1 Testing of Carbon Filters in Australian Nuclear Installations 31st International Nuclear Air Cleaning Conference, Charlotte NC 19-21July 9 Ju y Luis Rudenas Engineering & Technical Services Australian Nuclear Science and Technology Organisation
2 Carbon filter tests objectives Prevent reactor shutdown due to carbon filter failures Trained workshop personnel available at any time to refill carbon filters Easy to understand instructions to test filters by maintenance personnel New filter housing upgrades with modular designs of canisters and fire suppression Filtration system tested and reliable. Stack monitoring to check effectiveness
3 Adopted standards for assembling and testing filters at ANSTO ASME AG-1 Code on Nuclear Air and Gas Treatment ASTM Standard Test Method of Nuclear-Grade Activated Carbon ASME N Testing of Nuclear Air Treatment Systems ASME N Nuclear Power Plant Air-Cleaning Units and Components
4 Test of carbon filters Injection and sampling manifolds properly designed Air distribution test Aerosol uniformity test Mechanical integrity test, pulses of 1 Bromobutane Advantage of gas pulse is less gas used and the test can be repeated immediately Gas pulse test complemented by laboratory test t of installed canisters or by direct carbon sampling of filters
5 Response to carbon test results ASTM test failure requires carbon filters to be replaced Mechanical test failure requires filters to be reinstalled or replaced Availability of carbon with valid ASTM Certificate (5 years) Spare filters with valid certificate (5 years if never used)
6 Carbon filters used at ANSTO SIAM filters size 17.5 X 17.5 and 10 carbon depth, capacity 100 cfm. Area= 2.2 Sq. Ft. B23 Filters 24 X 24 and 10 carbon depth, capacity 200 cfm. Area= 4 Sq. Ft. Type IV (Flanders V-Bed) 24 X 24 and 2 carbon depth, capacity 700 cfm. Area= 16 Sq. Ft. Type IV (Flanders V-Bed) 24 X 12 and 2 carbon depth, capacity 500 cfm. Area= 8 Sq. Ft. Type IV (Flanders V-Bed) 24 X 24 and 1 carbon depth, capacity 1000 cfm Canisters used at ANSTO, 2 or 10 carbon depth and 2 internal diameter
7 Carbon filter ready for refilling Welded Screw
8 Facility to assemble filters Extract Ventilation Carbon Hopper Vibratoryy Table Scale
9 Pouring g carbon in the Filters
10 Removing g air after filling g filter
11 Crates designed for internal transport
12 Confined space arrangement Demountable rollers for filter installation
13 Filter handling in a confined space
14 ASTM test Direct sampling from filter Sample container
15 Two installed carbon canister modules 2 Canister 1 Pipe 2 Pipe Carbon Filters Air flow direction
16 Canister preparation 1 Pipe p Upper plenum Lower plenum Flow Check Points 2 Pipe to 2 housing
17 Different canister layout y Air flow 2 Pipe 1 Pipe Upper plenum Carbon Filters Lower plenum
18 Instruments for carbon testing NUCON Model HGPH Pulse Mode Halide Generator NUCON Model F-2000-HD ppm and ppb halide detector NUCON Model F-2000-BBD ppb halide detector NUCON Model F-1000-CR calibration rig to calibrate the halide detectors t Calibration gases 200 ppb and 36 ppm of 1 Bromobutane with corresponding clean air cylinders supplied by NUCON.
19 Testing set up Testing Pulse gas Portable fan assembly generator arrangement Portable HEPA filter/ fan assembly 50 mm ID hose From building exhaust Injection manifold Upstream sampling manifold Exhaust ppm ppb outputs Halide detector Halide detector In In Carbon filter under test Downstream sampling manifold Fan Portable HEPA filter/ fan assembly
20 Halide injection pulse test 1 ml of liquid 1 Bromobutane is equivalent to ml of gas at 20 o C 2238 L/s of air flow has 100 ppm of 1 Bromobutane gas when 1 ml of liquid is injected in one second Always measure upstream concentration to ensure proper gas injection and calculate penetration. Penetration = 100*Cd/Cu Maximum allowed penetration at ANSTO is 1% The downstream concentration may exceed the instrument t range when the carbon filter leaks
21 Copper testing manifold
22 Fitting 2 BSP of internal diameter to be pop riveted to a duct
23 Installing the testing manifold
24 Calibration gases ppm and ppb of 1 B Bromobutane b with i h clean l air i cylinders li d
25 Gas detectors ppm and ppb
26 Gas leak investigation in a side removable plate of a new filter ppb of 1 Bro omobut tane Injection time Time in minutes
27 Carbon filter housing requirements Canisters for surveillance testing Injection and sampling manifolds Inlet and outlet plenums Fire suppression Bubble tight dampers to isolate filters in case of fire or for maintenance purposes Carbon Monoxide sensors Thermocouples
28 Thermocouple activated water flood for fire suppression Air flow Keystone valve Sprinklers p 1 pipe Carbon filters Thermocouples 10 Long 10 canisters
29 Fire suppression for Cyclotron Canisters Thermocouples Air flow HEPA filters CO Sensors C b filt Carbon filters Keystone Valve
30 Fire suppression for Hot Cells Valve actuator Keystone Valves Canisters Air flow HEPA filters Thermocouples CO Sensor Carbon filters
31 Fire suppression panel CO and type K thermocouples CO Monitor Thermocouple displays
32 Stack monitoring Air flow rate monitoring using Flow Bar devices Off-line weekly monitoring using TC45 carbon cartridges for gases and Whatman filter papers for particulates Real time monitoring i for noble gases using NaI sensors and a Canberra Lynx multi- channel analyser
33 Equipment for stack monitoring Pressure alarm Stack sample line Stack air flow rate 100 ml Al container Lynx MCA NaI sensor Flowmeter Computer Flow signal Motor Pump Air flow 5 L/min Return line to stack Temperature controlled cabinet
34 Air flow rate device Flow bar Calibration nutserts
35 Display of stack flow Alarm pressure switch Flow display
36 Stack sampling TC45 & filter p paper p weekly sampler Pitot tube Sampling lines for real time
37 Performance of TC45 carbon cartridges Retention n Efficie ency CH H3I % TC12 TC30 TC45 Flow Rate (SCFM) Reproduced from HiQ data
38 Real time stack monitoring Operating System Platform Independent Real-time Monitor GBq MCA based program for looped endless measurement Date / Time 7:39 8:40 9:40 10:41 11:41 12:42 13:42 14:43 15:43 16:44 17:44 18:45 19:46 20:46 21:47 22:47 23:48 0:48 1:49 2:50 3:50 4:51 5:51 Time Xe 133 (5.3d) Kr 85m(4.5h) Kr 88(2.8h) Xe 135(9.2h) Kr 87(76m) Xe 135m(15m) MCA desktop desktop Internet Browser Based: Data Display Cumulative totals Data Base On-line data Spreadsheet format export notification equipment failure notification levels daily totals Network Server ANSTO Network Firewall Internet
39 Top view of NaI sensors for real time stack monitoring NaI sensor Shielding for sensors
40 Cabinet for stack monitoring g Computer Lynx Canberra MCA UPS Shielded NaI sensor
41 Real time stack monitoring display Gamma Spectrum kev
42 Conclusions Correctly design new filter housings with canisters, testing manifolds, bubble tight dampers and CO monitors Periodically test the carbon filters and be prepared for filter changes at any time Monitor filter performance with trends of weekly and real time releases through the stacks
43
24th DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE
--_-..- 24th DOE/NRC NUCLEAR AR CLEANNG AND TREATMENT CONFERENCE ACCURACY MPROVEMENT N LEAK DETECTON OF CHARCOAL ADSORBERS BY HALDE PULSE NTEGRATON METHOD. Bela J. Kovach, Eric M. Banks NUCON nternational,
More informationby W. Peter Freeman NUCON International, Inc. Columbus, Ohio
25fh DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE Leak Testing Filters Containing Activated Carbon Media with Different Moisture Contents Using a New Halide Detector by W. Peter Freeman NUCON
More informationRicardo-AEA. In-Situ Filter Testing & Stack Sampler Characterization. John Osbourn. Particle Measurement Centre.
