1 Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the Plumbing Code shall apply to: a. every plumbing installation b. alterations and repairs c. replacements d. all of the above 3. The provisions of the Plumbing Code shall NOT apply to: a. Gas-fired water heaters b. Water heater venting systems c. Fuel gas piping d. All of the above 2012 NC Plumbing Code Level 3 Page 1 of 14 Revised: 10/2016
2 Chapter 1 Answer Key 1. C D D NC Plumbing Code Level 3 Page 2 of 14 Revised: 10/2016
3 Chapter 8 Worksheet 1. A restaurant has an indirect waste line discharging into a floor drain located in a closet and an additional indirect waste is discharged into a floor drain located in a toilet room. Which of the following makes this a code violation? a. waste receptors shall not be installed in a closet b. waste receptors shall not be installed in a toilet room c. Both A and B d. None of the above 2. What is the minimum air gap required by the code for a 2 inch drain? a. 2 b. 3 c. 4 d Indirect waste pipe exceeding inches horizontal/developed or inches in total developed lengths shall be trapped. a. 18, 24 b. 24, 48 c. 36, 48 d. 30, The outlet of the laundry tray shall be a maximum horizontal distance of inches from the standpipe trap. a. 18 b. 24 c. 30 d NC Plumbing Code Level 3 Page 3 of 14 Revised: 10/2016
4 5. The vertical standpipe inlet for a washing machine drain to the trap weir shall be a minimum of inches? a. 24 b. 18 c. 12 d NC Plumbing Code Level 3 Page 4 of 14 Revised: 10/2016
5 Chapter 8 Answer Key 1. C C B C B NC Plumbing Code Level 3 Page 5 of 14 Revised: 10/2016
6 Chapter 9 Worksheet 1. On the lower floors of multi- story buildings, when wet venting, with 7 bathtubs, what size vent stack is required? a. 2 b. 2½ c. 3 d With vertical combination waste and wet venting, a 4 diameter stack with a maximum length of 100 would be required for 6 public use water closets. a. True b. False 3. A 4 diameter drain having 300 fixture units, 60 foot long vent, requires a vent stack of. a. 2 b. 2½ c. 3 d Can the waste pipe from one or two lavatories be used as a wet vent for one or two bathtubs or shower on the top floor of a multi-story building? a. Yes b. No 5. A domestic bathtub has a 1½ p-trap and a 2 waste arm. What is the maximum length of this trap arm to its vent terminal? a. 5 feet b. 8 feet c. 6 feet d. 10 feet 2012 NC Plumbing Code Level 3 Page 6 of 14 Revised: 10/2016
7 6. A multi-story apartment building is using wet vent tubs and shower on all floors. there are 6 tubs and 5 showers. The minimum size vent stack is? a. 3 inches b. 2 inches c. 2½ inches d. 4 inches 7. A 4 inch soil stack has 250 dfu connected to it. This stack is vented with a 3 stack vent. What would be the maximum permitted length of this stack vent? a. 170 feet b. 260 feet c. 70 feet d. 250 feet 8. A 4 soil stack receives the discharge of 180 dfu. This soil stack is stack vented to the open air, but this vent is not the main vent for the building. The stack vent portion is 36 feet, what is its minimum size? a. 1½ inches b. 2 inches c. 2½ inches d. 3 inches 9. A 5 inch horizontal branch is required to have a relief vent. The relief vent is serving as a relief for 96 dfu. The developed length of this vent is 24 feet. What is the minimum allowed size of this relief vent? a. 1½ inches b. 2 inches c. 2½ inches d. 3 inches 2012 NC Plumbing Code Level 3 Page 7 of 14 Revised: 10/2016
8 Chapter 9 Answer Key 1. C T B C T B C T D T A T C T C T NC Plumbing Code Level 3 Page 8 of 14 Revised: 10/2016
9 Chapter 10 Worksheet 1. Which of the following is an approved trap? a. S-trap b. Bell-trap c. P-trap d. Crown-trap 2. Sand and similar interceptors for heavy solids shall have a water seal of not less than inches. a. 1 b. 2 c. 4 d Each interceptor shall be. a. properly vented b. at least 3 inches in diameter c. galvanized d. designed to become air bound 4. Traps shall have a water seal of not more than inches and not less than inches. a. 3 & 2 b. 4 & 1 c. 2 & 4 d. 4 & 2 5. An intercepting device shall prevent the passage of solids of inch and larger. a. ½ b. ¼ c. ¾ d NC Plumbing Code Level 3 Page 9 of 14 Revised: 10/2016
10 6. Interceptors shall be maintained in efficient operating condition by removal of accumulated grease. a. annual b. semi-annual c. monthly d. periodic 7. A combination plumbing fixture may be installed on one trap, if one compartment is not more than inches deeper than the other and the waste outlets are not more than inches apart. a. 6 & 30 b. 12 & 24 c. 6 & 18 d. 4 & NC Plumbing Code Level 3 Page 10 of 14 Revised: 10/2016
11 Chapter 10 Answer Key 1. C D A D A D A # NC Plumbing Code Level 3 Page 11 of 14 Revised: 10/2016
12 Chapter 11 Worksheet 1. When roof drains are provided they shall have strainers extending not less than inches above the surface of the roof immediately adjacent to the roof drain. a. 3 b. 4 c. 5 d What is the maximum projected roof area that a 4 inch vertical leader can handle with a 4 inches per hour rainfall? a. 18,400 square feet b. 9,200 square feet c. 6,130 square feet d. 4,600 square feet 3. A roof has an area of 4,600 square feet. What is the minimum size horizontal drain required if it has 1/4 per foot fall and 4 inches per hour rainfall? a. 4 b. 5 c. 6 d Secondary roof drain systems are sized according to what rain flow rate? a. 100 year, 15 minute precipitation b. 100 year, 60 minute precipitation c. 60 year, 15 minute precipitation d. 60 year, 60 minute precipitation 5. A receptacle designed to collect surface or rain water from an open area is a a. Conductor b. Leader c. Backwater device d. Area drain 2012 NC Plumbing Code Level 3 Page 12 of 14 Revised: 10/2016
13 6. Which of the following shall not be connected to a storm drain? a. Roof leaders b. Floor drains c. Area drains d. Roof conductors 2012 NC Plumbing Code Level 3 Page 13 of 14 Revised: 10/2016
14 Chapter 11 Answer Key 1. B D B A F A 5. D B NC Plumbing Code Level 3 Page 14 of 14 Revised: 10/2016
READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X
CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 9 - VENTS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
More informationGRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS
City of Azusa Building & Safety Department 213 E. Foothill Blvd. Azusa, CA 91702-1395 (626) 812-5234 Fax: (626) 334-5464 GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS A. GRAYWATER SYSTEMS Under State regulations,
More informationGRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS
INFORMATION BULLETIN / PUBLIC - PLUMBING CODE REFERENCE NO.: LAMC 94.1502.0 Effective: 01-01-2017 DOCUMENT NO.: P/PC 2017-012 Revised: Previously Issued As: P/PC 20014-012 GRAY WATER SYSTEMS FOR RESIDENTIAL
More informationREAD ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX C - ALTERNATE PLUMBING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority
More information1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and Highlights
1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and s These1 Exam Prep Tabs are based on the Florida Building Code - Plumbing 2014. Each 1 Exam Prep tabs sheet has five rows of tabs. Start with
More informationCopyright 2017, ProVent Systems Inc., All Rights Reserved
Copyright 2017, ProVent Systems Inc., All Rights Reserved Introduction to ProVent Systems A PVC Plastic Single Stack Waste and Vent System The ProVent System is a plumbing engineered single stack system
More information6857 INTERNET TEST PLMB30
Instructions: www.garyklinka.com 1. Print these pages. 2. Circle the correct answers and transfer to the answer sheet on the last page. 3. Page down to the last page for the verification forms and mailing
More informationGRAYWATER STANDARD PLAN For Simple Residential System
(Based on 203 California Plumbing Code Chapter 6) Project Address: Permit Number: Scope: This Plan applies only to simple residential systems meeting all the following criteria: Graywater discharge is
More informationTable of Contents Rules Concerning Uniform Plumbing Code
Table of Contents 07.02.06 - Rules Concerning Uniform Plumbing Code 000. Legal Authority.... 2 001. Title And Scope.... 2 002. Written Interpretations.... 2 003. Administrative Appeals.... 2 004. -- 010.
More informationAmendments to the 2012 International Plumbing Code
Amendments to the 2012 International Plumbing Code The following sections, paragraphs, and sentences of the 2012 International Plumbing Code are hereby amended as follows: Standard type is text from the
More informationInternational Plumbing Code 2006 Study Guide
006 Study Guide 1 Unfired hot water storage tanks shall be insulated so that heat loss is limited to a maximum of British thermal units per hour (Btu/h) per square foot (7 W/m) of external tank surface
More informationLand Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents
Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions
More information3. Sanitary Plumbing Single Stack System
3. Sanitary Plumbing Single Stack System On completion of this section, students should be able to: Design, install and develop bills of quantities for the Single Stack Systems for domestic, commercial
More informationOntario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12
Ontario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12 Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the
More informationTypical Finished Basement Details
Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details
More information2012 International Plumbing Code. Exhibit D
Exhibit D 2012 International Plumbing Code The following sections, paragraphs, and sentences of the 2012 International Plumbing Code are hereby amended as follows: Standard type is text from the IPC. Underlined
More informationReview the section Preparing for work, then complete the following.
CHAPTER 4: PLANNING THE LAYOUT FOR A RESIDENTIAL EXTERNAL SANITARY DRAINAGE SYSTEM 105 WORKSHEET 1 Student name: Enrolment year: Class code: Competency name/number: To be completed by teachers Satisfactory
More informationChapter 2 Definitions. Chapter 2 Definitions COMBINATION WASTE AND VENT SYSTEM.
BEDROOM. A room that can be used for sleeping and that: a. For site-built s has a minimum of 70 square feet (6.50 m 2 ) of conditioned space; b. For manufactured homes is constructed according to the standards
More informationSTORM DRAINAGE CHAPTER 11
CHAPTER STORM DRAINAGE SECTION 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage, except in one- and two-family dwellings.
More informationREQUEST FOR TECHNICAL CHANGE
REQUEST FOR TECHNICAL CHANGE AGENCY: NC Building Code Council RULE CITATION: All Rules Submitted DEADLINE FOR RECEIPT: Friday, August 12, 2016 NOTE WELL: This request when viewed on computer extends several
More informationSTORM DRAINAGE CHAPTER 11
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
More informationA. This Section includes the following sanitary drainage piping specialties:
Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More information101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)
City of York Qdot Engineering 101 S. George St 116 E Gas Ave York, PA 17405 York, PA 17405 (717) 849-2329 (717) 744-8315 INSPECTION CHECKLIST Residential Plumbing Rough-In April 2011 2009 Codes This checklist
More informationAmendments to the 2006 International Plumbing Code
Amendments to the 2006 International Plumbing Code Table of Contents, Chapter 7, Section 714; change to read as follows: Section 714 Engineered Drainage Design................... 65 Chapter 1, Administration
More informationFairfax County, Virginia
Fairfax County, Virginia Typical Finished Basement Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Wall Construction... 3 Floor/ceiling
More informationHolding tank Interceptor Leaching Leaching bed Leaching bed fill Loading rate Pail privy Percolation time Portable privy Potable Pressurized
Glossary of Terms Absorption trench Artesian groundwater As constructed plans Basement Bathroom group Building area Building sewer Clean water Clear water waste Distribution box Distribution pipe Drainage
More information2015 IPC Design, Installation and Inspection Principles IPC Design, Installation and Inspection Principles
Description 2015 IPC Design, Installation and Inspection Principles Based on the 2015 International Plumbing Code (IPC ) The 2015 International Plumbing Code (IPC ) continues to emphasize both prescriptive
More informationCharter Township of Raisin
Charter Township of Raisin Authority: AC. 230 of 1972 As Amended PLUMBING PERMIT APPLICATION Application date: Completion: Installation shall not 5525 Occidental Hwy. Permit # be started until an application
More informationNOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING
1 1 1 1 1 1 1 1 0 1 0 1 NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING NORTH CAROLINA BUILDING CODE COUNCIL Notice of Rule-making Proceedings is hereby given by NC Building Code Council in accordance
More informationSUPPLEMENTAL 2011 PLUMBING CORRECTION SHEET FOR HIGH-RISES
SUPPLEMENTAL 2011 PLUMBIN CORRECTION SHEET FOR HIH-RISES 2010 CPC ENERAL REQUIREMENTS A1. Plans shall bear the registration or license number and signature of an architect, contractor, or engineer, registered
More informationSECTION PLUMBING PIPING SYSTEM
SECTION 15410 - PLUMBING PIPING SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, are a part of this Section. 1.02 SUMMARY
More information3.1 General Requirements:
3. CONSTRUCTION MODIFICATIONS TO LIMIT THE DISCHARGE OF HARMFUL WASTES INTO THE DISTRICT S FACILITIES: GREASE INTERCEPTORS/TRAPS AND SAND/OIL INTERCEPTORS/TRAPS 3.1 General Requirements: 3.1.1 Policy:
More information2006 International Plumbing Code
2006 International Plumbing Code First Printing: January 2006 Second Printing: March 2006 ISBN-13: 978-1-58001-259-1 (soft-cover) ISBN-10: 1-58001-259-0 (soft-cover) ISBN-13: 978-1-58001-258-4 (loose-leaf)
More informationWater Service Inspection Checklist
Water Service Piping Inspection 4 ;ection P2902 Protection of Potable Water Supply Section P2903 Water-supply System Section P2906 Materials, Joints and Connections Section P2907 Changes in Direction Section
More informationChapter DRAFT - PLUMBING CODE* (Current working draft of Juneau Building Code Advisory Committee 10/24/ unadopted)
Chapter 19.05 DRAFT - PLUMBING CODE* (Current working draft of Juneau Building Code Advisory Committee 10/24/2003 - unadopted) * Charter References: Technical code adoption, 5.5. Cross References: General
More informationPREPARING RESIDENTIAL PROPERTY FORTHE HOUSING HABITABILITY INSPECTION
CITY OF LOS ANGELES HOUSING DEPARTMENT HABITABILITY INSPECTION PROGRAM CODE ENFORCEMENT UNIT 3550 Wilshire Boulevard, 15 th Floor Los Angeles, CA 90010 PREPARING RESIDENTIAL PROPERTY FORTHE HOUSING HABITABILITY
More informationREGISTRATION EXAMINATION, november 2015 LICENSED PLUMBER. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, november 05 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed
More informationCity of West Allis W Greenfield Ave Room 222 West Allis, WI Phone: (414) Fax: (414) Plumbing Inspector: Mike Romens
City of West Allis 7525 W Greenfield Ave Room 222 West Allis, WI 53214 Phone: (414) 302 8400 Fax: (414) 302 8402 Plumbing Inspector: Mike Romens Direct: (414) 302 8419 Office hours: 8:00am 9:00am & 1:00pm
More informationRecommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Plumbing Code
More informationSOUTHERN NEVADA PROPOSED AMENDMENTS TO THE 2012 UNIFORM PLUMBING CODE PLUMBING/MECHANICAL CODE COMMITTEE SEPTEMBER 07, 2012
SOUTHERN NEVADA PROPOSED AMENDMENTS TO THE 2012 UNIFORM PLUMBING CODE PLUMBING/MECHANICAL CODE COMMITTEE SEPTEMBER 07, 2012 Page 1 of 44 Rev.04.21.09 PREFACE This document was developed by the Southern
More informationCommon Plan Review Rejection Reasons
Common Plan Review Rejection Reasons Submitted plans must contain sufficient information for plan reviewers to be able to verify that the proposed construction complies with the Virginia Uniform Statewide
More informationfor plumbing regulations.
CHAPTER 30 SANITARY DRAINAGE SECTION P3001 GENERAL P3001.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. Plumbing
More informationPORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2010 California Plumbing Codes
2010 PORT OF SAN FRANCISCO PLUMBING CODE Based on the 2010 California Plumbing Codes 2010 Port of San Francisco Plumbing Code The complete 2010 Port of San Francisco Plumbing Code adopts and amends the
More informationThe following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.
The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. You can complete the test by printing a hard copy, or
More informationA. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationPLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2017 LAPC
PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2017 LAPC This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. Section:
More informationCommon Plan Review Rejection Reasons
(CPHD) (ISD) Common Plan Review Rejection Reasons Submitted plans must contain sufficient information for plan reviewers to be able to verify that the proposed construction complies with the Virginia Uniform
More informationGRAY WATER RECYCLING SYSTEMS
GRAY WATER RECYCLING SYSTEMS Note: Section P2601.2 of the International Residential Code requires all plumbing fixtures that receive water or waste to discharge to the sanitary drainage system of the structure.
More informationMunicipal Code of Chicago CHAPTER PLUMBING* Article 1. Administration Department of Water Management requirements.
Municipal Code of Chicago CHAPTER 18-29 PLUMBING* * Editor's note - Chapter 18-29, Water Service Charges and Plumbing Requirements, was added by Coun. J. 3-28-01, p. 55444, 1. Coun. J. 11-21-17, p. 61913,
More informationSOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM PLUMBING CODE
SOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM PLUMBING CODE PREFACE This document was developed by the Southern Nevada Building Officials Uniform Plumbing Code Committee and presents recommended amendments
More informationPulaski County, Virginia
Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3
More informationSANITARY DRAINAGE CHAPTER 30
CHAPTER 30 SANITARY DRAINAGE SECTION P3001 GENERAL P3001.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. Plumbing
More informationErrata for the 2003 Uniform Plumbing Code Study Guide (5th Printing)
Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing) The following is a list of changes that we found after the fifth printing of the 2003 Uniform Plumbing Code Study Guide. These changes
More informationAccessible Toilet and Bathing Rooms
Accessible Toilet and Bathing Rooms Building & Fire Safety Division Yakima County Public Services This brochure is for illustration purpose only. It is NOT a complete section of the referenced codes, nor
More informationGRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS
Building and Safety Division - Public Information County of Ventura Resource Management Agency http://www.ventura.org/ build_safe Main Office 800 S. Victoria Ave, Ventura, CA. 93009 805-654-2771 East County
More informationA. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.
PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More information2015 UPC Chapter 2 Definitions Part 1 RV 11/8/16
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationPORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2016 California Plumbing Code
2016 PORT OF SAN FRANCISCO PLUMBING CODE Based on the 2016 California Plumbing Code The complete 2016 Port of San Francisco Plumbing Code adopts and amends the 2016 edition of the California Plumbing Code.
More informationCHAPTER 2 DEFINITIONS CHAPTER 3 GENERAL REGULATIONS
CHAPTER 2 DEFINITIONS 1) (Q) While inspecting a lab set up for acid waste and vent piping in a medical office building the inspector finds the acid waste piping system installed without the minimum required
More informationChapter 3: General Regulations
Chapter 3: General Regulations General Comments The content of Chapter 3 is often referred to as miscellaneous, rather than general regulations. Chapter 3 received that label because it is the only chapter
More informationREQUEST FOR DEVIATION WATER AND WASTEWATER SYSTEM STANDARD SPECIFICATIONS
REQUEST FOR DEVIATION WATER AND WASTEWATER SYSTEM STANDARD SPECIFICATIONS PRODUCT NAME: PRODUCT DESCRIPTION: DISTRIBUTOR'S NAME: DISTRIBUTOR'S ADDRESS: DISTRIBUTOR'S PHONE NUMBER: MANUFACTURER S NAME:
More information1 Exam Prep Chapter 64E -6 Questions and Answers
1 Exam Prep Chapter 64E -6 Questions and Answers Part One 1. According to Florida Rules: Chapter 64E-6, if building construction has commenced, for how many additional days past the eighteen month expiration
More informationICC Plumbing Update. St Louis Missouri ASPE Chapter March 5, 2013
ICC Plumbing Update St Louis Missouri ASPE Chapter March 5, 2013 Agenda Welcome & Introductions Introduction to the ICC Code Development Process Significant Changes in the 2015 IPC PERC Phase II Testing
More informationLand Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents
Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions
More informationAPPLICATION FOR GRAYWATER IRRIGATION SYSTEM PERMIT SIMPLE RESIDENTIAL GRAVITY SYSTEMS, NO STORAGE
APPLICATION FOR GRAYWATER IRRIGATION SYSTEM PERMIT SIMPLE RESIDENTIAL GRAVITY SYSTEMS, NO STORAGE Please read the California Plumbing Code Chapter 16A-1 Design Requirements before completing this form.
More informationSeptic Permit Application
BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Tel.: 519 845-5420 Toll Free: 1-866-324-6912 Fax: 519 845-3817 www.lambtononline.ca Septic Permit Application a) This application
More informationA. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.
SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationTOWNSHIP OF UPPER DEERFIELD
TOWNSHIP OF UPPER DEERFIELD ORDINANCE NO. AN ORDINANCE TO AMEND CHAPTER 165 OF THE CODE OF THE TOWNSHIP OF UPPER DEERFIELD ENTITLED: "CONSTRUCTION CODE ENFORCEMENT," SETTING FEES FOR CONSTRUCTION PERMITS.
More informationCHAPTER 7 SANITARY DRAINAGE SYSTEMS
PlumbingCode06_ch07 5/29/06 8:13 AM Page 1 CHAPTER 7 SANITARY DRAINAGE SYSTEMS Drainage systems intimidate many people. When these people look at their codebooks, they see charts and math requirements
More informationCity of Muskogee Pollution Control Department POLICY STATEMENT FOR GREASE AND OIL CONTROL
POLICY STATEMENT FOR GREASE AND OIL CONTROL Section 1: Introduction - In an effort to curb sanitary overflows (SSOs) from grease accumulation in its sanitary sewer main all nonresidential facilities connected
More informationTOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX
TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ 08014 856-467-3626--- FAX 856-467-9260 Application for Certificate of Occupancy for Change of Occupancy Pursuant to Chapter 119 of the Township
More informationProposed Revisions ******
ALLEGHENY COUNTY HEALTH DEPARTMENT RULES & REGULATIONS ARTICLE XV PLUMBING AND BUILDING DRAINAGE Proposed Revisions CHAPTER 1 ADMINISTRATION. SECTION 101 GENERAL. 101.1 Title. These regulations shall be
More informationCITY OF ANDERSON BUILDING AND CODES 601 South Main Street
CITY OF ANDERSON BUILDING AND CODES 601 South Main Street Plan Review Notes (STREET ADDRESS) ANDERSON, SC Plan Review Number: Building Plans prepared by: Plans Signed by: Project Name: Plans Received:
More informationApplication For Graywater Irrigation System Permit
Please read the California Plumbing Code Chapter 16 Design Requirements before completing this form. Assessor s Parcel No.: 1. Project address: 2. Owners name and contact info: 3. Designer s Name License
More informationCONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA
AMERICAN PLUMBING INSTITUTE 2015 33 CONTINUING EDUCATION PO Box 31131 Spokane, WA 99223-3018 www.apiceu.com 2009 UPC Definitions Code Course 4 hours Course # ID09143 (CODE) DISCLAIMER NOTE: This course
More informationInternational Plumbing Code (IPC), 2012 Edition with 2014 Georgia State Amendments
110-11-1-.26 International Plumbing Code (IPC), 2012 Edition with 2014 Georgia State Amendments Georgia State Amendments to the International Plumbing Code (2012 Edition) Georgia Department of Community
More informationWATER & SEWER SERVICES
WATER/SEWER ENGINEERING SECTION PHONE (703) 228-3677 WATER & SEWER SERVICES INFORMATION & APPLICATION PACKAGE REVISED MAY 2018 1 MAY 2018 Dear Customer: Thank you for taking the time to read this information
More informationCALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 11 - STORM DRAINAGE
CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 11 - STORM DRAINAGE Adopting Agency BSC SFM HCD DSA OSHPD CSA DPH AGR DWR CA 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt Entire Chapter X X Adopt Entire Chapter
More informationDEVICES AND LUMINAIRES
CHAPTER 40 DEVICES AND LUMINAIRES SECTION E4001 SWITCHES E4001.1 Rating and application of snap switches. General-use snap switches shall be used within their ratings and shall control only the following
More informationStudent Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:
SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:
SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing
More informationCounty of Yolo Development Services Building Inspection Division
County of Yolo Development Services Building Inspection Division 292 W. Beamer Street Woodland, CA. 95695 www.yolocounty.org (530) 666-8775 Mechanical Plan Review Comments Plan Review No. Owners Name Job
More informationCity of Rohnert Park When Permits are Required
Permits are required as provided below based on the applicable code governing the trades involved in a building project. In some instances more than one trade may be involved in a project so be sure to
More informationCONTINUED ON FOLLOWING PAGE
Date Description of Change Pages / Sections Modified ID 08/05/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This standard refers to the following plumbing specialties. A. Drains, B. Hydrant and Hose
More informationDIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM
DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a
More informationRENTAL INSPECTION CHECKLIST. Helpful Definitions: Egress: the free and unobstructed access to the exterior of a habitable space.
CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street, Room 201, Manassas, VA 20110 P.O. Box 560 Manassas, VA 20108 Phone: 703-257-8278 Fax: 703-257-5831
More informationAdvanced Water Supply and Distribution
Advanced Water Supply and Distribution Instructor Otto Vinas Course # BCAIB CILB Location Nova Southeastern University Hour (s) One Potable Water Required 602.2 Only potable water shall be supplied to
More informationSection 8.7 Building Storm Drainage Systems
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Building Storm Drainage Systems 8.7.0. General Design Requirements
More informationCRAFTSMAN EXAMINATION, NOVEMBER 2008 PLUMBING ANSWER SCHEDULE
No. 9195 CRAFTSMAN EXAMINATION, NOVEMBER 2008 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2008. All rights reserved. No part of this publication may be reproduced by any means
More informationTypical Finished Basement Details
Town of Merrimac, Ma Typical Finished Basement Details Based on the 2009 International Residential Code Finished basements must be constructed in conformance with this document. For requirements, details
More informationCOMMERCIAL PROJECT PLAN REVIEW PROCESS
COMMERCIAL PROJECT PLAN REVIEW PROCESS Complete construction documents, which contain all of the required information will speed the plan review process. The following checklist establishes minimum guidelines
More information2018 IRC Sections R303 through R310 Building Planning II
Study Session 3 2018 IRC Sections R303 through R310 Building Planning II OBJECTIVE: REFERENCE: KEY POINTS: To develop an understanding of the health and safety criteria of the code, including light and
More informationCHAPTER 15 PLUMBING CODE
CHAPTER 15 PLUMBING CODE 15.01 State Regulations Adopted 15.02 Plumbing Defined 15.03 Plumbing Inspection 15.04 Plumbing Permits 15.05 Fees 15.06 Plumbers To Be Licensed 15.07 Inspection of Work 15.08
More informationCHAPTER 11 MOBILE HOME PARKS
CHAPTER 11 MOBILE HOME PARKS ARTICLE A Section 11-1 GENERAL PROVISIONS Purpose The purpose of this Chapter is to provide for the protection and promotion of the public health by establishing regulations
More informationAN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS:
AN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS: ARTICLE ONE: Code and Appendices. That, pursuant to
More informationDEVICES AND LUMINAIRES
CHAPTER 39 DEVICES AND LUMINAIRES SECTION E3901 SWITCHES E3901.1 Rating and application of snap switches [404.14(A)]. General-use snap switches shall be used within their ratings and shall control only
More informationSANITARY SEWER BACKUP
SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides
More informationCHAPTER 11 STORM DRAINAGE Subsoil drains shall be piped to a storm Where it is not possible to convey the
CHAPTER 11 STORM DRAINAGE 1101.0 General. 1101.1 Where Required. All roofs, paved areas, yards, courts, and courtyards shall be drained into a separate storm sewer system, or into a combined sewer system
More informationCity of Edwardsville Safe Housing Program Rental Property Registration and Inspection. Rental Property Guide
City of Edwardsville Safe Housing Program Rental Property Registration and Inspection Rental Property Guide Public Works Department 200 East Park Street Edwardsville, IL 62025 Office: (618) 692-7535 Direct
More informationUniform Construction Code
Uniform Construction Code When the UCC Requires Permits and Inspections (A Zoning Certificate may be required even though the project does not require a UCC Building Permit.) As a general rule, the UCC