1 SECTION PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide Resilient Wall Base and Accessories, including resilient wall base, resilient stair accessories, resilient flooring accessories, resilient carpet accessories, as shown and detailed on the Drawings and specified herein. B. Related Sections include the following: 1.02 SUBMITTALS 1. Division 9, Section RESILIENT TILE FLOORING 2. Division 9, Section SHEET FLOOR COVERING A. Product Data: For each type of product specified. B. Samples for Verification: In manufacturer's standard sizes, but not less than 12 long, of each product color and pattern specified. C. Product Certificates: Signed by manufacturers of resilient wall base and accessories certifying that each product furnished complies with requirements QUALITY ASSURANCE A. Installer Qualifications: Engage an experienced installer to perform work of this Section who has specialized in installing resilient products similar to those required for this Project and with a record of successful in-service performance. B. Source Limitations: Obtain each type and color of product specified from one source and one (1) dye lot per room with resources to provide products of consistent quality in appearance and physical properties without delaying the Work. C. Fire-Test-Response Characteristics: Provide products with the following fire-test-response characteristics as determined by testing identical products per test method indicated below by a testing and inspecting agency acceptable to authorities having jurisdiction. 1. Critical Radiant Flux: 0.45 W/sq. cm or greater when tested per ASTM E Smoke Density: Maximum specific optical density of 450 or less when tested per ASTM E DELIVERY, STORAGE, AND HANDLING A. Deliver products to Project site in manufacturer's original, unopened cartons and containers, each bearing names of product and manufacturer, Project location, including dye lot number and shipping and handling instructions

2 B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50º and 90ºF. C. Move products into spaces where they will be installed at least 48 hours before installation, unless longer conditioning period is recommended in writing by manufacturer PROJECT CONDITIONS A. Maintain a temperature of not less than 70ºF or more than 95ºF in spaces to receive resilient products for at least 48 hours before installation, during installation, and for at least 48 hours after installation, unless manufacturer's written recommendations specify longer time periods. After post-installation period, maintain a temperature of not less than 55ºF or more than 95ºF for a minimum of 48 hours. B. Do not install products until they are at the same temperature as the space where they are to be installed. C. For resilient products installed on traffic surfaces, close spaces to traffic during installation and for time period after installation recommended in writing by manufacturer. D. Coordinate resilient product installation with other construction to minimize possibility of damage and soiling during remainder of construction period. Install resilient products after other finishing operations, including painting, have been completed EXTRA MATERIALS A. Furnish extra materials installed, as described below packaged with protective covering for storage, and identified with labels describing contents. PART II - PRODUCTS 2.01 MANUFACTURERS 1. Furnish not less than 10 linear feet for each 500 linear feet or fraction thereof, of each different type, color, pattern, and size of resilient product installed. 2. Deliver extra materials to University. A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, those indicated in the Resilient Flooring Accessory Schedule at the end of Part 3. B. Products: Subject to compliance with requirements, provide one of the products indicated for each designation in the Resilient Flooring Accessory Schedule at the end of Part RESILIENT WALL BASE A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Flooring Accessory Schedule. B. Vinyl Wall Base: Products complying with FS SS-W-40, Type II and with requirements specified in the Resilient Flooring Accessory Schedule

3 2.03 RESILIENT PRODUCTS A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Tile Flooring Schedule. B. Vinyl Wall Base: Products complying with FS SS-W-40, Type II and with requirements specified in the Resilient Tile Flooring Schedule. C. Rubber Stair Treads: Products of style suitable for use indicated and complying with FS RR-T-650, Composition A and with requirements specified in the Resilient Tile Flooring Schedule. D. Vinyl Stair Treads: Products of style suitable for use indicated and complying with FS RR-T-650, Composition B and with requirements specified in the Resilient Tile Flooring Schedule. E. Risers: Products of same manufacturer as stair treads and complying with requirements specified in the Resilient Tile Flooring Schedule. F. Stringers: Products of same manufacturer as stair treads and complying with requirements specified in the Resilient Tile Flooring Schedule. G. Rubber Accessory Moldings: Products complying with requirements specified in the Resilient Tile Flooring Schedule. H. Vinyl Accessory Moldings: Products complying with requirements specified in the Resilient Tile Flooring Schedule INSTALLATION ACCESSORIES A. Trowelable Leveling and Patching Compounds: Latex-modified, portland-cement-based formulation provided or approved by resilient product manufacturer for applications indicated. B. Stair-Tread-Nose Filler: Two-part epoxy compound recommended by resilient tread manufacturer to fill nosing substrates that do not conform to tread contours. C. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. PART III - EXECUTION 3.01 EXAMINATION A. Examine substrates, areas, and conditions where installation of resilient products will occur, with Installer present, for compliance with manufacturer's requirements. Verify that substrates and conditions are free of defects and fully comply with manufacturer's specified requirements for resilient product installation. Determine adhesion and dryness by performing flooring manufacturer's recommended bond and Calcium Chloride Test for moisture. Concrete slabs moisture should not exceed 5 lbs. per 1,000 sq. ft. per 24 hours. Provide University's Representative with test results prior to installation for all concrete slabs

4 3.02 PREPARATION A. General: Comply with manufacturer's written installation instructions for preparing substrates indicated to receive resilient products. B. Use trowelable leveling and patching compounds, according to manufacturer's written instructions, to fill cracks, holes, and depressions in substrates. C. Use stair-tread-nose filler, according to resilient tread manufacturer's written instructions, to fill nosing substrates that do not conform to tread contours. D. Remove coatings, including curing compounds, and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone, using mechanical methods recommended by manufacturer. Do not use solvents. E. Broom and vacuum clean substrates to be covered immediately before installing resilient products. After cleaning, examine substrates for moisture, alkaline salts, carbonation, or dust. Do not proceed with installation until unsatisfactory conditions have been corrected INSTALLATION A. General: Install resilient products according to manufacturer's written installation instructions. B. Apply resilient wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas where base is required. 1. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned. 2. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical substrates. 3. Do not stretch base during installation. 4. On masonry surfaces or other similar irregular substrates, fill voids along top edge of resilient wall base with manufacturer's recommended adhesive filler material. 5. Form outside corners on job, from straight pieces of maximum lengths possible, without whitening at bends. Shave back of base at points where bends occur and remove strips perpendicular to length of base that are only deep enough to produce a snug fit without removing more than half the wall base thickness. 6. Form inside corners on job, from straight pieces of maximum lengths possible, by cutting an inverted V-shaped notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate. C. Place resilient products so they are butted to adjacent materials and bond to substrates with adhesive. Install reducer strips at edges of flooring that would otherwise be exposed. D. Apply resilient products to stairs as indicated and according to manufacturer's written installation instructions

5 3.04 CLEANING AND PROTECTING A. Perform the following operations immediately after installing resilient products: 1. Remove adhesive and other surface blemishes using cleaner recommended by resilient product manufacturers. 2. Sweep or vacuum horizontal surfaces thoroughly. 3. Do not wash resilient products until after time period recommended by resilient product manufacturer. 4. Damp-mop or sponge resilient products to remove marks and soil. B. Protect resilient products against mars, marks, indentations, and other damage from construction operations and placement of equipment and fixtures during the remainder of construction period. Use protection methods indicated or recommended in writing by resilient product manufacturer. 1. Apply protective floor polish to vinyl resilient products installed on floors and stairs that are free from soil, visible adhesive, and surface blemishes, if recommended by manufacturer. a. Use commercially available product acceptable to resilient product manufacturer. b. Coordinate selection of floor polish with University's maintenance service. 2. Cover resilient products installed on floors and stairs with undyed, untreated building paper until inspection for Substantial Completion. C. Clean resilient products not more than 4 days before dates scheduled for inspections intended to establish date of Substantial Completion in each area of Project. Clean products according to manufacturer's written recommendations. 1. Before cleaning, strip protective floor polish that was applied to vinyl products on floors and stairs after completing installation only if required to restore polish finish and if recommended by resilient product manufacturer. 2. After cleaning, reapply polish on vinyl products on floors and stairs to restore protective floor finish according to resilient product manufacturer's written recommendations. Coordinate with University's maintenance program RESILIENT FLOORING ACCESSORY SCHEDULE A. Rubber Wall Base RWB-[#]: Burke Cove Wall Base, as manufactured by Burke, or equal. 2. Color and Pattern: 3. Style: Topset. 4. Minimum Thickness: ⅛

6 5. Height: 4 in Administrative areas and 6 in Hospital or clinic patient care areas. 6. Lengths: 4 lengths. 7. Outside Corners: Formed on site. 8. Inside Corners: Formed on site. 9. Ends: Premolded. 10. Surface: Smooth. B. Rubber Stair Treads and Accessories RSTA-[#]: **Consultant to Edit** 2. Color and Pattern: 3. Rubber Stair Treads: 4. Abrasive Strips: 5. Nosing Style: 6. Nosing Height: 7. Thickness: 8. Size: 9. Rubber Stringers: C. Vinyl Stair Treads and Accessories VSTA-[#]: **Consultant to Edit** 2. Color and Pattern: 3. Vinyl Stair Treads: 4. Abrasive Strips: 5. Nosing Style: 6. Nosing Height: 7. Thickness: 8. Size: 9. Vinyl Risers:

7 D. Rubber Accessory Molding RAM-[#]: **Consultant to Edit** 2. Color: 3. Product Description: 4. Profile and Dimensions: E. Vinyl Accessory Molding VAM-[#]: **Consultant to Edit** 2. Color: 3. Product Description: 4. Profile and Dimensions: END OF SECTION

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C).

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C). SECTION 09651 - RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

D. Maintenance data for resilient floor tile to include in Operating and Maintenance Manual specified in Division 1.

D. Maintenance data for resilient floor tile to include in Operating and Maintenance Manual specified in Division 1. SECTION 09660 RESILIENT TILE FLOORING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified. SECTION 09 65 19 RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 SUMMARY A. Section includes vinyl composition floor tile and accessories indicated and as specified. 1.2 SUBMITTALS A. Product Data: Submit

More information

PART 1 GENERAL RESILIENT ACCESSORIES

PART 1 GENERAL RESILIENT ACCESSORIES SECTION 09 65 13.33 (09655) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Resilient Base 2. Transition Edges 3. Stair Nosings 1.2 REFERENCES A. ASTM International Publications: 1. C241 Standard Test

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 096519 - RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE MANNINGTON COLORFIELDS SHEET RUBBER FLOORING Section 09 65 16 Sheet rubber Flooring (Thermoset Rubber) Created May 2012 Mannington Mills, Inc. P. O. Box

More information

ARCHITECTURAL GUIDE SPECIFICATIONS

ARCHITECTURAL GUIDE SPECIFICATIONS ARCHITECTURAL GUIDE SPECIFICATIONS MANNINGTON COLORSCAPE, COLORSPEC, & ONE-STEP STAIR TREADS Section 09 65 13.23 Resilient Stair Treads [Thermoset Rubber Type TS] Created November, 2008 Mannington Mills,

More information

RESILIENT PHOTOLUMINESCENT STAIR TREADS

RESILIENT PHOTOLUMINESCENT STAIR TREADS THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 09 65 16 - RESILIENT SHEET FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PART 1 GENERAL RESILIENT SHEET FLOORING

PART 1 GENERAL RESILIENT SHEET FLOORING SECTION 09 65 16 (09652) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Resilient Sheet Flooring a. All seams heat-welded. 1.2 REFERENCES A. Americans with Disabilities Act (ADA) II Public Accommodations

More information

SECTION (09620) - RESILIENT ATHLETIC FLOORING

SECTION (09620) - RESILIENT ATHLETIC FLOORING PART 1 GENERAL 1.01 SUMMARY SECTION 09 65 66 (09620) - RESILIENT ATHLETIC FLOORING A. Section Includes: 1. Resilient Athletic Flooring a. Adhesive and Accessories B. Related Sections: 1.02 REFERENCES 1.

More information

RESILIENT ECO NATURALS, DEFIANT, AND PHOTOLUMINESCENT STAIR TREADS

RESILIENT ECO NATURALS, DEFIANT, AND PHOTOLUMINESCENT STAIR TREADS THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

SECTION RESILIENT FLOORING

SECTION RESILIENT FLOORING PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 09 65 00 RESILIENT FLOORING A. Resilient sheet and tile flooring B. Resilient base C. Resilient stair nosing, treads, risers and skirting 1.2 REFERENCES A. ASTM

More information

SECTION RESINOUS FLOORING

SECTION RESINOUS FLOORING SECTION 09705 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section includes all materials and installation necessary to provide resinous flooring system with integral cove base and top finish

More information

RESILIENT ACCESSORIES

RESILIENT ACCESSORIES INCLUDING COVE CAP, CHAIR RAIL, CORNER GUARD, TUB MOULDING, COVE FILLER STRIP AND SUBFLOOR LEVELER SYSTEM THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED

More information

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. TARKETT WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF

More information

RESILIENT RUBBER STAIR TREADS WITH RISER

RESILIENT RUBBER STAIR TREADS WITH RISER THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

CONDUCTIVE RESILIENT FLOORING

CONDUCTIVE RESILIENT FLOORING THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 096813 - TILE CARPETING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Section STATIC DISSIPATIVE RESILIENT FLOORING

Section STATIC DISSIPATIVE RESILIENT FLOORING THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. TARKETT WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF

More information

Section JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY INFORMATION OR SPECIFICATIONS FOUND IN THIS DOCUMENT.

Section JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY INFORMATION OR SPECIFICATIONS FOUND IN THIS DOCUMENT. TRADITIONAL RUBBER AND VINYL WALL BASE, TRADITIONAL PHOTOLUMINESCENT RUBBER WALL BASE, PERCEPTIONS WALL BASE, TIGHTLOCK CARPET AND, BASEWORKS THERMOSET WALL BASE, TRADITIONAL WALL BASE AND VENT COVE WALL

More information

RESILIENT FLOORING

RESILIENT FLOORING RESILIENT FLOORING 09650-1 SECTION 09650 RESILIENT FLOORING Part 1 General RELATED DOCUMENTS: Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1

More information

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. TARKETT WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF

More information

CONDUCTIVE RESILIENT FLOORING

CONDUCTIVE RESILIENT FLOORING THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include: CONNOR PowerDrop Page 1 SECTION 09624 RESILIENT ATHLETIC SURFACING PART 1 - GENERAL 1.01 SUMMARY A. Section includes: Resilient athletic surfacing, including [recycled] [virgin] rubber flooring B. Related

More information

End of Addendum No. 3

End of Addendum No. 3 ADDENDUM NO. 3 DATE: May 5, 2017 PROJECT: OWNER: BID DATE: Jail Renovations Monday, May 8, 2017 at 2:00 pm The following shall be incorporated into the Contract Documents dated 19 APR 2017. PROJECT MANUAL

More information

Section RESILIENT SAFE-T VINYL SHEET FLOORING

Section RESILIENT SAFE-T VINYL SHEET FLOORING RESILIENT SAFE-T VINYL SHEET FLOORING THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. TARKETT WILL NOT BE

More information

SECTION (09650) - RESILIENT FLOORING

SECTION (09650) - RESILIENT FLOORING SECTION 09 65 00 (09650) - RESILIENT FLOORING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. PVC Thresholds 2. Solid Vinyl Transition Edges 3. Stair Nosings B. Related Sections: 1.02 REFERENCES 1.

More information

SPECIFICATIONS - CARPET TILE 09681

SPECIFICATIONS - CARPET TILE 09681 SPECIFICATIONS - CARPET TILE 09681 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION TILE CARPETING

SECTION TILE CARPETING SECTION 096813 TILE CARPETING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

LINOLEUM SHEET FLOORING

LINOLEUM SHEET FLOORING THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT

More information

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs. SECTION PART 1 - GENERAL 1.1 SUMMARY A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs. 1.2 RELATED DOCUMENTS A. Related Sections include the

More information

STUDIO 2LR ARCHITECTURE + INTERIORS

STUDIO 2LR ARCHITECTURE + INTERIORS STUDIO 2LR ARCHITECTURE + INTERIORS 6University of South Carolina, School of Medicine USC SOM #28 Sim II 6311 Garners Ferry Road, Columbia, South Carolina State Project Number: H27-Z325 September 27, 2018

More information

Section RESILIENT TILE FLOORING INCLUDING SOLID VINYL FLOOR TILE

Section RESILIENT TILE FLOORING INCLUDING SOLID VINYL FLOOR TILE THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. TARKETT WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 65 16 A. This Section includes resilient sheet flooring. 1. Use this section only for NCA projects. 2. Delete between // ---- // if not applicable to project.

More information

SECTION BROADLOOM CARPET

SECTION BROADLOOM CARPET SECTION 09680 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Carpet as shown and detailed on the Drawings and specified

More information

B. Samples: For each exposed product and for each color and pattern specified.

B. Samples: For each exposed product and for each color and pattern specified. SECTION 096519 - RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Vinyl composition floor tile. 2. Vinyl composition floor tile (VCT) shall be installed in each Unit at / in

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 09 6816 - SHEET CARPETING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624 3 PART SPECIFICATION #Z 624 THE FOLLOWING DOCUMENT IS A GUIDE FOR CREATING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. ZANDUR ACCEPTS NO LIABILITY FOR ANY DAMAGES RESULTING FROM THE USE

More information

SECTION RESILIENT TILE FLOORING

SECTION RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 65 19 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION RESILIENT TILE FLOORING PART 1 GENERAL

SECTION RESILIENT TILE FLOORING PART 1 GENERAL SECTION 09650 RESILIENT TILE FLOORING PART 1 GENERAL 1.0 SCOPE A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions and Division 00 & 01 specification

More information

SECTION TERRAZZO FLOOR TILE

SECTION TERRAZZO FLOOR TILE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 66 16 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // ----- // if not applicable to project. Also delete any other item or

More information

1. Division 09 Section "Rough Carpentry."

1. Division 09 Section Rough Carpentry. GREENSPOINT AND LAUDER RD. EC/PRE-KlK PAGE 1 SECTION 096400 - WOOD FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION RESILIENT BASE AND ACCESSORIES

SECTION RESILIENT BASE AND ACCESSORIES SECTION 09 65 13 RESILIENT BASE AND ACCESSORIES SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes:

More information

*************************************************************************************

************************************************************************************* 09651 RESILIENT SHEET FLOORING ************************************************************************************* CSI 2004 MasterFormat number: 09 65 16. SPECIFIER: Do not use resilient sheet flooring

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09665 RESILIENT SHEET FLOORING PART 1 - GENERAL 1.1 DESCRIPTION A. This Section specifies the installation of sheet flooring with backing and integral cove base. 1.2 RELATED WORK A. Color and pattern:

More information

GUIDE SPECIFICATION

GUIDE SPECIFICATION GUIDE SPECIFICATION 09 64 33.01 Kährs Canvas Collection 940 Centre Circle, Suite 1000 Altamonte Springs, FL 32714 Tim Colgan Telephone: 407-492-2441 Fax: 407-260-9933 Tim.colgan@kahrs.com Web Site: http://www.kahrs.com

More information

GUIDE SPECIFICATION

GUIDE SPECIFICATION GUIDE SPECIFICATION 09 64 33.01 940 Centre Circle, Suite 1000 Altamonte Springs, FL 32714 Telephone: 407-260-9910 Fax: 407-260-9933 Toll Free: 800-800-5247 Web Site: http://www.kahrs.com This Guide Specification

More information

Bid No. B14-09 Building 900 Cafeteria, Multi-Purpose Room Renovation Flooring

Bid No. B14-09 Building 900 Cafeteria, Multi-Purpose Room Renovation Flooring Bid No. B14-09 Cafeteria, Multi-Purpose Room Renovation Flooring Addendum No. 1 This Addendum No. 1 sets forth modifications to portions of the bid and contract documents for the above-referenced work

More information

SECTION RESILIENT BASE AND ACCESSORIES

SECTION RESILIENT BASE AND ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 65 13 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP#

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP# SECTION 096466 - WOOD ATHLETIC FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in. 1.2 SUMMARY

More information

RESILIENT TILE FLOORING

RESILIENT TILE FLOORING SECTION 09660 RESILIENT TILE FLOORING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09665 - Sheet Vinyl Floor System. 3. 08710 - Finish Hardware. 4. 15421 - Drains

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

RESILIENT FLOORING: Hot and Heavy - Secoya

RESILIENT FLOORING: Hot and Heavy - Secoya 160 South Industrial Blvd. Calhoun, GA 30701 Section 096519 RESILIENT FLOORING: Hot and Heavy - Secoya This document is intended as a suggested guide for editing your architectural guide specification.

More information

RESILIENT FLOORING: Select Step Wood

RESILIENT FLOORING: Select Step Wood 160 S. Industrial Blvd Calhoun, GA 30701 Section 096519 RESILIENT FLOORING: Select Step Wood This document is intended as a suggested guide for editing your architectural guide specification. Mohawk Group

More information

Overall Thickness Wear Layer Thickness. Factory in. (2.0 mm) in. (2.0 mm) Diamond 10 Technology coatingcultured

Overall Thickness Wear Layer Thickness. Factory in. (2.0 mm) in. (2.0 mm) Diamond 10 Technology coatingcultured PRODUCT SPEC PAGE ColorArt Medintech l Medintone Homogeneous Sheet Flooring Product Information Construction Product Line International Product Specifications Overall Thickness Wear Layer Thickness Factory

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 096623 - RESINOUS MATRIX TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format UPOFLOOR Americas, Inc. 940 Centre Circle, Suite 1000 Altamonte Springs FL, 32714 Tel. 1-800-800-5247

More information

Powerdek Fleck. SECTION Resilient Athletic Flooring

Powerdek Fleck. SECTION Resilient Athletic Flooring SECTION 09622 Resilient Athletic Flooring PART 1: GENERAL 1.0 SUMMARY 1.0.1 Work Included A. Prefabricated Rubber Sports Flooring B. Adhesive and accessories required for installation and maintenance 1.0.2

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 09 6613 - PORTLAND CEMENT TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION R CARPET PART 1 - GENERAL 1.1 SUMMARY

SECTION R CARPET PART 1 - GENERAL 1.1 SUMMARY SECTION 09 68 13R CARPET PART 1 - GENERAL 1.1 SUMMARY A. This section covers the specification standards for modular and broadloom carpet. It includes construction, submittals, installation and warranty

More information

Control XT SECTION Resilient Athletic Flooring

Control XT SECTION Resilient Athletic Flooring Control XT SECTION 09 65 22 Resilient Athletic Flooring PART 1: GENERAL 1.0 SUMMARY 1.0.1 Work Included A. Rubber sports flooring B. Adhesive and accessories required for installation and maintenance.

More information

INSTALLATION INFORMATION

INSTALLATION INFORMATION INSTALLATION INFORMATION INTRODUCTION We have prepared the following recommendations and instructions that apply to most applications. Only factory-approved adhesives are to be used for the warranty to

More information

A. General: Submit each item in this Article according to the Conditions of the Contract and Division 1 Specifications Sections

A. General: Submit each item in this Article according to the Conditions of the Contract and Division 1 Specifications Sections SECTION 09 65 16.13 LINOLEUM FLOOR COVERINGS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Section Performance Floor Asemblies (Also Dance Floor Assemblies)

Section Performance Floor Asemblies (Also Dance Floor Assemblies) Sample Specifications for kiwifloor Studio System Section 09646 Performance Floor Asemblies (Also Dance Floor Assemblies) PART 1 GENERAL 1.1 GENERAL A. Work of this Section, as shown or specified, shall

More information

TILE TILE

TILE TILE 09300 - TILE 09300-1 PART ONE: GENERAL 1.1 Description TILE 1.1.1 Work of this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance with the requirements

More information

SECTION TILING

SECTION TILING PART 1 GENERAL 1.01 SECTION INCLUDES A. Ceramic Tile for floor applications. B. Ceramic Tile for wall applications. C. Ceramic accessories. D. Ceramic trim. E. Non-ceramic trim. 1.02 RELATED REQUIREMENTS

More information

1.1 DESCRIPTION OF WORK A. Provide new resilient flooring and base where noted on drawings.

1.1 DESCRIPTION OF WORK A. Provide new resilient flooring and base where noted on drawings. PART 1 - GENERAL Bid #2017-08 1.1 DESCRIPTION OF WORK A. Provide new resilient flooring and base where noted on drawings. 1.2 SUBMITTALS A. Product Data: 1. Submit manufacturer s technical data and installation

More information

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax NORTH ELEVATION 1 1/8" = 1'-0" WEST ELEVATION 2 1/8" = 1'-0" SOUTH ELEVATION 3 1/8" = 1'-0" EXTERIOR ELEVATIONS A2.0 EAST ELEVATION 4 1/8" = 1'-0" EXTERIOR FRAME TYPES 1 1/4" = 1'-0" 2 INTERIOR FRAME TYPES

More information

KOSTER AMERICAN CORPORATION

KOSTER AMERICAN CORPORATION Section 09699 PART 1 GENERAL Water Vapor Emission Control Systems 1.1 RELATED DOCUMENTS A. Drawings, documents, and general provisions of the Contract, including, but not necessarily limited to, General

More information

Installation Instructions for Hercules Rib 52

Installation Instructions for Hercules Rib 52 Page 1 of 5 Installation Instructions These instructions supersede any verbal or written instructions from connexus representatives, and must be followed in order for the warranty to be in effect. Delivery

More information

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6 INSTALLATION GUIDE PAGE 1 of 6 MATERIALS REQUIRED FOR INSTALLATION: Tape Measurer Square Ruler Utility Knife 100lb Roller (if using adhesive) ACCEPTABLE SUBFLOORS: Happy Feet International will not warrant

More information

SECTION WOOD STRIP FLOORING

SECTION WOOD STRIP FLOORING SECTION 096429 WOOD STRIP FLOORING PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. Work of this Section, as shown or specified, shall be in accordance with the requirements of the Contract Documents. 1.2 SECTION

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 07 1616 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

L AIR International manufactures a variety of pre-fabricated, modular sprung flooring systems for various applications, including:

L AIR International manufactures a variety of pre-fabricated, modular sprung flooring systems for various applications, including: Manufacturer: L AIR International 117 Vacek St Fort Worth, Texas USA Tel: 817.237.9390 Toll Free 844.243.8574 www.lairfloors.com GUIDE SPECIFICATION SECTION 096452 - RESILIENT STUDIO & STAGE FLOORING (EXCELLE

More information

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6 INSTALLATION GUIDE PAGE 1 of 6 MATERIALS REQUIRED FOR INSTALLATION: Tape Measurer Square Ruler Chalk Line Utility Knife Hand/Seam Roller 100lb Roller ACCEPTABLE SUBFLOORS: Happy Feet International will

More information

1/16 Single Broadcast Polymer Flooring System

1/16 Single Broadcast Polymer Flooring System specification 1/16 Single Broadcast Polymer Flooring System Part 1 - GENERAL General Provisions A. Work to be covered by this section, under written specification or by drawing, shall comply with all provisions

More information

Note: Delete any section below not relevant to this project; add others as required.

Note: Delete any section below not relevant to this project; add others as required. Part 1 General 1.1 section includes A. WriteLite B. Related Sections Note: Delete any section below not relevant to this project; add others as required. 1. Section 06 20 00 Finish Carpentry 2. Section

More information

09652 RESILIENT TILE FLOORING

09652 RESILIENT TILE FLOORING 09652 RESILIENT TILE FLOORING SPECIFIER: Specific resilient tile products specified in this section are tile that have been tested by the MDCPS Materials Testing and Evaluation Laboratory to verify producer

More information

SECTION EPOXY TERRAZZO

SECTION EPOXY TERRAZZO SECTION 09 66 23.16 EPOXY TERRAZZO THIS GUIDE SPECIFICATION HAS BEEN PREPARED BY THE NATIONAL TERRAZZO AND MOSAIC ASSOCIATION, INC., AND IS DISTRIBUTED FOR USE BY ITS MEMBERS AND DESIGN PROFESSIONALS.

More information

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS SECTION 09699 MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS PART 1 GENERAL 1.1 SECTION INCLUDES A. Testing and application of systems for the reduction of moisture resistant or water-proof

More information

09651 RESILIENT SHEET FLOORING

09651 RESILIENT SHEET FLOORING 09651 RESILIENT SHEET FLOORING SPECIFIER: Do not use resilient sheet flooring in food service areas or where oils, grease or high heat can cause slipping or deteriorate the surface. No RSF has been found

More information

ARTIK ART & ARCHITECTURE STAGE FLOORING ASSEMBLY SECTION STAGE FLOORING ASSEMBLY

ARTIK ART & ARCHITECTURE STAGE FLOORING ASSEMBLY SECTION STAGE FLOORING ASSEMBLY SECTION 09 65 40 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to

More information

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT SECTION 09 6 13 RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. PART 1 - GENERAL 1.1 SUMMARY EDIT TO SUIT PROJECT A. Work of this Section consists

More information

A. This Section includes resinous flooring systems with epoxy body coat(s).

A. This Section includes resinous flooring systems with epoxy body coat(s). SECTION 096723 - RESINOUS FLOORING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes resinous flooring systems with epoxy body coat(s). 1. Application Method: Troweled (Slurry, Seeded or Broadcast

More information

Installation Guide LVP Glue Down

Installation Guide LVP Glue Down 734 SOUTH RIVER STREET CALHOUN, GEORGIA 1.844.225.3100 www.encorehospitalitycarpet.com Installation Guide LVP Glue Down Materials Required for Installation: Tape Measure Square ruler Chalk line Utility

More information

RESINOUS FLOORING

RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Bid #2017-17 A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 093000 - TILING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

B. Related Sections: 1. Division 07 Section Joint Sealants for sealing of expansion, contraction, control, and isolation joints in tile surfaces. SECTION 093000 - CERAMIC TILE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Bush Elem. Addition & Alterations QUARRY TILE SECTION QUARRY TILE PART 1 - GENERAL

Bush Elem. Addition & Alterations QUARRY TILE SECTION QUARRY TILE PART 1 - GENERAL 73651.01 QUARRY TILE 093016-1 1.1 RELATED DOCUMENTS: SECTION 093016 - QUARRY TILE PART 1 - GENERAL A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division

More information

SECTION SHEET VINYL FLOORING Cast-In-Place Concrete Hardwood Strip Flooring System.

SECTION SHEET VINYL FLOORING Cast-In-Place Concrete Hardwood Strip Flooring System. SECTION 09665 SHEET VINYL FLOORING PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 03300 - Cast-In-Place Concrete. 2. 09561 - Hardwood Strip Flooring System. 1.02 REFERENCES A. ASTM F710-92 Standard

More information

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

POLYACRYLATE MODIFIED THINSET TERRAZZO 1 PART 1 - GENERAL GUIDE SPECIFICATION POLYACRYLATE MODIFIED THINSET TERRAZZO - REVISED AUG 02 1.1 RELATED DOCUMENTS A. Section includes thin set Polyacrylate Modified Terrazzo flooring (and integral cove

More information

Section SECTION RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Section SECTION RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 096723 - RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION WOOD ATHLETIC FLOORING

SECTION WOOD ATHLETIC FLOORING SECTION 096466 WOOD ATHLETIC FLOORING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Wood sports-floor assemblies. B. Related Sections: 1. Section 011100 Summary of Work, for Contract 1-G Scope of

More information

Product Size Thickness Installation direction Seams treatment

Product Size Thickness Installation direction Seams treatment INSTALLATION INSTRUCTIONS FOR GERFLOR SAGA 2, CREATION TILES AND PLANKS This document refers to the following products: Product Size Thickness Installation direction Seams treatment Creation Tiles See

More information

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION SECTION 09 68 13 TILE CARPETING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular carpet tile. (CP1, CP2A, CP2B, CP2C) 2. Installation materials, including adhesives. 3. Supplementary components,

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES CSI Exceed March 1st, 2018-This document is provided solely as a convenience for spec writers in the drafting process. PLAE will not be held responsible for the use or alteration of any information contained

More information