ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report

Size: px
Start display at page:

Download "ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report"

Transcription

1 Sampling Locations- Near Bromine, Plant/Near ETP. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB 1 PM 10 µg/m PM2.5 µg/m Sulphur Dioxide (SO 2 ) µg/m Oxides of Nitrogen (NO X ) µg/m N.D. N.D. N.D. N.D. 5 Br 2 ppm Cl 2 µg/m 3 N.D.- Not Detectable Note : Sampling, monitoring and analysis conducted by M/S. Kadam Environmental Consultants.

2 Sampling Locations-Near D.G.Set. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB 1 PM 10 µg/m PM2.5 2 Sulphur Dioxide (SO 2 ) 3 4 Oxides of Nitrogen (NO X ) µg/m µg/m µg/m Br 2 ppm 0.1 N.D. N.D. N.D. N.D. 6 Cl 2 µg/m N.D.- Not Detectable Note : Sampling, monitoring and analysis conducted by M/S. Kadam Environmental Consultants.

3 Sampling Locations- D.G.Set. Stack Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB 1 Particulate Matter 2 Sulphur Dioxide (SO 2 ) 4 Oxides of Nitrogen (NO X ) April - 18 May-18 June-18 Avg. mg/nm ppm ppm

4 N.D.- Not Detectable Note : Sampling, monitoring and analysis conducted by M/S. Kadam Environmental Consultants. Sampling Locations- Power Plant. Sr. No. Parameters Unit (SI) Specification/SPCB 1 Particulate Matter 2 Sulphur Dioxide (SO 2 ) 4 Oxides of Nitrogen (NO X ) Stack Air Monitoring Report April - May-18 June-18 Avg. 18 mg/nm ppm ppm

5 N.D.- Not Detectable Note : Sampling,monitoring and analysis conducted by M/S. Kadam Environmental Consultants. Sampling Locations- Bromine Plant Scrubber. Stack Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB April - May-18 June-18 Avg HBr mg/nm 3 5 N.D. N.D. N.D. N.D. 2 Br 2 mg/nm 3 N.A. N.D. N.D. N.D. N.D. N.D.- Not Detectable

6 Note : Sampling, monitoring and analysis conducted by M/S. Kadam Environmental Consultants. Sampling Locations- Bromine Plant Bottling Scrubber. Stack Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB April - May-18 June-18 Avg HBr mg/nm 3 5 N.D. N.D. N.D. N.D.

7 N.D.- Not Detectable Note : Sampling,monitoring and analysis conducted by M/S. Kadam Environmental Consultants. Stack Air Monitoring Report Sampling Locations- Chlorine Charging Station. Sr. No. Parameter s Unit (SI) Specification/ SPCB 1 HBr mg/nm 3 5 N.D. N.D. N.D. N.D. N.D.- Not Detectable Note : Sampling,monitoring and analysis conducted by M/S. Kadam Environmental Consultants.

8 Sampling Locations- ETP Outlet. Effluent Analysis and Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPC B 1 ph Temperature C 3 Colour Pt-CO Suspended mg./l solids 5 Oil & grease mg./l 10 <1 <1 <1 <1 6 Ammonical nitrogen mg./l 50 <0.1 <0.1 <0.1 <0.1 Note : Sampling,monitoring and analysis conducted by M/S. Kadam Environmental Consultants.

9 Sampling Locations- STP Outlet. Effluent Analysis and Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPC B 1 ph Suspended mg./l < solids 3 BOD mg./l Oil & grease mg./l N.A. <1 <1 <1 <1 5 Residual Chlorine mg./l 0.5 ( Minimum) Note : Sampling, monitoring and analysis conducted by M/S. Kadam Environmental Consultants.

10 Noise Level Monitoring Report Sr. No. Locations Unit (SI) Specification/SPCB (Day Time Monitoring) 1 Near Power Plant dba Day Time- 75dBA, Night Time-75dBA 2 Near Bromine Plant dba Day Time- 75dBA, Night Time-75dBA 3 Near R.O/D.M. Plant dba Day Time- 75dBA, Night Time-75dBA 4 Near ETP dba Day Time- 75dBA, Night Time-75dBA 5 ADM Office dba Day Time- 75dBA, Night Time-75dBA Note : Sampling,monitoring and analysis conducted by M/S. Kadam Environmental Consultants.