Sound power levels on cooling. mode. db G Refrigerant R410A GWP 1975 *1 SEER B B. kw SCOP

Size: px
Start display at page:

Download "Sound power levels on cooling. mode. db G Refrigerant R410A GWP 1975 *1 SEER B B. kw SCOP"

Transcription

1

2 A Model B Indoor unit PEAD-RP100JALQ PEAD-RP100JALQ C Outdoor Unit PUHZ-SHW112VHA(-BS) PUHZ-SHW112HA(-BS) D Sound power levels on cooling E Inside db mode F Outside db G Refrigerant R410A GWP 1975 *1 SEER H Cooling J Energy efficiency class B B K Annual electricity consumption *2 kwh/a L Design load kw SCOP J Energy efficiency class A A K Annual electricity consumption *2 kwh/a L Design load kw Heating at reference design temperature (Average De- P kw 11.2 (-10 ) 11.2 (-10 ) M at bivalent temperature season) clared R kw 11.2 (-7 ) 11.2 (-7 ) capacity at operation limit S kw 9.4 (-25 ) 9.4 (-25 ) temperature T Back up heating capacity kw

3

4 PRODUCT IFORMATIO (*) PACKAGED AIR CODITIOER IDOOR MODEL PEAD-RP100JALQ OUTDOOR MODEL PUHZ-SHW112HA(-BS) If function includes heating: Indicate the heating season the Function (indicate if present) information relates to. Indicated values should relate to one heating season at a time. Include at least the heating season Average (mandatory) cooling Warmer (if designated) heating Colder (if designated) Item symbol value unit Item symbol value unit Design load Seasonal efficiency cooling Pdesignc 10.0 kw cooling SEER heating/average Pdesignh 12.7 kw heating/average SCOP/A heating/warmer Pdesignh x kw heating/warmer SCOP/W heating/colder Pdesignh x kw heating/colder SCOP/C Declared capacity for cooling, at indoor temperature 27(19) Declared energy efficiency ratio, at indoor temperature 27(19) and outdoor temperature Tj and outdoor temperature Tj Tj=35 Pdc 10.0 kw Tj=35 EERd Tj=30 Pdc 7.3 kw Tj=30 EERd Tj=25 Pdc 5.4 kw Tj=25 EERd Tj=20 Pdc 5.6 kw Tj=20 EERd Declared capacity for heating/average season, at indoor Declared coefficient of performance/average season, at indoor Tj=-7 Pdh 11.2 kw Tj=-7 COPd Tj=2 Pdh 6.8 kw Tj=2 COPd Tj=7 Pdh 4.4 kw Tj=7 COPd Tj=12 Pdh 5.1 kw Tj=12 COPd Tj=bivalent temperature Pdh 11.2 kw Tj=bivalent temperature COPd Tj=operating limit Pdh 9.4 kw Tj=operating limit COPd Declared capacity for heating/warmer season, at indoor temperature 20 and outdoor temperature Tj Declared coefficient of performance/warmer season, at indoor Tj=2 Pdh x kw Tj=2 COPd Tj=7 Pdh x kw Tj=7 COPd Tj=12 Pdh x kw Tj=12 COPd Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd Tj=operating limit Pdh x kw Tj=operating limit COPd Declared capacity for heating/colder season, at indoor Declared coefficient of performance/colder season, at indoor temperature 20 and outdoor temperature Tj Tj=-7 Pdh x kw Tj=-7 COPd Tj=2 Pdh x kw Tj=2 COPd Tj=7 Pdh x kw Tj=7 COPd Tj=12 Pdh x kw Tj=12 COPd Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd Tj=operating limit Pdh x kw Tj=operating limit COPd Tj=-15 Pdh x kw Tj=-15 COPd Bivalent temperature Operating limit temperature heating/average Tbiv -7 heating/average Tol -25 heating/warmer Tbiv x heating/warmer Tol x heating/colder Tbiv x heating/colder Tol x Cycling interval capacity Cycling interval efficiency for cooling Pcycc x kw for cooling EERcyc for heating Pcych x kw for heating COPcyc Degradation co-efficient cooling Cdc Degradion co-efficient heating Cdh Electric power input in power modes other than 'active mode' Annual electricity consumption off mode POFF 15 W cooling QCE 714 kwh/a standby mode PSB 15 W heating/average QHE 4664 kwh/a thermostat - off mode PTO(c/h) 212/74 W heating/warmer QHE x kwh/a crankcase heater mode PCK 0 W heating/colder QHE x kwh/a Capacity control (indicate one of three options) fixed Other items Sound power level (indoor/outdoor) LWA 63/69 db(a) staged Global warming potential GWP 1975 kgco2eq. variable Rated air flow (indoor/outdoor) /6000 m3/h MITSUBISHI ELECTRIC CORPORATIO SHIZUOKA WORKS Contact details for obtaining , Oshika, Suruga-ku, Shizuoka , Japan more information melshierp@nb.mitsubishielectric.co.jp (*) This information is based on the "product information requirement" in COMMISSIO REGULATIO (EU) o206/2012.

5 TECHICAL DOCUMETATIO ( 1 ) PACKAGED AIR CODITIOER IDOOR MODEL PEAD-RP100JALQ 250H1400W732D (mm) OUTDOOR MODEL PUHZ-SHW112HA(-BS) 1350H950W330D (mm) Function cooling heating The heating season Average (mandatory) Warmer (if designated) Colder (if designated) Capacity control fixed staged variable Item Seasonal efficiency ( 2 ) symbol value unit cooling SEER heating/average SCOP/A heating/warmer SCOP/W heating/colder SCOP/C Energy efficiency class cooling SEER B - heating/average SCOP/A A - heating/warmer SCOP/W heating/colder SCOP/C Other items Sound power level (indoor/outdoor) LWA 63/69 db(a) Refrigerant - R410A - Global warming potential GWP 1975 kgco2eq. identification and signature of the person empowered to Hideyo Tamura bind the supplier Manager, Packaged Air Conditioners Quality Control Section MITSUBISHI ELECTRIC CORPORATIO SHIZUOKA WORKS (1) This information is based on COMMISSIO DELEGATED REGULATIO (EU)o626/2011. (2) SEER/SCOP values are measured based on FprE 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance.