MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

Size: px
Start display at page:

Download "MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA"

Transcription

1 Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) Proposed Addition (Slate Gray) MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

2 Proposed Rooftop Mechanical Screening (Slate Gray) Existing Yard Security Light Metal Siding(Cityscape) Trim (Matte Black) Existing Yard Security Light 14 4 Metal Awning (Matte Black) MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

3 Metal Siding(City Scape) Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Trim (Matte Black) Existing Yard Security Light Metal Awning (Matte Black) New Addition (Cityscape) MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

4 Existing Overhead Door Metal Siding(Cityscape) Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Trim (Matte Black) Existing Yard Security Light 14 Proposed Addition (Cityscape) MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

5 54 COLLEGE AVE - M R 2 SERVICES, INC. FLOOR PLAN - NO SCALE 14' 17' 3' 4' 12' 24' 6-1/2' UTILITY BATH BATH STORAGE - FUTURE OFFICE & MEETING ROOM 6-1/2' 4-1/2' 4-1/2' 24' 16-1/2' BREAK/MEETING ROOM & EXISTING OFFICE 52' 15-1/2' 52' 12' 12' 17' 3' 4' 12' 24'

6

7 Metal Systems Color Availability UNA-CLAD METAL PANEL COLOR SELECTION GUIDE Stone White Bone White Almond Sandstone Slate Gray Cityscape Charcoal Gray Sierra Tan Medium Bronze Dark Bronze Extra Dark Bronze Matte Black Brandywine Colonial Red Terra Cotta Mansard Brown Regal Red Award Blue Sky Blue Electric Blue Regal Blue Teal Patina Green Dark Ivy Sherwood Green Hartford Green Hemlock Green Tropical Patina Silver Metallic Classic Copper Champagne Metallic Colors shown are as close to actual painted steel as allowed by the printing process. Contact your local sales rep for actual metal samples.

8 CONCEALED FASTENED PANELS CFP-16F PANEL INDEX 16F - V0 BASE DETAILS VERTICAL PANELS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL WINDOW SILL DETAIL REFERENCE SHEETS VO.1 - PANEL PROFILE INFORMATION VA.1 - WINDOW OPENING ISOMETRIC VA.2 - PENETRATION ISOMETRIC VB.1 - PANEL / PANEL OVERLAP SPLICE TRANSITION OPTIONS EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED. IE: DETAIL 1 ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY. WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR / VAPOR BARRIERS WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES

9 CFP-16F - PROFILE 16F - V0.1 ITEM NUMBER: CFP-16F NET COVERAGE: 16" (1' 4") MAXIMUM LENGTH: (40 feet) MATERIAL OPTIONS COIL - COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM:.032" -.040" FINISH OPTIONS PAINTING "COIL COATED" HYLAR 5000 / KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES. ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY. NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT A CAUSE FOR REJECTION. 3. AN EXTENSIVE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FIRESTONE BUILDING PRODUCTS FOR UP TO DATE TECHNICAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED. V0.1

10 WALL ASSEMBLY TYPE 1 FACE OF PANEL TO SHT'G mm CFP-16F - BASE DETAIL 16F - V1.1 OVERALL WALL ASSEMBLY WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS CONTINUOUS HAT CHANNEL FASTENERS TYP. 1/8" x 1" PRE FINISHED BASE FLASHING WEEP HOLE LOCALIZED MEMBRANE METAL FLASHING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING STUD WALL INSULATION R-VALUE TO CODE INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSULATION INSIDE THE STUD WALL CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR BARRIER MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON INTERNATIONAL BUILDING CODE WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT BARRIER. V1.1

11 WALL ASSEMBLY TYPE 1 WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS CONTINUOUS HAT CHANNEL FASTENERS TYP. 1/8" x 1" PRE FINISHED BASE FLASHING FACE OF PANEL TO SHT'G mm CFP-16F - BASE DETAIL OVERALL WALL ASSEMBLY LOCALIZED MEMBRANE METAL FLASHING 16F - V1.1A SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING STUD WALL INSULATION R-VALUE TO CODE INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSULATION INSIDE THE STUD WALL CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR BARRIER MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON INTERNATIONAL BUILDING CODE WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT BARRIER. V1.1 OPTION A

