2 Three methods for testing particulate matter emissions Method 5 and d17 Particulate t Matter Emissions i Method 201A PM10 and PM2.5 Emissions Method 202 Condensable Particulate Matter

3 This method is used for the measurement of particulate emissions that are condensable above the filter temperature. Filter Temperature in Method 5 is 250º F (±25º) This method is generally paired with Method 202 to collect all particulate emissions from the source

4 Sample is extracted isokinetically from the stack at the same rate as the stack flow Samples are taken on a traverse across the stack with airflow being measured simultaneously Sample is drawn through h a heated probe then through a heated filter into an impinger train The im i e t i lle t m i t e t The impinger train collects moisture to determine water content of stack gas

5

6 Sample is extracted from the stack exhaust over a period long enough to collect 50 mg of sample material EPA Method 2 is used to determine airflow from the stack EPA Method 3 or 3A is used to determine O2 and CO2 content of the stack gas EPA Method 4 is used to determine moisture content of the gas

7 Filters are recovered from the train Probe, nozzle, and filter housing are washed to collect PM residue Impinger water is measured and silica gel weighed to determine moisture content

8 Filters are dried and weighed gravimetrically to determine PM weight. Probe, nozzle, and filter rinse is dried to determine PM weight Weight of PM, airflow and gas density are g, g y used to calculate the grains per scf and lb/hr of PM emissions

9 Method 17 is comparable to Method 5 except that in this method, the filter housing is kept in stack to keep the filter at stack temperature This method is generally used on low moisture sources as higher moisture in the sample gas can cause issues with filter blockage and damage

10 Method 201A is similar in concept to Method 5 in that it draws air through the sample train to collect particulate matter Sample is drawn through either one or both of the PM10 and PM2.5 cyclones dependent on which size particulate matter is being sampled

11

12

13

14 The first cyclone in the series is designed to cut particulate at the level of PM10 sizing. Particulate collected from this cyclone after sampling is >10 microns The second cyclone cuts the particulate at the level of PM2.5 sizing. Particulate collected from this cyclone after sampling is > 2.5 microns but <10 microns Particulate on the filter, filter housing wash, and in the impinger train is classified as to PM2.5 emissions

15 Sampling time for M201A is longer than that of Method 5 or 201A because the sampling rate is lower to maintain cyclone efficiency Sample rate is constant during the sampling to maintain cyclone efficiency This method is not to be used with sample gas that includes entrained water droplets. These water droplets can be larger than the cut sizes for the cyclones but contain particulate less than the cut sizes

16 Small diameter ducts (generally less than 18 inches for PM10 testing and less than 26.5 inches for combined PM10 and PM2.5 testing) should not be tested with these methods due to blockage of the exhaust stream by the sampling equipment

17 Method 202 is used to determine condensable particulate matter emissions i after the sample gas has been drawn through filters and/or cyclones in the previous methods Water is collected from an impinger train, separated into organic and aqueous fractions, dried and weighed to determine particulate emissions A CPM filter is also used in the train and is weighed after being dried

18

19 Eliminates the use of water as a collection agent in the impingers Adds a condenser after the probe and filter from the sampling train before the gas enters the water dropout impinger A condensable particulate matter (CPM) filter has been added after the water dropout impinger and first modified Greenburg Smith impinger

20 The water from the method is also weighed to determine moisture content of the stack gas The method requires that the CPM filter temperature is maintained between 65º F and 85º F during the test.

21 Testing on sources must be done at 90% or greater of the rated capacity of the source according to IDNR policy Sample ports for particulate testing should be 6 inches in diameter. They are ideally positioned at 8 stack diameter equivalents upstream of any disturbance and 2 diameter downstream of any disturbance. The minimum allowed distance upstream is 2 diameters and ½ diameter downstream. Port locations are determined by EPA Method 1