1 T: F: E: South African Heritage Resources Agency - Head Office 111 Harrington Street Cape Town P.O. Box 4637 Cape Town 8001 Bill of Quantities Project: Tenant Installations Address: Suncadia, First Floor, Pretoria SAHRA/FAC/01/05/

2 BILL NO. 1 The contractor shall carry out the whole of the works with as little mess and noise as possible and with a minimum of disturbance to adjoining premises and their tenants. He shall provide proper protection and provide, erect and remove when directed, any temporary tarpaulins that may be necessary during the progress of the works, all to the satisfaction of the principal agent CONCRETE, FORMWORK AND REINFORCEMENT Preambles For Preambles see "Model Preambles for Trades". Supplementary Preambles REINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES 25 MPa, 19mm stone in: 1 125mm thick concrete slab m³ 1 REINFORCEMENT Mesh reinforcement 2 Steel mesh reinforcement reference No. 395 in concrete surface beds, slabs, etc. m²

3 BILL NO. 2 MASONRY Preambles For Preambles see "Model Preambles for Trades". Supplementary Preambles Brickwork: Sizes in descriptions Where sizes in descriptions are given in brick units, "one brick" shall represent the length and "half brick" the width of a brick SUPERSTRUCTURE BRICKWORK Clay brickwork of NFP bricks in class II mortar 1 Half brick walls m² One brick walls m² BRICKWORK SUNDRIES Brickwork reinforcement mm Wide brickwork reinforcement built in horizontally m mm Wide brickwork reinforcement built in horizontally m Pre-cast prestressed fabricated lintels 5 110x75mm lintels in lengths not exceeding 3m m

4 BILL NO. 3 PARTITIONS GypRoc Drywall partition systems Partitions consisting of 64mm steel studs inserted at 600mm centres into 64mm Drywall steel track at top and bottom clad on both sides as described, including additional studs as necessary at abutments, ends, etc, Boards shall be fixed in strict accordance with the manufacturer's instructions and all joints shall be taped and jointed mm high steel stud partitions with both sides clad with 12mm "Rhinoboard" Partition boards including taping and skimming on joints with bottom and top tracks plugged m²

5 BILL NO. 4 CARPENTRY AND JOINERY DOORS, PANELS, ETC Internal timber doors 1 Masonite timber doors 813 x 2032mm high to single door openings No 9.00 SKIRTINGS, CILLS, ETC Pine skirtings 2 70 x 12mm pine skirtings to wall linings m KITCHEN CUPBOARDS 3 Allow for Kitchen cupboards with "American Walnut" finishes or similar approved of overall length approx. 4250mm and height of 1100mm m Allow for granite tops as covers to kitchen cupboard 600mm wide m

6 BILL NO. 5 IRONMONGERY IRONMONGERY TO TIMBER DOORS Locks, Locksets, Hinges, etc Nylon washered aluminium hinges to timber door frames No Three lever mortice locksets, complete with stainless steel handles fixed to timber doors No 7.00 Three lever mortice locksets, complete with stainless steel handles fixed to paraplegic timber doors No mm rubber door stop fixed to floors No Bathroom fittings Stainless steel 2 roll Lockable toilet roll holder No

7 BILL NO. 6 METALWORK DOOR FRAMES, DOORS, WINDOWS, ETC Aluminium door frames hung to drywall partitions 1 Aluminium door frame, including building in to partition walls to suite single door opening 813 x 2032mm high No 5.00 PRESSED STEEL DOOR FRAMES 1,6mm Double rebated frames suitable for half brick walls complete with Howick HO36R 100 x 75mm brass butt hinges with nylon washers 2 For door size 813 x 2032mm high, 40mm thick No 4.00 ALUMINIUM SHOPFRONTS Epoxy powder coated shopfronts, complete with subframes, ironmongery, glass, sealing, etc and fixing to drywalling 3 Aluminium shopfronts - supplied, installed complete m²

8 BILL NO. 7 TILING WALL TILING Supply, delivery and fixing of 200 x 200mm white ceramic tiles, complete including adhesives, grout etc. 1 On walls FLOOR TILING m² 4.00 Supply, delivery and fixing of 600 x 600mm common porcelain tiles, complete including adhesives, grout etc. 2 On floors Porcelain tile skirtings, 100mm high m² mm hile tile skirting m Edge strips, corner protectors, stair nosings, expansion joint, strips etc 4 Aluminium edge strips to top of tile skirtings m

9 BILL NO. 08 PLASTERING INTERNAL PLASTER 15mm Plaster 1 To walls m²

10 BILL NO. 09 PLUMBING AND DRAINAGE SANITARY PLUMBING Supply, delivery and installation of all sanitary plumbing, complete including piping, chasing into brick walls, lagging, fittings and connections. (Waste and traps measured elsewhere) 1 15mm Cold Water supply points No mm hot and cold water supply points No mm grey water drainage points No 7.00 SANITARY FITTINGS Sanitary fittings to include supply and fixing of all sanware 'Franke' Double bowl sink including hot and cold tap, waste etc No x 310 x 110mm Macneil Freestanding Basin, including waste and trap No 2.00 Beta Courier wall-hung basin including waste and trap No

11 7 550 x 370 x 460mm Macneil Wall hung Pan Sorrento (installed with Giberet system) - including actuator plate No Vaal Protea Paraplegic low level suite No Vaal Poteries flat back wall mounted bowl urinal with concealed hanging bracket, exposed flush master flush valve No 1.00 TAPS, VALVES ETC. Mixers, taps etc 10 Cobra Noka Tap No Tap : Cobra B Elbow action mixer tap No

12 BILL NO. 10 GLAZING Preambles For preambles see "Model Preambles for Trades" Supplementary Preambles Tenderers are to provide an allowance for protection of glass as all scratched or damaged glass will have to be replaced MIRRORS Wall hung mirrors complete with all necessary frames, hoists, mounting brackets etc x 600mm mirrors No

13 BILL NO. 11 PAINTWORK ON INTERNAL FLOATED PLASTER SURFACES Prepare surface and apply one coat plaster primer, one universal undercoat and two coats Light grey Dulux Trade To walls m² Prepare surface and apply one coat plaster primer, one universal undercoat and two coats Dark grey Dulux Trade To walls m² 8.00 ON PLASTERBOARD SURFACES Prepare surface and apply one coat plaster primer, one universal undercoat and two coats Light grey Dulux Trade Internal drywall surfaces m² Bulkheads m²

14 Prepare surface and apply one coat plaster primer, one universal undercoat and two coats Dark grey Dulux Trade Internal drywall surfaces m² ON METAL One coat metal primer and 2 coats PSB 700 paint 6 On door frames m² 4.00 ON WOOD SURFACES WITH ENAMEL WOOD PAINT One coat Primer and two coats Dulux Labrador Sands 3 paint for intrior use 7 To timber doors m² To pine skirtings m

15 BILL NO. 12 PROVISIONAL SUMS Preambles For preambles see "Model Preambles for Trades" ELECTRICAL INSTALLATIONS GENERAL LIGHTING AND POWER Electrical connections, lighting, and plugs to suite 1 Allow a Provisional sum for the supply and fitting of power sockets, power poles/pedestal plug points, occupancy sensors, light fittings, light switches including all necessary wiring and connection to the existing power supply m² MECHANICAL WORK AIR CONDITIONING INSTALLATION 2 Midwall split units for individual offices and server rooms including hideaway split for open plan. m²

16 ITEM DESCRIPTION Page AMOUNT SUMMARY 1 PRELIMINARY & GENERAL Page 2 2 CONCRETE, FORMWORK AND REINFORCEMENT Page 2 3 MASONRY Page 3 4 PARTITIONS AND ACCESS FLOORING Page 4 5 CARPENTRY AND JOINERY Page 5 6 IRONMONGERY Page 6 7 METALWORK Page 7 8 TILING Page 8 9 PLASTERING Page 9 10 PLUMBING AND DRAINAGE Page GLAZING Page PAINTWORK Page PROVISIONAL SUMS Page PROFESSIONAL FEES (Estimated at 5%) 17 CONTINGENCY (Estimated at 8%) SUBTOTAL 1 SUBTOTAL 2 TOTAL EXC VAT 18 VAT AT 15 % TOTAL CONSTRUCTION COST (INCL VAT) 16