1 ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15

2 ir Cooled Scroll Chiller

3 ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum controller combinations type Digital Fixed no. 1 MGB-F25W/RN1 Double pipe MGB-D25W/RN1 Double pipe MGB-F30W/RN1 Double pipe MGB-D30W/RN1 Double pipe MGCSL-F30W/RN1 Double pipe MGCSL-D30W/RN1 Double pipe MGCL-F30W/RN1 Double pipe MGCL-D30W/RN1 Double pipe MGB-F55W/RN1 Shell and tube MGB-F60W/RN1 Shell and tube MGB-F65W/RN1 Shell and tube MGB-D65W/RN1 Shell and tube MGBL-F65W/RN1 Shell and tube MGBL-D65W/RN1 Shell and tube MGB-F130W/RN1 Shell and tube MGBL-F130W/RN1 Shell and tube MGB-F200W/RN1 Shell and tube MGBL-F200W/RN1 Shell and tube MGBT-F250W/RN1 Shell and tube MGBL-F250W/RN1 Shell and tube Maximum capacity( ) Wired controller 25/30 module 30 module (integrated) 55/60/65 module 130 module 200 module 250 module Page 3

4 ir Cooled Scroll Chiller - Specifications Capacity Heating Capacity Power input Power supply Power supply EER COP Compressor Refrigerant rated current Heating Heating rated current Manual switch Fuse Model Brand Model Quantity Refrigerant oil Refrigerant control Weight Number of rows V/Ph/Hz / / Pieces ml Fan motor model Condenser (ir side) Quantity of fan motor Pieces ir flow 10³m³/h Fan motor rated current Fan motor input Water pressure drop kpa Volume L Evaporator (Water side) Water inlet/outlet pipeline inside normal diameter mm Water flow volume m³/h Max. design pressure MPa Water pipe connection type Dimension Net (W H D) mm Packing (W H D) mm Weight Connection wiring Net weight Power wire kg mm² Operation weight Signal wire kg mm² Control type Noise level db() kg MGB-F25W/RN1 MGB-D25W/RN1 MGB-F30W/RN1 MGB-D30W/RN /3/ /3/ /3/ /3/ Scroll (fixed speed) Scroll (digital+fixed speed) Scroll (fixed speed) Scroll (digital+fixed speed) Copeland Copeland Copeland Copeland ZP67KCE-TFD-522 ZPD67KCE-TFD-532/ ZP67KCE-TFD-522 ZP67KCE-TFD-522 ZPD67KCE-TFD-532/ ZP67KCE-TFD /1 2 1/ / /1656 R410 R410 R410 R410 EXV EXV EXV EXV Fin-coil Fin-coil Fin-coil Fin-coil YDK400-8-Y YDK400-8-Y YDK400-8-Y YDK400-8-Y Double-pipe Double-pipe Double-pipe Double-pipe DN40 DN40 DN40 DN Flexible joint Flexible joint Flexible joint Flexible joint core with shielding core with shielding core with shielding core with shielding Wired controller Wired controller Wired controller Wired controller Safety protection device Operation water temp mbient temp C C 1) Protection for over-high discharge pressure. 7) Protection for compressor overload. 2) Protection for over-low suction pressure. 8) Outlet and inlet water temperature difference protection. 3) Power supply phase sequence protection. 9) Compressor discharge temperature protection. 4) nti-freezing protection in cooling mode. 10) Water flow cut-off protection. 5) nti-freezing protection in Winter. 11) Sensor malfunction protection. 6) Protection for compressor over current. 12) Low-temperature protection of shell and tube heat exchanger Heating Heating Note: Specifications are based on the following conditions: : chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. Heating : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 CDB/6 CWB. Water side fouling factor: 0.086m2 C/. 1m away in open field(sound pressure). Page 4

