Test Procedure. I-9312 Starter Kit R-9310 Refill

Size: px
Start display at page:

Download "Test Procedure. I-9312 Starter Kit R-9310 Refill"

Transcription

1 Test Procedure I-9312 Starter Kit R-9310 Refill Midland,VA USA WEB: TEL: (800) FAX: (540) Feb. 16, Rev. 19

2 Contents Section 1 Introductory Information 1.1 Test Method Response to Hydrocarbons... 2 Section 2 Test Instructions 2.1 Safety Information Sample Collection Operating Tips Test Procedure Dilution Procedure Alternative Test Procedure for High Range Hydrocarbon Soil Samples Generation of Standard Curve... 8 Section 3 Instrumentation 3.1 Photometer Battery Replacement Photometer Operating Tips Photometer Displays and Troubleshooting Photometer Specifications Photometer Menu Selection Calibrating the Balance Operating the Timer Balance Features Operating the Timer Timer Features Section 4 Warranty Information 4.1 Warranty Information Introductory Information 1.1 Test Method The RemediAid Total Petroleum Hydrocarbon Test Kit is a rapid, simple field test for measuring petroleum hydrocarbon contamination in soil. The patented test, developed in conjunction with Shell Research, 1,2,3 is based upon the Friedel Crafts reaction with one fundamental difference, the intermediate that is formed in the solvent is the colored species that is measured during the analytical finish. A pre-measured sample of soil is added to a reaction tube which contains anhydrous sodium sulfate, a drying agent. The drying agent is used to improve the subsequent extraction efficiency. The contents of a double point ampoule, 20 ml dichloromethane, is then added to the reaction tube. This organic solvent extracts the petroleum hydrocarbons from the soil sample. In order to remove polar hydrocarbons and color interferences, the soil extract is treated with Florisil. Finally, a vacuum sealed ampoule containing aluminum chloride draws in a predetermined volume of the hydrocarboncontaining solvent through a column containing filtering material that is mounted on the tip of the ampoule. The aromatic hydrocarbons in the solvent react with the aluminum chloride to produce a soluble yellow to brown colored product in direct proportion to the petroleum hydrocarbon concentration in the extract. The absorbance of the extract is measured in a portable, battery powered, LED based colorimeter and converted to mg/kg hydrocarbon in the soil by use of standard conversion values in the following formula: mg TPH/kg = [(A x S) - I] x V W SECTION 1 where, A = Absorbance S = Slope for a specific hydrocarbon mix, mg/l/a I = Intercept for a specific hydrocarbon mix, mg/l V = Extraction Volume; 20 ml (0.02 L) W = Weight of Soil Sample; 5 g (0.005 kg) 1. Shell Internationale Research, European Patent No , U.S. Patent No. 5,834, Roberts, R.M. Khalaf, A. A., Friedel Crafts Alkylation Chemistry; A Century of Discovery. Marcel Dekker, Inc., New York, pp Schmid, George H., Organic Chemistry, 1996, Mosby - YearBook, Inc., QD251.2S354, p

3 1.2 Response to Hydrocarbons The RemediAid Test Kit provides a quicker alternative to the more costly and time consuming standard laboratory methods, but one of the drawbacks to this type of test is that the chemistry is not selective for a particular hydrocarbon. Furthermore, most TPH chemistries are impacted, at least slightly, by various characteristics of the soil itself. Ultimately, the most accurate results are obtained when a site/hydrocarbon specific calibration is generated This kit is designed primarily to be a screening tool, allowing for a comprehensive site survey. Select samples should be sent to a laboratory for confirmatory testing and characterization The RemediAid Test Kit will respond to essentially all hydrocarbon products, as long as they contain some aromatic compounds. This covers nearly all products, with few exceptions (e.g.,household kerosene). The table below lists an average response factor that can be used if the identity of the hydrocarbon contamination in the soil sample is unknown. Calibration Information for SAM Photometers With Inspection Dates After October 10, Hydrocarbon Unleaded Gasoline Diesel Brent Crude Lube Oil BTEX Leaded Gasoline PAH (16 Component mixture) Unknown 1 Slope Intercept MDL (mg/kg) in Soil N/A Range (mg/kg) in Soil This response factor is supplied for use when the identity of the hydrocarbon contaminant in a particular soil sample is unknown. Test results generated using this factor are to be treated as estimates N/A Test Instructions 2.1 Safety Information Read MSDS before performing this test (availabe at Wear protective gloves and safety glasses while performing this test. Avoid inhaling dichloromethane fumes. Do not work in a confined space. Do not eat, drink, or smoke while performing this test. Wash hands thoroughly after performing this test. 2.2 Sample Collection SECTION 2 Methods of collection and sample size should be chosen to ensure that the sample is representative of the location from which it was taken. In many cases, contaminant composition can vary substantially over very short distances, even for relatively homogeneous soils. Sampling strategy will be guided by a number of factors such as prior knowledge of site activities and visual clues. Representativeness can be improved by taking large samples which are then well mixed immediately before being subsampled for analysis. However, sample size should be restricted to a size which can be mixed very quickly in the field so that volatile hydrocarbons are not lost. Any unnecessary agitation of samples should be avoided for this reason. Actual sampling of the soil should be carried out in the minimum possible time, with the least possible handling before the sample is sealed in a container. Samples should be collected in wide necked glass jars so that mixing can be carried out speedily. If possible, collection of an uncontaminated soil sample in close proximity to the sampling location is recommended. This sample would be analyzed according to the test procedure in section 2.4 and would potentially be used to correct for background in test samples, (refer to Section 2.3 under Soil Blank). To avoid cross contamination, care should be taken to ensure that all sampling equipment is decontaminated before each new sample is taken. In many cases, samples will be retained in case subsequent analysis is necessary. Error can also occur by poor labelling of samples. All sample vessels should be clearly labelled with sampling date, site or project identification, identification number, sampling depth and an identifier for the individual doing the sampling. A sampling log should be maintained which includes the sample details above and other details (e.g., sample appearance, color, smell, texture, or any other signs of hydrocarbon contamination). 3

4 2.3 Operating Tips Do not store this product at temperatures above 90 F (32 C). Keep Reagent Blank Ampoule out of direct sunlight. Avoid testing soil at high ambient temperatures (> 80 F or 27 C). CLOUDY TEST AMPOULE: After Step 13 of the test procedure, the ampoule contents should not be cloudy in appearance. Cloudiness is an indication that additional sodium sulfate was needed to remove excess moisture from the soil sample. A cloudy test ampoule will likely give false high test results. Repeat the test procedure using additional sodium sulfate. SOIL BLANK: If an absorbance value of > is obtained for the soil blank, then calculate a test result in mg/kg for the soil blank using the formula in Step 20 of the test procedure. Subtract this value from the result obtained for the sample to prevent positively biased test results caused by background color extracted from the soil. 2.4 Test Procedure 1. Add 5.0 g of the soil to be tested to a Reaction Tube (tube with natural cap). Whenever possible, exclude rocks and other non-soil debris. NOTE: Try to keep balance sheltered from wind. The reaction tube contains anhydrous sodium sulfate which is used to remove moisture from the soil. 2. Cap the reaction tube and shake it to mix the contents to a uniform mixture. NOTE: If the sample is too wet to form a granular, uniform mixture (as with clay soils), add up to 5 scoops of extra sodium sulfate and shake the tube vigorously until a uniform, free-flowing powder is obtained. If necessary, a clean spatula can be used to break up clumps of wet soil. 3. While holding the double-tipped ampoule in a vertical position over the reaction tube, snap the upper tip using the tip breaking tool. Carefully invert the ampoule and position the open end over the reaction tube. Snap the upper tip and allow the contents to drain into the reaction tube. 4. Cap the reaction tube and shake it vigorously for 3 minutes Allow the reaction tube to stand undisturbed while the soil settles to the bottom. This should take approximately 2 minutes. 6. Decant extract to an Extract Clean-up Tube (tube with green cap) using care not to transfer any soil to the clean-up tube. Cap the clean-up tube and shake it for 1 minute. Allow the florisil to settle for approximately 2 minutes. 7. Remove the cap from the clean-up tube and replace it with the Tube Plug/Snapper. This is a round, white plug that has a small hole in the center that will be used to snap the tip of the TPH ampoule. 8. Push a column onto the tip of the ampoule until it fits snugly. 9. Insert the column/ampoule tip assembly through the hole in the plug up to the scoremark on the ampoule tip. While holding the tube, gently pull the ampoule slightly out of the vertical orientation to snap the ampoule tip. The ampoule will slowly draw in liquid from the tube. When filling has stopped, withdraw the column/ampoule assembly from the tube. 10. Using a tissue, carefully remove the column from the tip of the ampoule. Wipe all liquid from the exterior of the ampoule. 11. Place a small silicone ampoule cap firmly onto the tip of the ampoule. 12. Over a period of 10 minutes, invert the ampoule periodically, allowing the bubble to travel from end to end each time. NOTE: Invert the ampoule several times every 1-2 minutes. 5

5 13. Allow the ampoule to stand undisturbed while the crystals settle to the bottom. This should take approximately 10 minutes. NOTE: If the ampoule appears cloudy after the 10 minute wait, wait an additional 5-10 minutes for the cloudiness to settle out of the ampoule. See Operating Tips for additonal information. 14. Insert the Reagent Blank Ampoule, flat end first, into the sample cell compartment of the photometer (with mild downward pressure to ensure that the ampoule is fully seated). 15. Place the light shield over the Reagent Blank Ampoule. 16. Press the Zero/Test Key. The TPH symbol will flash for approximately 8 seconds, then the display will show Insert the test ampoule, flat end first, into the cell compartment of the photometer (with mild downward pressure to ensure that the ampoule is fully seated). 18. Place the light shield over the test ampoule. 19. Press the Zero/Test Key. The TPH symbol will flash for approximately 3 seconds, then the sample absorbance value will appear in the display. 20. If the absorbance value is less than 1.00, then use the following formula to determine the TPH concentration: mg/kg soil = [(A x S) - I] x 4 where, A = Absorbance S = Slope for a specific hydrocarbon mix I = Intercept for a specific hydrocarbon mix If the instrument displays HI, then either the Dilution Procedure (Section 2.5) or the Alternate Test Procedure (Section 2.6) must be performed. 2.5 Dilution Procedure 1. Pipette 2.5 ml of the clear solvent extract from Step 6 into an Extract Clean-Up Tube. 2. Add the contents of a double-tipped ampoule to the Extract Clean-Up Tube. Cap the tube and shake it for 1 minute. Allow the florisil to settle for approximately 2 minutes. 3. Follow Steps 7-19 of the Test Procedure. 4. Use the following formula to determine the TPH concentration: mg/kg soil = [(A x S) - I] x D x 4 where, A = Absorbance S = Slope for a specific hydrocarbon mix I = Intercept for a specific hydrocarbon mix D = Dilution Factor: Alternative Test Procedure for High Range Hydrocarbon Soil Samples 1. Add 1.0 g of the soil to be tested to a Reaction Tube (tall tube with white cap). Whenever possible, exclude rocks and other non-soil debris. 2. Follow steps 2-19 of the Test Procedure. 3. Use the following formula to determine the TPH concentration: mg/kg soil = [(A x S) - I] x 20 where, A = Absorbance S = Slope for a specific hydrocarbon mix I = Intercept for a specific hydrocarbon mix 6 7

