Size: px
Start display at page:

Download "Concrete Water Tanks - 16,400 to 160,000 lt"

Transcription

1 Concrete Water Tanks - 16,400 to 160,000 lt Builders Catalogue ABN QBSA

2 Concrete Water Storage Tanks With over 36 years local experience, North Coast Tanks has evolved as leaders and innovators for durable and versatile water storage solutions. We construct all our tanks onsite. Concrete is sprayed onto form-work and finished off smooth producing a seamless construction. Every size tank is engineer-designed and steel re-inforced throughout, ensuring the structural integrity of your investment. Our standard range of tanks offers eleven sizes from 16,400 litres to 160,000 litres. Tanks can be constructed above, in or below ground, and can be engineered to specific load ratings as trafficable or as part of a building foundation or structure. As leaders in onsite concrete water tank construction, we pride ourselves on innovation, value, service, safety and of course quality. North Coast Tanks Pty Ltd is: BSA licensed (Lic.# QBSA ) and fully insured Fully compliant in WH&S Confined space qualified Approved commercial contractors performing to a Work Method Statement. DESIGN FEATURES High Strength Re-inforced Sprayed Concrete Built on site, for your site Able to access a wider variety of sites No concrete slab required Multifunctional, engineer-designed to suit a variety of load-bearing situations including: Pergola & outdoor entertainment areas Carports & under driveways Retaining wall Clothes hoist area Stormwater harvesting Above ground, in ground or completely buried Lockable aluminium hatch fitted as standard. 7 Year Warranty Will not burn or melt in bush-fire Keeps water cool preventing bacteria growth BUSHFIRE FIGHTING TANKS The Rural Fire Brigade and local Councils commonly specify 1 or more 10,000 gallon tanks for fire-fighting use where no reticulated water is available. We have a kit available to make your tank meet bushfire-fighting requirements. The kit includes: 1 x 50mm gate valve fitted with a 50mm Female Camlock Coupling Additional fittings to suit your sprinkler system Onga Blazemaster pump (Honda engine) STANDARD SIZES Capacity (litres) Capacity (gallons) Diameter (mm) Height (mm) Excavation (min) m x 5.2m m x 5.2m m x 5.4m m x 6.0m m x 7.1m m x 7.5m m x 7.9m m x 8.3m m x 9.2m m x 10.0m m x 11.5m 1 North Coast Tanks 2014

3 Tank Designs STANDARD TANK In ground to maximum depth of 2.3m For non-traffic areas Lockable aluminium access hatch fitted as standard Suits light load, eg. clothes hoist (not supplied) Suitable as retaining wall Can be covered with garden-mulch (but not soil) LIGHT LOAD BEARING TANK (4kPa) Rated for foot-traffic. Suitable as base for light construction, eg, pergola, garden shed, court-yard, etc Can be covered with up to 300mm of fill. In ground to maximum depth of 2.3m Suitable as retaining wall MEDIUM LOAD BEARING TANK (5kPa) In ground to maximum depth of 2.3m For light vehicle load areas Suitable as base for carport or driveway May have slab constructed over top Suitable as retaining wall STANDARD INCLUSIONS UNDERGROUND TANK Can be buried to a variety of depths in both trafficable and nontrafficable areas Purpose built: eg. great for stormwater harvesting Specifications depend on the individual site conditions & customer requirements. May have slab constructed over top * We also custom build tanks engineered to your specific load situation Above ground tanks: One 32mm Brass outlet socket One 32mm Brass hex nipple One 32mm Brass gate valve One 400mm or 500mm mosquito proof inlet stainer Two 100mm pvc overflow sockets with a 100mm mosquito proof screen. Lockable* childproof aluminium access hatch In ground tanks: One 32mm brass outlet socket One 32mm suction line PVC Pressure One 32mm Philmac Footvalve Two 100mm pvc overflow sockets with a 100mm mosquito proof screen. Lockable* childproof aluminium access hatch We offer a full range of fittings and fixtures to meet any requirement. Because the tanks are built onsite, sitespecific lay outs are individually catered for which makes plumbing hassle free. *Padlock not included North Coast Tanks

4 Site Requirements & Construction Details SITE Level Pad Out of level, wet, rocky or unstable bases are unsuitable. Construction must be on natural ground - no fill. Where required, North Coast Tanks can pour footings down to natural ground level at additional cost. Excavations Dirt piles 2m clear of edge steps Level base Benched or battered In-ground tanks; maximum excavation depth is 2.3m. Excavations require a minimum working space of 700mm on each and every side. Minimum excavation dimensions are listed with standard tank sizes on page 2. North Coast Tanks can arrange excavation through a licenced operator approximately 2 days before the due job date. For the tank base, a 50mm deep layer of 10mm or 20mm drainage gravel needs to be spread level prior to construction. Clear access side An ideal tank site, ready for gravel base. ACCESS Concrete pump and trucks need to be within approximately 20m of the tank site. Please enquire if the job will require pumping over further distances. Excavation needs to be left clear on one side for both work vehicles and staff to access with forms, tools and equipment. Tank construction is usually best done once the house slab is down and before other construction work on the site is commenced, depending on the size of the block and type of tank. CONSTRUCTION SCHEDULE Average lead time is around 2 to 4 weeks, however we regularly reserve vacant days for builders. Construction time is generally two days. The tank can be filled to a maximum one-third capacity immediately, and then filled to full capacity after a further 12 days. 3 North Coast Tanks 2014