Ricardo-AEA In-Situ Filter Testing & Stack Sampler Characterization John Osbourn Particle Measurement Centre www.ricardo-aea.com Outline In-Situ Filter Testing Stack Sampler Characterization Filtration
More information25fh DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE
25fh DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE AIR PURGE APPLIED TO SUBSTANTIALLY MITIGATE STACK RELEASE LEVELS RESULTING FROM BWR FUEL LEAK Peter G. Dorosko, PE Carolina Power & Light Brunswick
More informationDi ti agnos cs & O ti p i m t za ittion of of Pollution Control Systems y Dan Bemi MEGTEC Systems I nc Inc.
Diagnostics & Optimization i of Pollution Control Systems Dan Bemi MEGTEC Systems Inc. Oxidizer Functionality Concerns Process safety Directly effects fuel usage, both at the oxidizer and process Compliance
More informationASME COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT CONAGT
ASME COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT CONAGT The ASME Committee on Nuclear Air and Gas Treatment is responsible for the generation and maintenance of codes and standards that address Nuclear
More informationHeated FID OVF Portable THC/TVOC Analyzer
Heated FID OVF-3000 Portable THC/TVOC Analyzer The OVF-3000 is light weight and portable, competitively priced compact and fully heated FID (HFID) based total hydrocarbon analyzer for high accuracy, sensitivity
More information( ppm ) ( ppm ) ( ppm ) History :46:43
Industrial Portable Infrared Analyser Series GAS 3000P NDIR FLUE GAS Up to 5 gases : NO/NO(X) - SO2 - CO - CO2 - O2 Accuracy and linearity : conform to EN 15267-3 Reference methods (SRM) : CO (EN 15058
More informationThe Milton S. Hershey Medical Center Academic Support Building. AE Senior Thesis Kari Anne Donovan Mechanical Option
The Milton S. Hershey Medical Center Academic Support Building AE Senior Thesis Kari Anne Donovan Mechanical Option Presentation Outline Existing Conditions Distributed Chilled Water Feasibility Study
More informationFabric Filtration. Typical Dimensions Dirty gas flows into page 11/6/2015. EVE 402 Air Pollution Generation and Control. Chapter #5 Lectures (Part 6)
EVE 402 Air Pollution Generation and Control Chapter #5 Lectures (Part 6) Fabric Filtration One of the oldest and most widely-used methods for separating particles from a gas stream Particle-laden gas
More informationFuture Directions and Historical Development of NSF/ANSI 49 Biosafety Cabinetry: Design, Construction, Performance and Field Certification
Future Directions and Historical Development of NSF/ANSI 49 Biosafety Cabinetry: Design, Construction, Performance and Field Certification David S. Phillips, DM The world leader in serving science NSF/ANSI
More informationSorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while
Sorbents Evaluation Testing Facilities Several states have enacted Hg emission regulations that are more stringent than the CAMR milestones. For example, Massachusetts will require power plants to achieve
More informationRJ Engineering Systems, Inc. Company Profile
RJ Engineering Systems, Inc. Company Profile about us Specialists in system design, engineering, procurement & manufacturing RJ Engineering Systems, Inc (RJES) is a manufacturer of custom engineered equipment
More informationSwivel and Marine Systems. Swivel stack and fluid transfer systems for multiple applications
Swivel and Marine Systems Swivel stack and fluid transfer systems for multiple applications Swivel Stack Systems The swivel stack is the heart of the turret mooring and fluid transfer system (FTS). Reliability,
More informationLIVING QUARTERS module building principles General Features
LIVING QUARTERS module building principles General Features Emtunga builds both customer specified Living Quarters and LQ s according to our own preferred design. The design and fabrication is based on
More informationELEVATING VAM RTO INLET CONCENTRATION THROUGH CMM BLENDING FOR POWER GENERATION
DURR SYSTEMS, INC. CLEAN TECHNOLOGY SYSTEMS ELEVATING VAM RTO INLET CONCENTRATION THROUGH CMM BLENDING FOR POWER GENERATION Karl Walby Senior Key Account Manager 734-536-3423, karl.walby@durrusa.com ICAC
More informationDEVELOPMENT AND EVALUATION OF A CARBON FILTER FOR REMOVING DMSO VaPOR FROM THE EXHAUST OF THE W79 HE DISSOLUTION WORKSTATION *
DEVELOPMENT AND EVALUATION OF A CARBON FILTER FOR REMOVING DMSO VaPOR FROM THE EXHAUST OF THE W79 HE DISSOLUTION WORKSTATION * W. Bergman, K. Wilson, and G. 0. Nelson Lawrence Livermore National Laboratory
More informationIn-core measurements of fuel-clad interactions in the Halden reactor
In-core measurements of fuel-clad interactions in the Halden reactor Peter Bennett Halden Project IAEA Technical Meeting on Fuel Rod Instrumentation and In-Pile Measurement Techniques Halden, Norway 3
More informationModel of a Standard Operating Procedure (SOP) for manual gravimetric PM measurements with a Low Volume Sampler
Model of a Standard Operating Procedure (SOP) for manual gravimetric PM measurements with a Low Volume Sampler How to use this specimen SOP This model SOP aims at giving support to network operators in
More informationSection 6.6 BSL3 & ABSL3 Biocontainment
NIH Design Requirements Manual 8-22-12 Section 6.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Section 6.6
More informationUniversity of Delaware
SECTION 22 05 00_COMMON WORK FOR PLUMBING SYSTEM University Contact: Energy & Engineering Group (302) 831-1744 Part 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Start up 2. Factory Training 3. Quality
More informationEmerald Ventures Project No DRAFT FOR DISCUSSION PURPOSES-- HVAC ODOR CONTROL DESIGN CRITERIA
PART 1 - HVAC ODOR CONTROL 1.1 GENERAL --DRAFT FOR DISCUSSION PURPOSES-- HVAC ODOR CONTROL DESIGN CRITERIA A. This document describes the standards for odor control for the building and requirements that
More informationCase Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application
Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application Jeffrey D. Shellenberger, 1 James B. Gilmour, 1 Aku Rainio 2 ; 1 Foster Wheeler North America Corp., Pittsburgh,
More informationWood Products Energy Savings Guide
Wood Products Energy Savings Guide The Oregon wood products industry faces challenges of rising operating costs, rigorous product and safety standards, evolving environmental regulations and increasing
More informationGAS 3050P NDIR FLUE GAS
Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as
More informationValidation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges
Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges CONTENTS Part I. Overview 4 1. Introduction 4 2. Summary of Conclusions 4 Part II. Studies on Removal Efficiency 6
More informationMODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II
MODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II MICHAEL WALSH PRINCIPAL, R.G. VANDERWEIL ENGINEERS, LLP 274 Summer Street, Boston, MA 02210 (T) 617-423-7423 (F) 617-423-7401 mwalsh@vanderweil.com Module
More informationENSA ENWESA SERVICES INDEX
ENSA ENWESA SERVICES INDEX 1. ENGINEERING, DESIGN AND TECHNOLOGY SERVICES (Ensa / ENWESA) Ensa has extensive experience designing nuclear components and pressure vessels since 1973 according to international
More informationEMIOTEST 3114 Gravimetric dust meter set
Technical card EMIOTEST 3114 Gravimetric dust meter set 1. Purpose and scope of application Automatic dust meter EMIOTEST 3114, in its innovative technical solution, is a portable device designed to perform,
More informationAccutube Averaging Pitot Tubes
Accutube Averaging Pitot Tubes While other companies who are newer to the industry changed their tube shapes to Bullet, Diamond, or Flat-Face with assertions that each is better than the other; Meriam
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 16170 First edition 2016-07-01 Corrected version 2017-04 In situ test methods for high efficiency filter systems in industrial facilities Méthodes d essai in situ pour les systèmes
More informationWhat is molecular filtration?
What is molecular filtration? Molecular Filtration Fundamentals Molecules are 1,000-10,000 times smaller than the particles removed by HEPA filters There are many, many more molecules in the air than particles
More informationNot Just a Lot of Hot Air!
Not Just a Lot of Hot Air! In-line calibrating an Annubar Primary Flow Element in unconventional ductwork or plumbing. Short Course: 6A-4890 Photography & Video Recording Policy Photography and audio/video
More informationSAMPLING ISSUES AND THE IN-PLACE LEAK TEST. John R. Hunt NCS Corporation. Abstract
SAMPLING ISSUES AND THE IN-PLACE LEAK TEST John R. Hunt NCS Corporation Abstract Sampling manifolds have been accepted as a means of overcoming difficulties with non-homogeneity of the tracer-air stream
More informationA. The purpose of this section is to specify Division 23 responsibilities in the commissioning process.
SECTION 23 99 50 - (ADD#4) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationFORSYTH COUNTY OFFICE OF ENVIRONMENTAL ASSISTANCE AND PROTECTION
Page 1 of 9 FORSYTH COUNTY OFFICE OF ENVIRONMENTAL ASSISTANCE AND PROTECTION STANDARD OPERATING PROCEDURE (SOP) Zero Air Generators Signature Page Section 13 Page 2 of 9 By the signatures below, the Forsyth
More informationPoly Series. Polymer Preparation Unit. Your Choice, Our Commitment
Poly Series Polymer Preparation Unit Your Choice, Our Commitment 02 Solutions for Water & Industry SekO s Poly Series has been specifically designed to provide effective solutions to the needs of Water
More informationREGULATORY GUIDE 1.52 (Draft was issued as DG-1102)
U.S. NUCLEAR REGULATORY COMMISSION Revision 3 June 2001 REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 1.52 (Draft was issued as DG-1102) DESIGN, INSPECTION, AND TESTING CRITERIA
More informationCompact flue gas analyser: testo 300 M-I
220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial
More informationSUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM. By James T. Mailloux
SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM By James T. Mailloux Submitted to FABCO INDUSTRIES, INC. June 2005 ALDEN RESEARCH LABORATORY, INC. 30 Shrewsbury
More informationThe Power of Numbers. Zeton Altamira. Zeton Altamira
The Power of Numbers Zeton Altamira Zeton Altamira Zeton Altamira proudly introduces the A Multi-Channel Fixed Bed Reactor for High Throughput Screening of Heterogeneous Catalysts Developed as a tool for
More informationGilian BDX-II Air Sampling Pump Setup and Use
Gilian BDX-II Air Sampling Pump Gilian BDX-II Air Sampling Pump Setup and Use Gilian BDX-II Designed for ease-of-use in abatement applications Lead abatement Asbestos abatement Robust design Light weight
More informationPioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS
Pioneering ALD experience since 1974 The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS SUNALE P-SERIES ALD SYSTEMS PRODUCT CATALOGUE Description SUNALE P-series ALD system SUNALE P-series
More informationEGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians
Data 924-2 7/12/05 EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Features Complete sample-conditioning
More informationCOLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.
High /H comp NO NOx 2 LANM 4 www.lancom4.com NO2 2 H2S SO2 CXHY Portable Flue Gas Monitoring LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available.
More informationUniversity of Delaware
SECTION 23 05 00_COMMON WORK FOR HVAC SYSTEMS University Contact: Energy & Engineering Group (302) 831-1744 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Start up 2. Factory Training 3. Quality Control
More informationHydraulic systems Quality without cutting corners
Hydraulic systems Quality without cutting corners HYDRAULIC SYSTEMS Hydraulics: Large forces in a small space Movements in plant and machinery need the advantages of hydraulics: Large forces in a small
More informationMCBERNS ZC SERIES ODOUR FILTERS STANDARD SPECIFICATION
MCBERNS ZC SERIES ODOUR FILTERS STANDARD SPECIFICATION 1 INTRODUCTION The McBerns ZC series odour filters are designed for sewage pump stations, trunk sewerage systems, storage tanks, sewer air release
More informationCOLow COHigh COLow/H 2
High / comp NO NOx NO2 2 H2S Portable Flue Gas Monitoring SO2 LANM 4 CXHY www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In
More informationCOLow COHigh COLow/H 2
High /H comp NO NOx NO HS Portable Flue Gas Monitoring SO LANM 4 CXHY www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In excess
More informationEFFECTIVE STRATEGIES FOR RAGAGEP APPLICATION HOW TO MEET RAGAGEP COMPLIANCE FOR PSM & RMP SUMMARY
EFFECTIVE STRATEGIES FOR RAGAGEP APPLICATION HOW TO MEET RAGAGEP COMPLIANCE FOR PSM & RMP Stephanie Smith, PE Risk Management Professionals (949) 282-0123 (877) 532-0806 SUMMARY What is RAGAGEP? Sources
More informationRobust flue gas probes for industrial emissions measurements.
Robust flue gas probes for industrial emissions measurements. For reliable measurements using testo 340 and testo 350, even in the harshest of conditions. Robust flue gas probes for industrial emissions
More informationAIR FLOW HOOD TACHOMETERS
BC-HVAC PRODUCT OVERVIEW PRESSURE MANOMETERS SERIES AQTIA-WDPM 477AV 477B 475 490A Range 2 to 350 in w.c. (0.5 to 87 kpa) 1 in w.c. to 150 psi (.25 kpa to 10.34 bar) 20 in w.c. to 100 psi (4.982 to 689.5
More informationFiltered Containment Venting Systems
Swiss Federal Nuclear Safety Inspectorate ENSI Filtered Containment Venting Systems at Swiss NPPs and KKL in particular January 15, 2014, Ft. Lauderdale J. Hammer, ENSI, and A. Ritter, KKL Agenda Swiss
More informationDetermination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document
Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers A Guidance Document Report EC 1/RM/5 July 007 Readers Comments Inquiries pertaining to the use of this document should be
More informationCOLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx
High /H comp NO NOx Portable Flue Gas Monitoring LANM 4 NO H S SO C X H Y www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In
More informationTechnical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions
Technical Guidance Note (Monitoring) M5 Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Environment Agency XXXX 2018 Version X Draft for consultation Foreword
More informationSOP SMPS BaltimorePM supersite Version 2 November 20, 2000 Page 1 of 1. SEAS Chemistry
Page 1 of 1 RP DRAFT - MEASUREMENT AND ANALYSIS OF THE CHEMICAL COMPOSTION OF THE AMBIENT AEROSOL USING SEAS Identification code: RP RP Working RP pages APPROVALS Issue Date: /. Local PI: / / Revision
More informationOhio Energy. Workshop G. Energy Efficiency Through Better Control: Maximizing the Energy Efficiency by Minimizing Waste
Ohio Energy Workshop G Energy Efficiency Through Better Control: Maximizing the Energy Efficiency by Minimizing Waste Tuesday, February 16, 2016 10:45 a.m. to Noon Biographical Information J. Kelly Kissock,
More informationSupplier & manufacturer of abrasive blasting equipment, abrasives, servicing & training. Blast Rooms
Supplier & manufacturer of abrasive blasting equipment, abrasives, servicing & training Blast Rooms The Hodge Clemco Way Leading the way in surface preparation since 1959, Hodge Clemco has consistently
More informationWINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR
Supplier Checklist WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR The following checklist provides guidance on which information to collect from within the winery and from the equipment
More informationLargo & Allegro. Air Compressors. Largo & Allegro
Largo & Allegro Air Compressors Largo 110-160 & Allegro 110-180 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer
More informationINTEGRATED VPHP DECONTAMINATION SYSTEMS THE EMERGING UTILITY
INTEGRATED VPHP DECONTAMINATION SYSTEMS THE EMERGING UTILITY John Klostermyer, Ph.D. ISPE Product Show Track 3 Session 3 September 26, 2018 AGENDA 1. BACKGROUND INFORMATION 2. BENEFITS 3. PROCESS 4. BEST
More informationRETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery
RETROFIT SOLUTIONS For Gas Turbines And Rotating Machinery B E T T E R A I R I S O U R B U S I N E S S PERFORMANCE ENHANCING RETROFIT SOLUTIONS FOR GAS TURBINES AND ROTATING MACHINERY OUR AFTERMARKET QUALIFICATIONS
More informationtesto 320. Combustion analysis in HD High Def & Heavy Duty For Residential & Commercial Applications 1
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 320. Combustion analysis in HD High Def & Heavy Duty For Residential & Commercial
More information- 1 - InfraStruXure InRow SC Assembly and Start-Up. Installation Service
Installation Service - 1 - InfraStruXure InRow SC Assembly and Start-Up Statement of Work 1.0 Executive Summary InfraStruXure InRow SC Assembly & Start-Up Service Table of Contents 1.0 Executive Summary
More informationTest Report TR1R0
1 CLIENT DETAILS Organisation: Company Contact: Cogent Energy Pty Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Suite 2, Level 9, 1 Chandos Street, St Leonards
More informationTECHNICAL SPECIFICATION SDI C. Automated Ultrasonic Heavy Duty Cylinder Inspection System
TECHNICAL SPECIFICATION SDI-5280-624C Automated Ultrasonic Heavy Duty Cylinder Inspection System Structural 650 Via Alondra, Camarillo, CA 93012 Tel:(805) 987 7755 Fax(805) 987 7791 Page 1 of 10 Automatic
