CHEMICAL INJECTION METHODS Pros & Cons
|
|
- Stella Perry
- 6 years ago
- Views:
Transcription
1 CHEMICAL INJECTION METHODS Pros & Cons 1
2 Chemical injection is an integral component of any pipeline integrity program. The petroleum, chemical, and water treatment industries require chemical treatments to control various undesirable contaminants and prevent asset degradation. Some of the chemicals typically injected are corrosion, scale, and paraffin inhibitors; hydrogen sulfide, carbon dioxide and oxygen scavengers; biocides; glycols and methanol. Careful consideration of the injection method chosen will provide a cost effective and reliable solution. Criteria required to select the proper chemical injection method: 1) The treatment required and chemical selected 2) Process conditions a. Process Fluid (i.e. natural gas, crude oil, water, etc.) b. Pressure (min-normal-max) c. Temperature (min-normal-max) d. Flow rate (min-normal-max) e. Process density 3) Chemical density relative to water 4) Injection site specifics a. Pipeline diameter or vessel size b. Injection port size and type c. Utilities to power pump 2
3 A typical chemical injection system: 1) Chemical bulk tank constructed of materials compatible with the chemical and sized adequately to minimize refilling 2) Spill containment reservoir sized to hold times the storage tank contents 3) Chemical strainer/filter (80 mesh) for larger particulate removal 4) Gauge to set the pump discharge rate 5) A positive displacement pump capable of pumping pressures well above maximum process pressure; *materials of construction compatible with the chemical A. Diaphragm or piston actuated pneumatic a. Natural gas instrument supply requires instrument supply regulator, filter dryer, and lubricator. b. Instrument air supply B. Electric motor actuated a. 240 VAC or 120 VAC supply must consider electrical area classification b. 12 VDC solar and battery sized for winter temperatures and lack of sunshine 6) Pump discharge pulsation dampener constructed of materials compatible with chemical 7) Nipple, quill, or atomizer with 50 micron inlet filter, check valve, pressure gauge, and isolation valve *An adjustable relief should be plumbed from the pump discharge to the pump suction for over pressure protection. 3
4 4
5 Characteristics of Various Chemical Treatments: 1) H2S, O2, and CO2 scavengers* A. Densities similar to water and must be dispersed and distributed thoroughly within the process media for maximum contact time. B. Requires continuous direct injection distributed via an atomizer. 4) Corrosion inhibitors * A. Density similar or slightly heavier than water and is applied to the interior wall of the pipeline or vessel. B. Requires continuous or batch injection distributed via a nipple with check valve. 5) Paraffin inhibitors in crude oil A. Densities slightly lighter than water and must be dispersed and distributed thoroughly within the process media for maximum contact time. B. Requires continuous or batch injection distributed via a quill with check valve. Static mixers may be considered if pressure drop can be tolerated. 4) Glycols A. Density slightly heavier than water and is applied to the interior wall of the pipeline or vessel. B. Requires continuous or batch injection distributed via a quill with check valve. 5) Methanols A. Densities slightly less than water and must be dispersed and distributed thoroughly within the process media for maximum contact time. B. Requires continuous direct injection distributed via an atomizer. * Injection quills should be used when distributing chemical in a liquid media. 5
6 There are numerous pump styles available, but they all have common components. 1) Actuation Motor A. Pneumatic a. Natural Gas b. Instrument air B. Electric a. 240 VAC or 120 VAC (Area Class) b. 24 VDC Batteries with Solar Panel 2) Pump a. Piston b. Plunger d. Diaphragm e. Bellows 3) Packing/Seals compatible with chemical 4) Air Bleeders 5) Inlet and Outlet Check Valves 6) Rate Adjustment a. Stroke Length b. Timer 6
7 Information required to choose the correct pump: 1) Size the pump for the full range of injection rates required. 2) Size the pump for discharge pressures well above process pressures plus any restrictions within the chemical injection system. Example: Process pressure of 800 psi and spring loaded nozzle cracking pressure of 425 psi. The pump must be capable of pumping pressure s above 1225 psi. 3) Method of pump actuation a. Clean dry instrument supply gas a. Natural Gas (consider emissions, poor gas quality) b. 240/120 VAC Electric (subject to power outages) c. 24 VDC solar and battery (consider lack of sunshine, battery disposal) 4) Durability a. Materials of construction must be compatible with the chemical. b. Undersized pumps must be stroked at their maximum range. 7
8 Pulsation dampeners are a valuable addition to any well-designed chemical injection system. Pulsation dampeners are used to decrease pressure spikes in the pump discharge as well as becoming a secondary pump. The pulsation dampener contains compressed stored energy which discharges with the back stroke of the pump. Ultimately, the pump stroke time can be slowed down reducing valuable wear and tear. The bladder style pulsation dampener is better suited to the challenges of a continuous pipeline injection system. 8
9 Choosing the appropriate chemical distribution method. 1) Is the process fluid a gas or liquid? A. Gas a. Requires an insertable atomizer for most chemicals.* b. Quill can be used if velocity is greater than 15 ft/second. c. Nipple with check valve should be used for corrosion inhibitors. B. Liquid a. Requires an injection quill for most chemicals.* 2) Does the chemical require distribution and dispersion for maximum contact throughout the process fluid? a. Requires an insertable atomizer.* 3) Is the chemical required to coat the pipeline or vessel walls? a. Requires a nipple and check valve. 4) Is the chemical required to target a specific undesirable with a specific location within the pipeline of vessel (i.e. water in crude oil)? a. Requires a quill to the bottom of the pipe or a bottom injection with a nipple and check valve.* *Insertable probes within a liquid process and a gas process with excessive velocity are susceptible to bending and frequency oscillations which may cause stress failures. Probe stress calculations are suggested when in doubt. 9
10 Choosing the appropriate chemical distribution method (part 2). 1) What are the design and operating pressures and temperatures? A. Can a hand insertable atomizer or quill be used? B. Is a mechanically insertable atomizer or quill required? 2) What is the process fluid velocity and density? Is a probe stress calculation required? Need process velocity, density, and temperature. 3) What is the pipeline diameter or vessel size? What is the insertion length required to injection zone? 4) What is the access port size and type? A. If insertable atomizer or quill is desired a full port process isolation ball valve is required. Ball valve size and type connection (i.e. 1/2-2 NPT or flanged) B. If fixed quill is desired. Size and type of port (i.e. 1/2-2 NPT or flanged) 10
11 11
12 The nozzle is the key component of an injection atomizer. Sizing and selection is based on several factors. 1) Injection rates (min-max) 2) Density of chemical 3) Pump discharge pressure capability 4) Process pressures (min max) A 50 micron filter, check valve, and pressure gauge is a must when using an atomization nozzle. 12
13 Conclusion Chemical injection is not merely an after thought. Rather, it takes considerable planning for a safe, reliable, and efficient system! 13
Energy Transfer in a Hydraulic System. Lecture (1) Hydraulic and Pneumatic Circuits 4th year Mech. power Engineering Dept.
15 Energy Transfer in a Hydraulic System 16 Control in a Hydraulic System The signal control section The power control section Drive section Signal input Signal processing Power control section Power flow
More informationCustomised Gasifier Feed Pumps. Daniel M. Nägel FELUWA Pumpen GmbH
Customised Gasifier Feed Pumps Daniel M. Nägel FELUWA Pumpen GmbH Naegeld@feluwa.de Hydrostatic displacement Pumps Oscillating Pumping Characteristic Piston Pump The conveyed fluid is in contact with sliding
More informationEquipment Catalog. For inquiries and orders, please contact:
Equipment Catalog 1 2 Table of contents...pages Force Flow 100 Lube Pump... 4 Bucket Pumps... 5 Packing Injection Fitting Body Vent (Bleeder) Fittings... 6 1200 & 1500 Lube Pumps... 7 Hose Assemblies Gages
More informationReduction in chemical inhibitor feed starts saving you money almost immediately
Chemical Injection and Corrosion Monitoring go hand in hand and are vital to defend against the devastating effects of corrosion in regards to safety and asset life. Knowing when and how much chemicals
More informationWHY EFFICIENCY IS PARAMOUNT FOR OFFSHORE PRODUCTION
WHY EFFICIENCY IS PARAMOUNT FOR OFFSHORE PRODUCTION HOW INNOVATIVE BREAKTHROUGHS WITH PTFE DIAPHRAGMS HAVE PRODUCED SMALLER AND LIGHTER METERING PUMPS WITHOUT COMPROMISING ON PERFORMANCE Pulsafeeder, Inc.
More informationQuality First! Independent Water Pumping Systems. SDSP Submersible Sump Pump
Quality First! TM SOLAR PUMPING PRODUCTS Independent Water Pumping Systems SDS Series Submersible Pumps SunPumps SDS series submersible pumps are highly efficient, low voltage, DC powered, diaphragm type
More informationAir-Operated Double Diaphragm Pumps
Air-Operated Double Diaphragm Pumps FIRST IN QUALITY Total Quality Management is ingrained in the Iwaki Air brand of Air-Operated Double Diaphragm (AODD) pumps, which are manufactured under stringent ISO
More informationPISTON BALANCED THROTTLING
Repair Manual PISTON BALANCED THROTTLING PISTON BALANCED THROTTLING REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Repair Kit Contents... 3 Disassembly: Topworks Pressure Opens... 5 Disassembly:
More informationCapillary Injection Tubing Anchor Technologies
Capillary Injection Tubing Anchor Technologies Patent Pending Randy Matthews- Weatherford Shad Frazier- SandRidge Energy ABSTRACT There are many oil and gas fields across the United States which have been
More informationObsolete. Description. Rhinor SD2/XD2 Type-H Follower Modules
Description See Figure. The Type-H follower module attaches onto the hydraulic section of the pump (). It is designed to force material out of straight-sided containers. Type-H follower plate modules are
More informationNessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100
Data Sheet Nessie Pumps type PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 Introduction PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 are pumps designed to supply water
More informationHandling Fluid Fertilizers Selecting the Right Equipment Components
Handling Fluid Fertilizers Selecting the Right Equipment Components 9/2/2010 1 Considerations Systematic approach Compatible components Short term vs. long term Plan ahead for future expansion 9/2/2010
More informationCopyright 2004 and 2005 by The American Institute of Architects (AIA)
Page 232500-1 Copyright 2004 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical
More informationH 2 S Treating Options and Factors Influencing Decisions. June 30, 2016
H 2 S Treating Options and Factors Influencing Decisions June 30, 2016 Agenda Calculation for lbs. of sulfur per day Factors affecting scavenge rates Treating applications and chemistries Pros/cons each
More informationAIR BLEED VALVES : ST1004 PIPE FLANGE KITS : "F3","F5","F6" SERIES
AIR BD VAVS : ST04 PIP ANG ITS : "3","5","6" SRIS General Information Pub. C-0 Air Bleed Valves...Page These air bleed valves are designed to use, at the start-up of the pumps, to bleed off the air enclosed
More informationPAHT C pumps ATEX PAHT C pump
MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet ATEX PAHT C pump hpp.danfoss.com Table of Contents 1. Introduction...2 2.
More informationSeal-less Pump Technology. Oil and Gas. Robust design - Reliability
Seal-less Pump Technology Oil and Gas Robust design - Reliability Hydra-Cell Oil and Gas Industry Pumps Compact seal-less pumps for long life and high reliability Gas Drying Pumping hot TEG With over 35
More informationWHY INTERNAL CORROSION MONITORING
Corrosion is one of the most serious ageing mechanism impacting the equipment and assets of process facilities in oil and gas industry. Uncontrolled corrosion can lead to severe safety and environmental
More informationHow do you reconcile PROCESS
Advantage Hydra-Cell Pumps The importance of pumps in the world of chemical processing and manufacture is self-evident. Many processes cannot run without them. The cost of pump failure in downtime and
More informationSpecifications. 304 Stainless Steel Mesh Screen. Specifications
Sample Intelligence SAMPLE CONDITIONING SAMPLE CONDITIONING HEATED SYSTEM SCHS The Welker SCHS properly conditions a flowing gas stream and protects analyzers from free liquids. A proven trio of liquid
More informationStatic Mixers. Operation, Installation and Maintenance Instructions. Custom Engineered Solutions. to Meet Your Specific Industry Needs
Custom Engineered Solutions to Meet Your Specific Industry Needs Static Mixers Operation, Installation and Maintenance Instructions Custom Engineered Solutions Theory of Operation JDMIX static mixers uniformly
More informationLUBRICATION PUMP Z2 CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated
More informationCOMPRESSED AIR SYSTEM DESIGNS BEGIN WITH THE DEMANDS
COMPRESSED AIR SYSTEM DESIGNS BEGIN WITH THE DEMANDS BY: BILL SCALES, P.E. SCALES INDUSTRIAL TECHNOLOGIES, INC. The purpose of an assessment of an existing compressed air system, or design of a new one,
More informationfor TWISTER INSTRUMENTATION & PROCESS SOLUTIONS INC.
PRODUCT CATALOGUE for TWISTER INSTRUMENTATION & PROCESS SOLUTIONS INC. This product catalogue has been downloaded from COSSD.com. Listed products/services and their descriptions are shown as supplied by
More informationG E N E R A L C AT A L O G
G E N E R A L C AT A L O G C G 1 1 2 0 1 5 C O N T E N T Measurement High pressure Instrumentation Electronic devices Electromechanical Mechanical Transmission Diaphragm pumps Hydraulics Filtration Pneumatics
More informationPRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES
Master Pneumatic regulators are made in a wide range of sizes to suit nearly all industrial requirements for pneumatic pressure regulation. Good pressure regulation is essential to the efficient use of
More information12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS
TM 12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS The reliable pump people Performance Shown at 2000 PSID (138 BAR), 200 SSU (43 CST) 60 HZ: 870 1150 1750 3500 *Bi-metal construction only 50 HZ: 960 1450
More informationChemical Injection Methods for Irrigation 1
CIR864 1 Dorota Z. Haman and Fedro S. Zazueta 2 Methods of Chemical Injections Chemical application through irrigation systems is called chemigation. Chemigation has been practiced for many years especially
More informationSECTION HVAC WATER TREATMENT
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 25 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //-----// if not applicable to project. Also delete any other item or paragraph
More informationEnergy Efficient Compressed Air Systems Useful Practical Guide
Energy Efficient Compressed Air Systems Useful Practical Guide Contents 1 Introduction 2 Managing a compressed air system 3 Misuse and waste of compressed air 4 Air distribution network 5 Compressors,
More informationChemical Injection Methods for Irrigation 1
CIR864 Chemical Injection Methods for Irrigation 1 Dorota Z. Haman, Allen G. Smajstrla and Fedro S. Zazueta 2 METHODS OF CHEMICAL INJECTIONS Chemical application through irrigation systems is called chemigation.
More informationChemical Injection Methods for Irrigation 1
CIR864 Chemical Injection Methods for Irrigation 1 Dorota Z. Haman and Fedro S. Zazueta 2 METHODS OF CHEMICAL INJECTIONS Chemical application through irrigation systems is called chemigation. Chemigation
More informationWATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters
WATER FILTRATION EQUIPMENT Commercial Water Filters 7 TO 69 and Larger (Single, Twin, Triple or Quadruple systems) 1 P a g e LWF SERIES filtration equipment can be engineered to solve complex commercial
More informationNessie Pumps type PAH 2/4/6.3, 10/ /32 and PAH 50/63/70/80
Data Sheet Nessie Pumps type PAH 2/4/6.3, 10/12.5 25/32 and PAH 50/63/70/80 Generally PAH 2/4/6,3, 10/12,5, 25/32 and 50/63/70/80 are pumps designed to supply water flow under high pressure. The pumps
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationSECTION CHEMICAL FEED SYSTEM
SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary
More informationVERTICAL LEAF FILTERS. Passion for Filtration
VERTICAL LEAF FILTERS Passion for Filtration OVERVIEW Twin Filter Vertical Leaf Filters are high-quality systems that can be used for numerous batch and continuous filtration processes. The system consists
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More informationSeal-less Pump Technology. Oil and Gas. Robust design - Reliability
Seal-less Pump Technology Oil and Gas Robust design - Reliability Hydra-Cell Oil and Gas Industry Pumps Compact seal-less pumps for long life and high reliability Gas Drying Pumping hot TEG With over 35
More informationFERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS
IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer
More informationINDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series
INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment
More informationValve Nest Filter with Time Clock Control Installation and Operation Manual
Valve Nest Filter with Time Clock Control Installation and Operation Manual Effective 5/24/12 Effective 5/24/12 Table of Contents Operating Data. 1 Pre-Installation Data... 2 Filter Parameters Installation
More informationWhite Paper. Chemical dosing and blending - the role of precision actuators
White Paper Chemical dosing and blending - the role of precision actuators Chemical dosing and blending - the role of precision actuators White Paper 16 th August 2014 Chemical dosing and blending - the
More informationsanitary control valves & regulators
sanitary control valves & regulators Reputation Built on Quality, Dependability, Service. Get Consistent Quality By involving every employee in our ISO 9001:2000 Quality Assurance Program, you can count
More informationEFFECTS OF SHEAR AND CAVITATION ON PARTICLE AGGLOMERATION DURING HANDLING OF CMP SLURRIES CONTAINING SILICA, ALUMINA, AND CERIA PARTICLES
EFFECTS OF SHEAR AND CAVITATION ON PARTICLE AGGLOMERATION DURING HANDLING OF CMP SLURRIES CONTAINING SILICA, ALUMINA, AND CERIA PARTICLES Mark R. Litchy and Donald C. Grant CT Associates, Inc. Reto Schoeb
More informationPlunger pumps are used in a wide variety of
Kelly Eberle and Cajetan Ijeomah, Wood Group, Canada, outline a case study of vibration-induced cracks in a plunger pump piping system. Plunger pumps are used in a wide variety of applications, such as
More informationTechnological Advances for Improving Desulphurization of H 2 S from Sour Crude Oils and Process Waters
Technological Advances for Improving Desulphurization of H 2 S from Sour Crude Oils and Process Waters Sheldon McKee and Mike Shields AMGAS Williston Basin Petroleum Conference, Regina 2017 Sour Produced
More informationProserv Flushing Unit - Offshore
Flushing Services PRODUCTION Proserv Flushing Unit - Offshore Proserv offers a wide range of various flushing units with diesel-engine drive and electrical drive options for sale and hire. We have different
More informationLesson. Using Hydraulic Systems
Lesson Using Hydraulic Systems Interest Approach n Have you ever used a floor jack or driven an automobile equipped with power brakes or power steering? Student Learning Objectives n Define hydraulics
More informationAIR OPERATED GAS BOOSTERS
DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EQUIPMENT SC HYDRAULIC ENGINEERING CORPORATION AIR OPERATED GAS BOOSTERS A High Pressure History An innovator and pioneer in the field of hydraulic
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit
ABB MEASUREMENT & ANALYTICS DATA SHEET SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit 2 SCK SAMPLING SYSTEM DS/SCK-EN REV. A Measurement made easy Complete
More informationProduct overview Product overview
Product overview Product overview Control Control every move The experts for monitoring and control Pressure Temperature Level Flow Controls Barksdale The business of critical controls Market-focused.
More informationChemical Injection. Systems and Equipment for Oil and Natural Gas
Chemical Injection Systems and Equipment for Oil and Natural Gas Chemical Injection Product Scope Solar Powered Chemical Injection Systems Electric Chemical Injection Pumps Hazardous Location Pumps Pump
More information6" RETURN FROM PUMP RESERVOIR LABELED "ph" 6" RECIRCULATION SUCTION (TYP OF 2) 6" BUTTERFLY VALVE (TYP OF 2) 2" RECIRC PUMP TO FILTER RECIRCULATION PUMP 2" PUMP TO WASTE CHLORINE FEEDER ELECTRICAL PANEL
More informationSTATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES
STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: INT 118 (2011-1) version number (e.g.; INT 100 (2005-1)). Identifier is the postsecondary course
More informationBest Practices for Chemical Facility Design in Water Treatment. Sara N. Gibson, P.E.