5 ir Cooled Scroll Chiller - Specifications Capacity Heating Capacity Power input Power supply Power supply EER COP Compressor rated current Heating Heating rated current Manual switch Fuse Quantity V/Ph/Hz / / Pieces Refrigerant oil ml Refrigerant Refrigerant control Weight kg Number of rows Fan motor model Condenser (ir side) Quantity of fan motor Pieces ir flow 10³m³/h Fan motor rated current Fan motor input Water pressure drop kpa Volume L Evaporator (Water side) Water inlet/outlet pipeline inside normal diameter mm Water flow volume m³/h Max. design pressure MPa Dimension Weight Connection wiring Control type Noise level Safety protection device Model Brand Model Water pipe connection type Net (W H D) Packing (W H D) Net weight Operation weight Power wire Signal wire mm mm kg kg mm² mm² db() MGCSL-F30W/RN1 MGCSL-D30W/RN1 MGCL-F30W/RN1 MGCL-D30W/RN (Pump) (Pump) (Pump) (Pump) /3/ /3/ /3/ /3/ Scroll (fixed speed) Scroll (digital+fixed speed) Scroll (fixed speed) Scroll (digital+fixed speed) Copeland Copeland Copeland Copeland ZP67KCE-TFD-522 ZPD67KCE-TFD-532/ ZP67KCE-TFD-522 ZP67KCE-TFD-522 ZPD67KCE-TFD-532/ ZP67KCE-TFD /1 2 1/ / /1656 R410 R410 R410 R410 EXV EXV EXV EXV Fin-coil Fin-coil Fin-coil Fin-coil YDK550-6E YDK550-6E YDK550-6E YDK550-6E Double-pipe Double-pipe Double-pipe Double-pipe / / DN40 DN40 DN40 DN Flexible joint Flexible joint Flexible joint Flexible joint core with shielding core with shielding core with shielding core with shielding Wired controller Wired controller Wired controller Wired controller ) Protection for over-high discharge pressure. 8) Outlet and inlet water temperature difference protection. 2) Protection for over-low suction pressure. 9) Compressor discharge temperature protection. 3) Power supply phase sequence protection. 10) Water flow cut-off protection. 4) nti-freezing protection in cooling mode. 11) Sensor malfunction protection. 5) nti-freezing protection in Winter. 12) Low ambient temperature drive-up protection 6) Protection for compressor over current. 13) Low temperature protection of shell and tube heat exchanger. 7) Protection for compressor overload. Operation water temp mbient temp C C 0 17(Less than 5 C must add antifreeze) Heating Heating Note: Specifications are based on the following conditions: : chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. Heating : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 CDB/6 CWB. Water side fouling factor: 0.086m2 C/. 1m away in open field(sound pressure). Page 5

6 ir Cooled Scroll Chiller - Specifications Capacity Heating Capacity Power input Power supply Power supply EER COP Compressor rated current Heating Heating rated current Manual switch Fuse Model Brand Model V/Ph/Hz / / Quantity Pieces Refrigerant oil ml Refrigerant Refrigerant control Weight kg Number of rows Fan motor model Condenser (ir side) Quantity of fan motor Pieces ir flow 10³m³/h Fan motor rated current Fan motor input Water pressure drop kpa Volume L Evaporator (Water side) Water inlet/outlet pipeline inside normal diameter mm Water flow volume m³/h Max. design pressure MPa Water pipe connection type Dimension Net (W H D) mm Packing (W H D) mm Weight Net weight kg Operation weight kg Connection wiring Power wire mm² Signal wire mm² Control type Noise level db() MGB-F60W/RN1 MGB-F65W/RN1 MGB-D65W/RN /3/ /3/ /3/ /3/ Scroll (fixed speed) Scroll (fixed speed) Scroll (fixed speed) Scroll (fixed speed+digital) Danfoss Danfoss Danfoss Copeland SH1404LC SH1404LC SH1404LC ZP144KCE-TFD-522 / ZPD72KCE -TFD-433 / ZP67KCE-TFD /1893/1685 R410 R410 R410 R410 EXV+ capillary EXV+ capillary EXV+ capillary EXV+ capillary Fin-coil Fin-coil Fin-coil Fin-coil YDK550-6D YDK550-6D YDK550-6D YDK550-6E Shell-tube Shell-tube Shell-tube Shell-tube DN100 DN100 DN100 DN Flexible joint Flexible joint Flexible joint Flexible joint core with shielding core with shielding core with shielding core with shielding Wired controller Wired controller Wired controller Wired controller Safety protection device 1) Protection for over-high discharge pressure. 7) Protection for compressor overload. 2) Protection for over-low suction pressure. 8) Outlet and inlet water temperature difference protection. 3) Power supply phase sequence protection. 9) Compressor discharge temperature protection. 4) nti-freezing protection in cooling mode. 10) Water flow cut-off protection. 5) nti-freezing protection in Winter. 11) Sensor malfunction protection. 6) Protection for compressor over current. 12) Low-temperature protection of shell and tube heat exchanger. Operation water temp mbient temp C C 5 17 Heating Heating (Less than 5 C must add antifreeze) Heating Note: Specifications are based on the following conditions: : chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. Heating : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 CDB/6 CWB. Water side fouling factor: 0.086m2 C/. 1m away in open field(sound pressure). Page 6

7 ir Cooled Scroll Chiller - Specifications Model MGBL-F65W/RN1 MGBL-D65W/RN1 MGB-F130W/RN1 MGBL-F130W/RN1 Capacity Heating Capacity Power input rated current Heating Heating rated current Power supply V/Ph/Hz /3/ /3/ /3/ /3/50 Power supply Manual switch Fuse EER / COP / Scroll (fixed speed) Scroll (fixed speed+digital) Scroll (fixed speed) Scroll (fixed speed) Brand Danfoss Copeland Danfoss Danfoss Compressor Model SH1404LC ZP144KCE-TFD-522 / ZPD72KCE -TFD-433 / ZP67KCE-TFD-420 SH1404LC SH1404LC Quantity Pieces Refrigerant oil ml Refrigerant Refrigerant control Weight kg Number of rows Fan motor model Condenser (ir side) Quantity of fan motor Pieces ir flow 10³m³/h Fan motor rated current Fan motor input Water pressure drop kpa Volume L Evaporator (Water side) Water inlet/outlet pipeline inside normal diameter mm Water flow volume m³/h Max. design pressure MPa Water pipe connection type /1893/ R410 R410 R410 R410 EXV+ capillary EXV+ capillary EXV+ capillary EXV+ capillary Fin-coil Fin-coil Fin-coil Fin-coil YDK550-6E YDK550-6E YDK550-6D YDK550-6E Shell-tube Shell-tube Shell-tube Shell-tube DN100 DN100 DN65 DN Flexible joint Flexible joint Flexible joint Flexible joint Dimension Net (W H D) Packing (W H D) mm mm Weight Connection wiring Net weight Operation weight Power wire Signal wire kg kg mm² mm² core with shielding core with shielding core with shielding core with shielding Control type Wired controller Wired controller Wired controller Wired controller Noise level db() ) Protection for over-high discharge pressure. 7) Protection for compressor overload. 2) Protection for over-low suction pressure. 8) Outlet and inlet water temperature difference protection. Safety protection device 3) Power supply phase sequence protection. 9) Compressor discharge temperature protection. 4) nti-freezing protection in cooling mode. 10) Water flow cut-off protection. 5) nti-freezing protection in Winter. 11) Sensor malfunction protection. 6) Protection for compressor over current. 12) Low-temperature protection of shell and tube heat exchanger. Operation water temp C 0 17(Less than 5 C must add antifreeze) Heating Heating (Less than 5 C must add antifreeze) Heating mbient temp C Heating Heating Heating Note: Specifications are based on the following conditions: : chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. Heating : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 C DB/6 C WB. Water side fouling factor: 0.086m2 C/. 1m away in open field (sound pressure). Page 7

8 ir Cooled Scroll Chiller - Specifications Model MGB-F200W/RN1 MGBL-F200W/RN1 MGBT-F250W/RN1 MGBL-F250W/RN1 Capacity Heating Capacity Power input Power supply Power supply EER COP rated current Heating Heating rated current Manual switch Fuse V/Ph/Hz / / /3/ /3/ /3/ /3/ Scroll (fixed speed) Scroll (fixed speed) Scroll (fixed speed) Scroll (fixed speed) Brand Danfoss Danfoss Danfoss Danfoss Compressor Model SH1404LC SH1404LC SH1204LC SH1204LC Quantity Pieces Refrigerant oil ml Refrigerant Refrigerant control Weight kg Number of rows Fan motor model Condenser (ir side) Quantity of fan motor Pieces ir flow 10³m³/h Fan motor rated current Fan motor input Water pressure drop kpa Volume L Evaporator (Water side) Water inlet/outlet pipeline inside normal diameter mm Water flow volume m³/h Max. design pressure MPa Water pipe connection type Dimension Net (W H D) mm Packing (W H D) mm Weight Net weight kg Operation weight kg Connection wiring Power wire mm² Control type Signal wire mm² Noise level db() Safety protection device R410 R410 R410 R410 EXV+ capillary EXV+ capillary EXV+ capillary EXV+ capillary Fin-coil Fin-coil Fin-coil Fin-coil YDK550-6D YDK550-6E YS700-6F-1/YS700-6F-2 YDK550-6E 6 6 6/ Shell-tube Shell-tube Shell-tube Shell-tube DN80 DN80 DN100 DN Flexible joint Flexible joint Flexible joint Flexible joint core with shielding core with shielding core with shielding core with shielding Wired controller Wired controller Wired controller Wired controller ) Protection for over-high discharge pressure. 7) Protection for compressor overload. 2) Protection for over-low suction pressure. 8) Outlet and inlet water temperature difference protection. 3) Power supply phase sequence protection. 9) Compressor discharge temperature protection. 4) nti-freezing protection in cooling mode. 10) Water flow cut-off protection. 5) nti-freezing protection in Winter. 11) Sensor malfunction protection. 6) Protection for compressor over current. 12) Low-temperature protection of shell and tube heat exchanger. Operation water temp mbient temp C C 5 17 Heating Heating (Less than 5 C must add antifreeze) Heating Heating Heating Heating Note: Specifications are based on the following conditions: : chilled water inlet/outlet: 12 C / 7 C, and outdoor ambient temp. of 35 C DB. Heating : warm water inlet/outlet: 40 C / 45 C, and outdoor ambient temp. 7 CDB/6 CWB. Water side fouling factor: 0.086m2 C/. 1m away in open field(sound pressure). Page 8

9 ir Cooled Scroll Chiller - Features Modular design Design flexibility. Back-up function. Master controller oversees operation of all connected modules. Low starting current. Max 8 modules Digital scroll technology Digital scroll technology, provides maximum reliability, high efficiency and quiet operation. dvanced digital scroll technology for small modules (25/30/65) maximizes reliability, ensures efficient and silent operation, optimizes capacity output, and provides a comfortable room temperature. 1 Loaded 2S 2S 5S 5S 0 Unloaded 8S 10S cycle 8S 5S 5S 10S cycle 10S cycle 10S cycle 20% output 50% output Page 9

10 ir Cooled Scroll Chiller - Features Wide range of ambient temperature The ambient temperature can go down to - 10 C in cooling mode. The wide ambient temperature range is optional, and can be modified to meet requirements. Mode mbient temp. Heating Normally(S8 address OFF) * Low temp. (S8 address ON) 10~46 C -10~46 C -10~21 C User friendly remote control Switch the S7 address on the PCB to ON to enable the following remote control operations: Remote ON/OFF. Remote mode selection: heating or cooling. Remote alarm. Note: When using the remote control function, the wired controller will be invalid. Backup functions Master Master Slave Slave When unit fails. If master unit fails, all the units will stop. If one slave unit fails, this unit will stop but the others will keep running. When the master unit fails, any of the slave one can be set as the master unit by manual setting. When unit is under protection. If master unit s protection occurs, this unit will stop but the others will keep running. If slave unit s protection occurs, this unit will stop but the others will keep running. (Except PE, P9 protection happens) PE: Low-temperature protection of evaporator. P9: Outlet and inlet water temperature difference protection. Page 10

11 ir Cooled Scroll Chiller - Features Optimized electrical design The electrical panels provide a clear visual representation of the wiring scheme completed during assembly. Built-in hydraulic module The unit's in-built hydraulic module simplifies installation, saves space, improves aesthetics, and cuts costs. (vailable for MGCSL-F(D)30W/RN1.) uto-air exchanse valve Fan coil unit Fan coil unit 2-way valve Water pump Expansion tank Y-shaped filiter Water-flow valve Water replenishing valve 1.5kg<water replenishing pres<6kg Flexible joint 2-way valve Fan coil unit Double-pipe heat exchanger Safety valve Flexible joint Flexible joint Thermometer Cutoff valve Manometer Flexible joint Fan coil unit ux. heater This figure for reference purpose only, please in terms of the design rule for field installation. Page 11

