1 NOTICE TO BIDDERS TO: All Bidders FROM: Alvin Kumar : 20 th July 2017 DESIGNATION: Deputy Manager Project Proposed New Changing Room and Waoom Facility at Nasinu Campus LOCATION: LOCATION: FNU Nasinu Campus TENDER NO: FNU030/17 NTT NO. 1 Division of Capital projects & Infrastructure, Derrick Campus, Samabula. This NTT shall be read in conjunction with Tender No. FNU030/17 Proposed New Changing Room and Waoom Facility at Nasinu Campus All bidders are requested to Note the following during the bid submission. 1. Size of Septic Tank 5,600 liters as per H1.3 attached 2. Size of all external block wall mm concrete block wall as per A1.1 & A1.2 attached 3. All doors are timber. The contractor is to work with the window and door specification identified in the table, the note provide in A4.1 are general notes and may or may not be used in this project. 4. As per the drawings the lock type is specified for the Toilet and Shower doors are indicator bolts. 5. Contractor is to remove from scope and drawings all Hot water items & Hand drier and only allow for supply of cold water. 6. Contractor is to allow for only PVC piping works for supply of water and waste water removal. 7. Contractor is allow for railing as per detail provide in page A5.3 attached 8. Contractor to allow for obtaining NFA, OHS and completion certificate from Local authority. 9. Contractor is to allow for all water connections and Electricity connections from existing sources. 10. Contractor is to allow for Selected 600 x 600 ceramic wall tilesmm high on concrete block wall with 2tile trims 300 high from both sides as per A3.1& A3.2. All bidders are requested to sign off a copy and to Deputy Manager Project, Mr. Alvin Kumar on or via dmp@fnu.ac.fj to confirm receiving of NTT No. 01. Tenderer s Name: Registered Company / Stamp: Date

2 7.1 Price Summary Item Trade FJD (VIP) 1.0 Preliminary & General $ 2.0 Excavation $ 3.0 Concrete Works $ 4.0 Metalworks/ Structural Steel $ 5.0 Masonry $ 6.0 Solid Plasterwork $ 7.0 Carpentry $ 8.0 Roofing $ 9.0 Plumbing / Drainage $ 10.0 Sanitary Ware $ 11.0 Ceramic Tiling $ 12.0 Painting $ 13.0 Timber Doors, Door Frames & Door Hardware $ 14.0 Hand Rails $ 15.0 Electrical $ 16.0 Fire Hose Reel $ 17.0 Planter $ 17.0 Any Other $ Grand Total $ Note I. Contractor is responsible to clean and clear site, and restore to initial conditions. II. The drawings and specification shall be carried out to the letter and are intended to be cooperative, i.e. any work shown on the drawings and not mentioned in the specification or work or materials herein specified or described but not shown on the drawings will be executed by the Contractor as if specifically shown or mentioned by both. III. Contractor is to make to any damages caused by his employees.

3 X A confirm all dimensions on site prior to construction 2. Whole of exterior & interior to be painted as per MP instruction. 3. All floor tiles to be layed as per MP instructions Y A3.2 Y A3.2 new mm conc. blockwall plastered & painted as per MP instruction new mm conc. blockwall plastered & painted as per MP instruction CHANGING AREA HB MALE WASHROOM URINAL HB HB HB HB ACCESS WALKWAY HB DISABLE WASHROOM FEMALE WASHROOM CHANGING AREA ACCESS WALKWAY HB MALE WASHROOM Selected 600x600 Ceramic floor tiles (color to be chosen by client),contractor to install with correct adhesive. (Ardex X56) & grout. concrete floor with Steel trowel finish (20mm fall) 1390 DOWN RAMP PROPOSED FLOOR LAYOUT PLAN SCALE 1:50 X A3.1 PLANTERS BE PROVEN ON JOB THE CONTRACTOR. PROPOSED FLOOR LAYOUT PLAN A1.1

4 W1 W2 W2 W2 W2 W2 W2 W2 W2 W CHANGING AREA D D2 D2 D2 D D2 D2 D MALE WASHROOM URINAL FEMALE WASHROOM 3801 CHANGING AREA HB HB HB HB HB HB D DISABLE ACCESS WALKWAY 1350 HB WASHROOM ACCESS WALKWAY 2500 D DOWN RAMP RAMP PROPOSED FLOOR SETOUT PLAN SCALE 1:50 BE PROVEN ON JOB THE CONTRACTOR. PROPOSED FLOOR SETOUT PLAN A1.2

5 KEY NUMBER REFERENCE 1. Concrete blockwall plastered & painted from outside and tile from inside as per Architects instruction. 2. Concrete floor with selected tile finish refer floor plans 3. Concrete beam plastered & painted as per Architects instruction refer structural dwg. for size & reinforcement 4. SHS column painted as per instruction refer structural dwg. for size & reinforcement 5. 6mm ply board ceiling with "V" joint on 50 x 50mm timber 600 ctrs painted as per MP instruction 6. RPFL Superdek color bond roof cladding over 450 double sided sisalation install as per manufacturers instruction x 225 x 0.8mm Colorbond gutter 450 ctrs. 8. dia. pvc downpipe allow to bracket to max. 1m ctrs 9. Polythene dpc on 50mm sand blinding and well compacted hardcore fill 10. Steel Rafters refer structural drawing for size & fixing 11. Steel purlins refer structural drawing for size & fixing 12.Ex. x 25 eaves battern with 10mm gaps in between over aluminium fly screen to be painted as per instructions 13.Ex. 300 x 50mm fascia board 14. Toilet partition wall, refer enlarge drawing for details. 15.Door/window as per schedule. 16. Vanity bench, refer enlarge drawing for details. 17. mm dia. P.V.C terminal vent with selected cowl over. 18."Dektite" pipe flashing 19.Railing as per detail. 20.Selected 600 x 600 ceramic wall tiles mm high on concrete block wall with 2 tile trims 300 high from both sides. 21. BE PROVEN ON JOB THE CONTRACTOR. PROPOSED CROSSSECTION XX A3.1

6 Concrete blockwall plastered & painted from outside and tile from inside as per Architects instruction. 2. Concrete floor with selected tile finish refer floor plans 3. Concrete beam plastered & painted as per Architects instruction refer structural dwg. for size & reinforcement 4. SHS column painted as per instruction refer structural dwg. for size & reinforcement 5. 6mm ply board ceiling with "V" joint on 50 x 50mm timber 600 ctrs painted as per MP instruction 6. RPFL Superdek color bond roof cladding KEY NUMBER REFERENCE over 450 double sided sisalation install as per manufacturers instruction x 225 x 0.8mm Colorbond gutter 450 ctrs. 8. dia. pvc downpipe allow to bracket to max. 1m ctrs 9. Polythene dpc on 50mm sand blinding and well compacted hardcore fill 10. Steel Rafters refer structural drawing for size & fixing 11. Steel purlins refer structural drawing for size & fixing 12.Ex. x 25 eaves battern with 10mm gaps in between over aluminium fly screen to be painted as per Architects instructions 13.Ex. 300 x 50mm fascia board 14. Toilet partition wall, refer enlarge drawing for details. 15.Door/window as per schedule. 16. vanity bench, refer enlarge drawing for details. 17. mm dia. P.V.C terminal vent with selected cowl over. 18."Dektite" pipe flashing 19.Railing as per detail. 20.Selected 600 x 600 ceramic wall tiles mm high on concrete block wall with 2 tile trims 300 high from both sides. PROPOSED LONGITUDINAL SECTION YY SCALE 1:50 BE PROVEN ON JOB THE CONTRACTOR. PROPOSED LONGITUDINAL SECTION YY A3.2

7 40Ø top and xx6mm SHS 40Ø top and xx6mm SHS 40Ø top and 40Ø Post welded to top & and fish tail into rc every 0mm ctrs 20Ø Bars spaced at mm Ctrs welded to 40Ø top and 20Ø Bars spaced at mm Ctrs welded to 40Ø top and 40Ø top and RAILING ELEVATION SCALE 1:10 RAILING TYPICAL SECTION SCALE 1:10 BE PROVEN ON JOB THE CONTRACTOR. TYPICAL RAILINGS DETAIL A5.3

8 NOTES: 1. ALL DIMENSIONS IN MM 2. CONCRETE TO BE 20MPa GRADE 3. REINFORCEMENTS 665 MESH OR BOTH WAYS ALL AROUND 4. MM BLOCKWALL CRS FOR HORIZONTAL & VERTICAL BARS 3300 PLAN SCALE: 1: WATER LINE WATER LINE WATER LINE LONGITUDINAL SECTION SCALE: 1:20 CROSS SECTION SCALE: 1:20 BE PROVEN ON JOB THE CONTRACTOR. FIJI NATIONAL UNIVERSITY PROPOSED CHANGING ROOM & WASHROOM SEPTIC TANK DETAILS 07/07/2017 H1.3 R2