Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

Size: px
Start display at page:

Download "Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC"

Transcription

1 Analysis systems Analysis system for CO, Nox, O2, T Conditioned analysis system for the CO-NOx, O2, Temperature measure in flue gas methane boiler Composed of: Zirconia oxygen analyzer CO and NO NDIR infrared analyzer Flue gas temperature measure with K thermocouple Probe with heated filter Heated Line with front panel controller Converter NO2/NO Compressor gas cooler Condense monitor Flow-meter Direct calibration or from sampling probe Plc and alarms Card for communication with data acquisition Acquisition data DAS-DAC. Designed, realized and tested following CEI En of the 11/2001 Analysis systems for CO, O2, T multiplexing, OPC Conditioned analysis system for the measure of CO, O2, Temperature, in the flue gas of 3 biogas combustible motors. It composes of: Zirconia Oxygen analyzer. One CO and NO NDIR infrared analyzer Flue gas temperature measure with Tck Probes with heated filter Heated Line with front panel controller Compressor double channel gas cooler Heated 120 C with solenoid valve and hot filtering. Condense monitor and flow-meters Direct calibration or from sampling probe. Plc and alarms Card for communication with data acquisition Acquisition data DAS-DAC with OPC bridging. Designed, realized and tested following CEI En of the 11/ SEREGNO (MI) - Via Ripamonti, 58 tel Fax ferstrumenti@fer-strumenti.com

2 Analysis systems Analysis system for CO, O2, O2, T Ventilated analysis system for the CO measure, extractive and in situ Oxygen, flue gas temperature. Is composed of: Extractive zirconia oxygen analyzer In situ zirconia oxygen Analyzer. Double electrochemical cell CO analyzer. Flue gas temperature measure with K thermocouple Compressor gas cooler Condense monitor Flow-meter Direct calibration or from sampling probe Complete hard-wired system for analogical and digital signaling with 4-20 ma and clean contacts. Analysis system for CO, O2, T with panel printer Ventilated analysis system for the CO measure, extractive O2, flue gas temperature from wood boilers. It is composed of: Electrochemical cell oxygen analyzer Double electrochemical cell CO analyzer. Flue gas temperature measure with K thermocouple Compressor or Peltier gas cooler Condense discharger with peristaltic pump Condense monitor Flow-meter Plc of A/D conversion and averaging and serial printing to normal paper panel printer SEREGNO (MI) - Via Ripamonti, 58 tel Fax ferstrumenti@fer-strumenti.com

3 . Analyzers and systems for flue and combustible gas Home Products References Contacts Presentation Catalogues Services Laws and norms Continuous emissions monitoring Systems CEMS TECHNICAL REFERENCE Complete analysis systems can be projected, produced, commissioned end serviced. The systems are custom designed for meeting client needs and plant details. Communications from and to plant supervisor systems is done either with fully comprehensive hard wired connections or via LAN connections using *OPC standards. The equipments are housed in water proof enclosure with cooling and/or heating system that is completely assembled and tested in our workshop, ready for commissioning. The system is fully protected: all components whose irregular running could affect the safety of the measure or the system, are provided with alarms that stop the pump and light an alarm; these alarms along with the faults alarms of the analyzers are transmitted to the data acquisition on the remote PC. The systems can be projected to measure gases incoming from different stacks, up to 6, a PLC drives the scanning via S.S. solenoid valves. When the sample need to be maintained hot to ensure nothing could solve in the condense we use special solenoid valves 180 C resistant in INOX high temperature controlled boxes. *(OPC: OLE for Process Control. OPC is a technology based on OLE Microsoft standards (now ActiveX), COM (component object model) e DCOM (distributed component object model) in few words on several interfaces, properties and methods defined for plant control and industrial automation. For more information and details see COMPONENTS USED fine filter (1 micron) and condense detector sampling probes with heated silicon carbide filter flow meters with alarm heated sampling lines with temperature regulator, length up to 150m. solenoid (heated or not) valves for automatic calibration and stack scanning extractive Zirconia based Oxygen analyzer I R gas analyzer for CO-NOx-SO2-CH4-CO2. TOC Flame ionization analyser for total hydrocarbon measure Selectable Ion HCL and HF analyser NH3/NO high temperature converter for Ammonia measure compressor gas conditioner with continuous condense discharger. Heat exchanger in S.S., Teflon or glass. Digital reading of temperature and alarm. sampling pumps for corrosive gases Electrodynamics in situ dust analyser NO2/NO catalytic converter Electrochemical Cells for CO-O2-NO Samples Photo gallery 1) CO-O2 continuous monitoring on flue gas from oil plant 2) CH4 e O2 continuous monitoring on biogas with two point multiplexing

4 3) CO-NOx-O2-T continuous monitoring on flue gas from biogas fired engine multiplexing on 4 point (2 redundant system) 4) TOC continuous monitoring on regenerative combustion flue gas 5) CO-NOx-O2-T continuous monitoring on flue gas from 3 cogenerating machine 6) CO-NOx-SO2-O2-T-Dust-Flow continuous monitoring on flue gas from brick furnace 7) Double CO-NOx-O2 continuous monitoring on two flue gas form n.2 Turbogas.

5 8) CO-NOx-SO2-O2 continuous monitoring on flue gas from electronics waste melting furnace 9) CO-NOx-SO2-O2-TOC continuous monitoring on flue gas from liquid incinerating plant 10) CO-NOx-O2-T continuous monitoring on flue gas multiplexing on 4 wood furnace. 11) CO-NOx-SO2-O2-T continuous monitoring multiplexing on 4 flue gas from Biogas fired engines. 11) CO-O2-T modular, wall mounting with printer for semi hour and daily average reporting