APPENDIX H AIR DISPERSION MODELLING REPORT BY PROJECT MANAGEMENT LTD. (REF. CHAPTER 11 AIR QUALITY AND CLIMATIC FACTORS)
|
|
- Sharyl Carpenter
- 6 years ago
- Views:
Transcription
1 RP.0001 A Environmental Impact Statement 15 th April 2005 APPENDIX H AIR DISPERSION MODELLING REPORT BY PROJECT MANAGEMENT LTD. (REF. CHAPTER 11 AIR QUALITY AND CLIMATIC FACTORS) S:\Projects\190900\ Centocor\EIS\ RP-0001 A.doc
2
3 CONTENTS 1. EXECUTIVE SUMMARY 3 2. INTRODUCTION 4 3. AIR DISPERSION METHODOLOGY Emissions Modelled Modelling Approach Meteorological Data Building Downwash Terrain Source Data Receptors 8 4. EMISSION INVENTORY AND SOURCE DATA Mass Emission Rates Source Physical Parameters 9 5. MODELLING RESULTS Stack Height Determination Nitrogen Oxides DISCUSSION OF MODEL RESULTS Nitrogen Dioxide CONCLUSIONS 14 APPENDIX 1 Isopleth Charts of the Predicted Ground Level Pollutant Concentrations N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 2
4 1. EXECUTIVE SUMMARY PM carried out modelling analysis of predicted emissions from the proposed Centocor Biologics Ireland plant at Ringaskiddy. An air dispersion model was used to determine the ground level concentrations of nitrogen oxides due to the emissions of the combined heat and power plant and the steam boilers. Predicted ground levels were evaluated against air quality standards. Emissions from the site have been modelled at worst-case emission rates, although in all cases the actual emissions from the plant are likely to be significantly less than these levels. The results of the assessment have shown that the maximum short term (1-hour) ground-level nitrogen oxide concentrations occur to the north east of the facility, while the long term (annual) maximum ground level concentration also occur to the north east of the facility. In summary, it was determined that the minimum appropriate stack height is 30 metres above ground level and it was demonstrated that emissions to atmosphere from the proposed Centocor site will not result in ground level concentrations of pollutants exceeding any applicable air quality standard limit values. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 3
5 2. INTRODUCTION PM carried out an air quality modelling analysis of emissions from the proposed Centocor facility at Ringaskiddy, Co. Cork. The main emission points on the site were modelled; namely emissions from the combined heat and power plant (CHP) and the steam boiler. The ground level concentration of these emissions was calculated over a 3 km radius around the site. The site is set in an established industrial area, bordered by a mix of residential and agricultural uses. Emissions of nitrogen oxides were modelled and the predicted ground level concentrations were evaluated against the Air Quality Standard Regulations. A number of scenarios were run to determine the impact of different operational conditions on the maximum ground level concentrations predicted by the model. Emission rates used in the model represent the maximum permitted emission rate, and consequently the worst-case ground level concentrations. All calculations are based on 5-years of meteorological data, which was collected at Cork Airport meteorology station, which is considered to be representative of the meteorological conditions experienced at the site. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 4
6 3. AIR DISPERSION METHODOLOGY 3.1 Emissions Modelled The model was used to calculate the ground level concentrations of three groups of Nitrogen Oxides (NO X ). The CHP plant and the steam boiler are powered by mains natural gas. The sulphur content of the gas is negligible and thus the potential for the generation of significant emissions of sulphur dioxide does not arise Nitrogen Oxides The major emission points for nitrogen oxides on the site are the CHP plant boilers. The CHP plant consists of a gas turbine coupled to a waste heat recovery boiler with a backup stand-alone steam generation boiler. The operational details of the CHP plant are detailed in Chapter 11 of the main EIS document. Table 1 Emission Scenarios Modelled Scenario Scenario 1 Scenario 2 Scenario 3 Description CHP operating in Open Cycle mode, generating electricity only (emission through CHP bypass stack) CHP operating in Closed Cycle mode, generating steam and electricity (emission through CHP main stack) CHP operating in Closed Cycle mode, generating steam and electricity, with supplementary steam generation by backup boiler (emission through CHP bypass stack and boiler stack) The emission rates which are input to the model are in the form of NO X, thus giving predictions of ground level NO X concentrations. The plant emissions are mainly in the form of NO, but the air quality standards apply only to NO 2. NO 2 is formed in the atmosphere through the oxidation of NO. As there is no long-term site specific monitoring data available for the site for the conversion of NO to NO 2 the NO 2 to NO X ratio is assumed to be 0.75, as recommended by the USEPA guideline on air quality models Emission Rate Assumptions Maximum pollutant concentrations for the CHP and steam boiler emission points were used in the model and the model is therefore conservative as the various emission points will not always discharge at maximum emission concentrations. 1 USEPA, 40 CFR Ch. I ( Edition) Appendix W To Part 51 Guideline On Air Quality Models N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 5
7 3.2 Modelling Approach Dispersion modelling has been carried out using the AERMOD computer model developed by the US EPA. The model consists of mathematical algorithms which simulate the transport and dispersion of air pollutant emissions downwind of a source. AERMOD is a steady-state plume model which represents the plume as having a normal (Gaussian) distribution in both the horizontal and vertical directions for the stable boundary layer (SBL) and the horizontal direction for the central boundary layer (CBL), but a bi-gaussian probability density function for vertical distribution in the CBL. The model predicts average concentrations over 1-hour, 24-hour and annual periods and percentiles thereof. The model allows for the effects of general plume rise, stack tip downwash and building downwash. The choice was made to use AERMOD model instead of the older ISC model as the ISC model is in the process of being replaced as the preferred model by the USEPA. The short-term version of ISC (ISCST3) has several theoretical deficiencies, including a poor characterisation of building downwash and terrain features. AERMOD was developed by the USEPA in response to these deficiencies and is generally regarded as yielding a more theoretically accurate treatment of atmospheric dispersion. AERMOD is increasingly used in Ireland for the assessment of air quality impact and has previously been accepted by the Irish EPA for such assessments. 3.3 Meteorological Data The meteorological data required by the dispersion model is wind speed, wind direction, Pasquill-Gifford stability category, boundary layer height and ambient temperature. The stability category and boundary layer height are used to characterise the turbulence within, and the height of the lower levels of the atmosphere. Extremely unstable conditions can cause plume looping and elevated concentrations close to the stack. Under stable conditions elevated concentrations can occur due to the emissions being trapped below the boundary layer. Neutral conditions, characterised by cloudy skies and strong winds, are most favourable for dispersion due to the mechanical mixing of the lower atmosphere. The wind direction determines the direction in which the plume is blown, and for a particular stability, higher wind speeds will result in reduced plume rise so causing the plume to reach ground level closer to the stack with elevated emission concentrations. The boundary layer height determines the total vertical distance over which the plume may spread. Five years (1999, 2000, 2001, 2002, 2004 * ) of meteorological data for Cork Airport was used. This is considered to be representative of meteorological conditions experienced at the proposed site of the Centocor facility. The data obtained consists of hourly values of wind speed, wind direction, air temperature, stability category and mixing height. Wind direction is converted to a flow vector (the * 2003 data was not used, as it was not a complete data set N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 6
8 direction toward which the emission moves) by adjusting the direction by 180 degrees. The effect of landuse is incorporated into the Meteorological dataset. 3.4 Building Downwash Air streams blowing across buildings can become disrupted, with turbulent eddies occurring downwind in the building wake. If an emission point is sufficiently close to a building, then the plume may become entrained in the turbulent eddies of the building wake. This entrainment can cause plume downwash resulting in elevated emission concentrations close to the emission point. The Good Engineering Practice (GEP) stack height is the minimum height required by a stack in order to avoid structural or building wake-effect induced downwash. Downwash brings pollutants closer to ground level at a shorter downwind distance giving the worst-case scenario for a particular site. The GEP heights and relevant building dimensions were evaluated following USEPA guideline procedures for determining, in each of the 36 wind direction sectors (10 o width/sector), if the building has potential to cause downwash of stack emissions. The stack modelled is subject to downwash and, as a result, direction specific building dimensions were calculated. The AERMOD model interprets the influence zone of each building for a given wind direction using the Building Profile Input Program (BPIP). All of the main proposed buildings on the site were included in the modelling analysis, including warehouses, office/labs area, production building, etc. 3.5 Terrain It was necessary to input a terrain height for each of the receptors on the grid. Terrain heights have been digitised from the ordnance survey of Ireland map of the area surrounding the site. The terrain file included terrain data for a 3 km by 3 km grid centred on the site. Survey data was used for the terrain in the immediate vicinity of the site (1 km). 3.6 Source Data Emissions data and discharge parameters have been provided by CHP manufacturers (Cummins). The emissions have been modelled at the maximum anticipated emission levels, although in all cases the actual emissions from the plant are likely to be significantly less than these levels. The stack discharge parameters and emissions data is summarised in Section 3. The output from each emission point was treated as a point source in the model. Details of the locations and characteristics of the source were inputted to the model using the site layout plan as a template and using information obtained from operations personnel. These details include; stack diameter, height of stack, volumetric flow or velocity and temperature of exhaust gases (heat release). The emission rates were modelled at maximum emission limits to establish the worstcase scenario for air quality impact, while the plant operates within the anticipated requirements of the IPPC licence conditions. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 7
9 3.7 Receptors The model was set up to examine the impact of emissions on the area surrounding the facility using a series of receptors. A receptor is a location at which the model will calculate maximum ground level concentrations. A polar co-ordinate receptor grid system was established with its centre on the facility. Receptors were placed at 500 m intervals over a 3 km by 3 km grid centred on the site. A detailed rectangular 1km by 1km grid was established around the facility with receptors placed at 100m intervals. This detailed grid allowed greater resolution in determining the maximum ground levels concentrations in the areas immediately adjacent to the facility. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 8
10 4. EMISSION INVENTORY AND SOURCE DATA 4.1 Mass Emission Rates The emission values and the corresponding emission rates used in the model are listed below. Table 2 Emission limit values and mass flows Emission Point Emission Concentration Emission Rate* mg/nm 3 g/s Nitrogen Oxides CHP Bypass Stack CHP Main Stack Steam Boiler Stack * The emission rate has been uncorrected from STP to emission conditions. 4.2 Source Physical Parameters The physical parameters of the emission sources are listed below. The model was run at various stack heights as part of the stack height determination exercise. Table 3 Physical Parameters of the Emission Sources Modelled Emission Point Stack Height Diameter Temperature Flow Rate mogl M K Nm 3 /h CHP Bypass Stack CHP Main Stack Steam Boiler Stack 25, 30, ,850 25, 30, ,850 25, 30, ,000 N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 9
11 5. MODELLING RESULTS The ground level concentrations across various averaging periods are summarised in the tables below. An isopleth chart of the predicted ground level concentrations are presented for nitrogen oxides in Appendix A. 5.1 Stack Height Determination There are three main stack emission points from the proposed facility from which oxides of nitrogen will be emitted. These main emission flues will be coupled together in one structure. It is assumed for the purposes of this assessment that the emission from the stacks will be continuous. As the plant will be constructed by a turnkey contractor on a design and build basis, the following stack discharge parameters are based on typical parameters supplied by specialised gas turbine suppliers. In all cases the worst case parameters, i.e. those that would lead to the highest ground level concentrations, are used in the analysis. Although other more simple modelling tools (such as Screen3) are available for the purpose of conducting screening analyses, it was decided to use AERMOD for the screening analysis as this model will be used for a detailed analysis. The screening analysis was carried out using a 3 km square grid as it was found in an initial analysis that the maximum concentration occurred within 3 km of the stack for all stack heights and meteorological conditions. The stack height was assessed at 5m intervals from 25 m to 35 m. The maximum hourly average ground level NOx concentrations were calculated for the range of stack heights for operation of the CHP plant in the closed cycle modes, with the backup boiler in operation. To relate the NOx levels calculated to the Air Quality Standards, a 75 % conversion of NOx to NO 2 is assumed. The trend in concentrations gives an indication as to general plume behaviour as the stack height varies. The results are shown in Figure 1 on the following page. The proposed 99.8th percentile (not to be exceeded for more than 18 hours per annum) limit value is also indicated on Figures 1 for reference. As can be seen in Figure 1 the maximum ground level concentration decreases steadily as the stack height increases. Although the concentrations arising from stacks > 35 metres are lower again, the greater visual impact of these stacks, given the elevated nature of the site, may not be justified as the 30m stack is likely to disperse the stack emissions sufficiently to prevent any adverse air quality impact. The detailed assessment will therefore be carried out on the 30m stack. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 10
12 Ground Level Concentration Concentration (mg/m3) Air Quality Standard (NO2) Stack Height (m) Figure 1 Results of Stack Height Determination (ambient levels in blue) Table 4 Summary Results of Stack Height Assessment Stack Height AQS Average Background* Max Ground Level NOx Max Ground Level NO 2 ** m µg/m 3 µg/m 3 µg/m 3 µg/m * Background concentration taken as twice maximum daily ambient concentration measured. ** The assumed conversion of NOx to NO 2 is 75 % N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 11
13 5.2 Nitrogen Oxides Emissions of nitrogen oxides were modelled at the maximum emission rates. In the assessment of the results it is assumed that 75 % of the NO X is converted to NO 2 in the atmosphere, this is a conservative approach and is used in the absence of longterm monitoring results for the area. The model predicts the short-term (1-hour) maximum concentration will occur to the north-west of the site in the areas of Ballybricken Point. Table 5 Predicted Ground Level Nitrogen Oxide and Nitrogen Dioxide Levels Averaging Period Scenario AQS percentile of Hourly NOx Concentrations µg/m percentile of Hourly NO 2 Concentrations Annual Average NOx µg/m µg/m Annual Average NO 2 µg/m N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 12
14 6. DISCUSSION OF MODEL RESULTS The modelling results demonstrate that atmospheric emissions from the proposed plant do not result in ground level concentrations (GLCs) of pollutants which exceed applicable air quality standard (AQS) limit values. 6.1 Nitrogen Dioxide The maximum predicted GLCs of NO 2 are well below their respective AQS limit values. Scenario 2 represents the normal operational scenario for the CHP plant and shows that the maximum predicted hourly and annual NO 2 GLCs are less than 20 % and 6 % respectively of the AQS limit values. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 13
15 7. CONCLUSIONS A stack height determination resulted in the stack height of 30 meters being selected as the lowest appropriate stack height. Lower levels resulted in poor dispersion and while higher stacks improved dispersion the visual impact is likely to be too high. The stacks at 30 m provide adequate dispersion while minimising visual impacts. All of the emissions were modelled at maximum emission levels. The plant is likely to operate with lower emission rates. The maximum ground level concentrations represent the worst-case of maximum emission rate and meteorological conditions with poor dispersion characteristics. These weather conditions occur less than 10 to 15% of the hours in any one year In summary, the air dispersion model study has demonstrated that emissions to atmosphere from the proposed facility will not result in ground level concentrations of pollutants exceeding any applicable air quality standard (AQS) limit values. The statutory AQS limit values have been designed for the protection of human health and the environment. Therefore atmospheric emissions from the proposed plant are not predicted to have any significant adverse impact on ambient air quality and human health and the environment. N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc 14
16 EIS Air Dispersion Modelling Report Appendix A 15 th April 2005 APPENDIX A ISOPLETH CHARTS OF THE PREDICTED GROUND LEVEL POLLUTANT CONCENTRATIONS N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc Page 1 of 4
17 N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc Page 2 of 4
18 N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc Page 3 of 4
19 N:\101050\22 ENVIRONMENTAL\310 AIR QUALITY\ rp-0003\ RP-0003.doc Page 4 of 4
APPENDIX III. Air Quality Modelling of NO X and PM 10 (2007) RFI Report (Dec 2007)
APPENDIX III Air Quality Modelling of NO X and PM 10 (2007) RFI Report (Dec 2007) 17 EPA Export 25-07-2013:22:32:47 Platin IPPC Licence Application Air Quality Modelling of NOx and PM (2007) EPA Export
More informationMillipore Thermal Oxidiser Emissions Dispersion Modelling Impact Assessment
Millipore Thermal Oxidiser Emissions Dispersion Modelling Impact Assessment Issue No 2 45078628 EPA Export 25-07-2013:19:52:54 Project Title: Report Title: Millipore Thermal Oxidiser Emissions Project
More informationAir Dispersion Modelling Report
Air Dispersion Modelling Report Johnson & Johnson Vision Care (Ireland) Industrial Emissions Licence Review IE0311829-22-RP-0002, Issue: A Issue date: 09 March 2016 Document Sign Off Air Dispersion Modelling
More informationAIR POLLUTION AND ENVIRONMENTAL CONSULTANCY
ENVIROCON ENVIROCON ENVIROCON ENVIROCON ENVIROCON AIR QUALITY IMPACT OF PROPOSED DRYER EXPANSION PROGRAMME AT MALLOW PLANT, CO. CORK ---------- DAIRYGOLD CO-OPERATIVE SOCIETY LTD. CO. CORK ---------- ENVIROCON
More informationComparison of Two Dispersion Models: A Bulk Petroleum Storage Terminal Case Study
Comparison of Two Dispersion Models: A Bulk Petroleum Storage Terminal Case Study Prepared By: Anthony J. Schroeder BREEZE SOFTWARE 12770 Merit Drive Suite 900 Dallas, TX 75251 +1 (972) 661-8881 breeze-software.com
More informationLINN COUNTY PUBLIC HEALTH DEPARTMENT
LINN COUNTY PUBLIC HEALTH DEPARTMENT Air Quality Division M E M O R A N D U M DATE: MARCH 13, 2009 TO: FROM: RE: CC: TONY DAUGHERTY PM2.5 PREDICTED MODELING IMPACTS OF OUTDOOR WOOD BOILERS INTRODUCTION
More informationAir Quality Modelling & Assessment Unit (AQMAU)
Air Quality Modelling & Assessment Unit (AQMAU) AQMAU reference: Project title: AQMAU--RP1 Diesel generator short term NO2 impact assessment Date requested: 13/9/216 AQMAU response date: 1/11/216 1 Summary
More informationREPORT. Offshore Ironsands Project. Air Dispersion Modelling Study - Gas Turbines
REPORT Offshore Ironsands Project Air Dispersion Modelling Study - Gas Turbines Prepared for Prepared by Date Job Number 29303.v2 Distribution: (FILE) 1 copy 1 copy Table of contents 1 Introduction 1 2
More informationREPORT. Offshore Ironsands Project. Air Dispersion Modelling Study - Reciprocating Engines
REPORT Offshore Ironsands Project Air Dispersion Modelling Study - Reciprocating Engines Prepared for Prepared by Date Job Number 29303.v2 Distribution: (FILE) 1 copy 1 copy Table of contents 1 Introduction
More informationApplication of the AERMOD modeling system for air pollution dispersion in the South Pars oilfield
First International Symposium on Urban Development: Koya as a Case Study 339 Application of the AERMOD modeling system for air pollution dispersion in the South Pars oilfield 1,2 1,2 3 M. Rouhi, H. Moradi
More informationEXAMPLE AIR QUALITY ANALYSIS CHECKLIST a
EXAMPLE AIR QUALITY ANALYSIS CHECKLIST a 1. Source location map(s) showing location with respect to:! Urban areas b! PSD Class I areas! Nonattainment areas b! Topographic features (terrain, lakes, river
More information8 AIR QUALITY ASSESSMENT
Environmental Impact Statement Dairygold Mallow Redevelopment Chapter 8 AIR QUALITY 8 AIR QUALITY ASSESSMENT 8.1 INTRODUCTION This chapter describes the potential impacts to the ambient air quality from
More informationModelling Airport Air Quality
Modelling Airport Air Quality David Carruthers Cambridge Environmental Research Consultants Safeguarding Airport Air Quality Manchester 12 April 27 Outline of talk Key factors affecting air quality at
More informationTips to Improve Model Results
Tips to Improve Model Results 2019 Missouri Air Compliance Seminar Joseph Stolle, PE, Senior Environmental Engineer Wendy Vit, PE, Senior Environmental Engineer March 7, 2019 What is an Air Model? Used
More informationModeling For Managers. aq-ppt5-11
Modeling For Managers aq-ppt5-11 Types of Models Near-field *Preferred: EPA AERMOD model 50km CLASS II; Increment Far-field CALPUFF 50km 100+km CLASS I; Chemical Transformation What is used at MPCA History
More informationAbstract. Introduction
Modelling dispersion of pollutants with a simple software - it is a practical approach K. Oduyemi University of Abertay Dundee, Bell Street, Dundee DD1 1HG, UK Abstract One of the most important assessment
More informationATTACHMENT I: EXISTING ENVIRONMENT & IMPACT OF THE ACTIVITY
Industrial Emissions, Application Form, V.3.0, January 2015 ATTACHMENT I: EXISTING ENVIRONMENT & IMPACT OF THE ACTIVITY Attachment I.1 Assessment of Atmospheric Emissions This attachment contains the following:
More informationAppendix VIII: Determination of chimney heights
Appendix VIII: Determination of chimney heights 181 Regional Air Quality Plan for Taranaki 182 Regional Air Quality Plan for Taranaki Appendix VIII: Determination of stack heights and boiler operation
More informationAIR DISPERSION MODELLING GUIDELINE FOR ONTARIO [GUIDELINE A-11]
AIR DISPERSION MODELLING GUIDELINE FOR ONTARIO [GUIDELINE A-11] Version 3.0 Guidance for Demonstrating Compliance with the Air Dispersion Modelling Requirements set out in Ontario Regulation 419/05 Air
More informationRingaskiddy Resource Recovery Centre Environmental Impact Statement
8 Air Quality Introduction The will have one furnace and flue gas cleaning line. The line will have a moving grate furnace with a state-of-the-art flue gas cleaning system. The combustion of waste produces
More informationAIR DISPERSION MODELLING GUIDELINE FOR ONTARIO
July 2005 AIR DISPERSION MODELLING GUIDELINE FOR ONTARIO Version 1.0 Guidance for Demonstrating Compliance with The Air Dispersion Modelling Requirements set out in Ontario Regulation 419/05 Air Pollution
More informationKitimat Airshed Emissions Effects Assessment and CALPUFF Modelling
Kitimat Airshed Emissions Effects Assessment and CALPUFF Modelling EMA of BC - May 2016 Session - Regional Air Topics Anna Henolson Topics to Cover What is Air Dispersion Modelling? Types of Models CALPUFF
More informationAir Dispersion Modelling Guideline for Ontario
Air Dispersion Modelling Guideline for Ontario A Proposal for Consultation Air Dispersion Models and technical information relating to Ontario Regulation 346 (under the Environmental Protection Act) as
More informationModeling 101: Intro to Dispersion Modeling Programs and Process
1 Modeling 101: Intro to Dispersion Modeling Programs and Process Carolinas Air Pollution Control Association Presentation by: Pilar Johansson Trinity Consultants 2 Presentation Outline When are Models
More informationConnacht Gold. Reg No : PO th May Dairy Ingredients. 30,205 Nm3/hr Uncorrected for 02/ Wet. Dear Eve.