5 Concrete Tank Fittings & Fixtures SEE PAGE 2 FOR STANDARD INCLUSIONS BRASS THREADED OUTLET SOCKETS INLET & OVERFLOW PVC SOCKETS INLET STRAINERS 11/4 X4 1 1/4 X 7 1 ½ X 4 2 X4 3 X7 32MM X 100MM 32MM X 175MM 40MM X 100MM 50MM X 100MM 75MM X 175MM 100MM 150MM 225MM 375MM *Fitted with Mosquito proof Stainless gauze caps as per Queensland Health Standards. NOTE: ALL SOCKETS ARE CAST IN THE WALL WITH WATERSTOP 300mm 400mm 500mm *Mosquito proof Stainless steel mesh as per Queensland Health Standards. OUTLETS: Above Ground To meet requirements; Gate Valves, Ball Valves & Taps available in 32mm,40mm, 50mm & 75mm sizes OUTLETS: In Ground Foot valves are available in 32mm,40mm, 50mm & 75mm sizes. Fitted with a suction line and barrel union to suit. ACCESS HATCH All tanks are fitted standard with an Aluminium Chequer-Plate hatch. Childproof lockable* hinged lid Light weight Available with riser for underground tanks Bushfire Tanks: 50mm Aluminium female Camlock coupling Rainwater Tank Accessories *Padlock not included INLET FILTERS & INSECT PROOFING SYSTEMS Rain-heads, filter pits and first-flush diverters will dramatically improve the quality of water and risk of mosquito bourne diseases. In Qld it is law that all the water passes through screening before the tank entry point. FOR INGROUND CONCRETE TANKS RAINHEADS Filters leaves and debris at the downpipe. Standard type or angled leaf deflector types. All with mosquito-proof secondary screens. 80, 90 & 100mm FILTER PITS Work well on a sloping block Handle large volumes of water Easier to clean than rain heads Outlet must be above tank inlet. Optional junk basket sits above mosquito screen Photo: Rainharvesting Pty Ltd Eliminates the need for inlet strainer on top of the tank. Improves child safety 700mm x 700mm x 660mm 560mm x 560mm x 510mm FILTER BAGS Synthetic filter bag attaches under 300mm and 400mm inlet strainer and filters particles down to 20 microns. Requires periodic emptying and washing. 12 month warranty Diagram: Rainharvesting Pty Ltd North Coast Tanks

6 Rainwater Tank Accessories...continued PUMPS & ACCESSORIES PUMPS FILTERS PACKAGE DEALS As distributors for Pentair Water, we supply Onga products including pumps, filters and fittings. The most popular pumps shown here for domestic use are the jet-assisted JSP Series and the multistage automatic pressure SMHP & SSHP Series. These pumps are simple, reliable and offer outstanding performance and pressure control. In cases where a household relies on a tank for the main water supply, we recommend including a high quality filtration system. Onga filtration cartridge elements will effectively reduce the presence of Cyst (Giardia, Cryptosporidium), rust, sediment & sand. We have package deals and offers available, including supply and installation of precast concrete tanks and pumps. Call now for more info. Pre-cast Concrete tank & pump packages. See prices next page... Precast Concrete Tanks Which type of concrete tank is better? Onsite or Precast? Each type of tank has specific applications. Please see below for benefits of each, or feel free to call us to discuss your water storage solutions. Whichever type of tank is needed or preferred for your project, North Coast Tanks expertise guarantees the best installation with the minimum hassle. With nearly 4 decades invested in building our reputation as one of Australia s best onsite tank builders, we supply and install precast concrete tanks from manufacturers with a similar commitment to quality. ONSITE TANKS vs. PRE-CAST TANKS LARGER SIZES Standard sizes from 16,400 to 160,000 litres. Larger tank = Lower cost per litre of capacity. Larger site area required. Usable roof area. eg. Pergola, BBQ area, etc. Fewer tanks for total required capacity. ONSITE CONSTRUCTION Licensed construction. Fully BSA insured. Engineered to project requirements. Fewer access restrictions. No crane required. Construction time generally 1 tank per day. (depending on size) 7 year guarantee FINISHING Additional day required for finishing. Able to 1/3 filled immediately. 100% after 12 days. SMALLER SIZES Standard sizes from 3,700 to 23,000 litres. Smaller tank = Higher cost per litre of capacity. Suitable for smaller site areas (with access). Small roof area. Multiple tanks for total required capacity. OFFSITE MANUFACTURE Building component. Insurance on install only. Engineered to factory specifications only. Crane access required. Installation time. Multiple tanks per day. FINISHING No additional finishing required. Able to be 50% filled immediately. 5 North Coast Tanks 2014

7 North Coast Tanks Pty Ltd. QBSA Postal Address: P.O.Box 571 Palmwoods Q.4555 Ph Fax