1 Substation Developments Environmental Guidelines Checklist for Applicants Effective date: February 1, 2016 These guidelines are intended to be used in conjunction with the flowchart in Figure 1 which conceptually illustrates procedural steps to be considered by applicants for new substation construction and for existing substation modifications. Each question is to be answered with: yes, no, not applicable (N/A), or explain accordingly. Development of new substations The following sections apply only if the project involves the development of a new substation. General: 1) Have you described the existing (i.e. pre-construction) environmental and land-use conditions on the substation site and in the local study area? 2) Does your project incorporate the guidelines contained in Alberta Environment and Parks (AEP) Environmental Protection Guidelines for Transmission Lines (R&R/11-03) document, and if not, have you described what aspects of the project do not incorporate the guidelines? 3) Have you described the potential adverse effects of the substation on the environment, including, as applicable, terrain and soils, surface water bodies and hydrology, groundwater, wetlands, vegetation species and communities, wildlife species and habitat, aquatic species and habitat, air quality, environmentally sensitive areas and land use? 4) Have you described the approach to manage stormwater runoff on the substation site to protect on-site and off-site terrain, soils, surface water quality, groundwater, and land use? 5) Have you submitted a project-specific environmental protection plan or otherwise itemized and described the mitigation measures and monitoring activities that you will implement during construction and operation to minimize any adverse effects of the substation on the environment? 6) Have you identified the government agencies or departments that you consulted with as part of your site selection phase, described any prescribed guidelines and stated in the application how the guidelines will be followed?

2 Substation Developments Environmental Guidelines Effective date: February 1, 2016 Checklist for Applicants Page 2 of 6 Land use: 7) If the substation is being developed on Crown lands, have you consulted with the regional approvals program area of AEP on the project, regarding siting and the potential disturbance by the project of land with protective notations on the land title and any other surface activity dispositions and described any specific mitigation measures that you will incorporate into the project as a result of that consultation? 8) Have you determined if the proposed development is compatible with any area restrictions and ensured the project is not in an area where development of new transmission facilities is prohibited under federal or provincial authority such as the Wilderness Areas, Ecological Reserves and Natural Areas Act, Provincial Parks Act or Willmore Wilderness Park Act? 9) If the substation site occurs on or is bordered by agricultural land, have you developed procedures and consulted with the landowners and appropriate local municipalities with respect to rules and procedures on preventing the spread of weeds and pests 1 on agricultural land? 10) If the substation site is located on land where soils or vegetation have not been previously disturbed, did you obtain Historical Resources Act approval from Alberta Culture and Tourism for the project? Wildlife and aquatic species: 11) If the substation is proposed within or adjacent to a wetland or potential fish and wildlife habitat: (a) Have you described consultation with AEP in regard to any Water Act or Wildlife Act related aspects of the proposed substation, described any AEP prescribed guidelines and stated how the guidelines will be followed? (b) Have you described the results of a self-assessment under Department of Fisheries and Oceans Canada (DFO) guidelines or, if necessary, have you described the results of a DFO review of the project? (c) Have you described any outstanding wildlife, vegetation, or aquatic issues identified by AEP or DFO biologists regarding the proposed development, which have not yet been fully addressed? 12) Have you described any mitigation measures you will implement during operation of the substation to minimize the electrocution of birds and animals by substation equipment? 1 Pests are defined in the Alberta Agricultural Pests Act RSA 2000, Chapter A-8.

3 Substation Developments Environmental Guidelines Effective date: February 1, 2016 Checklist for Applicants Page 3 of 6 Substation modifications The following sections apply to the non-emergency salvage, modification or repair of existing substations where soil excavation or disturbance, on or immediately adjacent to a substation site, is proposed. Basic substation information: 1) Have you provided the substation name with a unique identification number? 2) Have you provided the legal land description, as well as the latitude and longitude or municipal address of the substation? 3) Have you indicated the date the substation commenced operations? 4) Have you described the existing environmental and land-use conditions on the substation site and in the local study area? 5) Have you described the potential adverse effects of the substation modification on the environment, including as applicable, terrain and soils, surface water bodies and hydrology, groundwater, wetlands, vegetation species and communities, wildlife species and habitat, aquatic species and habitat, air quality, environmentally sensitive areas and land use? 6) Have you described how any potential environmental effects of the project will be mitigated? Operational history to determine the detail and type of information needed: 7) Was any electrical equipment containing insulating oil installed with underlying secondary containment on the existing substation site? If yes ensure you complete line 12 Adequacy Of Secondary Containment. 8) Have you described the duration of any polychlorinated biphenyls (PCB) use on-site and indicated both the maximum and the current PCB content of all fluid-filled electrical equipment that is not hermetically sealed? 9) Was a secondary containment system installed after the substation commenced operations? If yes ensure you complete line 11 Substations Operated for a Time Without Secondary Containment.

4 Substation Developments Environmental Guidelines Effective date: February 1, 2016 Checklist for Applicants Page 4 of 6 Environmental evaluation: 10) For substations currently operating without underlying secondary containment, or in cases where the history of the secondary containment is unknown, have you: (a) Completed the steps in Figure 1 Process Flowchart for New Substations and Existing Substation Modifications and provided the date that the environmental evaluation was completed? (b) Described the methodology and summarized the conclusions of the environmental evaluation conducted to assess the likelihood of encountering contamination and any need for further assessment? (c) Complied with Alberta release reporting requirements (if needed)? 2 (d) Described any additional contaminant assessment or remediation proposed during the proposed work (if needed)? (e) Described any soil sampling or further environmental evaluation to be undertaken during the proposed work? (f) Briefly described plans to safely manage, transport and dispose of any used insulating oil during the proposed work? (g) Briefly described plans to assess and, if needed, transport and dispose of soil affected by releases of regulated fluids? (h) Described any public health and safety measures to protect the public from environmental hazards during the proposed work? (i) Described how contaminated or potentially contaminated soil and groundwater is being managed to prevent the migration of contaminants off the substation site? 2 The Environmental Protection and Enhancement Act RSA 2000 Chapter E-12 requires any release of substances that may cause, is causing or has caused an adverse effect to the environment to be reported to Alberta Environment and Parks. An adverse effect is impairment of, or damage to, the environment, human health or safety, or property. The Release Reporting Regulation sets out what must be reported, when, how and to whom reports must be made. Table 1 of Alberta Tier 1 Soil and Groundwater Remediation Guidelines contains maximum contaminant levels for various compounds. Individual approvals and codes of practice may also have requirements for reporting contraventions of the terms and conditions of the approval or code of practice, monitoring results and sampling programs.

5 Substation Developments Environmental Guidelines Effective date: February 1, 2016 Checklist for Applicants Page 5 of 6 Substations operated for a time without secondary containment: 11) For substations where secondary containment was installed after the electrical equipment commenced operations, have you: (a) Indicated the date secondary containment was installed? (b) Briefly described the nature of the secondary containment and its installation? (c) Described any soils assessment conducted prior to installation of the secondary containment? i. If yes, have you summarized the conclusions and recommendations of the soils assessment report and described any contaminant risk management or further environmental evaluation proposed during the proposed work? ii. If no, have you described how the potential for contaminants under the secondary containment was assessed and how any associated contaminant risks are being managed? Adequacy of secondary containment: 12) For substations where secondary containment is now in place have you: (a) (b) (c) (d) (e) (f) (g) Listed the electrical equipment under which secondary containment was installed? Indicated if the integrity of the secondary containment(s) has been tested in accordance with applicable standards and/or electrical industry best management practices and briefly described the test results? Indicated the date of any environmental field inspection conducted and summarized the conclusions and recommendations? Briefly described plans to safely manage, transport and dispose of any used insulating oil during the proposed work? If planning to excavate within the secondary containment, have you briefly described plans to assess and, if needed, transport and dispose of backfill material affected by releases of regulated fluids? Described any public health and safety measures to protect the public from environmental hazards during the proposed work? Described how contaminated or potentially contaminated soil and groundwater is being managed to prevent the migration of contaminants off the substation site?

6 Substation Developments Environmental Guidelines Effective date: February 1, 2016 Checklist for Applicants Page 6 of 6 Figure 1 - New substation construction or existing substation modification flow chart (return to text) Flow_Chart_ docx (consists of 4 pages)

7 Environmental guidelines for new substation construction or existing substation modification flow chart Prepare scope of work for equipment change or addition of substation Describe project components and activities Describe other approvals. (e.g. Historical Resources Act, Water Act, or Public Land Act clearances...etc.) Determine project type New substation (go to page 2) Equipment change using existing infrastructure; no soil excavation (go to page 3) Existing substation soil excavation required to change equipment or expand disturbed area (go to page 4) Page 1 of 4

8 New substation New or expanded disturbed area Environmental assessment As appropriate for the existing land-use assess current conditions and predict effects to: vegetation wildlife and wildlife habitat soil and terrain hydrology and wetlands water quality existing land use other Assess to AEP guidelines/criteria and other legislation where applicable Consult with AEP and Alberta Culture and Tourism when applicable Describe environmental effects and any mitigation, EPP. Submit application to the AUC AUC permit and licence received Secure approvals from other applicable regulatory agencies Implement mitigation measures and conduct environmental monitoring during construction and operation Document and retain on file Page 2 of 4

9 Equipment change using existing infrastructure; no soil excavation Describe basic environmental protection measures Submit application to the AUC AUC permit and licence received Page 3 of 4

10 Existing substation Soil excavation required to change equipment or expand disturbed area There is no electrical equipment with the local study area that contains nonhermetically sealed insulating fluids Liner under fluidfilled equipment when constructed Electrical equipment within the local study area contains insulating fluids that are not hermetically sealed Liner installed under fluid-filled equipment after construction No liner under fluidfilled equipment or no assessment of residual contamination when liner installed Contamination assessment Review site history to evaluate potential contamination: Biophysical components (based on existing land use) Hydrology and surface water quality Review site information O & M record Incident spill records PCB records Existing environmental reports Complete a site visit (under snow free condition) Document soil staining or other deficiencies Other Describe environmental effects and any mitigation, EPP. Submit application to AUC Describe how the integrity of the liner is monitored. Describe results of monitoring to date. Characterize risk of residual contamination based on assessment at time of liner installation. Describe action regarding any site-specific risk management. No Incorporate AEP guidelines and consult with AEP if required Contamination found If file record is incomplete explain and propose sampling of excavated area Review results of contaminant assessment in relation to regulatory requirements AUC permit and license received If reportable release (see footnote 1 below): Notify AEP and implement mitigation as required If non-reportable: Document and retain on file and describe plans to address deficiencies in future modification work or ongoing operation and maintenance Yes Potential contamination outside of area proposed for excavation Potential contamination within area proposed for excavation AUC permit and license received Submit application to the AUC Not expanding disturbed area Include a contaminated soil management procedure (sitespecific) and/or EPP If reportable release (see footnote 1 below): Notify AEP and implement mitigation as required If non-reportable: Document any deficiencies, leaks, and soil staining within the scope of work, and describe how addressed in application Substation decommissioning/ abandonment and reclamation Environmental monitoring during decommissioning Remove equipment Phase II ESA or equivalent Delineate and excavate Sample walls and base of excavation (closure sampling) Dispose recovered soils at an approved facility Clean up to reclamation criteria Prepare site for reclamation certification Monitor Complete a detailed site assessment Apply to AEP for reclamation certification Upgrade/repair/replacement/salvage (within scope of proposed work) Environmental monitoring during construction If contaminated soil found in planned ground disturbance area, excavate and recover soil to the sagest and most practical extent possible Sample walls and base of excavation (closure sampling) If residual contamination implement site-specific contaminant risk management plan. Dispose recovered soils at an approved facility If unsafe to clean up (e.g. energized substation), document and retain on file. Consult AEP as appropriate Expanding disturbed area (go to page 2 of the flow chart) Document and retain on file Footnote 1: AEP, Release Reporting Guidelines, Page 4 of 4

Environmental Guidelines Checklist

Environmental Guidelines Checklist Environmental Guidelines Checklist Stakeholder: Alberta Environment & Parks (Brian Lambert), AltaLink, ATCO Electric, EPCOR Distribution & Transmission (EDTI) Section Subsection Existing Proposed changes

More information

Decision D ATCO Electric Ltd. Swan Hills F.P.L. 744S Substation Decommission and Salvage. November 8, 2018