Connacht Gold Dairy Ingredients Shannonside Milk Products Ltd., Ballaghaderreen, Co. Roscommon, Ireland. tel: +353 (0) 94 98601 14 fax: +353 (0) 94 9860 7 57 em ail: shannonside0cgold. ie www.connach tgold.ie
More informationCritical Review of the Building Downwash Algorithms in AERMOD
Critical Review of the Building Downwash Algorithms in AERMOD Paper #34 Presented at the conference: Guideline on Air Quality Models: The New Path April 12-14, 2016 Chapel Hill, NC Ron L. Petersen, 1 Sergio
More informationAttachment 2. Modeling Protocol for Duke Energy Carolinas, LLC Belews Creek Steam Station
Attachment 2 Modeling Protocol for Duke Energy Carolinas, LLC Belews Creek Steam Station Duke Energy Belews Creek Generating Station Modeling Protocol For 1-hour SO 2 National Ambient Air Quality Standard
More informationJustifying a GEP Stack Height Taller than the EPA Formula Height
Justifying a GEP Stack Height Taller than the EPA Formula Height Paper # 415 Ronald L. Petersen, Ph.D., CCM, Anke Beyer-Lout CPP, Inc., 2400 Midpoint Drive, Suite 190, Fort Collins, CO 80525, rpetersen@cppwind.com
More informationCase study on pollution prediction through atmospheric dispersion modelling
Case study on pollution prediction through atmospheric dispersion modelling MIHAIELLA CRETU, VICTORIA TELEABA, SILVIU IONESCU, ADINA IONESCU Acoustics and Air Quality Laboratory COMOTI Romanian Research
More informationNational Ambient Air Quality Standards
Modeling Issues with the New National Ambient Air Quality Standards James Red Oris Solutions / BEE-Line Software Presented to North Texas Chapter of the Air & Waste Management Association August 24, 2010
More informationISSUES RELATED TO NO2 NAAQS MODELING
ISSUES RELATED TO NO2 NAAQS MODELING Presented to North Texas Chapter of the Air & Waste Management Association By James Red Providence Engineering and Environmental November 17, 2015 1 OUTLINE Overview
More informationTECHNICAL REPORT. For inspection purposes only. FOR. Vitra Tiles (Ireland) Ltd IDA Business Park Ballynattin Arklow
The Tecpro Building, Clonshaugh Business and Technology Park, Dublin 17 Tel: +353 (0)1 847 4220 Fax: +353 (0)1 847 4257 TECHNICAL REPORT DETERMINATION OF EMISSIONS TO ATMOSPHERE FROM THE VITRA TILES FACILITY,
More informationAIR WATER WASTE CONSULTANTS. Audit of TCEQ s Air Dispersion Modeling Prepared in Support of Proposed OGS Permit By Rule and Standard Permit
S OURCE ENVIRONMENTAL SCIENCES, INC. AIR WATER WASTE CONSULTANTS 4100 WESTHEIMER, SUITE 106 HOUSTON, TEXAS 77027-4427 source@source-environmental.com Phone: (713) 621-4474 Fax: (713) 621-4588 September
More informationAPPENDIX D MODELING AND DEPOSITION ANALYSIS
APPENDIX D MODELING AND DEPOSITION ANALYSIS Appendix D Ambient Air Quality Dispersion and Deposition Modeling Analyses Supporting a Permit to Install Application Eagle Project Located in Michigamme Township,
More informationGLNG PROJECT - ENVIRONMENTAL IMPACT STATEMENT
6 J:\Jobs\42626220\07 Deliverables\EIS\FINAL for Public Release\6. Values and Management of Impacts\6-8 Air Quality\06 08 Air Quality (Section 6.8) FINAL PUBLIC track.doc GLNG Project - Environmental Impact
More informationAERMOD Modeling of SO2 Impacts of the Luminant Martin Lake Coal Plant
AERMOD Modeling of SO2 Impacts of the Luminant Martin Lake Coal Plant Final Report June 2011 Prepared for Sierra Club San Francisco, California Prepared by Mr. Khanh T. Tran Principal AMI Environmental
More informationAir Quality Assessment: Queen Margaret University Biomass Boiler. Report to East Lothian Council
Air Quality Assessment: Queen Margaret University Biomass Boiler Report to East Lothian Council Unrestricted October 2010 Title Customer Customer reference Confidentiality, copyright and reproduction File
More information75th Air Base Wing. Comparison of CALPUFF and OBODM for Open Burn/Open Detonation Modeling. 22 May Mark Bennett, Ph.D.
75th Air Base Wing Comparison of CALPUFF and OBODM for Open Burn/Open Detonation Modeling 22 May 2007 Mark Bennett, Ph.D. CH2M Hill, Inc Joint Services Environmental Management Conference and Exposition
More informationAir pollution modeling of the industrial complexes and cities in the Kurdistan region using AERMOD view
First International Symposium on Urban Development: Koya as a Case Study 333 Air pollution modeling of the industrial complexes and cities in the Kurdistan region using AERMOD view H. Moradi 1,2, M. Rouhi
More informationExcerpt of Thermal Power Guidelines for New Plants
Excerpt of Thermal Power Guidelines for New Plants The following is an excerpt of the Thermal Power guidelines for New Plants, a complete version of which is found in the Pollution Prevention and Abatement
More informationRULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION BUREAU OF ENVIRONMENT DIVISION OF AIR POLLUTION CONTROL
RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION BUREAU OF ENVIRONMENT DIVISION OF AIR POLLUTION CONTROL CHAPTER 1200-3-24 GOOD ENGINEERING PRACTICE TABLE OF CONTENTS 1200-3-24-.01 General
More informationMolar Ratio Method (PVMRM) and Ozone Limiting Method (OLM) for Predicting Short-term NO 2 Impacts
Review of Plume Volume Molar Ratio Method (PVMRM) and Ozone Limiting Method (OLM) for Predicting Short-term NO 2 Impacts Elizabeth Hendrick, CCM Vincent Tino, CCM Dr. Bruce Egan, CCM Dr. Steven Hanna,
More informationAIR QUALITY IMPACT ASSESSMENT SPARTA HOLDING (PTY) LTD WELKOM OPERATIONS FINAL REPORT AUGUST 2016
AIR QUALITY IMPACT ASSESSMENT Prepared for SPARTA HOLDING (PTY) LTD WELKOM OPERATIONS FINAL REPORT AUGUST 2016 Lethabo Air Quality Specialists cc PO Box 2174 Noorsekloof 6331 SPARTA AQI Page 1 of 33 August
More informationDispersion Modeling of NO x and SO x in Phase 9 and 10 of South Pars Oilfield
Dispersion Modeling of NO x and SO x in Phase 9 and 10 of South Pars Oilfield Maryam Rouhi 1, Hossein Moradi 2, Alireza Soffianian 3, Alireza Dahaghin 4 1 Master student of Environmental Sciences E-mail:
More informationPrepared for: Toronto Hydro Energy Services Inc. 14 Carlton Street Toronto, Ontario M5B 1K5. Prepared by:
EMISSION SUMMARY AND DISPERSION MODELLING REPORT GREEN LANE LANDFILL GAS COGENERATION PLANT TORONTO HYDRO ENERGY SERVICES INC. 38024 JOHN WISE LINE, TOWNSHIP OF SOUTHWOLD, ONTARIO Prepared for: Toronto
More informationAIR DISPERSION MODELLING IN COASTAL AREAS WITH ROUGH TERRAIN, USING CALPUFF PRIME
AIR DISPERSION MODELLING IN COASTAL AREAS WITH ROUGH TERRAIN, USING CALPUFF PRIME Marcia C. Parsons, Fracflow Consultants Inc., 154 Major s Path, St. John s, NL, Canada, A1A 5A1, Faisal Khan, Memorial
More informationAir Dispersion Model Report. For. Boylan Group Ltd.
Appendix E: Air Dispersion Model Air Dispersion Model Report For Ltd. (Document no: 632-07) Environmental Efficiency 97 QF 1. v2 Document Lead Sheet Document Title Air Dispersion Model for Project No.
More informationAir Dispersion Modeling Guidelines for Arizona Air Quality Permits
Air Dispersion Modeling Guidelines for Arizona Air Quality Permits PREPARED BY: AIR ASSESSMENT SECTION AIR QUALITY DIVISION ARIZONA DEPARTMENT OF ENVIRONMENTAL QUALITY December 2004 TABLE OF CONTENTS Section
More informationComparison of Features and Data Requirements among the CALPUFF, AERMOD, and ADMS Models
Comparison of Features and Data Requirements among the CALPUFF, AERMOD, and ADMS Models Prepared By: Russell F. Lee BREEZE SOFTWARE 12700 Park Central Drive Suite 2100 Dallas, TX 75251 +1 (972) 661-8881
More informationIntermodal Logistics Centre at Enfield Environmental Assessment CHAPTER 12 AIR QUALITY ASSESSMENT
Intermodal Logistics Centre at Enfield Environmental Assessment CHAPTER 12 AIR QUALITY ASSESSMENT October 2005 Contents 12. 12-1 12.1 Introduction 12-1 12.2 Factors Affecting Air Quality 12-1 12.3 Air
More informationInfluence of building-downwash effect on urban traffic pollution
Influence of building-downwash effect on urban traffic pollution G. Latini, G. Passerini & S. Tascini Dipartimento di Energetica, Università Politecnica delle Marche, Italy Abstract Building-downwash has
More informationAppendix 14.2 Air Quality Modelling Study
Appendix 14.2 Air Quality Modelling Study Volume 3: Environmental Statement Further Information Report Appendices Brent Cross Cricklewood: Phase 1B (North) FIR N:\Projects\WIE11453\100\8_Reports\2. ES\Volume
More informationClean TeQ Sunrise CCC meeting
Clean TeQ Sunrise CCC meeting 15 February 2018 AGENDA General update Modification 4 Overview / update Transport assessment Clean TeQ s submission Modification 6 Working with and investing in our community
More informationAIR POLLUTANT DISPERSION. EXAMPLE APPLICATION TO AN AIRPORT AIR QUALITY MANAGEMENT SYSTEM.
EUROPEAN UNION GOVERNMENT OF ROMANIA GOVERNMENT OF THE REPUBLIC OF SERBIA Structural Funds 2007-2013 AIR POLLUTANT DISPERSION. EXAMPLE APPLICATION TO AN AIRPORT AIR QUALITY MANAGEMENT SYSTEM. Assoc.prof.dr.ing.
More informationSignificance of a CALPUFF Near-Field Analysis
Significance of a CALPUFF Near-Field Analysis Paper #70052 Authors: Elizabeth A. H. Carper Trinity Consultants 20819 72 nd Avenue South, Suite 610 Kent, WA 98032 Eri Ottersburg Trinity Consultants 20819
More informationMODELING METHODOLOGY
Paul Schleusener, Senior Engineer Specialist Michigan Department of Environmental Quality Air Quality Division Constitution Hall, 1 st Floor 525 West Allegan Street P.O. Box 30473 Lansing, MI 48909 7973
More informationPrepared for: Toronto Hydro Energy Services Inc. 14 Carlton Street Toronto, Ontario M5B 1K5. Prepared by:
EMISSION SUMMARY AND DISPERSION MODELLING REPORT IN SUPPORT OF A RENEWABLE ENERGY APPROVAL APPLICATION TORONTO HYDRO ENERGY SERVICES INC. LESLIE ST., TORONTO, ONTARIO Prepared for: Toronto Hydro Energy
More information1 Introduction What is Dispersion Modelling What can dispersion modelling be used for? What can t dispersion models do?...
Table of Contents 1 Introduction 3 1.1 What is Dispersion Modelling... 4 1.2 What can dispersion modelling be used for?... 4 1.3 What can t dispersion models do?... 5 2 Why is dispersion modelling required?
More informationModelling the effects of traffic emissions on the air quality
Air Pollution XIII 49 Modelling the effects of traffic emissions on the air quality G. Genon & E. Brizio Turin Polytechnic, Italy Abstract European directives 1999/30/CE and 2000/69/CE set severe limits
More informationAssessing the air quality, toxic and health impacts of the Lamu coal-fired power plants
Assessing the air quality, toxic and health impacts of the Lamu coal-fired power plants Lauri Myllyvirta 1 & Clifford Chuwah 2 Greenpeace Research Laboratories 3 Technical Report 06-2017 June 2017 Summary
More informationComparative Use of ISCST3, ISC-PRIME and AERMOD in Air Toxics Risk Assessment
Comparative Use of ISCST3, ISC-PRIME and AERMOD in Air Toxics Risk Assessment KHANH T. TRAN Applied Modeling Inc., 21395 Castillo Street, Woodland Hills, CA 91364 Telephone (818) 716-5347, E-mail: kttran@amiace.com,
More informationAIR DISPERSION MODELING
Click to edit Master title style AIR DISPERSION MODELING Use of AERMOD for NAAQS Area Designations and State Implementation Plan Submittals SPEAKER Stewart McCollam DATE February 10, 2016 USE OF AERMOD
More informationAppendix 0 Air Dispersion Modelling Study Black Point Quarry Project Guysborough County, NS SLR Project No.:
Appendix 0 Air Dispersion Modelling Study 2015 Black Point Quarry Project Guysborough County, NS SLR Project No.: 210.05913.00000 Black Point Quarry Air Dispersion Modelling Study Prepared for: CJ Spainhour
More informationSO 2 Air Dispersion Modeling Report for White Bluff Steam Electric Station. ERM Project No The world s leading sustainability consultancy
SO 2 Air Dispersion Modeling Report for White Bluff Steam Electric Station August 2015 ERM Project No. 0268066 www.erm.com The world s leading sustainability consultancy SO 2 Air Dispersion Modeling Report
More informationAIR AND ODOUR EMISSIONS ASSESSMENT OF OPERATIONAL SHUTDOWN STACK RELEASE
AIR AND ODOUR EMISSIONS ASSESSMENT OF OPERATIONAL SHUTDOWN STACK RELEASE CLEAN HARBORS CANADA INC. CORUNNA, ONTARIO DISCLAIMER: SOME FORMATTING CHANGES MAY HAVE OCCURRED WHEN THE ORIGINAL DOCUMENT WAS