12 WALL ASSEMBLY TYPE 2 CFP-16F - BASE DETAIL 16F - V1.2 OVERALL WALL ASSEMBLY WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS FACE OF PANEL TO SHT'G mm.500 MIN AIR SPACE 12.7 mm SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CONTINUOUS 'Z' GIRT INSULATION R-VALUE TO CODE LOCALIZED MEMBRANE STUD WALL FASTENERS TYP. 1/8" x 1" EXTERIOR SHEATHING INTERIOR DRYWALL METAL FLASHING VAPOR BARRIER "OPTIONAL" PRE FINISHED BASE FLASHING WEEP HOLE SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE V1.2

13 CFP-16F - BASE DETAIL 16F - V1.2A WALL ASSEMBLY TYPE 2 OVERALL WALL ASSEMBLY WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS FACE OF PANEL TO SHT'G mm.500 MIN AIR SPACE 12.7 mm SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CONTINUOUS 'Z' GIRT INSULATION R-VALUE TO CODE LOCALIZED MEMBRANE STUD WALL FASTENERS TYP. EXTERIOR SHEATHING 1/8" x 1" INTERIOR DRYWALL METAL FLASHING VAPOR BARRIER "OPTIONAL" PRE FINISHED BASE FLASHING SEALANT PRECAST WEEP TUBE & BAFFLE CONCRETE V1.2 OPTION A

14 WALL ASSEMBLY TYPE 1 CFP-16F - HORIZONTAL JOINT DETAIL 16F - V2.1 CFP - 16F VERTICAL PANELS WATER-RESISTIVE BARRIER FASTENERS TYP. CONT BUTYL SEALANT CONTINUOUS HAT CHANNEL CFP - 16F VERTICAL PANELS 4.00" MIN LAP LOCALIZED MEMBRANE STUD WALL SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS INSULATION R-VALUE TO CODE INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" EXTERIOR SHEATHING FACE OF PANEL TO SHT'G mm OVERALL WALL ASSEMBLY V2.1

15 WALL ASSEMBLY TYPE 1 CFP-16F - TRANSITION OPTIONS 16F - V2.1A 2.000" 50.8mm.125" 3.2mm V2.1A

16 WALL ASSEMBLY TYPE 1 CFP-16F - TRANSITION OPTIONS 16F - V2.1B 2.000" 50.8mm 5.000" 127.0mm 1.000" 25.4mm 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm.125" 3.2mm V2.1B

17 WALL ASSEMBLY TYPE 2 CFP-16F - HORIZONTAL JOINT DETAIL 16F - V2.2 STUD WALL CFP - 16F VERTICAL UPPER PANEL WATER-RESISTIVE BARRIER FASTENERS TYP. BUTYL SEALANT 4.00" MIN LAP LOCALIZED MEMBRANE CONTINUOUS 'Z' GIRT INSULATION R-VALUE TO CODE SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" EXTERIOR SHEATHING CFP - 16F VERTICAL LOWER PANEL mm.500 MIN AIR SPACE 12.7 mm FACE OF PANEL TO SHT'G OVERALL WALL ASSEMBLY V2.2

18 WALL ASSEMBLY TYPE 2 CFP-16F - TRANSITION OPTIONS 16F - V2.2A mm FLR SLAB mm V2.2A

19 WALL ASSEMBLY TYPE 2 CFP-16F - TRANSITION OPTIONS 16F - V2.2B 2.000" 50.8mm 5.000" 127.0mm 1.000" 25.4mm 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm.125" 3.2mm 5" EXTRUDED TRANSITION STRIP w/ FLAT FACE CFP - HORIZONTAL PANELS - OPTION "C" V2.2B