12 ir Cooled Scroll Chiller - pplication range Operation temperature range Outdoor air temperature range 10 C HETING RNGE -10 C -10 C 21 C COOLING RNGE COOLING RNGE 46 C 46 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Water outlet temperature range COOLING HETING 5 C 17 C 45 C 50 C COOLING 22 C HETING 50 C 0 C 17 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C ModelV ModeOutdoor air temperature range Heating Outdoor Water outlet ambient temperature range range 10 C~46 C -10 C~46 C -10 C~21 C pplication Water outlet for module temperature range 0 C~17 C (7 C is default, less than 5 C must add antifreeze) 5 C~17 C (7 C is default) 22 C ~ 50 C (45 C is default) Water pressure drop Pressure drop (kpa) water pressure drop Pressure drop (kpa) water pressure drop Water flow(m³/h) Water flow(m³/h) Pressure drop (kpa) water pressure drop Pressure drop (kpa) water pressure drop Pressure drop (kpa) water pressure drop Water flow(m³/h) Pressure drop (kpa) Water flow(m³/h) 130 water pressure drop Pressure drop (kpa) Water flow(m³/h) 200 water pressure drop Pressure drop (kpa) Water flow(m³/h) 250 water pressure drop Water flow(m³/h) Water flow(m³/h) Page 12

13 ir Cooled Scroll Chiller - Glycol factors Ethylene glycol: Modification coefficient Quality of glycol% Freezing capacity Power Water Water flow point C modification modification resistance modification Propylene glycol: Quality of glycol% capacity modification Modification coefficient Power modification Water resistance Water flow modification Freezing point C Fouling factor Fouling Factor LTITUDE (m) Difference of water inlet and outlet temp ( C) 0.018m 2 C / 0.044m 2 C / 0.086m 2 C / 0.172m 2 C / C P C P C P C P Sea level C-- capacity P--Power Page 13

14 ir Cooled Scroll Chiller - Performance data - Chilled water outlet temp mbient temp ( C) Model Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( C) Note: The inlet/outlet water temperature difference is 5 C. Page 14

15 ir Cooled Scroll Chiller - Performance data - Chilled water mbient temp ( C) outlet temp. Model Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( C) Note: The inlet/outlet water temperature difference is 5 C. Page 15

16 ir Cooled Scroll Chiller - Performance data - Chilled water mbient temp ( C) outlet temp. Model Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( C) Note: The inlet/outlet water temperature difference is 5. ir Cooled Scroll Chiller - Performance data - Heating Hot water outlet temp Model mbient temp ( C) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( C) Note: The inlet/outlet water temperature difference is 5 C. Page 16

17 Page 17 ir Cooled Scroll Chiller - Performance data - Heating Hot water outlet temp Model mbient temp ( C) Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power ( ) C O Note: The inlet/outlet water temperature difference is 5 C.

18 ir Cooled Scroll Chiller - Performance data - Heating O mbient temp ( Hot water C) outlet temp Model Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power Capacity Power O ( C) ir Cooled Scroll Chiller - Electrical data Model Outdoor Unit Power Supply Compressor OFM Hz Voltage Min. Max. TOC MF LR(each) RL(each) KW FL MGB-F25W/RN MGB-D25W/RN / MGB-F30W/RN MGB-D30W/RN / MGCSL-F30W/RN MGCSL-D30W/RN / MGCL-F30W/RN MGCL-D30W/RN / MGB-F55W/RN ( 2) 4.0( 2) MGB-F60W/RN ( 2) 4.0( 2) MGB-F65W/RN ( 2) 4.0( 2) MGB-D65W/RN /82.4/ /12.7/ ( 2) 4.0( 2) MGBL-F65W/RN ( 2) 4.0( 2) MGBL-D65W/RN /82.4/ /12.7/ ( 2) 4.0( 2) MGB-F130W/RN ( 4) 4.0( 4) MGBL-F130W/RN ( 4) 4.0( 4) MGB-F200W/RN ( 6) 4.0( 6) MGBL-F200W/RN ( 6) 4.0( 6) MGBT-F250W/RN ( 8) 1.8( 8) MGBL-F250W/RN ( 8) 3.7( 8) Remark: TOC: Total Over-current mps. () MF: Max. Fuse mps. () LR: Locked Rotor mps. () RL: Rated Load mps. () OFM: Outdoor Fan Motor. KW: Rated Motor Input () FL: Full Load mps. Page 18

19 ir Cooled Scroll Chiller - Dimensions 55/60/65 module Model Unit B C D E F G H I J K MGB-F55W/RN1 D E C MGB-F60W/RN1 MGB-F65W/RN1 MGB-D65W/RN1 MGBL-F65W/RN1 MGBL-D65W/RN1 mm inch H 2 1 Top cover 1 2 ir outlet F G 3 ir inlet 4 Water outlet 5 Compressor Front view 6 Electric control box I J 7 Water inlet K 3 7 B Top view 130 module D E C F B Front view Side view CC 05/15 Page 19

20 ir Cooled Scroll Chiller - Dimensions 25/30 module Model Unit B C D E F C MGB-F(D)25W/RN1 MGB-F(D)30W/RN1 MGBL-F(D)30W/RN1 mm inch F E 2 D Front view 3 1 B 3 1 Top cover 2 ir outlet 3 ir inlet 4 Water outlet 5 Water inlet 6 Electric control box Top view module (Integrated) (vailable for MGCSL-F30W/RN1 and MGCSL-D30W/RN1) Front view 1 Left view 2 1 ir inlet 2 ir outlet Water inlet 4 Make up water inlet 5 Water outlet Top view Drain Page 20

21 ir Cooled Scroll Chiller - Dimensions G B Top view Installation hole Model Unit B C D E F G H MGB-F130W/RN1 mm MGBL-F130W/RN1 inch module F C H Hole for Installation boltφ15 1 Top cover 1 ir outlet ir outlet 2 Condenser 3 Compressor 4 Evaporator 5 Electric control box ir inlet ir inlet 8 6 Water outlet 7 Water inlet Compressor D E Front view B Left view Model Unit B C D E F G H MGB-F200W/RN1 Mm MGBL-F200W/RN1 inch Page 21

22 ir Cooled Scroll Chiller - Dimensions H ir outlet ir outlet 1 1.Top cover 2.Compressor G ir inlet ir inlet ir inlet ir inlet 7 3.Evaporator 4.Water outlet 5.Electric control box Hole for Installation bolt 15 6.Water inlet 7.Condenser Installation hole module F C D E B Front view Left view ir outlet H H ir outlet ir outlet 1 ir outlet G Hole for Installation bolt 15 Bottom view Installation hole ir inlet 2 ir inlet ir inlet 8 ir inlet 3 ir inlet Top cover 2.Compressor 3.Evaporator 4.Water outlet 5.Electric control box 6.Water inlet 7.Condenser 8.Transportation guard plate (Be removed off after installation) Model Unit B C D E F G H MGBT-F250W/RN1 Mm MGBL-F250W/RN1 inch Page 22

23 ir Cooled Screw Chiller Page 23

24 ir Cooled Screw Chiller - Product line LSBLGW380C LSBLGW500C LSBLGW600C LSBLGW720C LSBLGW900C LSBLGW1000C LSBLGW1200C LSBLGW1420C Page 24

25 ir Cooled Screw Chiller - Features and benefits Environmental responsibility more efficient chiller means less electricity generation, which reduces greenhouse gas (CO²) emissions. R134a friendly refrigerant has no ozone-depletion potential. Helps You chieve LEED Certification. Less refrigerant charge. High efficiency. R134a Operating cost savings Better IPLV: Follows HRI 550/590 calculation that notes the 99% of operating hours are not at full load. The COP was designed to be the best on the 50% ~ 75% part load conditions. Larger T of cooler reducing HVC system running cost. EER COP /Ton nnual Hours(%) Lowest total cost of ownership Chiller Load(%) Reliability low risk of downtime. Recognized component partner: Bitzer Comp. & Danfoss EXV, Shneider electric. -0 World-class testing facilities Each unit was extensively tested to verify that their operation is robust and that a smooth start-up is ensured. Low maintenance costs. Page 25

26 ir Cooled Screw Chiller - Specifications LSBLGWXXX/C capacity Power input COP / Semi-hermetic screw compressor Circuit Quantity Circuit B Quantity Oil recharge BSE170 BSE170 BSE170 BSE170 BSE170 BSE170 BSE170 BSE17 Circuit L Circuit B L Refrigerant R134a R134a R134a R134a R134a R134a R134a R134a Circuit kg Circuit B kg Control type EXV EXV EXV EXV EXV EXV EXV EXV Evaporator Shell and tube heat exchanger(dx) Water content L Water flow m³/h Pressure drop kpa Max. design pressure MPa Pipe connection type Victaulic coupling Water inlet/outlet pipe dim. mm Condenser Fin-coil Fin-coil Fin-coil Fin-coil Fin-coil Fin-coil Fin-coil Fin-co Fan Quantity Total air flow m³/h 23000* * * * * * * *2 Fan speed rpm Unit length mm Unit width mm Unit height mm Shipping weight kg Running weight kg Safety protection device The following safety devices are equipped as standard: High pressure protection Low pressure protection Compressor overload protection Fans overload protection High discharge temp. protection Power failure protection Contractor protection Water flow protection Motor protection Low oil level protection Differential pressure protection Notes: Nominal cooling capacities are based on the following conditions: Chilled water inlet/outlet temp: 12 C/7 C; Outdoor temp (DB/WB): 35 C/24 C Evaporator fouling factor = m2 C/ The applicable ambient temperature range of R134a air-cooled screw units is 15 C-43 C Noise Preventer While running,the operator should wear the noise preventer Page 26

27 ir Cooled Screw Chiller - Performance Data mbient Temperature/ Model Outlet Temp. / C Capacity / Power Input / Capacity / Power Input / Capacity / Power Input / Capacity / Power Input / Capacity / Power Input / Capacity / Power Input / Capacity / Power Input / LSBLGW380/C LSBLGW500/C LSBLGW600/C LSBLGW720/C Note: The inlet/outlet water temperature difference is 5C. Page 27

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Report on thermal cooling system implementation and performance

Report on thermal cooling system implementation and performance SUSTAINABLE ENERGY SYSTEMS Report on thermal cooling system implementation and performance Organisation name of lead contractor for this deliverable: ATC POLYCITY DD 2C.1 TREN/05FP6EN/S07.43964/513481

More information

Free Cooling Technology

Free Cooling Technology Free Technology Utilise low ambient temperatures to save energy and reduce your cooling costs by up to 70% Free for industrial process and air conditioning How Free can save you money Free is a fast and

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

HITACHI Modular Chiller Solutions

HITACHI Modular Chiller Solutions Cooling Capacity 95kW - 1920kW Heating Capacity 92kW - 2384kW HITACHI Modular Chiller Solutions Giving you complete control The benefits of our unique modular design Projects change and develop over time.

More information

Flooded Type Water-Cooled Chillers. R134a

Flooded Type Water-Cooled Chillers. R134a Flooded Type WaterCooled Chillers The HighEfficiency WaterCooled Flooded Chillers The New WaterCooled Flooded chiller with improved efficiency and functionality by incorporating several advanced technology

More information

Air Conditioners. Technical Data. Pair application EEDEN RXS-J

Air Conditioners. Technical Data. Pair application EEDEN RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

Heating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3

Heating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3 Heating Technical Data Daikin Altherma hybrid heat pump EEDEN14-729 EVLQ-CV3 Outdoor Unit EVLQ-CV3 TABLE OF CONTENTS EVLQ-CV3 1 Features............................................................. 2

More information

IT COOLING CHILLERS. NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE kw, SCROLL COMPRESSORS AND R410A

IT COOLING CHILLERS. NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE kw, SCROLL COMPRESSORS AND R410A IT COOLING CHILLERS / NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE 39-795 kw, SCROLL COMPRESSORS AND R410A IT COOLING CHILLERS / THE KEY SOLUTION FOR YOUR DATA CENTER

More information

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems Energieeffizient, Energy efficient, kompakt compact, und and variantenreich versatile GLAC0524- - 1204BD2 Luftgekühlte Air cooled Kaltwassererzeuger Chiller Data Daten && Facts Fakten Lufttechnik GEA Heat

More information

RHA TECNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RHA TECNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G A-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RHA C TECNICAL MANUAL 1 2 TABLE OF CONTENTS THIS MANUAL IS DIVIDED INTO SECTIONS. THE NAMES APPEAR IN THE

More information

Rooftops High performance, proven reliability and easy installation

Rooftops High performance, proven reliability and easy installation Rooftops High performance, proven reliability and easy installation 1 Airfinity Rooftops Comfort and economy When it comes to installing and maintaining an HVAC system, every cent counts. From your initial

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-GV Outdoor Unit RX-GV TABLE OF CONTENTS RX-GV Features............................................................. 2 2 Specifications.......................................................

