Air Conditioners 4AC13

Size: px
Start display at page:

Download "Air Conditioners 4AC13"

Transcription

1 PRODUCT SPECIFICATIONS R-40A Refrigerant 3 SEER.5 to 5 Tons High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity Top discharge directs hot air away from living area and shrubbery All units factory run tested Louvered cabinet protects coil from fin damage Easy access to electrical panel Corner mounted service valves for easy hook-up and service Liquid line filter drier furnished for field installation Charged for 5 feet of interconnecting tubing AHRI Certified and ETL listed Region specific models meet the minimum efficiency requirements for U.S. DOE Federal Regional Standards in that area. Warranty Compressor - 5 Year Limited Parts - 5 Year Limited

2 Model Number Identification 4 AC 3 L 4 P - 7,8 A 4 = R-40A AC = Air Conditioner 3 = 3 SEER Nominal L = All Regions (Louvered Cabinet) N = North Region (Louvered Cabinet) A = Minor Revision Code 3 = Major Revision Code Electric P = 08-30v/60Hz/Ph Nominal Capacity 4 = 4,000 Btuh Electrical Data / Specifications All Regions L8P L4P L30P L36P L4P L48P L60P North Region N8P N4P N30P N36P N4P N48P N60P Rated Voltage (Volts) Phase Frequency (Hz.) Voltage Range Maximum Overcurrent Protection Minimum Circuit Ampacity Compressor - Rated Load Amps Compressor - Locked Rotor Amps Fan Motor - Rated Load Amps Fan Motor - HP /0 /0 /5 /5 /4 /4 /4 Fan Motor - Nominal RPM Refrigerant Charge (oz.)* Liquid Line Set 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Weight (lbs) * Factory charge adequate for 5 feet of line set. Adjust per Installation Instructions. Accessories Model Compressor Low Ambient Cut-Off 45F08 45F08 45F08 45F08 45F08 45F08 45F08 Compressor Short Cycle Protection 47J7 47J7 47J7 47J7 47J7 47J7 47J7 Compressor Sound Cover 4W00 4W00 4W00 4W00 4W0 4W0 4W0 Crankcase Heater 93M04 93M04 93M04 93M04 93M04 93M04 93M04 Freezestat - 3/8 93G35 93G35 93G35 93G35 93G35 93G35 93G35 Hard Start Kit 0J4 88M9 88M9 88M9 88M9 88M9 88M9 Loss of Charge Kit 84M3 84M3 84M3 84M3 84M3 84M3 84M3 Low Ambient Kit 34M7 34M7 34M7 34M7 34M7 34M7 34M7 Time Delay Kit 58M8 58M8 58M8 58M8 58M8 58M8 58M8

3 Cooling Performance (All Regions) Outdoor Unit Rated Air Capacity SEER EER Indoor Unit Furnace Indoor Metering Device Indoor Orifice (Required) Field Installed TXV (Optional) AHRI Reference No. L8P-7, 8 7, A*4E(,)* 95AFDF045BV N/A , A*4E(,)* 95AFDF070BV N/A , A*4E(,)* 95AFUH045BV N/A , A*4E(,)* 95AFUH070BV N/A , A*4E(,)*+TD N/A , A*36G(,)* 95AFDF045BV N/A , A*36G(,)* 95AFDF070BV N/A , A*36G(,)* 95AFUH045BV N/A , A*36G(,)* 95AFUH070BV N/A , A*36G(,)*+TD N/A , AH4D(,)B 95AFUH045BV N/A , AH4D(,)B 95AFUH070BV N/A , AH4D(,)B+TD N/A , AH36G(,)B 95AFUH045BV N/A , AH36G(,)B 95AFUH070BV N/A , AH36G(,)B+TD N/A , BCS3M8C****P N/A L4P-7, 8, A*4E(,)* 95AFDF045BV N/A , A*4E(,)* 95AFDF070BV N/A , A*4E(,)* 95AFDF090CV N/A , A*4E(,)* 95AFDF0CV N/A , A*4E(,)* 95AFUH045BV N/A , A*4E(,)* 95AFUH070BV N/A , A*4E(,)* 95AFUH090CV N/A , A*4E(,)*+TD N/A , A*30F(,)*+TD N/A , A*36G(,)* 95AFDF045BV N/A , A*36G(,)* 95AFDF070BV N/A , A*36G(,)* 95AFDF090CV N/A , A*36G(,)* 95AFDF0CV N/A , A*36G(,)* 95AFUH045BV N/A , A*36G(,)* 95AFUH070BV N/A , A*36G(,)* 95AFUH090CV N/A , A*36G(,)*+TD N/A , AH4D(,)B 95AFUH045BV N/A 55990, AH4D(,)B 95AFUH070BV N/A , AH4D(,)B 95AFUH090CV N/A , AH4D(,)B+TD N/A 55990, AH30F(,)B+TD N/A , AH36G(,)B 95AFUH045BV N/A , AH36G(,)B 95AFUH070BV N/A , AH36G(,)B 95AFUH090CV N/A , AH36G(,)B+TD N/A , BCS3M4C****P N/A AHRI Certified to Standard 0/40. Required for AHRI rating. NOTES - All ratings include the use of a blower time delay. All BCS3 air handlers have time delay capabilities. If a coil is matched with a furnace the furnace may require an optional time delay relay for field installation. See furnace or air handler specifications to determine if relay is needed. NOTES - A* = All AU (uncased) and AC (cased) Aire-Flo coils. +TD = Time Delay required. ****P = Piston equipped models.

