCOUVER accessory specifications 1 PRODUCT NAME 2 MANUFACTURED FOR BAILEY by : Additional products available for Drywall, Stucco and for EIFS assemblies.
More informationFRP Baffle Wall Standard Specification-Section 11350
-Section 11350 1. General Information The work covered by this section shall include (but shall not be limited to) materials and installation for the fiberglass reinforced plastic (FRP) Baffle Wall System.
More informationThermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)
PAGE 1 OF 7 1. GENERAL 1.1 SECTION INCLUDES.1 All requirements of the contract documents form an integral part of the work specified herein; in particular refer to the general conditions and Division 1
More informationGigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationTRIDENT S8 DN 35 SECTION SAFETY AND SECURITY FILMS
TRIDENT S8 DN 35 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS
More information1. Division 09 Section "Rough Carpentry."
GREENSPOINT AND LAUDER RD. EC/PRE-KlK PAGE 1 SECTION 096400 - WOOD FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary