Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Size: px
Start display at page:

Download "Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:"

Transcription

1 Internal walls 174 Technical Advice Centre Tel:

2 Legislation and guidance - National Building Regulations Approved Document E Approved Document E (ADE) gives guidance on how to provide reasonable standards of sound insulation in dwellings and other residential buildings within. The aim of the standard is to improve the acoustic environment by reducing noise transmission both between, and within, all residential dwellings. Therefore, in addition to specifying levels of sound insulation for separating constructions, national Building Regulations Approved Document E also includes a required level of sound insulation for internal constructions. Requirement E2 states: Dwelling-houses, flats and rooms for residential purposes shall be designed and constructed in such a way that (a) Internal walls between a bedroom or a room containing a water closet, and other rooms; and (b) Internal floors provide reasonable resistance to sound. The majority of internal walls and floors must achieve R w 40 db. Element of construction Internal wall between a bathroom, or WC, and a habitable room Internal wall between a bedroom and another room within the dwelling Minimum airborne sound insulation (laboratory test result) R w 40 db 40 db However, internal walls which include a door are exempt from this requirement. Complying with the regulations Pre-Completion Testing is not required for internal wall constructions in England or Wales. Building Control check internal constructions at plan stage to ensure the details specified will meet this required performance. In, housebuilders can follow one of two routes to demonstrate compliance for new-build houses and apartments: Using Guidance s, or Using manufacturers proprietary systems Guidance s Guidance s are shown in this section incorporating British Gypsum products, where appropriate. These details are British Gypsum versions of Guidance s, which, provided they are built correctly, are deemed to achieve the regulatory requirements. Manufacturers Proprietary Systems British Gypsum Approved Systems have been laboratory tested and have shown they have the potential to achieve the required performance criteria for internal wall construction within new-build houses and flats, provided they are built correctly. bgtechnical-enquiries@bpb.com 175

3 176 Technical Advice Centre Tel:

4 Legislation and guidance (cont d) Scotland Domestic Technical Handbook Section 5: Noise On the 1st October 2010 a new version of the Domestic Technical Handbook Section 5: Noise, came into force in Scotland. This version was introduced following the first major review, for over 20 years, of the design performance requirements of previous technical handbooks. Section 5 not only aims to limit sound transmission emanating from attached buildings; from October 2010, it also covers sound from within the same dwelling if occupants are in rooms where they would expect to have some degree of peace and quiet. Standard 5.2 states: Every building, must be designed and constructed in such a way to limit the transmission of source noise from normal domestic type activities, through a wall or floor, between a room and internal space where noise is likely to occur, to a level that will not cause inconvenience to the building occupants. Standard 5.2 applies to an internal wall or floor forming a room in a dwelling, or a room in a residential building, which is capable of being used for sleeping. The majority of internal walls and floors must achieve R w 43 db. Element of construction An internal wall or floor forming a room in a dwelling which is capable of being used for sleeping Minimum airborne sound insulation (laboratory test result) R w 43 db It does not apply to a wall between an en-suite bathroom and the room it serves. Complying with the regulations Post-Completion Testing is not required for internal wall constructions in Scotland. Building Control check internal constructions at plan stage to ensure the details specified will meet the required performance. Generic Internal s Generic Internal s are shown in this section incorporating British Gypsum products, where appropriate. These details are British Gypsum versions of Generic Internal s, which, provided they are built correctly, are deemed to achieve the regulatory requirements. In Scotland, housebuilders can follow one of two routes to demonstrate compliance for new-build houses and apartments; Using Generic Internal s, or Using manufacturers proprietary systems Manufacturers Proprietary Systems British Gypsum Approved Systems have been laboratory tested and have shown they have the potential to achieve the required performance criteria for internal wall construction within new-build houses and flats, provided they are built correctly. bgtechnical-enquiries@bpb.com 177

5 System reference for internal walls Solutions Build method Detail / Wall type Category Standard acoustic performance (England and Wales) Internal wall solutions to meet minimum national Building Regulations requirements in. Steel Proprietary British Gypsum Approved System Proprietary Proprietary Proprietary Wall type A Wall type B Guidance Masonry Wall type C Guidance Wall type D Wall type D Timber Proprietary British Gypsum Approved System Proprietary Proprietary Wall type A Wall type B Guidance 178 Technical Advice Centre Tel:

6 Description Page Detail GypWall CLASSIC incorporating Gypframe 48 S 50 C studs and insulation 182 GypWall CLASSIC incorporating Gypframe C studs 182 GypWall RAPID db Plus incorporating 43 AS 50 AcouStuds GypWall RAPID db Plus incorporating 43 AS 50 AcouStuds and Gypframe GWR2 Nogging Channels GypWall CLASSIC incorporating Gypframe 48 S 50 C studs and insulation 185 GypWall CLASSIC incorporating 48 S 50 C studs or Gypframe C studs Aggregate block wall minimum 120kg/m 2 (excluding finish) lined with the DriLyner BASIC system or 13mm Thistle plaster Aircrete block wall minimum 75kg/m 2 (including finish) lined with the DriLyner BASIC system or minimum 90kg/m 2 (including finish) lined with 13mm Thistle plaster mm timber studs mm timber studs with insulation mm timber studs with insulation mm timber studs with insulation mm timber studs bgtechnical-enquiries@bpb.com 179

7 System reference for internal walls (cont d) Solutions Build method Detail / Wall type Category Standard acoustic performance (Scotland) / Standard plus acoustic performance (England and Wales) Internal wall solutions to meet minimum national Building Regulations requirements in Scotland, or to provide enhanced performance for homes in. Steel Proprietary British Gypsum Approved System Proprietary Scotland Wall type 2 Wall type 2A Generic Internal Scotland Masonry Wall type 3 Generic Internal Scotland Wall type 3A Wall type 3B Wall type 4 Timber Proprietary British Gypsum Approved System Proprietary Scotland Wall type 1 Wall type 1A Generic Internal Scotland 180 Technical Advice Centre Tel:

8 Description Page Detail GypWall RAPID db Plus incorporating 43 AS 50 AcouStuds and insulation GypWall RAPID db Plus incorporating 43 AS 50 AcouStuds, Gypframe GWR2 Nogging Channels and insulation GypWall CLASSIC incorporating 48 S 50 C studs or Gypframe C studs 197 GypWall CLASSIC incorporating 48 S 50 C studs or Gypframe C studs and insulation Concrete block wall minimum 120kg/m 2 (excluding finish) lined with the DriLyner BASIC system or 13mm Thistle Plaster Aggregate block wall, density kg/m 3, lined with the DriLyner BASIC system or 13mm Thistle plaster Aggregate block wall, density kg/m 3, lined with the DriLyner BASIC system or 13mm Thistle plaster Aircrete block, density kg/m 3, wall lined with the DriLyner BASIC system or 13mm Thistle plaster mm timber studs with insulation mm timber studs with insulation mm timber studs mm timber studs with insulation bgtechnical-enquiries@bpb.com 181

9 details Standard performance () Steel frame walls 152 GypWall CLASSIC (Gypframe 48 S 50 C Studs at 600mm centres, with insulation) PSR A R w 40 db Maximum height 2500mm Overall construction nominal width 75mm Gypframe 48 S 50 C Studs at 600mm centres 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity Lined with a single layer of 12.5mm Gyproc WallBoard each side British Gypsum Approved System NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 153 GypWall CLASSIC (Gypframe 70 S 50 C Studs at 600mm centres, without insulation) PSR A R w 40 db Maximum height 3600mm Overall construction nominal width 97mm Gypframe 70 S 50 C Studs at 600mm centres Lined with a single layer of 12.5mm Gyproc SoundBloc each side British Gypsum Approved System 182 NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Technical Advice Centre Tel:

10 details Standard performance () (cont d) Steel frame walls 154 GypWall RAPID db Plus (Gypframe 43 AS 50 AcouStuds at 450mm centres, without insulation) PSR A139A005 R w 40 db Maximum height 2700mm Overall construction nominal width 75mm 43mm Gypframe 43 AS 50 AcouStuds at 450mm centres Use Gypframe Floor & Ceiling Channel vertically at abutments in GypWall RAPID db Plus rather than Gypframe stud section Lined with a single layer of 15mm Gyproc SoundBloc RAPID each side 32mm British Gypsum Drywall Screws are used to fix 15mm Gyproc SoundBloc RAPID in the GypWall RAPID db Plus system The innovative door detailing of GypWall RAPID db Plus means that overboarding is not required during installation and, as a result, plasterboard waste is considerably reduced British Gypsum Approved System NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical-enquiries@bpb.com 183

11 details Standard performance () (cont d) Steel frame walls 155 GypWall RAPID db Plus (Gypframe 43 AS 50 AcouStuds at 900mm centres, without insulation) PSR A139A001 R w 40 db Maximum height 2400mm Overall construction nominal width 75mm 43mm Gypframe 43 AS 50 AcouStud at 900mm centres Use Gypframe Floor & Ceiling Channel vertically at abutments in GypWall RAPID db Plus rather than Gypframe stud section Gypframe GWR2 Nogging Channel at mid-height Lined with a single layer of 15mm Gyproc SoundBloc RAPID each side 32mm British Gypsum Drywall Screws are used to fix 15mm Gyproc SoundBloc in the GypWall RAPID db Plus system The innovative door detailing of GypWall RAPID db Plus means that overboarding is not required during installation and, as a result, plasterboard waste is considerably reduced British Gypsum Approved System NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 184 Technical Advice Centre Tel:

12 details Standard performance () (cont d) Steel frame walls 156 Guidance 60 mins BS Maximum height 3400mm or 4600mm GypWall CLASSIC (internal wall type A) Overall construction nominal width 100mm Stud options: Gypframe 48 S 50 C Studs at 600mm centres or Gypframe 70 S 50 C Studs at 600mm centres Board options: Double layer of 12.5mm Gyproc WallBoard TEN each side or Double layer of 12.5mm Gyproc SoundBloc each side PSR A Guidance NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 157 Guidance GypWall CLASSIC (internal wall type B) Overall construction nominal width 75mm Maximum height 2500mm (at 600mm centres) PSR A Maximum height 2500mm or 2700mm 2700mm (at 400mm centres) Gypframe 48 S 50 C Studs at 400mm or 600mm centres 25mm Isover Acoustic Partition (APR 1200) in the stud cavity Board options: Single layer of 12.5mm Gyproc WallBoard TEN each side or Single layer of 12.5mm Gyproc SoundBloc each side Guidance NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical-enquiries@bpb.com 185

13 Gypframe metal products The modern, engineered alternative to traditional timber and blockwork construction, Gypframe-based wall, ceiling and floor systems are quicker and easier to install, whilst meeting the highest performance requirements. Up to 50% lighter than equivalent timber systems, and up to 70% lighter than blockwork, Gypframe metal products are easier to transport and offer a high strength to weight ratio for guaranteed performance and long life. Gypframe components are easy to cut on site, non-flammable and won t rot, twist or warp. They can be stored outside and installed in any weather, making it easier to schedule work. Gypframe profiles are manufactured using the patented UltraSTEEL process and conform to EN The UltraSTEEL process gives the components greater strength, makes fixing easier and improves screw retention and pull-out by up to 20%. That s why only systems built using Gypframe metal components qualify for the British Gypsum SpecSure lifetime system warranty peace of mind that they will perform to specification throughout their entire installed life. Isn t it amazing the difference a few folds can make? British Gypsum is committed to continuous product development. That s why in 1998 we introduced the first folded edge channel exclusively for the housing market. Now, working in conjunction with our customers, we ve brought that innovation to the entire market to ensure easier manual handling of our products and to contribute to on-site health and safety. British Gypsum has now introduced folded edges to the entire Gypframe channel range to provide our customers with a full range of products that have a safer working edge. 186 Technical Advice Centre Tel:

14 Metal innovations by British Gypsum 1974 Introduced lightweight metal framing systems into the UK 1978 Launched MF7 ceiling system 1992 Developed the first dedicated housing system GypWall RAPID 1998 Introduced the first folded edge product for house building 2002 Introduced the AcouStud, with a patented stud profile, for increased acoustic performance 2010 Introduced the new 50mm Gypframe folded edge channel 2012 Folded edges introduced to the entire range of Gypframe channels 2013 Gypframe metal awarded BES 6001 Very Good Gypframe metal framing components have been certified Very Good under BES 6001 the first metal drylining components to achieve this. They join British Gypsum s wide range of certified products, including Gyproc plasterboards, Glasroc specialist boards and Thistle plasters. This means we re now able to offer you a system solution where the majority of the constituent components (metal framing, plasterboard and plaster), achieve the Very Good standard, earning points towards the Code for Sustainable Homes within the materials category (under issue MAT 2). bgtechnical-enquiries@bpb.com 187

15 Product focus Glasroc H TILEBACKER Behind every perfect tile job A high performance board specifically designed for use in wet areas such as bathrooms and kitchens. Ready primed for direct tiling, Glasroc H TILEBACKER is up to a third lighter than cement boards and faster to install, leaving more time for tiling. Quick and easy to install: No power tools, pre-drilling or specialist fixings required, just score and snap to size. Simply screw in place with British Gypsum Drywall or Drywall Timber Screws Easy to construct saving time and effort, no pre-treatment required 12.5mm board can be fixed to masonry backgrounds using Gyproc Dri-Wall Adhesive and British Gypsum Nailable Plugs You can use your current and favoured materials as it s compatible with standard tile adhesives Lighter board for manual handling and on-site logistics It offers moisture and mould resistant properties, combined with superior dimensional stability, making it the high performance alternative to plywood and cement boards. The range includes both 12.5mm and 6mm thick boards offering the full solution for floors and walls. The 6mm board can be curved to fit walls to a radius of 600mm and when used for floors it is also suitable for use with electric underfloor heating systems. Compatible with all British Gypsum systems and no special framework required. For example, Glasroc H TILEBACKER 12.5mm can be used within the GypWall CLASSIC system, with studs at 600mm centres. This will then support up to 32kg/m 2 of any tile type. 188 Technical Advice Centre Tel:

16 details Standard performance () (cont d) Masonry walls 158 Guidance Aggregate concrete block 120kg/m 2 (internal wall type C) Masonry block wall minimum 120kg/m 2 Finished with 13mm Thistle plaster (see pages 82 and 83) or drylined with 12.5mm Gyproc WallBoard using DriLyner BASIC system Guidance 159 Aircrete concrete block (internal wall type D) Masonry non-loadbearing block wall, minimum 90kg/m 2 Guidance Finished with 13mm Thistle plaster both sides (see pages 82 and 83) or Masonry non-loadbearing block wall minimum 75kg/m 2 Drylined with 12.5mm Gyproc WallBoard TEN using DriLyner BASIC system bgtechnical-enquiries@bpb.com Guidance 189

17 Product focus Choosing Thistle plasters There are many factors to consider when choosing an internal wall finish for a new house or apartment. What kind of performance do I need? What level of finish is required? How will the rooms be used? If you choose two-coat systems, they ll help you meet regulations and environmental requirements, as well as mandatory airtightness standards. You can also be sure of a robust solid finish that will help improve sound performance and reduce air leakage. 190 Thistle plasters provide technical solutions, developed to meet the changing needs of housebuilders and homeowners. Whether you choose the two-coat systems or use a plaster skim on drylined walls, you can select from a range of different products. Thistle plasters provide the demanding lining finish properties you need from extra durable plasters that protect against scuffs and knocks, to plasters specifically designed for different types of background. Thistle plasters; creating wall solutions for modern homes. Technical Advice Centre Tel:

18 Upgrading new homes Many homeowners prefer the reassuring feel of a solid wall finished with two-coat Thistle plaster. It s easier to fix to, smooth to the touch and provides additional sound proofing to help stop noise problems within the home. With Thistle plastered walls you can make every home feel special: Give homeowners robust, solid walls throughout their home, or in selected rooms Make fixing heavy objects easier, shelves in a study, for instance, or a 50" flat screen TV in the lounge Resist minor knocks and enable any damage to be repaired quickly and easily When it s time to redecorate, wallpaper is easier to strip from plastered walls bgtechnical-enquiries@bpb.com 191

19 details Standard performance () (cont d) Timber frame walls 160 R w 40 db Timber stud (600mm centres, without insulation) Overall construction nominal width 93mm Minimum 63mm x 38mm non-loadbearing timber studs at 600mm centres Timber noggings are normally required. Please seek advice from timber supplier Lined with a single layer of 15mm Gyproc SoundBloc each side PSR A British Gypsum Approved System 161 R w 40 db Timber stud (600mm centres, with insulation) Overall construction nominal width 88mm Minimum 63mm x 38mm non-loadbearing timber studs at 600mm centres Timber noggings are normally required. Please seek advice from timber supplier 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity Lined with a single layer of 12.5mm Gyproc SoundBloc each side PSR A Technical Advice Centre Tel: British Gypsum Approved System

20 details Standard performance () (cont d) Timber frame walls 162 R w 41 db Timber stud (600mm centres, with insulation) Overall construction nominal width 88mm Minimum 63mm x 38mm non-loadbearing timber studs at 600mm centres Timber noggings are normally required. Please seek advice from timber supplier 65mm Isover Acoustic Partition Roll (APR 1200) in the cavity Lined with a single layer of 12.5mm Gyproc WallBoard each side PSR A British Gypsum Approved System bgtechnical-enquiries@bpb.com 193

21 details Standard performance (cont d) Timber frame walls 163 Guidance 60 mins BS Timber stud (internal wall type A) Overall construction nominal width 125mm Minimum 75mm x 38mm timber stud at 600mm centres (loadbearing ratio 60%) Timber noggings are normally required. Please seek advice from timber supplier Board options: Double layer of 12.5mm Gyproc WallBoard TEN each side or Double layer of 12.5mm Gyproc SoundBloc each side PSR A Guidance 164 Guidance Timber stud (internal wall type B) Overall construction nominal width 100mm Minimum 75mm x 38mm timber stud at 600mm centres (loadbearing ratio 60%) Timber noggings are normally required. Please seek advice from timber supplier 25mm Isover Acoustic Partition Roll (APR 1200) in the stud cavity Board options: Single layer of 12.5mm Gyproc WallBoard TEN each side or Single layer of 12.5mm Gyproc SoundBloc each side PSR A Technical Advice Centre Tel: Guidance

22 details Standard performance (Scotland) / Standard plus performance () Steel frame walls 165 GypWall RAPID db Plus (Gypframe 43 AS 50 AcouStuds at 450mm centres, with insulation) PSR A139A006 R w 43 db Maximum height 2700mm Overall construction nominal width 75mm 43mm Gypframe 43 AS 50 AcouStud at 450mm centres Use Gypframe Floor & Ceiling Channel vertically at abutments in GypWall RAPID db Plus rather than Gypframe stud section 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity Lined with a single layer of 15mm Gyproc SoundBloc RAPID each side 32mm British Gypsum Drywall Screws are used to fix 15mm Gyproc SoundBloc in the GypWall RAPID db Plus system The innovative door detailing of GypWall RAPID db Plus means that overboarding is not required during installation and, as a result, plasterboard waste is considerably reduced British Gypsum Approved System England, Wales and Scotland NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. bgtechnical-enquiries@bpb.com 195

23 details Standard performance (Scotland) / Standard plus performance () (cont d) Steel frame walls 166 GypWall RAPID db Plus (Gypframe 43 AS 50 AcouStuds at 900mm centres, with insulation) PSR A139A003 R w 44 db Maximum height 2400mm Overall construction nominal width 75mm Gypframe 43mm 43 AS 50 AcouStuds at 900mm centres Gypframe GWR2 Nogging Channels at mid-height Use Gypframe Floor & Ceiling Channel vertically at abutments in GypWall RAPID db Plus rather than Gypframe stud section 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity Lined with a single layer of 15mm Gyproc SoundBloc RAPID each side 32mm British Gypsum Drywall Screws are used to fix 15mm Gyproc SoundBloc in the GypWall RAPID db Plus system The innovative door detailing of GypWall RAPID db Plus means that overboarding is not required during installation and, as a result, plasterboard waste is considerably reduced British Gypsum Approved System England, Wales and Scotland NB The fire resistance and sound insulation performance are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 196 Technical Advice Centre Tel:

24 details Standard performance (Scotland) / Standard plus performance () (cont d) Steel frame walls 167 Generic Internal 60 mins BS Maximum height 3400mm GypWall CLASSIC incorporating 48 S 50 C studs or Gypframe 70 S 50 C studs (Internal wall type 2) Overall construction width 100mm Minimum 48mm Gypframe 48 S 50 C Studs at 600mm centres Double layer of 12.5mm Gyproc SoundBloc or double layer Gyproc WallBoard TEN to both sides Generic Internal Scotland 168 GypWall CLASSIC incorporating minimum Gypframe 48 S 50 C studs and insulation (Internal wall type 2A) Generic Internal Maximum height 2500mm Overall construction width 75mm Minimum 48mm Gypframe 48 S 50 C Studs at 600mm centres 25mm Isover Acoustic Partition Roll (APR 1200) Single layer of 12.5mm Gyproc SoundBloc or Gyproc WallBoard TEN to both sides bgtechnical-enquiries@bpb.com Generic Internal Scotland 197

25 details Standard performance (Scotland) / Standard plus performance () (cont d) Masonry walls 169 Generic Internal Aggregate concrete block 120kg/m 2 (internal wall type 3) Masonry block wall minimum 120kg/m 2 Finished with 13mm Thistle plaster (see pages 82 and 83) or drylined with 12.5mm Gyproc WallBoard using DriLyner BASIC system Generic Internal Scotland 170 Generic Internal Aggregate concrete block kg/m 3 (internal wall type 3A) Aggregate block wall, density kg/m 3 Finished with 13mm Thistle plaster (see pages 82 and 83) or drylined with 12.5mm Gyproc WallBoard using DriLyner BASIC system 198 Technical Advice Centre Tel: Generic Internal Scotland

26 details Standard performance (Scotland) / Standard plus performance () (cont d) Masonry walls 171 Generic Internal Aggregate concrete block kg/m 3 (internal wall type 3B) Aggregate block wall, density kg/m 3 Finished with 13mm Thistle plaster (see pages 82 and 83) or drylined with 12.5mm Gyproc WallBoard using DriLyner BASIC system Generic Internal Scotland 172 Aircrete concrete block (internal wall type 4) Masonry non-loadbearing block wall, minimum 90kg/m 2 Generic Internal Finished with 13mm Thistle plaster both sides (see pages 82 and 83) or Masonry non-loadbearing block wall minimum 75kg/m 2 Drylined with 12.5mm Gyproc WallBoard TEN using DriLyner BASIC system bgtechnical-enquiries@bpb.com Generic Internal Scotland 199

27 details Standard performance (Scotland) / Standard plus performance () (cont d) Timber frame walls 173 R w 43 db Timber stud Overall construction width 93mm 63mm timber studs at 600mm centres 50mm Isover Acoustic Partition Roll (APR 1200) Single layer of 15mm Gyproc SoundBloc to both sides PSR A British Gypsum Approved System England, Wales and Scotland 174 R w 43 db Timber stud Overall construction width 88mm 63mm timber studs at 600mm centres 25mm Isover Acoustic Partition Roll (APR 1200) Single layer of 12.5mm Rigidur H to both sides PSR A Technical Advice Centre Tel: British Gypsum Approved System England, Wales and Scotland

28 details Standard performance (Scotland) / Standard plus performance () (cont d) Timber frame walls 175 Timber stud Generic Internal (Internal wall type 1) Overall construction width 125mm Generic Internal 60 mins BS 75mm timber studs at 600mm centres Double layer of 12.5mm Gyproc SoundBloc or double layer of Gyproc WallBoard TEN to both sides Generic Internal Scotland 176 Timber stud Generic Internal (Internal wall type 1A) Overall construction width 100mm Generic Internal 75mm timber studs at 600mm centres 25mm Isover Acoustic Partition Roll (APR 1200) Single layer of 12.5mm Gyproc SoundBloc or Gyproc WallBoard TEN to both sides bgtechnical-enquiries@bpb.com Generic Internal Scotland 201

Creating perfect living spaces. Shaping spaces for living, with internal lining solutions that enhance lifestyles. Creating perfect living spaces

Creating perfect living spaces. Shaping spaces for living, with internal lining solutions that enhance lifestyles. Creating perfect living spaces O7 Shaping spaces for living, with internal lining solutions that enhance lifestyles 171 Discover how we are working within the residential industry to facilitate differentiation, through new, innovative,

More information

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes. O4 Creating quiet, comfortable and safe living environments between adjoining homes. 51 Discover more on legislation throughout England, Wales and Scotland in this section, and how our systems can help

More information

GypWall RAPID db Plus

GypWall RAPID db Plus Metal stud housing partition system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00

More information

C08. S04. P02 P08 Tiling

C08. S04. P02 P08 Tiling ! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C08. S04. P02 P08 Including C08. S01. P02 Finishes introduction C08 Finishes Introduction

More information

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent Separating walls Countryside Properties, ock 8, Stoke-on-Trent Separating Masonry walls Walls Separating Masonry wallswalls Approved Document E 200 Clause E Approved Document 200 - Requirements Walls >>

More information

GypWall QUIET Acoustic separating wall system

GypWall QUIET Acoustic separating wall system Acoustic separating wall system Putney Wharf, South London Acoustic separating wall system is a lightweight, non-loadbearing, twin-framed acoustic separating wall. Primarily used as sound resisting walls

More information

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Quiet Living WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE. Isover s built in sound control. Simply building to the minimum sound standards outlined in the Building Regulations won t provide the comfort

More information

GypWall AUDIO The ultimate sound insulating wall system

GypWall AUDIO The ultimate sound insulating wall system The ultimate sound insulating wall system Cineworld, Ilford 8 The ultimate sound insulating wall system is a non-loadbearing, twin frame high performance wall system that provides exceptionally high levels

More information

Tiling Tiling

Tiling Tiling 416 Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes. O4 Creating quiet, comfortable and safe living environments between adjoining homes. 51 Discover more on legislation throughout England, Wales and Scotland in this section, and how our systems can help

More information

GypLyner IWL Independent wall lining system

GypLyner IWL Independent wall lining system Independent wall lining system Photograph courtesy of Philip Brier 0 Independent wall lining system independent wall lining is a lightweight, nonloadbearing drylining which is erected independently of

More information

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL Concealed grid ceiling lining system Concealed grid ceiling lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/07/00

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury

More information

Tiling Tiling Finishes C08

Tiling Tiling Finishes C08 C08 Finishes In rooms subject to high or intermittent moisture conditions, the range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings, lightweight

More information

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide GypWall TM ROBUST GypWall ROBUST is a high impact resistant partition system for use where a more durable structure is required. The system provides a lightweight, cost-effective, non-loadbearing partition

More information

Issue date: 1st May Key changes since original publication (July 2005):

Issue date: 1st May Key changes since original publication (July 2005): Issue date: st May 008 Key changes since original publication (July 00): May 008 Pages 0 & tables a & b - spec A06A08 Sound Insulation changed from 0 to 9 Rw db rating. September 00 Pages 66 & 6 tables

More information

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL Concealed grid ceiling lining system Concealed grid ceiling lining system The Sage, Gateshead 9 Concealed grid ceiling lining system ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in

More information

C04. S11. P02 P13 Non-loadbearing timber stud

C04. S11. P02 P13 Non-loadbearing timber stud ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C0. S. P0 P Non-loadbearing timber stud Including C0. S0. P0 P8 Partitions introduction

More information

GypWall QUIET Acoustic separating wall system

GypWall QUIET Acoustic separating wall system Acoustic separating wall system 90 Al Mafraq Hospital, Abu Dhabi 0 R w db 90 0 mins is a lightweight, non-loadbearing, twin framed acoustic separating wall, primarily used as a sound resisting wall in

More information

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent ! This section includes updated information, added since it was first published in December 05. Last updated 6//06 C06. S05. P0 P GypFloor silent Including C06. S0. P0 P08 Floors and ceilings introduction

More information

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent ! This section includes updated information, added since it was first published in December 05. Last updated 30/06/06 C06. S05. P0 P GypFloor silent Including C06. S0. P0 P08 Floors and ceilings introduction

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Gypframe profiles Dimensional specifications Gypframe profiles Dimensional specifications data sheet Introduction This data sheet contains the dimensional specification of the following Gypframe components

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Gypframe profiles Dimensional specifications Gypframe profiles Dimensional specifications data sheet Introduction This data sheet contains the dimensional specification of the following Gypframe components

More information

Gypwall systems. incorporating Gyproc Habito

Gypwall systems. incorporating Gyproc Habito Gypwall systems incorpo Gyproc Habito Introduction Gyproc Habito is the next generation in plasterboard. Innovative technology combined with an exceptionally strong solid gypsum core have produced a board

More information

C04. S05. P02 P14 GypWall quiet sf

C04. S05. P02 P14 GypWall quiet sf ! This section includes updated information, added since it was first published in December 0. Last updated 0//07 C0. S0. P0 P Including C0. S0. P0 P8 Partitions introduction C0 Partitions Single frame

More information

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products. GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent

More information

Curved partition and wall lining system

Curved partition and wall lining system C05 Specialist partitions Curved partition and wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a lightweight system specifically designed to

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications Dimensional specifications Dimensional specifications data sheet Introduction Characteristics This data sheet contains the dimensional specification of the following Gypframe components Gypframe Studs,

More information

Independent twin frame high performance acoustic separating wall system

Independent twin frame high performance acoustic separating wall system C04 Partitions Independent twin frame high performance acoustic separating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a lightweight, non-loadbearing

More information

The ultimate impact resistant partition

The ultimate impact resistant partition GypWall EXTREME GypWall EXTREME The ultimate impact resistant partition GypWall EXTREME is Gypsum Industries ultimate impact resistant partition system for use where even severe duty won t suffice. It

More information

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system Concealed grid MF suspended ceiling system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

GypLyner UNIVERSAL (Ceilings)

GypLyner UNIVERSAL (Ceilings) (Ceilings) Concealed grid ceiling lining system ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in all types of buildings, from residential properties

More information

Single frame acoustic separating wall system

Single frame acoustic separating wall system C0 Partitions Single frame acoustic separating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie is a non-loadbearing partition, which provides

More information

October Plasterboard baffle. Hilti CP617 Putty Pad. Socket detailing. White Book supplement

October Plasterboard baffle. Hilti CP617 Putty Pad. Socket detailing. White Book supplement October 006 Plasterboard baffle Hilti CP67 Putty Pad White Book supplement Internal partition system socket detailing Internal partition system socket detailing Fixing electrical socket boxes into British

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system GypWall STAGGERED GypWall STAGGERED Staggered stud acoustic partition system GypWall STAGGERED is a nonloadbearing metal stud partition which provides very high levels of sound insulation. In public and

More information

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings Fire separation within concealed spaces Regulatory requirements demand that cavities and concealed spaces, in the structure or fabric of a building, are sub-divided or sealed by means of cavity barriers

More information

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide is a sound insulating floor system designed for use in the residential sector. It is specified in conversion or improvement work to upgrade an existing timber joist floor to meet the acoustic requirements

More information

C07. S04. P02 P10 GypLyner universal

C07. S04. P02 P10 GypLyner universal ! This section includes updated information, added since it was first published in December 05. Last updated 4/06/07. S04. P0 P0 GypLyner universal Including. S0. P0 P04 Linings introduction Linings Introduction

More information

Single frame acoustic separating wall system

Single frame acoustic separating wall system GypWall QUIET SF GypWall QUIET SF Single frame acoustic separating wall system GypWall QUIET SF metal stud partition is a lightweight, non-loadbearing, single frame wall system. Subject to Local Authority

More information

Quantity take-off details

Quantity take-off details Quantitiy take-off details 6 Quantity take-off details Quantities Choose system specification / height or area as required, as given in the left hand column. Read across the columns to determine the quantity

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 16/12/2016 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

Technical performance and principles of system design

Technical performance and principles of system design Service installations Technical Service installations Services within partitions and lining cavities The installation of electrical services must always be carried out strictly in accordance with the National

More information

Selecting floors and ceilings

Selecting floors and ceilings floors and ceilings email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health 89 floors and ceilings Introduction 9 Solutions - key systems 9 Solutions for concrete floors 9 - Dense slab 9 This

More information

Boards. Products - Boards.

Boards. Products - Boards. Products - Boards Boards Gyproc plasterboards are the ultimate lining solution for today's buildings, providing high levels of fire, sound, thermal, moisture and impact resistance to create modern internal

More information

The extra strong, extra durable, sound resistant system that you can direct fix to

The extra strong, extra durable, sound resistant system that you can direct fix to C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising

More information

Selecting partitions

Selecting partitions email: bgtechnical.enquiries@bpb.com www.british-gypsum.com/health Introduction 6 Performance matrix 8 Worked examples 0 your partition type Solutions up to R w db This section will guide you through the

More information

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide systems provide simple and effective techniques for fixing Gyproc plasterboards or Gyproc thermal laminates to brick, block, and concrete walls. They can be used in all building types in both new-build

More information

Tiling. Tiling.

Tiling. Tiling. Tiles can be applied to drylined walls or the surface of lightweight partition systems to dado level or above. can be carried out in any type of building either in dry areas or in areas subject to intermittent

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

C06. S06. P02 P20 Loadbearing timber joist floors

C06. S06. P02 P20 Loadbearing timber joist floors ! This section includes updated information, added since it was first published in December 05. Last updated 6//06 C06. S06. P0 P0 Loadbearing timber joist floors Including C06. S0. P0 P08 Floors and ceilings

More information

GypWall AUDIO The ultimate cinema wall system

GypWall AUDIO The ultimate cinema wall system The ultimate cinema wall system 9 Vox Cinemas, Muscat City Centre - Sultanate of Oman 7 0 R w db 0 0 mins is a non-loadbearing, twin frame high performance wall system that provides exceptionally high

More information

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall ! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05

More information

PLASTERBOARD PORTFOLIO A complete range for any application

PLASTERBOARD PORTFOLIO A complete range for any application PLASTERBOARD PORTFOLIO A complete range for any application PAGE 2 PAGE 3 PERFORMANCE BOARDS Siniat plasterboard drylining systems provide economic, high performance options to meet a wide range of building

More information

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

Tiling.  Capital Gate Hotel, Abu Dhabi - UAE 166 202 Capital Gate Hotel, Abu Dhabi - UAE Tiles can be applied to drylined walls or to the surface of lightweight partition systems. can be carried out in any type of building, either in dry areas or

More information

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide GypWall TM EXTREME GypWall EXTREME is an ultimate impact resistant partition system for use where even severe duty will not suffice. The system provides a lightweight, cost-effective, non-loadbearing partition

More information

DRYLINING PRODUCT RANGE

DRYLINING PRODUCT RANGE DRYLINING PRODUCT RANGE PAGE 2 PAGE 3 PERFORMANCE BOARDS Siniat Plasterboard drylining systems provide economic, high performance solutions to meet a wide range of building requirements. They are ideally

More information

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES 1 METAL OR TIMBER? When creating stud partitions, wall linings and suspended ceilings the traditional method of installation has been

More information

Issue date: 15th January Key changes since original publication (July 2005):

Issue date: 15th January Key changes since original publication (July 2005): Issue date: th January 007 Key changes since original publication (July 00): January 007 Page 7 MultiBoard detail (G00) deleted from 0 minute specs in Table. Page 7 Floor depth column deleted from table.

More information

promise Comprises only the highest quality components, designed to work individually and together to deliver the specified level of performance.

promise Comprises only the highest quality components, designed to work individually and together to deliver the specified level of performance. Trade Catalogue 2012 SpecSure Contacts SpecSure SpecSure is a unique 'off the shelf' warranty to end users that confirms British Gypsum proprietary systems will perform to the parameters published in our

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information

GypWall Secure Systems

GypWall Secure Systems GypWall Secure Systems This is a lightweight, non load bearing security wall system, offering high resistance to determined attack. Key facts Minimal wall thickness Tested in accordance with SANS 10177:2

More information

C07. S03. P02 P24 DriLyner basic, tl, mf, rf

C07. S03. P02 P24 DriLyner basic, tl, mf, rf ! This section includes updated information, added since it was first published in December 05. Last updated 9/0/08 C07. S0. P0 P DriLyner basic, tl, mf, rf Including C07. S0. P0 P0 Linings introduction

More information

Loadbearing timber joist floors

Loadbearing timber joist floors C06 Floors and ceilings Internal and separating floor systems Timber joists are widely used within internal floor and separating floor construction, both in residential and coercial applications. Our range

More information

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

The Revolutionary New Plasterboard TIMBER FRAME GUIDE The Revolutionary New Plasterboard TIMBER FRAME GUIDE 2 HABITO BOARD is a stronger plasterboard that provides enhanced sound insulation, extra durability and for the first time, direct fixing capability.

More information

Sheathing Board Xtra protection, built in.

Sheathing Board Xtra protection, built in. Sheathing Board Xtra protection, built in. Introducing Glasroc X Sheathing Board Glasroc X is a high performance sheathing board which provides up to 6 months weather protection as certified by the British

More information

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL.

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL. GypLyner UNIVERSAL GypLyner (Ceilings) Concealed grid ceiling lining system GypLyner ceiling is a general purpose ceiling lining system suitable for most internal applications. It is used in all types

More information

Rigidur h for off-site applications Product Data Sheet

Rigidur h for off-site applications Product Data Sheet Rigidur h for off-site applications Product Data Sheet Introduction Rigidur h can be used in partition and ceiling systems to give increased rigidity and durability, with excellent acoustic performance,

More information

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall -

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall - ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction - ShaftWall 9/0/08 FireWall 9/0/08 GypWall curve 6//06 GypWall secure 9/0/08

More information

Plasterboard selector guide Dedicated to plasterboard

Plasterboard selector guide Dedicated to plasterboard GYPROC Plasterboard selector guide Dedicated to plasterboard Dedicated to Plasterboard British Gypsum manufactured the first plasterboard in the UK over 90 years ago. Since then, we have developed this

More information

22 The Lowry Centre, Salford

22 The Lowry Centre, Salford The Lowry Centre, Salford Glasroc F fire protection solutions Glasroc F board products FireCase GypWall CLASSIC 7 FireWall 88 Timber stud 9 GypWall CURVE 96 GypWall SECURE 99 BlastWall 0 FlameLyner 0 Cavity

More information

Acoustic ceilings. Creating perfect living spaces. Technical Advice Centre Tel:

Acoustic ceilings. Creating perfect living spaces. Technical Advice Centre Tel: Acoustic ceilings 216 Technical Advice Centre Tel: 0844 800 1991 Acoustic ceilings A ceiling is unlike any other area within a building. The look you create will remain untouched, uncluttered and unaffected

More information

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment C08 Finishes to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment All our systems are covered by SpecSure when using genuine Gyproc and Isover

More information

C05. S02. P02 P30 ShaftWall

C05. S02. P02 P30 ShaftWall ! This section includes updated information, added since it was first published in December 0. Last updated 0//0 C0. S0. P0 P0 Including C0. S0. P0 Specialist partitions introduction C0 Specialist partitions

More information

The ultimate sound insulating wall system

The ultimate sound insulating wall system C0 Partitions The ultimate sound insulating wall system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing, twin-frame high performance wall system

More information

December 2011 OFF-SITE. Off-site solutions

December 2011 OFF-SITE. Off-site solutions December 2011 Off-site solutions Why choose British Gypsum? Off-site manufacturing demands product that is proven, consistent, reliable and robust. British Gypsum has a package of products and services

More information

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements ! This section includes updated information, added since it was first published in ecember 05. Section Last updated Introduction - FireCase 0//07 GypLyner encase /05/07 Introduction Steel encasements C03

More information

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise SOUND SOLUTIONS FOR YOUR HOME Controlling the volume of everyday living How to solve a problem you have with noise How to reduce unwanted noise within your home Improve your home s sound insulation for

More information

FireCase. Frameless structural steel encasement system. FireCase.

FireCase. Frameless structural steel encasement system. FireCase. Frameless structural steel encasement system frameless encasement system provides a high quality cladding to structural steel, and offers up to 10 minutes fire protection. The system affords protection

More information

Acoustic and thermal insulation solution guide isover.co.uk

Acoustic and thermal insulation solution guide isover.co.uk THE INSULATION HANDBOOK Acoustic and thermal insulation solution guide isover.co.uk Applications Pitched Roof - Joist Level Internal Floors Ground Floors Airtightness and Moisture Management Separating

More information

Rigidur H for commercial applications

Rigidur H for commercial applications for coercial applications Product data sheet Introduction Characteristics is a gypsum fibreboard which combines gypsum, cellulose fibres from recycled paper, and water, to form a dense sheet material that

More information

FireWall. High performance fire-resistant wall system. FireWall.

FireWall. High performance fire-resistant wall system. FireWall. FireWall FireWall High performance fire-resistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

Plasterboard accessories - Products

Plasterboard accessories - Products www.british-gypsum.com Gyproc plasterboard accessories The Gyproc range of accessories includes everything you need to finish plasterboard linings and partitions ready for decoration. Every stage is catered

More information

C06. S02. P02 P22 CasoLine mf

C06. S02. P02 P22 CasoLine mf ! This section includes updated information, added since it was first published in December 0. Last updated 6//06 C06. S0. P0 P CasoLine mf Including C06. S0. P0 P08 Floors and ceilings introduction C06

More information

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness, Wall Linings Our versatile range of wall lining systems makes it easy to produce a high-quality, high-performance finished wall regardless of the background. Whether your priority is acoustic control,

More information

GypLyner framed structural steel encasement system

GypLyner framed structural steel encasement system GypLyner framed structural steel encasement system is a steel encasement system which provides a rapid method of cladding structural steel sections to provide up to 10 minutes fire resistance. The system

More information

Background & theory. Leeds Unite Student accommodation. Image courtesy of Shepherd Construction.

Background & theory. Leeds Unite Student accommodation. Image courtesy of Shepherd Construction. 1. Background & theory Background & theory Leeds Unite Student accommodation. Image courtesy of Shepherd Construction. Contents Section overview Introduction 6 SpecSure 7 Acoustics 8-11 Fire 12-14 Sustainability

More information

CO9. Sound absorbing solutions C09

CO9. Sound absorbing solutions C09 ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction /0/06 CasoLine mf /05/07 CasoLine curve /05/07 GypLyner universal /05/07

More information

Semi-exposed soffits. Thermal lining system for semi-exposed soffits. Semi-exposed soffits.

Semi-exposed soffits. Thermal lining system for semi-exposed soffits. Semi-exposed soffits. Semi-exposed soffits Semi-exposed soffits Thermal lining system for semi-exposed soffits SoffitLine combines the benefits of Gyproc MultiBoard with thermally efficient phenolic foam insulation. It can

More information

WALLS GYPWALL FIRESTOP WALLS 25 GYPWALL FIRESTOP KEY FACTS

WALLS GYPWALL FIRESTOP WALLS 25 GYPWALL FIRESTOP KEY FACTS WALLS GYPWALL FIRESTOP Is a non-load bearing high performance fire resistance system providing a fire rating of up to 60 minutes. Used in retail environments, storage areas and residential applications.

More information

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION WITH PLASTERBOARD GTEC MOISTURE AND VAPOUR BOARD 3 MOISTURE AND HUMIDITY Kitchens, utility rooms and cloak rooms are areas of high humidity, modern

More information

Gyproc FibaTape range

Gyproc FibaTape range Gyproc FibaTape range High performance self-adhesive drywall joint tapes Gyproc FibaTape Selector Application Board edge Standard environment Humid/cold environment Dry rooms Wet rooms All rooms Wall Ceiling

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

CasoLine mf. Concealed monolithic metal frame suspended ceiling system

CasoLine mf. Concealed monolithic metal frame suspended ceiling system C0 Floors and ceilings Concealed monolithic metal frame suspended ceiling system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a suspended ceiling system suitable

More information

TIMBER FRAME HOUSING SOLUTIONS

TIMBER FRAME HOUSING SOLUTIONS TIMBER FRAME HOUSING SOLUTIONS Complete range of acoustic and thermal insulation for timber frame housing isover.co.uk Introduction The timber frame market continues to grow within the UK. Key drivers

More information

ShaftWall. Shaft and duct encasement system. ShaftWall.

ShaftWall. Shaft and duct encasement system. ShaftWall. ShaftWall ShaftWall Shaft and duct encasement system ShaftWall provides a lightweight, non-loadbearing fire-resistant structure to protect elements within the service cores of modern fast-track developments.

More information