6 2.7 Generation of Standard Curve To improve accuracy or to determine a specific hydrocarbon product, a standard curve can be generated. Standard curves are generated from measurement of various hydrocarbon solutions in dichloromethane (DCM) covering the expected range of the test. For heavy hydrocarbons such as crude, lube oil, and diesel, prepare a stock solution (10,000 mg/l) by weighing out 1 g of the hydrocarbon and diluting to 100 ml in DCM. Prepare a series of diluted standard solutions as follows: 50 mg/l (0.5 ml stock in 100 ml DCM) 100 mg/l (1.0 ml stock in 100 ml DCM) 150 mg/l (1.5 ml stock in 100 ml DCM) 200 mg/l (2.0 ml stock in 100 ml DCM) 300 mg/l (3.0 ml stock in 100 ml DCM) 400 mg/l (4.0 ml stock in 100 ml DCM) For lighter (more volatile) hydrocarbons such as gasolines and pure BTEX, it is advisable to prepare the standards volumetrically rather than gravimetrically to reduce volatile losses. To make a particular concentration of dilute standard (e.g., 50 mg/l, which is 5 mg in 100 ml DCM) the needed volume is calculated by dividing the mass required (ex. 5 mg), by the density of the hydrocarbon. The calculated volume (Volume = Mass Density) is then injected into a 100 ml volumetric flask containing DCM. After preparing the appropriate standard solutions: 1. Add 20 ml of each standard to an Extract Clean-Up Tube (containing Florisil) and perform the Test Procedure beginning with Step 7. NOTE: When running standards in DCM, it takes at least 20 minutes for the crystals to settle in Step 13 of the test procedure. 2. Construct a calibration curve using the absorbance values for each standard. 8 Instrumentation 3.1 Photometer Battery Replacement Instrument Back Batteries Notch To ensure that the instrument is water proof: seal ring (A) must be in position battery compartment cover (B) must be fixed with the four screws 3.2 Photometer Operating Tips Upon start up, the photometer automatically proceeds to the zeroing process. Every time the photometer powers on, it must be re-zeroed. To re-zero the photometer, it must be turned off and back on again. A series of readings can be taken without re-zeroing, as long as the photometer stays on during the series. Protect photometer from extreme humidity, corrosive fumes and dusty areas. Store in a cool, dry place. Remove the batteries when photometer is not in use. If the batteries are removed for more than one minute the date and time menu starts automatically when the photometer is turn on the next time Photometer must be turned off and back on again for re-zeroing. However, re-zeroing is not necessary when reading a series of samples. Press the! key to turn the display back light on or off. When moving the photometer from one temperature extreme to another, wait at least 10 minutes to allow photometer to come to temperature equilibrium. Contamination of the transparent sample chamber will result in incorrect measurements. The sample chamber should be checked at regular intervals and cleaned as necessary. Use a soft moist cloth or cotton swab to clean. If the sample cell adapter has been removed, it must be replaced with proper orientation aligning the triangle on the adapter with the triangle on the photometer. 9 SECTION 3 Battery Compartment Cover (B) Seal Ring (A) Screws

7 3.3 Photometer Displays and Troubleshooting E01: Light absorption too great (dirty optics) E20/E21: Too much light reaching detector E22 or Battery Icon: Battery should be replaced btlo: Battery capacity is too low for the display backlight Hi/EO3: Measuring range exceeded or excessive turbidity Lo: Test result has a negative value E27/E28/E29: Instrument zeroed incorrectly, dirty optics or failing light source. 3.4 Photometer Specifications Auto Shut Off: After 15 minutes of non-use Optics: 430 nm LED/interference filter and photosensor in transparent sample chamber Operating Temp.: 5 to 40 C (41 to 104 F) Battery: 4 AAA batteries (approx. 5,000 tests or 17 hours) Waterproof: Floating, IP68 (1 hour at 0.1 meter) Wavelength Accuracy: ± 1 nm Photometric Accuracy*: 3% FS (T = 20 C - 25 C) / (T = 68 F - 77 F) Photometric Resolution: 0.01 A Ambient Conditions: Temperature 5-40 C / F Rel. humidity % (non-condensing) CE: Certificate of Declaration of CE-Conformity available upon request. * Measured with Standard Solutions 3.5 Photometer Menu Selection 1. Hold the Mode key down and press the On/Off key. Allow the 3 decimal points to appear in the display before releasing the Mode key. 2. Use the! key to toggle through 2 menu options: Store = recall stored data Date & Time = setting the date and time. 3. Press the Mode key to select the menu option that is indicated by the arrow. Note: If the instrument is already on, press and hold the! key for more than 4 seconds to access the recall menu. Recall of Stored Data The colorimeter shows the last 16 data sets in the following format: Sample Number: nxx (XX: 16, 15, 14,...1) Year: XXXX (i.e. 2009) Date: mm.dd (i.e ) Time: hh:mm (i.e. 12:05) Result: XX or XXX 10 The Zero/Test key repeats the current data set. The Mode key scrolls through all stored data. Quit the menu by pressing the! Key. Setting Date and Time The setting starts with the year (XXXX), then month (XX), then day (XX), then hour (XX), then minutes (XX). Increase value by pressing the Mode key. Decrease value by pressing the Zero/Test key. Proceed to the next setting by pressing the! key. After setting the minutes and pressing the! key, the display will show "IS SET" and return to measurement mode. 3.6 Calibrating the Balance For best results, calibrate at regular intervals, especially if the scale is in use for prolonged periods. 1. Press the On/Off button to turn the instrument on. 2. Press and hold the Unit/Cal button until the display shows CAL, then release. 3. Press the On/Off button. The display will show C When the display shows C 100 place the calibration weight on the platform. 5. Press the On/Off button. PASS will be displayed when calibration is complete. Note: If the calibration steps are not followed correctly or if the wrong weight is used, the display will show CAL E. Repeat the procedure. 3.7 Operating the Balance 1. Push the blue balance tray toward the back of the scale until it clicks into place. Pointers on the side of the tray will align with symbols on the bottom of the scale. 2. Place a reaction tube on the center of the balance tray. 3. Press the On/Off button and the display will show Proceed to weigh out the 5.0 g of soil needed in the Test Procedure. 3.8 Balance Features On/Off: Pressing this button turns the scale on. Pressing and holding this button turns the scale off. 11

8 Zero/On/Off: This key is also used to rezero the display when the scale is on. Unit/Cal: Press this button briefly to change the weighing unit. The following weight units may be selected: grams (g), ounces (oz), pennyweight (dwt) or troy ounces (oz t). Pressing and holding this button begins the calibration process. 3.9 Operating the Timer Note: The installed battery is insulated by tape to give maximum battery life. To use the timer, remove the tape from the battery compartment. 1. Press the CLOCK button until all channels display the timer mode. 2. Press and hold the CHANNEL button (1, 2, or 3) for three seconds. Display will flash. 3. Press the MIN (minute) button to set the countdown time required. Display will flash. 4. Press the CHANNEL button to confirm the entry. Display stops flashing. 5. Press the CHANNEL button (1, 2 or 3) to start countdown timing. 6. Press any button to silence the alarm Timer Features Each channel has a unique alarm to indicate which channel is alarming. Channel 1 emits a single beep, Channel 2 emits 2 beeps, etc. The ALL TIME button allows you to start or stop all channels simultaneously. The CLEAR button sets all stopped channels to 00:00:00. The ALARM DURATION switch, located in the battery compartment, allows for a choice between an alarm that sounds for 1 minute and then automatically shuts off and an alarm that sounds continuously until manually silenced There are two volume settings. Slide the VOL button to the upper position for high volume alarm, or to the lower position for low volume alarm. If the unit does not function properly for any reason install a new AAA alkaline battery Warranty Information SECTION 4 The TPH Photometer, Balance and Timer all carry an unconditional guarantee of freedom from defects in materials and workmanship for a period of one year from the date of the shipment. User access to the interior of these devices may impair their function and will void this warranty. Improper use, application, or servicing also voids this warranty. Manufacturer's liability shall not exceed cost of replacement of the device. The manufacturer generally warrants its products, other than instrumentation, to be free from defects in materials and workmanship for a period of two years from the date of the shipment. Return authorization must be obtained prior to returning any merchandise. If you have any questions concerning the operation and maintenance of the device or the reagent accessories, contact an authorized dealer for assistance. The manufacturer offers to replace any product which it manufactures in defective condition. This is the exclusive remedy for damages of any nature, including incidental and consequential, resulting from such products. THIS WARRANTY SHALL BE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. 13

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter OWNERS MANUAL Micro TPI Field Portable Turbidimeter HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 Email: Info@hfscientific.com Manual Part No. 22666 (12/04)

More information

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at USER MANUAL ExStik CL200A Waterproof Total Residual Chlorine Tester Patent Pending Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the ExStik

More information

OPERATING INSTRUCTIONS. Portable Turbidity Meter

OPERATING INSTRUCTIONS. Portable Turbidity Meter OPERATING INSTRUCTIONS Portable Turbidity Meter ELE International Chartmoor Road, Chartwell Business Park, Leighton Buzzard Bedfordshire, LU7 4WG England Sales: Civil +44 (0) 870 777 7706 Sales: Env. +44

More information

Opti-Check Handheld Fluorometer

Opti-Check Handheld Fluorometer Opti-Check Handheld Fluorometer November 11, 2011 P/N: 998-0861 Revision A TURNER DESIGNS 1995 N. 1 st Street San Jose, CA 95112 Phone: (408) 749-0994 FAX: (408) 749-0998 Table of Contents 1. Introduction

More information

DS-520 Digital Indicator Operation Manual 73366

DS-520 Digital Indicator Operation Manual 73366 DS-520 Di gi tal Indi cator Operation Manual 73366 SECTION DS-520 SERIES OPERATING MANUAL INDEX PAGE NUMBER 1.0 GENERAL 2-3 1.1. Features 2 1.2. Keyboard & Display Layout 2 1.3. Key Switch Information

More information

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g)

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g) American Weigh Scales MiniCD User Manual MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.0 MiniCD User Manual Thank you for purchasing the

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale Instruction Manual DRS220 Digital Refrigerant Scale DRS220 Digital Refrigerant Scale Limited Warranty The DRS220 Digital Refrigerant Scale is warranted to be free from defects in materials and workmanship

More information

INSTRUCTIONS & CALIBRATION PHOTOBOOK

INSTRUCTIONS & CALIBRATION PHOTOBOOK INSTRUCTIONS & CALIBRATION PHOTOBOOK Copyright, Hanby Environmental, LLC 2012 Table Of Contents Included in your Kit / A Note on Soil Sampling..Page 4 Kit Instruc ons... Pages 5-7 Calibra on Photos Standards......

More information

Instruction Manual HI Portable ph/ec/tds/ C Meters

Instruction Manual HI Portable ph/ec/tds/ C Meters Instruction Manual HI 9811-5 Portable ph/ec/tds/ C Meters www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter.

More information

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO Instruction Manual Portable Logging Turbidity Meter with RS232 % TIME LOG LOBAT 188 MAN93703-11R1 08/05 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully

More information

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 Professional Weighing Equipment MRW SERIES intelligent weighing scale WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 WITH PIECE COUNTING FUNCTION Operation Manual Section Table of Contents Page

More information

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010. The Biology CRO Protein Staining System For electric staining of proteins in mini polyacrylamide gels Version 1.0 April 3, 2010 User Manual Table of Contents Product Contents 1 Product Specifications 3

More information

8000 / 8100 ph Meters

8000 / 8100 ph Meters 8000 / 8100 ph Meters Operating Instructions GETTING STARTED To begin taking measurements, connect the probe(s) to the socket(s) on the instrument and remove the cap or bottle covering the electrode. Please

More information

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Revision 06/03/13 486696-PLUSK Kit Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Use in accordance with U.S. Patent #7,333,194 &

More information

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters Instruction Manual HI 9812-0 HI 9812-5 Portable ph/ec/tds/ C Meters w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully

More information

NOTES TABLE OF CONTENTS

NOTES TABLE OF CONTENTS NOTES TABLE OF CONTENTS 1.0 Measuring procedure.. 2 2.0 Design of the device 4 3.0 Calibration curves 5 4.0 Activation of the super user function.. 6 5.0 Changing batteries.. 7 6.0 Determination of the

More information

Universal Tactical Light

Universal Tactical Light M2 Universal Tactical Light Operator s Manual MADE IN THE USA WARNINGS 1. Before handling the firearm or the M2 UTL, read and understand the entire contents of the firearm and M2 UTL Operator s Manuals,

More information

Human IgG ELISA Quantitation Set

Human IgG ELISA Quantitation Set Human IgG ELISA Quantitation Set Cat. No. E80-104 Components Supplied Affinity purified Goat anti-human IgG-Fc Coating Antibody A80-104A, 1 ml at 1 mg/ml Human Reference Serum, RS10-110-4, 0.1 ml HRP Conjugated

More information

Inscale Measurement Technology Ltd Tel: Fax:

Inscale Measurement Technology Ltd Tel: Fax: TCC SERIES Inscale Measurement Technology Ltd 7 Heron Close, St. Leonards-on-Sea. East Sussex TN38 8DX United Kingdom Tel: +44(0)1424 200722 Fax: +44(0)1424 443976 Email: sales@inscale-scales.co.uk Http:www.inscale-scales.co.uk

More information

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell Hardness, Total DOC316.53.01045 Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method 8374 4 to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell Scope and application: For boiler and ultrapure

More information

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters. Iron, Ferrous DOC316.53.01049 1,10-Phenanthroline Method 1 Method 8146 0.02 to 3.00 mg/l Fe 2+ Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater, seawater, brine solutions,

More information

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07 Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Version 1.07 Metertech Inc. provides this publication as is without warranty of any kind, either express or implied, including, but

More information

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb) American Weigh Scales PK-110 User Manual PK-110 (0-44lb x 0.05lb / 44-110lb x 0.1lb) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.1 PK-110 Manual Thank you for purchasing the

More information

DETERMINATION of the EMPIRICAL FORMULA

DETERMINATION of the EMPIRICAL FORMULA DETERMINATION of the EMPIRICAL FORMULA One of the fundamental statements of the atomic theory is that elements combine in simple whole number ratios. This observation gives support to the theory of atoms,

More information

64C Amplification Block. Instruction Manual

64C Amplification Block. Instruction Manual 64C Amplification Block Instruction Manual Caution: All rights reserved. Quidel Corporation reserves the right to modify this manual at any time without notice. Any part of the manual shall not be duplicated,

More information

2.0. User Manual. Protein Staining System. Mar 28, For fast Coomassie blue staining of proteins in mini polyacrylamide gels

2.0. User Manual. Protein Staining System. Mar 28, For fast Coomassie blue staining of proteins in mini polyacrylamide gels 2.0 Protein Staining System For fast Coomassie blue staining of proteins in mini polyacrylamide gels Mar 28, 2012 User Manual GenScript USA Inc. 860 Centennial Ave. Piscataway, NJ 08854 Tel: 732-885-9188,

More information

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems A49108AE May 2015 AB Sciex Pte. Ltd and its affiliates disclaims all warranties with respect to this document, expressed or implied, including

More information

ecosphere water purifier 3in1 USER MANUAL

ecosphere water purifier 3in1 USER MANUAL ecosphere water purifier 3in1 USER MANUAL TABLE OF CONTENTS System Components 3 Function Overview 4 How to Set up Your Purifier 6 3in1 Cartridge Set Up 7 Initial Run 8 Use 8 Purified Water 8 Tap Water

More information

AssayMax Mouse Transferrin ELISA Kit

AssayMax Mouse Transferrin ELISA Kit AssayMax Mouse Transferrin ELISA Kit Assaypro LLC 3400 Harry S Truman Blvd St. Charles, MO 63301 T (636) 447-9175 F (636) 395-7419 www.assaypro.com For any questions regarding troubleshooting or performing

More information

Visit us at

Visit us at testo 606-2 Instruction manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Short manual testo 606-2 11 Short manual testo 606-2

More information

Instruction Manual HT 24 BM-D2400 Homogenizer

Instruction Manual HT 24 BM-D2400 Homogenizer Instruction Manual HT 24 BM-D2400 Homogenizer Foreword Thank you for purchasing a HT 24 Homogenizer. This manual contains instructions for the proper operation and care of this instrument. Please read

More information

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe MODELS: EST712, EST813, EST914, EST916, EST149, EST1014, EST1814, EST2014, WEST149, WEST2114 Read Contents Carefully

More information

Human Collagen Type III (COL3) ELISA

Human Collagen Type III (COL3) ELISA Human Collagen Type III (COL3) ELISA For the quantitative determination of human COL3 in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-61018 For Research Use Only. Not for use

More information

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION SILASEC WP0001 REVISED: JANUARY 2002 DESCRIPTION Bondall Silasec is a concentrated liquid waterproofing compound designed to be used with Portland type A or type GP cements to form a permanent waterproof

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical , TNTplus 820, 10211 DOC316.53.01103 USEPA Reactor Digestion Method Method 10211 ULR (1 60 mg/l COD) TNTplus 820 Scope and Application: For wastewater, process water, surface water, and cooling water;

More information

DIGITAL PORTION SCALE PS-5 OWNER S Manual

DIGITAL PORTION SCALE PS-5 OWNER S Manual DIGITAL PORTION SCALE PS-5 OWNER S Manual CARDINAL SCALE MFG. CO. 8528-M013-O1 Rev G PO BOX 151 WEBB CITY, MO 64870 Printed in USA 09/00 PH (417) 673-4631 FAX (417) 673-5001 Web Site - http://www.detectoscale.com

More information

Please read and follow the instructions below carefully to ensure proper setup and avoid problems.

Please read and follow the instructions below carefully to ensure proper setup and avoid problems. Ink Fill and Use Instructions for the Continuous Ink System (CIS) for the Epson Artisan 1430 Series Printer Please read and follow the instructions below carefully to ensure proper setup and avoid problems.

More information

WS 10 Weighing indicator USER MANUAL

WS 10 Weighing indicator USER MANUAL WS 10 Weighing indicator USER MANUAL Edition:10052001A Safety Instruction For safety operation follow the safety instructions. WARNING Setting, Calibration Inspection and Maintain of the indicator is prohibited

More information

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric) METHOD #: 370.1 TITLE: Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric) ANALYTE: Silica, SiO 2 INSTRUMENTATION: Spectrophotometer STORET No. Dissolved 00955 1.0 Scope and Application

More information

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856 , TNTplus856, 10220 DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and Application: For Water and Wastewater Test preparation Before starting the test: DR 2800:

More information

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm Document: AND016 04 2014 Cadmium Testing and On Site Calibration for Water Testing Detection Range: 0.1 1.0ppm April, 2014 Edition 3 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of

More information

AssayMax Human Transferrin ELISA Kit

AssayMax Human Transferrin ELISA Kit AssayMax Human Transferrin ELISA Kit Assaypro LLC 3400 Harry S Truman Blvd St. Charles, MO 63301 T (636) 447-9175 F (636) 395-7419 www.assaypro.com For any questions regarding troubleshooting or performing

More information

Human Angiotensin 2 (Ang2) ELISA

Human Angiotensin 2 (Ang2) ELISA Human Angiotensin 2 (Ang2) ELISA For the quantitative determination of human Ang2 in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-52748 For Research Use Only. Not for use in

More information

Engineered Systems & Designs TURBIDITY METER

Engineered Systems & Designs TURBIDITY METER Engineered Systems & Designs TURBIDITY METER Operator s Manual for Model 800 Turbidimeter Model 800 with Optional Battery Pack and Carrying Case INDEX Specifications for Turbidity.................. 1 Introduction..............

More information

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls Copper DOC316.53.01039 USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P. O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 E-mail : globalw@globalw.com WS700 Sampler 01-455

More information

HOBO Plug Load Logger (UX ) Manual

HOBO Plug Load Logger (UX ) Manual HOBO Plug Load Logger (UX120-018) Manual The HOBO Plug Load logger is designed to monitor energy consumption of AC-powered plug in loads. This compact device can be used as a power meter with its built-in

More information

Advanced Photometer System

Advanced Photometer System Revision 06/07/2 Standard Kit Starter Kit Advanced Photometer System IDEAL FOR TESTING POOLS AND SPAS. ACCEPTED BY MOST HEALTH DEPARTMENTS FOR COMMERCIAL POOL AND SPA TESTING. USEPA, DIN, & ISO Compliant

More information

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN 1.1 Scope and Application 1.1.1 This spectrophotometric method is used in the determination of chlorophyll a, b, and c, and pheophytin a. This method can be used

More information

HY-ALERTA 500 Handheld Hydrogen Leak Detector

HY-ALERTA 500 Handheld Hydrogen Leak Detector HY-ALERTA 500 Handheld Hydrogen Leak Detector Our Mission Deliver unsurpassed value and optimize green initiatives with our one of a kind continuous hydrogen-specific sensing technology worldwide. Our

More information

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010) Adam Equipment LBH SERIES (P.N. 700660113, Revision B2, January 2010) Adam Equipment Company 2010 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed

More information

Copper Odyssey. Chemical Reactions of Copper

Copper Odyssey. Chemical Reactions of Copper Name Lab Partner(s) Copper Odyssey Chemical Reactions of Copper Date Period Elemental copper metal will be converted into copper (II) ion and then brought through a series of compound conversions until

More information

Stopwatch Display Timer Owner s Manual

Stopwatch Display Timer Owner s Manual The Leader in Event Critical Timing Electronics Stopwatch Display Timer Owner s Manual Rev H RaceAmerica Corporation P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com info@raceamerica.com

More information

Mouse Peptide YY (PYY) ELISA

Mouse Peptide YY (PYY) ELISA Mouse Peptide YY (PYY) ELISA For the quantitative determination of mouse PYY in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-58705 For Research Use Only. Not for use in diagnostic

More information

Aflatoxin M1 ELISA Test Kit Manual Catalog #:

Aflatoxin M1 ELISA Test Kit Manual Catalog #: BIOO FOOD AND FEED SAFETY Aflatoxin M1 ELISA Test Kit Manual Catalog #: 1060-02 This kit is manufactured to the international quality standard ISO 9001:2008. ISO CI#: SARA-2009-CA-0114-01-B BIOO Scientific

More information

Human Myostatin, ELISA Kit (MSTN)

Human Myostatin, ELISA Kit (MSTN) Human Myostatin, ELISA Kit (MSTN) 96 Tests Catalog Number: MBS733837 Store all reagents at 2-8 C Valid Period: six months For samples: Cell culture fluid & body fluid & tissue homogenate Serum or blood

More information

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation USER MANUAL Contents Safety Precautions. 3 Cabinet Assembly 4 Operating buttons / functions.5-6 Machine Operation...7-11 Convert from Inches to Millimeters / Millimeters to Inches.. 7 Programming in Manual

More information

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

Adhesion Promoter/Primer 3M Adhesion Promoter AP596 Adhesion Promoter/ 3M Adhesion Promoter AP596 3M All Purpose P591 3M Metal P592 Technical Data October 2017 Product Description 3M Adhesion Promoter AP596 and 3M s P591, P592, and are low viscosity adhesion

More information

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

TURBIDITY TB 300 IR TB 210 IR TB 250 WL.  General Catalogue April 2015 TURBIDITY 128 TB 300 IR TB 210 IR TB 250 WL www.lovibond.com General Catalogue April 2015 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid or solid

More information

PTSV403. Camera Parking Assist System. Camera PTSV

PTSV403. Camera Parking Assist System. Camera PTSV PTSV403 Camera Parking Assist System PTSV403 75545485 Camera Sensor Contents Reasons to choose Steelmate User's Manual Reasons to choose Steelmate -------------------- Disclaimer --------------------------------------------

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

Human IL-6 ELISA Test Kit Manual Catalog #: 2107 Reference #:

Human IL-6 ELISA Test Kit Manual Catalog #: 2107 Reference #: Human IL-6 ELISA Test Kit Manual Catalog #: 2107 Reference #: 2107-01 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life...

More information

Barkeep Instructions for the Escali SmartConnect Scale

Barkeep Instructions for the Escali SmartConnect Scale Barkeep Instructions for the Escali SmartConnect Scale These instructions are for users of the Escali SmartConnect Kitchen Scale purchased from barkeepapp.com. Users of any other digital scales and/or

More information

Self-cleaning Turbidity Sensor

Self-cleaning Turbidity Sensor 00713589 Self-cleaning Turbidity Sensor Safety Precautions Please read this entire instruction sheet before operating this sensor. Pay particular attention to all danger and caution statements. Failure

More information

QIAfilter Plasmid Midi Kit (Cat #: 12243)

QIAfilter Plasmid Midi Kit (Cat #: 12243) QIAfilter Plasmid Midi Kit (Cat #: 12243) Things to do before starting Add the provided RNase A solution to Buffer P1 before use. Use one vial of RNase A (centrifuge briefly before use) per bottle of Buffer

More information

QuickTox Kit for Fumonisin Flex

QuickTox Kit for Fumonisin Flex QuickTox Kit for Fumonisin Flex Catalog AQ 311 BG Part # 12210, 12239 Matrices and Detection Ranges: Matrix Group ID FM MG1 - Corn FM MG2 - DDGS FM MG3 Corn Flour FM MG4 Corn Common Extraction Protocol

More information

Model M120 Mini Temperature/Humidity Meter

Model M120 Mini Temperature/Humidity Meter Model M120 Mini Temperature/Humidity Meter 2 Table of Contents 1 INTRODUCTION... 3 1.1 The M120 features:... 3 2 SAFETY SUMMARY... 4 3 COMPLIANCE STATEMENTS... 5 4 PRODUCT CONTENTS AND INSPECTION... 5

More information

testo 616 Appareil de mesure de l'humidité

testo 616 Appareil de mesure de l'humidité testo 616 Materialfeuchte-Messgerät Material moisture measuring instrument Appareil de mesure de l'humidité des matériaux. Bedienungsanleitung Instruction manual Mode d emploi Content 17 Content General

More information

LSBio TM Human Anti-Chlamydia pneumoniae antibody (IgG) Direct ELISA Kit. Catalog No. LS-F User Manual

LSBio TM Human Anti-Chlamydia pneumoniae antibody (IgG) Direct ELISA Kit. Catalog No. LS-F User Manual LSBio TM Human Anti-Chlamydia pneumoniae antibody (IgG) Direct ELISA Kit Catalog No. LS-F10326 User Manual Please Read the Manual Carefully Before Starting your Experiment For research use only. Not approved

More information

MEDIZINTECHNIK FÜR TIERÄRZTE

MEDIZINTECHNIK FÜR TIERÄRZTE GB Tabel of contents: Operation Instructions Electronic Platfoorm Balances MEDIZINTECHNIK FÜR TIERÄRZTE 1 Technical data 17 2 Fundamental information (general) 18 2.1 Intended use 18 2.2 Inappropriate

More information

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA KAMIYA BIOMEDICAL COMPANY Mouse Gonadotropin Releasing Hormone (GnRH) ELISA For the quantitative determination of mouse GnRH in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-58182

More information

USER'S GUIDE TO OPERATION

USER'S GUIDE TO OPERATION 35mW 633nm HELIUM-NEON LASER SYSTEM USER'S GUIDE TO OPERATION Research Electro-Optics, Inc. 5505 Airport Boulevard Boulder, Colorado 80301 Phone - (303) 938-1960 Fax - (303) 447-3279 UNPACKING... 3 SHIPPING

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Water-Water Titration for the MicroCal ITC200

Water-Water Titration for the MicroCal ITC200 Water-Water Titration for the MicroCal ITC200 Goal: Water-Water titrations are a good way to check for possible problems, especially the cleanliness of the ITC and your skills in cell filling. If a water-water

More information

The determination of copper in brass

The determination of copper in brass The determination of copper in brass Objective - To determine the amount of copper in a brass sample Background Brass is an alloy made of copper and zinc. Most brass contains about 60% copper. The proportions

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200

More information

DATA LOGGER Model DL-SA11

DATA LOGGER Model DL-SA11 DATA LOGGER Model DL-SA11 User s Manual Felix Storch, Inc. An ISO 9001:2008 registered company 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com R3-081016 1 Product Overview This data logger

More information

Stopwatch Display Timer Owner s Manual

Stopwatch Display Timer Owner s Manual Stopwatch Display Timer Owner s Manual Models 4432SC & 6432SC Rev A RaceAmerica Corp. 280 Martin Ave. Unit#1 Santa Clara, CA 95050 (408) 988-6188 www.raceamerica.com info@raceamerica.com Copyright 2006

More information

Sby SR Instruments, Inc.

Sby SR Instruments, Inc. Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF

More information

testo Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções

testo Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções testo 606-2 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções de en fr es it pt Short manual testo 606-2 11 Short manual testo 606-2

More information

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches Switch-Tek Sump Float Level Switches LV41 & LV42 Series Manual LV41 Series Shown LV42 Series Shown Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507 w flowline.com

More information

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

PORTABLE ph METER PRICE CODE NUMBER MODEL 100 PORTABLE METER MODEL 100 PRICE CODE NUMBER 56-0032 Refer to Bulletin A-301. OPERATION AND SERVICE GUIDE O-670A DEC. 1997 GENERAL INFORMATION Model 100 meter is designed for measuring over the entire 0

More information

High Precision Balances. Operation Manual

High Precision Balances. Operation Manual High Precision Balances Operation Manual BN / CN-en, V5.1-2011 TABLE OF CONTENTS I. Overview ---------------------------------------- 1 II. Specifications and performance --------------- 1 III. Preparations

More information

Chapter 8. Gravimetric Analysis

Chapter 8. Gravimetric Analysis Chapter 8 Gravimetric Analysis Gravimetric analysis is the use of weighing to determine the amount of a component in your sample. Gravimetric analysis, or gravimetry is normally performed either as a :

More information

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Experiment 13: Determination of Molecular Weight by Freezing Point Depression 1 Experiment 13: Determination of Molecular Weight by Freezing Point Depression Objective: In this experiment, you will determine the molecular weight of a compound by measuring the freezing point of a

More information

QuickTox Kit for T-2 / HT-2 Flex

QuickTox Kit for T-2 / HT-2 Flex QuickTox Kit for T-2 / HT-2 Flex Catalog AQ 314 BG Part #12206, 12240 Matrices and Detection Ranges: Matrix Group ID Matrices Limit of Detection Assay Range Range with Dilution* (LOD)^ T-2 MG3 Corn 50

More information

Reagent Kit Selection Guide

Reagent Kit Selection Guide Reagent Kit Selection Guide Introduction The BioChain Nucleic Acid Preparation Technology Introduction BioChain Institute Inc. specializes in developing advanced, efficient and reliable technologies in

More information

Instructions for Use Reprocessed Balloon Inflation Devices

Instructions for Use Reprocessed Balloon Inflation Devices Reprocessed by Instructions for Use Reprocessed Balloon Inflation Devices Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

More information

QuickTox Kit for Aflatoxin Flex

QuickTox Kit for Aflatoxin Flex QuickTox Kit for Aflatoxin Flex Catalog AQ 309 BG Part #12376, 12377 Matrices and Detection Ranges: Matrix Group ID AF MG1 - Corn AF MG2 - DDGS AF MG3 - Peanut (high sensitivity) Protocol Results reported

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P. O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 E-mail : globalw@globalw.com WS750 Sampler 01-457

More information

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 2010B 3500B 2020B The VAREC Vapor Control Inc. 2010B/2020B/3500B Series pressure and/or vacuum relief valves have not been tested

More information

LABORATORY 3 SOIL ANALYSIS

LABORATORY 3 SOIL ANALYSIS VEGETATION DESCRIPTION AND ANALYSIS 2017 LABORATORY 3 SOIL ANALYSIS OBJECTIVE This lab will obtain four key soil parameters from the samples collected from Shawnee Gowan s Grizzly Glacier project relevés.

More information

Human TNF-α ELISA Test Kit Manual Catalog #: 2105 Reference #:

Human TNF-α ELISA Test Kit Manual Catalog #: 2105 Reference #: Human TNF-α ELISA Test Kit Manual Catalog #: 2105 Reference #: 2105-01 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life...

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

Owner s Manual.

Owner s Manual. Owner s Manual Introduction Features / Benefits Records Specifications Warnings Controls / Diagrams Setting Up the Unit Operating the Unit Maintaining the Unit Consumer Information Warranty Information

More information

Odyssey Conductivity & Temperature Logger.

Odyssey Conductivity & Temperature Logger. Odyssey Conductivity & Temperature Logger. Contents. Salinity Sensor & Software.... 2 Conductivity Cell Calibration.... 2 Standard Solutions.... 3 Temperature Coefficient... 5 Positioning the Cell....

More information

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com TM For complete product manual: www.omega.com/manuals/manualpdf/m5440.pdf Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info OM-90 SERIES Portable Temperature

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical without chloride removal, 10067 Manganese III Reactor Digestion Method (without chloride removal) 1 30 to 1000 mg/l COD Mn Scope and Application: For water and wastewater 1 U.S. Patent 5,556,787 DOC316.53.01102

More information