1

2 Content Page OPTIC Liners 3 OPTIC 2 Consumables 5 OPTIC 3 Consumables 7 Spare Parts 9 OPTIC-4 Consumables 12 Spare Parts 13 OPTIC accessories 15 LINEX Consumables, spare parts 16 PHASER Consumables 17 Spare Parts 18 2

3 OPTIC Liners Explanation A Fritted Liner This liner contains a medium porosity frit made. This liner can be used for hot and cold Split/Less injections. In addition, if used with a suitable packing material the liner can be used for large volume injection, thermal desorption, solid sampling and pyrolysis applications. Pk/ 5 A Splitless Liner This liner is for hot and cold splitless injection of sample volumes below 1 µl. The narrow internal diameter of 1 mm ensures fast transfer of the sample to the column under splitless conditions. We advise this liner for SPME techniques. Pk/ 5 A Single-Necked Liner This liner is specially made for hot or cold split injections. The large internal diameter of 3.4 mm facilitates mixing of the sample with the carrier gas. Pk/ 5 A Packed Liner This liner contains a highly deactivated packing that combines a maximum operating temperature of 350 C with a high sample capacity (in excess of 100µl in most cases). This liner has been developed for the EPA 8270 method. A Baffled Splitless Liner This liner is for hot and cold splitless injection of sample volumes below 1 µl. The narrow internal diameter of 1 mm ensures fast transfer of the sample to the column under splitless conditions. With this liner the sample will not have any chance of being injected directly to the bottom of the injector. This liner will give better results for the high boiling components. Pk/ 5 A Sintered glass liner This liner is both very inert and capable of operation up to 350 C. As such it is suitable for the large volume injection of compounds that have the tendency to breakdown. The capacity of the liner is lower than that of a packed liner (about 50 µl, depending upon solvent used). To maximize its capacity, the liner should be used in combination with a syringe fitted with a dome tipped, side-hole needle. Pk/ 5 A100133S A A Special deactivated Sintered glass liner Fritted liner (frit 20 mm) filled with Tenax TA Fritted Liner filled with Tenax GR This liner is both very inert, highly deactivated and capable of operation up to 350 C. As such it is suitable for the large volume injection of compounds that have the tendency to breakdown. The capacity of the liner is lower than that of a packed liner (about 50 µl, depending upon solvent used). To maximize its capacity, the liner should be used in combination with a syringe fitted with a dome tipped, side-hole needle. Pk/ 5 The liner contains Tenax TA mesh packing material that combines a maximum operating temperature (350 C) with a high sample capacity (in excess of 100 µl in most cases). Pk/ 5 The liner contains Tenax GR mesh packing material that combines a maximum operating temperature (350 C) with a high sample capacity (in excess of 100 µl in most cases). Pk/ 5 A Fritted Liner (frit on 15 mm) packed with Tenax TA The liner contains Tenax TA mesh packing material that combines a maximum operating temperature (350 C) with a high sample capacity (in excess of 100 µl in most cases). Pk/ 5 A Starter Kit for LVI Sampling, pack of 5 different liners A starter kit for large volume injections. With 5 different liners. 1 x A100001, fritted liner 1 x A100049, single necked liner 1 x A100060, A-type packed liner 1 x A100132, Baffled splitless liner 1 x A100133, Sintered glass liner 3

4 OPTIC Liners Explanation A L L L L Fritted Liner packed with Chromosorb W Fritted liner with taper LINEX DMI tapered liner Needle Guide DMI Tapered liner LINEX metal Needle Guide The liner contains Chromosorb W packing material that combines a maximum operating temperature (350 C) with a high sample capacity (in excess of 100 µl in most cases). Pk/ 5 This liner contains a medium porosity frit made from sintered, deactivated glass. With a taper on the bottom. This liner can be used for split/less, thermal desorption, pyrolysis injections. In addition, if used with a suitable packing material the liner can be used for large volume injection, thermal desorption, solid sampling and pyrolysis applications. Pk/ 5 This liner has special dents to hold the DMI-vail. This ensures that there will be no compounds traps on the frit. The taper will increase sensitivity of the increased linear velocity to the column, which will reduce peak width and increase peak height Pk/ 5 The needle guide will ensure the automated introduction of sample in the DMI Vial when using a extra long needled syringe. Pk/ 5 The needle guide will ensure the automated introduction of sample in the DMI Vial when using a extra long needled syringe. Made out of metal DMI Sample Insert 30µl The container for sample when using the DMI technique, volume 30 µl DMI Sample Insert, 60 µl The container for sample when using the DMI technique, volume 60 µl. 00 4

5 OPTIC 2 Consumables A PTFE Covered Septum, 9 mm Pk/50 A Graphite Ferrule for mm ID Column, Pk/10 A Graphite Ferrule for 0.53 mm ID Column, Pk/10 A PTFE Reducing Ferrule, 1/8" to 1/16", Pk/10 A High Quality Low Bleed Septum 9 mm, Pl/25 A PTFE Top Boss Insulator, Pk/10 A Merlin Micro-seal 5

6 OPTIC 2 Consumables A Brass Liner Blanking Cap Pk/10 A Nylon Liner Blanking Cap Pk/10 A Stainless Steel Liner Blanking Cap Pk/10 A Graphite Ferrule for mm ID Column, pk/10 6

7 OPTIC 3 Consumables A PTFE Reducing Ferrule, 1/8" to 1/16", pk/10 A PTFE Top Boss Insulator, pk/ High resistance Silicon O-ring for liner pk/ 20 H General Purpose Red Septa 11 mm, pk/25 H Low Bleed White Septum 11 mm pk/25 H Graphite Ferrule for 0.53 mm ID Column, pk/10 H Graphite Ferrule for mm ID Column, pk/10 7

8 OPTIC 3 Consumables H Graphite/Vespel Ferrule (for OPTIC 3 Special Tee) pk/10 H O-ring for 1/4 Tube, 5.7 x 1.9 pk/ 25 H Empty tube for Thermal Desorption 1/4 pk/5 H µl syringe for Shimadzu AOC 20i pk/ 3 H OPTIC 3 HT Injection Port Septa transparent pk/ 25 H OPTIC Injector Metal Ferrule Column ID =<0.25mm pk/10 H OPTIC Injector Metal Ferrule Column ID 0.32mm pk/ 10 H has been replaced by OPTIC Injector Metal Ferrule Column ID 0.53mm pk/ 10 H has been replaced by OPTIC injector metal nut for metal ferrule, pk/ 5 8

9 OPTIC 3 Spare parts H has been replaced by Stainless Steel Injector Bottom Nut pk/ 5 H Standard Septum Nut pk/ 1 H Clamp Nut Insulator pk/ 1 H Has been replaced by Injector Bottom Insulation Cap pk/ 1 H GC Oven Thermocouple pk/ 1 H OPTIC 3 EGC Fitting 1/8" pk/ 1 9

10 OPTIC 3 Spare parts H Viton O-ring for EGC Fittings 00 H One-touch mini connector for OPTIC 3 cooling valve Pk/ 1 H OPTIC 3 Charcoal Split Filter Cartridge H Split Line Charcoal Filter Assembly (H H200051) H OPTIC Injector Metal Nut for metal ferrule Pk/ 5 L Fitting 1/16 OD tubing thread 10

11 OPTIC 3 Spare parts H Solvent Monitor Assembly H Septum Nut Sampling connection (1/16) H has been replaced by Key for OPTIC Injector Bottom Nut Pk/ 1 H has been replaced by OPTIC 3 Column Mounting Jig L has been replaced by Liner O-ring material: Viton Pk/ 50 11

12 OPTIC-4 Consumables OPTIC Low Bleed White Septum, 11 mm, pk/ OPTIC Graphite Ferrule for 0.53 mm ID Column, pk/ OPTIC Graphite Ferrule for mm ID Column, pk/ OPTIC Inlet Metal Ferrule, Column ID 0.25mm, pk/ OPTIC Inlet Metal Ferrule, Column ID 0.32mm, pk/ OPTIC Inlet Metal Ferrule, Column ID 0.53mm, pk/ OPTIC Viton O-ring 4.5 ID x 2.0, pk/ OPTIC EFC Inlet Connection o- ring, pk/ OPTIC DMI Sample Insert 30µl, pk/ OPTIC High Resistance Silicon o- ring P5, pk/20 12

13 OPTIC-4 Spare parts OPTIC Column Mounting Jig OPTIC Stainless Steel Inlet Bottom Nut, pk/ Key for OPTIC Inlet Bottom Nut OPTIC Inlet Bottom Nut for Metal Ferrule, pk/ OPTIC-4 Inlet Septum Nut Standard OPTIC-4 Inlet Clamp Nut Insulator OPTIC-4 Inlet Septum Nut, Shimadzu type OPTIC-4 Inlet Septum Nut Insert, Shimadzu type OPTIC-4 External Solvent Monitor Assembly 13

14 OPTIC-4 Spare parts OPTIC-4 Inlet Cooling Valve OPTIC-4 EFC Fitting, 1/8" tubing Shimadzu aluminum packing type -G, pk/ Fuse, Slow Blow, 230V, 6.3A, pk/ OPTIC Inlet Bottom Insulation Cap OPTIC GC Oven Thermocouple OPTIC-4 Split Line Filter Assy 14

15 OPTIC Accessories G Gas Leak Detector LD Packing Funnel for Liners Glass wool inserter Glass wool remover Septum Pick Injector port cleaning Kit Pk/ Ferrule removal tool Or OPTIC Standard On-Column Tool kit Or OPTIC On-Column Tool 15 kit for Shimadzu GC

16 LINEX Consumables High resistance Silicon O-ring for liner, pk/ 20 L CDCS Liner Caps Assy Pk/ Fitting 1/16" OD tubing, thread, pk/ LINEX Bushing LINEX Accessories L CDCS 98 position Tray for Capped Liners L LINEX 98 position Tray, Plastic L LINEX Capping-De-Capping Station

17 PHASER Consumables Graphite Ferrule for 0.25 mm column pk/ Graphite Ferrule for 0.32 mm column pk/ Graphite Ferrule for 0.53 mm column pk/ Graphite Vespel Ferrule for <0.25 mm column Graphite Vespel Ferrule for 0.25 mm column Graphite Vespel Ferrule for 0.32 mm column Graphite Vespel Ferrule for 0.53 mm column 0 17

18 PHASER Spare parts Glass Nose Cone Type Y Glass Nose Cone Type R sge SilFlow 4 Port Splitter 1.1mm Port sge sge sge sge sge sge sge sge sge SilFlow Nuts, pk/10 SilFlow Ferrules 1.1mm ID, Pk/5 SilFlow Ferrules 0.4mm ID, pk/10 SilFlow Ferrules 0.5mm ID, pk/10 SilFlow Ferrules 0.7mm ID, pk/10 SilFlow Ferrules 0.35mm ID, pk/10 SilTite FingerTite Tool SilFlow Ferrules 0.8mm ID SilFlow SS capillary Tubing 1.1 mm OD Sleeved to 1/16" 18

19 PHASER Spare parts Spare Fuse 250 V T 3 A 5.2 x 20 mm Spare Fuse 250 V T 5 A 5.2 x 20 mm, pk/ PFA Tubing 3.18 mm O.D. x 1.58 mm I.D. Pk/10 m Sulfinert Tubing 0.74 mm O.D. x 0.53 mm I.D. Pk/ 7,5 m Fused Silica Capillary Tubing mm I.D. x mm O.D. 0 m Fused Silica Capillary Tubing mm I.D. x mm O.D. 0 m Fused Silica Capillary Tubing mm I.D. x mm O.D. 0 m Fused Silica Capillary Tubing mm I.D. x mm O.D. 0 m Fused Silica Capillary Tubing mm I.D. x mm O.D. 0 m 19