SLZ-KF25VA2 SUZ-KA25VA6. Indoor unit Outdoor unit. Model A A + A A + + A B C D E B C D E 2,2 4, /2011

Size: px
Start display at page:

Download "SLZ-KF25VA2 SUZ-KA25VA6. Indoor unit Outdoor unit. Model A A + A A + + A B C D E B C D E 2,2 4, /2011"

Transcription

1 Model Indoor unit Outdoor unit SLZ-KF25VA2 SUZ-KA25VA6 SEER SCOP +++ A A + + A B C D E ++ kw SEER kwh/annum A A A + + A B C D E 2,6 kw X 6,3 SCOP X 144 kwh/annum X ++ A + 2,2 716 X X X 48 db 58 db 626/2011

2 SLZ-KF25VA2 SUZ-KA25VA , , ,2 2,0 (-10 C) SLZ-KF35VA2 SUZ-KA35VA , , ,6 2,3 (-10 C) R410A GWP 1975 *1 SLZ-KF50VA2 SUZ-KA50VA , , ,6 3,2 (-10 C) SLZ-KF60VA2 SUZ-KA60VA , ,6 4, ,6 4,0 (-10 C) 2,0 (-7 C) 2,3 (-7 C) 3,2 (-7 C) 4,0 (-7 C) 2,0 (-10 C) 2,3 (-10 C) 3,2 (-10 C) 4,0 (-10 C) 0,2 0,3 0,4 0,6

3

4 PRODUCT IFORMATIO (*) IDOOR MODEL PACKAGED AIR CODITIOER SLZ-KF25VA2 OUTDOOR MODEL SUZ-KA25VA6 If function includes heating: Indicate the heating season the Function (indicate if present) information relates to. Indicated values should relate to one heating season at a time. Include at least the heating season Average (mandatory) cooling Warmer (if designated) heating Colder (if designated) Item symbol value unit Item symbol value unit Design load Seasonal efficiency cooling Pdesignc 2.6 kw cooling SEER heating/average Pdesignh 2.2 kw heating/average SCOP/A heating/warmer Pdesignh x kw heating/warmer SCOP/W heating/colder Pdesignh x kw heating/colder SCOP/C Declared capacity for cooling, at indoor temperature 27(19) Declared energy efficiency ratio, at indoor temperature 27(19) and outdoor temperature Tj and outdoor temperature Tj Tj=35 Pdc 2.6 kw Tj=35 EERd Tj=30 Pdc 2.0 kw Tj=30 EERd Tj=25 Pdc 1.5 kw Tj=25 EERd Tj=20 Pdc 1.5 kw Tj=20 EERd Declared capacity for heating/average season, at indoor Declared coefficient of performance/average season, at indoor Tj=-7 Pdh 2.0 kw Tj=-7 COPd Tj=2 Pdh 1.2 kw Tj=2 COPd Tj=7 Pdh 1.2 kw Tj=7 COPd Tj=12 Pdh 1.4 kw Tj=12 COPd Tj=bivalent temperature Pdh 2.0 kw Tj=bivalent temperature COPd Tj=operating limit Pdh 2.0 kw Tj=operating limit COPd Declared capacity for heating/warmer season, at indoor Declared coefficient of performance/warmer season, at indoor temperature 20 and outdoor temperature Tj Tj=2 Pdh x kw Tj=2 COPd Tj=7 Pdh x kw Tj=7 COPd Tj=12 Pdh x kw Tj=12 COPd Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd Tj=operating limit Pdh x kw Tj=operating limit COPd Declared capacity for heating/colder season, at indoor Declared coefficient of performance/colder season, at indoor temperature 20 and outdoor temperature Tj Tj=-7 Pdh x kw Tj=-7 COPd Tj=2 Pdh x kw Tj=2 COPd Tj=7 Pdh x kw Tj=7 COPd Tj=12 Pdh x kw Tj=12 COPd Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd Tj=operating limit Pdh x kw Tj=operating limit COPd Tj=-15 Pdh x kw Tj=-15 COPd Bivalent temperature Operating limit temperature heating/average Tbiv -7 heating/average Tol -10 heating/warmer Tbiv x heating/warmer Tol x heating/colder Tbiv x heating/colder Tol x Cycling interval capacity Cycling interval efficiency for cooling Pcycc x kw for cooling EERcyc for heating Pcych x kw for heating COPcyc Degradation co-efficient cooling Cdc Degradion co-efficient heating Cdh Electric power input in power modes other than 'active mode' Annual electricity consumption off mode POFF 6 W cooling QCE 144 kwh/a standby mode PSB 6 W heating/average QHE 716 kwh/a thermostat - off mode PTO(c/h) 5 W heating/warmer QHE x kwh/a crankcase heater mode PCK 0 W heating/colder QHE x kwh/a

5 Capacity control (indicate one of three options) fixed Other items Sound power level (indoor/outdoor) LWA 48/58 db(a) staged Global warming potential GWP 1975 kgco2eq. variable Rated air flow (indoor/outdoor) - 660/1956 m3/h Contact details for obtaining more information ame and address of the manufacturer or of its authorized representative. (*) This information is based on the "product information requirement" in COMMISSIO REGULATIO (EU) o206/2012.

6 TECHICAL DOCUMETATIO ( 1 ) IDOOR MODEL SLZ-KF25VA2 245H570W570D (mm) PACKAGED AIR CODITIOER OUTDOOR MODEL SUZ-KA25VA6 550H800W285D (mm) Function cooling heating The heating season Average (mandatory) Warmer (if designated) Colder (if designated) Capacity control fixed staged variable Item Seasonal efficiency ( 2 ) symbol value unit cooling SEER heating/average SCOP/A heating/warmer SCOP/W heating/colder SCOP/C Energy efficiency class cooling SEER + - heating/average SCOP/A - heating/warmer SCOP/W heating/colder SCOP/C Other items Sound power level (indoor/outdoor) LWA 48/58 db(a) Refrigerant - R410A - Global warming potential GWP 1975 kgco2eq. identification and signature of the person empowered to bind the supplier Akira Hidaka Department Manager, Quality Assurance Department MITSUBISHI ELECTRIC COSUMER PRODUCTS (THAILAD) CO.,LTD (1) This information is based on COMMISSIO DELEGATED REGULATIO (EU)o626/2011. (2) SEER/SCOP values are measured based on FprE 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance.