WD66 The Standard Wood Framed Folding System

Size: px
Start display at page:

Download "WD66 The Standard Wood Framed Folding System"

Transcription

1 INTRODUCTION WD66 WD66 The Standard Wood Framed Folding System Weather Resistant Life Cycle Performance Engineered to provide high weather resistance and structural performance. Excellent results were achieved with independent testing per AAMA/WDMA /CSA 100/I.S.2/ A440, NAFS North American Fenestration Standard. See Performance Testing Results pages. The WD66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. For benefits of all NanaWall systems, see the General Introduction section. For features common to wood folding systems, see the Wood Folding Systems Introduction. The standard system is top hung, where the main weight is carried by the head track. The bottom track is a guide. NFRC-Approved Thermal Performance The WD66 has been rated, certified and labeled in accordance with NFRC 100 and 200; see the Performance and Testing Results section for more details. and 1 1/2 triple glazing available. Energy Star values can be met with selected glazing. Florida Approval Option of Top Hung (WD66/o) or Floor Supported System (WD66/u) The floor supported system is recommended for applications where the vertical load bearing capability of the header is a concern. The main weight is carried by the floor track. The upper track is merely a guide. Acoustical Performance A five panel WD66 unit has been tested by an independent acoustic lab for acoustical performance. The WD66 with STC 38 laminated glass achieved STC and Rw values of 37. The WD66 is Florida statewide approved with Product Approval number FL This information with limitations can be viewed at 1

2 TECHNICAL DESCRIPTION WD66 General Description The WD66 is the standard commercial and/or residential folding or paired-panel wood framed system designed to provide an opening glass wall or storefront for widths up to 39 (12 m); see Maximum Size Chart. It is available in various configurations utilizing one to twelve panels; see elevation drawings. The option exists for a swing entry/exit panel(s). Units can be either inward-opening or outward-opening; see section drawings. Frame and Panels The three-layer, cross grained, solid wood panel frame thickness is 2 5/8 (66 mm) or 3 1/16 (78 mm); see various frame profiles in section drawings. The aluminum head jamb of the WD66/o system is clad with matching wood fascia pieces on both sides. Standard woods are European Pine, Douglas Fir or Meranti. Other woods are also available. Frames and panels have a sanding sealer or a base coat applied to be field finished by others; see Wood Finish Options in the General introduction. Panels are preassembled. All pins and screws to assemble the frame are provided. The Raised Sill (higher weather performance sill), thermally broken aluminum with 3/4 (18.5 mm) wide polyamide plastic, and various flush sills are available in a clear or dark bronze anodized finish. Glazing Units can be supplied glazed with double insulating Low-E safety glass, clear double insulating safety, and 1 1/2 triple insulating Low-E safety, 1/4 (6 mm) single tempered or laminated, other high performing safety glass such as Heat Mirror, acoustic, special tint, etc., or other glass on request. Weatherstripping All weatherstripping consisting of EPDM or brush seals is provided for sealing between panels and between panels and frames; see section drawings. Sliding/Folding Hardware For sliding and folding of each pair of panels, for the WD66/o top hung system, a load-bearing, upper-running carriage and a lower-running guide carriage is attached between the two panels (shown in the section drawings). The double pair, twin-tandem, upper-running carriage is constructed to ensure even distribution of pressure on all four rollers. For the WD66/u floor supported system, a floor supported, lower running carriage and an upper running carriage as a guide is attached between the panels. Rollers have sealed bearings and are coated with toughened Polyamide to ensure sound-free running and optimal resistance to extreme temperature. Two to five patented clear or dark bronze anodized hinges per connection are provided to connect panels together and to connect panels to the frame. Locking Hardware and Handle Options For each pair of folding panels (except for the pair to be opened first in a unit with no swing panel), provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180º turn of a flat handle on the inside only. If there is a swing panel, there are the following hardware options on the primary swing panel: 1. Multi-point Locking. Consisting of lever handles on both sides, a lockset, lockable latch, deadbolt and rods at the top and the bottom. After turn of key or thumbturn, depression of handles withdraws latch, lifting of handles engages rods and turn of key or thumbturn engages deadbolt and locks. For a unit with a secondary swing panel, available are matching dummy lever handles on both sides and a concealed flush bolt that operates the rods at the top and the bottom. Available with profile cylinder or with SFIC adapter. 2. Deadbolt Lock. Consisting of push/pull handles on both sides with deadbolt(s) operated by a lockset. Turn of key or thumb turn operates lock. Available is a lockset option of having key operation on both sides. To keep the panel closed, a door closer should be field installed, but please note that a door closer can only be installed for a swing panel that is attached to the side jamb. 3. No Hardware. For panic hardware to be installed by others, the main entry panel can be supplied with no locking hardware. 2

3 TECHNICAL DESCRIPTION WD66 For a unit with no swing panel, on the folding pair to be opened first, provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180º turn of an L-shaped handle for an inward opening unit and a flat handle for an outward opening unit on the inside. In both cases, there will be a flat handle on the outside. Lockable with a lockset. Turn of key or thumb turn operates lock. Please note that for an outward opening unit, locking from the inside will need to be with a key that may not meet egress requirements. For a unit where locking/handles on the inside only is desired, like in window applications, on all swing panels or pair of folding panels to be opened first, provided is two point locking with a flat handle on the inside only. Handle Finish Schemes: Standard Stainless steel lever, flat, and L-shaped handles in brushed satin or black titanium finish. Push/pull handles are in brushed stainless steel. Optional Brass lever handles in oil rubbed brass or satin nickel, and flat handles powdercoated dark brown or silver gray. 3

4 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 TYPE OF TEST INWARD OPENING S OUTWARD OPENING S Air Infiltration q ASTM E-283, cfm/ft 1.57 psf (75 Pa): 0.08 (0.27 exfiltration) A psf (300 Pa): 1.57 psf (75 Pa): 0.04 (0.04 exfiltration) A psf (300 Pa): 0.18 Water Penetration q ASTM E 331 and ASTM E-547 No uncontrolled water 9 psf (440 Pa) DESIGN PRESSURE e No uncontrolled water 9 psf (440 Pa) DESIGN PRESSURE e Structural Load Deflection q ASTM E-330: pass See design windload charts for other sized panels Note that the structural test pressures were 50% higher than the design pressures psf (2000 Pa) 52.5 psf (2520 Pa) Class SP-PG40, Panel size - 3 x 8 (915 mm x 2471 mm)e 52.5 psf (2520 Pa) 41.5 psf (2000 Pa) Class SP-PG40, Panel size - 3 x 8 (915 mm x 2471 mm)e Life Cycle Performance The WD66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark The WD66 is CE Mark Certfied Forced Entry Resistance q In accordance with AAMA-1304 (1330 N (300 lbf) point load) requirements 4

5 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 with 66 mm Profile / Top Hung Units Acoustical Performance w The WD66 system has been tested by an independent acoustic lab for acoustical performance. the WD66 with STC 38 laminated glass achieved STC and Rw values of 37. q Excerpts of results of 9 7 W x 8 6 H three panel unit with Standard (Raised) sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in april 2013 per AAMA/WDMA/CSA 101/I.S.2/A440, NAFS North American Fenestration Standard. w Excerpts of results of a unit tested by Nusing Mobile Trennwandtechnile, Munster, Germany, an independent testing laboratory in August e For Canada, tested to NAFS-08 or equivalent and CSA A Rated, certified and labeled in accordance with NFRC Thermal Performance INWARD OPENING S 66 MM THICK PROFILE OUTWARD OPENING S TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY 2015 Double IG Clear (air filled) Double IG Standard Low E (argon filled) Ü Ü Double IG Standard Low E (air filled) _ Double IG Low E Alternate (argon filled) ÜÜ ÜÜ Double IG Low E Alternate (air filled) ,43 (argon filled) Ü Ü (air filled) Ü Ü 5

6 Standard (argon filled) Ü Ü Double IG Low E Standard (air filled) _ TESTING Double RESULTS IG Low E WD66.26 Alternate (argon filled) HIGHER WEATHER PERFORMANCE RAISED SILL ÜÜ ÜÜ Double IG Low E ,43 Alternate (air filled) Higher Weather Performance (Raised) Sill (argon filled) WD66 with 66 mm Profile / Floor Supported Units Ü Ü (air filled) Rated, certified and labeled in accordance with NFRC Ü Ü Thermal Performance (argon filled) 78 mm thick profile only TYPE OF GLASS (1 LITE) r Double IG Clear (air filled) CENTER OF GLASS Thermal Performance /2 (88 mm) IG GLASS THICKNESS INWARD OPENING S 66 MM THICK PROFILE ÜÜ ÜÜ OUTWARD OPENING S Rated, SHGC t certified VT y and labeled 2015 in accordance with NFRC ENERGY SHGC t VT y 2015 ENERGY 78 MM THICK PROFILE INWARD OPENING S OUTWARD OPENING S Double TYPE IG OF Low E Standard GLASS (argon (1 LITE) filled) r CENTER OF GLASS.26 IG GLASS THICKNESS ENERGY Ü Ü SHGC t VT y 2015 SHGC t VT y ENERGY 2015 Double IG Low Double IG Low E Standard (air filled) Standard (argon filled) _ Ü Ü Double IG Low Double IG Low E Alternate (argon filled) Standard (air filled) ÜÜ Ü ÜÜ Ü Double IG Low Triple IG Low E Alternate (air filled) Standard (argon filled) , Ü Ü Triple IG Low E (argon filled) Standard (air filled) Ü Ü Triple IG Low E (air filled) Alternate (argon filled) Ü Ü (argon Triple filled) IG Low 78 E mm Alternate thick profile (air only filled) 1/2 ( ÜÜ Ü ÜÜ Ü NOTES r NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher than units with no horizontal mullion. Please contact NanaWall for details. t SHGC = Solar Heat Gain Coefficient y VT = Visible Transmittance Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and <..40 in North/North Central zones. (for guidance only. NanaWall is not a participant of the Energy Star program.) ÜÜ Meets SHGC energy Star Qualification criteria for north/north central zones only. Call NanaWall for U-Factor & SHGC for other glass types Low Profile Saddle Sill WD66 6 TYPE OF TEST INWARD OPENING S OUTWARD OPENING S

7 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 with 78 mm Profile / Floor Supported Units Rated, certified and labeled in accordance with NFRC Thermal Performance INWARD OPENING S 78 MM THICK PROFILE OUTWARD OPENING S TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY 2015 Double IG Low E Standard (argon filled) Ü Ü Double IG Low E Standard (air filled) Ü Ü Triple IG Low E Standard (argon filled) Ü Ü Triple IG Low E Standard (air filled) Ü Ü Triple IG Low E Alternate (argon filled) Ü Ü Triple IG Low E Alternate (air filled) Ü Ü NOTES r NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher than units with no horizontal mullion. Please contact NanaWall for details. t SHGC = Solar Heat Gain Coefficient y VT = Visible Transmittance Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and <..40 in North/North Central zones. (for guidance only. NanaWall is not a participant of the Energy Star program.) ÜÜ Meets SHGC energy Star Qualification criteria for north/north central zones only. Call NanaWall for U-Factor & SHGC for other glass types Low Profile Saddle Sill WD66 TYPE OF TEST INWARD OPENING S OUTWARD OPENING S Air Infiltration q ASTM E-283,cfm/ft 1.57 w psf (75 Pa): 0.17 (0.17 exfiltration) A psf (75 Pa): 0.17 (0.05 exfiltration) A psf ( psf (300 Pa): 7

8 TESTING RESULTS WD66 LOW PROFILE SADDLE SILL Low Profile Saddle Sill WD66 TYPE OF TEST INWARD OPENING S OUTWARD OPENING S Air Infiltration q ASTM E-283,cfm/ft 1.57 w psf (75 Pa): 0.17 (0.17 exfiltration) A psf (300 Pa): 1.57 psf (75 Pa): 0.17 (0.05 exfiltration) A psf (300 Pa): 0.31 Water Penetration qw ASTM E-547 and E-331 Low Profile Saddle Sill (top hung system - internally tested) No uncontrolled water 5.43 psf (250 Pa) Subject to the following additional adaptations of the sill in the field by others: 1. Remove the gaskets covering the inner channel. 2. Drill weep holes through the bottom of this channel (about one 1 x 1/4 diameter weep hole per panel.) 3. Drill weep holes through the bottom of the sill or lower front face of the sill to drain water collected to a lower point (about one 1 x 1/4 weep hole per panel, or equivalent circular holes.) Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired, we recommend that a qualified professional construct this system on the project site strictly in accordance with nanawall instructions with good waterproofing techniques. if drain connections are not made or are not possible, unit may leak with wind driven rain. DESIGN PRESSURE w DESIGN PRESSURE w Positive Negative Positive Negative Structural Load Deflection q ASTM E-330: pass See design windload charts for other sized 45 psf ( psf (2630 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by 55 psf ( psf (2160 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by others) Forced Entry Resistance q in accordance with AAMA-1304 (1330N (300 lb) point load) Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. 8 European CE Mark WD66 is CE Mark Certified

9 Positive Negative Positive Negative Structural Load Deflection q ASTM E-330: pass See design windload charts for other sized panels TESTING RESULTS 45 psf ( psf (2630 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by 55 psf ( psf (2160 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by others) LOW PROFILE SADDLE SILL Forced Entry Resistance q Low Profile Saddle Sill in accordance with AAMA-1304 (1330N (300 lb) point load) WD66 with 66 mm Profile / Top Hung Units Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark WD66 is CE Mark Certified q Excerpts of results of 9 7 w x 8 6 h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in April 2013 per aama/wdma/csa101/i.s.2/a440, nafs-north American Fenestration Standard. w Inswing unit not tested. Results based on deduction from outswing unit test results. e For Canada, tested to NAFS-08 or equivalent and CSA A Rated, certified and labeled in accordance with NFRC Thermal Performance 66 MM THICK LOW PROFILE SADDLE SILL INWARD OPENING S OUTWARD OPENING S TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY 2015 Double IG Clear (air filled) Double IG Standard Low E (argon filled) Ü Ü Double IG Standard Low E (air filled) Double IG Alternate Low E (argon filled) ÜÜ ÜÜ Double IG Alternate Low E (air filled) (argon filled) Ü Ü (air filled) Ü Ü Rated, certified and labeled in accordance with NFRC Thermal Performance 66 MM THICK LOW PROFILE SADDLE SILL INWARD OPENING S OUTWARD OPENING S 9 TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY 2015 Double IG Clear

10 Double IG Alternate Low E (argon filled) Double IG Alternate Low E (argon filled) Double IG Alternate Low E (air filled) Double IG Alternate TESTING Low RESULTS E (air filled) WD66 (argon filled) (argon filled) (air filled) Triple (air IG filled) Low E x 2 (argon filled) 78 mm thick profile only ÜÜ ÜÜ ÜÜ ÜÜ LOW PROFILE SADDLE SILL Ü Ü Ü Ü Ü Ü Low Profile Saddle Sill Ü Ü WD66 with 66 mm Profile / Floor Supported Units Ü Ü Rated, certified and labeled in accordance with NFRC Thermal Performance Thermal Performance TYPE OF GLASS (1 LITE) r Double TYPE IG OF Clear GLASS (air (1 filled) LITE) r CENTER OF GLASS CENTER OF GLASS.48 IG GLASS THICKNESS IG GLASS THICKNESS Rated, certified and labeled in accordance with NFRC MM THICK LOW PROFILE SADDLE SILL INWARD OPENING S OUTWARD OPENING S 78 MM THICK FLUSH SILL SHGC t VT y 2015 ENERGY SHGC t VT y 2015 INWARD OPENING S OUTWARD OPENING S ENERGY.45 SHGC.46 t VT.49 y 2015 ENERGY.45 SHGC.46 t VT.49 y 2015 ENERGY Double Double IG IG Standard Low E Standard Low E (argon (argon filled) filled).26 ( Ü Ü Double IG Standard Double Low E (air IG Low filled) E Standard (air filled) (24 mm) Ü Ü Double IG Alternate Low E (argon filled) Triple IG Low E Standard (argon filled) Double IG Alternate Low E (air filled) Triple IG Low E Standard (air filled) (argon filled) ÜÜ ÜÜ Ü Ü Ü Ü Ü Ü Triple IG Low E Alternate Triple IG (argon Low E filled) x 2 (air filled) (38 mm) Ü Ü Ü Ü Triple Triple IG IG Low Low E E x 2 (argon Alternate filled) (air 78 filled) mm thick profile only (38 mm) Ü Ü NOTES r NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher than units with no horizontal mullion. Please contact nanawall for details. t SHGC = Solar Heat Gain Coefficient y VT = Visible Transmittance Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) ÜÜ Meets SHGC Energy Star Qualification criteria for North/North Central zones only. Call NanaWall for U-Factor & SHGC for other glass types 10

11 Double IG Alternate Double Low E IG (air Alternate filled) Low E (air filled) (24 mm) Triple (argon IG Low filled) E x 2 (argon filled) TESTING RESULTS WD66 Triple (air IG filled) Low E x 2 (air filled) (argon Triple IG filled) Low 78 E x mm 2 (argon thick filled) profile 78 only mm thick profile only (28 mm) (28 mm) Ü Ü Ü Ü LOW PROFILE SADDLE SILL Ü Ü Ü Ü Low Profile Saddle Sill Ü Ü Ü Ü WD66 with 78 mm Profile / Floor Supported Units Rated, certified and labeled in accordance with NFRC Rated, certified and labeled in accordance with NFRC Thermal Performance Thermal Performance CENTER TYPE OF CENTER GLASS TYPE (1 LITE) OF GLASS (1 LITE) r IG GLASS OF GLASS IG GLASS OF GLASS THICKNESS THICKNESS 78 MM THICK FLUSH SILL 78 MM THICK LOW PROFILE SADDLE SILL INWARD OPENING S OUTWARD OPENING S INWARD OPENING S OUTWARD OPENING S SHGC VT 2015 ENERGY SHGC VT 2015 SHGC t VT y 2015 ENERGY SHGC t VT y 2015 ENERGY ENERGY Double IG Low E Standard Double (argon IG Low filled) Standard (argon filled) (28 1/8 mm) Ü Ü Double IG Low E Standard Double IG (air Low filled) Standard (air filled) (28 1/8 mm) Ü Ü Triple IG Low E Standard Triple (argon IG Low filled) Standard (argon filled) (38 7/16 mm) Ü Ü Triple IG Low E Standard Triple IG (air Low filled) Standard (air filled) (38 7/16 mm) Ü Ü Triple IG Low E Alternate Triple (argon IG Low filled) Alternate (argon filled) (38 7/16 mm) Ü Ü Triple IG Low E Alternate Triple IG (air Low filled) Alternate (air filled) (38 7/16 mm) Ü Ü Flush Sill WD66 Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and TYPE <.40 OF in North/North TEST Central zones. (For guidance INWARD only. OPENING NanaWall is not S a participant of the OUTWARD Energy Star program.) OPENING S Air Infiltration q ASTM E-283,cfm/ft 2 NOTES r NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher than units with no horizontal mullion. Please contact nanawall for details. ÜÜ Meets SHGC Energy Star Qualification criteria for North/North Central zones 1.57 w psf (75 Pa): 0.17 (0.17 exfiltration) A2 e Call NanaWall for U-Factor & SHGC for other glass 6.24 psf (300 Pa): 0.18 t SHGC = Solar Heat Gain Coefficient y VT = Visible 1.57 psf (75 Pa): 0.17 (0.05 exfiltration) A psf (300 Pa): 0.31 Water Penetration qw ASTM E-547 and E-331 Flush Sill (similar conditions with low profile saddle sill with weepage from middle channel only) No uncontrolled water 2.92 psf (140 Pa) (similar conditions for standard flush sill) Subject 2016 to the Nana following Wall Systems, adaptations Inc. of the sill in the field by others: 1. Drill weep holes through the outer bottom wall in the middle channel (1 1/4 x 3/16 weep hole per panel) 2. Drill weep holes through the lower front face of the sill to drain water collected to a lower point (1 1/4 x 3/16 weep hole per panel) 11

12 TESTING RESULTS WD66 FLUSH SILL Flush Sill WD66 TYPE OF TEST INWARD OPENING S OUTWARD OPENING S Air Infiltration q ASTM E-283,cfm/ft 1.57 w psf (75 Pa): 0.17 (0.17 exfiltration) A psf (300 Pa): 1.57 psf (75 Pa): 0.17 (0.05 exfiltration) A psf (300 Pa): 0.31 Water Penetration qw ASTM E-547 and E-331 Flush Sill (similar conditions with low profile saddle sill with weepage from middle channel only) No uncontrolled water 2.92 psf (140 Pa) (similar conditions for standard flush sill) Subject to the following adaptations of the sill in the field by others: 1. Drill weep holes through the outer bottom wall in the middle channel (1 1/4 x 3/16 weep hole per panel) 2. Drill weep holes through the lower front face of the sill to drain water collected to a lower point (1 1/4 x 3/16 weep hole per panel) Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired, we recommend that a qualified professional construct this system on the project site strictly in accordance with nanawall instructions with good waterproofing techniques. if drain connections are not made or are not possible, unit may leak with wind driven rain. DESIGN PRESSURE w DESIGN PRESSURE w Positive Negative Positive Negative Structural Load Deflection q ASTM E-330: pass See design windload charts for other sized 45 psf ( psf (2630 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by 55 psf ( psf (2160 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by others) Forced Entry Resistance q in accordance with AAMA-1304 (1330N (300 lb) point load) Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark WD66 is CE Mark Certified 12 q Excerpts of results of 9 7 w x 8 6 h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in April 2013 per aama/wdma/csa101/i.s.2/a440, nafs-north American Fenestration Standard.

13 Positive Negative Positive Negative Structural Load Deflection q ASTM E-330: pass See design windload charts for other sized panels TESTING RESULTS 45 psf ( psf (2630 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by 55 psf ( psf (2160 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) w (weepholes by others) FLUSH SILL Forced Entry Resistance q Flush Sill in accordance with AAMA-1304 (1330N (300 lb) point load) WD66 with 66 mm Profile / Top Hung Units Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark WD66 is CE Mark Certified q Excerpts of results of 9 7 w x 8 6 h three panel units (3l and 3R configurations) with Raised Sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in April 2013 per aama/wdma/csa101/i.s.2/a440, nafs-north American Fenestration Standard. w Inswing unit not tested. Results based on deduction from outswing unit test results. e For Canada, tested to NAFS-08 or equivalent and CSA A Rated, certified and labeled in accordance with NFRC Thermal Performance 66 MM THICK FLUSH SILL INWARD OPENING S OUTWARD OPENING S TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY 2015 Double IG Clear (air filled) _ Double IG Standard Low E (argon filled) Ü Ü Double IG Standard Low E (air filled) _ Double IG Alternate Low E (argon filled) ÜÜ ÜÜ Double IG Alternate Low E (air filled) (argon filled) Ü Ü (air filled) Ü Ü Rated, certified and labeled in accordance with NFRC Thermal Performance TYPE OF GLASS (1 LITE) r CENTER OF GLASS IG GLASS THICKNESS 66 MM THICK FLUSH SILL INWARD 2016 Nana OPENING Wall Systems, S Inc. OUTWARD OPENING S SHGC t VT y ENERGY 2015 SHGC t VT y ENERGY

14 Double IG Alternate Low E (argon filled) ÜÜ ÜÜ Double IG Alternate Low E (air filled) TESTING RESULTS WD66 (argon filled) FLUSH SILL Ü Ü (air filled) (argon filled) 78 mm thick profile only Ü Ü Flush Sill WD66 with 66 mm Profile / Floor Supported Units Ü Ü Rated, certified and labeled in accordance with NFRC Thermal Performance Thermal Performance TYPE OF GLASS (1 LITE) r TYPE OF GLASS Double (1 IG LITE) Clear r (air filled) CENTER OF GLASS CENTER OF GLASS.48 IG GLASS THICKNESS IG GLASS THICKNESS Rated, certified and labeled in accordance with NFRC MM THICK FLUSH SILL INWARD OPENING 78 S MM THICK FLUSH OUTWARD SILL OPENING S SHGC t VT y 2015 ENERGY SHGC t VT y 2015 INWARD OPENING S OUTWARD OPENING S ENERGY SHGC t VT y 2015 ENERGY SHGC t VT y 2015 ENERGY Double Double IG IG Standard Low E Standard Low E (argon (argon filled) filled).26 ( Ü Ü Double IG Standard Double IG Low E Low E (air filled) Standard (air filled) Ü Ü Double IG Alternate Low Triple E (argon IG Low filled) E Standard (argon filled).26 (24 mm) ÜÜ ÜÜ Ü Ü Double IG Alternate Low E (air filled) Triple IG Low E Standard (air filled) (argon filled) Ü Ü Ü Ü Triple IG Low E Alternate Triple IG (argon Low E filled) x 2 (air filled) (38 mm) Ü Ü Ü Ü Triple Triple IG IG Low Low E E x 2 (argon Alternate filled) (air 78 filled) mm thick profile only (38 mm) Ü Ü NOTES Rated, certified and labeled in accordance with NFRC t SHGC 100 = + Solar 200 Heat Gain r NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher Coefficient than units with no horizontal mullion. Please contact nanawall for details. y VT = Visible Transmittance Thermal Performance TYPE OF GLASS (1 LITE) r 78 MM THICK FLUSH SILL Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) INWARD OPENING S OUTWARD OPENING S ÜÜ Meets SHGC Energy Star Qualification criteria for North/North Central zones only. CENTER IG GLASS OF GLASS SHGC THICKNESS t VT y 2015 ENERGY Call NanaWall for U-Factor & SHGC for other glass types SHGC t VT y ENERGY 2015 Double IG Low E Standard (argon filled) Ü Ü Double IG Low E Standard (air filled) Ü Ü Triple IG Low E Standard (argon filled) Triple IG Low E Standard (air filled) Ü Ü Ü Ü 14 Triple IG Low E

15 Double IG Alternate Double IG Alternate Low E (air filled) Low (air filled) Triple IG Low (argon filled) (argon filled) TESTING RESULTS WD66 1/8 Triple IG Low 1/8 (air filled) (air filled) Triple IG Low (argon filled) 78 mm (argon filled) 78 mm thick profile only thick profile only 7/ Ü Ü FLUSH SILL Ü Ü Flush Sill Ü Ü WD66 with 78 mm Profile / Floor Supported Units Rated, certified and labeled in accordance with NFRC Rated, certified and labeled in accordance with NFRC Thermal Performance MM MM THICK THICK FLUSH FLUSH SILL SILL INWARD INWARD OPENING OPENING S S OUTWARD OUTWARD OPENING OPENING S S TYPE OF TYPE OF GLASS (1 LITE) GLASS (1 LITE) r CENTER CENTER OF GLASS OF GLASS IG GLASS IG GLASS THICKNESS THICKNESS SHGC VT 2015 SHGC t VT y 2015 ENERGY ENERGY SHGC VT 2015 SHGC t VT y 2015 ENERGY ENERGY Double IG Low E Double IG Low Standard (argon filled) Standard (argon filled) / Ü Ü Double IG Low E Double IG Low Standard (air filled) Standard (air filled) 1/ Ü Ü Triple IG Low E Triple IG Low Standard (argon filled) Standard (argon filled) 7/ Ü Ü Triple IG Low E Triple IG Low Standard (air filled) Standard (air filled) 7/ Ü Ü Triple IG Low E Triple IG Low Alternate (argon filled) Alternate (argon filled) 7/ Ü Ü Triple IG Low E Triple IG Low Alternate (air filled) Alternate (air filled) 7/ Ü Ü NOTES NOTES r NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher NFRC simulated factors of units with horizontal mullion will have values of about.01 to.02 higher than units with no horizontal mullion. Please contact nanawall for details. than units with no horizontal mullion. Please contact nanawall for details. t SHGC = Solar Heat Gain SHGC Solar Heat Gain Coefficient Coefficient y VT = Visible Transmittance VT Visible Transmittance Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones Ü2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <, SHGC <25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) and <.40 in North/North Central zones. (For guidance only. NanaWall is not participant of the Energy Star program.) ÜÜ Meets SHGC Energy Star Qualification criteria for North/North Central zones only. ÜÜ Meets SHGC Energy Star Qualification criteria for North/North Central zones only. Call NanaWall for U-Factor & SHGC for other glass types Call NanaWall for U-Factor SHGC for other glass types 15

16 MAXIMUM SIZE CHART WD66 FRAME HEIGHT OF NUMBER OF PANELS IN 9 10 (3000) 9 6 (2900) 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 (2400) 7 6 (2300) 7 2 (2200) 6'10" (2100) and below '11" (600) 3'11" (1200 5"10" (1800) 7'10" (2400) 9'10" (3000) 11'9" (3600) 13'10" (4200) 15'8" (4800) 17'9" (5400) 19'8" (6000) 21'7" (6600) 23'6" (7200) NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters. 2 3 (700) 4 7 (1400) 6 10 (2100) 9 2 (2800) 11 5 (3500) (4200) 16 (4900) 18 4 (5600) 20 7 (6300) (7000) 25 1 (7700) 27 4 (8400) 2 7 (800) 5 3 (1600) 7 10 (2400) 10 6 (3200) 13 1 (4000) 15 8 (4800) 18 4 (5600) (6400) 23 6 (7200) 26 1 (8000) 28 8 (8800) 31 5 (9600) FRAME WIDTH OF A (900) 5 10 (1800) 8 10 (2700) 11 9 (3600) 14 9 (4500) 17 8 (5400) 20 7 (6300) 23 6 (7200) 26 5 (8100) 29 4 (9000) 32 5 (9900) 35 5 (10800) B A & B 3 3 (1000) 6 6 (2000) 9 10 (3000) 13 1 (4000) 16 4 (5000) 19 8 (6000) (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 36 1" (11000) 39 4" (12000) With 2 5/8" (66 mm) thick profile For Single Glass, Double and 1 1/8" Triple Insulated Glass - both top hung and floor supported systems Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width For heights above 8 4 (2550 mm), panels have to be stiffened with a horizontal mullion. (If no horizontal mullion is desired, please see size chart for 3 1/16" (78 mm) on page 7) A. For configurations hinged to a side jamb combined with a pair(s) of folding panels or for configurations with a pair(s) of folding panels only includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R, 2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R, 1L6R, 6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R. B. For all configurations. The maximum size limits are based on the maximum weight of a panel that has a net glass thickness of 5/16 (8 mm) or 5/32 (4 mm) for each glass pane. For thicker glass this maximum size limit chart will not apply. For configurations with only even number of panels stacking to each side, the minimum width of each panel is 2'3" (700 mm). 16

17 MAXIMUM SIZE CHART WD66 FRAME HEIGHT OF NUMBER OF PANELS IN 9 10 (3000) 9 6 (2900) 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 (2400) 7 6 (2300) 7 2 (2200) 6'10" (2100) and less '11" (600) 3'11" (1200 5"10" (1800) 7'10" (2400) 9'10" (3000) 11'9" (3600) 13'10" (4200) 15'8" (4800) 17'9" (5400) 19'8" (6000) 21'7" (6600) 23'6" (7200) NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters. 2 3 (700) 4 7 (1400) 6 10 (2100) 9 2 (2800) 11 5 (3500) (4200) 16 (4900) 18 4 (5600) 20 7 (6300) (7000) 25 1 (7700) 27 4 (8400) 2 7 (800) 5 3 (1600) 7 10 (2400) 10 6 (3200) 13 1 (4000) 15 8 (4800) 18 4 (5600) (6400) 23 6 (7200) 26 1 (8000) 28 8 (8800) 31 5 (9600) A B 2 11 (900) 5 10 (1800) 8 10 (2700) 11 9 (3600) 14 9 (4500) 17 8 (5400) 20 7 (6300) 23 6 (7200) 26 5 (8100) 29 4 (9000) 32 5 (9900) 35 5 (10800) FRAME WIDTH OF A & B 3 3 (1000) 6 6 (2000) 9 10 (3000) 13 1 (4000) 16 4 (5000) 19 8 (6000) (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 36 1" (11000) 39 4" (12000) With 3 1/16" (78 mm) thick profile For units with 1 1/2" Triple Insulated Glass units and select units with Double Insulated Glass if no horizontal mullion is desired (for heights above 8'4") - FLOOR SUPPORTED ONLY Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width. For triple glazing with heights above 8 4 (2550 mm) a horizontal mullion is needed such that no glass pane is taller than 7'10" (2400 mm). A. For configurations with a swing panel hinged to a side jamb combined with a pair(s) of folding panels or for configurations with a pair(s) of folding panels only. Includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R, 2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R, 1L6R, 6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R B. For all configurations. The maximum size limits are based on the maximum weight of a panel that has a net glass thickness of 1/2 (12 mm) for larger net thicker glass, this maximum size limit chart will not apply. For configurations with only even number of panels stacking to each side, the minimum width of each panel is 2' 9 1/2" (850 mm). 17

18 RELATIONSHIP OF FRAME, PANEL AND GLASS DAYLIGHT OPENING SIZES WD66 Dimensions in millimeters unless noted. Calculation applies to the standard stiles and rails with panel thickness of 66 mm (2 5/8 ) and nominal widths of 78 mm (3 1/16 ). Glass dimensions of all panels in a unit are equal unless unequal panel widths are used. Nominal Panel Height (PH) is defined as Glass Daylight Opening Height (6 1/8 ). Nominal Panel Width (PW) is defined as Glass Daylight Opening Width (6 1/8 ). Panel Height is as seen from the inside on an inward opening unit and is as seen from the outside on an outward opening unit. Please note that with the overlap of the head jamb and the sill with the panel, the Clear Opening Height will not be the same as the Panel Height. See Cross-Section Details of both stiles of each panel to determine actual Panel Width. With astragals, overlapping, etc., the actual Panel Width not only varies with position of panel in a configuration, but the inside and outside surface widths of each stile may be different. For each configuration, the Frame Width (FW) is the sum of the nominal Panel Width (PW) x the number of panels + a number (N) which is the sum of the side jamb dimensions and dimensions of space between panels in excess of the nominal Panel Width as shown in the Cross-Section Details. This can be used as a guideline. Contact NanaWall for exact calculation for particular unit. Frame Height (FH) WA66/o top hung System Raised Sill : Frame Height = Panel Height (4 11/16 ) = Clear Opening Height (6 7/8 ) Low Profile Saddle Sill / Flush Sill: Frame Height = Panel Height (5 1/2 ) = Clear Opening Height (6 3/16 ) Alternate Flush Sill: Frame Height = Panel Height (5 1/8 ) = Clear Opening Height (5 ) Frame Height (FH) WA66/u Floor Supported System Raised Sill : Frame Height = Panel Height (4 1/16 ) = Clear Opening Height (6 3/16 ) Low Profile Saddle Sill / Flush Sill: Frame Height = Panel Height (4 3/4 ) = Clear Opening Height (5 1/2 ) Frame Widths for Different Configurations with Majority of Panels Folding to Right (and their Mirror Image Configurations with Majority of Panels Folding to Left). See Maximum Size Charts for size limits. Please note that widths for units with unhinged panels or angle turns will be different. Model 1R Frame Width = 1 x Panel Width = 1 x Panel Width + 5 3/8 Model 1L1R Frame Width = 2 x Panel Width = 2 x Panel Width + 5 7/8 Model 2R Frame Width = 2 x Panel Width = 2 x Panel Width + 7 Model 3R Frame Width = 3 x Panel Width = 3 x Panel Width + 6 3/8 Model 1L2R Frame Width = 3 x Panel Width = 3 x Panel Width + 8 3/4 Model 4R Frame Width = 4 x Panel Width = 4 x Panel Width + 8 1/16 Model 1L3R Frame Width = 4 x Panel Width = 4 x Panel Width + 6 7/8 Model 2L2R Frame Width = 4 x Panel Width = 4 x Panel Width /8 Model 5R Frame Width = 5 x Panel Width = 5 x Panel Width + 7 3/8 Model 2L3R, Model 1L4R Frame Width = 5 x Panel Width = 5 x Panel Width + 9 3/4 Model 3L3R, Model 1L5R Frame Width = 6 x Panel Width = 6 x Panel Width + 7 Model 2L4R Frame Width = 6 x Panel Width = 6 x Panel Width + 1 Model 6R Frame Width = 6 x Panel Width + 23 = 6 x Panel Width + 9 1/16 Model 1L6R, Model 2L5R, 3L4R Frame Width = 7 x Panel Width = 7 x Panel Width /16 Model 4L4R, Model 2L6R Frame Width = 8 x Panel Width = 8 x Panel Width /16 Model 3L5R Frame Width = 8 x Panel Width = 8 x Panel Width + 8 Model 4L5R, Model 3L6R Frame Width = 9 x Panel Width = 9 x Panel Width /16 Model 5L5R Frame Width = 10 x Panel Width = 10 x Panel Width + 9 Model 4L6R Frame Width = 10 x Panel Width = 10 x Panel Width /16 Model 5L6R Frame Width = 11 x Panel Width = 11 x Panel Width /16 Model 6L6R Frame Width = 12 x Panel Width = 12 x Panel Width /2 18

