Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1

Size: px
Start display at page:

Download "Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1"

Transcription

1 PROFIBUS DP ES PROFIBUS DP ES PROFIBUS DP ES ES cable for permanent installation ES cable for permanent installation ES sturdy cable for chemical (easy to strip) (easy to strip, FRNC) and mechanical stress (easy to strip) UL listed: CM inner jacket: FRNC Thermoplastic Copolymer (FRNC) violet Thermoplastic Polyurethane (TPU) violet Flame retardant acc. to IEC and UL 1685 (CSA FT 4), limited oil resistant, mineral oil and fat resistant, UL-File E Vol. 1 Sec. 16 Page 7, UL 1685 (vertical tray), oil resistant acc. to UL 2556 Sec UL-File E Vol. 1 Sec. 6 Page 7, UL-File E Vol. 1 Sec. 11 Page 1 UL-File E Vol. 1 Sec. 8 Page 1 02YSY(ST)CY 1x2x0.64/ VI KF40 FR 02YSH(ST)CH 1x2x0.64/ VI KF25 FRNC 02YSY(ST)C11Y 1x2x0.64/ VI KF40 FR L45467-G16-C185 L45467-G16-C286 L45467-G16-C118 LEONI 17

2 PROFIBUS DP ES PROFIBUS DP ES PROFIBUS DP ES ES cable for food industry (easy to strip) ES cable for direct burial (easy to strip) ES trailing cable (easy to strip) (0.006 in), Ø 0.65 mm (0.026 in), Polyethylene (PE) black Inner jacket: Thermoplastic Polyurethane (TPU) petrol outer jacket: Polyethylene (PE) black Ø 10.8 ± 0.5 mm (0.425 ± in) Cold bending resistant acc. to IEC , Cold bending resistant acc. to IEC , limited mineral oil and fat resistant limited mineral oil and fat resistant mineral oil and fat resistant, oil resistant acc. to UL 2556 Sec UL-File E Vol. 1 Sec. 8 Page 1, oil resistant acc. to UL 13 Sec. 40 (60 C) also available as a CMG version 02YSY(ST)C2Y 1x2x0.64/ KF40 BK 02YSY(ST)CY2Y 1x2x0.64/ KF40 BK 02YY(ST)C11Y 1x2x0.65/ LI KF40 FR petrol L45467-G16-C246 L45467-G16-C236 L45467-G16-C98 18 LEONI

3 PROFIBUS DP ES PROFIBUS DP PROFIBUS DP ES cable for flexible installation (easy to strip) Marine cable for flexible installation Cable for permanent installation 1x2x22AWG7 [ a ] SHF 1 UL listed: CMG and PLTC [ b ] SHF 2 [ a ] Stranded bare copper wire Ø 0.76 mm (0.006 in), Ø 0.67 mm (0.026 in), (0.030 in), insulation of foamed Polythylene (PE) with skin Ø 2.56 mm (0.101 in) [ b ] Stranded bare copper wire Ø 0.75 mm (0.030 in), insulation of foamed Polythylene (PE) with skin plastic tape over- 2 wires twisted to a pair with fillers in gaps lapped, inner jacket: FRNC applied longitudi- nally, of tinned copper wires Ø 0.15 mm Thermoplastic copolymer (FRNC) violet Flame retardant acc. to IEC [ a ] Flame retardant acc. to IEC and Flame retardant acc. to IEC and UL 1685 (CSA FT 4), (CAT. A/F), halogen free acc. to and UL 1685 (CSA FT 4), cold bending resistant acc. to IEC DIN VDE , [ b ] Flame retardant acc. to IEC and (CAT. A/F), halogen free acc. to limited oil and fat resistant, UL-File E Vol. 1 Sec. 16 Page 7, IEC 60754, oil resistant acc. to EN UL-File E Vol. 1 Sec. 16 Page 7, UL-File E Vol. 1 Sec. 6 Page 7, (24 hours/100 C), sunlight resistant UL-File E Vol. 1 Sec. 6 Page 7, Maritime and offshore approvals: Lloyds Register of Shipping, Bureau Veritas, ABS Europe, Det Norske Veritas, Germanischer Lloyd 02YSY(ST)CY 1x2x0.65/ LI VI [ a ] 02YSH(ST)CH 1x2x0.75/ LI VI FRNC 02YS(ST)CY 1x2x0.64/ VI KF40 FR [ b ] 02YSH(ST)CHX 1x2x0.75/ LI VI FRNC L45467-G16-C375 [ a ] L45467-G17-C46 (SHF1) L45467-G16-C145 [ b ] L45467-G17-C56 (SHF2) LEONI 19

4 PROFIBUS DP PROFIBUS DP PROFIBUS DP Cable for permanent installation (FRNC) Cable for permanent installation (FRNC) High temperature cable (FE90: insulation integrity 90 minutes) for permanent installation insulation of foamed FEP flame protection foil overlapped Ø 2.75 mm (0.108 in) 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps, flame protection foil overlapped Thermoplastic Copolymer (FRNC) violet Thermoplastic Copolymer (FRNC) grey Perfluorethylenepropylene (FEP) violet Ø 8.8 ± 0.4 mm (0.346 ± in) Ø 7.2 ± 0.25 mm (0.283 ± in) Flame retardant acc. to IEC , Insulation effect under fire Oil resistant, conditions acc. to IEC 60331, sunlight resistant acc. to UL 2556 Sec halogen free high temperature range (up to 180 C) 02Y(ST)CH 1x2x0.64/ VI FRNC KF25 02YS(ST)CH 1X2X0.64/ Y(ST)C6Y 1x2x0.64/ VI GR FRNC FE 90 L45467-G16-C206 L45467-G16-C266 L45467-G16-N17 20 LEONI

5 PROFIBUS DP PROFIBUS DP PROFIBUS DP Cable with rodent protection EMC cable for permanent installation (electro- Trailing Cable (FRNC) for permanent installation magnetic compatibility) or for direct burial (0.006 in), Ø 0.64 mm (0.025 in), 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps, tinned copper drain wire 2 wires twisted to a pair with fillers in gaps of tinned copper wires Ø 0.15 mm (0.06 in), copper tape longitudinal welded violet, Ø 8.0 ± 0.4 mm and spiral corrugated (0.315 ± in), armouring: 2 layers galvanised steel tape, intercalated tapes Polyethylene (PE) black Thermoplastic Polyurethane (TPU) petrol Ø 10.8 ± 0.5 mm (0.425 ± in) Ø 11.1 ± 0.3 mm (0.437 ± in) Ø 8.5 ± 0.4 mm (0.335 ± in) Sunlight resistant, limited mineral oil and fat resistant sunlight resistant oil resistant acc. to UL 13 Sec. 40 (60 C), UL-File E Vol. 1 Sec. 8 Page 1 02YS(ST)CYB2Y 1x2x0.64/ (2B0.1VZK) 02YS(ST)WKY 1x2x0.64/ VI KF40 FR 02YS(ST)C11Y 1X2X0.64/ LI FRNC petrol L45467-G16-C276 L45467-G16-C355 L45467-G16-C88 LEONI 21

6 PROFIBUS DP PROFIBUS DP PROFIBUS DP-Desina Festoon cable Torsional stress cable Hybrid cable for trailing application 9 1x2x24AWG x1.5 mm² (0.059 square in) Stranded bare copper wire 19x0.16 mm Wire LIY 1.5/2.4 (0.006 in), Ø 0.65 mm (0.026 in), (0.006 in), Ø 0.8 mm (0.031 in), Stranded bare copper wire 84x0.15 mm (0.006 in), Ø 1.6 mm (0.063 in), Ø 2.56 mm (0.101 in) Ø 2.56 mm (0.101 in) insulation of PVC Ø 2.4 mm (0.094 in) Wire 02Y 0.65/2.56 LI (0.006 in), Ø 0.65 mm (0.256 in), Screened pair 02Y(ST)C alulaminate foil overlapped, of tinned copper wires Ø 0.15 mm (0.006 in) 2 wires twisted to a pair with fillers in gaps 2 wires twisted to a pair with fillers in gaps 1 screened pair, 4 wires 2 layers of plastic tape conductive, of tinned copper wires Ø 0.1 mm (0.004 in) Polyvinylchloride (PVC) petrol Thermoplastic Polyuretahne (TPU) violet Ø 8.0 ± 0.3 mm (0.315 ± in) Ø 11.0 ± 0.3 mm (0.433 ± in) Flame retardant acc. to UL 1685 (CSA FT4), Flame retardant acc. to UL 1685 (CSA FT4), oil resistant acc. to UL 13 Sec. 40 (60 C), oil resistant acc. to UL 13 Sec. 40 (60 C) oil resistant acc. to UL 13 Sec. 40 (60 C), UL-File E Vol. 1 Sec. 16 Page 6, and UL 2556 Sec , UL-File E Vol. 1 Sec. 16 Page 1, UL-File E Vol. 1 Sec. 6 Page 6, UL-File E Vol. 1 Sec. 8 Page 1 UL-File E Vol. 1 Sec. 6 Page 1, 02YS(ST)CY 1x2x0.65/ LI petrol FR 02YS(ST)C11Y 1x2x0.8/ LI FR VI 02Y(ST)C 1x2x0.65/ LI LIY-ZY 4x1x1.5 VI L45467-G16-C255 L45467-G18-C18 L45467-G116-W45 22 LEONI

7 PROFIBUS DP-Desina PROFIBUS DP-ET 200X PROFIBUS DP-ET 200C Hybrid cable for trailing application (FRNC) Hybrid cable for trailing application (FRNC) Hybrid cable for permanent and flexible instal- 1x2x24AWG x1.5 mm² (0.059 square in) 9 + 3x0.75 mm 2 (0.030 square in) lation, 9 + 3x0.75 mm 2 (0.030 UL recognised: AWM UL recognised: AWM square in), UL recognised: AWM Wire LIH 1.5/2.4 Wire LIY 0.75/1.7 Wire LIY 0.75/1.7 Stranded bare copper wire 84x0.15 mm Stranded bare copper wire 24x0.2 mm Stranded bare copper wire 24x0.2 mm (0.006 in), Ø 1.55 mm (0.061 in), (0.008 in), Ø 1.15 mm (0.045 in), (0.008 in), Ø 1.15 mm (0.045 in), insulation of FRNC Ø 2.4 mm (0.094 in) insulation of PVC Ø 1.7 mm (0.067 in) insulation of PVC Ø 1.7 mm (0.067 in) Wire 02Y 0.65/2.56 LI Wire 02Y 0.65/2.56 LI Wire 02YS 0.25/2.56 LI Stranded bare copper wire 19x0.13 mm Stranded bare copper wire 19x0.13 mm (0.006 in), Ø 0.65 mm (0.256 in), (0.005 in), Ø 0.65 mm (0.256 in), (0.005 in), Ø 0.65 mm (0.256 in), Screened pair 02Y(ST)C Screened pair 02Y(ST)C Pair 02YS alulaminate foil over- alulaminate foil over- 2 wires twisted to a pair lapped, of tinned copper wires lapped, of tinned copper wires Ø 0.15 mm (0.006 in) Ø 0.15 mm (0.006 in) 1 screened pair, 1 pair twisted, 1 pair twisted, 4 wires 3 wires 3 wires braiding of tinned copper wires Ø 0.15 mm (0.006 in) Thermoplastic Polyurethane (TPU) violet Thermoplastic Polyurethane (TPU) petrol, Polyvinylchloride (PVC) petrol, Ø 11.0 ± 0.3 mm (0.433 ± in) Ø 9.5 ± 0.5 mm (0.374 ± in),, also available with PVC jacket for also available with TPU jacket permanent and flexible installation for trailing applications UL-Style 2464 oil resistant acc. to UL 758 Sec. 15 (60 C), oil resistant acc. to UL 758 Sec. 15 (60 C), UL-Style UL-Style Y(ST)C 1x2x0.65/ LI 02Y(ST)C 1x2x0.65/ LI 02Y 1x2x0.65/ LI LIH-Z 11Y 4x1x1.5 VI FRNC LIY-J 11Y 3x1x0.75 petrol LIY-J CY 3x1x0.75 petrol L45467-G116-W58 L45467-G116-W38 L45551-W59-W15 LEONI 23