ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING
|
|
- Dustin Rice
- 5 years ago
- Views:
Transcription
1 ADMIN. S POST Anchor Bolts (4 Required) 1 Pole Base Plate Footing PLAN POST Chamfer on Footing ESTIMATED QUANTITIES ITEM UNIT QUANTITY Footing & Eyebolt Class M5 Concrete CU.YD. 0.5 The quantity shown above is for one Post footing and two Cable 1 Min. Embedment Length Eyebolt 1 Min. Tie Down footings. NOTE: For location of footings see Sheet No. 114 of 199 and Road Closure Gate notes on Sheet No. 112 of Threaded Anchor Bolts 3-0 (Footing Depth) 1 Min Embedment Length -0 (Footing Depth) CONCRETE FOOTINGS FOR -0 diameter ELEVATION 1-0 diameter POST FOOTING DETAIL CABLE TIE DOWN FOOTING 4428SE01
2 ADMIN. S 8 S.D. IM 29-3(89) CABLE TIE DOWN FOOTING, SEE DETAIL ON (TYP.) CABLE ATTACHMENT, SEE DETAIL B THIS GATE POST BOLT AND WASHER CLAMP CABLE 18-0 TYPE B HIGH INTENSITY FLASHING WARNING LIGHTS GATE HINGE DETAILS, SEE CABLE CONNECTION SEE DETAIL A DETAIL A ROAD CLOSED SIGN DETAIL SEE SEE FOR POST CONNECTION DETAILS. GATE STAND DETAIL SEE FOR CABLE ATTACHMENT DETAILS SEE DETAIL B THIS. SEE FOR POST FOOTING DETAILS. CLAMP CABLE HOOK TYPE 1 OBJECT MARKER (18 X 18 ) SEE INTER RAMP CLOSURE GATE (SEE FOR GATE DETAIL) CABLE TIE DOWN FOOTING, SEE DETAIL ON (TYP.) CABLE ATTACHMENT, SEE DETAIL B THIS DETAIL B GATE POST TYPE B HIGH INTENSITY FLASHING WARNING LIGHTS CABLE CONNECTION SEE DETAIL A GATE HINGE DETAILS, SEE ROAD CLOSED SIGN DETAIL SEE SEE FOR POST CONNECTION DETAILS. ROADWAY CENTERLINE GATE STAND DETAIL SEE TYPE 1 OBJECT MARKER (18 X 18 ) FOR CABLE ATTACHMENT DETAILS SEE DETAIL B THIS. SEE FOR POST FOOTING DETAILS. SEE MAINLINE INTER CLOSURE GATE (SEE FOR GATE DETAIL) 4428SE02
3 ADMIN. S 8 S.D. IM 29-3(89) SHOULDER ADDITIONAL EMBANKMENT FINISHED ROADWAY Delete these 10 sections for Ramp Gate Square Aluminum Tubing (Min. wall thickness inches) Weld all joints. HOLD BACK POST SEE of 199. GATE DETAIL (For location of gate See Sheet No. 114 of 199.) TRAFFIC FLOW 17.5 (MAINLINE) 7.5 (RAMP) MAIN GATE POST AND FOOTING -0 GATE IN THE OPEN POSITION CONTRACTOR TO PROVIDE SUFFICIENT FASTENERS AND/OR HOOKS ON THE GATE FOR STORAGE THE CABLES WHEN GATE IS IN THE OPEN POSITION. NOTES REGARDING ADDITIONAL EMBANKMENT 1. INSLOPES WILL MATCH EXISTING INSLOPES. 2. INSLOPES WILL BE RESEEDED AND MULCHED TO THE SATISFACTION THE ENGINEER. 3. EMBANKMENT WILL BE COMPACTED TO THE SATISFACTION THE ENGINEER. 4. PAYMENT FOR THIS WORK WILL BE INCIDENTAL TO OTHER ITEMS. GATE DETAIL FOR 4428SE03
4 ADMIN. S 8 S.D. IM 29-3(89) BOLTED CONNECTION (TYP.) HINGE 30 THE SIGN SHALL MEET THE REQUIREMENTS AN R11-2 ADDITIONAL HOLE FOR CLOSED POSITION 48 SIGN (MUTCD). IT MUST BE REFLECTORIZED. SIGN DETAILS (For sign location see Sheet 114 of 199) CENTER TYPE 1 OBJECT BOLTED CONNECTION (TYP.) MARKER ON VERTICAL AND HORIZONTAL TUBING NINE YELLOW 3 REFLECTORS, 18 TYPE 1 OBJECT MARKER MOUNTED SYMMETRICALLY ON A YELLOW REFLECTIVE DIAMOND PANEL TYPICAL TYPE 1 OBJECT MARKER (For sign location see Sheet 114 of 199) SIGN AND OBJECT MARKER DETAILS FOR 4428SE04
5 Post Post FED.HWY. ADMIN. S x x -0 Redwood or Treated Wood Post (Actual 3 x 3 ) Plate A to Gate weld See Bracket X x long Bolts (Field Drill) 1-0 Plate A Plate A See Bracket Y BRACKET X x long Bolts (Field Drill) 1 - Padlock -0 Square Aluminum Gate Tubing 1-0 Padlock Thick BRACKET Y PLATE A x long Lag Bolts 1 - NOTE: For location of Hold Back Post See Sheet No. 115 of 199. x x Steel Tube 5-0 Length (Galvanized) 5-0 x 5 long Bolt HOLD BACK POST FOR END VIEW FRONT VIEW 4428SE05
6 ADMIN. S Cap on Post Diameter Bar Square Aluminum Tubing (See Gate Detail) Square Aluminum Tubing Weld to Gate (8 + length) Inside Diameter Pipe Field Weld to obtain 1 Gate Clearance above Weld Diameter Bolt to Gate Tubing Roadway (Typical) Weld or Threaded Connection (Typical) Washer & Wing Nut Slot in Stand Gate Stand (made from thick Flat Aluminum) 5 Diameter Pipe -0 Long (Standard Weight Pipe) Welded Connection x 3 Square Aluminum Base GATE STAND DETAIL NOTE: Gate must set level across the Road (For location of gate stand see Sheet No. 114 of 199) GATE HINGE DETAIL (For location of gate hinge see Sheet No. 114 of 199) MISCELLANEOUS DETAILS FOR 4428SE06
7 ADMIN. S POST Anchor Bolts (4 Required) 1 Pole Base Plate Footing PLAN Aluminum Torque Limiting Nut or Heavy Hex Nut 5 Diameter Pipe (Standard Weight) Aluminum Torque Limiting Nut Welded Connection x O.D. Washer Pole Base Plate O.D. Washer 1 Diameter Threaded Stainless Steel Stud Aluminum Die Cast Coupling Cover Assembly 1 Diameter Anchor Bolt Concrete Footing GATE POST BREAKAWAY DETAILS FOR ELEVATION (For location of Breakaway Gate Post see Sheet No. 114 of 199) 4428SE07
CITY OF FARGO SPECIFICATIONS SIGNING
SIGNING PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of furnishing all labor, material and accessories necessary to complete
More informationCITY OF FARGO SPECIFICATIONS SIGNING
SECTION 4300 SIGNING PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of furnishing all labor, material and accessories necessary
More informationITEM 555 CHAIN LINK FENCING
ITEM 555 AFTER MARCH 1, 2012 CHAIN LINK FENCING 555.1 Description. This item shall govern for furnishing the quantities of chain link fencing and gates as shown on the plans, including all posts, bracing
More informationKANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION
Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION Delete SECTION 812 and replace with the following: SECTION 812 PERMANENT SIGNING 812.1 DESCRIPTION
More informationCONTRACT PROVISIONS. 1. The Contract will become effective beginning July 1, 2014 and will expire on July 1, 2015.
CONTRACT PROVISIONS 1. The Contract will become effective beginning July 1, 2014 and will expire on July 1, 2015. 2. Guardrail repairs will be limited to Interstate and State Highways located in the Aberdeen
More informationFitTech UP166F CHEST PRESS (FOOTING) UP166I CHEST PREES (IN GROUND) UP166S CHEST PRESS (SURFACE)
CHEST PRESS BASE COVER DESCRIPTION FOOTBUCK WELD ASSEMBLY HARDWARE COMPLETE HARDWARE COMPLETE HARDWARE COMPLETE /" ANCHOR ROD 3/" x " HEX HEAD CAP SCREW 3/" WEDGE ANCHOR 3/" ANCHOR BOLT 3/" FLATWASHER
More informationSTANDARDIZED STRUCTURES
Q, QH & QL TOWERS 16.1 Q, QH, and QL Towers General Description The series includes three and four leg angle towers, which are suited for a variety of antenna mounting positions and load conditions. The
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB #
SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationMASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
More informationCONSTRUCTION SPECIFICATION FOR POLE ERECTION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 615 SEPTEMBER 1993 CONSTRUCTION SPECIFICATION FOR POLE ERECTION 615.01 SCOPE 615.02 REFERENCES 615.05 MATERIALS TABLE OF CONTENTS 615.05.01 Concrete.02
More informationSIGN SUPPORT SPECIAL DETAILS
Michigan Department of Transportation Traffic and Safety SIGN SUPPORT SPECIAL DETAILS SIGN-205 THRU SIGN-899 Disclaimer: The information provided is a product of the Michigan Department of Transportation
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section AUTOMATIC CONTROL VALVE INSULATED ENCLOSURE (HOT BOX)
Section 15959 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and the installation of Automatic Control Valve Insulated Enclosures (Hot Boxes) for control valves installed on water lines
More informationTRAFFIC DIRECTION FOR RAIL LAP AS SHOWN (SEE NOTE 7) "SPLICE BOLT" WITH NUT MIDWEST GUARDRAIL SYSTEM (STANDARD AND REDUCED POST SPACING)
TRAFFIC DIRECTION FOR RAIL LAP AS SHOWN GR-MGS1, 1A (SEE NOTE 7) NOTES: 1. 2. 3. 4. 5. 6. 236 6'-3" 6'-3" 3'-1 " 3'-1 " 3'-1 " 3'-1 " GR-MGS1 (6'-3" POST SPACING) SPLICE DETAIL W-BEAM RAIL SPLICE MID-SPAN
More informationCONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 541 DECEMBER 1990 CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE 541.01 SCOPE 541.02 REFERENCES 541.03 DEFINITIONS 541.05 MATERIALS TABLE OF CONTENTS
More informationCONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - ECCENTRIC LOADER TERMINAL SYSTEM
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 555 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - ECCENTRIC LOADER TERMINAL SYSTEM TABLE OF CONTENTS 555.01 SCOPE 555.02
More informationKANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION
KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION Sheet 1 of 7 NOTE: This special provision is generally written in the imperative mood. The subject, the
More information1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.
SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2
More informationSECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]
More informationITEM 442 METALS FOR STRUCTURES
AFTER NOVEMBER 1, 2008 ITEM 442 METALS FOR STRUCTURES 442.1 Description. These specifications shall govern for materials such as structural steel, wrought iron, bronze, and other metals used in structures,
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel
More informationFitTech UP171F ELLIPTICAL (FOOTING) UP171I ELLIPTICAL (IN GROUND) UP171S ELLIPTICAL (SURFACE) Parts List
ELLIPTICAL BASE COVER DESCRIPTION FOOTBUCK WELD ASS'Y HARDWARE COMPLETE HARDWARE COMPLETE HARDWARE COMPLETE /" ANCHOR ROD 3/" x " HEX HEAD CAP SCREW 3/" WEDGE ANCHOR 3/" ANCHOR BOLT 3/" FLATWASHER (" O.D.)
More informationSECTION 716 SIGN MATERIALS SCOPE
716 716.01.01 MATERIALS COVERED SECTION 716 SIGN MATERIALS SCOPE A. This specification covers the kind and quality of materials used in the construction and fabrication of traffic control devices used
More informationSECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System
SECTION 05 5200 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install stainless steel railings and components. 1.02 REFERENCE
More informationSpecial Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:
CHAIN LINK FENCE - Item No. GATES - Item No. Special Provision No. 541S01 October 1998 AMENDMENT TO OPSS 541, DECEMBER 1990 OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced
More informationSECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Handrails and guardrails B. Guardrails for hatches and openings. C. Safety barriers. D. Roof edge protection. 1.2 RELATED SECTIONS
More informationCONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 552 NOVEMBER 2002 CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL TABLE OF CONTENTS 552.01 SCOPE 552.02 REFERENCES 552.03
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationCITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS
CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes furnishing and installing chain-link fabric fence, gate, and appurtenances. 1.02
More informationCONSTRUCTION SPECIFICATION FOR INERTIAL BARRIER MODULES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 550 JUNE 1995 CONSTRUCTION SPECIFICATION FOR INERTIAL BARRIER MODULES 550.01 SCOPE 550.02 REFERENCES 550.03 DEFINITIONS 550.04 Not Used 550.05 MATERIALS
More informationSmarter. Safer. Leaner.
Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter
More informationHIGH MAST CAMERA POLE ASSEMBLY GENERAL
10-3.24 HIGH MAST CAMERA POLE ASSEMBLY GENERAL The Contractor must furnish and install the following equipment for high mast camera pole assembly as described herein and as shown on the plans: 1. Camera
More informationItem 442 Metal for Structures
Item 442 Metal for Structures 1. DESCRIPTION 2. MATERIALS Provide structural steel, high-strength bolts, forgings, steel castings, iron castings, wrought iron, steel pipe and tubing, aluminum castings
More informationNew Jersey Turnpike Authority
New Jersey Turnpike Authority DOCUMENT UPDATE REQUEST Forward to Assistant Chief Engineer, Design Initiator Russell Saputo, PE Submittal Date 6/21/16 Firm Stantec Consulting Services Inc. Telephone 201-587-9040
More informationSECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System
SECTION 05720 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install supported glass stainless steel railings, glass
More informationPIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.
PIPE CULVERTS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe Culverts B. Pipe Aprons and Beveled Ends C. Footings for Concrete Pipe Aprons D. Pipe Apron Guards 1.02 DESCRIPTION OF WORK Construct pipe culverts,
More informationSECTION ORNAMENTAL ALUMINUM FENCING
SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMASONRY ANCHORS AND CONNECTORS May 6, 2014
Page - 1 This section includes specification text to assist in describing a variety of masonry anchors, connectors, and accessories intended for masonry construction. This document contains prepared master
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationOVERSHOT GATE TECHNICAL DATA SHEET
FRESNO OVERSHOT GATE TECHNICAL DATA SHEET Applications Fresno Overshot Gates effectively control upstream and downstream levels of canals. Improved flow control is achieved through the use of this fully
More informationDIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.
PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,
More informationSeismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE
SRSCR-0 Seismic Restraints Cent-R-Rail Supplement* Multi-Directional Bracing For Data-Track, Half-Rack and Multi-Tier Half-Rack Systems Structural Engineer S 9 *To be used in conjunction with Cooper B-Line
More informationCode Compliance Research Report CCRR-0118
Code Compliance Research Report CCRR-0118 Issue Date: 12-15-2009 Revision Date: 04-30-2018 Renewal Date: 04-15-2019 DIVISION: 06 00 00 WOOD, PLASTIC, AND COMPOSITES Section: 06 63 00 - Plastic Railings
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT
SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER OPR:CT 1 of 5 APPR:JAR:DBP:09-07-11 FHWA:APPR:09-07-11 a. Description. This work consists of furnishing and installing
More informationModel # 338SM-OP. 9/30/2011 Page 1 of 12
Model # 338SM-OP 9/30/2011 Page 1 of 12 9/30/2011 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 616 APRIL 2018 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03 DEFINITIONS
More informationDIVISION 1100 TRAFFIC
SECTION 1102 STREET LIGHTING GENERAL INFORMATION The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the
More informationESTIMATE OF QUANTITIES
ESTIMATE QUANTITIES STATE S.D. SHEET NO. TOTAL SHEETS 2 12 SPECIFICATIONS TEMPORARY PAVEMENT MARKING, Continued STATE S.D. SHEET NO. TOTAL SHEETS 3 12 South Dakota Standard Specifications for Roads and
More informationSECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 48 (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for
More informationCode Compliance Research Report CCRR-0238
Code Compliance Research Report CCRR-0238 Issue Date: 11-09-2016 Revision Date: 11-29-2018 Renewal Date: 11-09-2019 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC
More informationSECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationMETAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)
Page 1 of 6 SECTION 05515 METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION) PART 1 - GENERAL 1.1 SECTION INCLUDES A. Specialty custom designed, spring assisted, self-closing LADDER SAFETY GATE (LSG) for
More informationCONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.MUNI 721 NOVEMBER 2014 CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL TABLE OF CONTENTS 721.01 SCOPE 721.02 REFERENCES 721.03
More informationCONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 541 NOVEMBER 2005 CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE TABLE OF CONTENTS 541.01 SCOPE 541.02 REFERENCES 541.03 DEFINITIONS 541.04 SUBMISSION
More informationModel # 800SM-PS3. 8/3/2016 Page 1 of 8
Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationSECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL
SECTION 410 FENCES 410.1 GENERAL This work shall consist of the construction of fences and gates in substantial compliance with the specifications, lines, and grades shown on the plans or established by
More informationStudent Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel
More informationPIP STF05520 Details for Pipe Railing for Walking and Working Surfaces
TECHNICAL CORRECTION January 2017 Structural PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process
More information1. Hangers and supports for electrical equipment and systems.
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 PERFORMANCE REQUIREMENTS... 1 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS...
More informationSECTION CHAIN LINK FENCES AND GATES (PARK)
SECTION 02821 CHAIN LINK FENCES AND GATES (PARK) PART I GENERAL 1.1 SECTION INCLUDES A. Installation of chain link fences, and gate units provided by single source including erection accessories, fittings,
More informationModel # BT238-U6. 9/30/2014 Page 1 of 12
Model # BT238-U6 9/30/2014 Page 1 of 12 /30/2014 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationProduct Evaluation Report
Product Evaluation Report PER-09040 Page 1 of 5 This Document Published By: Initial Listing Re-Approved 5/12/2010 Progressive Engineering Inc. 58640 State Road 15 Goshen, Indiana 46528 574-533-0337 www.p-e-i.com
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)
ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL) 686.1. Description. This Item shall govern for designing, fabricating, furnishing and erecting steel traffic signal pole assemblies of the various types
More informationUNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS
, NEVADA YEAR 2015 REVISIONS SECTION TITLE AND REVISIONS SUMMARY EFFECTIVE DATE 217.S2 "Residential Curb and Gutter, R-Type" - New drawing to accommodate ADA requirements. 223 "Residential Driveway" -
More informationSECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
Page 1 of 6 SECTION 08 32 20 EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationSECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System
SECTION 05720 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install supported glass stainless steel railings, glass
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 616 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03
More informationLesson 7 REINFORCING CAGE. Version 1-1/
Lesson 7 REINFORCING CAGE 7-1 Version 1-1/15 7-1 Learning Outcomes Describe cage construction Determine the circumference of a shaft and rebar cage and calculate the required number of side spacers. Explain
More informationSECTION Summit Phenolic Lockers (Solid Phenolic Lockers)
SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with
More informationPreassembled steel stairs with concrete-filled treads.
SECTION 055113 - PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationDOORS/HATCHES DOORS/HATCHES LET US KNOW YOUR REQUIREMENTS WATERTIGHT DOORS HATCHES SCUTTLES PORT LIGHTS PHONE FAX
DOORS/HATCHES WATERTIGHT DOORS HATCHES SCUTTLES PORT LIGHTS LET US KNOW YOUR REQUIREMENTS 7 #00 -DOG FUMELIGHT DOOR #0 4-DOG WEATHERTIGHT DOOR #0 6-DOG WATERTIGHT DOOR #0 6-DOG SQUARE CORNER DOOR #04 6-DOG
More informationAPPENDIX A MEASUREMENT AND PAYMENT
P-150 DEMOLITION 4.01 Removal of pavement shall be measured per square yard based on the area shown on the plans. Any pavement removed outside the designed limits of removal because the pavement was damaged
More informationCONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 772 NOVEMBER 2017 (Formerly OPSS 772, November 2012) Note: The PROV published in November 2017 replaces OPSS 772 COMMON, November 2012 with no technical
More information1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.
BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2
More informationMidwest Roadside Safety Facility
Bridge Pit 1504 1/2" 38214 244" 6198 1" 25 16 15 14 13 12 11 10 9 8 7 25 6 5 51 3/16" 1300 4 3 2 1 Impact 2270P 2455 5/16" 62365 1379 1/2" 35039 - Barrier nos. 5-13 Anchored Ground Line Note: (1) Test
More informationCode Compliance Research Report CCRR-0238
Code Compliance Research Report CCRR-0238 Issued: 11-09-2016 Renewal Due: 11-09-2018 Revised: 11-10-2017 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC 894 Prairie
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 10/30/2015 Page 1 of
More informationSECTION METAL STAIRS
SECTION 05 51 00- METAL STAIRS PART 1 GENERAL 1.1 SCOPE OF WORK Fabricate and install metal stair assemblies in accordance with the requirements set forth in this section. Note: This specification applies
More informationSign & Post Installation. Standard Specifications and Standard Drawings. July 2017 Edition
Standard Specifications Sign & Post Installation Utility Services Department 500 George Street North, Peterborough, Ontario, K9H 3R9 Transportation Division Telephone: 705-742-7771 Fax: 705-876-4621 Sign
More informationCW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS
January 2014 SPECIFICATION CW 3550 R3 CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS 1. GENERAL CONDITIONS... 1 3. DESCRIPTION... 1 5. MATERIALS... 1 5.1 Drift Control Fence... 1 5.1.1 Approved
More informationSPECIAL SPECIFICATION 5989 Settlement Gauge
2004 Specifications CSJ 0047-14-067 SPECIAL SPECIFICATION 5989 Settlement Gauge Description. Install, maintain, and subsequently abandon settlement gauges as indicated for the purpose of obtaining foundation
More informationCode Compliance Research Report CCRR-0187
Code Compliance Research Report CCRR-0187 Issue Date: 11-29-2012 Revision Date: 07-24-2018 Renewal Date: 02-28-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT
More informationPATHWAYS FOR COMMUNICATIONS SYSTEMS
270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This
More informationSECTION ALTERNATING TREAD STEEL STAIRS
SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this
More informationSECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.
SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS
More informationA. American Society for Testing and Materials (ASTM):
SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 03420 - Precast, Prestress Concrete Sections. 3. 04420 - Concrete Unit Masonry. 4.
More informationSPECIFICATIONS PORTER No PORTABLE BASKETBALL BACKSTOP SYSTEM (FOR INDOOR OR OUTDOOR USE) WITH FAN FIBERGLASS BACKBOARD
SPECIFICATIONS PORTER No. 00535-940 PORTABLE BASKETBALL BACKSTOP SYSTEM (FOR INDOOR OR OUTDOOR USE) WITH FAN FIBERGLASS BACKBOARD Unit is designed for use in elementary schools, training camps, YMCA, park
More informationSTREET LIGHTING GENERAL INFORMATION
SECTION 1102 STREET LIGHTING GENERAL INFORMATION These specifications are for street lighting that is to be dedicated to the public and maintained by the City of Meridian. Such installations require a
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationSECTION METAL EQUIPMENT LOCKERS
SECTION 10 51 13 - METAL EQUIPMENT LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationSECTION 2831 ITEM F-162 CHAIN-LINK FENCES
SECTION 2831 ITEM F-162 CHAIN-LINK FENCES PART 1 - GENERAL 1.1 DESCRIPTION. This item shall consist of furnishing and erecting a chain-link fence in accordance with these specifications and the details
More informationCONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 772 NOVEMBER 2010 CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE TABLE OF CONTENTS 772.01 SCOPE 772.02 REFERENCES 772.03 DEFINITIONS 772.04 DESIGN
More informationKeuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.
SECTION 05 73 16 {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes. PART 1 GENERAL 1.1 SUMMARY A. Section includes cable railing system, with architectural metal
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S
SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...
More informationMAINE TURNPIKE AUTHORITY ADDENDUM NO. 2 CONTRACT EXIT 44 SOUTHBOUND ON RAMP IMPROVEMENTS MILE 44.3
MAINE TURNPIKE AUTHORITY ADDENDUM NO. 2 CONTRACT 2018.03 EXIT 44 SOUTHBOUND ON RAMP IMPROVEMENTS MILE 44.3 The following changes are made to the Proposal, Specifications, and Plans. PROPOSAL Proposal Sheets
More informationThis drawing. is preliminary. and not for. construction or. implementation. purposes. project number 170 END VIEW DESIGN STRENGTHS: PLAN
project number 70 Reference Line 2-0" Reference 3 -" 6-0" 6-0" 3 -" Line Box Culvert Roadway Finished Channel -0" -0" E VIEW 20-0" Riprap 0-0" Riprap Outlet Invert El 87.0 Sta 233+00.00 Inlet Invert El
More information