700 E. Johnson St. Madison, WI A0.1 MIXED USE BUILDING. 700 E. Johnson St. Madison, WI VICINTY MAP SCALE: NONE DRAWING INDEX GENERAL NOTES

Size: px
Start display at page:

Download "700 E. Johnson St. Madison, WI A0.1 MIXED USE BUILDING. 700 E. Johnson St. Madison, WI VICINTY MAP SCALE: NONE DRAWING INDEX GENERAL NOTES"

Transcription

1 Mixed Use Building VICINTY MAP SCALE: NONE MADISON, WI GENERAL NOTES. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STATE OF WISCONSIN BUILDING CODE LATEST EDITION. 2. CONTRACTOR(S) ARE RESPONSIBLE FOR VERIFICATION OF, AND COORDINATION WITH, ALL DIMENSIONS SHOWN ON THESE DRAWINGS RELATIVE TO EXISTING CONDITIONS PRIOR TO BEGINNING WORK. 3. CONTRACTOR SHALL REPORT IMMEDIATELY TO THE ARCHITECT ANY DIMENSION(S) OR DISCREPANCIES VERBALLY, A WRITTEN REPORT SHOULD PROMPTLY FOLLOW. CONTRACTOR SHALL CEASE WORK IN THE AFFECTED AREA UNTIL DIRECTED BY THE ARCHITECT. 4. THE CONTRACTOR SHALL PROVIDE ALL METHODS AND EQUIPMENT FOR PROTECTING THE BUILDING, ALL MATERIALS, AND PERSONNEL FROM FIRE OR OTHER DAMAGE PRIOR TO STARTING. THE CONTRACTOR SHALL SUBMIT THE APPROVED METHODS AND EQUIPMENT IN WRITING FOR THE OWNER AND ARCHITECT'S REVIEW PRIOR TO STARTING WORK. 5. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY AND HEALTH LAWS AND REGULATIONS. 6. THE CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, SHEATHING, REQUIRED FOR THE SAFETY AND PROPER EXECUTION OF THE WORK. 7. EXECUTION OF THE WORK WILL INVOLVE CONSIDERATION FOR ALLOWING THE OWNER TO CONTINUE THE OPERATION OF THE BUILDING AND THE BUSINESS IN THE FACILITY AND ADJACENT FACILITIES. PRIOR TO THE AWARD OF THE CONTRACT, THE CONSTRUCTION SCHEDULE PREPARED BY THE CONTRACTOR SHALL BE SUBMITTED TO THE ARCHITECT AND SHALL BE COORDINATED WITH THE FACILITIES DEPARTMENT. OWNER'S APPROVAL OF THE PROPOSED SCHEDULE SHALL SUPERCEDE THE CONTRACT PROVIDED THE OVERALL TIME IS NOT CHANGED. 8. THE CONTRACTOR SHALL REVIEW ALL EXISTING CONDITIONS TO DETERMINE ALL SERVICES (ELECTRICAL, MECHANICAL AND PLUMBING) AFFECTED BY THE REPAIR WORK. THE CONTRACTOR SHALL MAKE NECESSARY TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SERVICES TO ALL AREAS OF THE BUILDING DIRECTLY AND INDIRECTLY AFFECTED BY THE WORK. THE CONTRACTOR SHALL SUBMIT METHODS AND SCHEDULE OF CONNECTIONS TO THE OWNER FOR APPROVAL PRIOR TO BEGINNING WORK. 9. AS THE WORK PROGRESSES, THE CONTRACTOR SHALL PRODUCE "AS-BUILT" DRAWINGS FOR THE INSTALLATION OF ALL REPAIR ITEMS UNDER THE CONTRACT. THE ARCHITECT WILL PROVIDE THE GENERAL CONTRACTOR WITH A SET OF REPRODUCIBLE PLANS FOR THIS PURPOSE. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE AS-BUILT DRAWINGS ACCORDING TO THE JOB PROGRESS. EACH PAY REQUEST SUBMITTED BY THE CONTRACTOR SHALL BE ACCOMPANIED BY A COPY OF THE UPDATED AS-BUILT DRAWINGS. 0. THE CONTRACTOR SHALL CALL "DIGGER'S HOTLINE" AT , 48 HOURS (EXCLUDING WEEKENDS AND/OR HOLIDAYS) PRIOR TO DIGGING ANY EXCAVATION. "DIGGER'S HOTLINE" WILL CONTACT UTILITY COMPANIES TO LOCATE AND MARK THEIR UNDERGROUND FACILITIES. NO SUCH WORK SHALL COMMENCE PRIOR TO VERIFICATION THAT ALL UTILITIES HAVE RESPONDED.. PROTECT TREES, SHRUBS, LAWNS, AND OTHER FEATURES WITHIN PROJECT LIMITS. RESTORE DAMAGED FEATURES TO ORIGINAL CONDITION. LOCATION MAP SCALE: NONE LOCATION GENERAL A00.0 COVER SHEET, INDEX, GENERAL NOTES A00.02 CODE REVIEW PLANS SURVEY SITE DESIGN A0.0 A0.02 A0.03 L0.0 STRUCTURAL SITE DEMO PLAN SITE CONTEXT PLAN ARCHITECTURAL SITE PLAN LANDSCAPE PLAN DRAWING INDEX ARCHITECTURAL A02.00 LOWER LEVEL FLOOR PLAN A02.0 GROUND FLOOR PLAN A02.02 SECOND FLOOR PLAN A02.03 THIRD FLOOR PLAN A02.04 ROOF PLAN A03.0 EXTERIOR PERSPECTIVES A03.02 BUILDING ELEVATION A03.03 BUILDING ELEVATION A03.04 BUILDING ELEVATION A03.05 BUILDING ELEVATION A04.0 BUILDING SECTIONS A05.0 WALL SECTIONS A05.02 WALL SECTIONS A05.2 EXTERIOR ENCLOSURE & ROOF DETAILS A05.22 EXTERIOR ENCLOSURE & ROOF DETAILS A05.23 EXTERIOR ENCLOSURE & ROOF DETAILS A06.0 ENLARGED PLANS A06.02 ENLARGED PLANS A07.0 PARTITION TYPES & DETAILS A08.0 DOOR SCHEDULE A08.02 DOOR & FRAME TYPES A08.03 DOOR DETAILS A08.2 WINDOW TYPES A08.23 WINDOW DETAILS A09.0 INTERIOR ELEVATIONS, TOILET ROOMS A09.02 INTERIOR ELEVATIONS, KITCHEN A0.00 LOWER LEVEL M.E.P. PLAN A0.0 GROUND FLOOR M.E.P. PLAN A0.02 SECOND FLOOR M.E.P. PLAN A0.03 THIRD FLOOR M.E.P. PLAN TITLE SHEET, INDEX, GENERAL NOTES A.0 VERTICAL CIRCULATION A.02 VERTICAL CIRCULATION A.03 VERTICAL CIRCULATION A0.

