EXPLORER Water Heater Heat Pump presentation. 6th February 2012

Size: px
Start display at page:

Download "EXPLORER Water Heater Heat Pump presentation. 6th February 2012"

Transcription

1 EXPLORER Water Heater Heat Pump presentation 6th February

2 1. New Heat-pump Water-heater presentation 1.1 Heat-Pump WH : Different possibilities 1.2 Our solution for each installation choice 1.3 New model description 1.4 Our range Mono block 1.5 Ariston comparison 1.6 Noise level comparison 1.7 Price positioning 1.8 Competitors positioning 1.9 Heat-Pump / other solutions comparison 2. Explorer presentation 3. Planning 2

3 1.1 Heat-Pump WH : Different possibilities Extracted air 2 in 1 : Air control / Water-Heater Silent working Split Compact Silent working Efficiency Ambient air Easy to install Half ducting Efficiency Complete ducting Efficiency Room T Efficiency Compact Room T 3

4 1.2 Our solution for each installation choice Extracted air Split version Aeraulix Odyssee split Capacity : 200 L COP (20 C EN255-3) : 3.4 Noise level (2m) : 36dB Heat time (15 to 51 C) : 10H30 Elec. Backup : 1800W Rust protection : ACI Flow max : 265m3/H Capacity COP (15 C EN255-3) : 3.8 Noise level (5m) : VM 200L FS 300 L : 34 db T range (air) : C Elec. Backup Rust protection : 1800W : ACI 4

5 1.2 Our solution for each installation choice Ambient air only ( stopped ) Ambient / ducting models Discovery 2 Odyssee 2 Capacity : 190 L COP (15 C EN255-3) : 3.5 Noise level (1m) : 48dB T range (air) : C Heat time (15 to 45 C) : 4H15 Elec. Backup : 2200W Rust protection : Mg External installation : YES Capacity : 270 L COP (15 C EN255-3) : 3.8 Noise level (2m) : <39dB T range (air) : C Heat time (15 to 50 C) : 6H50 Elec. Backup : 1800W Rust protection : ACI External installation : NO 5

6 1.3 New model description Ambient / ducting New models Explorer 200 / 200 coil Explorer 270 / 270 coil Capacity : 200 L COP (15 C EN255-3) : 3.7 Noise level (2m) : 37dB T range (air) : C Elec. Backup Tank protection External installation Coil (option) : 1800W : Mg : YES : 24 KW Possible to lay down horizontally on 1 side Capacity : 270 L COP (15 C EN255-3) : 3.8 Noise level (2m) : 37dB T range (air) : C Elec. Backup Tank protection External installation Coil (option) : 1800W : Mg : YES : 24 KW Possible to lay down horizontally on 1 side 6

7 1.4 Our range Monobloc COP 3.5 COP 3.7 COP 3.8 COP 3.8 7

8 1.5 Competitor comparison

9 1.6 Noise level comparison Accoustic comparaison ( through approved test institute) Tested in ambiant-air conditions (no ducting) Noise level comparaison (Noise probe situated at 1 meter front/center of the product) db(a) Average on the complete cycle Start of the cycle End of the cycle Minimum pick Maximum pick Explorer / Aeromax-Premium Odyssee / Aeromax Viessman (Tresco) Ariston Nuos 9

10 1.9 Heat-Pump / other solutions comparison For North-European countries, Heat-Pump WH should be compared with Direct electric WH : COP : 3,73 Average consumption / year : KW/Year (calculation for a familly 4 persons) Electric WH based on 150L, Heat-pump WH based on 200L Electricity cost ( /KW) Belgium (Wallonie) Belgium (Flandre) Swiss 0,19 0,19 0,18 Classic Electric WH Heat-Pump WH Classic Electric WH Heat-Pump WH Classic Electric WH Heat-Pump WH Product Price Subsidy 750,00 201,18 Annual consumption Payback time : (year) Yearly gain after payback : 3,3 4,8 5,

11 1.9 Heat-Pump / other solutions comparison For South-European countries, Heat-Pump WH should be compared with Solar installation : Biopack models : North of Spain, Italy, Portugal Rooftop models : South of Spain, Italy, Portugal Advantages for our new Heat Pump WH compared to Solar are : Same efficiency as solar with the coil (solar mode) Better efficiency than solar in Autumn, Winter, Springtime (due to Heatpump) Easier to install (ambient installation) 11

12 1. New Heat-pump Water-heater presentation 2. Explorer presentation 2.1 Design details 2.2 Technical data 2.3 Remote control 2.4 Working mode 2.5 Automatic mode 2.6 References 3. Planning 12

13 2. Explorer presentation 13

14 2.1 Design details Adjustable Air inlet/outlet Heat pump temperature range from +5 to +43 C Outside-proof coating Radio remote control Programmable (working period) 5 modes (Holiday, ECO, AUTO, BOOST, SOLAR) Statistics (consumption ) Error management / servicing High efficiency Heat pump : COP = 3.7 / 3.8 (at 15 C air) Direct heating element 1800W Enamel coating & Magnesium anode Coil 24KW (0.64 m²) Solar mode Boiler mode 14

15 2.1 Design details New Heat pump design : Lifetime Efficiency Silence Adjustable Air inlet / outlet Ø160mm Easy to install All component insulated silent working 15

16 2.1 Design details Phonic foam high efficiency Compressor Highly Hitachi 12.2 cc Pressure reduction valve DANFOSS Exchanger 4 rows 2 circuits Fan EBM Ø190 Radial model 2 speed Electronic regulation with radio receiver 2 x PPE shell 16

17 2.2 Technical data Technical specification Capacity Dimensions Net weight Tank capacity according to DIN 4753 Electric backup volume Rated water pressure Electrical connection Maximal total power consumed by the device Average power consumed by the heat pump Power consumed by electric heating Water temperature range by heat pump Heat pump temperature range of use Electrical temperature range of use ( C) Refrigerant fluid (L) (mm) (kg) (L) (L) (bars) ( V / Hz ) (W) (W) (W) ( C) ( C) ( C) R 134A (kg) * 676 * , V / 50 Hz to 62 C 5 to 43 C 0 to 43 C 1, * 676 * , V / 50 Hz to 62 C 5 to 43 C 0 to 43 C 1,25 Capacity Vacuum air flow (unsheated installation) Vacuum air flow (sheated installation) Lagging lenght Coefficient of performance at 15 C (*) (ambient) Coefficient of performance at 7 C (*) (ambient) Coefficient of performance at 7 C (**) (product lagged) Coefficient of performance at 15 C (**) (product lagged) Acoustic pressure at 1 m Noise level at 2m Heat pump heating time from 15 to 51 C at 7 C air (product lagged) Heat pump heating time from 15 to 51 C at 15 C air (ambient) Solar/Boiler coil power (coil version) (L) (m3/h) (m3/h) (m) ( dba) db(a) H H KW m² m + 2 bends 3,79 3,1 2,2 2, H22 4H , m + 2 bends 3,73 3,05 2,34 2, H52 7H ,64 Solar/Boiler coil surface (coil version) (*) In the conditions of EN 255-3, 15 to 51 C water (**) In the conditions of EN 16147, 15 to 51 C water 17

18 2.3 Remote control Radio remote control (long range emission) Running mode Dynamic view Boiler mode (coil models only) Mode selection Programming functions High contrast display (temperature, informations ) Solar mode (coil models only) Set-up / Maintenance mode Mode selection Information / statistics (consumption, running time ) 18

19 2.4 Working mode Eco : Heat pump only (except if set point is not possible to reach : Air T too low for instance) Set-point can be adjusted between 40 end 55 C Safe mode (45 C) if temperature is not possible to reach only with heat pump Auto : Heat pump + Boiler coil (if fitted) + Electric Set-point can be adjusted between 50 and 62 C 1st Heat-Pump, 2nd Boiler coil, 3rd Electric See diagram on next page Boost : All available energies Set-point = 62 C, when set temperature reached, WHHP returns to previously selected mode Solar : Solar coil + Electric External solar station controls the heat-up process by using coil and electric heating element if needed Holidays : Regulation at 7 C during the number of days set (1 to 99), automatic heat-up in previous mode. (return day 1 : anti-legionella program) 19

20 2.5 Automatic mode Automatic mode Temperature lower than setpoint? NO YES Heat pump working time > 7H and set point not reached? YES NO Heat-Pump regulation Boiler coil working time > 30 minutes and set point not reached? YES NO Temperature reached? NO Heat-Pump + Boiler coil regulation Heat-Pump + Boiler coil + Electric regulation YES NO Temperature reached? NO Temperature reached? YES YES Stop heating 20

21 2.6 References Atlantic references : References Designation Commercial Name CETHI 200L CETHI 200L SERPENTIN CETHI 270L CETHI 270L SERPENTIN Explorer 200L Explorer 200L Coil Explorer 270L Explorer 270L Coil 21

22 1. New Heat-pump Water-heater presentation 2. Explorer presentation 3. Planning 22

23 3. Planning Availability (ex-works France) End Aprilm End April 2012 : Explorer 200 & 270 without coil End December 2012 : Explorer 200 & 270 with coil 23