Airborne Mould Spore Assessment and Inspections

Size: px
Start display at page:

Download "Airborne Mould Spore Assessment and Inspections"

Transcription

1 Sterling IAQ Consultants Ltd. Suite Mainland Street Vancouver, B.C., V6B 5L1 (t) (f) Airborne Mould Spore Assessment and Inspections Sungod Recreation Centre th Street, Delta, B.C. Sterling IAQ Consultants Ltd. Project #: Presented to: The Corporation of Delta 4500 Clarence Taylor Crescent Delta, B.C., V4K 3E2 Attention: Greg Scott, Deputy Director-Development March 18, 2014 Indoor air quality Mould, Occupational Hygiene Hazardous materials

2 Sungod Recreation Centre, Delta Page INTRODUCTION Sterling IAQ Consultants Ltd. (Sterling IAQ) was retained by The Corporation of Delta to carry out an airborne mould spore assessment, tape lift sampling and visual inspections of the Sungod Recreation Centre located at th Street, Delta, BC (subject building). In September of 2013, a building envelope assessment was conducted of an exterior parapet wall located above the pool area (subject area) by RDH Building Engineering Ltd. and their report was delivered on October 22, In their report, recommendations were offered to address the parapet wall that was heavily damaged and rotted. Sterling IAQ was originally contacted on March 12, 2014 to discuss the assessment of mould and how this exterior mould issue could potentially affect the indoor environment. On March 13, 2014, a formal request was made to Sterling IAQ to conduct a mould assessment of the indoor environment and the parapet wall. On the morning of March 14, 2014, Sterling IAQ was on site for the assessment. 2.0 SCOPE OF WORK Sterling IAQ Consultants Ltd. conducted the following activities within the subject area: 1. Collection of airborne mould spore samples (4 indoor samples and 3 outdoor samples); 2. Environmental surface tape-lift sample on the parapet wall area to determine the presence and the type of mould; 3. Inspection of the subject area to determine extent of mould issue; 4. The submission of all gathered samples to a qualified independent laboratory for analysis; 5. Preparation of a complete written report including lab results to the Corporation of Delta; 3.0 METHODOLOGY Air sampling for mould spores was conducted with a Zefon Bio-Pump calibrated to 15 litres per minute. This pump was configured to draw air through an Air-O- Cell sampling cassette for a period of 5 minutes. The Air-O-Cell is a unique airsampling cassette specifically designed for the rapid collection of a wide range of airborne aerosols including mould spores. The Air-O-Cell collects both viable and non-viable mould spores, which provide a much broader overview of potential allergens & contaminants than conventional viable sampling techniques.

3 Sungod Recreation Centre, Delta Page 2 In order to provide a comparative reference values, outdoor air sample were also collected. For this assessment, there were 3 outdoor samples collected. One was collected from the parking lot area to represent a typical outdoor sample. Another outdoor sample was collected from the roof area ½ way between the subject area (damaged parapet wall) and the main air-handling unit for the building. A third outdoor sample was collected along the tree line near the parking lot to represent outdoor conditions near plants, trees and other rotting organic materials. Upon completion of our site investigation, all Air-O-Cell sample cassettes were forwarded to Kitospore in Surrey for analysis. Their laboratory report is attached. 4.0 INDOOR AIR QUALITY GUIDELINES MOULD GUIDELINES In the province of British Columbia, WorksafeBC through the Occupational Health & Safety Regulation enforces workplace health and safety. Within this Regulation, there are no specific provisions for how to assess potential mould contamination in buildings nor are established permissible levels for mould in air presented. However, WorksafeBC has formulated Guidelines for Section 4.79 of the Regulation entitled - Moulds and Indoor Air Quality. Air sampling data interpretation Since individual response to mould spores in air varies dramatically between persons and between different geographical regions, there are various guidelines available across North America for acceptable levels of mould spores in air. The American Conference of Governmental Industrial Hygienists (ACGIH) suggests that the concentrations and types of airborne mould indoors should be similar to or lower than outdoors. The same is suggested by the United States Occupational Safety and Health Administration (OSHA). Since the ACGIH/OSHA guidelines depend solely on outdoor concentrations and because outdoor levels are affected significantly by time of year, time of day, weather conditions, etc., it is suitable that other guidelines be presented in some situations. The American Academy of Allergy, Asthma and Immunology / National Allergy Bureau have established a set of atmospheric total mould spore concentrations presented below.

4 Sungod Recreation Centre, Delta Page 3 Table 4.1 American Academy of Allergy, Asthma and Immunology / National Allergy Bureau Mould Spore Guidelines 2002 Total Mould spore concentration (spores/m 3 ) Ranking (risk) Symptoms Absent Zero No symptoms 1 4,224 Low Only individuals extremely sensitive to mould spores will experience symptoms 4,225 7,799 Moderate Many individuals sensitive to mould spores will experience symptoms 7,800 24,999 High Most individuals with any sensitivity to mould spores will experience symptoms > 25,000 Very High Almost all individuals with any sensitivity at all to mould spores will experience symptoms. Extremely sensitive people could have severe symptoms. spores/m3 mould spores per cubic meter of air 5.0 RESULTS AND DISCUSSION INSPECTIONS AND OBSERVATIONS This assessment was triggered by concerns that the rotted areas of an exterior rooftop parapet wall over the pool (subject area) that contains mould posed a risk to the guests and/or workers of the subject building. In Appendix B, we have presented an aerial view of the site with the yellow rectangle showing the location of the parapet wall. Our exterior inspections found that there was notable wood rot issue along the entire exterior wall sheathing of the parapet wall. Between this exterior rotted sheathing and the wall that adjoins the pool deck was a void space. On the actual wall that adjoined the pool deck, visible rot or mould growth was not observed as the rot and mould was only observed on the exterior sheathing.

5 Sungod Recreation Centre, Delta Page 4 Photo 1 exterior of parapet wall Photo 2 Roof level, showing air sample location M2 NOTE: this sample shows the main air-handling unit in the background and sample M2 was collected ½ between subject area and this building air intake

6 Sungod Recreation Centre, Delta Page 5 Photo 3 Indoors showing air sample M3, Staff offices centre Photo 4 Indoors showing air sample M5, Pool Deck, directly below subject area Airborne Mould Spore Sampling The results of the airborne mould spore samples collected are presented in Table 5.1. The laboratory report from Kitospore is attached in Appendix A at the end of this report.

7 Sungod Recreation Centre, Delta Page 6 Review of the total mould spore results (bottom row of Table 5.1) found the indoor levels to be generally below all the various outdoor levels measured and therefore were considered acceptable. The outdoor sample total mould spore results from the roof between the subject area and the main air-handling unit were very low (385.7 spores/m 3 ) and two of the indoor total mould spore results were actually higher than this amount (offices spores/m 3 and reception/snack bar 532 spores/m 3 ). However, indoor mould spore results are influenced by many factors as air enters through doorways and windows and sometimes tracked in on clothing. So when we look at the indoor total mould spore results as a whole and compare to the 3 different outdoor results, we can conclude that indoor results were consistent with outside and therefore considered acceptable. The total indoor mould spore levels fell within the low-risk range for allergy and asthma sufferers as denoted in table 4.1 of this report. In this low-risk range, only individuals extremely sensitive to mould spores could experience symptoms. Review of the individual mould spore results found indoor moulds to be consistent with or lower than outdoor results. The primary concern was that mould from the rotted parapet wall was adversely affecting the indoor air quality of the pool and recreation centre. So if we review the results of the tape lift sample collected from the worst part of the rotted parapet wall, we see the results (from the lab report in Appendix A) included the following: Dirt/dust/debris 90% Cladosporium herbarum 10% This tape lift result suggested that although the wall was severely rotted, not much actual mould growth was present. Furthermore, the mould detected on the parapet wall was the most commonly detected mould in air samples common both indoors and outdoors. If we specifically look at Cladosporium air sampling results, our outdoor average between the 3 samples was spores/m 3. Our indoor Cladosporium results ranged from 26.6 spores/m 3 to spores/m 3 and averaged 83.1 spores/m 3. Therefore, we can conclude that indoor Cladosporium results had not been adversely affected by the observed outdoor source (rotted outdoor parapet wall).

8 Sungod Recreation Centre, Delta Page 7 Table 5.1 Airborne Mould Spore Sample Results March 14, 2014 Sungod Recreation Centre, th Street, Delta Mould Taxa Found M3 Staff offices M4 Reception snack bar M5 Pool deck M6 Gym and day care M7 Outdoors parking lot M2 Outdoors roof near air intake M1 Outdoors near trees and leaves Alternaria Arthrinium Ascospores Aureobasidium Basidiospores Bipolaris/Drechslera gp Botrytis Chaetomium Cladosporium Curvularia Epicoccum Fusarium Myrothecium Nigrospora Other Colorless Penicillium/Aspergillius Pithomyces Rusts Smuts,Peric.,Myxomy Stachybotrys chartarum Stemphylium Torula herbarum Ulocladium Unknown Zygomycetes Background Debris* Total Spores/m³ All results in spores per cubic meter of air (spores/m 3 )

9 Sungod Recreation Centre, Delta Page CONCLUSIONS AND RECOMMENDATIONS The following conclusions are offered: 1. The rotted parapet wall was located on the exterior of the building. 2. A tape lift sample collected from the most heavily damaged area of this parapet wall showed the following results which demonstrated that very little mould was actually present: a. Dirt/dust/debris 90% b. Cladosporium herbarum 10% 3. The main air-handling unit for the building was located approximately 20 meters away from the rotted parapet wall. 4. On the actual wall section that directly adjoined the pool area, no mould or rot was observed. 5. Indoor airborne mould spores results demonstrated that concentrations were within industry standard guidelines and that the indoor air quality was not adversely affected by the rot/mould observed on the exterior parapet wall. Despite there being no issue observed that affected the indoor air quality of the subject building, the following recommendations are offered: 1. When the repair work for the parapet wall is being planned, efforts should be taken to ensure particulate from that work (wood dust, mould spores, etc.) does not affect the indoor environment. This may be accomplished by using poly sheeting on the interior wall that adjoins the pool area to seal that wall section. 2. Additionally, demolition work on this parapet wall should be done in such a way as to ensure particulate (wood duct, mould spores, etc.) does not get entrained into the air intake, which is located approximately 20 meters away.

10 Sungod Recreation Centre, Delta Page GENERAL STATEMENT OF LIMITATIONS Sincerely, This report is intended and restricted for the sole use of The Corporation of Delta (The Client). Any use, interpretation or reliance upon this report/assessment by anyone other than The Client is at the sole risk of that party, and Sterling IAQ Consultants Ltd. shall have no liability for such unauthorized use, interpretation, or reliance. Sterling IAQ Consultants Ltd. makes no representations, warranties, or guarantees as to any given sample (whether it be obtained by Sterling IAQ Consultants Ltd. or by (The Client) being representative of any given contaminant, handled, or otherwise managed by The Client. With regard to site assessment work, Sterling IAQ Consultants Ltd. make no representations, warranties, or guarantees that the points selected for inspection are in any way representative of the entire site. All liability is limited to the fee charged. We trust that this report meets with your requirements. We thank you for the opportunity to be of service and if you have any questions, please contact the undersigned at (604) Sterling IAQ Consultants Ltd. Per: Michael Glassco, ROHT President michael@sterlingiaqconsultants.com

11 Appendix A Laboratory Results - Mould Indoor air quality Mould, Occupational Hygiene Hazardous materials

12 nd Street Suite#315 Surrey, B.C V3R 8X8 Ph:(604) Fax:(604) Kitospore Enterprises Environmental Mould Specialists Certificate of Laboratory Analysis Client: Sterling IAQ Consultants Ltd. Lab ID #: A Client ID: Ster C.O.C.#: E Date: March 17, 2014 Project #: Sample Type: 75L & Tape Lift Submitted by: Bob Date and Time Submitted: Mar.14/14-4:30PM Results comply with the following: Standard Test Method for Categorization and Quantification of Airborne Fungal Structures in an Inertial Impaction Sample by Optical Microscopy ASTM International Committee on Air Quality May 1, 2009 Guidelines on Assessment and Remediation of Fungi in Indoor Environment, New York City Department of Health, Bureau of Environment & Occupational Disease Epidemiology, April Fungal Contamination in Public Buildings: A Guide to Recognition and Management, Federal-Provincial Committee on Environmental and Occupational Health, June Indoor Air Quality in Office Buildings: A Technical Guide, Report of the Federal Provincial Advisory Committee on Environmental and Occupational Health, Sampling and Identifying Allergenic Pollens and Moulds -Grant E. Smith-Blewstone Press, San Antonio Texas. Illustrated Dictionary of Mycology The American Phytopathological Society-2000 Moulds-their Isolation, Cultivation and Identification - David Malloch, University of Toronto Press And those offered by the McCrone Research Institute of Chicago. Health Canada Fungal Contamination in Public Buildings: Health Effects and Investigation Methods. Kim Tomms B.Sc. Disclosure comment: This report has been prepared for the sole benefit of Sterling IAQ Consultants Ltd.. This report may not be relied upon without the express written consent of Kitospore and Sterling IAQ Consultants Ltd.. Any use that a third party makes of this report, or any reliance on the decisions made based on this report, are the sole responsibility of that third party. Kitospore accepts no responsibility for damages, if any, that are suffered by any third party as a result of decisions made or actions taken based on this report. The conclusions that are presented in this report are to the absolute best judgement of the certified analyst. It should not be inferred that other potential contaminants are not present. Page 1 of 5 Confidential *All samples are completed using slit sample techniques while enumerating 100% of each samples trace. Detection Limit is 13.3

13 Kitospore Enterprises Client: Sterling IAQ Consultants Ltd. Lab ID #: A Client ID: Ster C.O.C.#: E Date: March 17, 2014 Project #: Sample Volume (liters): 75L Attn: Mike OUTSIDE-Tree Line Roof Top Staff Offices Raw Ct % Spores/M 3 Raw Ct % Spores/M 3 Raw Ct % Spores/M 3 Alternaria 0 0% 0 0 0% 0 0 0% 0 Arthrinium 0 0% 0 0 0% 0 0 0% 0 Ascospores 12 11% % 0 0 0% 0 Aureobasidium 0 0% 0 0 0% 0 0 0% 0 Basidiospores 38 34% % % Bipolaris/Drechslera gp. 0 0% 0 0 0% 0 0 0% 0 Botrytis 0 0% 0 0 0% 0 0 0% 0 Chaetomium 0 0% 0 0 0% 0 0 0% 0 Cladosporium 31 28% % % Curvularia 0 0% 0 0 0% 0 0 0% 0 Epicoccum 6 5% % 0 0 0% 0 Fusarium 1 1% % 0 0 0% 0 Myrothecium 0 0% 0 0 0% 0 0 0% 0 Nigrospora 0 0% 0 0 0% 0 0 0% 0 Other Colorless 0 0% 0 0 0% 0 0 0% 0 Penicillium/Aspergillius 16 14% % % 93.1 Pithomyces 1 1% % 0 0 0% 0 Rusts 0 0% 0 0 0% 0 0 0% 0 Smuts,Peric.,Myxomy. 5 4% % % 0 Stachybotrys chartarum 0 0% 0 0 0% 0 0 0% 0 Stemphylium 2 2% % 0 0 0% 0 Torula herbarum 0 0% 0 0 0% 0 0 0% 0 Ulocladium 0 0% 0 0 0% 0 0 0% 0 Unknown 0 0% 0 0 0% 0 0 0% 0 Zygomycetes 0 0% 0 0 0% 0 0 0% 0 Background Debris* Total Spores/M % % % Skin Cells 0 Skin Cells <1 Skin Cells 3+ Out/Supply Vent Dust Out/Supply Vent Dust Out/Supply Vent Dust Very Low Low Low Mycelial Fragments/M 3 Mycelial Fragments/M 3 Mycelial Fragments/M or 79.8/M 3 9 or 119.7/M 3 Page 2 of 5 Confidential *All samples are completed using slit sample techniques while enumerating 100% of each samples trace. Detection Limit is 13.3

14 Kitospore Enterprises Client: Sterling IAQ Consultants Ltd. Lab ID #: A Client ID: Ster C.O.C.#: E Date: March 17, 2014 Project #: Sample Volume (liters): 75L Attn: Mike Reception Area Pool Deck-Central Gymnasium Raw Ct % Spores/M 3 Raw Ct % Spores/M 3 Raw Ct % Spores/M 3 Alternaria 0 0% 0 0 0% 0 0 0% 0 Arthrinium 0 0% 0 0 0% 0 0 0% 0 Ascospores 0 0% 0 0 0% 0 0 0% 0 Aureobasidium 0 0% 0 0 0% 0 0 0% 0 Basidiospores 24 60% % % Bipolaris/Drechslera gp. 0 0% 0 0 0% 0 0 0% 0 Botrytis 0 0% 0 0 0% 0 0 0% 0 Chaetomium 0 0% 0 0 0% 0 0 0% 0 Cladosporium 6 15% % % 66.5 Curvularia 0 0% 0 0 0% 0 0 0% 0 Epicoccum 0 0% 0 0 0% 0 0 0% 0 Fusarium 0 0% 0 0 0% 0 0 0% 0 Myrothecium 0 0% 0 0 0% 0 0 0% 0 Nigrospora 0 0% 0 0 0% 0 0 0% 0 Other Colorless 0 0% 0 0 0% 0 0 0% 0 Penicillium/Aspergillius 10 25% % % Pithomyces 0 0% 0 0 0% 0 0 0% 0 Rusts 0 0% 0 0 0% 0 0 0% 0 Smuts,Peric.,Myxomy. 0 0% 0 0 0% 0 0 0% 0 Stachybotrys chartarum 0 0% 0 0 0% 0 0 0% 0 Stemphylium 0 0% 0 0 0% 0 0 0% 0 Torula herbarum 0 0% 0 0 0% 0 0 0% 0 Ulocladium 0 0% 0 0 0% 0 0 0% 0 Unknown 0 0% 0 0 0% 0 0 0% 0 Zygomycetes 0 0% 0 0 0% 0 0 0% 0 Background Debris* Total Spores/M % % % Skin Cells 4+ Skin Cells 1+ Skin Cells 1+ Out/Supply Vent Dust Out/Supply Vent Dust Out/Supply Vent Dust Low Low Low Mycelial Fragments/M 3 Mycelial Fragments/M 3 Mycelial Fragments/M 3 8 or 106.4/M Page 3 of 5 Confidential *All samples are completed using slit sample techniques while enumerating 100% of each samples trace. Detection Limit is 13.3

15 Kitospore Enterprises Client: Sterling IAQ Consultants Ltd. Lab ID #: A Client ID: Ster C.O.C.#: E Date: March 17, 2014 Project #: Sample Volume (liters): 75L Attn: Mike OUTSIDE-AMB-Parking Lot Raw Ct % Spores/M 3 Alternaria 0 0% 0 Arthrinium 0 0% 0 Ascospores 17 15% Aureobasidium 0 0% 0 Basidiospores 44 38% Bipolaris/Drechslera gp. 0 0% 0 Botrytis 0 0% 0 Chaetomium 0 0% 0 Cladosporium 29 25% Curvularia 0 0% 0 Epicoccum 3 3% 39.9 Fusarium 2 2% 26.6 Myrothecium 0 0% 0 Nigrospora 0 0% 0 Other Colorless 0 0% 0 Penicillium/Aspergillius 14 12% Pithomyces 2 2% 26.6 Rusts 0 0% 0 Smuts,Peric.,Myxomy. 6 5% 79.8 Stachybotrys chartarum 0 0% 0 Stemphylium 0 0% 0 Torula herbarum 0 0% 0 Ulocladium 0 0% 0 Unknown 0 0% 0 Zygomycetes 0 0% 0 Background Debris* Total Spores/M % Skin Cells 0 Out/Supply Vent Dust Very Low Mycelial Fragments 0 Pollen 166 Page 4 of 5 Confidential *All samples are completed using slit sample techniques while enumerating 100% of each samples trace. Detection Limit is 13.3

16 Kitospore Enterprises Client: Sterling IAQ Consultants Ltd. Lab ID #: A Client ID: Ster C.O.C.#: E Date: March 17, 2014 Project #: Sample Type: Tape Lift Attn: Mike The Following Mould Spores were Observed by Tape Lift: T-1 Inside Exhaust Plenum-Roof 1) Dirt/Dust/Debris (90%) 2) Cladosporium herbarum (10%) No other mould spores were found. Page 5 of 5 Confidential *All samples are completed using slit sample techniques while enumerating 100% of each samples trace. Detection Limit is 13.3

17 Appendix B Site Plan subject area noted by yellow rectangle Indoor air quality Mould, Occupational Hygiene Hazardous materials

S outhwest GEOSCIENCE. Analytical Results/Chain of Custody

S outhwest GEOSCIENCE. Analytical Results/Chain of Custody S outhwest GEOSCIENCE Analytical Results/Chain of Custody Steve Moody Micro Services, LLC 2051 Valley View Lane Farmers Branch, TX 75234 Phone: (972) 241-8460 IAQ Mold Report Summary DSHS License No.:

More information

Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL f: t:

Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL f: t: Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL 35244 t: 205.986.0270 Decatur 717 Highway 67 South Suite 26 Decatur, AL 35603 t: 256.353.6222 Florence 4050 Helton Drive Suite 111 Florence, AL 35633

More information

Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL f: t:

Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL f: t: Birmingham 2080 Valleydale Road Suite 16 Birmingham, AL 35244 t: 205.986.0270 Decatur 717 Highway 67 South Suite 26 Decatur, AL 35603 t: 256.353.6222 Florence 4050 Helton Drive Suite 111 Florence, AL 35633

More information

No dry drains/traps were found, eliminating a potentially concern for odors.

No dry drains/traps were found, eliminating a potentially concern for odors. January 5, 2017 Ms. Alix Zapolski Zapolski Real Estate, LLC. 501 Washington Street Durham, NC 27701 Re: Limited Indoor Air Quality Assessment Women s Restroom 137 E. Franklin Street, Chapel Hill, NC UNC

More information

Professional remediation of the school began on the weekend of October 5, 2013 and is due to continue until the entire building can be remediated.

Professional remediation of the school began on the weekend of October 5, 2013 and is due to continue until the entire building can be remediated. 1805 Atlantic Avenue Manasquan, New Jersey 08736 Tel: (732) 223-2225 www.brinkenv.com November 4, 2013 Mr. Robert Vogel, Facilities Manager Brick Township Public Schools 346 Chambers Bridge Road Brick,

More information

Report of Limited Indoor Air Quality Services

Report of Limited Indoor Air Quality Services Report of Limited Indoor Air Quality Services Lincoln School 1601 State Street Harrisburg, Pennsylvania 17103 Prepared For: Harrisburg School District 1601 State Street Harrisburg, Pennsylvania 17103 February

More information

Report of Limited Indoor Air Quality Services

Report of Limited Indoor Air Quality Services Report of Limited Indoor Air Quality Services 301 Hale Street Harrisburg, Pennsylvania 17104 Prepared For: Harrisburg School District 1601 State Street Harrisburg, Pennsylvania 17103 February 2015 February

More information

DATE: October 5, TO: Shawn Barr, Director. SUBJECT: Facility Services - IAQ - Air Test results - Jason Hughes' Office

DATE: October 5, TO: Shawn Barr, Director. SUBJECT: Facility Services - IAQ - Air Test results - Jason Hughes' Office DATE: October 5, 2017 TO: Shawn Barr, Director SUBJECT: Facility Services - IAQ - Air Test results - Jason Hughes' Office On Monday 10/2, Apex-Titan Air tested Jason Hughes Office. It is typically assumed

More information

Visible Mold (VM) and visible water damage under cabinet on the east wall

Visible Mold (VM) and visible water damage under cabinet on the east wall Liberty Occupational Health Management, Inc. E. 9 th St. Tulsa, Oklahoma 5 9..56 www.libertyohm.com 9..569 (fax) April 6, 0 Mr. Marty Foutch Facilities Director Bixby Public Schools 09 N. Armstrong Bixby,

More information

DATE: June 4, TO: Randall Holder, Associate Principal

DATE: June 4, TO: Randall Holder, Associate Principal DATE: June 4, 2018 TO: Randall Holder, Associate Principal SUBJECT: Dale Jackson Career Center - IAQ - Air Test Results - Hallway Outside Wood Manufacturing and Tech On Thursday 5/24, Apex-Titan Air tested

More information

TN Tatem Middle School Indoor Air Quality Assessment September 2016

TN Tatem Middle School Indoor Air Quality Assessment September 2016 TN Tatem Middle School Indoor Air Quality Assessment September 2016 Completed by Island Air Quality Services P.O. Box SN139 Southampton SNBX Bermuda Table of Contents 1 Report Summary... 1 2 Introduction

More information

DATE: October 30, TO: Curtis Martin, Principal. SUBJECT: Hicks ES - IAQ - Air Test Report - Rooms E-209 & E-222

DATE: October 30, TO: Curtis Martin, Principal. SUBJECT: Hicks ES - IAQ - Air Test Report - Rooms E-209 & E-222 DATE: October 30, 2018 TO: Curtis Martin, Principal SUBJECT: Hicks ES - IAQ - Air Test Report - Rooms E-209 & E-222 On Thursday 10/25, Apex-Titan Air tested Rooms E-209 and E-222. It is typically assumed

More information

Post Remediation Testing Site Evaluation with Environmental Sampling

Post Remediation Testing Site Evaluation with Environmental Sampling Nationwide Locations Locally Served Corporate Headquarters: 7700 Congress Avenue Suite 1119 Boca Raton, FL 33487 Industrial Hygiene IAQ/Mold Assessments Water Loss Projects Restoration Project Mgmt Post

More information

DATE: February 28, TO: Robin Fry, Principal. SUBJECT: Polser ES - IAQ - Air Test - Room 200, 210 & Hallway outside 210

DATE: February 28, TO: Robin Fry, Principal. SUBJECT: Polser ES - IAQ - Air Test - Room 200, 210 & Hallway outside 210 DATE: February 28, 2014 TO: Robin Fry, Principal SUBJECT: Polser ES - IAQ - Air Test - Room 200, 210 & Hallway outside 210 I received your E-mail on February 24, in regards to Room 210. When we looked

More information

DATE: September 6, TO: Tim Greenwell, Principal. SUBJECT: Liberty ES - IAQ Air Test Results - Room 423

DATE: September 6, TO: Tim Greenwell, Principal. SUBJECT: Liberty ES - IAQ Air Test Results - Room 423 DATE: September 6, 2017 TO: Tim Greenwell, Principal SUBJECT: Liberty ES - IAQ Air Test Results - Room 423 On Tuesday 8/29, Apex-Titan Air tested Rooms 423. It is typically assumed that indoor spore levels

More information

DATE: May 13, TO: Patricia Cuckler, Principal. SUBJECT: Hedrick ES - IAQ - Air Test Results - Room 206

DATE: May 13, TO: Patricia Cuckler, Principal. SUBJECT: Hedrick ES - IAQ - Air Test Results - Room 206 DATE: May 13, 2014 TO: Patricia Cuckler, Principal SUBJECT: Hedrick ES - IAQ - Air Test Results - Room 206 On Wednesday 5/7, SWG Air tested the Room 206. It is typically assumed that indoor spore levels

More information

Report of Limited Indoor Air Quality Services

Report of Limited Indoor Air Quality Services Report of Limited Indoor Air Quality Services Camp Curtin School 2900 North 6th Street Harrisburg, Pennsylvania 17110 Prepared For: Harrisburg School District 1601 State Street Harrisburg, Pennsylvania

More information

DATE: December 10, TO: Jim Baker, Principal. SUBJECT: DeLay MS - IAQ - Request for Air Test - Room 222

DATE: December 10, TO: Jim Baker, Principal. SUBJECT: DeLay MS - IAQ - Request for Air Test - Room 222 DATE: December 10, 2013 TO: Jim Baker, Principal SUBJECT: DeLay MS - IAQ - Request for Air Test - Room 222 Received your E-mail this morning 12/10, and set up Work Order #172809: We had a leak in a class

More information

Post Remediation Testing Site Evaluation with Environmental Sampling

Post Remediation Testing Site Evaluation with Environmental Sampling Nationwide Locations Locally Served Corporate Headquarters: 7700 Congress Avenue Suite 1119 Boca Raton, FL 33487 Industrial Hygiene IAQ/Mold Assessments Water Loss Projects Restoration Project Mgmt Post

More information

DATE: September 29, TO: Michael Wetchensky, Assistant Principal. SUBJECT: Rockbrook ES - IAQ - Initial Contact - Room 511

DATE: September 29, TO: Michael Wetchensky, Assistant Principal. SUBJECT: Rockbrook ES - IAQ - Initial Contact - Room 511 DATE: September 29, 2016 TO: Michael Wetchensky, Assistant Principal SUBJECT: Rockbrook ES - IAQ - Initial Contact - Room 511 This morning 9/29, I was following up on W.O. #334260: The room smells of mildew

More information

DATE: May 27, TO: Sam Russell, Director. SUBJECT: Administration - IAQ - Initial Contact - Suite 225-Copy Room

DATE: May 27, TO: Sam Russell, Director. SUBJECT: Administration - IAQ - Initial Contact - Suite 225-Copy Room DATE: May 27, 2015 TO: Sam Russell, Director SUBJECT: Administration - IAQ - Initial Contact - Suite 225-Copy Room This morning 5/27, I received Work Order 220274: Suite 225 -The carpet in the copier room

More information

April 4, AHERA / Environmental Inspector Environmental Safety Office Old Marlboro Pike Upper Marlboro, MD 20772

April 4, AHERA / Environmental Inspector Environmental Safety Office Old Marlboro Pike Upper Marlboro, MD 20772 April 4, 2017 Mr. Alex Baylor AHERA / Environmental Inspector Environmental Safety Office 13306 Old Marlboro Pike Upper Marlboro, MD 20772 via email: alex.baylor@pgcps.org RE: Indoor Air Quality (IAQ)

More information

DATE: September 5, TO: Chris Mattingly, Principal. SUBJECT: Briarhill MS - IAQ - Air Test Results - Room 307

DATE: September 5, TO: Chris Mattingly, Principal. SUBJECT: Briarhill MS - IAQ - Air Test Results - Room 307 DATE: September 5, 2017 TO: Chris Mattingly, Principal SUBJECT: Briarhill MS - IAQ - Air Test Results - Room 307 On Tuesday 8/29, Apex-Titan Air tested Rooms 307. It is typically assumed that indoor spore

More information

December 28, Lewisville Independent School District 340 Lake Haven Lewisville, Texas Attn: Mr. Paul Siddall

December 28, Lewisville Independent School District 340 Lake Haven Lewisville, Texas Attn: Mr. Paul Siddall December 28, 2015 Lewisville Independent School District 340 Lake Haven Lewisville, Texas 75057 Attn: Mr. Paul Siddall Re: Limited Mold Assessment Services Prairie Trail Elementary School Room 113 5555

More information

DATE: March 21, TO: Martha Gooding, Principal. SUBJECT: Ethridge ES - IAQ - Initial contact - Room A-5

DATE: March 21, TO: Martha Gooding, Principal. SUBJECT: Ethridge ES - IAQ - Initial contact - Room A-5 DATE: March 21, 2014 TO: Martha Gooding, Principal SUBJECT: Ethridge ES - IAQ - Initial contact - Room A-5 On Tuesday 3/18, I received W.O. #180591: In A5 the teacher has mentioned that in the morning

More information

INTRODUCTION: METHODOLOGY: November 4, Mr. Tom Heinz 353 West Sawgrass Dakota Dunes, SD 57049

INTRODUCTION: METHODOLOGY: November 4, Mr. Tom Heinz 353 West Sawgrass Dakota Dunes, SD 57049 November 4, 2011 Mr. Tom Heinz 353 West Sawgrass Dakota Dunes, SD 57049 Re: Project #: 4004-050 353 West Sawgrass, Dakota Dunes SD Microbial Clearance Testing INTRODUCTION: This report presents the findings

More information

INTRODUCTION: METHODOLOGY: November 11, Mr. Tim Squier 487 Deerfield Dakota Dunes, SD 57049

INTRODUCTION: METHODOLOGY: November 11, Mr. Tim Squier 487 Deerfield Dakota Dunes, SD 57049 November 11, 2011 Mr. Tim Squier 487 Deerfield Dakota Dunes, SD 57049 Re: Project #: 4004-040 487 Deerfield, Dakota Dunes SD Microbial Clearance Testing INTRODUCTION: This report presents the findings

More information

MOLD SCREENING REPORT

MOLD SCREENING REPORT MOLD SCREENING REPORT Mount Washington Middle School 269 Water Street Mt. Washington, KY 40047 Project # 115-7346 BCBOE PO#156081 Prepared for: Mr. Mark Mitchell Director, Buildings and Grounds Bullitt

More information

DATE: October 21, TO: Susan Blockley, Director

DATE: October 21, TO: Susan Blockley, Director DATE: October 21, 2013 TO: Susan Blockley, Director SUBJECT: Campus Support Services-Charles Street - IAQ - Air Test - Storage Rm- Southwest Corner Rm, Martha Fahlund's Office, Storage Rm-Northwest Corner

More information

February 8, Post-Remediation Fungal Assessment Blackhawk Intermediate School 603 Shenango Road Beaver Falls, PA PSI Project No.

February 8, Post-Remediation Fungal Assessment Blackhawk Intermediate School 603 Shenango Road Beaver Falls, PA PSI Project No. February 8, 2018 Blackhawk School District 500 Blackhawk Road Beaver Falls, PA 15010-1498 Attention: Dr. Robert Postupac, Superintendent postupacr@bsd.k12.pa.us Re: Post-Remediation Fungal Assessment Blackhawk

More information

INTRODUCTION. The evaluation was performed in the morning and afternoon on a weekday during normal building operations.

INTRODUCTION. The evaluation was performed in the morning and afternoon on a weekday during normal building operations. INTRODUCTION A preliminary indoor air quality (IAQ) evaluation was performed at the City of Stockton Police Department on March 23, 20. John J. Sacco, P.E., CIH of Earthshine Consulting, Inc (ECI) performed

More information

ANALYTICAL REPORT. Airconstruct HVAC Pty Ltd 37 Carlyle Street Mackay QLD Withheld PROPERTY:

ANALYTICAL REPORT. Airconstruct HVAC Pty Ltd 37 Carlyle Street Mackay QLD Withheld PROPERTY: NSJ EnviroSciences Pty Ltd t/a MouldLab ABN 27 143 789 995 PO Box 306 WICKHAM NSW 2293 Phone: 02 4968 8448 Fax: 02 8004 3576 Mobile: 0410 239 848 Email: ---------------------------- ANALYTICAL REPORT CLIENT:

More information

Via . September 5, City of Charlotte Engineering & Property Management 600 E. 4 th Street, 12 th Floor Charlotte, NC

Via  . September 5, City of Charlotte Engineering & Property Management 600 E. 4 th Street, 12 th Floor Charlotte, NC Via Email September 5, 2014 City of Charlotte Engineering & Property Management 600 E. 4 th Street, 12 th Floor Charlotte, NC 28204-2844 Attention: Mr. David Wolfe, PE Re: Moisture Screening and Mold Air

More information

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR:

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR: SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD 21738 PREPARED FOR: HOWARD COUNTY PUBLIC SCHOOL SYSTEM 10910 ROUTE 108 ELLICOTT CITY, MD 21043 PREPARED BY: ARIA ENVIRONMENTAL,

More information

MOLD SCREENING REPORT

MOLD SCREENING REPORT MOLD SCREENING REPORT Mount Washington Middle School 269 Water Street Mt. Washington, KY 40047 Project # 115-7358 Prepared for: Mr. Mark Mitchell Director, Buildings and Grounds Bullitt County Board of

More information

DATE: October 31, TO: Toby Maxson, Principal. SUBJECT: Heritage ES - IAQ - Initial Contact - Room B-16

DATE: October 31, TO: Toby Maxson, Principal. SUBJECT: Heritage ES - IAQ - Initial Contact - Room B-16 DATE: October 31, 2016 TO: Toby Maxson, Principal SUBJECT: Heritage ES - IAQ - Initial Contact - Room B-16 On Friday 10/28, I received Work Order #344295: Principal would like room tested: Per teacher

More information

Dalrymple Consulting, Inc. "Your Environmental Engineering Source" 7841 SW 1 i b Street, Topeka, Kansas (785) FAX (785)

Dalrymple Consulting, Inc. Your Environmental Engineering Source 7841 SW 1 i b Street, Topeka, Kansas (785) FAX (785) Dalrymple Consulting, Inc. "Your Environmental Engineering Source" 7841 SW 1 i b Street, Topeka, Kansas 66615-1406 (785) 273-0345 FAX (785) 273-3071 January 10,2012 Mr. Steve Wiseman, Superintendent Atchison

More information

DATE: March 23, TO: Chad Russell, Principal. SUBJECT: Lamar MS - IAQ - Air Test Results - Main Gym

DATE: March 23, TO: Chad Russell, Principal. SUBJECT: Lamar MS - IAQ - Air Test Results - Main Gym DATE: March 23, 2018 TO: Chad Russell, Principal SUBJECT: Lamar MS - IAQ - Air Test Results - Main Gym On Monday 3/19, Apex-Titan Air tested the Main Gym. It is typically assumed that indoor spore levels

More information

UNIVERSAL HOME & MOLD INSPECTIONS Where Quality and Details Count!

UNIVERSAL HOME & MOLD INSPECTIONS Where Quality and Details Count! Project # PRV140519 UNIVERSAL HOME & MOLD INSPECTIONS Where Quality and Details Count! Post Remediation Verification Visual Post-Remediation Verification With Non-viable Mold Sampling Client: Lauren Gash

More information

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. BB Owen Elementary School Library 5640 Squires The Colony, Texas

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. BB Owen Elementary School Library 5640 Squires The Colony, Texas POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT BB Owen Elementary School Library 5640 Squires The Colony, Texas May 20, 2013 Project No. 0113H113 Prepared for: Lewisville Independent School District

More information

Mr. Jody Davis PO Box 1475 Montgomery, TX

Mr. Jody Davis PO Box 1475 Montgomery, TX Texas Association of School Boards P.O. Box 400 Austin, TX 78767-0400 512-467-0222 Serving Texas School Boards since 1949 January 7, 2014 Mr. Jody Davis PO Box 1475 Montgomery, TX 77356-1475 Dear Mr. Davis:

More information

The attached report is the result of a mold and bacterial assessment conducted at th Street, Franklin, Ohio on April 24 and 25, 2008.

The attached report is the result of a mold and bacterial assessment conducted at th Street, Franklin, Ohio on April 24 and 25, 2008. May 8, 2008 Jon Lampros President Clean Air Systems 701 Rockland Rd. Lake Bluff, IL 60044 Re: Assessment of Ozone Treatment on Microbial Populations Dear Mr. Lampros, The attached report is the result

More information

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. Marcus High School ROTC Hallway 5707 Morriss Road Flower Mound, Texas

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. Marcus High School ROTC Hallway 5707 Morriss Road Flower Mound, Texas POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT Marcus High School ROTC Hallway 5707 Morriss Road Flower Mound, Texas August 17, 2015 LISD PO No. 91538989-00 Apex Project No. 7250115212 Prepared

More information

Limited Indoor Air Quality Assessment

Limited Indoor Air Quality Assessment Young Rainey STAR Center Areas 121 and 133 7887 Bryan Dairy Road Largo, Florida March 3, 2014 Terracon Project No. H4147022 Prepared for: Young Rainey STAR Center Pinellas County BOCC 7887 Bryan Dairy

More information

Limited Mold Sampling Investigation Report

Limited Mold Sampling Investigation Report Page 1 of 13 Limited Mold Sampling Investigation Report 9811 W. Charleston Blvd Suite 2403 Las Vegas, NV 89117 Tel: 702.255.2457 * Fax: 702.953.0286 www.msenational.com * info@msenational.com Customer

More information

Post Remediation Verification For 845 W. Center Street Pocatello, Idaho

Post Remediation Verification For 845 W. Center Street Pocatello, Idaho Post Remediation Verification For 845 W. Center Street Pocatello, Idaho Prepared for: Bank of the Cascades 1070 NW Bond Street, Suite 212 Bend, Oregon 97701 Prepared By: Summit 795 S. Orchard Street Boise,

More information

Mould Investigation. Loretto Abbey Catholic Secondary School 101 Mason Boulevard North York, Ontario

Mould Investigation. Loretto Abbey Catholic Secondary School 101 Mason Boulevard North York, Ontario Mould Investigation Loretto Abbey Catholic Secondary School 101 Mason Boulevard North York, Ontario Prepared for: Toronto Catholic District School Board Prepared by: Stantec Consulting Ltd. 2100 Derry

More information

Table 1: Fungal Particulate Air Sample Results. ST-32 Room 17; post clean-up 5. 2 nd floor; commons area adjacent to Room 617

Table 1: Fungal Particulate Air Sample Results. ST-32 Room 17; post clean-up 5. 2 nd floor; commons area adjacent to Room 617 November 29, 2016 Chuck Doan Yakima School District #7 104 N 4th Avenue Yakima, WA 98902 Via email: Regarding: doan.chuck@yakimaschools.org Fungal Sample Results Blue Wall Room 617 Eisenhower High School

More information

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE)

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE) Expert Services in Environmental Microbiology Report Supporting Document ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION (Analysis Code: FDE) INTRODUCTION Fungi are

More information

SPORE TRAP SAMPLING REPORT FOR CENTENNIAL LANE ELEMENTARY SCHOOL 3825 CENTENNIAL LANE ELLICOTT CITY, MARYLAND PREPARED FOR:

SPORE TRAP SAMPLING REPORT FOR CENTENNIAL LANE ELEMENTARY SCHOOL 3825 CENTENNIAL LANE ELLICOTT CITY, MARYLAND PREPARED FOR: SPORE TRAP SAMPLING REPORT FOR CENTENNIAL LANE ELEMENTARY SCHOOL 3825 CENTENNIAL LANE ELLICOTT CITY, MARYLAND 21042 PREPARED FOR: HOWARD COUNTY PUBLIC SCHOOL SYSTEM 10910 ROUTE 108 ELLICOTT CITY, MD 21043

More information

October 14, Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona PO#

October 14, Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona PO# Asbestos Testing Lead Testing Microbial Testing Management Analysis Environmental Assessment October 14, 2014 Attn: Deer Valley Unified School District Jim Migliorino 20402 North 15th Avenue Phoenix, Arizona

More information

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD Regulatory Compliance 245 Albany Avenue Thornwood, New York 10594 (914) 439-6513 Indoor Air Quality Screening At Scarsdale UFSD High School 1057 East Post Road Scarsdale, NY 10583 Rooms 394 RegCom s Project

More information

November 18, Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona PO#

November 18, Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona PO# Asbestos Testing Lead Testing Microbial Testing Management Analysis Environmental Assessment November 18, 2014 Attn: Deer Valley Unified School District Jim Migliorino 20402 North 15th Avenue Phoenix,

More information

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR:

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR: SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD 21738 PREPARED FOR: HOWARD COUNTY PUBLIC SCHOOL SYSTEM 10910 ROUTE 108 ELLICOTT CITY, MD 21043 PREPARED BY: ARIA ENVIRONMENTAL,

More information

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. Bolin Administrative Center Suite W. Main Street Lewisville, Texas

POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT. Bolin Administrative Center Suite W. Main Street Lewisville, Texas POST-REMEDIATION MOLD ASSESSMENT AND CLEARANCE REPORT Bolin Administrative Center Suite 105 1585 W. Main Street Lewisville, Texas May 30, 2017 Apex Project No. 72501027079 Prepared for: Lewisville Independent

More information

RESIDENTIAL MOLD ASSESSMENT. Final Report. Your Address Here

RESIDENTIAL MOLD ASSESSMENT. Final Report. Your Address Here 2847 Barnard Street San Diego California 92110 Phone 619.501.0185 Mobile 619.203.9774 Fax 619.501.9843 hoveyenv@cox.net RESIDENTIAL MOLD ASSESSMENT Final Report Your Address Here September 1, 2003 Prepared

More information

Health & Public Safety Management

Health & Public Safety Management . Health & Public Safety Management Indoor Air Quality Investigation White Hall Building Assessment Period March 24 9th, 2004 Phase II Prepared 5/5/2004 By Luigi Marcone Director of Health and Public Safety

More information

Sampling for Mould in Red Bluff Elementary School, Quesnel

Sampling for Mould in Red Bluff Elementary School, Quesnel Sampling for Mould in Red Bluff Elementary School, Quesnel Introduction What are moulds? Moulds are part of the fungi kingdom and serve an important role in breaking down organic matter. They are found

More information

Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy

Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy The University of British Columbia Land and Building Services MOULD PROCEDURE Work Procedure I-B-46 Prepared by: LBS HSE Approved by: Geoff Atkins Issue Date: New Policy Replaces: 1.0 APPLICATION Moulds

More information

Basic Industrial Hygiene Sampling Overview of Indoor Air Quality

Basic Industrial Hygiene Sampling Overview of Indoor Air Quality Basic Industrial Hygiene Sampling Overview of Indoor Air Quality Bryan K. Stolte, Ph.D., C.I.H. Alcatel-Lucent Corporate EHS Office International Telecommunication Safety Conference Denver, CO Sept 14

More information

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR:

SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD PREPARED FOR: SPORE SAMPLING REPORT FOR GLENWOOD MIDDLE SCHOOL 2680 ROUTE 97 GLENWOOD, MD 21738 PREPARED FOR: HOWARD COUNTY PUBLIC SCHOOL SYSTEM 10910 ROUTE 108 ELLICOTT CITY, MD 21043 PREPARED BY: ARIA ENVIRONMENTAL,

More information

Limited Indoor Air Quality Assessment

Limited Indoor Air Quality Assessment Limited Indoor Quality Assessment Salinas Elementary School 000 Century Drive West Laredo, Webb County, Texas September 5, 20 Terracon Project No. 9045-R Prepared for: United Independent School District

More information

Re: Elizabeth Middle School at County Road 13 in Elizabeth, CO Limited Ambient Microflora Inspection & Sampling

Re: Elizabeth Middle School at County Road 13 in Elizabeth, CO Limited Ambient Microflora Inspection & Sampling November 19, 2012 Mr. Ron Patera Elizabeth School District 633 Dale Court Elizabeth, CO 80107 Re: Elizabeth Middle School at 34427 County Road 13 in Elizabeth, CO 80107 Limited Ambient Microflora Inspection

More information

BIO-REMEDIATION ASSESSMENT

BIO-REMEDIATION ASSESSMENT Air Quality Management Services, Inc. Discovering Solutions for Healthier Living BIO-REMEDIATION ASSESSMENT Manchester Elementary School 17 School Street Manchester, Maine PREPARED FOR RSU #38 C/o Curt

More information

Indoor Air Quality Report

Indoor Air Quality Report Indoor Air Quality Report Shawnee City Hall 222 N. Broadway, Shawnee, Oklahoma 74801 INDOOR AIR QUALITY SAMPLING REPORT Project Locations: Shawnee City Hall 222 N. Broadway, Shawnee, Oklahoma 74801 Prepared

More information

INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS

INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS T Nathanson* Public Works and Government Services Canada, Ottawa, Canada ABSTRACT The potential for microbial contamination exists in every building and

More information

FILED: NEW YORK COUNTY CLERK 07/14/ :42 PM INDEX NO /2016 NYSCEF DOC. NO. 25 RECEIVED NYSCEF: 07/14/2016

FILED: NEW YORK COUNTY CLERK 07/14/ :42 PM INDEX NO /2016 NYSCEF DOC. NO. 25 RECEIVED NYSCEF: 07/14/2016 FILED: NEW YORK COUNTY CLERK 07/14/2016 01:42 PM INDEX NO. 154125/2016 NYSCEF DOC. NO. 25 RECEIVED NYSCEF: 07/14/2016 Project: Post-Mold Remediation Verification Survey Location: 1045 Park Avenue Apt.

More information

September 18, 204. Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona 85383

September 18, 204. Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona 85383 Asbestos Testing Lead Testing Microbial Testing Management Analysis Environmental Assessment September 18, 204 Attn: Valley Schools Insurance Trust and Pools Scott McCleary PO Box 41760 Phoenix, Arizona

More information

Maintaining Safe Indoor Air Quality in State Occupied Buildings

Maintaining Safe Indoor Air Quality in State Occupied Buildings Maintaining Safe Indoor Air Quality in State Occupied Buildings Indoor Air Quality Facts and Figures People spend an estimated 90% of their time indoors. Environmental Protection Agency (EPA) studies have

More information

p:\0816\2016\iaq\general\ hampton\ wyland\ wyland iaq report.doc Enclosures

p:\0816\2016\iaq\general\ hampton\ wyland\ wyland iaq report.doc Enclosures October 27, 2016 Hampton School District 4591 School Drive Allison Park, PA 15101 Attn: Mr. Rick Farino Facilities Manager Re: Indoor Air Quality & Odor Investigation Wyland Elementary School Lower Level

More information

May 1 st, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7

May 1 st, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 May 1 st, 2018 University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 Attn: Mr. Irfan Miraj, P.Eng., MHSc. Manager, Hazardous Construction Materials Group Re: Results of PCM and TEM

More information

September 11, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7

September 11, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 September 11, 2017 University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 Attn: Mr. Irfan Miraj, P.Eng., MHSc. Manager, Hazardous Construction Materials Group Re: Results of PCM and

More information

February 21, Mold Assessment. 400 East Avenue, Warwick, Rhode Island. Dear Mr. McCabe:

February 21, Mold Assessment. 400 East Avenue, Warwick, Rhode Island. Dear Mr. McCabe: February 21, 2014 Mr. Ken McCabe Lincoln Campus Physical Plant Director Community College of Rhode Island Knight Campus 400 East Avenue Warwick, Rhode Island 02866 Re: Mold Assessment Community College

More information

All questions regarding the attached study should be directed to the Howard County Government s public information office at

All questions regarding the attached study should be directed to the Howard County Government s public information office at All questions regarding the attached study should be directed to the Howard County Government s public information office at 410-313-2022. 449 Eisenhower Boulevard, Suite 300 Harrisburg, PA 17111-2302

More information

NCCEH Mould Investigation Toolkit

NCCEH Mould Investigation Toolkit NCCEH Mould Investigation Toolkit Interpretation of Microbial Laboratory Reports NOVEMBER 2014 Table of Contents Introduction... 2 Generic Information All Microbial Laboratory Reports... 3 Direct Examination

More information

TYPE 3 ASBESTOS ABATEMENT UNIVERSITY OF WINDSOR BIOLOGY BUILDING LABS 204 & 206 WINDSOR, ONTARIO. Issued: March 15 th, 2010

TYPE 3 ASBESTOS ABATEMENT UNIVERSITY OF WINDSOR BIOLOGY BUILDING LABS 204 & 206 WINDSOR, ONTARIO. Issued: March 15 th, 2010 Environmental Consultants 931 Commissioners Rd East, Suite 100 London, Ontario N5Z 3H9 Tel: (519) 685-9048 Fax: (519) 685-1042 TYPE 3 ASBESTOS ABATEMENT UNIVERSITY OF WINDSOR BIOLOGY BUILDING LABS 204

More information

March 29 th, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7

March 29 th, University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 March 29 th, 2017 University of Toronto 255 McCaul Street, Level 4 Toronto, Ontario M5T 1W7 Attn: Mr. Irfan Miraj, P.Eng., MHSc. Manager, Hazardous Construction Materials Group Re: Results of PCM and TEM

More information

Background Air Sampling Auburn Village School, New Modular Classrooms SLGL File Number

Background Air Sampling Auburn Village School, New Modular Classrooms SLGL File Number March 20, 2014 Mr. Peter Barbuto, Director of Maintenance School Administrative Unit No. 15 Hooksett School District 90 Farmer Road Hooksett, New Hampshire 03106 Re: Background Air Sampling Auburn Village

More information

MARTIN AND WILLIAMSON HALL BUILDINGs Eastern Washington University, Cheney, Washington INDOOR AIR QUALITY SAMPLING PLAN

MARTIN AND WILLIAMSON HALL BUILDINGs Eastern Washington University, Cheney, Washington INDOOR AIR QUALITY SAMPLING PLAN MARTIN AND WILLIAMSON HALL BUILDINGs Eastern Washington University, Cheney, Washington INDOOR AIR QUALITY SAMPLING PLAN Prepared for Eastern Washington University Facilities and Planning Department 101

More information

BIOAIRE CASSETTE Impaction Particle Sampler

BIOAIRE CASSETTE Impaction Particle Sampler USER MANUAL FOR BIOAIRE CASSETTE Impaction Particle Sampler A.P. Buck, Inc. 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 12 bioaire@apbuck.com