19 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 1.0 Head Jamb WD66/o (top hung) Detail 22.0 Low Profile Saddle Sill WD66/o (top hung) (For resistance against wind driven rain, drain connections by others are necessary. Sill is not centered with other frame components.) FFH Frame Height Detail 25.0 Thermally Broken Flush Sill WD66/o (top hung) (No rating against wind driven rain) FFH FFH Detail 2.0 Raised Sill (higher weather performance sill) WD66/o (top hung) Detail 26.0 Alternate Flush Sill WD66/o (top hung) (No Rating against wind driven rain. Sill is not thermally broken) Note: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided for both the Low Profile Saddle Sill and Flush Sill. 19

20 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 12.0 Head Jamb WD66/u (floor supported) Detail 14.0 Flush Sill WD66/u (floor supported) (No rating against wind driven rain). FFH Frame Height Detail 42.0 Raised Sill (higher weather performance sill) WD66/u (floor supported) Detail 13.0 Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) 1/2 [12] FFH 20

21 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 3R.0 Panel hinged at left side jamb Detail 3.0 Panel hinged at right side jamb Detail 4.0 Swing panel with locking at left side jamb Detail 4R.0 Swing Panel with locking at right side jamb 21

22 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 5.0 Panel with running carriage set meeting left side jamb Detail 5R.0 Panel with running carriage set meeting right side jamb Detail 7C.0 and 7RC.0 Folding panels with running carriage set 22

23 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. 7.0 and 7R.0 Folding panels with locking handle for 7R.0 handle for 7.0 Detail 8.0 Two swing panels with locking. Left panel opening first Detail 8R.0 Two swing panels with locking. Right panel opening first 23

24 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 9.0 and 9R.0 Meeting of panels folding to opposite side (no swing panel). Running carriage sets on both panels Detail 10.0 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.0 Meeting of swing panel with locking on right and folding panel with running carriage set on left 24

25 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 1.1 Head Jamb WD66/o (top hung) FFH Frame Height Detail 22.1 Low Profile Saddle Sill WD66/o (top hung) (For resistance against wind driven rain, drain connections by others necessary. Sill is not centered with other frame components.) Detail 25.1 Thermally Broken Flush Sill WD66/o (top hung) (No rating against wind driven rain) Detail 26.1 Alternate Flush Sill WD66/o (top hung) (No rating against wind driven rain. Sill is not thermally broken.) FFH Detail 2.1 Raised Sill (higher weather performance sill) WD66/o (top hung) FFH Note: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided for both the Low Profile Saddle Sill and Flush Sill. 25

26 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 12.1 Head Jamb WD66/o (floor supported) Detail 14.1 Flush Sill WD66/u floor supported (No rating against wind driven rain.) FFH Frame Height Detail 42.1 Raised Sill (higher weather performance sill) WD66/u (floor supported) Detail 13.1 Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) 1/2 [12] FFH 26

27 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 3R.1 Panel hinged at left side jamb Detail 3.1 Panel hinged at right side jamb Detail 4.1 Swing panel with locking at left side jamb Detail 4R.1 Swing panel with locking at right side jamb 27

28 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 5.1 Panel with running carriage set meeting left side jamb Detail 5R.1 Panel with running carriage set meeting right side jamb Detail 7RC.1 and 7C.1 Folding panel with running carriage set 28

29 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 7.1 and 7R.1 Folding panels with locking handle for 7R.1 handle for 7.1 Detail 8.1 Two swing panels with locking. Left panel opening first. Detail 8R.1 Two swing panels with locking. Right panel opening first. 29

30 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" triple glazing. Detail 9.1 and 9R.1 Meeting of panels folding to opposite side (no swing panel) running carriages set on both panels Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.1 Meeting of swing panel with locking on right and folding panel with running carriage set on left 30

31 SUGGESTED TYPICAL INSTALLATION WD66 Head Jamb (top hung) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, flashing, waterproofing, sealant, trim and other details for specific surrounding conditions must be properly designed and provided by others. INSTALLATION CONSIDERATIONS The approximate weight of a panel with double-glazing is lbs/ft 2 (27-39 kg/m 2 ), and with triple glazing is 8 lbs/ft 2 (39 kg/m 2 ). The vertical structural deflection of the header should be the lesser of L/720 of the span and ¼ (6 mm) under full loads. Although for floor supported systems, there is no vertical load on the header from the panels, structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre- Installation Preparation and Installation Guidelines in the General Introduction. An owner s manual with installation instructions is available upon request. Rough Opening From Subfloor Frame Height Standard Raised Sill (top hung) (higher weather performance sill) It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4 (6 mm). If not, both the dead and live loads need to be considered. For the floor supported WD66u, please note that there is no vertical load on the header. Panel Hinged At Right Side Jamb 31