More information10.0 AIR QUALITY AND CLIMATIC FACTORS
.0 AIR QUALITY AND CLIMATIC FACTORS.1 ASSESSMENT METHODOLOGY.1.1 General Section 39 (2) (b) (ii) of the Transport (Railway Infrastructure) Act 2001, requires that proposed developments are examined in
More informationMULTIPLE POINT SOURCE DISPERSION ANALYSIS OF CO, NO 2, PM 10 AND SO 2 FROM PAITON POWER PLANT USING CALPUFF
International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 1, January 2018, pp. 837 846, Article ID: IJCIET_09_01_081 Available online at http://http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=1
More informationAtmospheric Dispersion Modelling for Odour Impact: Practices, Issues & Recommendations
Atmospheric Dispersion Modelling for Odour Impact: Practices, Issues & Recommendations Chris Scullion, Managing Consultant September 14-15, 2015 Toronto, ON trinityconsultants.com Odour Dispersion Modelling
More informationEvaluation of CO and NO x Distributions from Point (Industry) Sources in Körfez District of Kocaeli Province with ISCST3 Model
Digital Proceeding Of THE ICOEST 2013 -, Cappadocia C.Ozdemir, S. Şahinkaya, E. Kalıpcı, M.K. Oden (editors) Nevsehir, Turkey, June 18 21, 2013 Evaluation of CO and NO x Distributions from Point (Industry)
More informationDetailed Air Quality Modelling and Analysis
Page 1 of 22 Ser. No. Via San Gregorio, 38 20124 Milan - Italy IAL00-ERM-643-Y-TAE-1021 Proponent: Author: Project Title: Trans Adriatic Pipeline AG Environmental Resources Management Trans Adriatic Pipeline
More informationMetropolitan Transit. Prepared for. Original Submittal: May 28, Resubmitted: November 10, 2010 January 21, aq5-28
Criteria Pollutant Air Dispersion Modeling Analysis for Metro Transit s Existing Hiawatha Light Rail Vehicle Operation & Maintenance Facility, Proposed Paint Booth, and Proposed Light Rail Support Facility
More informationAir Quality Assessment Report Paris Grand Development County of Brant, Ontario
Air Quality Assessment Report Paris Grand Development County of Brant, Ontario Novus Reference No. 16-0214 NOVUS TEAM: Technical Coordinator: Air Quality Engineer: Project Director: Laura Clark, B.Eng.,
More informationArab Journal of Nuclear Sciences and Applications
Arab J. Nucl. Sci. Appl, Vol 51, 2, 68-81 (2018) Arab Journal of Nuclear Sciences and Applications ISSN 1110-0451 Web site: ajnsa.journals.ekb.eg (ESNSA) Environmental Impact of Conventional Power Plant
More informationIntroduction to Air Quality Models
Introduction to Air Quality Models Emission Model Meteorological Model Temporal and spatial emission rates Topography Chemical Transformation Pollutant Transport Equilibrium between Particles and gases
More informationAERMOD Modeling of PM2.5 Impacts of the Proposed Highwood Generating Station
AERMOD Modeling of PM2.5 Impacts of the Proposed Highwood Generating Station September 10, 2007 Prepared for Montana Environmental Information Center and Citizens for Clean Energy Prepared by Khanh T.
More informationCarbery Group. Primary Fuel Switch Proposal. Ambient Air Pollution Impact For inspection purposes only.
Carbery Group Primary Fuel Switch Proposal Ambient Air Pollution Impact CARBERY GROUP Ref: 0005_3 Carbery Group Primary Fuel Switch Proposal Ambient Air Pollution Impact Prepared by: Andrew Shepherd BSc
More informationEMISSION SUMMARY AND DISPERSION MODELLING REPORT
1 EMISSION SUMMARY AND DISPERSION MODELLING REPORT Interior Heart and Surgical Centre Project (IHSC) Kelowna General Hospital Kelowna, British Columbia Prepared for PCL Constructors Westcoast Inc. Report
More informationReview of GHD s Modeling Assessment and Analysis of the Coal-fired Power Stations in the Latrobe Valley. Dr. H. Andrew Gray Gray Sky Solutions
Review of GHD s Modeling Assessment and Analysis of the Coal-fired Power Stations in the Latrobe Valley Dr. H. Andrew Gray Gray Sky Solutions September 19, 2018 1 Introduction My name is Dr. H. Andrew
More informationWaterview Operational Air Quality Monitoring Report January 2018
Waterview Operational Air Quality Monitoring Report January 2018 Document No: [Subject] Waterview Tunnel Joint Operation nzta.govt.nz/waterviewconnection 1399 Great North Road, Waterview, Auckland 1026
More informationPlanning or Diagnostic Tool. Air Plume Modeling. Michael Gemelli, Lockheed-Martin/REAC, Edison, NJ. Keith Ocheski, Lockheed-Martin/REAC, Edison, NJ
Air Plume Modeling Planning or Diagnostic Tool Rod Turpin, US EPA-ERT, Edison, NJ Greg De Angelis, US EPA Region II, Edison, NJ Paul Groulx, US EPA Region I, Boston, MA And Keith Ocheski, Lockheed-Martin/REAC,
More informationModelling of air pollutants released from highway traffic in Hungary
Air Pollution XVI 77 Modelling of air pollutants released from highway traffic in Hungary Gy. Baranka Hungarian Meteorological Service, Hungary Abstract The aim of study is to determine the CO and NO 2
More informationGUIDELINES FOR EVALUATING THE AIR QUALITY IMPACTS OF TOXIC POLLUTANTS IN NORTH CAROLINA
GUIDELINES FOR EVALUATING THE AIR QUALITY IMPACTS OF TOXIC POLLUTANTS IN NORTH CAROLINA February 2014 North Carolina Department of Environment and Natural Resources Division of Air Quality Permitting Section
More informationAtmospheric Air Pollutant
Atmospheric Air Pollutant Atmospheric Stability Dispersion Estimate air pollutant concentrations downwind of emission point sources. Downwind Air Pollution Concentrations Are a function of: Air Temperature
More informationIs AERMOD/PRIME Overpredicting for Short Buildings with a Large Footprint?
