1

2 AXEON Tap Water Reverse Osmosis Systems SECTION 1 AXEON CRO Series Reverse Osmosis System AXEON L1 Series Reverse Osmosis Systems AXEON R1 Series Reverse Osmosis Systems AXEON M1 Series Reverse Osmosis Systems AXEON X1 Series Reverse Osmosis Systems FLEXEON Tap Water Reverse Osmosis Systems SECTION 2 FLEXEON RF Series Residential Reverse Osmosis Systems FLEXEON LP Series Reverse Osmosis Systems FLEXEON LC Series Reverse Osmosis Systems FLEXEON AT Series Reverse Osmosis Systems FLEXEON BT Series Reverse Osmosis Systems FLEXEON CT Series Reverse Osmosis Systems FLEXEON DT Series Reverse Osmosis Systems FLEXEON HT Series Reverse Osmosis Systems FLEXEON JT Series Reverse Osmosis Systems FLEXEON ST Series Reverse Osmosis Systems Brackish Water Reverse Osmosis Systems SECTION 3 AXEON R2 Series Reverse Osmosis Systems AXEON M2 Series Reverse Osmosis Systems AXEON X2 Series Industrial Reverse Osmosis Systems Sea Water Reverse Osmosis Systems SECTION 4 AXEON T3 Series Reverse Osmosis Systems AXEON S3 Series Reverse Osmosis Systems AXEON X3 Series Industrial Reverse Osmosis Systems

3 Electrodeionization Systems SECTION 5 AXEON EDI Series Electrodeionization Systems Membrane Cleaning Systems SECTION 6 AXEON CIP Series Clean In Place Systems Water Filtration Systems SECTION 7 AXEON Zeolite Treatment Systems AXEON Activated Carbon Treatment Systems AXEON Filox Iron Reduction Treatment Systems Water Softening Systems SECTION 8 AXEON Water Softening Treatment Systems AXEON Twin Softening Treatment Systems Chemical Injection Systems SECTION 9 AXEON XP Series Chemical Injection Systems P.A.E. Metal Bladder Tanks Pentair ROmate Fiberglass Bladder Tanks AXEON Atmospheric Tanks About AXEON Water Technologies AXEON Water Technologies, the leading manufacturer of commercial and industrial membrane systems in North America, offers systems, membranes, cartridges, housings and chemicals. By offering cost-effective solutions that yield high quality performance and dependability, AXEON has earned the trust and respect of industry professionals and customers in more than 80 countries around the globe. ii

4 iii Notes

5 1-1

6 CRO Series Reverse Osmosis System AXEON CRO Series Reverse Osmosis System utilizes reverse osmosis technology and features a four stage pre filter, membrane and post filter design that is housed inside a single cartridge. A fifth stage post polishing inline carbon filter is installed between the tank and faucet for even better tasting water. The system includes a two gallon white storage tank, faucet, tubing and quick connect fittings for a fast and easy installation. Stage 1 20 Micron Sediment Pre Filter Stage 2 GAC Pre Filter Stage 3 50 GPD Thin Film Composite Reverse Osmosis Membrane Stage 4 Post Carbon Filter CRO 50 Reverse Osmosis System Stage 5 In Line GAC Post Filter Benefits Superior Product to Waste Ratio Can Reduce Water Waste by 50%, More Water to the Tank and Less Water to the Drain High Flow Membrane Ensures Faster Tank Refilling Small Footprint for Easy Installation 1-2

7 CRO Series Reverse Osmosis System With only one main cartridge and one inline carbon filter, the AXEON CRO Series Reverse Osmosis System saves time and money on service calls and replacement cartridges. No preliminary tank or unit assembly is required. The tank, feed and drain lines are pre plumbed in the unit and tested at the factory. Final onsite installation is fast and simple. The AXEON CRO Series Reverse Osmosis System incorporates 3/8 tubing for faucet and tank connections. The larger diameter tubing ensures faster flow rate of approximately 30% from the faucet. Feedwater Requirements Pressure (psi / bar) / Temperature ( F / C) / 4 38 TDS (ppm) <1000 Turbidity (NTU) <1 NTU SDI <5 ph 4 8 Chlorine (ppm) <1.0 Feedwater must be potable, municipal water. Must be free of potential membrane foulants such as Iron, Hydrogen Sulfide and Manganese. Performance Specifications Model # CRO 50 Membrane Production (gpd / lpd) 50 / Waste to Product 1.67:1 TDS Reduction % 96.5 Arsenic V Reduction % 97.8 Cysts Reduction % >99.99 Fluoride Reduction % 96.3 Lead Reduction % 98.0 Tested at 60 psi (4 bar), 500ppm TDS municipal water, 77 F (25 C). CRO 50 Complete System with Tubing and In line Post filter Replacement Cartridges Part Number Stage Description Replacement Interval 4 Stage Cartridge 1) 20 Micron Sediment Pre Filter ) Granular Activated Carbon Prefilter 12 Months 3) Reverse Osmosis Membrane 4) Granular Activated Carbon Post Filter Granular Activated Carbon Post Filter (In Line between Tank and Faucet) 6 12 Months CRO 50 Reverse Osmosis System Exploded View Part Number Model Number Systems Capacity (gpd / lpd) Product to Waste Ratio Nominal TDS Reduction % Dimensions L x W x H (in / mm) Shipping Weight (lbs / kg) CRO / 189 1: x x / x x / 5 Feedwater must be potable, municipal water. Must be free of potential foulants such as Iron, Hydrogen Sulfide and Maganese. Tested at 60 psi (4 bar), 500ppm TDS municipal water, 77ªF (25ªC) axeonwater.com MKTF-204-D AXEON is a registered trademark of AXEON Water Technologies. 12/ AXEON Water Technologies 1-3

8 L1 Series Reverse Osmosis Systems AXEON L1 Series Reverse Osmosis Systems are a cost effective solution for light commercial reverse osmosis applications such as coffee, tea, food preparation, misting, hydroponics, detailing and more. AXEON L1 Series Reverse Osmosis Systems feature a compact wall mount space saving design and comes pre assembled and ready for immediate service with simple utility connections. These systems are available in capacities of 200 and 300 gallons per day and feature a single pump design for reliable performance. Each model is engineered with quality AXEON components including fiberglass (FRP) membrane housings, extra low energy membranes, pressure gauges, filters and housings. Features AXEON HF4 Series Extra Low Energy Membrane Elements AXEON FRP Series 300E Fiberglass Membrane Housing AXEON 5 Micron Sediment Pre Filter AXEON 10 Micron Carbon Block Pre Filter and Post Filter AXEON by Pentek 10 Slim Line Cartridge Housings AXEON psi Glycerin Filled Pump Pressure Gauge AXEON psi Glycerin Filled Pre Filter Pressure Gauge AXEON psi Glycerin Filled Permeate Pressure Gauge Aquatec Tank High Pressure Switch Composite Feed Solenoid Valve Aquatec Auto Flush Timer Valve AXEON L1 300 Wall Mount Reverse Osmosis System Aquatec High Flow Booster Pump John Guest Push/Pull Fittings with Locking Safety Clips Options and Upgrades 10 and 20 Floor Stands AXEON HF5 Series Ultra Low Energy Membrane Elements AXEON SS Series Membrane Housing TDS Dual Monitor 1-4

9 L1 Series Reverse Osmosis Systems Product Specifications Models L1 200 L1 300 Design Configuration Single Pass Single Pass Feedwater Source TDS <1000 TDS <1000 Standard Recovery Rate 40% 50% Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 0.14 / / 0.79 Minimum Concentrate Flow (gpm / lpm) 0.21 / / 0.79 Connections Feed FNPT (in) 3/8 QC 3/8 QC Permeate FNPT (in) 3/8 QC 3/8 QC Concentrate FNPT (in) 1/4 QC 1/4 QC Membranes Membrane(s) Per Vessel 1 1 Membrane Quantity 1 1 Membrane Size Vessels Vessel Array 1 1 Vessel Quantity 1 1 Standard Pump Pump Type Aquatec 8800 Aquatec 5800 System Electrical Standard Voltage + Amp Draw 110V, 60Hz, 1PH, 4.0A 110V, 60Hz, 1PH, 4.0A High Voltage Service + Amp Draw 220V, 50Hz, 1PH, 2A 220V, 50Hz, 1PH, 2A Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 9 x 18 x 19 / 22.9 x 45.7 x x 27 x 19 / 22.9 x 68.6 x 48.3 Approximate Weight (lbs / kg) 42 / / 22.7 Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 100 psi / 6.9 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. Operating Limits Design Temperature ( F / C) 77 / 25 Maximum Turbidity (NTU) 1 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum TDS (ppm) 1,000 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum Hardness (gpg) 1 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum ph (Continuous) 11 Maximum Feed Pressure (psi / bar) 85 / 6 Minimum ph (Continuous) 2 Minimum Feed Pressure (psi / bar) 45 / 3 Maximum ph (Cleaning 30 Minutes) 13 Maximum Operating Pressure (psi / bar) 110 / 7.5 Minimum ph (Cleaning 30 Minutes) 1 Maximum Feed Silt Density Index (SDI) <3 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-247-C AXEON is a registered trademark of AXEON Water Technologies. 10/ AXEON Water Technologies 1-5

10

11 R1 Series Reverse Osmosis Systems R1 Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and operation costs. R1 Series Reverse Osmosis Systems feature a new, innovative design. These systems feature only the highest quality components, including a programmable computer controller with many built in standard features, a stainless steel booster pump for high performance and corrosion resistance, ultra low energy membranes and fiberglass membrane housings for enhanced performance and durability. R1 Series Reverse Osmosis Systems have been engineered for capacities ranging from 1,800 21,600 gallons per day. R Reverse Osmosis System Benefits Fully Equipped and Customizable Skid Mounted Decreased Size of Dimensional Footprint from Standard Reverse Osmosis Systems Components Easily Accessible Pre Plumbed, Wired and Assembled Individually Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 20% Less Energy Use than Standard Reverse Osmosis Systems 1 Year Limited Warranty 1-7

12 Standard Features S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm TDS Monitoring Feed Flush Hour Meter AXEON Permeate and Concentrate Flow Meters AXEON Concentrate Recycle with Flow Meter AXEON Pre Filter psi Panel Mounted Glycerin Filled Gauges AXEON Pump Discharge and Concentrate psi Panel Mounted Glycerin Filled Gauges AXEON 5 Micron Sediment Pre Filter AXEON HF5 Series Ultra Low Energy Membrane Elements AXEON FRP Series Membrane Housings 300 psi R Reverse Osmosis System AXEON by Pentek 20 Big Grey Cartridge Housings Goulds Multi Stage Stainless Steel Booster Pump ASCO Composite Feed Solenoid Valve Feed Low Pressure Switch White Powder Coated Aluminum Frame Dual Chemical Pump Outlets Options and Upgrades S 150 Expander Board S 150 Dual TDS Board and Sensor Filmtec LCLE Membrane Elements AXEON SS Series Membrane Housings AXEON NF3 Series Membrane Elements AXEON NF4 Series Membrane Elements AXEON HR3 Series Membrane Elements Permeate Flush Permeate Divert Permeate Sample Flush Pump Pressure Relief Valve Blending Valve High Pressure Tank Switch Wooden Crate Hanna BL ph Controller 1-8

13 Notes: 1. All dimensions are given in inches. 2. R AXEON model shown. FM CONCENTRATE RECYCLE VALVE WATER INLET SOV 20 FILTER HOUSING PI x2 5 MICRON SEDIMENT LPS REVERSE OSMOSIS PUMP FLOW METER CONCENTRATE RECYCLE PI HF5 MEMBRANES PI CV * TDS CONCENTRATE VALVE FM FLOW METER PERMEATE FM FLOW METER CONCENTRATE DRAIN POINT OF USE * Two check valves in parallel for models R1 6140, R1 8140, R and R Array Specifications Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity R R : R :1: R :1:1: R :1:1:1: R :2: R :2:2: R :2:2:2: R :2:2:2:2:

14 R1 Series Reverse Osmosis Systems Product Specifications Models R R R R R R R R R Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater TDS max (ppm) 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 Standard Recovery % Rejection and Flow Rates Permeate Flow Rate 1,800 / (gpd / lpd) 6,813 Permeate Flow Rate (gpm / lpm) Minimum Concentrate Flow Rate (gpm / lpm) Concentrate Recycle Flow Rate (gpm / lpm) Connections 3,600 / 13,627 5,400 / 20,441 7,200 / 27,254 9,000 / 34,068 10,800 / 40,882 14,400 / 54,509 18,000 / 68,137 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum TDS (ppm) 2,000 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum Hardness (gpg) 0 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum ph (Continuous) 11 Maximum Feed Pressure (psi / bar) 85 / 6 Minimum ph (Continuous) 2 Minimum Feed Pressure (psi / bar) 45 / 3 Maximum ph (Cleaning 30 Minutes) 13 Maximum Pressure (psi / bar) 200 / 14 Minimum ph (Cleaning 30 Minutes) 1 Maximum Feed Silt Density Index (SDI) <3 Maximum Turbidity NTU 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow. Design conditions are not identical to test conditions, please contact the manufacturer or your supplier for more information. 21,600 / 81, / / / / / / / / / / / / / / / / / / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Up to 5 / Feed Connection (in) 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Permeate Connection (in) 3/4 FNPT 3/4 FNPT 3/4 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Concentrate Connection (in) 3/4 FNPT 3/4 FNPT 3/4 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Nominal TDS Rejection % Vessels Vessel Array 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 2:2:2 2:2:2:2 2:2:2:2:2 2:2:2:2:2:2 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Motor HP RPM at 60 Hz System Electrical Standard Voltage + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 220V, 60Hz, 1PH, 8.8A** 26 x 26 x 60 / x x V, 60Hz, 1PH, 8.8A** 26 x 26 x 60 / x x V, 60Hz, 1PH, 8.8A** 26 x 26 x 60 / x x V, 60Hz, 1PH, 8.8A** 32 x 26 x 60 / x x V, 60Hz, 1PH, 16A** 32 x 26 x 60 / x x V, 60Hz, 1PH, 16A** 32 x 26 x 60 / x x V, 60Hz, 1PH, 16A** 32 x 50 x 60 / x 127 x V, 60Hz, 1PH, 16A** 32 x 50 x 60 / x 127 x V, 60Hz, 1PH, 16A** 32 x 50 x 60 / x 127 x Approximate Weight 250 / / / / / / / / / (lbs / kg) Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 80 psi / 5.5 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits axeonwater.com 1-10 MKTF-110-E AXEON is a registered trademark of AXEON Water Technologies. 07/ AXEON Water Technologies

15 M1 Series Reverse Osmosis Systems M1 Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and low operation costs. The M1 Series Reverse Osmosis Systems range in capacities from 12,000 to 36,000 gallons per day. To achieve higher recovery rates, each base model includes a concentrate recycle loop. These systems can be upgraded with features such as a variable frequency drive, digital instrumentation, a chemical feed system, blending valve and a permeate divert valve. M Reverse Osmosis System Benefits Fully Equipped and Customizable Skid Mounted Components Easily Accessible Pre Plumbed, Wired and Assembled Individually Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 20% Less Energy than Standard Membranes 1 Year Limited Warranty 1-11

16 Features Models: M1 4240, M1 6240, M S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm Hour Meter Feed Flush Models: M , M S 200 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm Hour Meter Dual TDS Monitoring Feed Flush Digital Flow Meters x 3 Rejection Percentage Recovery Percentage M Reverse Osmosis System AXEON Permeate and Concentrate Flow Meters* AXEON Concentrate Recycle Flow Meter* Stainless Steel Concentrate Globe Valve AXEON Pre Filter psi Panel Mounted Glycerin Filled Gauges AXEON Pump Discharge and Concentrate psi Panel Mounted Glycerin Filled Gauges AXEON Bag Filter Housing with Stainless Steel Stand AXEON 5 Micron Filter Bag AXEON HF5 Series Ultra Low Energy Membrane Elements AXEON FRP Series Membrane Housings 300 psi Vertical Multi Stage Stainless Steel Booster Pump Feed Solenoid Valve Feed Low Pressure Switch Clean In Place (CIP) Ports Permeate Sample Ports White Powder Coated Aluminum Frame Wooden Shipping Crate Options and Upgrades S 150 Expander Board* S 150 Dual TDS Board* S 200 Computer Controller* AXEON NF3 Series Nanofiltration Membrane Elements AXEON NF4 Series Nanofiltration Membrane Elements Hanna BL ORP Meter* Hanna BL ph Meter* S 200 ORP Monitoring* S 200 ph Monitoring* Chemical Pump Outlet Blending Valve High Pressure Tank Switch Pump Pressure Relief Valve ** Caster Wheels Permeate Divert Variable Frequency Drive AXEON Naming Matrix M M-SERIES MODEL M1 Tap Water Model HOUSING QUANTITY DESIGNATION 4 4 Vessel 6 6 Vessel 8 8 Vessel Vessel Vessel MEMBRANE QUANTITY PER HOUSING ø 2 2 Membranes 4.0 INCH MEMBRANE DIAMETER * Only available on the following models: M1 4240, M1 6240, M ** Standard for all 50Hz Systems 1-12

17 Notes: 1. All dimensions are given in inches. 2. Model M AXEON model shown. Array Specifications Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity M : M :2: M :3: M :3:2: M :3:2:2:

18 M1 Series Reverse Osmosis Systems Operating Limits Product Specifications Models M M M M M Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater Source TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 8.30 / / / / / Minimum Feed Flow (gpm / lpm) / / / / / Maximum Feed Flow (gpm / lpm) / / / / / Minimum Concentrate Flow (gpm / lpm) 6.00 / / / / / Connections Feed (in) 1.5 FNPT 1.5 FNPT 1.5 FNPT 1.5 FNPT 1.5 FNPT Permeate (in) 1 FNPT 1 FNPT 1 FNPT 1.5 FNPT 1.5 FNPT Concentrate (in) 1 FNPT 1 FNPT 1 FNPT 1.5 FNPT 1.5 FNPT CIP (in) 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 2:2 2:2:2 3:3:2 3:3:2:2 3:3:2:2:2 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Motor HP Hz Hz System Electrical Standard Voltage + Amp Draw 220V, 60Hz, 3PH, 9A** 220V, 60Hz, 3PH, 9A** 220V, 60Hz, 3PH, 14.2A** 220V, 60Hz, 3PH, 19.5A** 220V, 60Hz, 3PH, 19.5A** Voltage Options + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 220V, 50Hz, 3PH, 10.6A** 460V, 60Hz, 3PH, 5A** 31 x 100 x 64 / x 254 x V, 50Hz, 3PH, 10.6A** 460V, 60Hz, 3PH, 5A** 31 x 100 x 64 / x 254 x V, 50Hz, 3PH, 16.1A** 460V, 60Hz, 3PH, 7A** 31 x 100 x 64 / x 254 x V, 50Hz, 3PH, 22.9A** 460V, 60Hz, 3PH, 9.7A** 31 x 100 x 64 / x 254 x V, 50Hz, 3PH, 22.9A** 460V, 60Hz, 3PH, 9.7A** 31 x 100 x 64 / x 254 x Approximate Weight (lbs / kg) 1060 / / / / / Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 80 psi / 5.5 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 5 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 2000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 200 / 14 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com 1-14 MKTF-112-E AXEON is a registered trademark of AXEON Water Technologies. 06/ AXEON Water Technologies

19 X1 Series Reverse Osmosis Systems X1 Series Reverse Osmosis Systems are designed as a cost effective solution to the growing demand of tap and well water for applications in food and beverage, pharmaceutical, healthcare, microelectronics, power, chemicals and agriculture. X Industrial Reverse Osmosis System With models ranging from 22 to 132 gallons per minute (32,000 to 190,000 gallons per day), the smart, clean utilitarian industrial design of the X1 Series allows for convenient installation, user friendly operation and ease of maintenance. These skid mounted, package systems are pre plumbed and pre wired on a powder coated steel frame complete with a pre programmed computer controller, TDS probes and panel mounted pressure gauges and flow instrumentation, allowing for straight forward system monitoring and control. The X1 Series Systems utilize energy efficient ultra low energy membranes with 10% greater membrane surface area than standard 8 inch reverse osmosis elements, thus producing more pure water. 1-15

20 Standard Features S 150 Pre Programmed Computer Controller* S 200 Pre Programmed Computer Controller with VFD (Variable Frequency Drive)** 8 inch Low Energy Membrane Elements (440 SF) 8 inch Fiberglass Membrane Housings with Stainless Steel Side Ports (300 psi) 5 Micron Sediment Cartridge Filters X Industrial Reverse Osmosis System Feed and Permeate TDS Powder Coated Carbon Steel Multi Cartridge 304L Stainless Steel Cartridge Housing Permeate and Concentrate Rotameters* Permeate and Concentrate Digital Paddlewheel Sensors** Pre and Post Filter Pressure Gauges Pump Pressure and Concentrate Pressure Gauges Composite Feed Solenoid Valve* Motorized Feed Valve** Stainless Steel Globe Throttling Valves* Low and High Pressure Shut Off Switches Efficient Vertical Stainless Steel Multi Stage Pump Frame Sch80 PVC Piping Clean In Place (CIP) Ports with Valves Permeate Sample Valves Chemical Feed Ports Chemical Feed Power Outlet 220VAC 3PH 60HZ Options and Upgrades S 200 Computer Controller*** VFD*** Programmable Logic Controller (PLC) with Touch Screen Permeate and Concentrate Digital Paddlewheel Sensors*** PVC Feed Motorized Ball Valve*** Concentrate Recycle Loop with Flow Meter PVC Permeate Divert Motorized Ball Valve Permeate Flush ph Sensor ORP Sensor Chemical Feed System Clean In Place Skid Mounted System Voltage Options: 220VAC 3PH 50Hz, 380VAC 3PH 50Hz, 460VAC 3PH 60Hz * Standard on Models X1 2280, X1 3280, X1 4280, X ** Standard on Models X1 3480, X1 4480, X1 5480, X *** Option available for Models X1 2280, X1 3280, X1 4280, X Standard on larger models. 1-16

21 Notes: 1. All dimensions are given in inches. 2. Dimensions given for X through X (X pictured) Notes: 1. All dimensions are given in inches. 2. Dimensions given for X through X (X pictured) 1-17

22 X1 Series Reverse Osmosis Systems Product Specifications Models X X X X X X X X Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater Source TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm Design Temperature ( F / C) 77 / 25 Maximum SDI Rating (SDI) < 3 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum ph (Continuous) 11 Minimum Ambient Temperature ( F / C) 40 / 4 Minimum ph (Continuous) 2 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Cleaning 30 Minutes) 13 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Cleaning 30 Minutes) 1 Maximum Piping Pressure (psi / bar) 200 / 18.7 Maximum Turbidity (NTU) < 1 TDS <2,000 ppm Standard Recovery % Recovery with Concentrate Recycle gpm % N/A N/A N/A N/A N/A Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow Rate (gpm / lpm) Minimum Concentrate Flow Rate (gpm / lpm) Connections / / / / / / / / / / / / / / / / 167 Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT 3 FNPT 3 FNPT Permeate Connection (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 1/2 FNPT 2 1/2 FNPT 3 FNPT 3 FNPT Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT Clean in Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1:1 1:1:1 1:1:1:1 2:1:1:1 2:1 2:1:1 3:1:1 3:2:1 Vessel Quantity Pumps Pump Type Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Vertical Multi Stage Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Centrifugal Pump Motor HP / KW 10 / / / / / / / / 11 System Electrical Standard Voltage + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) Approximate Weight (lbs / kg) 208V 230V, 60Hz, 3PH, 28A 27A** 112 x 35 x 74 / 284 x 89 x V 230V, 60Hz, 3PH, 28A 27A** 112 x 35 x 74 / 284 x 89 x V 230V, 60Hz, 3PH, 28A 27A** 112 x 35 x 74 / 284 x 89 x V 230V, 60Hz, 3PH, 28A 27A** 112 x 35 x 74 / 284 x 89 x V 230V, 60Hz, 3PH, 40.5A 37A** 194 x 41 x 78 / 493 x 104 x V 230V, 60Hz, 3PH, 40.5A 37A** 194 x 41 x 78 / 493 x 104 x V 230V, 60Hz, 3PH, 49A** 194 x 41 x 78 / 493 x 104 x V 230V, 60Hz, 3PH, 49A** 194 x 41 x 84 / 493 x 104 x 213 1,285 / 583 1,435 / 651 1,585 / 719 1,735 / 787 2,005 / 910 2,275 / 1,032 2,645 / 1,200 2,910 / 1,320 Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 100 psi / 6.9 bar Operating Pressure 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-373-E AXEON is a registered trademark of AXEON Water Technologies. 08/ AXEON Water Technologies

23 2-1

24 2-2 Notes

25 RF Series Residential Reverse Osmosis Systems FLEXEON 5 Stage RF Reverse Osmosis System FLEXEON RF Series Residential Reverse Osmosis Systems combine advanced reverse osmosis and carbon filtration technologies to produce the best quality water available for point of use applications. Features TF Series Residential Membrane Elements High Quality Pre and Post Filters 4 Gallon Storage Tank Faucet, Wrench and Tubing Included Available in 25 GPD to 200 GPD Configurations Available with Booster Pump Quick Connect Fittings 100% Tested and Assembled in the USA 2-3

26 4 Stage Reverse Osmosis Systems AXEON 5 Micron Sediment Filter AXEON Carbon Block AXEON Inline Post Carbon AXEON Reverse Osmosis Membrane AXEON by Pentek Slim Line Filter Housings Housing Filter Wrench All Necessary Components for Quick and Easy Installation John Guest Quick Connect Fittings Long Reach Non Air Gap Faucet 100% Tested and Assembled In The USA 1 Year Limited Warranty P.A.E. 4 Gallon White Storage Tank Part Number Description SYSTEM, REVERSE OSMOSIS, 4 STAGE, RF 4000 SERIES, FLEXEON 5 Stage Reverse Osmosis Systems AXEON 5 Micron Sediment Filter AXEON Carbon Block AXEON Inline Post Carbon AXEON Reverse Osmosis Membrane AXEON by Pentek Slim Line Filter Housings Housing Filter Wrench P.A.E. 4 Gallon White Storage Tank All Necessary Components For Quick and Easy Installation John Guest Quick Connect Fittings 100% Tested and Assembled In The USA 1 Year Limited Warranty Long Reach Non Air Gap Faucet Part Number Description SYSTEM, REVERSE OSMOSIS, 5 STAGE, RF 5000 SERIES, FLEXEON 5 Stage Reverse Osmosis Systems with Booster Pump AXEON 5 Micron Sediment Filter AXEON Carbon Block AXEON Inline Post Carbon AXEON Reverse Osmosis Membrane AXEON by Pentek Slim Line Filter Housings Aquatec 8800 Booster Pump P.A.E. 4 Gallon White Storage Tank All Necessary Components For Quick and Easy Installation John Guest Quick Connect Fittings 100% Tested and Assembled In The USA 1 Year Limited Warranty Long Reach Non Air Gap Faucet Part Number Description SYSTEM, REVERSE OSMOSIS, 5 STAGE, RFP 5000 SERIES, FLEXEON 2-4

27 Membrane Options for All Systems RF Series Residential Reverse Osmosis Systems Part Number Description OPTION, KIT, 25 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 35 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 50 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 75 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 100 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 150 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON OPTION, KIT, 200 GPD, REVERSE OSMOSIS, MEMBRANE, FLOW RESTRICTOR, AXEON Specifications System Specifications Tank Capacity 4 Gallons / psi Tank Dimensions (in / cm) 11 x 14 / 27.9 x 35.6 Recovery Rate Ratio 1:4 System Weight (lb / kg) 25 / System Dimensions (in / cm) 7 x 16 x 17 / 17.7 x 40.6 x 43.1 Shipping Box Dimensions (in / cm) 18 x 19 x 20 / 45.7 x 48.2 x 50.8 General Operating Specifications * Nominal Salt Rejection % 98 Operating Pressure (psi / bar) / Operating Temperature ( F / C) / Water Hardness (gpg) <10 TDS (ppm) <1000 A Pressure Regulator is to be Installed Prior to the System. * All Weights and Dimensions are Approximate axeonwater.com MKTF-115-C AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 4/ AXEON Water Technologies 2-5

28 LP Series Reverse Osmosis Systems FLEXEON LP Series Reverse Osmosis Systems are engineered in response to the need within the light commercial market for a system without a pump. The LP Series systems provide a cost effective solution for customers and are easy to install and maintain. These systems are designed to be wall mounted, and feature a 5 Micron Sediment and 10 Micron Carbon Pre Filters, AXEON by Pentek Slim Line Cartridge Housings, AXEON 500 GPD membrane and membrane housing. FLEXEON LP Series Reverse Osmosis Systems are available in models ranging from 350 to 700 gallons per day (GPD), at a line pressure of 70 psi (LP 350 and LP 700). The LP 500 model is also available with a pump to deliver 500 GPD. The models can also be upgraded with a cover that includes AXEON pressure gauges and a 20 floor stand. Features n AXEON TF Membrane Element n AXEON 3012 Membrane Housing n AXEON 2.5 x 20 5 Micron Sediment Pre Filter n AXEON 2.5 x Micron Carbon Block Pre Filter and Post Filter n AXEON by Pentek 20 Slim Line Cartridge Housings n Automatic Shut Off Valve n John Guest Push/Pull Fittings with Locking Safety Clip FLEXEON LP 750 Reverse Osmosis System with optional cover, pressure gauges and TDS meter Options and Upgrades n 20 Floor Stand n Cover with AXEON Glycerin Filled Pressure Gauges Including: n Post Filter Pressure Gauge n Operational Pressure Gauge n Permeate Pressure Gauge n HM Digital DM 2 Dual TDS Meter n Cover without Pressure Gauges n Blending Valve 2-6

29 LP Series Reverse Osmosis Systems Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. Product Specifications Models LP 350 LP 500 LP 700 Design Configuration Single Pass Single Pass Single Pass Feedwater Source TDS <250 ppm TDS <500 ppm TDS <250 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 0.25 / / / 1.89 Minimum Feed Flow (gpm / lpm) 1.95 / / / Maximum Feed Flow (gpm / lpm) 8.00 / / / Connections Feed Connection (in) 3/8 QC 3/8 QC 3/8 QC Permeate Connection (in) 3/8 QC 3/8 QC 3/8 QC Concentrate Connection (in) 1/4 QC 1/4 QC 1/4 QC Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1 1 1:1 Vessel Quantity Pumps Pump Included No Yes No Pump Type N/A Aquatec 5800 N/A System Electrical Standard Voltage + Amp Draw N/A 110V, 50 / 60Hz, 1PH, 4A N/A Systems Dimensions Approximate Dimensions* L x W x H (in / cm) x x / x x x x / x x x x / x x Approximate Weight (lbs / kg) 35 / / / Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 50 / 10 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 500 ppm Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 1 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 80 / 6 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <1 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-369-B AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 10/ AXEON Water Technologies 2-7

30 LC Series Reverse Osmosis Systems FLEXEON LC Series Reverse Osmosis Systems are manufactured for light commercial applications and feature a compact space saving design. The versatile design allows for either wall mounted or freestanding operation. The LC Series Systems come preassembled and ready for immediate online service with minimal set up and simple utility connections. FLEXEON LC Series Reverse Osmosis Systems have been engineered for capacities ranging from 750 to 1,500 gallons per day and feature a Fluid O Tech TM Low Lead Brass Rotary Vane Pump designed for enhanced performance. Features White Powder Coated Steel Bracket AXEON 2.5 x 20 5 Micron Sediment Pre Filter AXEON 2.5 x Micron Carbon Block Pre Filter (on LC 750) AXEON by Pentek 20 Slim Line Cartridge Housings Fluid O Tech TM Low Lead Brass Rotary Vane High Pressure Pump ODP High Efficiency Carbonator Motor AXEON HF5 Series Ultra Low Energy Membrane Elements Permeate Flow Meter Concentrate Flow Meter with SS Integrated Needle Valve Concentrate Recycle Flow Meter with SS Integrated Needle Valve Feed Solenoid Valve psi Pump Pressure Gauge psi Post Filter Pressure Gauge FLEXEON LC 1500 Reverse Osmosis System psi Permeate Pressure Gauge John Guest Push/Pull Fittings with Locking Safety Clips Low Pressure Switch for Pump Protection Permeate High Pressure Switch HM Digital DM 2 Dual TDS Meter 20 Floor Stand Options and Upgrades Fluid O Tech TM Stainless Steel Rotary Vane Pump Blending Valve 2-8

31 LC Series Reverse Osmosis Systems Product Specifications Models LC 750 LC 1500 Design Configuration Single Pass Single Pass Feedwater Source TDS <1,000 ppm TDS <1,000 ppm Standard Recovery Rate % Up to 75 Up to 75 Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 0.52 / / 3.94 Minimum Feed Flow (gpm / lpm) 2.22 / / Maximum Feed Flow (gpm / lpm) Up to 8 / 30.3 Up to 8 / 30.3 Connections Feed Connection (in) 1/2 QC 1/2 QC Permeate Connection (in) 3/8 QC 3/8 QC Concentrate Connection (in) 3/8 QC 3/8 QC Membranes Membrane(s) Per Vessel 1 1 Membrane Quantity 1 2 Membrane Size Vessels Vessel Array 1 1:1 Vessel Quantity 1 2 Pumps Pump Type Rotary Vane 401 Low Lead Brass Rotary Vane 601 Low Lead Brass Motor HP 1/3 1/2 60Hz System Electrical Standard Voltage + Amp Draw 110V, 1 PH, 50 / 60Hz, 6.6A** 110V, 1 PH, 50 / 60Hz, 8.2A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 17 x 13 x 34 / x x x 13 x 34 / x x Approximate Weight (lbs / kg) 50 / / Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 70 psi / 4.83 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) Up to 1,000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 1 Maximum Feed Pressure (psi / bar) 70 / 4 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 40 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 90 / 6 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-385-B AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 01/ AXEON Water Technologies 2-9

32

33 AT Series Reverse Osmosis Systems FLEXEON AT Series Reverse Osmosis Systems set the industry standard with a compact, space saving design with high quality components. These systems are available in capacities of 500 and 1,000 gallons per day and feature 4.5 diameter sediment and carbon block pre filters, low energy membranes, a high pressure pump and a solenoid valve all mounted onto a corrosion resistant, powder coated aluminum frame. FLEXEON AT Series Reverse Osmosis Systems can also be upgraded for higher recovery rates by adding the concentrate recycle option. AT 1000 Reverse Osmosis System Benefits Fully Equipped and Customizable Lightweight Design Compact Space Saving Design Components Easily Accessible Pre Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation Costs Low Maintenance Costs Easy Maintenance and Servicing 1 Year Limited Warranty 2-11

34 Features Manual On and Of f White Powder Coate AXEON 5 Micron AXEON 10 Micro AXEON by Pentek Fluid O Tech Low Lead Control Switch ed Aluminum Frame Sediment Pre Filter n Carbon Block Pre Filter Single O Ring Filter Hou Brass Rotary Vane High Pressure Pump ODP High Efficiency y Carbonator Motor AT 1000 Reverse Osmosis System AXEON HF1 Serie AXEON PVC Serie A XEON Permeate Fl AXEON Concentrate Feed Low Pressure S AXEON Composite AXEON 316L SS S AXEON ps A XEON ps ush/pull Fittings wi t es Low Energy Membrane es Membrane Housings l ow Meter Flow Meter Switch psi Feed Solenoid Valve Series Concentrate Valve i Pump Pressure Gauge i Pre Filter Pressure Gauges P h Locking Safety Clips Options AXEON HF4 Seriee es Extra Low Energy Membrane Ele ements Minitrol IF M Computer Controller with Feed Fl ush AXEON HF5 Serie AXEON NF3 Seri AXEON NF4 Seri AXEON SS Series AXEON FRP Serie C oncentrate Recycle HM Digital PSC Fluid O Tech Stai M initrol Computer C es Ultra Low Energy Membrane Elements es Nanofiltration Membrane Elements es Nanofiltration Membrane Elements s Membrane Housings es Membrane Housings e Valve with Flow Meter 150 TDS/Conductivityty inless C ontroller Steel Rotary Vane Controller Pump S 150 C High Pres Chemical Blending Permeate P ermeate Permeate Permeate Wo ooden Computer Controller with Feed Flush ssure Tank Switch Pump Outlet Valve Flush with Pressure Tank F lush with Atmospheric Tank Flush with Mechanical Float Sample Ports S hipping Crate 2-12

35 Product Specifications Models AT 500 AT 1000 Design Configuration Single Pass Single Pass Feedwater Source TDS <2000 ppm TDS <2000 ppm Standard Recovery Rate % Recovery with Concentrate Recycle % Up to 75 Up to 75 Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 0.35 / / 2.61 Minimum Feed Flow (gpm / lpm) 1.35 / / 6.40 Maximum Feed Flow (gpm / lpm) 3.00 / / Minimum Concentrate Flow (gpm / lpm) 1.00 / / 3.78 Connections Feed Connection (in) 1 FNPT 1 FNPT Permeate Connection (in) 3/8 QC 3/8 QC Concentrate Connection (in) 3/8 QC 3/8 QC Membranes Membrane(s) Per Vessel 1 1 Membrane Quantity 2 3 Membrane Size Vessels Vessel Array 1:1 1:1:1 Vessel Quantity 2 3 Pumps Pump Type Rotary Vane 401 Brass Rotary Vane 601 Brass Motor HP 1/3 1/2 60Hz (50 Hz) 1725 (1465) 1725 (1465) System Electrical Standard Voltage + Amp Draw 110V, 60Hz, 1PH, 6.6A** 110V, 60Hz, 1PH, 8.2A** High Voltage Service + Amp Draw 220V, 60Hz, 1PH, 3.2A** 220V, 50Hz, 1PH, 3.7A** 220V, 60Hz, 1PH, 3.9A** 220V, 50Hz, 1PH, 4.1A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 14 x 20 x 27 / 36 x 51 x x 20 x 27 / 36 x 51 x 69 Approximate Weight (lbs / kg) 65 / / Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Note: All 50Hz systems come standard with AXEON HF4 Series Extra Low Energy Membrane Elements. Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 2000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 150 / 10 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com 2-13 MKTF-146-D AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 02/ AXEON Water Technologies

36

37 BT Series Reverse Osmosis Systems FLEXEON BT Series Commercial Reverse Osmosis Systems further expand the FLEXEON commercial reverse osmosis lineup with three models designed for 1,500, 1,800 and 2,000 gallons per day. Featuring 4.0 diameter sediment and carbon block pre filters, low energy membranes and a high pressure pump, the BT Series sets the industry standard for high performance reverse osmosis systems. These models can also be upgraded with options for higher recovery rates by adding the concentrate recycle option. BT 2000 Reverse Osmosis System Benefits Fully Equipped and Customizable Expandable and Lightweight Design Compact Space Saving Design Components Easily Accessible Pre Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation Costs Low Maintenance Costs Easy Maintenance and Servicing 1 Year Limited Warranty 2-15

38 Features Manual On and Off Control Switch White Powder Coated Aluminum Frame AXEON 5 Micron Sediment Pre Filter BT 2000 Reverse Osmosis System AXEON 10 Micron Carbon Block Pre Filter AXEON by Pentek Single O Ring Filter Housings Fluid O Tech Low Lead Brass Rotary Vane High Pressure Pump ODP High Efficiency Carbonator Motor AXEON HF1 Series Low Energy Membrane Elements AXEON PVC Series Membrane Housings AXEON Permeate Flow Meter AXEON Concentrate Flow Meter Feed Low Pressure Switch psi AXEON Composite Feed Solenoid Valve AXEON 316L Stainless Steel Concentrate Valve AXEON psi Pump Pressure Gauge AXEON psi Pre Filter Pressure Gauges John Guest Push/Pull Fittings with Locking Safety Clips Front Back Options AXEON HF4 Series Extra Low Energy Membrane Elements AXEON HF5 Series Ultra Low Energy Membrane Elements AXEON NF3 Series Nanofiltration Membrane Elements AXEON NF4 Series Nanofiltration Membrane Elements AXEON SS Series Membrane Housings AXEON FRP Series Membrane Housings Concentrate Recycle Valve with Flow Meter HM Digital PSC 150 TDS/Conductivity Controller Fluid O Tech Stainless Steel Rotary Vane Pump Minitrol Computer Controller Minitrol IF Computer Controller with Feed Flush S 150 Computer Controller with Feed Flush High Pressure Tank Switch Chemical Pump Outlet Blending Valve Permeate Flush with Pressure Tank Permeate Flush with Atmospheric Tank Permeate Flush with Mechanical Float Permeate Sample Ports Wooden Shipping Crate 2-16

39 Product Specifications Models BT 1500 BT 1800 BT 2000 Design Configuration Single Pass Single Pass Single Pass Feedwater Source TDS <2000 ppm TDS <2000 ppm TDS <2000 ppm Standard Recovery Rate % Recovery with Concentrate Recycle % Up to 75 Up to 75 Up to 75 Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 1.04 / / / 5.22 Minimum Feed Flow (gpm / lpm) 2.04 / / / 8.89 Maximum Feed Flow (gpm / lpm) 3.00 / / / Minimum Concentrate Flow (gpm / lpm) 1.00 / / / 3.78 Connections Feed (in) 1 FNPT 1 FNPT 1 FNPT Permeate (in) 3/8 QC 3/8 QC 3/8 QC Concentrate (in) 3/8 QC 3/8 QC 3/8 QC Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1:1 1 1:1:1 Vessel Quantity Pumps Pump Type Rotary Vane 601 Brass Rotary Vane 1001 Brass Rotary Vane 1001 Brass Motor HP 3/4 3/4 3/4 60 Hz (50 Hz) 1725 (1465) 1725 (1465) 1725 (1465) System Electrical Standard Voltage + Amp Draw 110V, 60Hz, 1PH, 11.0A** 110V, 60Hz, 1PH, 11.0A** 110V, 60Hz, 1PH, 11.0A** High Voltage Service + Amp Draw Operating Limits 220V, 60Hz, 1PH, 5.6A** 220V, 50Hz, 1PH, 5.6 A** 220V, 60Hz, 1PH, 5.6A** 220V, 50Hz, 1PH, 6.6A** 220V, 60Hz, 1PH, 5.6A** 220V, 50Hz, 1PH, 6.6A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 19 x 23 x 46 / 48 x 58 x x 23 x 46 / 48 x 58 x x 23 x 46 / 48 x 58 x 116 Approximate Weight (lbs / kg) 105 / / / Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Note 1: All 50Hz systems come standard with AXEON HF4 Series Extra Low Energy Membrane Elements. Note 2: BT 1800 Reverse Osmosis Systems come standard with the Concentrate Recycle Valve and Flow Meter options in order to achieve a higher recovery rate. Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 2000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 150 / 10 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com 2-17 MKTF-147-D AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 02/ AXEON Water Technologies

40

41 CT Series Reverse Osmosis Systems FLEXEON CT Series Reverse Osmosis Systems are designed for high performance and are equipped with many standard features in a cost efficient, compact design. FLEXEON CT Series Reverse Osmosis Systems have been engineered for capacities ranging from 4,000 to 7,000 gallons per day. These models include a microprocessor controller with low pressure monitoring and alarm, pre treatment lockout, and tank level input. A TDS monitor, multi stage booster pump, low energy membranes and three pre filters are all part of the standard features. Upgrades such as feed flush and a concentrate recycle loop to increase recovery rates are also available. CT 7000 Reverse Osmosis System Benefits Fully Equipped and Customizable Compact Space Saving Design Components Easily Accessible Pre Plumbed, Wired and Assembled Factory Tested and Preserved Low Operation Costs Low Maintenance Costs Easy Maintenance and Servicing 1 Year Limited Warranty 2-19

42 Features Minitrol Computer Controller Multi Color LED Indicator Status Light Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm CT 7000 Reverse Osmosis System White Powder Coated Aluminum Frame AXEON 5 Micron Sediment Pre Filter AXEON 10 Micron Carbon Block Pre Filter AXEON 1 Micron Sediment Pre Filter Front AXEON by Pentek Single O Ring Filter Housings Goulds Multi Stage Booster Pump AXEON HF1 Series Low Energy Membrane Elements AXEON PVC Series Membrane Housings AXEON Permeate Flow Meter AXEON Concentrate Flow Meter Feed Low Pressure Switch psi AXEON Composite Feed Solenoid Valve HM Digital PSC 150 TDS/Conductivity Controller AXEON 316L Stainless Steel Concentrate Valve AXEON psi Pump Pressure Gauges AXEON psi Concentrate Pressure Gauge AXEON psi Pre Filter Pressure Gauges Back John Guest Push/Pull Fittings with Locking Safety Clips Options AXEON HF4 Series Extra Low Energy Membrane Elements AXEON HF5 Series Ultra Low Energy Membrane Elements AXEON NF3 Series Nanofiltration Membrane Elements AXEON NF4 Series Nanofiltration Membrane Elements AXEON SS Series Membrane Housings AXEON FRP Series Membrane Housings Concentrate Recycle Valve with Flow Meter Goulds Multi Stage Stainless Steel Booster Pump Minitrol IF Computer Controller with Feed Flush S 150 Computer Controller with Feed Flush and Dual TDS S 150 Computer Controller Expander Board Pump Pressure Relief Valve High Pressure Tank Switch Chemical Pump Outlet Blending Valve Permeate Sample Ports Single Wooden Shipping Crate Double Wooden Shipping Crate 2-20

43 Product Specifications Models CT 4000 CT 5000 CT 7000 Design Configuration Single Pass Single Pass Single Pass Feedwater Source TDS <2,000 ppm TDS <2,000 ppm TDS <2,000 ppm Standard Recovery Rate % Recovery with Concentrate Recycle % Up to 75 Up to 75 Up to 75 Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 2.78 / / / Minimum Feed Flow (gpm / lpm) 5.78 / / / Maximum Feed Flow (gpm / lpm) / / / Minimum Concentrate Flow (gpm / lpm) 3.00 / / / Connections Feed (in) 1 FNPT 1 FNPT 1 FNPT Permeate (in) 1 FNPT 1 FNPT 1 FNPT Concentrate (in) 1 FNPT 1 FNPT 1 FNPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1:1 1:1:1 1:1:1:1 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Motor HP Hz (50 Hz) 3450 (2900) 3450 (2900) 3450 (2900) System Electrical Standard Voltage + Amp Draw 220V, 60Hz, 1PH, 8.3A** 220V, 60Hz, 1PH, 8.3A** 220V, 60Hz, 1PH, 8.3A** High Voltage Service + Amp Draw Operating Limits 220V, 50Hz, 1PH, 8.9A** 220V, 60Hz, 3PH, 5.1A** 220V, 50Hz, 3PH, 6.1A** 380V, 50Hz, 3PH, 4.5A** 460V, 60Hz, 3PH, 3.5A** 220V, 50Hz, 1PH, 8.9A** 220V, 60Hz, 3PH, 5.1A** 220V, 50Hz, 3PH, 6.1A** 380V, 50Hz, 3PH, 4.5A** 460V, 60Hz, 3PH, 3.5A** Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow. 220V, 50Hz, 1PH, 8.9A** 220V, 60Hz, 3PH, 5.1A** 220V, 50Hz, 3PH, 6.1A** 380V, 50Hz, 3PH, 4.5A** 460V, 60Hz, 3PH, 3.5A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 30 x 38 x 47 / 76 x 96 x x 38 x 47 / 76 x 96 x x 38 x 47 / 76 x 96 x 119 Approximate Weight (lbs / kg) 235 / / / Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Note 1: All 50Hz systems come standard with AXEON HF4 Series Extra Low Energy Membrane Elements. Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 2000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 150 / 10 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) axeonwater.com MKTF-148-D AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 02/ AXEON Water Technologies 2-21

44

45 DT Series Reverse Osmosis Systems FLEXEON DT Series Reverse Osmosis Systems are designed for high performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and low operating costs. FLEXEON DT Series Reverse Osmosis Systems have been engineered for capacities ranging from 10,000 20,000 gallons per day. These systems feature a space saving design, exceptional pre filtration, quality components and allow for many options and upgrades to suit most applications. DT Reverse Osmosis System Benefits Fully Equipped and Customizable Lightweight Design Compact Space Saving Design Components Easily Accessible Pre Plumbed, Wired and Assembled Factory Tested and Preserved Low Operating Costs Low Maintenance Costs Easy Maintenance and Servicing 1 Year Limited Warranty 2-23

46 Features S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm Controller Permeate TDS Monitoring Feed Flush Front White Powder Coated Aluminum Frame X Micron Filter Bag X100 Bag Filter Housing AXEON 5 Micron Sediment Pre Filter AXEON by Pentek Big Grey Filter Housing Goulds Multi Stage Booster Pump DT Reverse Osmosis System AXEON HF1 Series Low Energy Membranes AXEON PVC Series Membrane Housings AXEON Permeate Flow Meter AXEON Concentrate Flow Meter Feed Low Pressure Switch psi AXEON Composite Feed Solenoid Valve Back AXEON 316L Stainless Steel Concentrate Valve AXEON psi Pump Pressure Gauge AXEON psi Concentrate Pump Pressure Gauge AXEON psi Pre Filter Pressure Gauge Wooden Shipping Crate Options AXEON HF4 Series Extra Low Energy Membranes AXEON HF5 Series Ultra Low Energy Membranes AXEON NF3 Series Nanofiltration Membranes AXEON NF4 Series Nanofiltration Membranes AXEON SS Series Membrane Housings AXEON FRP Series Membrane Housings Concentrate Recycle Valve with Flow Meter Hanna BL pH Controller Goulds Multi Stage Stainless Steel Booster Pump S 150 Computer Controller Expander Board S 150 Computer Controller Feed TDS Monitoring Pump Pressure Relief Valve High Pressure Tank Switch Chemical Pump Outlet Blending Valve Permeate Sample Ports Hanna BL ORP Controller 2-24

47 Product Specifications Models DT DT DT Design Configuration Single Pass Single Pass Single Pass Feedwater Source TDS <2000 ppm TDS <2000 ppm TDS <2000 ppm Standard Recovery Rate % Recovery with Optional Concentrate Recycle % Up to 75 Up to 75 Up to 75 Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 6.94 / / / Minimum Feed Flow (gpm / lpm) / / / Maximum Feed Flow (gpm / lpm) / / / Minimum Concentrate Flow (gpm / lpm) 6.00 / / / Connections Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT Permeate Connection (in) 1 FNPT 1 FNPT 1 FNPT Concentrate Connection (in) 1 FNPT 1 FNPT 1 FNPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 2:2:2 2:2:2:2 2:2:2:2:2 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Motor HP (50 Hz) 3450 (2900) 3450 (2900) 3450 (2900) System Electrical Standard Voltage + Amp Draw 220V, 60Hz, 1PH, 16.9A** 220V, 60Hz, 1PH, 16.9A** 220V, 60Hz, 3PH, 14.7A** High Voltage Service + Amp Draw Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Note 1: All 50Hz systems come standard with AXEON HF4 Series Extra Low Energy Membrane Elements. Operating Limits 220V, 50Hz, 1PH, 17.0A** 220V, 60Hz, 3PH, 8.1A** 220V, 50Hz, 3PH, 9.1A** 380V, 50Hz, 3PH, 5.3A** 460V, 60Hz, 3PH, 4.6A** 220V, 50Hz, 1PH, 17.0A** 220V, 60Hz, 3PH, 8.1A** 220V, 50Hz, 3PH, 9.1A** 380V, 50Hz, 3PH, 5.3A** 460V, 60Hz, 3PH, 4.6A** 220V, 50Hz, 3PH, 15.9A** 380V, 50Hz, 3PH, 8.5A** 460V, 60Hz, 3PH, 7.5A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 49 x 33 x 54 / 125 x 84 x x 33 x 54 / 140 x 84 x x 33 x 54 / 155 x 84 x 137 Approximate Weight (lbs / kg) 350 / / / 204 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 2000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 150 / 10 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com 2-25 MKTF-186-D AXEON and FLEXEON are registered trademarks of AXEON Water Technologies. 02/ AXEON Water Technologies

48 HT Series Wall Mount Reverse Osmosis Systems FLEXEON HT Series Wall Mount Reverse Osmosis Systems are designed for filter and membrane servicing and are available in five models ranging in production capacities from 250 to 2,000 gallons per day. The HT Series models are equipped with our unique EZMount two piece wall mounting system for easy installation. An optional mobile stand is also available to convert any of the HT Series models into floor standing systems. Features n AXEON HF1 Series Low Energy Membranes n AXEON PVC Series Membrane Housings n AXEON 5 Micron Sediment Pre Filter n AXEON by Pentek 20 Slim Line Cartridge Housing n AXEON Permeate and Concentrate Flow Meters n AXEON psi Glycerin Filled Pre Filter Pressure Gauge n AXEON psi Glycerin Filled Pump Pressure Gauge n Manual On and Off Control Switch n Feed Low Pressure Switch FLEXEON HT Series Wall Mount Reverse Osmosis Systems n AXEON by GC Feed Solenoid Valve n AXEON 316L Stainless Steel Concentrate Valve n Fluid O Tech Low Lead Brass Rotary Vane High Pressure Pump n ODP High Efficiency Carbonator Motor n John Guest Push/Pull Fittings with Locking Safety Clips n White Powder Coated Aluminum Frame Product Specifications Models HT 250 HT 500 HT 1000 HT 1500 HT 2000 Design Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Membranes Membrane Quantity Membrane Size Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 48 X 49 X 12 / 122 X 124 X X 49 X 12 / 122 X 124 X X 49 X 12 / 122 X 124 X X 49 X 12 / 122 X 124 X X 49 X 12 / 122 X 124 X 30 Approximate Weight (lbs / kg) 60 / / / / / 61.2 * Does not include operating space requirements axeonwater.com 2-26 MKTF-195-A AXEON and FLEXEON are registered trademarks of AXEON Water Technologies 11/ AXEON Water Technologies

49 JT Series Wall Mount Reverse Osmosis Systems FLEXEON JT Series Wall Mount Reverse Osmosis Systems offer high production capacities and are fully equipped with a computer controller, TDS monitor, multi stage booster pump, low energy membranes and a sediment filter mounted on a corrosion resistant, powder coated aluminum frame. FLEXEON JT Series Wall Mount Reverse Osmosis Systems models are available in capacities of 2,000 and 4,000 gallons per day and feature the EZMount two piece wall mounting system for easy installation. An optional mobile stand is also available to convert any of the models into floor standing units. Features Minitrol Computer Controller Multi Color LED Indicator Status Light Pre Treatment Lockout Tank Level Input Low Pressure Monitoring and Alarm AXEON HF1 Series Low Energy Membranes AXEON PVC Series Membrane Housings AXEON 5 Micron Sediment Pre Filter AXEON by Pentek Big Grey Cartridge Housing AXEON Permeate and Concentrate Flow Meters AXEON psi Pre Filter Pressure Gauge AXEON psi Post Filter Pressure Gauge FLEXEON JT Series Wall Mount Reverse Osmosis System Shown with Concentrate Recycle Option AXEON psi Pump Pressure Gauge AXEON psi Concentrate Pressure Gauge Feed Low Pressure Switch AXEON by GC Feed Solenoid Valve AXEON 316L Stainless Steel Concentrate Valve Goulds Multi Stage Booster Pump John Guest Push/Pull Fittings with Locking Safety Clips White Powder Coated Aluminum Frame Product Specifications Models JT 2000 JT 4000 Design Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Membranes Membrane Quantity 1 2 Membrane Size Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 12 X 48 X 49 / 30.5 X X X 48 X 49 / 30.5 X X Approximate Weight (lbs / kg) 150 / / 79.4 * Does not include operating space requirements axeonwater.com MKTF-196-A AXEON and FLEXEON are registered trademarks of AXEON Water Technologies 11/ AXEON Water Technologies 2-27

50 ST Series Reverse Osmosis Systems The FLEXEON ST Series Reverse Osmosis System is a state of the art, versatile system for treating tap water supplies with a production flow rate of 500 gallons per day utilizing minimal energy consumption with low maintenance and operational costs. The design of this system is perfectly suited for a wide range of applications including use in coffee and tea production, cleaning and sanitizing, misting and more. The FLEXEON ST Series Reverse Osmosis System is uniquely designed to rotate 360 on top of a 40 gallon steel reverse osmosis storage tank that is designed to store and deliver water under pressure between pump cycles. The system features AXEON HF5 Series Ultra Low Energy Membranes, AXEON by Pentek Filter Housings, AXEON gauges, flow meters, cartridges and needle valves with flow meter. Features Concentrate Flow Meter with Integrated Stainless Steel AXEON ST 500 Reverse Osmosis System Feed and Permeate TDS Meters Needle Valve System Bypass Valve System Blend Valve Feed Low Pressure Switch Permeate High Pressure Switch Permeate Pressure Gauge Pump and Concentrate Pressure Gauges AXEON HF5 Series Extra Low Energy Membranes AXEON 4.5 x 20 5 Micron Sediment Pre Filter Built-in Internal Permeate Flush Permeate Sample Valve Feed Sample Valve AXEON by ASCO Composite Feed Solenoid Valve Permeate Flow Meter Pre Filter In/Out Gauges White Powder Coated Aluminum Frame 40 Gallon Steel Pressure Tank AXEON Stainless Steel Series Housings AXEON 2.5 x Micron Carbon Block Pre Filter AXEON 2.5 x Micron Carbon Block Post Filter Stainless Steel Rotary Vane Pump 2-28

51 ST Series Reverse Osmosis Systems Product Specifications Model ST 500 Design Configuration Feedwater Source Single Pass TDS <1000 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % 98.5 Permeate Flow (gpm / lpm) 0.35 / 1.30 Minimum Feed Flow (gpm / lpm) 1.35 / 5.10 Maximum Feed Flow (gpm / lpm) 6.00 / Minimum Concentrate Flow (gpm / lpm) 1.00 / 3.70 Connections Feed Connection (in) Permeate Connection (in) Concentrate Connection (in) Membranes Membrane(s) Per Vessel 1 Membrane Quantity 2 1/2 QC 1/2 QC 3/8 QC Membrane Size 2521 Vessels Vessel Array 1:1 Vessel Quantity 2 Standard Pump Pump Type Stainless Steel Rotary Vane 411 Motor HP 1/3 60Hz 1725 System Electrical Standard Voltage + Amp Draw High Voltage Service + Amp Draw Systems Dimensions 120VAC / 1PH / 60Hz / 6.6A** 220VAC / 1PH / 60Hz / 3.2A** Approximate Dimensions* L x W x H (in / cm) 21 x 21 x 68 / 53.3 x 53.3 x Approximate Weight (lbs / kg) 170 / 77 Dry Weight Test Parameters: 550 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 80 psi / 5.52 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) Up to 1000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 150 / 10 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-389- AXEON and FLEXEON are registered trademarks of AXEON Water Technologies 10/ AXEON Water Technologies2-29

52

53

54

55 R2 Series Reverse Osmosis Systems AXEON R2 Series Reverse Osmosis Systems are designed for durability and superior performance and are well suited for treating well water and surface water containing dissolved solids up to 10,000 ppm. The R2 Series is specifically designed with a compact frame to fit into small areas such as utility rooms. AXEON R2 Series Reverse Osmosis Systems have been engineered for capacities ranging from 1,500 to 9,000 gallons per day. These systems include a computer processor with standard control functions for dual TDS monitoring, low pressure monitoring with alarm, pre treatment lockout, feed flush and tank level input. These models feature high quality components such as a stainless steel multi stage high pressure pump, low energy membrane elements, membrane housings rated at 450 psi and a cartridge housing with a 5 micron sediment pre filter. Options available for the R2 Series include permeate divert, variable frequency drive, a chemical injection system and a clean in place system. R Reverse Osmosis System Benefits Fully Equipped and Customizable Expandable and Skid Mounted Pre Plumbed, Wired and Assembled Individually Tested and Preserved Easy Maintenance and Servicing 1 Year Limited Warranty Decreased Size of Dimensional Footprint Components Easily Accessible Low Operation and Maintenance Costs 3-3

56 Features S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input High Pressure Monitoring with Alarm Low Pressure Monitoring with Alarm Dual TDS Monitoring Feed Flush AXEON Permeate and Concentrate Flow Meters AXEON Pre Filter psi Panel Mounted Glycerin Filled Gauges AXEON Post Filter psi Panel Mounted Glycerin Filled Gauges AXEON psi Glycerin Filled Pump Discharge and Concentrate Pressure Gauges AXEON 5 Micron Sediment Pre Filter AXEON by Pentek Single O Ring Heavy Duty Filter Housing Filmtec LCLE Low Energy Membrane Elements AXEON FRP Series Membrane Housings 450 psi Permeate Sample Ports Vertical Multi Stage Stainless Steel Booster Pump Plastomatic Feed Solenoid Valve Feed Low Pressure Switch Pump High Pressure Switch Clean in Place (CIP) Ports R Reverse Osmosis System Victaulic Style Fittings Permeate Sample Ports High Pressure Stainless Steel Tubing and Fittings White Powder Coated Aluminum Frame Options and Upgrades S 150 Expander Board Variable Frequency Drive (VFD) Filmtec LCHR Membrane Elements Pump Pressure Relief Valve Blending Valve Permeate Divert Valve Permeate Flush Chemical Pump Outlet Hanna BL ph Controller Hanna BL ORP Controller High Pressure Tank Switch Caster Wheels Wooden Shipping Crate AXEON Naming Matrix R R-SERIES MODEL R2 Brackish Water Model HOUSING QUANTITY DESIGNATION 1 1 Vessel 2 2 Vessel 3 3 Vessel 4 4 Vessel 5 5 Vessel 6 6 Vessel MEMBRANE QUANTITY PER HOUSING 1 1 Membrane 4.0 INCH MEMBRANE DIAMETER 3-4

57 Notes: 1. All dimensions are given in inches. 2. R AXEON model shown WATER INLET SOV 20 FILTER HOUSING PI x2 5 MICRON SEDIMENT LPS TDS REVERSE OSMOSIS PUMP HPS PI FILMTEC LCLE MEMBRANES CV PI CONCENTRATE VALVE FM CV TDS FLOW METER CONCENTRATE DRAIN FM FLOW METER PERMEATE POINT OF USE Array Specifications Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity R R : R :1: R :1:1: R :1:1:1: R :1:1:1:1:

58 R2 Series Reverse Osmosis Systems Product Specifications Models R R R R R R Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater Source TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 1.04 / / / / / / Minimum Feed Flow (gpm / lpm) 4.04 / / / / / / Maximum Feed Flow (gpm / lpm) / / / / / / Minimum Concentrate Flow (gpm / lpm) 3.00 / / / / / / Connections Feed (in) 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Permeate (in) 3/4 FNPT 3/4 FNPT 3/4 FNPT 1 FNPT 1 FNPT 1 FNPT Concentrate (in) 3/4 FNPT 3/4 FNPT 3/4 FNPT 1 FNPT 1 FNPT 1 FNPT CIP (in) 3/4 FNPT 3/4 FNPT 3/4 FNPT 3/4 FNPT 3/4 FNPT 3/4 FNPT Membranes Membrane Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1 1:1 1:1:1 1:1:1:1 1:1:1:1:1 1:1:1:1:1:1 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Motor HP Hz (50 Hz) 3450 (2900) 3450 (2900) 3450 (2900) 3450 (2900) 3450 (2900) 3450 (2900) System Electrical Standard Voltage + Amp Draw 220V, 60Hz, 1PH, 14.5A** 220V, 60Hz, 1PH, 14.5A** 220V, 60Hz, 1PH, 14.5A** 220V, 60Hz, 3PH, 14.2A** 220V, 60Hz, 3PH, 14.2A** 220V, 60Hz, 3PH, 14.2A** High Voltage Service + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) Operating Limits 220V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** 27 x 26 x 61 / 69 x 66 x V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** 27 x 26 x 61 / 69 x 66 x V, 50Hz, 1PH, 17.4A** 220V, 50Hz, 3PH, 10.6A** 220V, 50Hz, 3PH, 16.1A** 220V, 50Hz, 3PH, 16.1A** 220V, 50Hz, 3PH, 16.1A** 220V, 60Hz, 3PH, 9A** 460V, 60Hz, 3PH, 5A** 460V, 60Hz, 3PH, 7A** 460V, 60Hz, 3PH, 7A** 460V, 60Hz, 3PH, 7A** 30 x 26 x 61 / 75 x 66 x x 26 x 61 / 80 x 66 x x 26 x 61 / 80 x 66 x 155 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow. 37 x 26 x 61 / 94 x 66 x 155 Approximate Weight (lbs / kg) 560 / / / / / / 320 Test Parameters: 10,000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum TDS (ppm) 10,000 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum Hardness (gpg) <1 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum ph (Continuous) 11 Maximum Feed Pressure (psi / bar) 85 / 6 Minimum ph (Continuous) 2 Minimum Feed Pressure (psi / bar) 45 / 3 Maximum ph (Cleaning 30 Minutes) 13 Maximum Operating Pressure (psi / bar) 400 / 28 Minimum ph (Cleaning 30 Minutes) 1 Maximum Feed Silt Density Index (SDI) <3 Maximum Turbidity NTU < axeonwater.com 3-6 MKTF-109-B AXEON is a registered trademark of AXEON Water Technologies. 10/ AXEON Water Technologies

59 M2 Series Reverse Osmosis Systems M2 Series Reverse Osmosis Systems are a line of high capacity systems with flows ranging from 12,000 to 36,000 gallons per day. These systems are ideal for removing the salt content in well water and surface water for use in commercial and light industrial applications. Using an efficient high pressure pump, the M2 Series systems are engineered for treating brackish water with levels of 10,000 ppm. M2 Series Reverse Osmosis Systems feature a M computer controller that has dual Reverse Osmosis System TDS monitoring, low pressure monitoring and alarm, pretreatment lockout, and feed flush and tank level input while larger models include an additional digital flow monitor. All models include low energy reverse osmosis membrane elements, motorized feed valve, permeate sample ports and a bag filter housing with a 5 Micron filter bag. Some options available for the M2 Series include permeate flush, permeate divert, variable frequency drive, chemical injection system and clean in place system. Benefits Fully Equipped and Customizable Skid Mounted Components Easily Accessible Pre Plumbed, Wired and Assembled Individually Tested and Preserved Low Operation and Maintenance Costs Easy Maintenance and Servicing 20% Less Energy 1 Year Limited Warranty 3-7

60 Features Models: M2 4240, M2 6240, M S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low and High Pressure Monitoring and Alarm Dual TDS Monitoring Hour Meter Feed Flush Rejection Percentage Models: M , M S 200 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low and High Pressure Monitoring and Alarm Hour Meter Dual TDS Monitoring Feed Flush Digital Flow Meters (2) Rejection Percentage M Reverse Osmosis System Recovery Percentage AXEON Permeate and Concentrate Flow Meters* Stainless Steel Concentrate Globe Valve AXEON Pre Filter psi Panel Mounted Glycerin Filled Gauges AXEON Pump Discharge psi Panel Mounted Glycerin Filled Stainless Steel Gauges AXEON 5 Micron Filter Bag AXEON Bag Filter Housing with Stainless Steel Stand Filmtec LCLE Membrane Elements AXEON FRP Series Membrane Housings 450 psi Vertical Multi Stage 316L Stainless Steel Booster Pump George Fisher Motorized Valve Feed Low Pressure Switch Pump High Pressure Switch Clean In Place (CIP) Ports Victaulic Style Fittings Permeate Sample Ports High Pressure Stainless Steel Piping and Fittings White Powder Coated Aluminum Frame Wooden Shipping Crate Options and Upgrades S 150 Expander Board* S 200 Computer Controller* S 200 ph Monitoring* S 200 ORP Monitoring* Variable Frequency Drive** Filmtec LCHR Membrane Elements High Pressure Tank Switch Hanna BL ph Controller* Hanna BL ORP Controller* Chemical Pump Outlet Blending Valve Permeate Divert Valve Pump Pressure Relief Valve** Caster Wheels AXEON Naming Matrix M M-SERIES MODEL M2 Brackish Water Model HOUSING QUANTITY DESIGNATION 4 4 Vessel 6 6 Vessel 8 8 Vessel Vessel Vessel MEMBRANE QUANTITY PER HOUSING 2 2 Membranes 4.0 INCH MEMBRANE DIAMETER * Only available on the following models: M1 4240, M1 6240, M ** Standard for all 50Hz Systems 3-8

61 64 100" Notes: All dimensions are given in inches. 2. Model M AXEON model shown. Array Specifications Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity M : M :2: M :3: M :3:2: M :3:2:2:

62 M2 Series Reverse Osmosis Systems Operating Limits Product Specifications Models M M M M M Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater Source TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm TDS <10,000 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow* (gpm / lpm) 8.30 / / / / / Minimum Feed Flow (gpm / lpm) / / / / / Maximum Feed Flow (gpm / lpm) 28 / / / / / 159 Minimum Concentrate Flow (gpm / lpm) 6 / 23 6 / 23 6 / 23 6 / 23 6 / 23 Connections Feed FNPT (in) Permeate FNPT (in) Concentrate FNPT (in) CIP FNPT (in) Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 2:2 2:2:2 3:3:2 3:3:2:2 3:3:2:2:2 Vessel Quantity Pumps Pump Type Multi Stage Multi Stage Multi Stage Multi Stage Multi Stage Motor HP Hz Hz VFD at 60Hz VFD at 60Hz VFD at 60Hz VFD at 60Hz VFD at 60Hz System Electrical Standard Voltage + Amp Draw 220V, 60Hz, 3PH, 19.2A** 220V, 60Hz, 3PH, 9A** 220V, 60Hz, 3PH, 13.6A** 220V, 60Hz, 3Ph, 19.2A** 220V, 60Hz, 3Ph, 19.2A** 220V, 50Hz, 3PH, 22.9A** 220V, 50Hz, 3PH, 22.9A** 220V, 50Hz, 3PH, 30.9A** 220V, 50Hz, 3PH, 30.9A** 220V, 50Hz, 3PH, 45A** High Voltage Service + Amp Draw 460V, 60Hz, 3PH, 9.7A** 460V, 60Hz, 3PH, 9.7A** 460V, 60Hz, 3PH, 12.9A** 460V, 60Hz, 3PH, 12.9A** 460V, 60Hz, 3PH, 18.5A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 31 x 100 x 64 / x 2540 x x 100 x 64 / x 2540 x x 100 x 64 / x 2540 x x 100 x 64 / x 2540 x 1626 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow. 31 x 100 x 64 / x 2540 x 1626 Weight lb. (kg) 1260 / / / / / 748 Test Parameters: 10,000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) 1 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum TDS (ppm) 10,000 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Continuous) 11 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Continuous) 2 Maximum Operating Pressure (psi / bar) 400 / 28 Maximum ph (Cleaning 30 Minutes) 13 Maximum Feed Silt Density Index (SDI) <3 Minimum ph (Cleaning 30 Minutes) axeonwater.com 3-10 MKTF-116-D AXEON is a registered trademark of AXEON Water Technologies. 06/ AXEON Water Technologies

63 X2 Series Industrial Reverse Osmosis Systems AXEON X2 Series Reverse Osmosis Systems are engineered to treat demanding feedwater conditions such as high content of dissolved solids. Designed for robust applications requiring high pressures, the AXEON X2 Series Reverse Osmosis Systems are ideally suited for brackish water. X Industrial Reverse Osmosis System X2 Series models range in capacity from 21 to 126 gallons per minute (30,240 to 181,440 gallons per day). Using high efficiency 8 inch reverse osmosis elements with 10% greater membrane surface area, AXEON X2 Series Systems are able to significantly reduce TDS in both municipal and well water sources while producing higher volumes of permeate water. Low energy brackish water membranes are available for cold temperature applications and high rejection brackish water membranes are available for high TDS applications. The AXEON X2 Series Systems feature a pre programmed computer controller, motorized feed valve, TDS probes and panel mounted pressure and flow instrumentation. The larger models include digital flow indicators and VFD motor controls. Stainless steel components are used for the vertical multistage pump, cartridge filter housing, high pressure piping and valves, and the side ports on the FRP membrane housings. 3-11

64 Standard Features 8 inch Low Energy Membrane Elements (440 SF) 8 inch Fiberglass Membrane Housings with 316L Stainless Steel Side Ports (450 psi) 5 Micron Sediment Filters Multi Cartridge 316L Stainless Steel Cartridge Housing Vertical 316L Stainless Steel Multi Stage Pump Low and High Pressure Shut Off Switches S 150 Pre Programmed Computer Controller* S 200 Pre Programmed Computer Controller with VFD (Variable Frequency Drive)** Permeate and Concentrate Rotameters* Permeate and Concentrate Digital Paddlewheel Sensors** Options and Upgrades S 200 Computer Controller*** VFD*** Programmable Logic Controller (PLC) with Touch Screen Permeate and Concentrate Digital Paddlewheel Sensors*** PVC Feed Motorized Ball Valve*** PVC Permeate Divert Motorized Ball Valve Permeate Flush ph Sensor X Industrial Reverse Osmosis System Feed and Permeate TDS Monitoring Pre and Post Filter 316L Stainless Steel Pressure Gauges Pump Pressure and Concentrate 316L Stainless Steel Pressure Gauges Composite Feed Solenoid Valve* PVC Feed Motorized Ball Valve** 316L Stainless Steel Globe Throttling Valve 316L Stainless Steel Globe Concentrate Valve ORP Sensor Clean In Place (CIP) Skid Mounted System Chemical Feed System Voltage Options: 220VAC 3PH 60Hz, 220VAC 3PH 50Hz, 380VAC 3PH 50Hz Powder Coated Carbon Steel Frame Sch80 Low Pressure PVC Piping Stainless Steel High Pressure 316L Piping Clean In Place (CIP) Ports with Valves Permeate Sample Valves Chemical Feed Ports Chemical Feed Power Outlet 460 VAC 3PH 60Hz * Standard on Models X2 2280, X2 3280, X2 4280, X ** Standard on Models X2 3480, X2 4480, X2 5480, X *** Option available for Models X2 2280, X2 3280, X2 4280, X Standard on larger models. 3-12

65 Notes: 1. All dimensions are given in inches. 2. Dimensions given for X through X (X pictured) Notes: 1. All dimensions are given in inches. 2. Dimensions given for X through X (X pictured) 3-13

66 X2 Series Reverse Osmosis Systems Product Specifications Models X X X X X X X X Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater TDS max (ppm) 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000 Standard Recovery % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow Rate (gpm / lpm) Minimum Concentrate Flow Rate (gpm / lpm) Connections / / / / / / / Design Temperature ( F / C) 77 / 25 Maximum SDI Rating (SDI) < 3 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4.4 Maximum Hardness (gpg) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum ph (Continuous) 11 Minimum Ambient Temperature ( F / C) 40 / 4.4 Minimum ph (Continuous) 2 Maximum Feed Pressure (psi / bar) 85 / 6 Maximum ph (Cleaning 30 Minutes) 13 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Cleaning 30 Minutes) 1 Maximum Piping Pressure (psi / bar) 400 / 28 Maximum Turbidity (NTU) < / / / / / / / / / Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT 3 FNPT 3 FNPT Permeate Connection (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 1/2 FNPT 2 1/2 FNPT 3 FNPT 3 FNPT Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT Clean in Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1:1 1:1:1 2:1:1 2:1:1:1 2:1 2:1:1 3:1:1 3:2:1 Vessel Quantity Pumps Pump Type Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Vertical Multi Stage Centrifugal Pump Motor HP / KW 15 / / / / / / / / 37 System Electrical Standard Voltage + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) Approximate Weight (lbs / kg) 460V, 60Hz, 3PH, 19A** 112 x 35 x 74 / 284 x 89 x V, 60Hz, 3PH, 19A** 112 x 35 x 74 / 284 x 89 x V, 60Hz, 3PH, 31A** 112 x 35 x 74 / 284 x 89 x V, 60Hz, 3PH, 31A** 112 x 35 x 84 / 284 x 89 x V, 60Hz, 3PH, 31A** 460V, 60Hz, 3PH, 48.5A** 460V, 60Hz, 3PH, 48.5A** 194 x 41 x 78 / 194 x 41 x 78 / 194 x 41 x 78 / 493 x 104 x x 104 x x 104 x V, 60Hz, 3PH, 58.5A** 194 x 41 x 84 / 493 x 104 x / / / / / / / / 2560 Test Parameters: 7000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / 24 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-113-E AXEON is a registered trademark of AXEON Water Technologies. 08/ AXEON Water Technologies

67

68 T3 Series Reverse Osmosis Systems AXEON T3 Series Reverse Osmosis Systems are designed and manufactured for seawater applications requiring capacities of 3,000 to 7,000 gallons per day. AXEON T3 Series Reverse Osmosis Systems are equipped with premium components, which include a 316L plunger type pump for high performance and corrosion resistance, a high grade corrosion resistant aluminum frame, a programmable computer controller with many built in features and fiberglass membrane housings for durability. Features T Reverse Osmosis System S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Low and High Pressure Monitoring and Alarm Permeate TDS Monitoring Hour Meter Feed Flush High Rejection Sea Water Membranes AXEON FRP Series Membrane Housings AXEON 5 Micron Sediment Pre Filter AXEON by Pentek Single O Ring Cartridge Housing Permeate and Concentrate Flow Meters GF Motorized Valve PVC psi Pre Filter Out Pressure Gauge psi Concentrate Pressure Gauge AXEON 316L Stainless Steel Needle Valve SS Feed Low Pressure Switch SS Pump High Pressure Switch Pressure Relief Valve Pressure Regulator CAT 316L High Pressure Pump TEFC Motor with Thermal Motor Protection White Powder Coated Aluminum Frame High Pressure 316L Stainless Steel Tubing and Fittings High Pressure Hose with Reusable SS Fittings 4-2

69 T3 Series Reverse Osmosis Systems Test Parameters: 35,000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 950 psi / 65.5 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Product Specifications Models T T T Design Configuration Single Pass Single Pass Single Pass Feedwater Source <45,000 ppm <45,000 ppm <45,000 ppm System Recovery with Recycle % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow Rate (gpm / lpm) 2.70 / / / Concentrate Flow Rate (minimum) (gpm / lpm) 4.00 / / / Connections Feed Connection (in) 1 FNPT 1 FNPT 1 FNPT Permeate Connection (in) 1 FNPT 1 FNPT 1 FNPT Concentrate Connection (in) 1 FNPT 1 FNPT 1 FNPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1:1:1:1 1:1:1:1:1 1:1:1:1:1:1 Vessel Quantity Pumps Pump Type Piston Piston Piston Motor HP RPM at 60Hz System Electrical Controller S 150 S 150 S 150 High Voltage Service + Amp Draw 220V, 3PH, 60Hz, 20A** 220V, 3PH, 60Hz, 20A** 220V, 3PH, 60Hz, 20A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 60 x 26 x 48.5 / x 66.0 x x 26 x 48.5 / x 66.0 x x 26 x 48.5 / x 66.0 x Approximate Weight (lbs / kg) 270 / / / Operating Limits Design Temperature ( F / C) 77 / 25 Maximum Turbidity (NTU) 1 Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum TDS (ppm) < 45,000 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum Hardness (gpg) 1 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum ph (Continuous) 11 Maximum Feed Pressure (psi / bar) 65 / 4 Minimum ph (Continuous) 2 Minimum Feed Pressure (psi / bar) 45 / 3 Maximum ph (Cleaning 30 Minutes) 13 Maximum Operating Pressure (psi / bar) 1,000 / 69 Minimum ph (Cleaning 30 Minutes) 1 Maximum Feed Silt Density Index (SDI) <3 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-315-B AXEON is a registered trademark of AXEON Water Technologies. 11/ AXEON Water Technologies 4-3

70

71 S3 Series Reverse Osmosis Systems AXEON S3 Series Reverse Osmosis Systems are engineered and manufactured for seawater applications specifically tailored for capacities ranging from 600 to 2,200 gallons per day. The S3 Series Reverse Osmosis Systems feature a unique and innovative compact design that allows for easy installation in any size area. S Reverse Osmosis System The S3 Series is also equipped with premium components, which include a 316L SS plunger type pump for high performance, a high grade corrosion resistant aluminum frame, a programmable computer controller with many built in features and fiberglass membrane housings for durability. Benefits Fully Equipped and Customizable High Quality Components Individually Tested and Preserved Easy Maintenance and Servicing Pre Plumbed, Wired and Assembled 1 Year Limited Warranty Low Operating and Maintenance Costs 4-5

72 Features S 150 Computer Controller LCD Backlit Display Pre Treatment Lockout Tank Level Input Pressure Monitoring and Alarm TDS Monitoring Hour Meter Feed Flush High Rejection Seawater Membranes AXEON FRP Series Membrane Housings AXEON 5 Micron Sediment Pre Filter AXEON by Pentek Single O Ring Cartridge Housing Permeate and Concentrate Flow Meters S Reverse Osmosis System psi 316L SS Glycerin Filled Filter In Pressure Gauge psi 316L SS Glycerin Filled Pre Filter Out Pressure Gauge psi 316L SS Glycerin Filled Concentrate Pressure Gauge Plast O Matic Feed Solenoid Valve AXEON 316L Stainless Steel Needle Valve 316L SS Feed Low Pressure Switch 316L SS High Pressure Pump Switch CAT 316L High Pressure Pump TEFC Motor with Thermal Motor Protection Chemical Pump Outlet Powder Coated Aluminum Frame High Pressure 316L Stainless Steel Tubing and Fittings High Pressure Hose with Reusable SS Fittings Options and Upgrades Booster Pump High Pressure Tank Switch Permeate Divert Valve Fresh Water Flush Ultraviolet Light Wooden Shipping Crate 4-6

73 Notes: 1. All dimensions are given in inches. S S AXEON model shown. S S S Array Specifications Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity S S : S :1: S :1:1:

74 S3 Series Reverse Osmosis Systems Product Specifications Models S S S S Design Configuration Single Pass Single Pass Single Pass Single Pass Feedwater Source TDS <35,000 ppm TDS <35,000 ppm TDS <35,000 ppm TDS <35,000 ppm Standard Recovery Rate % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow (gpm / lpm) 0.41 / / / / 5.75 Minimum Feed Flow (gpm / lpm) 4.20 / / / / Connections Feed FNPT (in) 1/2 1/2 1/2 1/2 Permeate Tubing (in) 3/8 3/8 3/8 3/8 Concentrate Tubing (in) 3/8 3/8 3/8 3/8 Membranes Membrane Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1 1:1 1:1:1 1:1:1:1 Vessel Quantity Pumps Pump Type Plunger Plunger Plunger Plunger Motor (HP / kw) 2.50 / / / / Hz (50 Hz) 1725 / / / / 1450 System Electrical Standard Voltage + Amp Draw 220VAC, 1PH, 11.9A** 220VAC, 1PH, 11.9A** 220VAC, 1PH, 11.9A** 220VAC, 1PH, 11.9A** Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 48 X 24 X 18.5 / 122 X 61 X X 24 X 18.5 / 122 X 61 X X 24 X 18.5 / 122 X 61 X X 24 X 18.5 / 122 X 61 X 47 Approximate Weight (lbs / kg) 145 / / / / Test Parameters: 35,000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 45 psi / 3.1 bar Feed Pressure, 850 psi / bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Turbidity (NTU) <1 Minimum Feed Temperature ( F / C) 41 / 5 Maximum Free Chlorine (ppm) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum Hardness (gpg) 0 Minimum Ambient Temperature ( F / C) 40 / 4 Maximum ph (Continuous) 11 Maximum Feed Pressure (psi / bar) 60 / 4 Minimum ph (Continuous) 2 Minimum Feed Pressure (psi / bar) 15 / 1 Maximum ph (Cleaning 30 Minutes) 13 Maximum Operating Pressure (psi / bar) 1000 / 69 Minimum ph (Cleaning 30 Minutes) 1 Maximum Feed Silt Density Index (SDI) <3 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com 4-8 MKTF-108-D AXEON is a registered trademark of AXEON Water Technologies. 07/ AXEON Water Technologies

75 X3 Series Industrial Reverse Osmosis Systems X3 Series Reverse Osmosis Systems are engineered for seawater desalination and other high total dissolved solids (TDS) applications requiring high pressure pumps. The X3 Series Reverse Osmosis Systems are rated to handle total dissolved solids as high as 45,000. The X3 Series Reverse Osmosis Systems range in capacity from 5.6 to 27.8 gallons per minute X Industrial Reverse Osmosis System (8,000 to 40,000 gallons per day) utilize a clean design that allows for convenient installation, user friendly operation. Featuring robust components for enhanced performance, the X3 Series Reverse Osmosis Systems include a duplex stainless steel axial piston pump, high pressure hoses, stainless steel valving and FRP membrane housings with duplex stainless steel side ports. 4-9

76 Standard Features 8 inch Low Energy Seawater Membrane Elements 8 inch Fiberglass Membrane Housings with Duplex Stainless Steel Side Ports (1000 psi) 2 Stage Glass Reinforced, Polypropylene, Non Metallic Pre Filtration Housings 5 Micron Sediment Pre Filter (Stage 1) 1 Micron Sediment Pre Filter (Stage 2) Duplex Stainless Steel Axial Piston Pump Low and High Pressure Shut Off Switch Pump Pressure Relief Valve S 150 Pre Programmed Computer Controller with Soft Start Permeate and Concentrate Rotameters Permeate TDS Monitoring Pre and Post Filter 316L Stainless Steel Pressure Gauges X Industrial Reverse Osmosis System Pump and Concentrate 316L Stainless Steel Pressure Gauges PVC Feed Motorized Ball Valve 316L Stainless Steel Needle Concentrate Valve Epoxy Powder Coated Carbon Steel Frame Sch80 Low Pressure PVC Piping Electroplated 316L Sch80 Stainless Steel Piping Nitrile High Pressure Hose with Duplex Stainless Steel Connections Clean In Place (CIP) Ports with Valves Permeate Sample Ports Chemical Feed Port Chemical Feed Power Outlet Composite Permeate Flush Solenoid Valve PVC Permeate Divert Motorized Ball Valve 460VAC 3PH 60Hz Options and Upgrades S 200 Computer Controller Permeate and Concentrate Digital Paddlewheel Sensors VFD (Variable Frequency Drive) Programmable Logic Controller (PLC) with Touch Screen ph Sensor ORP Sensor Clean In Place Skid Mounted System Chemical Feed System 8 inch Low Energy Seawater Membrane Elements (440 SF) Voltage Options: 220VAC 3PH 60Hz, 220VAC 3PH 50Hz, 380VAC 3PH 50Hz 4-10

