21/05/2014 FTIR AS HCN MEASUREMENT METHOD IN A FLUID CATALYTIC CRACKING UNIT. G. Lenaers, E. Damen, R. Brabers, W. Aerts, B. Baeyens, W.

Size: px
Start display at page:

Download "21/05/2014 FTIR AS HCN MEASUREMENT METHOD IN A FLUID CATALYTIC CRACKING UNIT. G. Lenaers, E. Damen, R. Brabers, W. Aerts, B. Baeyens, W."

Transcription

1 21/05/2014 FTIR AS HCN MEASUREMENT METHOD IN A FLUID CATALYTIC CRACKING UNIT G. Lenaers, E. Damen, R. Brabers, W. Aerts, B. Baeyens, W. Wouters

2 Outline» Goal» Fluid Catalytic Cracking Unit FCCU and HCN» FTIR suitability testing» FCCU measurements» Experiments on the reconstructed gas matrix» Results HCN-measurements on the FCCU» FTIR as continuous HCN measurement method 21/05/2014 2

3 Goal» In the Flemish Region an official request was made to change the regulation for HCN emissions in the sector of oil refineries for installations for the catalytic cracking over the fluid bed method at regeneration of the catalyst.» Next to a proposed new monthly average limit value of 50 mg/nm 3 -up from 5 mg/nm 3 - the addition of FTIR as a continuous measurement method for HCN is requested.» At present the HCN emissions need to be determined over the draft EPA OTM- 29 wet chemistry method. This method specifically takes account for problems in the analytical determination of HCN emissions in catalytic cracking units mainly by using a 6N NaOH absorption solution to keep the ph above 12 and thus preventing the loss of gaseous HCN from this solution.» The goal of this study is to investigate if FTIR has the potential for an alternative HCN measurement method at a FCCU. The EPA OTM-29 wet chemistry method is used as a reference method.» The study is commissioned by the Flemish Government. 21/05/2014 3

4 Fluid Catalytic Cracking Unit FCCU and HCN P P T STOOKGAS HCN LCDO FRACTIONATOR TOREN ABSORBER HCDO ALKY BLENDING SCHOORSTEEN ESP REGENERATOR VAT REACTOR VAT GOFINATE FORNUIS LUCHT 21/05/2014 4

5 Fluid Catalytic Cracking Unit FCCU and HCN» In the refinery process of crude oil the residual fraction containing heavy components is fed to a FCCU for conversion to petrol, diesel, LPG etc. With the help of heat and a catalyst the long hydrocarbon chains are cracked.» Cokes are formed that deposit on the catalyst and deactivate it. To restore the activity of the catalyst the cokes are burned off in the regenerator under addition of air to the fluidised catalyst.» Nitrogen compounds on the cokes react in the regenerator with HCN formation 21/05/2014 5

6 FTIR Gasmet DX /05/2014 6

7 FTIR suitability testing» Recording of new water reference spectra with reproducibility check from 1 to 28 vol%, regression R 2 =1, repetition yields same regression line» Establishing a calibration line between 0.1 and 3 times the ELV for HCN in dry nitrogen gas including determination of linearity and reproducibility check from 0.5 to 150 mg/nm 3, regression R 2 =1, repetition = same regression line» Establishing a calibration line between 0.1 and 3 times the ELV for HCN in wet nitrogen gas including determination of linearity from 0.5 to 150 mg/nm 3, around 10% H 2 O, regression R 2 =1» Establishing a calibration line between 0.1 and 3 times the ELV for HCN in a fixed flue gas matrix including determination of linearity» Measurement of a flue gas matrix of varying composition together with HCN 21/05/2014 7

8 FTIR suitability testing Establishing a HCN calibration line in a fixed flue gas matrix The concentrations are at the expected level in the FCCU flue gas 21/05/2014 8

9 FTIR suitability testing Establishing a HCN calibration line in a fixed flue gas matrix the HCN regression has a R 2 of 1 and the calibration line shows a coefficient near 1 and an intercept of only -0.2 ppm 21/05/2014 9

10 FTIR suitability testing Measurement of a flue gas matrix of varying composition together with HCN» Can the individual matrix components be determined?» over a wide concentration range» in the presence of the other matrix components» in the presence of HCN» A partially optimised FTIR-libraryfile was used in analysing the spectrum. This file consists of:» the components present in the matrix,» a list of interfering components per component,» the selected areas in the infrared spectrum for analysis per component adapted to the interfering compounds,» and if necessary advanced corrections for remaining cross interferences. 21/05/

11 FTIR suitability testing Measurement of a flue gas matrix of varying composition together with HCN 21/05/

12 FTIR suitability testing Measurement of a flue gas matrix of varying composition together with HCN 21/05/

13 FTIR suitability testing Measurement of a flue gas matrix of varying composition together with HCN» HCN is measured rather well: about 1.5 ppm too low on a level of 30 ppm i.e. 5%.» The other components are measured within 10 % with a few exceptions.» Thus the composition of the FCCU gas matrix can be measured in a reliable way. This is required to be able to accurately generate this matrix when developing a dedicated libraryfile for the measurement of HCN at the FCCU. 21/05/

14 FCCU measurements 1. To enable the actual measurements on the flue gas of the FCCU-regenerator a measurement set-up was built that allowed next to the FTIR measurements simultaneous sampling according to EPA OTM-29 that serves as the reference method. 2. Then the measurements on the FCCU were executed. 3. Next the measured gas matrix was reconstructed over the gas generation facility of the reference lab and a dedicated FTIR-libraryfile realised. 4. Finally the measurements on the FCCU were analysed with this dedicated libraryfile and the results compared to those of the EPA OTM-29 reference measurements. 21/05/

15 FCCU measurements Measurement system 21/05/

16 FCCU measurements Reference HCN determination: EPA OTM-29 method» Impinger method with 6N NaOH absorption liquid» equipped with a purpose built third impinger that allowed for the insertion of a ph electrode to make sure that the ph in this impinger did not fall below 12 21/05/

17 FCCU measurements 21/05/

18 Experiments on the reconstructed gas matrix» The FTIR measurements on the FCCU revealed the components and their concentration levels in the gas matrix. This allows reconstructing the gas matrix with known concentrations that are used as reference values to compare to FTIR measurements executed on this matrix. The FTIR library file is then fine tuned to a dedicated one that yields the best possible match with the reference values.» By varying -over different steps in the gas generation- the concentrations of some components versus each other while other remain constant, interferences become clearer and can be eliminated more efficiently.» Next to HCN the generated matrix consists of CO 2, H 2 O, SO 2, NO 2, NO en CO. 21/05/

19 Experiments on the reconstructed gas matrix Check on the EPA OTM-29 method» Two FCCU matrices are generated both with 15% CO 2 and 15% H 2 O and with resp. 20 and 42 ppm HCN. 20 ppm HCN is the level found in the FCCU whereas 42 ppm equals the requested ELV of 50 mg/nm 3. 15% of both CO 2 and H 2 O are the maximum levels in the flue gas. They represent the worst conditions as to lowering the ph level of the absorption liquid by acidifying (CO 2 ) and diluting (H 2 O) it. SO 2 and NO 2 will further acidify the liquid.» For each matrix three parallel wet chemical samplings are executed. The average result per matrix is compared to the reference value. As the differences are only 2% it is concluded that the EPA OTM-29 method was a good reference method for use during the measurements on the FCCU. wet chem. HCN measured HCN average HCN reference Differ. vs ref Differ. vs ref test mg/nm 3 mg/nm 3 mg/nm 3 mg/nm 3 % /05/

20 Experiments on the reconstructed gas matrix Main experiment» The generated water concentration varies between the steps from 10 to 15% and the CO 2 concentration from 12 to 15%.» HCN is generated between 5 and 150 mg/nm 3 i.e. from the current ELV -and also 0.1 times the requested ELV- till 3 times the requested ELV. The aim is to investigate if the FTIR analyser can be used to compare its measured values to an ELV.» The measured values are calculated starting from two libraryfiles: the dedicated FTIRVito4.lib and the FTIRbaselib. This last one is a base library that was included at delivery of the FTIR. It is not optimised for the gas matrix and serves here to show the difference to the dedicated library. 21/05/

21 Experiments on the reconstructed gas matrix 21/05/

22 Experiments on the reconstructed gas matrix 21/05/

23 Experiments on the reconstructed gas matrix 21/05/

24 » HCN: Experiments on the reconstructed gas matrix» The difference between the reference values and those from the FTIRVito4.lib are small: maximum 2.1 ppm at 125 ppm; 0.2 ppm at 42 ppm; 0.6 ppm at 20 ppm en 0.4 ppm at 4 ppm.» An increase in the differences below 4 ppm is not to be expected as the FTIR was shown to behave very linear for HCN in flue gas.» All interferences have been corrected for to a large extent.» The FTIRbaselib delivers values too low and suffers from interferences.» Other components:» The comparison yields differences of a few percent at maximum.» The FTIRbaselib is only at an acceptable level for H 2 O.» On the basis of these experiments it is concluded that FTIR has the potential to guard an ELV for HCN. 21/05/

25 Results HCN-measurements on the FCCU The measurements on the FCCU were analysed with the dedicated libraryfile and the results compared to those of the EPA OTM-29 reference measurements Date Time FTIR FTIR Wet chemical Difference FTIR VITO4 LIB 2012 base LIB VITO4 LIB VITO vs wet chemical mg/nm³ mg/nm³ mg/nm³ % 22/nov 11:10-12:10 13,8 17,5 20,0-12,4 12:19-13:19 15,1 18,8 18,8 0,0 26/nov 10:15-11:15 16,0 19,8 24,0-17,5 11:25-12:25 17,2 21,0 23,5-10,9 3/dec 12:35-13:35 19,4 23,3 23,1 0,8 13:45-14:45 21,9 25,6 24,0 7,0 average -5,5 STDEV 9,4 The dedicated libraryfile delivers comparable results to the reference method: the average difference is -5.5% +/- 9.4% 21/05/

26 FTIR as continuous HCN measurement method» FTIR has potential as a continuous measurement method for HCN at FCCU s. The term continuous measurement method covers two possible options as a FTIRanalyser intrinsically measures continuously:» A first option is the use in short term periodical measurements during which the FTIR analyser measures continuously. Within CEN TC 264 the new Working Group WG36 is working on an EN standard for periodical FTIR measurements. This standard will built on the UK Technical Guidance Note TGN M22 and the US EPA method 320 (or comparable ASTM D 6348 test method).» A second option is the use as AMS (Automated Measurement Systems) or CEMS (Continuous Emissions Monitoring Systems). In this case the FTIRanalyser measures continuously without interruption.» It should be stressed that quality assurance is necessary according to national, European or international standards.» The use of FTIR should be left to those with a sufficient knowledge of the base principles of FTIR as well as of the software for spectral analysis. 21/05/

27 Questions 21/05/

Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations

Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations www.trcsolutions.com November 10, 2016 oduction 2011 ICR for Refinery Sector requested HCN emissionss from FCCU Requested Method was

More information

Report. Report no. 1/19. An overview of HCN emissions from FCCU s and their potential impacts on human health

Report. Report no. 1/19. An overview of HCN emissions from FCCU s and their potential impacts on human health " Report Report no. 1/19 An overview of HCN emissions from FCCU s and their potential impacts on human health An overview of HCN emissions from FCCU s and their potential impacts on human health Prepared

More information

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER 1 INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER Brief introduction, thoughts and experiences MOTIVATION FOR EMISSION MEASUREMENTS 2 Condition of environment Air quality Emission studies Dispersion models

More information

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW NPL REPORT AS 26 Validation of an Alternative Method for the measurement of SO 2 emissions using instrumental methods Rod Robinson, Marc Coleman, Matthew Williams, Robert Elliott, Martin Clack, Andrew

More information

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND Hydrogen Purity Analysis by FTIR PROBLEM Historically, hydrogen has been employed in a variety of industrial chemical processes. Typically, the purity requirements for this hydrogen have tolerated contaminant

More information

Reprinted from November 2015 ENGINEERING HYDROCARBON

Reprinted from November 2015 ENGINEERING HYDROCARBON Shaun Pan, Alexis Shackleford, Robert McGuire Jr., Gary M. Smith and Bilge Yilmaz, BASF Corporation, USA, explain how operators can increase FCC unit profitability using catalysts from boron based technology.

More information

Technical TFTEI meeting of 24 June Agenda

Technical TFTEI meeting of 24 June Agenda Guidance document for estimation and measurement of VOC emissions from activities covered by annex VI of the Gothenburg Protocol Technical TFTEI meeting of 24 June 2015 Nadine ALLEMAND (Technical secretariat)

More information

The challenges of selecting the optimal catalyst for your FCC unit. MEDW 2013 Carel Pouwels, Ken Bruno

The challenges of selecting the optimal catalyst for your FCC unit. MEDW 2013 Carel Pouwels, Ken Bruno The challenges of selecting the optimal catalyst for your FCC unit MEDW 2013 Carel Pouwels, Ken Bruno January 3, 2009 Outline 1.Is catalyst testing telling the truth? 2.The disconnect between catalyst

More information

EPA vs. EN standards

EPA vs. EN standards EPA vs. EN standards 1 Tasks Goal: Determination of differences and similarities of EN and EPA to get a guideline what to change to be consistent within the EN CEMS framework Text comparison Approx. 1

More information

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC UOP 63-13: Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC Fast Analysis in

More information

Reforming is an upgrading process in which low octane gasoline is converted to high octane gasoline.

Reforming is an upgrading process in which low octane gasoline is converted to high octane gasoline. REFORMING Reforming is an upgrading process in which low octane gasoline is converted to high octane gasoline. Catalytic reforming primarily increases the octane of motor gasoline rather than increasing

More information

1. ESPs for Electric Utilities

1. ESPs for Electric Utilities Depending on the test method required for permitting, the solid particulate (rocks) can make up all or only a part of the measured particulate. Often-times people refer to the front half catch as the filterable

More information

Improving H 2 O Measurement in Catalytic Reformer Hydrogen Recycle Streams

Improving H 2 O Measurement in Catalytic Reformer Hydrogen Recycle Streams Improving H 2 O Measurement in Catalytic Reformer Hydrogen Recycle Streams On-line, real-time moisture measurements in catalytic reformer hydrogen recycle gas streams help refineries assess catalyst condition

More information

Measurement of H 2 O in Catalytic Reformer Hydrogen Recycle Streams Using Tunable Diode Laser Absorption Spectroscopy (TDLAS)

Measurement of H 2 O in Catalytic Reformer Hydrogen Recycle Streams Using Tunable Diode Laser Absorption Spectroscopy (TDLAS) Measurement of H 2 O in Catalytic Reformer Hydrogen Recycle Streams Using Tunable Diode Laser Absorption Spectroscopy (TDLAS) by W. Gary Engelhart, Product Line Marketing Manager, SpectraSensors, Inc.

More information

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry Introduction New environmental regulations have recently prompted many oil refineries and

More information

Technical Information Paper. (R)FCC Slurry Oil Filtration

Technical Information Paper. (R)FCC Slurry Oil Filtration Technical Information Paper Revision 0, June 2009 INDEX 1. Introduction 1.1 Removing catalyst particles 1.2 Creating value 2. Automatic Gas Assisted Backwash Filtration 2.1 Filter Principles 2.2 Filter

More information

An Overview of Mercury Monitoring Options

An Overview of Mercury Monitoring Options An Overview of Mercury Monitoring Options David Graham, Uniper Technologies Ltd. CRF 27 th Annual Meeting, Imperial College, London, 20 April 2016 Introduction What do we need to measure? Total mercury

More information

Predictive emission monitoring systems The power of software analyzers

Predictive emission monitoring systems The power of software analyzers ABB MEASUREMENT & ANALYTICS ARTICLE Predictive emission monitoring systems The power of software analyzers Gregorio Ciarlo, Federico Callero and Maurizio Simonelli, ABB SpA, Italy, discuss the application

More information

Fischer Tropsch Catalyst Test on Coal-Derived Synthesis Gas

Fischer Tropsch Catalyst Test on Coal-Derived Synthesis Gas Fischer Tropsch Catalyst Test on Coal-Derived Synthesis Gas Introduction Coal represents a major energy source that can be transformed into transportation fuels and chemical feedstocks. The United States

More information

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Technical Guidance Note (Monitoring) M5 Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Environment Agency XXXX 2018 Version X Draft for consultation Foreword

More information

Simultaneous process and emission monitoring through two automatically

Simultaneous process and emission monitoring through two automatically Simultaneous process and emission monitoring through two automatically Simultaneous process and emission monitoring through two automatically Speaker: Luigi Fiorani Authors: Luigi Fiorani Davide Tittarelli

More information

The development of instrumentation for application to carbon capture and storage measurements

The development of instrumentation for application to carbon capture and storage measurements The development of instrumentation for application to carbon capture and storage measurements Nicholas A Martin National Physical Laboratory (NPL), Analytical Science Division, Environmental Measurements

More information

Measurement of composite surface contamination using the Agilent 4100 ExoScan FTIR with diffuse reflectance sampling interface

Measurement of composite surface contamination using the Agilent 4100 ExoScan FTIR with diffuse reflectance sampling interface Measurement of composite surface contamination using the Agilent 4100 ExoScan FTIR with diffuse reflectance sampling interface Application note Author Materials testing John Seelenbinder Agilent Technologies

More information

FCC Flue Gas Treatment by implementing BELCO Wet Scrubbing Technology

FCC Flue Gas Treatment by implementing BELCO Wet Scrubbing Technology FCC Flue Gas Treatment by implementing BELCO Wet Scrubbing Technology Florin Enache, Process Engineering Department, Petrotel-Lukoil John Ramesh Bothsa, Senior Consultant Business Development & Technical,

More information

Development of Colorimetric Analysis for Determination the Concentration of Oil in Produce Water

Development of Colorimetric Analysis for Determination the Concentration of Oil in Produce Water Development of Colorimetric Analysis for Determination the Concentration of Oil in Produce Water M. S. Suliman, Sahl Yasin, Mohamed S. Ali To cite this version: M. S. Suliman, Sahl Yasin, Mohamed S. Ali.

More information

FCC Additives for Increased Residue Processing and Slurry Upgrading

FCC Additives for Increased Residue Processing and Slurry Upgrading FCC Additives for Increased Residue Processing and Slurry Upgrading Ilya Kryukov Technical Sales Manager Process Technologies Intercat Johnson Matthey Overview Evaluate upgrade potential Feed effects Histogram

More information

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators Technical Guidance Note (Monitoring) M5 Monitoring of stack gas emissions from medium combustion plants and specified generators Environment Agency September 2018 Draft Version Foreword This technical

More information

How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products. Presented by: Dr. Yanqia Wang

How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products. Presented by: Dr. Yanqia Wang How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products Presented by: Dr. Yanqia Wang Petroleum Products Petroleum products are materials derived from crude oil (petroleum) as

More information

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) Application note AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) The new LGR-ICOS TM laser process analyzer from ABB provides

More information

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS Paper Presented by: Shane Jordan-Hill Author: Shane Jordan-Hill, Business Manager Environmental Analysis, Merck Millipore 6 th Annual

More information

FINE PARTICULATE COLLECTION USING DRY ELECTROSTATIC PRECIPITATORS

FINE PARTICULATE COLLECTION USING DRY ELECTROSTATIC PRECIPITATORS FINE PARTICULATE COLLECTION USING DRY ELECTROSTATIC PRECIPITATORS Robert A. Mastropietro Lodge-Cottrell Inc. 2319 Timerloch Place, Suite E The Woodlands, TX 77380 INTRODUCTION Potential legislation concerning

More information

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) ABB MEASUREMENT & ANALYTICS APPLICATION NOTE Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) The new LGR-ICOS TM laser process analyzer from ABB provides

More information

Reformer Model-Based Inferential Properties embedded in APC

Reformer Model-Based Inferential Properties embedded in APC Reformer Model-Based Inferential Properties embedded in APC Authors: Santo Biroli, Augusto Autuori,Stefano Lodolo, Clive Beautyman Abstract ENI R&M has implemented Aspen Technology's Reformer Inferred

More information

AFPM 2018 Operations & Process Technology Summit

AFPM 2018 Operations & Process Technology Summit GASOLINE PROCESSES Alkylation 1 What are the benefits of alumina treating in sulfuric acid alkylation and HF alkylation? Has this technology been proven commercially? 2 What metallurgy works well and does

More information

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis Technical Overview 5100 ICP-OES Introduction Many laboratories are required to analyze metals

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT NFORMITY CERTIFICATE This is to certify that the EMIRAK Multi Gas Analyser /x (Hot Wet),, O 2 (Dry & Wet) & manufactured by: Signal Group Ltd Ambitech Division Regal Way Faringdon Oxon SN7 7BX

