IAC Acoustics Moduline Noise Control Enclosures. Mark Simnick

Size: px
Start display at page:

Download "IAC Acoustics Moduline Noise Control Enclosures. Mark Simnick"

Transcription

1

2 IAC Acoustics Moduline Noise Control Enclosures by Mark Simnick Mid-South Product Sales Manager IAC Acoustics, A Division of Sound Seal 401 Airport Road North Aurora, IL Mobile: (630) Office: (630) Toll Free: (800) Fax: (630) msimnick@soundseal.com Web Site:

3 Sound Seal is a leading manufacturer of commercial and architectural acoustic sound control products & materials. Offers a wide product selection to the acoustics & noise control markets. Over 37 years of expertise, Sound Seal can offer the technical support and know how to solve any noise problem. Sound Seal Agawam Ma Established: 1978 Dedicated staff to guide customers and project teams through step by step selection and specifications, ensuring we get it right the first time.

4 Sound Seal acquired INC, an acoustical metal panel company, in October 2014 Sound Seal acquired IAC Acoustics assets in December IAC Acoustics (Formerly INC)- North Aurora, IL Established: 1949 Moving forward the company will operate as IAC Acoustics, A Division of Sound Seal. INC s unique expertise with dyno room enclosures continues with INC Dyno Rooms offered by IAC Acoustics.

5 Presentation Topics IAC Acoustics company info. Moduline panel types and performances. Moduline key features. Moduline system components. Moduline enclosure applications. IAC Acoustics website & contacts. Questions and answers.

6 What will you learn? How IAC Moduline Enclosures solve noise control problems. How to choose the appropriate Moduline enclosure panel configuration. Available Moduline enclosure options and features. How to describe and specify Moduline enclosures. How IAC can provide you with additional information.

7 Moduline noise control enclosure systems shield people from loud equipment and processes and also create quiet zones within noisy environments.

8 The IAC Moduline system effectively blocks noise by STC 40 to as high as STC 70. Noise from equipment within the enclosure cannot escape. Noise on the outside of the enclosure cannot enter. Performance rated panels, floors, vibration isolation systems, doors, windows and ventilation systems all are required to maintain the acoustic integrity of the enclosure. Panels with both sound blocking and sound absorbing capability create an effective noise control enclosure. The enclosure needs to be air-tight. Even small holes will compromise performance. Modular design with acoustic details for simple and reliable installation.

9 STC-40 Sound Barrier NRC 1.05 STC- 40 Sound Absorber NRC 1.05 Absorption in combination with a reduction in transmission work together to minimize reflected and transmitted noise. Solid steel outer skin blocks air-borne sound. An inner surface with a perforated steel facing in front of sound absorptive insulation reduces reverberant build-up. Panels with both sound blocking and sound absorbing capability create an effective noise control enclosure. The enclosure needs to be air-tight. Even small holes will compromise performance. 1% opening will reduce the effectiveness by 10%.

10 Moduline Literature A wide range of noise control applications are detailed in the latest product application guide. Optimized performances with: Thickness of the solid skin. Added internal mass on the inside. Floating septums. Varied acoustic fills. STC 40 to STC 62, single wall. STC 70 with double wall Gemini construction. Underwriters Laboratories UL fire rated for 90 min and 60 min including joiners. IAC offers the greatest variety of standard panel constructions with lab rated performances.

11 Moduline Panel Performance A full range of STC ratings and panel types all fit the 4 modular system.

12 Most commonly used assembly: Moduline Noishield Regular 4 thickness STC-40 High NRC 16 ga. solid steel 22 ga. perf steel 8 lbs / sq ft Galvannealed and powder coated. Cold rolled steel and powder coat.

13 Moduline Joiners & Connectors Roll formed H joiner, single piece, no acoustic leaks. Acoustic insulation provided to fill voids in joints. Loading table included in Moduline Application Manual Moduline accommodates 4 x 4 tube steel posts for beams. Maximum panel length = 12 ft.

14 Moduline enclosures are compatible with high performance Noise-Lock sound rated doors. STC-51 to 55. Higher and lower performances are available. Doors integrate into panel joiner system. Noise-Lock windows and window panels are also available.

15 Moduline enclosures are compatible with acoustically treated ventilation systems. System details are included in the Moduline Application Manual. IAC QuietDuct silencers and fan systems can be included.

16 MIV-B system provides fan and QuietDuct silencers. Up to 8,000 CFM (std). IAC Quiet-Duct Model S silencers. 3 ft, 5 ft, 7 ft long silencers.

17 Key Moduline Benefits Predictable results with lab rated performance data. Most versatile set of panel configurations and performance data. Transmission loss data for 63 Hz and 8 khz bands. STC-40 to STC-70 Fire rated panels as complete system with joiners and doors. Modular design allows for future expansion and relocation. Fully integrated sound control doors, windows, ventilation systems all from same manufacturer. Integrated structural capability. High quality fit and finish for OEM presentation. Durable powder coated finish.

18 Moduline Enclosure Applications FCA Stamping Plant, Sterling, MI. Large stamping press enclosure for in-plant noise control. Moduline Noishield Regular, STC-40 acoustic performance. Sound control windows, doors, stairways. System included ventilation and lighting. Overall reduction of 20 dba.

19 Moduline Enclosure Applications Thermal spray enclosure for Metal Spray Concepts, St. Louis, MO. Extremely high sound levels, 120 dba+. Noise-Lock 1 panel construction, STC-44. Designed and fabricated by IAC, installed by customer.

20 Moduline Enclosure Applications Enerflex, TX skid mounted gas compressor equipment for Yale University. Moduline Noishield Regular, STC-40 acoustic performance. Integrated sound control doors, and ventilation system with acoustic treatment. Electrical, lighting, mechanical system pass-throughs all fully integrated. Fire suppression system included.

21 Moduline Enclosure Applications Beta Steel operator pulpit, Burns Harbor, Indiana. Moduline Noishield Regular, STC-40 acoustic performance. Large viewing windows to maximize visibility and safety. Pre-assembled construction, delivered as a single unit and lifted into place. Electrical, lighting, mechanical system connections fully integrated.

22 Industrial tab and Acoustic Enclosures section New Website and Literature

23 New Website and Literature

24 New Website and Literature

25 Also Installation literature!

26 IAC Acoustics Moduline Noise Control Enclosures Questions and Answers THANK YOU QUESTIONS? WOULD YOU LIKE A COPY OF THIS WEBINAR? msimnick@soundseal.com