More information

April 21, Dear Mike,

April 21, Dear Mike, AECOM 1555 North RiverCenter Drive Suite 214 Milwaukee, Wisconsin 53212 414.944.6080 tel 414.944.6081 fax April 21, 2015 Mr. Michael Lewis, P.E. City of West Allis Department of Public Works/City Engineer

More information

Table of Contents. C. Recommended Remediation Firms: upon request

Table of Contents. C. Recommended Remediation Firms: upon request Table of Contents I. Job, Contact & Site Information II. Scope of Work III. Building Overview IV. Findings V. Conclusions and Recommendations VI. Expectations VII. References VIII. Limits of Liability

More information

Project 6668 Second beach Concession-Stanley Park Drive,Vancouver, BC Division 02080

Project 6668 Second beach Concession-Stanley Park Drive,Vancouver, BC Division 02080 PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the City of Vancouver Invitation to Tender including all available documents,

More information

To help protect your privacy, PowerPoint has blocked automatic download of this picture. Long Term Care Building Conference NOVEMBER 29,2013

To help protect your privacy, PowerPoint has blocked automatic download of this picture. Long Term Care Building Conference NOVEMBER 29,2013 To help protect your privacy, PowerPoint has blocked automatic download of this picture. Long Term Care Building Conference NOVEMBER 29,2013 PRESENTERS Wanda Mitton - Technical Sales for 27 years - Sales

More information

QuES&T. Microbial Investigation and Moisture Assessment. Final Project Report. Prepared for. Croton Harmon Union Free School District

QuES&T. Microbial Investigation and Moisture Assessment. Final Project Report. Prepared for. Croton Harmon Union Free School District QuES&T Quality Environmental Solutions & Technologies, Inc. Microbial Investigation and Moisture Assessment Final Project Report Prepared for Croton Harmon Union Free School District At Carrie E. Tompkins

More information

Project 6668 Kerrisdale Senoirs Centre-5851 West Boulevard,Vancouver, BC Division 02080

Project 6668 Kerrisdale Senoirs Centre-5851 West Boulevard,Vancouver, BC Division 02080 PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the Invitation to Tender including all available documents, meeting minutes,

More information

MOLD REMEDIATION PROCEDURES AT A NEW JERSEY ELEMENTARY SCHOOL

MOLD REMEDIATION PROCEDURES AT A NEW JERSEY ELEMENTARY SCHOOL MOLD REMEDIATION PROCEDURES AT A NEW JERSEY ELEMENTARY SCHOOL M McGuinness * R.K. Occupational and Environmental Analysis, Phillipsburg, NJ, USA ABSTRACT Microbiological remediation procedures at an Elementary

More information

HVAC. Hygiene. abstract. Mr Jeremy Stamkos

HVAC. Hygiene. abstract. Mr Jeremy Stamkos NADCA Mr Jeremy Stamkos Managing Director, Enviroair Pty Ltd Certified Air Systems Cleaning Specialist abstract This article has been written to assist those responsible for the maintenance and operation

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Evaluation of Risk of Mold Damages Based on a Novel Dust Sampling Method

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Evaluation of Risk of Mold Damages Based on a Novel Dust Sampling Method Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0279 ISBN: 978-83-7947-232-1 Evaluation of Risk of Mold Damages Based on a Novel Dust Sampling Method Mari Sand Austigard 1, Ingeborg

More information

LIMITED MOLD ASSESSMENT REPORT

LIMITED MOLD ASSESSMENT REPORT LIMITED MOLD ASSESSMENT REPORT City of Panama City New City Hall 501 Harrison Avenue Panama City, Florida 32401 PREPARED FOR: City of Panama City, Florida 9 Harrison Avenue Panama City, Florida 32402 NOVA

More information

Powers Environmental LLC

Powers Environmental LLC Powers Environmental LLC POST-REMEDIATION VERIFICATION CLEARANCE REPORT GENERAL INFORMATION Report Date: 09/06/2017 Assessment Date: 09/05/2017 Project Number: 2017222 Time: 7:00 AM Ground Condition: Dry

More information

ASBESTOS SCIENCE TECHNOLOGIES, INC.

ASBESTOS SCIENCE TECHNOLOGIES, INC. ASBESTOS SCIENCE TECHNOLOGIES, INC. P.O. Box 505 Bangor, CA 95914 Phone (530) 518-0934 Email - astinc17@yahoo.com Report for Trinity Valley Elem. School Willow Creek, Ca. Mold Report - Rooms 12 through

More information

DryScan Limited was engaged to complete a Pre-Purchase Scan only moisture ingress thermal imaging inspection for Joe Blogs at 8 Anywhere, Auckland.

DryScan Limited was engaged to complete a Pre-Purchase Scan only moisture ingress thermal imaging inspection for Joe Blogs at 8 Anywhere, Auckland. Infrared Inspections DryScan Limited PO Box 869, Whangaparoa, Auckland 0943 Free phone: 0800-DRYSCAN ~ Mobile: 021 892 056 ~ Fax: 0064 9 421 1792 Email: bryce@dryscan.co.nz 6 th March 2012 Joe Blogs 8

More information

Healthy Home Package: Asbestos & Mould Sampling Report

Healthy Home Package: Asbestos & Mould Sampling Report Healthy Home Package: Asbestos & Mould Sampling Report Client s Address Toronto, ON Postal Code Prepared for: Client s Name Prepared by: Lilja Palsson, B.Sc., Dip. Eng., CRSP Project Number: #### LEAP

More information

SUMMARY OF OUR FINDINGS

SUMMARY OF OUR FINDINGS May 11, 2009 Mr. S. H. PO Box XXX Woodmere, NY 11598 Dear Mr. H., SUMMARY OF OUR FINDINGS A site visit was conducted on Tuesday, May 5 th 2009 at the above inspection address. A visual investigation of

More information

A L A R A Environmental Health & Safety Ltd.

A L A R A Environmental Health & Safety Ltd. Metro Home Inspections October 4, 2010 7626 Arvin Court Burnaby, BC V5A 4M9 ATTENTION: Mr. Mark Fagrie RE: Indoor Air Quality Investigation at Little Mountain Housing, 159 Grouse Walk, Vancouver, BC Dear

More information

AIVC #12,964 ABSTRACT INTRODUCTION THE PACT OF H.V.A.C. SYSTEM CLEANING ON LEVELS OF SURFACE DUST AND VIABLE FUNGI IN DUCTWORK

AIVC #12,964 ABSTRACT INTRODUCTION THE PACT OF H.V.A.C. SYSTEM CLEANING ON LEVELS OF SURFACE DUST AND VIABLE FUNGI IN DUCTWORK . -,., _,.. - ---......,..----- -- - ------- AIVC #,96 THE PACT OF H.V.A.C. SYSTEM CLEANING ON LEVELS OF SURFACE DUST AND VIABLE FUNGI IN DUCTWORK CW Collett\ T Nathanson, J A Scott', K Baer and J Waddington6

More information

Appendix D Location Specific Technical Reports

Appendix D Location Specific Technical Reports Appendix D Location Specific Technical Reports SEL Project Number 119917 March 29, 2017 Air Sampling Program University of Toronto Medical Sciences Building 1 King s College Circle, Toronto, Ontario Page

More information

FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL. Prepared for:

FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL. Prepared for: FOLLOW-UP TOTAL VOLATILE ORGANIC COMPOUND SAMPLING SIR WILFRED GRENFELL COLLEGE CORNER BROOK, NL Prepared for: SIR WILFRED GRENFELL COLLEGE 1 UNIVERSITY DRIVE CORNER BROOK, NL A2H 6P9 ATTENTION: MR. DAVID

More information

REPORT. Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage CITY OF SASKATOON.

REPORT. Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage CITY OF SASKATOON. CITY OF SASKATOON Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage REPORT Submitted to: The City of Saskatoon 1101 Avenue P North Saskatoon, SK S7L 7K6 Report

More information