Decision D ATCO Electric Ltd. Swan Hills F.P.L. 744S Substation Decommission and Salvage. November 8, 2018 Decision 23890-D01-2018 Swan Hills F.P.L. 744S Substation Decommission and Salvage November 8, 2018 Alberta Utilities Commission Decision 23890-D01-2018 Swan Hills F.P.L. 744S Substation Decommission and

More information

Chapter 4. Airport Authority Governance, Statutes and Policies

Chapter 4. Airport Authority Governance, Statutes and Policies Chapter 4 Airport Authority Governance, Statutes and Policies Table of Contents 4. Airport Authority Governance, Statutes and Policies... 4-1 4.1 The Federal Government and Airport Authorities... 4-1 4.2

More information

ENVIRONMENTAL SCREENING REPORT

ENVIRONMENTAL SCREENING REPORT ENVIRONMENTAL SCREENING REPORT Pursuant to the Canadian Environmental Assessment Act (CEA Act) SCREENING SUMMARY TransCanada PipeLines Limited (TransCanada) is proposing to conduct a contaminant sampling

More information

GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN WATERBODIES AND ON WATERBODY BANKS

GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN WATERBODIES AND ON WATERBODY BANKS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 182 NOVEMBER 2012 GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN WATERBODIES AND ON WATERBODY BANKS TABLE OF CONTENTS

More information

KEY GOVERNING LEGISLATION, STANDARDS AND CODES

KEY GOVERNING LEGISLATION, STANDARDS AND CODES Filed: September, 0 EB-0-00 Tab Page of KEY GOVERNING LEGISLATION, STANDARDS AND CODES.0 INTRODUCTION Hydro One Inc. is subject to direction from its shareholder (the Government of Ontario), Ontario Energy

More information

EPCOR Distribution & Transmission Inc.

EPCOR Distribution & Transmission Inc. Decision 22229-D01-2016 Victoria E511S Substation Breaker Additions December 19, 2016 Alberta Utilities Commission Decision 22229-D01-2016 Victoria E511S Substation Breaker Additions Proceeding 22229 Application

More information

Westridge Marine Terminal Environmental Protection Plan

Westridge Marine Terminal Environmental Protection Plan Westridge Marine Terminal Environmental Protection Plan 1 Westridge Marine Terminal Environmental Protection Plan: Overview What The Environmental Protection Plan (EPP) communicates environmental procedures

More information

Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments

Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments Rule 007 Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments This rule as amended was approved by the Alberta Utilities Commission on June

More information

10.0 Environmental protection, follow-up and monitoring

10.0 Environmental protection, follow-up and monitoring 10.0 Environmental protection, follow-up and monitoring 10.1 Introduction Manitoba Hydro will implement the mitigation measures, monitoring and other follow-up actions identified in chapter 8 through an

More information

Alberta Transportation The City of Edmonton The City of Calgary

Alberta Transportation The City of Edmonton The City of Calgary Alberta Transportation The City of Edmonton The City of Calgary PUBLISHING INFORMATION TITLE: PREPARED BY: DOCUMENT HOLDER: Environmental Construction Operations (ECO) Plan Framework Instructions for

More information

SunEEarth Alberta Solar Development Inc.

SunEEarth Alberta Solar Development Inc. Decision 22422-D01-2017 Yellow Lake Solar Project September 26, 2017 Alberta Utilities Commission Decision 22422-D01-2017 Yellow Lake Solar Project Proceeding 22422 Application 22422-A001 September 26,

More information

Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments

Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments Rule 007 Applications for Power Plants, Substations, Transmission Lines, Industrial System Designations and Hydro Developments This rule as amended was approved by the Alberta Utilities Commission on March

More information

Environmental Assessment Approval. Alton Natural Gas Storage Project

Environmental Assessment Approval. Alton Natural Gas Storage Project Approval Approval Date: Original Dated December 18, 2007 Alton Natural Gas Storage Project Alton Natural Gas Storage LP, Proponent Colchester County, Nova Scotia Alton Natural Gas Storage (the Undertaking

More information

Santoy 8 Satellite Mine at the Seabee Gold Mine. Technical Review Comments. on the. Environmental Impact Statement.

Santoy 8 Satellite Mine at the Seabee Gold Mine. Technical Review Comments. on the. Environmental Impact Statement. Environmental Impact Assessment Technical Review Comments on the Environmental Impact Statement as submitted by Claude Resources Inc. Saskatchewan Ministry of Environment December, 2009 1. INTRODUCTION

More information

Appendix 8. Petroleum Hydrocarbon Products, Ammonium Nitrate and Explosives Management Plan

Appendix 8. Petroleum Hydrocarbon Products, Ammonium Nitrate and Explosives Management Plan Appendix 8 Petroleum Hydrocarbon Products, Ammonium Nitrate and Explosives Management Plan Petroleum Hydrocarbon Products, Ammonium Nitrate, and Explosives Management Plan This Petroleum Hydrocarbon Products,

More information

9.0 Environmental Protection Program

9.0 Environmental Protection Program 9.0 Environmental Protection Program 9.1.1 Overview Manitoba Hydro s Environmental Protection Program (EPP) provides the framework for the delivery, management and monitoring of environmental and socio-economic

More information

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 616. INDUSTRIAL WASTEWATER SYSTEMS SUBCHAPTER 1. INTRODUCTION [AMENDED]

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 616. INDUSTRIAL WASTEWATER SYSTEMS SUBCHAPTER 1. INTRODUCTION [AMENDED] TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 616. INDUSTRIAL WASTEWATER SYSTEMS SUBCHAPTER 1. INTRODUCTION [AMENDED] 252:616-1-1. Purpose 252:616-1-2. Definitions [AMENDED] 252:616-1-2. Definitions

More information

Shell Quest Carbon Capture and Storage Project. Shell Canada Limited

Shell Quest Carbon Capture and Storage Project. Shell Canada Limited SCREENING SCOPING DOCUMENT For the proposed Shell Quest Carbon Capture and Storage Project Shell Canada Limited Prepared by: Canadian Environmental Assessment Agency Natural Resources Canada Fisheries

More information

Canadian Federal Legislation Pertinent to Contaminated Site Management

Canadian Federal Legislation Pertinent to Contaminated Site Management Canadian Federal Legislation Pertinent to Contaminated Site Management Remediation Technologies Workshop 2 Licence to Spill? Banff, AB Oct. 17, 2012 Murray Heap, Environment Canada 1 Federal Legislation

More information

C&B Alberta Solar Development ULC

C&B Alberta Solar Development ULC Decision 22781-D01-2017 Newell Solar Power Plant November 15, 2017 Alberta Utilities Commission Decision 22781-D01-2017 Newell Solar Power Plant Proceeding 22781 Application 22781-A001 November 15, 2017

More information

Under Section 113 of the Environmental Protection and Enhancement Act

Under Section 113 of the Environmental Protection and Enhancement Act Order Made at Slave lake, in the Province of Alberta, on July 13, 2018 ALBERTA ENERGY REGULATOR Under Section 113 of the Environmental Protection and Enhancement Act Under Section 29 of the Pipeline Act

More information

Hydrology and Watershed Management

Hydrology and Watershed Management Hydrology and Watershed Management The summaries and their associated interpretations contained in this document are for general information only, not legal advice. To interpret or apply the law, you must

More information

CHAPTER SURFACE MINING AND RECLAMATION PLAN REGULATIONS

CHAPTER SURFACE MINING AND RECLAMATION PLAN REGULATIONS CHAPTER 19.66 SURFACE MINING AND RECLAMATION PLAN REGULATIONS Section: 19.66.010 PURPOSE AND INTENT 19.66.020 INCORPORATION OF SMARA AND STATE REGULATIONS 19.66.030 APPLICABILITY 19.66.040 EXEMPTIONS 19.66.050

More information

Background Information & Mitigation Guidelines MANURE STORAGE IMPROVEMENTS and MORTALITY MANAGEMENT

Background Information & Mitigation Guidelines MANURE STORAGE IMPROVEMENTS and MORTALITY MANAGEMENT Background Information & Mitigation Guidelines MANURE STORAGE IMPROVEMENTS and MORTALITY MANAGEMENT I. BACKGROUND FOR MANURE STORAGE AND HANDLING SYSTEMS Supplementary Information Form on sizing and safety

More information

Chapter 11: Hazardous Materials A. INTRODUCTION

Chapter 11: Hazardous Materials A. INTRODUCTION Chapter 11: Hazardous Materials A. INTRODUCTION This chapter relies on the analysis from the Fresh Kills Park Final Generic Environmental Impact Statement (FGEIS) and summarizes the conclusions drawn from

More information

Alberta Electric System Operator Yeo 2015S Substation Needs Identification Document

Alberta Electric System Operator Yeo 2015S Substation Needs Identification Document Decision 3476-D01-2015 Alberta Electric System Operator Yeo 2015S Substation Needs Identification Document ATCO Electric Ltd. Yeo Substation Project Facility Application February 18, 2015 Alberta Utilities

More information

Environmental Assessment Matrix

Environmental Assessment Matrix For FCC Use Only Date: Customer Name: Environmental Assessment Matrix Loan Number: Please complete each question. Some answers may require additional information. Attach additional documentation where

More information

STORMWATER MANAGEMENT PLAN CONTENTS CHECKLIST Stormwater Management Plan Contents. SWMP Page # or Reference Location Yes/No

STORMWATER MANAGEMENT PLAN CONTENTS CHECKLIST Stormwater Management Plan Contents. SWMP Page # or Reference Location Yes/No STORMWATER MANAGEMENT PLAN CONTENTS CHECKLIST Stormwater Management Plan Contents Site Description A description of construction activity. The proposed sequence for major activities. Estimates of the total

More information

Alberta Electric System Operator Needs Identification Document Application

Alberta Electric System Operator Needs Identification Document Application Decision 22618-D01-2017 Alberta Electric System Operator Needs Identification Document Application Facility Applications June 22, 2017 Alberta Utilities Commission Decision 22618-D01-2017: Alberta Electric

More information

Facilities Environmental Protection Plan: Burnaby Terminal

Facilities Environmental Protection Plan: Burnaby Terminal Facilities Environmental Protection Plan: Burnaby Terminal 1 Facilities Environmental Protection Plan: Overview What The Environmental Protection Plan (EPP) communicates environmental procedures and mitigation

More information

Preliminary Disclosure; Application for Approval; Operating Permits, Volume 2: Licences and Approvals; and Abandonment Approval and

Preliminary Disclosure; Application for Approval; Operating Permits, Volume 2: Licences and Approvals; and Abandonment Approval and Information required by EUB Guide G-23 1.0 GENERAL INFORMATION 1.1 INTRODUCTION The application should include: a brief project summary, objectives, approvals requested, technical and economic details,

More information

Code of Practice for Exploration Operations

Code of Practice for Exploration Operations Code of Practice for Exploration Operations September 2005 Made under the Environmental Protection and Enhancement Act Published by Alberta Queen s Printer Alberta Queen s Printer Suite 700, Park Plaza

More information

The following potential environmental receptors and impacts form the basis of TRCA s review under Ontario Regulation 166/06 and the Fisheries Act:

The following potential environmental receptors and impacts form the basis of TRCA s review under Ontario Regulation 166/06 and the Fisheries Act: TRCA Technical Guidelines for the Development of Environmental Management Plans for Dewatering September 2013 Rationale: The Technical Guidelines for the Development of Environmental Management Plans for

More information

GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN AND AROUND WATERBODIES AND ON WATERBODY BANKS

GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN AND AROUND WATERBODIES AND ON WATERBODY BANKS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 182 APRIL 2017 GENERAL SPECIFICATION FOR ENVIRONMENTAL PROTECTION FOR CONSTRUCTION IN AND AROUND WATERBODIES AND ON WATERBODY BANKS TABLE OF CONTENTS

More information

Canadian Federal Legislation pertinent to Contaminated Site Management

Canadian Federal Legislation pertinent to Contaminated Site Management Canadian Federal Legislation pertinent to Contaminated Site Management Chinese Brownfields Delegation, Vancouver, British Columbia December 13, 2010 Presented by Paul Ross (paul.ross@ec.gc.ca), Environment

More information

The following potential environmental receptors and impacts form the basis of TRCA s review under Ontario Regulation 166/06 and the Fisheries Act:

The following potential environmental receptors and impacts form the basis of TRCA s review under Ontario Regulation 166/06 and the Fisheries Act: Interim TRCA Technical Guidelines for the Development of Environmental Management Plans for Dewatering September 2013 Rationale: The Technical Guidelines for the Development of Environmental Management

More information

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE 1 Introduction MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE April 9, Primrose/Wolf Lake Oil Sands Project (PAW) is a thermal in situ operation located approximately 65 km north of Bonnyville and about

More information

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE 1 Introduction MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE March 3, 2014 Primrose/Wolf Lake Oil Sands Project (PAW) is a thermal in situ operation located approximately 65 km north of Bonnyville

More information

Appendix M Framework Stormwater Pollution Prevention Plan Prepared by: Idaho Power Company 1221 W Idaho Street Boise, ID 83702

Appendix M Framework Stormwater Pollution Prevention Plan Prepared by: Idaho Power Company 1221 W Idaho Street Boise, ID 83702 Appendix M Framework Stormwater Pollution Prevention Plan Prepared by: Idaho Power Company 1221 W Idaho Street Boise, ID 83702 November 2011 TABLE OF CONTENTS 1.0 INTRODUCTION... 1 2.0 PURPOSE... 1 3.0

More information

Incident Reporting Requirements

Incident Reporting Requirements Incident Reporting Requirements Directive PNG014 December 2016 Version 2.0 Governing Legislation: Acts: The Oil and Gas Conservation Act The Pipelines Act, 1998 Regulations: The Oil and Gas Conservation

More information

RECORD OF SITE CONDITION FREQUENTLY ASKED QUESTIONS. December, 2012

RECORD OF SITE CONDITION FREQUENTLY ASKED QUESTIONS. December, 2012 RECORD OF SITE CONDITION FREQUENTLY ASKED QUESTIONS December, 2012 ISBN: 978-1-4601-0070-7 (Printed version) ISBN: 978-1-4601-0071-4 (On-line version) Web Site: http://environment.gov.ab.ca/info/ Record

More information

PROJECTS ON FEDERAL LANDS. Making a determination under section 67 of the Canadian Environmental Assessment Act, 2012

PROJECTS ON FEDERAL LANDS. Making a determination under section 67 of the Canadian Environmental Assessment Act, 2012 PROJECTS ON FEDERAL LANDS Making a determination under section 67 of the Canadian Environmental Assessment Act, 2012 December 2014 Disclaimer: The approach in this guide is presented as an option and is

More information

CEAA ENVIRONMENTAL ENVIRONMENTAL IMPACT ASSESSMENT AMBASSADOR BRIDGE ENHANCEMENT PROJECT. Replacement Span and Plaza Expansion APPENDIX E

CEAA ENVIRONMENTAL ENVIRONMENTAL IMPACT ASSESSMENT AMBASSADOR BRIDGE ENHANCEMENT PROJECT. Replacement Span and Plaza Expansion APPENDIX E Ambassador Bridge Enhancement Project CEAA ENVIRONMENTAL ENVIRONMENTAL IMPACT ASSESSMENT AMBASSADOR BRIDGE ENHANCEMENT PROJECT Replacement Span and Plaza Expansion APPENDIX E DRAFT EROSION AND SEDIMENT

More information

Saskatchewan Environmental Code Quick Reference Guide

Saskatchewan Environmental Code Quick Reference Guide Saskatchewan Environmental Code Quick Reference Guide [Updated: October 31, 2014] Table of Contents How to use this guide Quick reference and frequently asked questions Division A: General Environmental

More information

The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations

The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations ENVIRONMENTAL MANAGEMENT 1 ENVIRONMENTAL CODE ADOPTION) E-10.22 REG 2 The Environmental Management and Protection (Saskatchewan Environmental Code Adoption) Regulations being Chapter E-10.22 Reg 2 (effective

More information

Terms of Reference. As Required by the Environment Act For Preparation of an Environmental Assessment Report

Terms of Reference. As Required by the Environment Act For Preparation of an Environmental Assessment Report The public is invited to submit comments on this draft Terms of Reference until : Comments should be submitted to : January 21, 2008 Environmental Assessment Branch Nova Scotia Environment and Labour PO

More information

Remediation Certificates 101

Remediation Certificates 101 Remediation Certificates 101 Outline What are they? Regulatory basis for issuing remediation certificates Definitions and brief history of the program Why should I want one? Benefits for the site owner

More information

Chapter 18 Environment Regulating Landfills 1.0 MAIN POINTS

Chapter 18 Environment Regulating Landfills 1.0 MAIN POINTS Chapter 18 Environment Regulating Landfills 1.0 MAIN POINTS As of December 2017, the Ministry of Environment had made progress in addressing the seven outstanding recommendations we initially made in our

More information

Appendix 4. Soil Management Plan

Appendix 4. Soil Management Plan Appendix 4 Soil Management Plan Soil Management Plan This Soil Management Plan (SMP) has been developed for the Giscome Quarry and Lime Plant Project. The SMP is a living document and will be updated as

More information

Eligibility Requirements and Procedures for Risk-Based Remediation of Industrial Sites Pursuant to N.C.G.S. 130A to

Eligibility Requirements and Procedures for Risk-Based Remediation of Industrial Sites Pursuant to N.C.G.S. 130A to Eligibility Requirements and Procedures for Risk-Based Remediation of Industrial Sites Pursuant to N.C.G.S. 130A-310.65 to 310.77 North Carolina Department of Environment and Natural Resources Division

More information

T&D Facilities & Equipment: Environmental Issues - Program 51

T&D Facilities & Equipment: Environmental Issues - Program 51 T&D Facilities & Equipment: Environmental Issues - Program 51 Program Description Program Overview As the nation's electric transmission and distribution (T&D) infrastructure expands and ages, power companies

More information

WATER SUPPLY WELLS - REQUIREMENTS AND BEST MANAGEMENT PRACTICES

WATER SUPPLY WELLS - REQUIREMENTS AND BEST MANAGEMENT PRACTICES December 2009 WATER SUPPLY WELLS - REQUIREMENTS AND BEST MANAGEMENT PRACTICES PIBs # 7333e Note: The numbers and details presented in this manual are current as of the date of publication. Any new regulation

More information

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE. January 10, 2014

MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE. January 10, 2014 1 Introduction MONTHLY UPDATE PRIMROSE OIL SANDS FLOW TO SURFACE January 10, 2014 Canadian Natural Resources Limited Primrose/Wolf Lake Oil Sands Project is a thermal in situ operation located primarily

More information

Alberta Wetland Mitigation Directive

Alberta Wetland Mitigation Directive June 2018 Title: Number: Program Name: Water Policy Branch Effective Date: June 1, 2015 This document was updated on: Disclaimer: June 21, 2018 This publication is issued under the Open Government Licence

More information

Approval and Permitting Requirements Document for Renewable Energy Projects

Approval and Permitting Requirements Document for Renewable Energy Projects Approval and Permitting Requirements Document for Renewable Energy Projects Ministry of Natural Resources September 2009 Approval and Permitting Requirements Document for Renewable Energy Projects Ontario

More information

Alberta Transportation. Environmental Protection Plan for the Planning and Construction of Water and Transportation Projects

Alberta Transportation. Environmental Protection Plan for the Planning and Construction of Water and Transportation Projects Alberta Transportation Environmental Protection Plan for the Planning and Construction of Water and Transportation Projects January 9, 2009 INFTRA Table of Contents Page Table of Contents... i 1.0 INTRODUCTION...1

More information

Appendix D. Fisheries and Oceans Canada (DFO) Letter of Advice

Appendix D. Fisheries and Oceans Canada (DFO) Letter of Advice The City of Winnipeg Bid Opportunity No. 851-2017 Template Version: C420170317 - RW Appendix D Fisheries and Oceans Canada (DFO) Letter of Advice Fisheries and Oceans Canada Pêches et Océans Canada 103-1800

More information

SemCAMS Area Project Description

SemCAMS Area Project Description REGULATORY The Redwillow Pipeline Project involves crossing a provincial boundary, and therefore, approval for it will require the preparation of an application to the NEB. plans to proceed with the regulatory

More information

Reclamation: Legislative / Regulatory Requirements

Reclamation: Legislative / Regulatory Requirements Reclamation: Legislative / Regulatory Requirements Shane Patterson Science and Technology Specialist Land Conservation and Reclamation Policy Branch Outline Conservation & Reclamation 1) Legislation Environmental

More information

Up to 9.5MW AC solar project located near Burdett, Alberta

Up to 9.5MW AC solar project located near Burdett, Alberta PROJECT OVERVIEW Up to 9.5MW AC solar project located near Burdett, Alberta Located on agricultural land within the quarter section NE-21-010-12-W4M near the intersection of Range Road 123 and Township

More information

Standards for SWMF s. (Stormwater Management Facilities) Lacombe County s Guide to Developing Stormwater Management Facilities

Standards for SWMF s. (Stormwater Management Facilities) Lacombe County s Guide to Developing Stormwater Management Facilities Standards for SWMF s (Stormwater Management Facilities) Lacombe County s Guide to Developing Stormwater Management Facilities August 2017 PREAMBLE Development results in a great amount of impervious area,

More information

BACKGROUND INFORMATION. for the INITIAL FEDERAL PUBLIC COMMENT PERIOD. on the

BACKGROUND INFORMATION. for the INITIAL FEDERAL PUBLIC COMMENT PERIOD. on the BACKGROUND INFORMATION for the INITIAL FEDERAL PUBLIC COMMENT PERIOD on the Comprehensive Study pursuant to the Canadian Environmental Assessment Act of the Ajax Mine Project Kamloops, British Columbia

More information

ENVIRONMENTAL ASSESSMENT CHECKLIST

ENVIRONMENTAL ASSESSMENT CHECKLIST ENVIRONMENTAL ASSESSMENT CHECKLIST Date: Prepared By: Name Title Borrower: Address: Real Estate: Owned [/] Yes /No Leased [/] Yes /No Municipal description of property: Legal description, property and

More information

February 19, 2007 DENR SUMMARY OF LANDFILL RECOMMENDATIONS

February 19, 2007 DENR SUMMARY OF LANDFILL RECOMMENDATIONS SUMMARY OF LANDFILL RECOMMENDATIONS 1. Specify how a landfill applicant must demonstrate financial qualifications to construct and operate the landfill. The applicant should provide cost estimates for:

More information

CHAPTER 20.8 SURFACE MINING AND LAND RECLAMATION REGULATIONS

CHAPTER 20.8 SURFACE MINING AND LAND RECLAMATION REGULATIONS CHAPTER 20.8 SURFACE MINING AND LAND RECLAMATION REGULATIONS 20.8.10 PURPOSE AND INTENT... 8-2 20.8.20 INCORPORATION OF SMARA AND STATE REGULATIONS... 8-2 20.8.30 APPLICABILITY...8-2 20.8.40 CONTENTS OF

More information

E16. Trees in open space zones

E16. Trees in open space zones E16. Trees in open space zones E16.1. Background Trees in the open space zones are an important public asset and need to be managed appropriately. As urban areas intensify, open space zones will be relied

More information

City of Valdosta Land Development Regulations

City of Valdosta Land Development Regulations Chapter 324 Section 324-1 Environmental Planning Criteria Protection of Groundwater Recharge Areas (A) Purpose and Intent. Pursuant to O.C.G.A. 12-2-8 and the Georgia Department of Natural Resources (DNR),

More information

Port Granby Project ENVIRONMENTAL ASSESSMENT STUDY REPORT EXECUTIVE SUMMARY

Port Granby Project ENVIRONMENTAL ASSESSMENT STUDY REPORT EXECUTIVE SUMMARY EXECUTIVE SUMMARY Introduction Low-level radioactive waste and associated marginally contaminated soils at Port Granby are part of historical industrial activities in the Port Hope area. Since the 1930s,

More information

ADDRESSING ENVIRONMENTAL CONCERNS DURING THE EAST VILLAGE BROWNFIELD REDEVELOPMENT PROJECT

ADDRESSING ENVIRONMENTAL CONCERNS DURING THE EAST VILLAGE BROWNFIELD REDEVELOPMENT PROJECT Remediation Technologies Symposium October 21 st, 2010 East Village and Fort Calgary circa 2008, looking west Source: CMLC (East Village Master Plan Executive Summary) ADDRESSING ENVIRONMENTAL CONCERNS

More information

Project & Environmental Review. Guidelines Demolition. May 2016

Project & Environmental Review. Guidelines Demolition. May 2016 Project & Environmental Review Guidelines Demolition May 2016 TABLE OF CONTENTS 1. Introduction... 3 2. Objectives... 3 3. Applicability and Building Permits... 3 4. Guidelines for Preparing a Project

More information

FORM 001-A Suspension and Abandonment Cost Estimate Report

FORM 001-A Suspension and Abandonment Cost Estimate Report FORM 001-A Suspension and Abandonment Cost Estimate Report ERCB Licence Number Facility Type (Directive 056, Table 5.1) LSD Location Licence Holder Facility Name Demolition Costs Description Quantities

More information

Conditions Annexed to and Forming Part of Land Use Permit # MV2013C0021

Conditions Annexed to and Forming Part of Land Use Permit # MV2013C0021 Conditions Annexed to and Forming Part of Land Use Permit # MV2013C0021 Part A: Scope of Permit 1. This Permit entitles New Discovery Mines Ltd. to conduct the following land-use operation: a) Use, construction

More information

REASONS FOR DECISION MINISTERIAL APPROVAL PURSUANT TO SECTION 15(1)(a) THE ENVIRONMENTAL ASSESSMENT ACT

REASONS FOR DECISION MINISTERIAL APPROVAL PURSUANT TO SECTION 15(1)(a) THE ENVIRONMENTAL ASSESSMENT ACT REASONS FOR DECISION MINISTERIAL APPROVAL PURSUANT TO SECTION 15(1)(a) THE ENVIRONMENTAL ASSESSMENT ACT SASKATCHEWAN WATER CORPORATION BUFFALO POUND NON-POTABLE WATER SUPPLY SYSTEM EXPANSION PROJECT Introduction

More information

Environmental Setting

Environmental Setting Trans Mountain is seeking approval for a Certificate of Public Convenience and Necessity (CPCN) from the National Energy Board (NEB) for a $5.4 billion expansion of its oil pipeline system from Strathcona

More information

KEEYASK TRANSMISSION PROJECT EA REPORT APPENDIX F DRAFT ENVIRONMENTAL PROTECTION PLAN

KEEYASK TRANSMISSION PROJECT EA REPORT APPENDIX F DRAFT ENVIRONMENTAL PROTECTION PLAN APPENDIX F DRAFT ENVIRONMENTAL PROTECTION PLAN APPENDIX F DRAFT ENVIRONMENTAL PROTECTION PLAN Keeyask Transmission Project Draft Environmental Protection Plan Prepared by: Manitoba Hydro Winnipeg, Manitoba

More information

TOOELE COUNTY LAND USE ORDINANCE CHAPTER 26 Page 1

TOOELE COUNTY LAND USE ORDINANCE CHAPTER 26 Page 1 CHAPTER 26 CONSTRUCTION DEBRIS AND MUNICIPAL SOLID WASTE ZONES Part 26-1. General. 26-2. Construction debris overlay zone (CDO). 26-3. Municipal solid waste zone (MSW). 26-4. Use tables. Part 1 General

More information

Solar Krafte Utilities Inc.

Solar Krafte Utilities Inc. Decision 23323-D01-2018 August 21, 2018 Alberta Utilities Commission Decision 23323-D01-2018 Proceeding 23323 Application 23323-A001 August 21, 2018 Published by the: Alberta Utilities Commission Eau Claire

More information

APPENDIX G. Applicable or Relevant and Appropriate Requirements (ARARs) Revised EE/CA. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area

APPENDIX G. Applicable or Relevant and Appropriate Requirements (ARARs) Revised EE/CA. Lower Duwamish Waterway Superfund Site: T-117 Early Action Area APPENDIX G Applicable or Relevant and Appropriate Requirements (ARARs) Revised EE/CA Appendix G Applicable or Relevant and Appropriate Requirements (ARARS) and Other Requirements to be Considered Table

More information

Mitigating Environmental Impacts in the Offshore Oil and Gas Industry

Mitigating Environmental Impacts in the Offshore Oil and Gas Industry Mitigating Environmental Impacts in the Offshore Oil and Gas Industry Paul Barnes, Manager - Atlantic Canada & Arctic NOTES 2015 St. John s, NL April 27, 2015 Overview Who is CAPP? Oil and Gas Lifecycle

More information

CHAPTER 6 - How to Prepare a SWPPP

CHAPTER 6 - How to Prepare a SWPPP All construction sites which disturb an area of 1 acre or more, currently need a UPDES permit from the State of Utah. As a condition of the permit, a Stormwater Pollution Prevention Plan (SWPPP) must be

More information

KENT BREEZE WIND FARMS

KENT BREEZE WIND FARMS Decommissioning Plan Report MAY 2010 TABLE OF CONTENTS 1. INTRODUCTION... 1 2. DECOMMISSIONING PROCESS DESCRIPTION... 2 3. SITE RESTORATION... 3 4. EXCESS MATERIALS AND WASTE MANAGEMENT... 4 5. MANAGING

More information

CONSTRUCTION SPECIFICATION FOR REMOVAL OF ELECTRICAL EQUIPMENT AND MATERIALS

CONSTRUCTION SPECIFICATION FOR REMOVAL OF ELECTRICAL EQUIPMENT AND MATERIALS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 610 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR REMOVAL OF ELECTRICAL EQUIPMENT AND MATERIALS TABLE OF CONTENTS 610.01 SCOPE 610.02 REFERENCES 610.03

More information

RECLAMATION REGULATIONS

RECLAMATION REGULATIONS RECLAMATION REGULATIONS 1001. INTRODUCTION a. General. The rules and regulations of this series establish the proper reclamation of the land and soil affected by oil and gas operations and ensure the protection

More information

ENVIRONMENT ACT TERMS OF REFERENCE NOVA SCOTIA DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS. Beaver Bank Bypass

ENVIRONMENT ACT TERMS OF REFERENCE NOVA SCOTIA DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS. Beaver Bank Bypass ENVIRONMENT ACT TERMS OF REFERENCE NOVA SCOTIA DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS Beaver Bank Bypass Highway 101 to the Beaver Bank Road Halifax County, NS NOVA SCOTIA DEPARTMENT OF THE ENVIRONMENT

More information

Environmental Guidelines for Preparation of an Environmental Management Plan

Environmental Guidelines for Preparation of an Environmental Management Plan 2013 Environmental Guidelines for Preparation of an Environmental Management Plan Environmental Management Division Environmental Protection Agency 3/13/2013 ENVIRONMENTAL GUIDELINES FOR PREPARATION OF

More information

(B) "Facility," for the purposes of this rule, means:

(B) Facility, for the purposes of this rule, means: 3745-27-13 Procedure to engage in filling, grading, excavating, building, drilling, or mining on land where a hazardous waste facility or solid waste facility was operated. (A) No person shall, without

More information

Spill Prevention Control and Countermeasures Plan Former Raytheon Facility 430 Boston Post Road Wayland, Massachusetts

Spill Prevention Control and Countermeasures Plan Former Raytheon Facility 430 Boston Post Road Wayland, Massachusetts SPCC PLAN Raytheon Company Spill Prevention Control and Countermeasures Plan Former Raytheon Facility 430 Boston Post Road Wayland, Massachusetts 6 November 2002 143.65 Environmental Resources Management

More information

APPENDIX H Guidance for Preparing/Reviewing CEQA Initial Studies and Environmental Impact Reports

APPENDIX H Guidance for Preparing/Reviewing CEQA Initial Studies and Environmental Impact Reports APPENDIX H H.1 Guidance for Preparing and Reviewing CEQA Initial Studies Step 1: Consider the Project Characteristics as Provided by the Project Applicant Review the project application and draft plan

More information

patersongroup Phase I - Environmental Site Assessment Vacant Land, Strandherd Drive at Kennevale Drive Ottawa, Ontario Prepared For Regional Group

patersongroup Phase I - Environmental Site Assessment Vacant Land, Strandherd Drive at Kennevale Drive Ottawa, Ontario Prepared For Regional Group Geotechnical Engineering patersongroup Environmental Engineering Hydrogeology Geological Engineering Materials Testing Building Science Vacant Land, Strandherd Drive at Kennevale Drive Ottawa, Ontario

More information

TECHNICAL REVIEW COMMENTS on the Environmental Impact Statement. Karnalyte Resources Inc. Wynyard Carnallite Project

TECHNICAL REVIEW COMMENTS on the Environmental Impact Statement. Karnalyte Resources Inc. Wynyard Carnallite Project TECHNICAL REVIEW COMMENTS on the Environmental Impact Statement Karnalyte Resources Inc. Wynyard Carnallite Project Prepared by Saskatchewan Ministry of Environment Environmental Assessment Branch December,

More information

SECURE Energy Services Inc. Proposed Conklin Class II Landfill Portions of: NE W4, SE W4 and NW W4

SECURE Energy Services Inc. Proposed Conklin Class II Landfill Portions of: NE W4, SE W4 and NW W4 26 February 2016 RE: SECURE Energy Services Inc. Proposed Conklin Class II Landfill Portions of: NE 23-76-8W4, SE 26-76-8W4 and NW-24-76-8W4 Dear Sir or Madam, SECURE Energy Services Inc. ( SECURE ) is

More information

CCSD#1 Stormwater Standards

CCSD#1 Stormwater Standards SECTION 6 EROSION CONTROL STANDARDS 6.1 INTRODUCTION The policies of this section shall apply during construction and until permanent measures are in place following construction as described herein, unless

More information

DRAFT FINDING OF NO SIGNIFICANT IMPACT. for. Tioga Sports Park

DRAFT FINDING OF NO SIGNIFICANT IMPACT. for. Tioga Sports Park DRAFT FINDING OF NO SIGNIFICANT IMPACT for Tioga Sports Park The U.S. Fish and Wildlife Service (USFWS) prepared an Environmental Assessment (EA) to analyze the potential effects of the proposal by the

More information

Environment ENVIRONMENTAL PROTECTION ORDER NO. EPO SSR. Sears Canada Inc. [Sears] C/O. Lloyd McLellan. Eli Consulting Canada Inc.

Environment ENVIRONMENTAL PROTECTION ORDER NO. EPO SSR. Sears Canada Inc. [Sears] C/O. Lloyd McLellan. Eli Consulting Canada Inc. ENVIRONMENTAL PROTECTION AND ENHANCEMENT ACT BEING CHAPTER E-12 R.S.A. 2000 (the Act ) current registered owner of the Lands; WHEREAS the Lands were purchased by Concord on June 18, 2015 and Concord is

More information

Environmental Assessment Approval

Environmental Assessment Approval Environmental Assessment Approval Approval Date: Original Dated October 1, 2010 Hants County Aggregate Quarry Extension Project Municipal Enterprises Ltd., Proponent Hants County, Nova Scotia The Hants

More information

Code of Practice for Land Treatment of Soil Containing Hydrocarbons

Code of Practice for Land Treatment of Soil Containing Hydrocarbons Code of Practice for Land Treatment of Soil Containing Hydrocarbons September 2008 Made under the Environmental Protection and Enhancement Act RSA 2000, ce-12 Published by Alberta Queen s Printer Alberta

More information

STATE OF MISSOURI CLEAN WATER ACT SECTION 401 WATER QUALITY CERTIFICATION 2012 GENERAL AND SPECIFIC CONDITIONS

STATE OF MISSOURI CLEAN WATER ACT SECTION 401 WATER QUALITY CERTIFICATION 2012 GENERAL AND SPECIFIC CONDITIONS STATE OF MISSOURI CLEAN WATER ACT SECTION 401 WATER QUALITY CERTIFICATION 2012 GENERAL AND SPECIFIC CONDITIONS These conditions ensure that activities carried out under Nationwide Permits (NWPs) do not

More information

Environmental Review Process. Presented by Environment and Natural Resource Unit, Lands and Economic Development, BC Region

Environmental Review Process. Presented by Environment and Natural Resource Unit, Lands and Economic Development, BC Region Environmental Review Process Presented by Environment and Natural Resource Unit, Lands and Economic Development, BC Region Outline 1. Overview of the Canadian Environmental Assessment Act (CEAA) 2. Indigenous

More information

APPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY TECHNICALLY ADMIN.

APPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY TECHNICALLY ADMIN. Revised 02/01 APPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM Facility Name: Facility ID No.: ODEQ Permit No.: Reference No.: _ Application Type: Date: (New/Modify/Renewal)

More information