More informationOutdoor air treatment units
Outdoor air treatment units A +++ A ++ A + A B C D ErP Fresh Air Unit The FAU series of outdoor air treatment units, with Lossnay enthalpic energy recovery module, direct expansion coil and integrated
More informationCompressed Air Filters Sample Filters
Compressed Air Compressed Air Sample Balston Sample Protect Sensitive Analyzers Balston Gas and Liquid Sample Analyzer protect analyzers from sample impurities by removing solids and liquids from gases
More informationFabric Filter Systems. Providing compliance level control for difficult applications. United McGill products. a McGill AirClean product
United McGill products a McGill AirClean product Fabric Filter Systems Providing compliance level control for difficult applications An enterprise of United McGill Corporation Family owned and operated
More informationTOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT. By James T. Mailloux Dean K. White
TOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT By James T. Mailloux Dean K. White Submitted to ADVANCED DRAINAGE SYSTEMS 250-04/H1098F September 2004 TOTAL SUSPENDED
More informationtesto 335 New measurement engineering for monitoring emissions
8 testo 335 New engineering for monitoring emissions How many ppm NO are there really? Knut Hoyer, Head of Product Development Gas How sure can you really be that your analyzer measures exactly what it
More informationCurrent as of 11/10/08 1 of 5
BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that
More informationVentilation systems and components of nuclear power plants
Ohje Guide FI9700105 Ventilation systems and components of nuclear power plants Sateilyturvakeskus Stralsakerhetscentralen Finnish Centre for Radiation and Nuclear Safety RADIATION AND NUCLEAR SAFETY AUTHORITY
More informationTest Report TR1R1
1 CLIENT DETAILS Organisation: Company Contact: Origin Energy Services Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Level 7, 321 Exhibition Street, Melbourne
More informationCHAPTER 6 : GAS SAMPLING SYSTEMS
CHAPTER 6 : GAS SAMPLING SYSTEMS 1 Scope : 1.1 This Chapter describes two types of gas sampling systems in paragraphs 2.1 and 2.2 meeting the requirements specified in para 4.2 of Chapter 3 of this Part.
More informationRecommended Methods to Evaluate Performance of Variable Air Volume Fume Hood Systems
AIHEC VENT 2006 Recommended Methods to Evaluate Performance of Variable Air Volume Fume Hood Systems Thomas C. Smith Exposure Control Technologies, Inc. Safety is the Primary Objective Lab Occupancy 26%
More information2015 International Mechanical Code Errata (Portions of text and tables not shown are unaffected by the errata)
PIPING MATERIAL 1 ST PRINTING (September 1, 2015) CHAPTER 3 GENERAL REGULATIONS TABLE 305.4 PIPING SUPPORT SPACING a MAXIMUM HORIZONTAL SPACING (feet) MAXIMUM VERTICAL SPACING (feet) ABS pipe 4 10 c Aluminum
More informationIndoor Air Quality and Mechanical Ventilation (Page 1 of 5)
Indoor Air Quality and Mechanical Ventilation (Page 1 of 5) Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard62.2.
More informationDETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS
MS 1596: 2003 DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS Presented BY: UiTM A&A Laboratory Malaysia s 1 st University Affiliated Environmental
More informationRollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V
Rollair Air Compressors ROLLAIR 150E-150-180-220 AND ROLLAIR 150V-180V-240V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial
More informationtesto 445 Additional information at Service instrument for ventilation/air conditioning systems
Service instrument for ventilation/air conditioning systems The testo 445 VAC instrument measures temperature, relative humidity, dew point, absolute humidity, degree of humidity, enthalpy, all types of
More informationContinuously Regenerated Trap (CR-TC 500, Capillary)
Thermo Scientific Continuously Regenerated Trap (CR-TC 500, Capillary) Column Product Manual P/N: November 2012 Part of Thermo Fisher Scientific Product Manual for Continuously Regenerated Trap Column
More informationMECHANICAL SPEC 1/6 MECHANICAL SPECIFICATIONS
MECHANICAL SPEC 1/6 MECHANICAL SPECIFICATIONS 1. Reference Standards 1.1. National Building Code, and Provincial Amendments (NBC) 1.2. National Plumbing Code, and Provincial Amendments (NPC) 1.3. Applicable
More informationDSS DOSING STANDARD SKIDS. Data Book. Pre-designed, assembled and tested chemical dosing skid.