2 Zoning Data: 707/709 & 7/73 East Johnson Street June 5,206 NMX Requirements Provided Notes Minimum Front Yard Setback Maximum Front Yard Setback Side Yard Setback see note (a) 5 feet (adjacent residential bldgs. 5 feet) 25 feet max. 5 feet (see note (a)) see note (a) 0 feet (north side) (adjacent residential bldgs. 6 feet) 0.25 feet (south side) Rear Yard Setback 20 feet feet Maximum Lot Coverage 75% (max.) = 7, % building footprint Minimum Height n/a n/a Maximum Height (3) stories / 40 feet (3) stories = 36 feet Step Backs Usable Open Space (resid. only) Bike Parking Car Parking Ht. Transistion in Residential Districts conditional use request *There is room to shift building, if necessary to meet 25' max at required side & rear yrd set backs * Step Back requirements on east sideyard. 60 s.f. per bedroom 3,360 ground level s.f. per > per bedroom 0 /du (2br du) + /2 / (+2br) = = 2 (25) covered stalls 3 (2'x6') stalls Guest = /0 du = 3 (6) outside General Retail /400sf = ,078 sf / 400 = 5 parking stalls final count depence on final submitted use Restaurant 5% of capac. = % of 65 (estm.) = 0 parking stalls use 28I 4 to adjust/reduce count requirements Lot Area (s.f.) n/a acres Lot Width n/a 87 feet

3 SITE DEMO PLAN PLAN TRUE A. SCALE: " = 0'-0" SITE DEMO PLAN A.

4 INSITE CONSULTING ARCHITECTS Exterior - Front Exterior - Front & Side Exterior - Front & Side Exterior - Close Up - Front Porch Interior - Boiler Interior - Basement Wall Interior - Basement Wall Interior - Basement Floor Interior - Window 308 Blair Street - Apartments 308 Blair Street A.2 707/709 East Johnson Street House - Photos of Existing Conditions ICA NO. RPG 6-00 LAND USE APPLICATION 6/5/6

5 INSITE CONSULTING ARCHITECTS Exterior - South Exterior - East Exterior - West Exterior - Close Up - Front Porch Exterior - Close Up - Back Porch Interior - Basement Interior - st Floor Living Room Interior - st Floor Bedroom Interior - 2nd Floor Living Room Interior - 2nd Floor Bedroom 7 Johnson Street - House Move 207 North Blount Street A.2 7/73 East Johnson Street House - Photos of Existing Conditions ICA NO. RPG CITY SUBMITTAL 6/5/6 A.2

6 SITE CONTEXT PLAN SITE CONTEXT PLAN PLAN TRUE A.3 A.3 SCALE: /6" = '-0"

7

8

9 Plant Images Plant Schedule InSite Consulting Architects F:\RLS\INSITE\Johnson Street Plant Images.jpg F:\RLS\INSITE\Johnson Plant List.jpg Landscape Points Schedule Plant Type Pts Qty Sub-Total Overstory Deciduous Trees Tall Evergreen Trees Ornamental Trees Deciduous Shrubs Evergreen Shrubs Ornamental Grasses Total Provided 60 Total Required (Developable Area 5,860 x 5 points/300 sf = 97.67) Say 98 SITE CONTEXT PLAN SCALE: /6" = '-0" PLAN TRUE

10 SHEET NAME LOWER LEVEL PLAN PLAN A2.0 A2.0 SCALE: /4" = '-0"

11 SHEET NAME A2. GROUND FLOOR PLAN SCALE: /4" = '-0" PLAN A2.

12 SHEET NAME SECOND FLOOR PLAN PLAN A2.2 A2.2 SCALE: /4" = '-0"

13 SHEET NAME THIRD FLOOR PLAN PLAN A2.3 A2.3 SCALE: /4" = '-0"

14 A2.4 ROOF PLAN SCALE: /8" = '-0" PLAN SHEET NAME A2.4

15 VIEW LOOKING EAST FROM BLOUNT & JOHNSON STREET VIEW LOOKING -EAST FROM BACK LOT SHEET NAME A3.0 VIEW LOOKING SOUTH ACROSS JOHNSON STREET

16 CORRUGATED METAL FIXED SHADE AWNINGS HORIZONTAL METAL WALL PANEL (SINGLE SKIN PANEL), ALUMINUM PREFINISHED THERMALLY BROKEN ALUMINUM WINDOWS WITH INSULATED LOW-E GLASS, PROJECT-OUT SASH, OPERABLE AWNING WINDOWS TOP & BOTTOM InSite Consulting Architects LIMESTONE CAP MASONRY 4" VENEER MASONRY ENTRY 9'-4" HIGH WITH METAL ADDRESS SIGN THERMALLY BROKEN ALUMINUM WINDOWS WITH INSULATED LOW-E GLASS, CAFE STYLE SASH LIMESTONE WATER TABLE, 4" VENEER A3. WEST (JOHNSON STREET) ELEVATION SCALE: 3/6" = '-0" POTENTIAL COMMERCIAL SIGN LOCATIONS MECHANICAL EQUIPMENT SCREEN CORRUGATED METAL FIXED SHADE AWNINGS HORIZONTAL METAL WALL PANEL (SINGLE SKIN PANEL), ALUMINUM PREFINISHED CORRUGATED METAL PANELS, 2'-6" WIDE X 2'-0" L TRIMMED SEGMENTS MASONRY 4" VENEER ELEVATIONS LIMESTONE ACCENT BAND 2 SOUTH ELEVATION A3. A3. SCALE: 3/6" = '-0"

17 MECHANICAL EQUIPMENT SCREEN CORRUGATED METAL FIXED SHADE AWNINGS HORIZONTAL METAL WALL PANEL (SINGLE SKIN PANEL), ALUMINUM PREFINISHED THERMALLY BROKEN ALUMINUM WINDOWS WITH INSULATED LOW-E GLASS, PROJECT-OUT SASH InSite Consulting Architects VERTICAL METAL WALL PANEL (SINGLE SKIN PANEL), CORRUGATED ALUMINUM PREFINISHED MASONRY 4" VENEER LIMESTONE ACCENT BAND A3.2 EAST ELEVATION SCALE: 3/6" = '-0" MECHANICAL EQUIPMENT SCREEN CORRUGATED METAL FIXED SHADE AWNINGS HORIZONTAL METAL WALL PANEL (SINGLE SKIN PANEL), ALUMINUM PREFINISHED CORRUGATED METAL PANELS, 2'-6" WIDE X 2'-0" L TRIMMED SEGMENTS MASONRY 4" VENEER ELEVATIONS LIMESTONE WATER TABLE, 4" VENEER 2 A3.2 ELEVATION SCALE: 3/6" = '-0" A3.2

18 A3.3 SECTION SCALE: /4" = '-0" SECTION A3.3

19 ARCHITECTURAL SITE PLAN A.4

20 Zoning Data: 707/709 & 7/73 East Johnson Street June 5,206 NMX Requirements Provided Notes Minimum Front Yard Setback Maximum Front Yard Setback Side Yard Setback see note (a) 5 feet (adjacent residential bldgs. 5 feet) 25 feet max. 5 feet (see note (a)) see note (a) 0 feet (north side) (adjacent residential bldgs. 6 feet) 0.25 feet (south side) Rear Yard Setback 20 feet feet Maximum Lot Coverage 75% (max.) = 7, % building footprint Minimum Height n/a n/a Maximum Height (3) stories / 40 feet (3) stories = 36 feet Step Backs Usable Open Space (resid. only) Bike Parking Car Parking Ht. Transistion in Residential Districts conditional use request *There is room to shift building, if necessary to meet 25' max at required side & rear yrd set backs * Step Back requirements on east sideyard. 60 s.f. per bedroom 3,360 ground level s.f. per > per bedroom 0 /du (2br du) + /2 / (+2br) = = 2 (25) covered stalls 3 (2'x6') stalls Guest = /0 du = 3 (6) outside General Retail /400sf = ,078 sf / 400 = 5 parking stalls final count depence on final submitted use Restaurant 5% of capac. = % of 65 (estm.) = 0 parking stalls use 28I 4 to adjust/reduce count requirements Lot Area (s.f.) n/a acres Lot Width n/a 87 feet

21