Best Practices for Chemical Facility Design in Water Treatment Sara N. Gibson, P.E. Overview Introduction Design Considerations Storage Tanks Recirculation / Transfer Pumps Metering Pumps Piping and Valves
More informationAPI 675 Evaluation. Section 1 General. 1.5 Referenced Publications. 1.1 Scope. 1.6 Unit Conversion. 1.2 Alternative Designs
API 675 Evaluation Evaluation of Pumps for Conformity to the Requirements of API Standard 675: Positive Displacement Pumps Controlled Volume. Second Edition, October 1994 Section 1 General 1.1 Scope API
More informationSANITARY CONTROL VALVES & REGULATORS
SANITARY CONTROL VALVES & REGULATORS www.cashco com Innovative Solutions Get Consistent Quality By involving every employee in our ISO 9001:2008 Quality Assurance Program, you can count on the quality
More informationHusky Process Equipment Contractors Guide
Contractors Guide Air-Operated Double Diaphragm Pumps Product Selection Key Technical Specifications commercial, industrial, marine, mining & more Introduction Pump Selection Key Graco provide durable
More informationFLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.
FLUID FLOW - PUMPS 4 3 Control valve Suction Section Discharge Section Two main types of pumps: Positive Displacement pumps Centrifugal pumps ChE 453 - Design I FLUID FLOW - PUMP PERFORMANCE Mechanical
More informationCOMPRESSED AIR FILTERS HF SERIES
COMPRESSED AIR FILTERS HF SERIES COMPRESSED AIR TREATMENT REDUCES OPERATING COSTS Cut the Cost of Compressed Air. Hankison filters remove more contaminants with less pressure drop. Compare the operating
More informationSAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.
SAF Filters flow rates filtration degrees water for cleaning min. operating pressure up to 400 m³/h (1760 US gpm) 800- micron less than 1% of the total flow bar (30 psi) The automatic self-cleaning filter
More informationModule 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations
1 P age Module 9 : Sewage And Storm water Pumping Stations Lecture 11 : Sewage And Storm water Pumping Stations 2 P age 9.1 Introduction There are certain locations where it is possible to convey sewage
More informationForced Draft Decarbonators. Degasification
Forced Draft Decarbonators Degasification Forced Draft Decarbonator When do you need it? What is it? How does it work? In Ion Exchange Demineralizer Systems, Forced Draft Decarbonators are located between
More informationCompatibility of Scale Inhibitors and Biocides with Fracturing Fluids. Christy C. Wentworth, Ph.D.
Compatibility of Scale Inhibitors and Biocides with Fracturing Fluids Christy C. Wentworth, Ph.D. Agenda What Are Fracturing Fluids? Importance of Compatibility Scale Inhibitor and Biocides in Fracturing
More informationO I L S I G H T G L A S S E S
O I L S I G H T G L A S S E S Round The Clock Oil Inspection The Esco Oil Sight Glasses are designed for simple installation on most equipment. Constructed of durable acrylic, they withstand most petroleum
More informationWater Law. (Prior) Appropriation Doctrine: "diverting water and putting it to a beneficial use creates a water right"
Water Law Riparian Doctrine: "a landowner contiguous to a stream is entitled to have water of the stream flow by his/her land undiminished in quantity and unpolluted in quality" Based on English common
More informationPneumatic Cement Grout Pump
Pneumatic Cement Grout Pump Grout cement solution anywhere with zero complication. Manufactured by- Metro Industries, Bangalore(India). www.metroindustries.in www.groutingpumps.com Email: info@metroindustries.in
More informationConcentraFlo. Pipeline chemistry solutions and services
ConcentraFlo Pipeline chemistry solutions and services CHEMICALLY DRIVEN, COMPREHENSIVE SOLUTIONS FOR MAXIMUM THROUGHPUT Schlumberger specialists deliver integrated chemical, equipment, and analytical
More informationElectric Diaphragm Pumps Electric Operated Double Diaphragm Pump
Electric Diaphragm Pumps Electric Operated Double Diaphragm Pump Only electric diaphragm pump on the market that will stall under pressure Up to 80% more efficient than air operated diaphragm pumps Reduce
More informationProduction. 33
www.upstreampumping.com 33 A solar injection powered system installed at a wellhead site. Diaphragm Pumps Enhance Chemical Injection Systems During EOR Duncan McFarland, Ferguson Beauregard, & Sudip Sarker,
More informationDOSING-METERING PUMPS & DOSING SYSTEM
CREATIVE ENGINEERS 1 st Floor,Above Bhairavnath Post Office, Opp Pragati Society,Nr. Meera Cross Roads Maninagar,Ahmedabad - 380028 Tele Fax : + 91-079-25431453,8140179903 Website :- www.sspumpsindia.com,
More informationConcentraFlo. Pipeline chemistry solutions and services
ConcentraFlo Pipeline chemistry solutions and services CHEMICALLY DRIVEN, COMPREHENSIVE SOLUTIONS FOR MAXIMUM THROUGHPUT Schlumberger specialists deliver integrated chemical, equipment, and analytical
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationMETER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA
METER SELECTION FOR VARIOUS LOAD REQUIREMENTS Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX 78238-5166 USA INTRODUCTION This paper is intended to provide meter station
More information#287 FOOD GRADE FLUSHING AGENT
#287 FOOD GRADE FLUSHING AGENT Food Grade Flushing Agent is a non-toxic, non-drying, anti-wear flushing and cleaning lubricant that can be used to clean and flush all types of processing and packaging
More informationStandard Operating (Installation) Procedures (SOP) For Manual Refractory Shotcreting Applications
Standard Operating (Installation) Procedures (SOP) For Manual Refractory Shotcreting Applications Colloidal silica bonded refractory applications utilizing pneumatic shotcreting include vessel or component
More informationChemraz (FFKM) Overview
(FFKM) Overview 505 Energy Midstream Coupling Broad chemical compatibility for use with a wide range of harsh solutions Lower compression set increases ability to handle temp and pressure variations, shaft
More informationProMinent Evolution Series
ProMinent Evolution Series Hydraulic Diaphragm Metering Pumps Evolution 1 & 2 Evolution 3 & 4 Evolution Series The Evolution Series The ProMinent Evolution Series pumps are API 675, 3rd Edition compliant
More informationReverse Osmosis, Nano Filtration and Ultra Filtration
Seal-less Pump Technology Reverse Osmosis, Nano Filtration and Ultra Filtration Simplicity - Reliability Hydra-Cell Reverse Osmosis Pumps High reliability, Hydra-Cell pumps are used in a wide variety of
More informationCORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101
CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101 Kevin S. Fisher, P.E. and Kenneth E. McIntush, P.E. Trimeric Corporation Buda, Texas, U.S.A. Peter F. Ellis Honeywell Corrosion Solutions Houston,
More informationColfax Americas. Crude Oil Transport Solutions
Colfax Americas Crude Oil Transport Solutions Colfax at a Glance Colfax Corporation Colfax Corporation is a world leader in the development, engineering, manufacturing, distribution, service and support
More informationCollectors. Water Treatment & Chemical Processing
Water Treatment & Chemical Processing Collectors Screen Services Specialty screens and equipment for industrial, petrochemical, mining, and water treatment applications Page 2 Collector/Distributors fabricated
More informationINTRODUCTION. TXAM also leads the field in manufacturing & marketing of totally solar powered chemical injectors. Our solar pumps produce
COMPANY PROFILE INTRODUCTION Since 1986, TXAM has been an innovator in the manufacturing of safe chemical injectors. With an imaginative eye for the future, TXAM has designed, produced, field tested and
More informationPreface to the First Edition Preface to the Second Edition. Acknowledgment
Dedication Preface to the First Edition Preface to the Second Edition Forewords Acknowledgment iii xiii xv xvii xix Chapter 1 Introduction to Pipeline Systems 1 1.1 Introduction 1 1.2 Liquid Pipelines
More informationSHREE DUJA SPRAY EQUIPMENTS
ELECTRIC DRILL INJECTION PISTON PUMP - SD 04 SD-04 is one-component grouting injector which is used to inject epoxy or polyurethane filling materials to water-leaking cracks. SD-04 is a professional Injection
More informationRelays & Volume Boosters
Relays & Volume Boosters Type 20 Type 20 HR Type 20 EX HR Type 72 Type 72 HR HR Type 79 Type 79 HR www.marshbellofram.com 800.727.5646 37 Relays - Volume Boosters Comparison Chart Maximum Type 20 Type
More informationStandards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.
FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared
More informationUniversity Curriculum Development for Decentralized Wastewater Management
Page i University Curriculum Development for Decentralized Wastewater Management Module Text Paul Trotta, P.E., Ph.D. Justin Ramsey, P.E. Chad Cooper September 004 Page ii NDWRCDP Disclaimer This work
More informationCCSD & CCSE Series Oil/Water Separators
CCSD & CCSE Series Oil/Water Separators NEW Engineered to Save Oil/Water Separators Condensate generated by lubricated type air compressors is comprised of atmospheric borne water vapor and lubricant from
More informationFeatures: Highly durable Increases productivity Longer service life
We are most eminent manufacturers of a wide range of Drip Irrigation Fittings, which are made up of high grade raw materials. Our technicians leverage advanced machinery in fabricating these fittings.
More informationM1 LV insecticide EPA Reg. No
(NEW 3/22/12) 14-1 SUPPLEMENTAL LABELING M1 LV insecticide EPA Reg. No. 352-384-85588 FOR USE ON DRY AND SUCCULENT BEANS AND SUCCULENT PEAS VIA OVERHEAD SPRINKLER IRRIGATION IN THE STATES OF IDAHO, MONTANA,
More informationABEL EM. Electromechanical Membrane Pumps The economical alternative. From the reciprocating positive displacement pump specialist
ABEL EM From the reciprocating positive displacement pump specialist Electromechanical Membrane Pumps The economical alternative 1 Membrane Pumps Solids Handling Pumps High Pressure Pumps Marine Pumps
More informationFigure2-DalySinclairField(01)
Figure2-DalySinclairField(01) 10 anitoba Petroleum Branch Figure No. 2 5 5 5 : 7 7 ' 352326(' 6,1&/$,5 81,7 (%25 81,7 81,7 (:$57 81,7 ' (:$57 8 6,1&/$,5 81,7 7 ' '' 81,7 5 ' ' ' 5 5 : 7 FigureNo.3 Figure
More informationEngineering Excellence
Energy Saving Compressed Air Filters NGF SERIES 20 to 1500 scfm (34 to 2459 nm 3 /h) Engineering Excellence SPX is a place where innovation is valued, and the real needs of business are understood. We
More informationProduct Data Castrol Anvol WG46
Castrol Anvol WG46 Fire Resistant Hydraulic Fluids Description Castrol Anvol WG is a water glycol fire resistant hydraulic fluid that meets HFC 7th Luxembourg classification and Factory Mutual Category
More informationREVERSE OSMOSIS WATER TREATMENT
REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis
More informationModular Oil & Gas Equipment Onshore & Offshore
Modular Oil & Gas Equipment Onshore & Offshore Separators & Desalters AI Energy Solutions onshore and offshore oil process solutions offer innovative technologies packaged with global project management
More informationIndustrial Mechanic (Millwright) Level 3
Level 3 C1 Shaft Alignment II Duration: 10 hours 3 hours 7 hours This unit is designed to introduce knowledge of the procedures for shaft alignment using the reverse dial method. It is also designed to
More informationCOMBINATION AIR VALVE
MINING DIVISION COMBINATION AIR VALVE FOR HIGH FLOW D-6NS SERIES DESCRIPTION The D-6NS Series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The air release