VAC measuring instrument

Size: px
Start display at page:

Download "VAC measuring instrument"

Transcription

1 Data sheet VAC measuring instrument The service instrument for ventilation and air conditioning systems Point and timed mean value calculation Direct display of the volume flow Automatic allocation of duct cross-section area to measurement site (max. 99 measurement sites) Internal measurement value store (3000 measurement values) PC software for the analysis, archiving and documentation of the measurement values (option) Measurement of up to 6 measurement parameters simultaneously C %RH m/s hpa ppm CO 2 ppm CO This service instrument is s real multi-talent: the has two probe inputs for the connection of a broad range of probes for measurements on ventilation/air conditioning systems. The instrument records flow velocity values in a duct, at a duct outlet or on extraction systems. In addition to this, the allrounder measures or calculates the parameters volume flow, Indoor Air Quality, temperature, relative humidity, dewpoint, absolute humidity, degree of humidity, enthalpy, pressure and CO. At the simple press of a button, the displays the last measurment value measured as well as minimum, maximum and mean values. In addition to this, measurement data can be stored according to measurement site and analyzed on a PC, or documented on site with the Testo fast printer.

2 Technical data, VAC measuring instrument, incl. battery and calibration protocol General technical data Operating temperature 0 to +50 C Storage temperature Display LCD, 4 lines Battery type 9V block battery Battery life PC Weight Housing material 45 h RS232 interface 255 g ABS Memory x 68 x 47 mm Battery life: 6-45 h (depending on probe) Mains conn. and batt. rech. in instr. Calculated humidity parameters: td, g/m 3, g/kg pressurecompensated, J/g Calculated volume flow: m 3 /h (e.g. 0 to m 3 /h), m 3 /min, m 3 /s, I/s, cfm Calculated velocity values (density-compensated): 0 to 100 m/s; 0 to m 3 /h Humidity measurement: Measuring range -50 to 180 C; See Probes for accuracy Accuracy of Type K, J: Additional error via operation temperature 0.2 C (adjustment point) Display of 2 measurement parameters Simultaneous measurement of up to 6 parameters

3 Technical data / Accessories Sensor type Measuring range Accuracy ±1 digit Resolution Type K (NiCr-Ni) -200 to C ±0.5% of m.v. (-200 to C) 0.1 C (-200 to C) ±0.5% of m.v. (+60.1 to C) ±0.3 C (-60 to +60 C) Type J (Fe-CuNi) -200 to C ±0.5% of m.v. (-200 to C) 0.1 C (-200 to C) ±0.5% of m.v. (+60.1 to C) ±0.3 C (-60 to +60 C) NTC -50 to +150 C ±0.5% of m.v. (+100 to +150 C) 0.1 C (-50 to +150 C) ±0.2 C (-25 to C) ±0.4 C (-50 to C) ±0.4 C (+75 to C) Testo humid. sensor, cap. See probe data 0.1 %RH () Vane 0 to +60 m/s See probe data 0.01 m/s (0 to +60 m/s) Thermal 0 to +20 m/s See probe data 0.01 m/s (0 to +10 m/s) 0.1 m/s (+10.1 to +20 m/s) Pressure See pressure probes ±0.1% of m.v hpa (Sonde ) hpa (Sonde ) 0.01 hpa (Sonde ) 1 hpa (Sonde ) CO2 probe 0 to +1 Vol. % CO 2 See probe data 0 Vol. % CO 2 (0 to +1 Vol. % CO 2 ) CO2 probe 0 to ppm CO 2 ±(100 ppm CO 2 +3% of m.v.) (+5000 to ppm CO 2 ) ±(500 ppm CO 2 +2% of m.v.) (0 to ppm CO 2 ) CO probe 0 to +500 ppm CO ±5% of m.v. (+100 to +500 ppm CO) ±5 ppm CO (0 to +100 ppm CO) 1 ppm CO 2 (0 to ppm CO 2 ) 1 ppm CO (0 to +500 ppm CO) Transport and Protection System case (plastic) for measuring instrument, probes and accessories probes in lid make it easy to find parts in case (540 x 440 x 130 mm) TopSafe (indestructible protection case), with bench stand and belt clip Printer and Accessories Testo fast printer IrDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries with individual cell charging and charge control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug, V, 300 ma, 50/60 Hz Spare thermal paper for printer (6 rolls), permanent ink measurement data documentation legible for up to 10 years Software and Accessories ComSoft Professional Pro software incl. data archiving RS232 cable connects instrument to PC (1.8 m) for data transfer

4 Accessories Additional accessories and spare parts 9V rech. battery for instrument, instead of battery Desk-top power supply with international connection options Professional telescopic handle for plug-in vane probes, max. 1 m long Handle for plug-in vane probes Extension cable, 5 m long, between plug-in head cable and instrument, PUR coating material Connection hose; silicone; length 5 m; max. load 700 hpa (mbar) Silicone heat paste (14g), Tmax = +260 C, improves heat transfer in surface probes Cable, 1.5 m long, connects probe with plug-in head to meas. instrument, PUR coating material Cable, 5 m long, connects probe with plug-in head to measuring instrument, PUR coating material Adapter to connect NiCr-Ni thermocouples and probes with open wire ends Control and adjustment set for Testo humidity probes, salt solution with 11.3% RH and 75.3% RH, incl. adapter for Testo humidity probes testo saline solution pot for checking humidity probes, 33 %RH Calibration Certificates ISO calibration certificate velocity hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s ISO calibration certificate velocity hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s DAkkS calibration certificate velocity hot wire, vane anemometer; calibration points 0.5; 1; 2; 5; 10 m/s DAkkS calibration certificate/velocity hot wire, vane anemometer, Pitot tube; calibration points 2; 5; 10; 15; 20 m/s ISO calibration certificate humidity Calibration points 11.3 %RH and 75.3 %RH at +25 C ISO calibration certificate/humidity saturated saline solutions: calibration point 11.3%RH ISO calibration certificate/humidity saturated saline solutions, calibration point 75.3%RH DAkkS calibration certificate/humidity electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25 C

5 Probes Probe shaft/probe shaft tip Measuring range Accuracy Flow velocity probes Vane/temperature probe, Ø 16 mm, attachable to handle or telescopic handle 180 mm +0.6 to +60 m/s -30 to +140 C ±(0.2 m/s +1% of m.v.) (+0.6 to +40 m/s) ±(0.2 m/s +2% of m.v.) (+40.1 to +50 m/s) Ø 16 mm Vane/temperature probe, Ø 25 mm, can be attached to handle or telescopic handle 180 mm Ø 25 mm +0.6 to +40 m/s -30 to +140 C ±(0.2 m/s ±1% of m.v.) (+0.6 to +40 m/s) Bendable vane probe (can be bent by 90 ), Ø 60 mm, attachable to handle or telescopic handle , for meas. on ventilation outlets Ø 60 mm to +20 m/s Operating temperature 0 to +60 C ±(0.1 m/s ±1.5% of m.v.) (+0.25 to +20 m/s) Bendable vane probe (can be bent by 90 ), Ø 100 mm, attachable to handle or telescopic handle , for measurements on ventilation outlets Ø 100 mm +0.1 to +15 m/s Operating temperature 0 to +60 C ±(0.1 m/s ±1.5% of m.v.) (+0.1 to +15 m/s) Affordable, robust hot bulb probe, Ø 3 mm, for measurements in the lower velocity range, with handle 150 mm Ø 4 mm Ø 3 mm 0 to +10 m/s ±(0.03 m/s ±5% of m.v.) (0 to +10 m/s) Robust hot bulb probe, Ø 3 mm, with handle and telescopic handle for measurements in the lower velocity range 850 mm Ø 3 mm 0 to +10 m/s ±(0.03 m/s ±5% of m.v.) (0 to +10 m/s) Quick-action hot wire probe, Ø 10 mm, with telescopic handle, for measurements in the lower velocity range with direction recognition 760 mm Ø 10 mm 0 to +20 m/s ±(0.03 m/s ±4% of m.v.) (0 to +20 m/s) Robust hot bulb probe, Ø 3 mm, for measurements in the lower velocity range, 2m cable (PVC) 150 mm Ø 3 mm 0 to +10 m/s ±(0.03 m/s ±5% of m.v.) (0 to +10 m/s) Thermal anemometer probe, Ø 10 mm, w. telescopic handle, measures air flow in lab fume cupboards to DIN EN mm Ø 10 mm 0 to +5 m/s 0 to +50 C ±(0.02 m/s ±5% of m.v.) (0 to +5 m/s) Vane probe, Ø 16 mm, with telescopic handle, Tmax +60 C 700 mm +0.6 to +40 m/s ±(0.2 m/s ±1.5% of m.v.) (+0.6 to +40 m/s) Ø 16 mm High temperature vane probe, Ø 25 mm, with handle for continuous measurements up to +350 C 560 mm +0.6 to +20 m/s -40 to +350 C ±(0.3 m/s ±1% of fsv) (+0.6 to +20 m/s) Ø 25 mm

6 Probes Probe shaft/probe shaft tip Measuring range Accuracy Pressure Precision pressure probe, 100 Pa, measures differential pressure and velocities (in combination with Pitot tube) 0 to +100 Pa ±(0.3 Pa +0.5% of m.v.) (0 to +100 Pa) Pressure probe, 10 hpa, measures differential pressure and velocities (in combination with Pitot tube) 0 to +10 hpa ±0.03 hpa (0 to +10 hpa) Pressure probe, 100 hpa, measures differential pressure and velocities (in combination with Pitot tube) 0 to +100 hpa ±0.5% of m.v. (+20 to +100 hpa) ±0.1 hpa (0 to +20 hpa) Pressure probe, 2000 hpa, measures absolute pressure 0 to hpa ±5 hpa (0 to hpa)

7 Probes Probe shaft/probe shaft tip Measuring range Pitot tubes Pitot tube, 500 mm long, Ø 7 mm, stainless steel, for measuring flow velocity 500 mm Ø 7 mm Operating temperature 0 to +600 C Pitot tube, 350 mm long, Ø 7 mm, stainless steel, for measuring flow velocity 350 mm Ø 7 mm Operating temperature 0 to +600 C Pitot tube, 1000 mm long, stainless steel, for measuring flow velocity 1000 mm Ø 7 mm Operating temperature 0 to +600 C Pitot tube, stainless steel, 1000 mm long, measures velocity with temperature, for pressure probes /..1445/ mm Ø 8 mm Type K (NiCr-Ni) -40 to +600 C Pitot tube, stainless steel, 500 mm long, measures velocity with temperature, for pressure probes /..1445/ mm Ø 8 mm Type K (NiCr-Ni) -40 to +600 C

8 Probes Probe shaft/probe shaft tip Measuring range Accuracy t 90 More probes 3-function probe for simultaneous measurement of temperature, humidity and velocity. With plug-in head, connection cable required 270 mm Ø 21 mm 0 to +10 m/s ±(0.03 m/s +5% of m.v.)(0 to 10 m/s) ±2 %RH (+2 to +98 %RH) ±0.4 C (0 to +50 C) ±0.5 C (remaining range) Comfort level probe for measuring degree of turbulence, with telescopic handle and stand. Fulfills EN requirements 890 mm Ø 90 mm 0 to +5 m/s 0 to +50 C ±(0.03 m/s +4% of m.v.) (0 to +5 m/s) ±0.3 C (0 to +50 C) Ambient CO2 probe, Plug-in head, Vol. % CO ppm CO 2 ±(75 ppm CO 2 +3% of m.v.) (0 to ppm CO 2 ) ±(150 ppm CO 2 +5% of m.v.) (+5001 to ppm CO 2 ) Ambient CO probe, for detecting CO in buildings and rooms; 0 to +500 ppm 0 to +500 ppm CO ±5% of m.v. ( to +500 ppm CO) ±5 ppm CO (0 to +100 ppm CO) Humidity probes Standard ambient air probe up to +70 C, Plug-in head. connection cable or required ±2 %RH (+2 to +98 %RH) ±0.4 C (-10 to +50 C) ±0.5 C (remaining range) 12 s Thin humidity probe incl. 4 attachable protection caps for ambient air measurements, measurements in exhaust air ducts and equilibrium moisture measurements, Plug-in head. 250 mm Ø 4 mm ±2 %RH (+2 to +98 %RH) ±0.4 C (-10 to +50 C) ±0.5 C (-20 to C) ±0.5 C (+50.1 to +70 C) 15 s Highly accurate reference humidity/ temp. probe, Plug-in head. Ø 21 mm ±1 %RH (+10 to +90 %RH)* ±2 %RH (remaining range) ±0.2 C (+10 to +40 C) ±0.4 C (remaining range) * in the temperature range from +15 C to +30 C 12 s High humidity level probe w/ heated sensor element, no humidity on sensor, Plug-in head. 300 mm -20 to +85 C ±2.5 %RH () ±0.4 C (-10 to +50 C) ±0.5 C (-20 to C) ±0.5 C (+50.1 to +100 C) 30 s

9 Probes Probe shaft/probe shaft tip Measuring range Accuracy t 90 Humidity probes Robust humidity probe e.g. for measuring equilibrium moisture or for measurements in exhaust ducts to +120 C, Plug-in head. 300 mm -20 to +120 C ±2 %RH (+2 to +98 %RH) ±0.4 C (-10 to +50 C) ±0.5 C (remaining range) 30 s Robust high temperature/humidity probe up to +180 C, Plug-in head. 300 mm -20 to +180 C ±2 %RH (+2 to +98 %RH) ±0.4 C (+0.1 to +50 C) ±0.5 C (remaining range) 30 s Flexible humidity probe (does not retain shape) for measurements in inaccessible places, Plug-in head mm 100 mm -20 to +180 C ±2 %RH (+2 to +98 %RH) ±0.4 C (+0.1 to +50 C) ±0.5 C (-20 to 0 C) ±0.5 C (+50.1 to +180 C) 30 s Standard pressure dewpoint probe for measurements in compressed air systems, Plug-in head. 300 mm -20 to +50 C tpd ±0.9 C tpd (+5 to +50 C tpd) ±1 C tpd (0 to +4.9 C tpd) ±2 C tpd (-5 to -0.1 C tpd) ±3 C tpd (-10 to -5.1 C tpd) ±4 C tpd (-20 to C tpd) Precision pressure dewpoint probe for measurements in compressed air systems incl. cert. with test point -40 C tpd, Plug-in head. 300 mm -40 to +50 C tpd ±0.8 C tpd (-4.9 to +50 C tpd) ±1 C tpd (-9.9 to -5 C tpd) ±2 C tpd (-19.9 to -10 C tpd) ±3 C tpd (-29.9 to -20 C tpd) ±4 C tpd (-40 to -30 C tpd) Humidity/temperature probe, Plug-in head. connection cable or Ø 21 mm %RH ±2 %RH ( %RH) ±0.4 C (+0.1 to +50 C) ±0.5 C (-20 to 0 C) ±0.5 C (+50.1 to +70 C) 12 s Probes aw value aw value set: pressure-tight precision humidity probe with certificate, measurement chamber and 5 sample bowls (plastic), Reproducibility of aw value ± to +1 aw ±0.01 aw (+0.1 to +0.9 aw) ±0.02 aw (+0.9 to +1 aw) ±1 %RH (+10 to +90 %RH) ±2 %RH (0 to +10 %RH) ±2 %RH (+9) ±0.4 C (-10 to +50 C) ±0.5 C (remaining range) Measuring chamber completely

10 Probes Probe shaft/probe shaft tip Measuring range Accuracy t 99 Type K (NiCr-Ni) Quick-action surface probe, Plug-in head. connection cable or 150 mm Ø 10 mm -200 to +300 C Class 2 1) 3 s Super quick-action immersion/ penetration probe for measurements in liquids, Plug-in head. connection cable or 150 mm Ø 1.5 mm -200 to +600 C Class 1 1) 1 s Super quick-action immersion/ penetration probe for high temperatures, Plug-in head. 470 mm Ø 1.5 mm -200 to C Class 1 1) 1 s Spare meas. head for pipe wrap probe, TC Type K 35 mm -60 to +130 C Class 2 1) 5 s mm 1) According to standard EN , the accuracy of Classes 1 / 2 refer to -40 to +1000/+1200 C.

11 Covering caps Illustration For humidity probes Caps for humidity probes Ø 12m and 21mm Metal protection cage, for humidity probes, for measurement in flow velocities of less than 10 m/s , Cap with wire mesh filter, All humidity probes with Ø 12 mm PTFE sintered filter, Ø 21 mm, for corrosive substances, high humidity range (long-term measurements), high velocities Ø 21 mm All humidity probes with Ø 21 mm Sintered PTFE filter,, for corrosive media, High humidity range (long-term measurements), high flow velocities , , PTFE sintered filter,, for corrosive substances, high humidity range (non-stop measurements), high flow speeds , , , Stainless steel sintered cap, Ø 21 mm, can be screwed onto humidity probe, protection in case of high mechanical load and high velocities Ø 21 mm All humidity probes Ø 21 mm Stainless steel sintered filter, pore size 100 µm, probe protection in dusty atmospheres or higher flow velocities, for measurements at higher flow velocities or in contaminated air ,