Is AERMOD/PRIME Overpredicting for Short Buildings with a Large Footprint? Paper # 517 102 nd Annual Conference and Exhibition of the Air & Waste Management Association Detroit, June 2009 Ronald L. Petersen
More informationReview of the 2009 Gauteng Air Quality Management Plan
Review of the 2009 Gauteng Air Quality Management Plan GT/GDARD/154/2016 DISPERSION MODELLING PLAN OF STUDY To: From: Gauteng Provincial Treasury Imbumba House 75 Fox Street Marshalltown, Johannesburg
More informationSensitivity of AERMOD to Meteorological Data Sets Based on Varying Surface Roughness. Paper No A-168-AWMA
Sensitivity of AERMOD to Meteorological Data Sets Based on Varying Surface Roughness Paper No. 2009-A-168-AWMA Prepared by: Anthony J. Schroeder, CCM Senior Consultant George J. Schewe, CCM, QEP Principal
More information47.0 GOOD ENGINEERING PRACTICE STACK HEIGHT
47.0 GOOD ENGINEERING PRACTICE STACK HEIGHT 47.1 General Provisions A. This section provides that the degree of emission limitation required of any source for control of any air pollutant must not be affected
More informationAir Quality Modelling. Table of Contents
Table of Contents 1.0 Introduction... 5 1.1 Purpose of Modeling... 5 1.2 Phases of a Modeling Study... 5 1.2.1 Scoping Phase... 6 1.2.2 Screening Model Phase... 6 1.2.3 Refined Model Phase... 6 1.2.4 Presentation
More informationRoss Nogami Air Quality Studies Hayashi Court Richmond, B.C. V7E 5W2
Ross Nogami Air Quality Studies 12300 Hayashi Court Richmond, B.C. V7E 5W2 Mr. Casey Houweling President 2776 64 th Street Delta, B.C. V4L 2N7 Dear : Re: Predicted Ambient Air Quality from a Dispersion
More informationImproved Building Dimension Inputs for AERMOD Modeling of the Mirant Potomac River Generating Station
Improved Building Dimension Inputs for AERMOD Modeling of the Mirant Potomac River Generating Station Paper # 276 Ronald Petersen and Jeff Reifschneider CPP, Inc., 1415 Blue Spruce Drive, Fort Collins,
More informationEnergy Impact Analysis in Support of Class I Redesignation Requests. Prepared for. Fond du Lac Band of Lake Superior Chippewa Cloquet, Minnesota
Energy Impact Analysis in Support of Class I Redesignation Requests Prepared for Fond du Lac Band of Lake Superior Chippewa Cloquet, Minnesota Prepared by August 2011 TABLE OF CONTENTS Section Page 1.0
More informationSTUDY OF IMPACT OF DISPERSION OF GASES FROM STACK ON ENVIRONMENT THROUGH CFD SIMULATION. By Shashi Shekhar (111CH0405)
STUDY OF IMPACT OF DISPERSION OF GASES FROM STACK ON ENVIRONMENT THROUGH CFD SIMULATION A THESIS SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF Bachelor of Technology In Chemical
More informationLocalized Significance Threshold Analysis
Localized Significance Threshold Analysis ANDORA AVENUE SUBDIVISION Tentative Tract No. 53426 Subsequent EIR Localized Significance Threshold Analysis Prepared for: City of Los Angeles, Department of City
More informationAIR QUALITY ASSESSMENT RICHARD ATHERTON MANCHESTER ROAD, RAMSBOTTOM, BURY REPORT DATE: 14TH JUNE 2016 REPORT NUMBER: on behalf of.
AIR QUALITY ASSESSMENT on behalf of RICHARD ATHERTON for MANCHESTER ROAD, RAMSBOTTOM, BURY REPORT DATE: 14TH JUNE 2016 REPORT NUMBER: 101289 Miller Goodall Ltd Ground Floor Ashworth House Deakins Business
More informationWelcome to the H1 Software
Welcome H1 Version Welcome to the H1 Software 2.01- May 2010 Introduction This version of the tool accompanies Horizontal Guidnace Note 1 Version 2.0 April 2010 (As Amended) Important Notes: This software
More informationAPPENDIX E SATURN (UNITS 1 & 2) AIR TDR
APPENDIX E SATURN (UNITS 1 & 2) AIR TDR Technical Data Report for Saturn Compressor Station (Units 1&2) Air Quality Prepared for: NOVA Gas Transmission Ltd. Calgary, Alberta Prepared by: Stantec Consulting
More informationTechnical Guidance Document for Air Quality Modeling
Technical Guidance Document for Air Quality Modeling EAD-EQ-PCE-TG-12 Signature on Original Environment Quality Sector * Corporate Management Representative Secretary General Originated By Reviewed By
More informationPrepared for: Toronto Hydro Energy Services Inc. 14 Carlton Street Toronto, Ontario M5B 1K5. Prepared by:
EMISSION SUMMARY AND DISPERSION MODELLING REPORT IN SUPPORT OF A RENEWABLE ENERGY APPROVAL APPLICATION TORONTO HYDRO ENERGY SERVICES INC. LESLIE ST., TORONTO, ONTARIO Prepared for: Toronto Hydro Energy
More informationDETERMINATION OF ODOUR EMISSIONS TO ATMOSPHERE FROM THE MATER HOSPITAL, DUBLIN 1
DETERMINATION OF ODOUR EMISSIONS TO ATMOSPHERE FROM THE MATER HOSPITAL, DUBLIN 1 Technical Report Prepared For Tobin Consulting Engineers, Block 10-4, Blanchardstown Corporate Park, Dublin 15. Technical
More informationDISPERSION MODEL GUIDELINES FOR OIL BATTERIES IN THE PROVINCE OF MANITOBA. Project Number: W Date: February 15, 2002
DISPERSION MODEL GUIDELINES FOR OIL BATTERIES IN THE PROVINCE OF MANITOBA Project Number: 02-215W Date: February 15, 2002 Submitted By: RWDI West Inc. Principal Meteorologist - Mervyn J.E. Davies, M.Sc.
More information