More information

Continuous Mercury Monitoring at Cement Plant

Continuous Mercury Monitoring at Cement Plant 21.07.2014 Continuous Mercury Monitoring at Cement Plant Background The production of cement klinker and lime in rotary kilns is responsible for 10.7% of mercury emissions to air (3,337 kg) according to

More information

Determination of Hydrocarbons in Environmental Samples with Spectrum Two

Determination of Hydrocarbons in Environmental Samples with Spectrum Two application NOTE FT-IR Spectroscopy Authors Ben Perston Aniruddha Pisal PerkinElmer, Inc. Shelton, CT 06484 USA Determination of Hydrocarbons in Environmental Samples with Spectrum Two Introduction The

More information

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas

Module 4 : Hydrogen gas. Lecture 29 : Hydrogen gas 1 P age Module 4 : Hydrogen gas Lecture 29 : Hydrogen gas 2 P age Keywords: Electrolysis, steam reforming, partial oxidation, storage Hydrogen gas is obtained in a very trace amount in atmosphere. It is

More information

Using Petro-SIM to Optimize an FCCU with Integrated Product Separation. Gregory Tragitt Senior Staff Consultant

Using Petro-SIM to Optimize an FCCU with Integrated Product Separation. Gregory Tragitt Senior Staff Consultant Using Petro-SIM to Optimize an FCCU with Integrated Product Separation Gregory Tragitt Senior Staff Consultant 2014 KBC Advanced PROPRIETARY Technologies plc. INFORMATION All Rights Reserved. May 2014

More information

State of the Art (SOTA) Manual for Stationary Gas Turbines

State of the Art (SOTA) Manual for Stationary Gas Turbines State of the Art (SOTA) Manual for Stationary Gas Turbines Original Date: July 1997 Revision Date: November 1999 State of New Jersey Department of Environmental Protection Air Quality Permitting Program

More information

The Use of Sensitivity Analysis and Genetic Algorithms for the Management of Catalyst Emissions from Oil Refineries

The Use of Sensitivity Analysis and Genetic Algorithms for the Management of Catalyst Emissions from Oil Refineries The Use of Sensitivity Analysis and Genetic Algorithms for the Management of Catalyst Emissions from Oil Refineries J.M. Whitcombe, R.A. Cropp, R.D. Braddock and I.E. Agranovski Faculty of Environmental

More information

Chapter 10. Flowsheet Analysis for Pollution Prevention. by Kirsten Sinclair Rosselot and David T. Allen

Chapter 10. Flowsheet Analysis for Pollution Prevention. by Kirsten Sinclair Rosselot and David T. Allen Chapter 10. Flowsheet Analysis for Pollution Prevention by Kirsten Sinclair Rosselot and David T. Allen The environmental performance of a process flowsheet depends on both the performance of the individual

More information

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR White paper WP/ANALYTICAL/002 EN ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field

More information

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control M. Raynor, H. Funke, J. Yao, T. Watanabe and R. Torres, Matheson Tri-Gas, Advanced Technology Center,

More information

FCC Regenerator Design to Minimize Catalyst Deactivation and Emissions. Steve Tragesser Shaw Energy and Chemicals Group

FCC Regenerator Design to Minimize Catalyst Deactivation and Emissions. Steve Tragesser Shaw Energy and Chemicals Group FCC Regenerator Design to Minimize Catalyst Deactivation and Emissions Steve Tragesser Shaw Energy and Chemicals Group Shaw Stone & Webster FCCs 42 RFCC/FCC/DCC Units Licensed Resid RFCCs (R2R) Other FCC/DCCs

More information

THE ROLE OF CATALYST IN FCC TROUBLESHOOTING

THE ROLE OF CATALYST IN FCC TROUBLESHOOTING FCC MANUAL 5.4 THE ROLE OF CATALYST IN FCC TROUBLESHOOTING SUMMARY Fluidized Catalytic Cracking is a complex process where problems are not easily defined or isolated. This paper presents some background

More information

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time> TruePeak TDLS200 NH 3 Slip Measurement One Background One Two Three Four Gas-Fired Installations The SCR control system must be able to perform in a range of conditions Flue gases from

More information

Pre-Combustion Technology for Coal-fired Power Plants

Pre-Combustion Technology for Coal-fired Power Plants Pre-Combustion Technology for Coal-fired Power Plants Thomas F. Edgar University of Texas-Austin IEAGHG International CCS Summer School July, 2014 1 Introduction 2 CO 2 Absorption/Stripping of Power Plant

More information

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System Introduction The objective of good laboratory practice (GLP) is to obtain accurate and precise results, using a measurement system

More information

Hydrogen Production by Non Thermal Plasma Steam Reforming of alkanes and ethanol

Hydrogen Production by Non Thermal Plasma Steam Reforming of alkanes and ethanol Hydrogen Production by Non Thermal Plasma Steam Reforming of alkanes and ethanol A. Khacef, F. Ouni, E. El Ahmar, O. Aubry, and J. M. Cormier GREMI-Polytech'Orléans, 14 rue d'issoudun, BP 6744, 4567 Orléans

More information

Grading & Guard Materials

Grading & Guard Materials Grading & Guard Materials MAXIMUM CATALYT PRTECTIN AND PTIMUM PREURE DRP MANAGEMENT INTRDUCTIN With the increased levels of heavy and nonconventional crude oils in the refinery diets, state-of the art

More information

Onsite quantitative FTIR analysis of water in turbine oil

Onsite quantitative FTIR analysis of water in turbine oil Onsite quantitative FTIR analysis of water in turbine oil Application Note Author Frank Higgins Agilent Technologies, Connecticut, USA Introduction The availability of the Agilent 5500t FTIR spectrometers,

More information

Comparison between Different Control Approaches of the UOP Fluid Catalytic Cracking Unit

Comparison between Different Control Approaches of the UOP Fluid Catalytic Cracking Unit 17 th European Symposium on Computer Aided Process Engineering ESCAPE17 V. Plesu and P.S. Agachi (Editors) 2007 Elsevier B.V. All rights reserved. 1 Comparison between Different Control Approaches of the

More information

GASOLINE FROM NATURAL GAS BY SULFUR PROCESSING

GASOLINE FROM NATURAL GAS BY SULFUR PROCESSING GASOLINE FROM NATURAL GAS BY SULFUR PROCESSING BY Erek J. Erekson R. Gopalakrishnan January 1996 Work Performed Under Contract No.: DE-AC22-93PC92114 For U.S. Department of Energy Pittsburgh Energy Technology

More information

Title: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry

Title: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry Procedure No: SOP-022 Revision No: 1.1 January 27, 2011 Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

Development of an analytical method suitable for on-site measurement of thermodynamic hydrate inhibitors in oilfield produced fluids

Development of an analytical method suitable for on-site measurement of thermodynamic hydrate inhibitors in oilfield produced fluids Development of an analytical method suitable for on-site measurement of thermodynamic hydrate inhibitors in oilfield produced fluids Fiona S. Mackay (LUX Assure), Anne-Marie Fuller (LUX Assure), Catherine

More information

Lab 6 Measurement of Ozone

Lab 6 Measurement of Ozone Georgia Institute of Technology School of Earth and Atmospheric Sciences EAS 4641 Spring 2008 Lab 6 Measurement of Ozone Purpose of Lab 6: In this lab you will measure the ambient concentration of ozone

More information

Euan Evenson Praxair, Research and Development

Euan Evenson Praxair, Research and Development Euan Evenson Praxair, Research and Development Praxair at a Glance A Fortune 300 company with 2015 sales of $11 billion A leading industrial gas company in North and South America and one of the largest

More information

Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS.

Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS. Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS. 1 Agilent Technology Leadership, the first 55 years 1957 Built components for world's first AA (as Techtron) 1971

More information

1) ABSORPTION The removal of one or more selected components from a gas mixture by absorption is probably the most important operation in the control

1) ABSORPTION The removal of one or more selected components from a gas mixture by absorption is probably the most important operation in the control 1) ABSORPTION The removal of one or more selected components from a gas mixture by absorption is probably the most important operation in the control of gaseous pollutant emissions. Absorption is a process

More information

Air pollutant emission estimation methods for E-PRTR reporting by refineries 2017 edition

Air pollutant emission estimation methods for E-PRTR reporting by refineries 2017 edition Air pollutant emission estimation methods for E-PRTR reporting by refineries 2017 edition Air pollutant emission estimation methods for E-PRTR reporting by refineries 2017 edition Prepared by the Concawe

More information

Questions. Downdraft biomass gasifier. Air. Air. Blower. Air. Syngas line Filter VFD. Gas analyzer(s) (vent)

Questions. Downdraft biomass gasifier. Air. Air. Blower. Air. Syngas line Filter VFD. Gas analyzer(s) (vent) Question 1 Questions Biomass gasification is a process where organic matter liberates flammable gases such as hydrogen (H 2 ) and carbon monoxide (CO) when heated to high temperatures. A gasifier is a

More information

ICAC MARAMA Portable Emission Analyzers

ICAC MARAMA Portable Emission Analyzers ICAC MARAMA Portable Emission Analyzers Drew Wilson ECOM America www.ecomusa.com May 19, 2011 Portable Analyzers A quick history Originally developed for combustion efficiency applications. Measured O2,

More information

Thomas G. Braga Manager, Research and Development. SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company

Thomas G. Braga Manager, Research and Development. SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company Thomas G. Braga Manager, Research and Development SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company Who is SulfaTreat? A World Leader in H 2 S Removal for More than a Decade Today

More information

Lars K. Gram. FORCE Technology. The Danish EPA's Reference Laboratory for Air Emission Monitoring.

Lars K. Gram. FORCE Technology. The Danish EPA's Reference Laboratory for Air Emission Monitoring. Lars K. Gram FORCE Technology The Danish EPA's Reference Laboratory for Air Emission Monitoring LKG@Force.dk 1 Title: International regulation on emission monitoring Sub title: How to implement PEMS as

More information

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers Advances in NOx Compliance Testing with Portable Electrochemical Analyzers LADCO Workshop: Emission Control and Measurement Technology for Industrial Sources March 24-25, 2009 Craig McKim, Emission Division

More information

ENE HELSINKI UNIVERSITY OF TECHNOLOGY PARTICULATES #2

ENE HELSINKI UNIVERSITY OF TECHNOLOGY PARTICULATES #2 PARTICULATES #2 Filter systems Wet scrubbers Cost comparison cyclone / ESP / filter High temperature high pressure particulate control Particulate emission control for vehicles see: www.hut.fi/~rzevenho/gasbook

More information

Monitoring cement plant stack emissions using FTIR

Monitoring cement plant stack emissions using FTIR ABB MEASUREMENT & ANALYTICS WHITE PAPER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measurement

More information

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique Application note Energy and fuels Authors Frank Higgins and John Seelenbinder Agilent Technologies

More information

Salt deposition in FCC gas concentration

Salt deposition in FCC gas concentration Salt Deposition in FCC Gas Concentration Units Michel Melin Director Technical Service Grace Davison Refining Technologies Europe, Middle East and Africa Colin Baillie Marketing Manager Grace Davison Refining

More information

Document No.: NOKETL / IPPC Licence No.: W

Document No.: NOKETL / IPPC Licence No.: W Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person Air Emissions Compliance Monitoring Emissions Report Air Scientific Ltd., 32 DeGranville Court,

More information

Unit I. Water Technology: REVIEW QUESTIONS. 2.what are the salts responsible for carbonate and non-carbonate hardness of

Unit I. Water Technology: REVIEW QUESTIONS. 2.what are the salts responsible for carbonate and non-carbonate hardness of Unit I Water Technology: REVIEW QUESTIONS PART-A(2 MARKS) 1.Define hardness of water. 2.what are the salts responsible for carbonate and non-carbonate hardness of water? 3. why is hardness expressed in-terms

More information

State-of-the-art concerning particle precipitation devices for residential biomass combustion systems

State-of-the-art concerning particle precipitation devices for residential biomass combustion systems ERA-NET Bioenergy - International Workshop Technologies for clean biomass combustion 20 th September 2012, Graz, Austria State-of-the-art concerning particle precipitation devices for residential biomass

More information

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC)

Title: Standard Operating Procedure for Measurement of CO in Ambient Air by Gas Filter Correlation (GFC) Procedure No: SOP-024 Revision No: 0 (new document) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

Hydrogen Sulphide and Mercaptan Removal

Hydrogen Sulphide and Mercaptan Removal Natural Gas The significance of natural gas as an energy source is increasing rapidly. Yet its discovery and exploitation are far more recent than those of oil as gas projects have begun to develop since

More information

Regulatory position paper on sulphur dioxide monitoring, comparing portable-instrumental techniques with manual methods

Regulatory position paper on sulphur dioxide monitoring, comparing portable-instrumental techniques with manual methods Regulatory position paper on sulphur dioxide monitoring, comparing portable-instrumental techniques with manual methods Dr Rick Gould, Environment Agency, Technical Advisor, Certification and Standards,

More information

FCCU NO x Reduction - SCR Retrofit. October Vice President of Engineering KTI Corporation

FCCU NO x Reduction - SCR Retrofit. October Vice President of Engineering KTI Corporation FCCU NO x Reduction - SCR Retrofit October 2011 Düsseldorf Germany Daniel Barnett Vice President of Engineering KTI Corporation 001 281.249.3546 dbarnett@kticorp.com FCCU Introduction The Fluidized Catalytic

More information

Catalyst properties and FCC operational variables effecting resistivity

Catalyst properties and FCC operational variables effecting resistivity Catalyst properties and FCC operational variables effecting resistivity By D. L. Salbilla 1. Summary Stringent regulations further limiting environmental emissions are costing domestic refiners millions

More information

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK 1) Introduction Particulate CEMs for Wet and Dry FGD applications By William Averdieck, Managing Director, PCME Ltd, UK Williama@pcme.co.uk This paper overviews the challenges of monitoring particulate

More information

WLTP-DTP Subgroup Additional Pollutants Progress Report April Progress report. Date: 17. Apr WLTP-DTP-AP, Mörsch/Astorga

WLTP-DTP Subgroup Additional Pollutants Progress Report April Progress report. Date: 17. Apr WLTP-DTP-AP, Mörsch/Astorga WLTP-DTP Subgroup Additional Pollutants Progress report Date: 17. Apr. 2012 WLTP-DTP-AP, Mörsch/Astorga 2 Additional pollutants: Request for Parameters list 1 Parameters list For NO2 2 Other AP 3 In VP2

More information

Process Gas Monitoring In Petroleum Refineries

Process Gas Monitoring In Petroleum Refineries Application Data Sheet ADS 103-2911AA01 July, 2005 Application Data Process Gas Monitoring In Petroleum Refineries APPLICATION Emerson offers several Rosemount Analytical gas analyzer technologies to meet

More information

Chemical Engineering 633

Chemical Engineering 633 Chemical Engineering 633 Combustion Processes Pollutants 1 Outline 2 Measurements Emissions index Basis Corrected Concentrations CO/unburnt hydrocarbons SO x Particles Tour baghouse 1 Concentrations 3

More information

Frequently Asked Questions

Frequently Asked Questions EUROPEAN COMMISSION DIRECTORATE-GENERAL CLIMATE ACTION Directorate A International and Climate Strategy CLIMA.A.3 - Monitoring, Reporting, Verification Frequently Asked Questions Regarding Annual Emissions

More information

Advanced Gasification, Gas Cleaning and Product Gas utilization

Advanced Gasification, Gas Cleaning and Product Gas utilization Advanced Gasification, Gas Cleaning and Product Gas utilization Gasification and Energy from Waste and Biomass March 12 th, 2014 Presented by: Martin van t Hoff Presentation contents Royal Dahlman & ECN,

More information

Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, NO formation

Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, NO formation Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, introduce an innovative piece of technology that was able to help a Californian refinery reduce its NOX emissions R efinery fuels present manifold

More information

Comprehensive Re-utilization of Particle Pollutants from FCC Unit

Comprehensive Re-utilization of Particle Pollutants from FCC Unit Comprehensive Re-utilization of Particle Pollutants from FCC Unit Liang Changfeng is the director of the HSE management department for Qingdao Huicheng Environmental Technology Co., Ltd. He has been with

More information

ASTM D19.06 SUBCOMMITTEE

ASTM D19.06 SUBCOMMITTEE ASTM D19.06 SUBCOMMITTEE STUDY REPORT FROM THE TESTING OF ADDITIONAL INDUSTRIAL WASTEWATER MATRICES IN SUPPORT OF ASTM STANDARD D7575 FOR USEPA s RECONSIDERATION OF THIS METHOD IN THE Prepared for: United

More information

Easy ways to boost. your productivity.

Easy ways to boost. your productivity. Refining Easy ways to boost your productivity. Fine-tuning key links in your process flow can give you the tools to optimise capacity, reliability and flexibility for a healthier bottom line. APPLICATION

More information

Problems Recorded on the Appropriateness of a Pilot Plant for Production of Second Generation Biofuels by Fast Pyrolysis

Problems Recorded on the Appropriateness of a Pilot Plant for Production of Second Generation Biofuels by Fast Pyrolysis Problems Recorded on the Appropriateness of a Pilot Plant for Production of Second Generation Biofuels by Fast Pyrolysis Fabio Mendes 1, Marco Figueiredo 2 * 1 Centro de Pesquisas Leopoldo Miguez de Melo,

More information

Method Abstract. Flow Solution Ammonia in Seawater, USEPA by SFA

Method Abstract. Flow Solution Ammonia in Seawater, USEPA by SFA Scope Summary Interferences Performance Specifications Ammonia in Seawater, USEPA by SFA This method is used for the determination of ammonia in estuarine and coastal waters (seawater) according to USEPA

More information

Remote Sensing Studies Demonstrate that Refinery Emissions are Underestimated.

Remote Sensing Studies Demonstrate that Refinery Emissions are Underestimated. Remote Sensing Studies Demonstrate that Refinery Emissions are Underestimated. Emissions from tanks, wastewater treatment plants, and flares cannot be measured using traditional methods because the releases

More information

Report No. 32 HYDROGEN. December A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE PARK, CALIFORNIA

Report No. 32 HYDROGEN. December A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE PARK, CALIFORNIA Report No. 32 HYDROGEN by RICHARD G. DENNEY December 1967 A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE I I MENLO PARK, CALIFORNIA CONTENTS 1 2 3 4 5 6 INTRODUCTION....

More information

Cansolv Technologies Inc.

Cansolv Technologies Inc. 6 C 16 S Cansolv Technologies Inc. About Cansolv Cansolv Technologies Incorporated was formed in 1997 to commercialize and market the CANSOLV SO Scrubbing System developed at Union Carbide Canada. Since

More information

Cansolv Technologies Inc. Air and Waste Management Association South Coast AQMD May 14, Rick Birnbaum

Cansolv Technologies Inc. Air and Waste Management Association South Coast AQMD May 14, Rick Birnbaum A Versatile SO 2 Scrubbing Process For Industrial SO 2 Emission Control Air and Waste Management Association South Coast AQMD May 14, 2008 Rick Birnbaum rick.birnbaum@cansolv.com OUTLINE Gas Absorption

More information

Modelling of the oxy-combustion fluid catalytic cracking units

Modelling of the oxy-combustion fluid catalytic cracking units Antonio Espuña, Moisès Graells and Luis Puigjaner (Editors), Proceedings of the 27 th European Symposium on Computer Aided Process Engineering ESCAPE 27 October 1 st - 5 th, 2017, Barcelona, Spain 2017

More information

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control Jim Feather ExxonMobil Research & Engineering OLI 23 rd User Conference October 5-6, 2005 Presentation Outline Challenges

More information

HILASE - QUALITY CONTROL INSTRUMENT

HILASE - QUALITY CONTROL INSTRUMENT HILASE - QUALITY CONTROL INSTRUMENT The Hilase is a reliable and virtually maintenance free Process Analyser for the measurement of H 2 S, H 2 O, CO 2, CH 4, C 2 H 6, Methanol/Ethanol, COS, Ammonia, etc

More information

Autothermal Reforming of Hydrocarbon Fuels

Autothermal Reforming of Hydrocarbon Fuels Autothermal Reforming of Hydrocarbon Fuels Harald Zeman, Michael Url, Hermann Hofbauer Institute of Chemical Engineering, Vienna University of Technology Getreidemarkt 9/166, A-1060 Vienna, harald.zeman@tuwien.ac.at

More information

OPTIMISATION OF ANGLO PLATINUM S ACP ACID PLANT CATALYTIC CONVERTER. M. K. SICHONE Anglo Platinum, ACP, Kroondal, South Africa

OPTIMISATION OF ANGLO PLATINUM S ACP ACID PLANT CATALYTIC CONVERTER. M. K. SICHONE Anglo Platinum, ACP, Kroondal, South Africa OPTIMISATION OF ANGLO PLATINUM S ACP ACID PLANT CATALYTIC CONVERTER Anglo Platinum, ACP, Kroondal, South Africa ABSTRACT Anglo Platinum s Waterval smelting complex based in South Africa operates the Anglo

More information