20 WALL ASSEMBLY TYPE 2 CFP-16F - PARAPET ROOF DETAIL 16F - V3.1 PRE FINISHED COPING LOCALIZED MEMBRANE ROOFING MEMBRANE 'Z' FLASHING WOOD BLOCKING 1/8" x 1" CONT SLOT PANEL AT THIS FASTENER TO ALLOW FOR THERMAL EXPANSION SEAL W/ SEAL or TAPE EDGES SEAL CONTINUOUS or TAPE EDGES AND ALL PENETRATIONS CONTINUOUS AND PERALL PENETRATIONS MANUF. RECOMMENDATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE STUD WALL EXTERIOR SHEATHING CONTINUOUS HAT CHANNEL CFP - 16F VERTICAL PANELS FIRE RATED PLYWOOD WATER-RESISTIVE BARRIER FACE OF PANEL TO SHT'G mm OVERALL WALL ASSEMBLY VAPOR BARRIER "OPTIONAL" V3.1

21 WALL ASSEMBLY TYPE 2 CFP-16F - PARAPET ROOF DETAIL 16F - V3.2 ROOFING MEMBRANE WOOD BLOCKING PRE FINISHED COPING LOCALIZED MEMBRANE 1/8" x 1" CONT 'Z' FLASHING LOCALIZED MEMBRANE SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS SLOT PANEL AT THIS FASTENER TO ALLOW FOR THERMAL EXPANSION SEAL W/ CFP - 16F VERTICAL PANELS CONTINUOUS HAT CHANNEL EXTERIOR SHEATHING STUD WALL RATED PLYWOOD WATER-RESISTIVE BARRIER VAPOR BARRIER "OPTIONAL" mm.500 MIN AIR SPACE 12.7 mm FACE OF PANEL TO SHT'G OVERALL WALL ASSEMBLY V3.2

22 WALL ASSEMBLY TYPE 1 CFP-16F - INSIDE CORNER DETAIL 16F - V4.1 1/8" x 1" CONT VAPOR BARRIER "OPTIONAL" " 88.9mm PRE FINISHED INSIDE CORNER CONTINUOUS HAT CHANNEL 1/8" x 1" CONT BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) INTERIOR DRYWALL INSULATION R-VALUE TO CODE EXTERIOR SHEATHING STUD WALL WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS FACE OF PANEL TO SHT'G mm OVERALL WALL ASSEMBLY V4.1

23 WALL ASSEMBLY TYPE 1 CFP-16F - INSIDE CORNER OPTION 16F - V4.1A 2.375" 60.3mm MIN FLASHING 1/8" x 1" CONT ALUM EXTRUSION 2.000" 50.8mm SET EXTRUSION IN A BED OF SEALANT ALUM EXTRUSION 1/8" x 1" CONT V4.1A

24 WALL ASSEMBLY TYPE 1 CFP-16F - INSIDE CORNER OPTION 16F - V4.1B 1/8" x 1" CONT 2.000" 50.8 mm ALUM EXTRUSION ALUM EXTRUSION V4.1B

25 WALL ASSEMBLY TYPE 2 CFP-16F - INSIDE CORNER DETAIL 16F - V4.2 1/8" x 1" CONT INSULATION R-VALUE TO CODE INSULATION R-VALUE TO CODE 3.500" 88.9mm PRE FINISHED INSIDE CORNER 1/8" x 1" CONT BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) EXTERIOR SHEATHING STUD WALL WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS CONTINUOUS 'Z' GIRT mm.500 MIN AIR SPACE 12.7 mm FACE OF PANEL TO SHT'G V4.2

26 WALL ASSEMBLY TYPE 2 CFP-16F - INSIDE CORNER DETAIL 16F - V4.2A 2.375" MIN 60.3mm 1/8" x 1" CONT NON CURRING INSULATION R-VALUE TO CODE EXTERIOR SHEATHING ALUM EXTRUSION ALUM EXTRUSION 2.000" 50.8mm STUD WALL WATER-RESISTIVE BARRIER FINISHED FLASHING CFP - 16F VERTICAL PANELS CONTINUOUS 'Z' GIRT V4.2A

27 WALL ASSEMBLY TYPE 2 CFP-16F - INSIDE CORNER OPTION 16F - V4.2B 2.000" 50.8 mm ALUM EXTRUSION ALUM EXTRUSION V4.2B

28 WALL ASSEMBLY TYPE 1 FACE OF PANEL TO SHT'G CFP-16F - OUTSIDE CORNER DETAIL 16F - V mm OVERALL WALL ASSEMBLY STUD WALL EXTERIOR SHEATHING WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS INSULATION R-VALUE TO CODE VAPOR BARRIER "OPTIONAL" INTERIOR DRYWALL 1/8" x 1" CONT CONTINUOUS HAT CHANNEL BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) PRE FINISHED OUTSIDE CORNER 4.750" 120.7mm 1/8" x 1" CONT CFP - 16F VERTICAL PANELS V5.1

29 WALL ASSEMBLY TYPE 1 CFP-16F - OUTSIDE CORNER OPTION 16F - V5.1A COMPRESSIVE GASKET SET EXTRUSION IN A BED OF SEALANT ALUM EXTRUSION ALUM EXTRUSION 4.000" 101.6mm DELTA SERIES PANEL V5.1A

30 WALL ASSEMBLY TYPE 1 CFP-16F - OUTSIDE CORNER OPTION 16F - V5.1B DELTA SERIES PANEL COMPRESSIVE GASKET ALUM EXTRUSION ALUM EXTRUSION FINISHED FLASHING 2.000" 50.8mm V5.1B

31 WALL ASSEMBLY TYPE 2 WATER-RESISTIVE BARRIER STUD WALL CFP-16F - OUTSIDE CORNER DETAIL 16F - V5.2 EXTERIOR SHEATHING INSULATION R-VALUE TO CODE VAPOR BARRIER "OPTIONAL" CFP - 16F VERTICAL PANELS INTERIOR DRYWALL 1/8" x 1" CONT FASTENERS TYP. CONTINUOUS 'Z' GIRT BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED).500 MIN AIR SPACE 12.7 mm mm FACE OF PANEL TO SHT'G OVERALL WALL ASSEMBLY PRE FINISHED INSIDE CORNER 6.500" 165.1mm 1/8" x 1" CONT CFP - 16F VERTICAL PANELS V5.2

32 WALL ASSEMBLY TYPE 2 CFP-16F - OUTSIDE CORNER DETAIL 16F - V5.2A COMPRESSIVE GASKET ALUM EXTRUSION ALUM EXTRUSION CONTINUOUS 'Z' GIRT 4.000" 101.6mm DELTA SERIES PANEL V5.2A

33 WALL ASSEMBLY TYPE 2 CFP-16F - OUTSIDE CORNER DETAIL 16F - V5.2B FINISHED FLASHING DELTA SERIES PANEL COMPRESSIVE GASKET ALUM EXTRUSION ALUM EXTRUSION CONTINUOUS 'Z' GIRT 1/8" x 1" CONT 2.000" 50.8mm V5.2B

34 WALL ASSEMBLY TYPE 1 CFP - 16F VERTICAL PANELS WATER-RESISTIVE BARRIER SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CFP-16F - SOFFIT DETAIL 16F - V6.1 STUD WALL INSULATION R-VALUE TO CODE INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" FASTENERS TYP. 1/8" x 1" CONT LOCALIZED MEMBRANE CONTINUOUS HAT CHANNEL 1/8" x 1" CONT OVERALL WALL ASSEMBLY PRE FINISHED BASE FLASHING mm WEEP HOLE PRE FINISHED SOFFIT FLASHING CFP - 16F VERTICAL PANELS EXTERIOR SHEATHING FACE OF PANEL TO SHT'G V6.1

35 WALL ASSEMBLY TYPE 2 FACE OF PANEL TO SHT'G mm CFP-16F - SOFFIT DETAIL 16F - V6.2 OVERALL WALL ASSEMBLY.500 MIN AIR SPACE 12.7 mm STUD WALL INSULATION R-VALUE TO CODE INTERIOR DRYWALL CFP - 16F VERTICAL PANELS WATER-RESISTIVE BARRIER SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE FASTENERS TYP. VAPOR BARRIER "OPTIONAL" 1/8" x 1" CONTINUOUS 'Z' GIRT 1/8" x 1" CONT PRE FINISHED BASE FLASHING WEEP HOLE PRE FINISHED BASE FLASHING CFP - 16F VERTICAL PANELS EXTERIOR SHEATHING V6.2