4 Cooling Performance (All Regions) Outdoor Unit Rated Air Capacity SEER EER Indoor Unit Furnace Indoor Metering Device Indoor Orifice (Required) Field Installed TXV (Optional) AHRI Reference No. L30P-7, 8 8, A*30F(,)*+TD L , A*36G(,)* 95AFDF045BV L , A*36G(,)* 95AFDF070BV L , A*36G(,)* 95AFDF090CV L , A*36G(,)* 95AFDF0CV L , A*36G(,)* 95AFUH045BV L , A*36G(,)* 95AFUH070BV L , A*36G(,)* 95AFUH090CV L , A*36G(,)*+TD L , AH30F(,)B+TD L , AH36G(,)B 95AFUH045BV L , AH36G(,)B 95AFUH070BV L , AH36G(,)B 95AFUH090CV L , AH36G(,)B+TD L , BCS3M30C****P L L36P-7, 8 33, A*36G(,)* 95AFDF090CV L , A*36G(,)* 95AFDF0CV L , A*36G(,)* 95AFUH090CV L , A*36G(,)* 95AFUH0CV L , A*36G(,)*+TD L , A*4A(,)* 95AFDF090CV L , A*4A(,)* 95AFDF0CV L , A*4A(,)* 95AFUH090CV L , A*4A(,)* 95AFUH0CV L , A*4A(,)*+TD L , AH36G(,)B 95AFUH090CV L , AH36G(,)B 95AFUH0CV L , AH36G(,)B+TD L , BCS3M36C****P L L4P-7, 8 40, A*48D(,)* 95AFUH0CV M , A*48D(,)*+TD M , AH48C(,)C 95AFUH0CV M , AH48C(,)C+TD M , BCS3M4C****P M L48P-7, 8 46, A*48D(,)*+TD M , AH48C(,)C+TD M , BCS3M48C****P M L60P-7, 8 57, A*60G(,)*+TD M , AH60D(,)C+TD M , AH60D(,)D+TD M , BCS3M60C****P M AHRI Certified to Standard 0/40. Required for AHRI rating. NOTES - All ratings include the use of a blower time delay. All BCS3 air handlers have time delay capabilities. If a coil is matched with a furnace the furnace may require an optional time delay relay for field installation. See furnace or air handler specifications to determine if relay is needed. NOTES - A* = All AU (uncased) and AC (cased) Aire-Flo coils. +TD = Time Delay required. ****P = Piston equipped models.

5 Cooling Performance (North Region) Outdoor Unit Rated Air Capacity SEER EER Indoor Unit Furnace Indoor Metering Device Indoor Orifice (Required) Field Installed TXV (Optional) AHRI Reference No. N8P-7, 8 8, BCS3M8C****P N/A N4P-7, 8 3, BCS3M4C****P N/A , BCS3M30C****P L N30P-7, 8 8, BCS3M30C****P L , BCS3M36C****P L N36P-7, 8 35, BCS3M4C****P M N4P-7, 8 4, BCS3M4C****P M N48P-7, 8 49, BCS3M48C****P M N60P-7, 8 58, BCS3M60C****P M AHRI Certified to Standard 0/40. Required for AHRI rating. NOTES - All ratings include the use of a blower time delay. All BCS3 air handlers have time delay capabilities. If a coil is matched with a furnace the furnace may require an optional time delay relay for field installation. See furnace or air handler specifications to determine if relay is needed. NOTES - A* = All AU (uncased) and AC (cased) Aire-Flo coils. +TD = Time Delay required. ****P = Piston equipped models.

6 Sound Ratings Model Sound Rating dba Dimensions Model Cabinet Width (A) in 4-/4 4-/4 4-/4 4-/4 Cabinet Depth (B) in 4-/4 4-/4 4-/4 4-/4 Height (C) in 5-/4 5-/4 9-/4 9-/4 Model Cabinet Width (A) in 8-/4 8-/4 8-/4 Cabinet Depth (B) in 8-/4 8-/4 8-/4 Height (C) in 9-/4 33-/4 9-/4

7

8 Revisions Sections Dimensions Description of Change Updated (6/5) Aire-Flo Heating and Cooling, 05