77 144" Notes: 41" 1. All dimensions are given in inches. 2. Dimensions given for X through X (X pictured) " " 4-11

78 X3 Series Reverse Osmosis Systems Product Specifications Models X X X X X Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Feedwater TDS max (ppm) 38,000 38,000 38,000 38,000 38,000 Standard Recovery % Rejection and Flow Rates Nominal Salt Rejection % Permeate Flow Rate (gpm / lpm) 5.60 / / / / / Minimum Concentrate Flow Rate (gpm / lpm) 14 / / / / / 106 Connections Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT Permeate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT Clean in Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Membranes Membrane(s) Per Vessel Membrane Quantity Membrane Size Vessels Vessel Array 1 1:1 1:1:1 2:1:1 2:1:1:1 Vessel Quantity Pumps Pump Type Axial Piston Axial Piston Axial Piston Axial Piston Axial Piston Motor HP / KW 20 / / / / / 30 System Electrical Standard Voltage + Amp Draw Systems Dimensions Approximate Dimensions* L x W x H (in / cm) 460V, 60Hz, 3PH, 25.5A 144 x 41 x 75 / 366 x 104 x V, 60Hz, 3PH, 25.5A 144 x 41 x 75 / 366 x 104 x V, 60Hz, 3PH, 31A** 144 x 41 x 75 / 366 x 104 x V, 60Hz, 3PH, 48.5A 144 x 41 x 75 / 366 x 104 x 190 Test Parameters: 35,000 TDS Filtered (5 Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 950 / 65.5 psi bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 ph. Data taken after 60 minutes of operation. * Does not include operating space requirements. ** Varies with motor manufacturer. Design Temperature ( F / C) 77 / 25 Maximum SDI Rating (SDI) < 3 460V, 60Hz, 3PH, 48.5A 144 x 41 x 85 / 366 x 104 x 216 Approximate Weight (lbs / kg) 2230 / / / / / 1920 Operating Limits Maximum Feed Temperature ( F / C) 85 / 29 Maximum Free Chlorine (ppm) 0 Minimum Feed Temperature ( F / C) 40 / 4 Maximum Hardness (gpg) 0 Maximum Ambient Temperature ( F / C) 120 / 49 Maximum ph (Continuous) 11 Minimum Ambient Temperature ( F / C) 40 / 4 Minimum ph (Continuous) 2 Maximum Feed Pressure (psi / bar) 72.5 / 5 Maximum ph (Cleaning 30 Minutes) 12 Minimum Feed Pressure (psi / bar) 45 / 3 Minimum ph (Cleaning 30 Minutes) 1 Maximum Piping Pressure (psi / bar) 950 / 66 Maximum Turbidity (NTU) < 1 Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature. Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow axeonwater.com MKTF-382-C AXEON is a registered trademark of AXEON Water Technologies. 05/ AXEON Water Technologies

79

80 EDI Series Electrodeionization Systems AXEON EDI Series Electrodeionization Systems are a superior option to conventional mixed-bed deionization. EDI does not require regeneration and there are no chemicals used for operation. Ultrapure water is produced from reverse osmosis permeate only using electricity to continuously drive ions through deionization resins and ion selective membranes and in to a small concentrate stream. The AXEON EDI Series Electrodeionization Systems are available in four flow ranges. Additional systems can be arranged in parallel for increased capacity. AXEON EDI Series Electrodeionization Systems can be used in applications for ultrapure water. EDI 005 EDI Electrodeionization System Features Easy Operation with Minimal Instrumentation 2 MΩ Dl Sensor with Red/Green Indicator Lights Compact Aluminum Skid Design Sleek, Clean Look Operates Independently from RO System Internal Flow Orifices Benefits No Operator Flow Settings Flow Control is Internal Reliable, Uninterrupted 24/7 Operation Operating Cost (Electrical) is Pennies Per Day Greatly Reduces Disruptive Customer Site Visits Ideal for Remote Locations Chemical Free, Environmentally Friendly Includes 5 Micron Prefilter 5-2

81 EDI Series Electrodeionization Systems Product Specifications Models EDI 001 EDI 003 EDI 005 EDI 007 Design Nominal Capacity (gpm / lpm) 1 / / / / 26.5 Operating Pressure Nominal Maximum (psi / bar) / / / / 3 5 Nominal Discharge Concentrate + Electrode (gpm / lpm) 0.10 / / / / 2.65 Nominal Recovery % Feed Water Specifications Feed Conductivity 1 Total CO2 + HCO3 Hardness Organics Metals Optimum FCE <9µS/cm Max FCE 33µS/cm < 5 mgn CO2 + HCO3 (Optimum < 2 mg/l CO2 + HCO3) < % recovery (ask about higher hardness) < 0.5 ppm TOC < 10 ppb Feed Temp Optimum: 15 C 30 C Range: (5 C 35 C) Feed ph Optimum: Range: Feed Chlorine Silica, SiO2 System Component Specifications Pressure Gauge ND < 0.5 ppm At Filter Outlet: Stainless Steel Case, Bronze Internals. Glycerin filled Pressure Regulator Nickel Plated Bronze 3/4. Set at 40 psi (2.7 bar) Piping 3/4 PVC, Schedule 80 Valves Inlet Isolation Ball Valve, 2 Sample Valves Flow Control Product, Concentrate & Electrode Flow Control Orifices Switches Off/On Switch, Feed Low Pressure Cut out, Concentrate Low Flow Cut out Filters 5 Micron Prefilter, 20 Feed / Product 3/4 FNPT Product Quality 2 MΩ Dl Quality Indicator with Red Green Indicator & Alarm Typical Product Quality: MΩ *Depends on FCE 1 of RO Permeate System Electrical Power Usage Nominal 200W 300W 400W 600W Power Usage Maximum 800W 1.2 kw 1.6kW 1.6kW Electrical Input VAC, 50/60Hz, 1 Phase, FLA 20A Systems Dimensions Approximate Dimensions* L x W x H (in / cm) x x 60 / x x x x 60 / x x x x 60 / x x x x 60 / x x Approximate Weight (lbs / kg) 125 / / / / 73 1: FCE = Conductivity * (CO2) * (SiO2). Example: Conductivity = 5.0µS/cm, CO2 = 3.5 mg/l,, SiO2 = 0.5 mg/l FCE = * (3.5)+1.94* (0.5) = 15.71µS/cm Note: Conductivity (µs/cm) ~ 2.22* TDS (mg/l) * Does not include operating space requirements. Benefits of Using EDI Operating Cost is Minimized No Hazardous Waste, No Associated Costs and Risks No Chemicals Required Flexible Easy to Expand a Modular EDI System Reliable No Recirculation System Components to Fail Reduce Service Visits Customer Security Concerns Overcome Ideal Whenever Ion Exchange Tanks are not Economically or Logistically Feasible. Ultrapure Water Quality Greater than 2 mω/cm (0.05 µs/cm) High Recovery of 90%+ Economically Priced Ideal to Lease for Recurring Revenue and Rapid ROI EDI Technology No Concentrate Recirculation or Brine Injection Thin Cell Efficient Technology Thin Concentrate Non Scaling Technology Unique Non Scaling Electrode System Patented Excellion Membrane axeonwater.com MKTF-495-A AXEON is a registered trademark of AXEON Water Technologies. 10/ AXEON Water Technologies 5-3

82

83

84 CIP Series Clean In Place Systems AXEON Clean In Place Systems (CIP) are mobile skids used for cleaning membranes without removing them from the reverse osmosis system. The CIP systems are designed to be easily integrated with any of the AXEON X Series or M Series reverse osmosis models. However, these CIP systems are also engineered as standalone systems that are compatible with any manufacturer s membrane system. AXEON Clean In Place Systems vary in size according to the number of membrane vessels that are to be cleaned in parallel, which is determined by the number of vessels in the first stage of the reverse osmosis skid. A centrifugal pump provides the recirculation flow and pressure recommended by the membrane manufacturer. A built in recycle loop allows for mixing of cleaning agents prior to use and tank level switches to protect the pump. Options include an immersion heater and a ph monitor. CIP 100 Clean In Place System AXEON also offers the C Series Membrane Cleaners for use with AXEON Clean In Place Systems. The C Series Cleaners are compatible with all brands of reverse osmosis, nanofiltration and ultrafiltration membranes. Features On / Off Switch AXEON by Pall Series Bag Filter Housing AXEON 10 Micron Sediment Bag Filter AXEON 316L Stainless Steel Pressure Gauges SCH 80 PVC Piping with Unions Mixing Loop with Valve Solution Tank (Polyethylene) Tank Level Switches Temperature Gauge AXEON Flow Meter 316L Stainless Steel Pump with TEFC Motor Hose Kit Caster Wheels Options Stainless Steel Immersion Heater ph Monitor Cleaning System Model Inlet Outlet (in) Tank Size (gal / ltr) Flow Rate (gpm / lpm) Product Specifications Motor (HP) Approximate Dimensions* L x W x H (in / cm) Weight (lb / kg) CIP / / x 27 x 55 / 107 x 69 x / 136 CIP / / x 35 x 65 / 158 x 89 x / 249 CIP / / x 40 x 73 / 163 x 102 x / 272 CIP / / x 40 x 73 / 163 x 102 x / 295 * Does not include operating space requirements axeonwater.com 6-2 MKTF-200-E AXEON is a registered trademark of AXEON Water Technologies. 12/ AXEON Water Technologies

85

86 7-2

87 7-3

88 7-4

89

90 8-2

91 8-3

92

93

94 Chemical Injection Systems AXEON Chemical Injection Systems offer a wide range of capacities to meet various chemical treatment applications. Each system is composed of a chemical pump and polyethylene chemical tank, along with the necessary hoses and fittings for the pump. AXEON Chemical Injection Systems have been designed to the highest industry standards and are available in capacities from 4 to 30 GPD. These systems feature quality components, which allows for easy maintenance and servicing. AXEON Chemical Injection Systems feature Pulsafeeder Chem Tech Series XP pumps with peristaltic technology that delivers worry free dosing in a modern design. Each component of the Series XP is designed and manufactured for optimum reliability and durability for real performance. Benefits Reliable Metering Performance Mixed Fluid Capable, Inherently Degassing Extended Tube Life Rugged, Sealed Gear Train Easy Tube Change Out Self Priming Chemical Resistant Materials Simple Installation Heavy Duty Tanks Compatible with Acids, Caustics and Most Water Treatment Chemicals Features Electronic Timer Module Provides a 201 Turndown Control for Enhanced Flexibility Standard Neoprene Tube Resulting in Extended Tube Life Peristaltic Technology Offers Optimum Reliability Rugged Gear Train Removable Tank Cover with 22 Surface for Mixer, and Mounting Surface for Chemical Metering Pump Integral 2 and 1 Female Top Connections and 5 Inspection Port 100 Pound Rating Tank Cover Applications Water Purification and Pollution Control Iron, Hydrogen Sulfide and Manganese Removal Scale Prevention Acid Water Neutralization Coagulation Removal Waste Water Treatment Detergent and Wetting Agent Metering 9-2

95 Chemical Injection Systems Part Number Model Flow Rating (gpd / lph) Tank Size (gal/ ltr) Product Specifications Pressure Rating (psi / bar) Single Head Options Duplex H Tube L Tube F Tube L Tube XP / / / / / / V XP / / / / / / V XP / / / / / / V XP / / / / / / V XP / / / / / V XP / / / / / V XP / / V Tube Size Speed (rpm) Voltage Technical Specifications Dimensions (in / mm) 20:1 Turndown 1/4 or 3/8 Tube Fittings 110 VAC/60 HZ, 1/6 HP 220 VAC/50/60 HZ 104 F / 40 C max. 28 lbs. / kg. [825.25] [685.80] 27.0 AXEON Chemicals Also Available axeonwater.com MKTF-129-C AXEON is a registered trademark of AXEON Water Technologies. 01/ AXEON Water Technologies 9-3