36 WALL ASSEMBLY TYPE 1 CFP-16F - WINDOW JAMB DETAIL 16F - V7.1 EXTERIOR SHEATHING WATER-RESISTIVE BARRIER STUD WALL INSULATION R-VALUE TO CODE VAPOR BARRIER "OPTIONAL" INTERIOR DRYWALL LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM 1/8" x 1" OVERALL WALL ASSEMBLY PREFINISHED JAMB TRIM BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) 3.000" 76.2mm 1/8" x 1" CONT BUTYL CONTINUOUS HAT CHANNEL CFP - 16F VERTICAL PANELS mm FACE OF PANEL TO SHT'G V7.1

37 WALL ASSEMBLY TYPE 2 CFP-16F - WINDOW JAMB DETAIL 16F - V7.2 WATER-RESISTIVE BARRIER STUD WALL EXTERIOR SHEATHING INSULATION R-VALUE TO CODE VAPOR BARRIER "OPTIONAL" INTERIOR DRYWALL LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM PREFINISHED JAMB TRIM 1/8" x 1" CONTINUOUS 'Z' GIRT.500 MIN AIR SPACE 12.7 mm mm FACE OF PANEL TO SHT'G OVERALL WALL ASSEMBLY BUTYL / HOTMELT SEALANT (FACTORY OR FIELD APPLIED) 3.000" 76.2mm 1/8" x 1" CONT CFP - 16F VERTICAL PANELS V7.2

38 CFP-16F - WINDOW HEAD DETAIL 16F - V8.1 WALL ASSEMBLY TYPE 1 OVERALL WALL ASSEMBLY FACE OF PANEL TO SHT'G mm EXTERIOR SHEATHING LOCALIZED MEMBRANE CONTINUOUS HAT CHANNEL SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS STUD WALL INSULATION R-VALUE TO CODE CFP - 16F VERTICAL PANELS FASTENERS TYP. PREFINISHED 'J' TRIM WEEP HOLE SEALANT PREFINISHED FLASHING 1/8" x 1" CONT WEEP TUBE & BAFFLE WINDOW/DOOR SYSTEM WATER-RESISTIVE BARRIER VAPOR BARRIER "OPTIONAL" INTERIOR DRYWALL LOCALIZED MEMBRANE V8.1

39 WALL ASSEMBLY TYPE 1 CFP-16F - WINDOW HEAD DETAIL 16F - V8.1A OVERALL WALL ASSEMBLY FACE OF PANEL TO SHT'G mm EXTERIOR SHEATHING LOCALIZED MEMBRANE CONTINUOUS HAT CHANNEL SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS STUD WALL INSULATION R-VALUE TO CODE CFP - 16F VERTICAL PANELS 1/8" x 1" CONT WATER-RESISTIVE BARRIER VAPOR BARRIER "OPTIONAL".125" INTERIOR DRYWALL PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.1 OPTION A

40 WALL ASSEMBLY TYPE 2 CFP-16F - WINDOW HEAD DETAIL 16F - V8.2 OVERALL WALL ASSEMBLY FACE OF PANEL TO SHT'G WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS mm.500 MIN AIR SPACE 12.7 mm STUD WALL INSULATION R-VALUE TO CODE CONTINUOUS 'Z' GIRT LOCALIZED MEMBRANE SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS FASTENERS TYP. WATER-RESISTIVE BARRIER 1/8" x 1" VAPOR BARRIER "OPTIONAL" PRE FINISHED BASE FLASHING WEEP TUBE & BAFFLE INTERIOR DRYWALL EXTERIOR SHEATHING WEEP HOLE SEALANT PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.2

41 WALL ASSEMBLY TYPE 2 FACE OF PANEL TO SHT'G WATER-RESISTIVE BARRIER CFP - 16F VERTICAL PANELS CONTINUOUS 'Z' GIRT mm CFP-16F - WINDOW HEAD DETAIL.500 MIN AIR SPACE 12.7 mm OVERALL WALL ASSEMBLY 16F - V8.2A STUD WALL INSULATION R-VALUE TO CODE SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE WATER-RESISTIVE BARRIER FASTENERS TYP. 1/8" x 1".125" 1/8" x 1" CONT VAPOR BARRIER "OPTIONAL" INTERIOR DRYWALL EXTERIOR SHEATHING PREFINISHED FLASHING WINDOW/DOOR SYSTEM LOCALIZED MEMBRANE V8.2 OPTION A

42 WALL ASSEMBLY TYPE 1 CFP-16F - WINDOW SILL DETAIL 16F - V9.1 WINDOW/DOOR SYSTEM SILL TRIM SILL TRIM CLIP (BY SILL TRIM INSTALLER) FASTENERS TYP. CONTINUOUS HAT CHANNEL LOCALIZED MEMBRANE CFP - 16F VERTICAL PANELS SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS INTERIOR DRYWALL VAPOR BARRIER "OPTIONAL" WATER-RESISTIVE BARRIER INSULATION R-VALUE TO CODE STUD WALL EXTERIOR SHEATHING FACE OF PANEL TO SHT'G mm OVERALL WALL ASSEMBLY V9.1

43 WALL ASSEMBLY TYPE 2 CFP-16F - WINDOW SILL DETAIL 16F - V9.2 WINDOW/DOOR SYSTEM SILL TRIM SILL TRIM CLIP (BY SILL TRIM INSTALLER) LOCALIZED MEMBRANE CFP - 16F VERTICAL PANELS CONTINUOUS 'Z ' GIRT VAPOR BARRIER "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS WATER-RESISTIVE BARRIER INSULATION R-VALUE TO CODE STUD WALL EXTERIOR SHEATHING INTERIOR DRYWALL mm.500 MIN AIR SPACE 12.7 mm FACE OF PANEL TO SHT'G OVERALL WALL ASSEMBLY V9.2

44 WALL ASSEMBLY TYPE 1 CFP-16F - VERTICAL TRANSITIONS 16F - V10.1 VHB TAPE 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm.563" 14.3mm 3.000" 76.2mm V10.1

45 WALL ASSEMBLY TYPE 1 CFP-16F - VERTICAL TRANSITIONS 16F - V10.2 VHB TAPE 5.000" 127.0mm ALUM EXTRUSION ALUM EXTRUSION 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm V10.2

46 WALL ASSEMBLY TYPE 1 CFP-16F - VERTICAL TRANSITIONS 16F - V10.3 ALUM EXTRUSION ALUM EXTRUSION 5.000" 127.0mm V10.3

47 CFP-16F - WDW OPENING 16F - VA.1 TYPICAL WINDOW OPENING APPLICATION SEALANTS NOT SHOWN FOR CLARITY METAL STUD WATER RESISTIVE BARRIER EXTERIOR SHEATHING FURRING OR GIRT "AS REQ'D" BY CODE LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING JAMB TRIM LOCALIZED FLEXIBLE MEMBRANE METAL STUD METAL SILL FLASHING LOCALIZED FLEXIBLE MEMBRANE WATER RESISTIVE BARRIER VA.1

48 CFP-16F - PENETRATION 16F - VA.2 TYPICAL BEAM PENETRATION APPLICATION SEALANTS NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS METAL STUD FURRING OR GIRT "AS REQ'D" BY CODE EXTERIOR SHEATHING LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING ATTACHMENT FLANGE STRUCTURAL MEMBER CLOSURE PLATE WET SEAL CUT OUT PERIMETER LOCALIZED FLEXIBLE MEMBRANE METAL STUD EXTERIOR SHEATHING WATER RESISTIVE BARRIER VA.2

49 CFP-16F - PANEL SPLICE TYPICAL PANEL / PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE 16F - VB.1 NOTE: WHEN LAPPING PANEL 'D' OVER 'A' THE LEFT FASTENER FLANGE AND RIGHT HOOK FEATURE AT THE BOTTOM OF THE UPPER PANEL IS NOTCHED BACK TO CLEAR THE TOP OF THE LOWER PANEL. WALL ASSEMBLY EXTERIOR SHEATHING WATER RESISTIVE BARRIER STARTER STRIP "AS REQ'D" FURRING OR GIRT "AS REQ'D" BY CODE TOP OF LOWER PANEL NON-CURRING BUTYL SEAL 4" LAP MINIMUM NOTCHED UPPER PANEL LOWER PANEL INSTALL DIAGRAM VB.1