DSS DOSING STANDARD SKIDS Data Book Pre-designed, assembled and tested chemical dosing skid. CONTENTS 1. GENERAL DATA 1.1 General description 3 2. IDENTIFICATION 2.1 Type key 4 2.2 Quick selection guide
More informationIndoor Air Quality Solutions
Indoor Air Quality Solutions Ultimate Solutions for Indoor Air Quality Investigation Demand for quality indoor air continues to increase as we are spending more time indoors than ever before. Indoor air
More informationVAC measuring instrument
VAC measuring instrument testo 445 The service instrument for ventilation and air conditioing systems Point and timed mean value calculation C Direct display of the volume flow Automatic allocation of
More informationLNG BUNKER CHECKLIST PORT OF ENERGY IN GOTHENBURG SHIP TO SHIP
PORT OF ENERGY IN GOTHENBURG SHIP TO SHIP Original: Ship Copy 1: Bunker Copy 2: 1/7 Bunker name Berth Port of arrival Time of arrival Terminal The presence of the letters, R or P in the column entitled
More informationVAC measuring instrument
VAC measuring instrument testo 445 The service instrument for ventilation and air conditioning systems Point and timed mean value calculation C Direct display of the volume flow Automatic allocation of
More informationCOMPRESSED AIR SYSTEM DESIGNS BEGIN WITH THE DEMANDS
COMPRESSED AIR SYSTEM DESIGNS BEGIN WITH THE DEMANDS BY: BILL SCALES, P.E. SCALES INDUSTRIAL TECHNOLOGIES, INC. The purpose of an assessment of an existing compressed air system, or design of a new one,
More informationLABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationTABLE OF CONTENT
Page : 1 of 10 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
More informationNew Measurement Engineering For Monitoring Emissions In Industry
testo 335 New Measurement Engineering For Monitoring Emissions In Industry Increased efficiency and convenience NEW! C O 2 CO/H 2 CO low /H 2 NO NO low NO 2 SO 2 hpa m 3 /s kg/h qa λ The new analyser generation
More informationAerosol Short Course: Physics, Measurement, and Sampling
Aerosol Short Course: Physics, Measurement, and Sampling Boeing Ed Wells Course Tom Peters The University of Iowa Department of Occupational and Environmental Health Iowa City, IA III. Sampling Overview
More informationMSC Guidelines for Review of Ventilation System Plans
K. B. FERRIE, CDR, Chief, Hull Division Purpose: This Plan Review Guideline (PRG) explains the requirements for seeking plan approval of ventilation systems from the Marine Safety Center (MSC) for most
More informationORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 2/12/2013 BUILDING SURVEY DATE
0052 500 SOUTH GOODWIN AVENUE URBANA, ILLINOIS 61801 SYSTEM CONDITION INDEX.721 PRIMARY BUILDING USE BUILDING SURVEY TEAM BUILDING SYSTEM REPLACEMENT COST $ 34,169,800 PARKING STRUCTURE BUILDING GROSS
More informationRosemount 405 Compact Orifice Primary Element
Rosemount 405 Compact Orifice Primary Element SPECIFICATIONS Performance Discharge Coefficient Uncertainty TABLE 20. 405 Compact Orifice Primary Element Type 405C (Conditioning Compact) 405P (1)(2) (Standard
More informationClean Air Cut Cell TM
Clean Air Cut Cell TM Clean indoor air begins at the Production Line Clean Air America, Inc. has successfully applied A New Generation of Plasma and Laser Fume Control Systems to hundreds of heavy-manufacturing
More informationSECTION AIR TERMINAL UNITS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More information