More information

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that. Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany Universal cooler in individual design BASELINE BL 006 BL 1440 Customized refrigeration technology Made in Germany 2 Lahntechnik your system partner for customized refrigeration technology For more than

More information

Technical Report No Rev. 00 Dated

Technical Report No Rev. 00 Dated Client: Manufacturing place: Test subject: Name: ENERGON HELLAS G.N. KYTINOS & SIA O.E. Address: Arethousis 44, 34100 Halkida, GREECE Manufacturer s name: ENERGON HELLAS G.N. KYTINOS & SIA O.E. Address:

More information

HIGH EFFICIENCY SHOWERS WASTE WATER HEAT RECOVERY UNIT. Saved power 80kW. Showers waste water 9 C Power consumption 3,1kW. Showers waste water 31 C

HIGH EFFICIENCY SHOWERS WASTE WATER HEAT RECOVERY UNIT. Saved power 80kW. Showers waste water 9 C Power consumption 3,1kW. Showers waste water 31 C Shower HIGH EFFICIENCY SHOWERS WASTE WATER HEAT RECOVERY UNIT Calculation of savings (for illustrative purposes) Note: power rates refer to a medium capacity of 3m 3 /h Costs and savings are calculated

More information

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18.

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18. ENVIRONMENTALLY SOUND REFRIGERANT H4A3 Product Specifications EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 3 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 3 phase, 60 Hz

More information

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling

More information

Sullair Water Chillers. Precision Chilled Water

Sullair Water Chillers. Precision Chilled Water Sullair Water Chillers Precision Chilled Water Sullair Water Chillers What are Water Chillers? Why Choose a Sullair Water Chiller? Water chillers are used for controlled cooling of products, mechanisms

More information

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN. Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems

More information

MINNESOTA STATE SECTION ADVERTISEMENT FOR BIDS

MINNESOTA STATE SECTION ADVERTISEMENT FOR BIDS MINNESOTA STATE SECTION 00 11 13 ADVERTISEMENT FOR BIDS Sealed Bids for: will be received by: Ridgewater College Commercial Chiller Purchase Ridgewater College Willmar Campus 2101 15 th Ave. N.W Willmar,

More information

Integrated Air Conditioning System

Integrated Air Conditioning System Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability

More information

SIMPLICITY OR INTELLIGENCE? Heat pumps and water-cooled chillers Cooling capacity kw Heating capacity kw 30WG / 61WG / 30WGA

SIMPLICITY OR INTELLIGENCE? Heat pumps and water-cooled chillers Cooling capacity kw Heating capacity kw 30WG / 61WG / 30WGA EW ATION D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING AND HEATING SOLUTIONS SIMPLICITY OR INTELLIGENCE? AQUASNAP, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Heat pumps and water-cooled

More information

Air Conditioning. Technical Data EEDEN RXS-L

Air Conditioning. Technical Data EEDEN RXS-L Air Conditioning Technical Data EEDEN15-100 RXS-L TABLE OF CONTENTS RXS-L 1 Features............................................................. 2 2 Specifications.......................................................

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard

More information

technical data air conditioning systems RKS-F2V1B Split Sky Air

technical data air conditioning systems RKS-F2V1B Split Sky Air technical data RKS-F2VB air conditioning systems Split Sky Air Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3 MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model

More information

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3 MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 18,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 18,000 BTUH Multiaqua Model

More information

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3 MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 12,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 12,000 BTUH Multiaqua Model

More information

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25AGB-W AUG25ALD-W AUG25RLD-W AUY25AGB-W AUY25ALD-W AUY25RLD-W AUT25ALD-W AUT25RLD-W AUG30AGB-W AUG30ALD-W AUG30RLD-W

More information

LG Renewable Heating Solutions

LG Renewable Heating Solutions RENEWABLE > SHIFT AWAY FROM FOSSIL FUELS LG Renewable Heating Solutions Products in this brochure contain fluorinated greenhouse gases (R410A) and (R134a) LG Air Conditioning and Energy Solutions UK Energy

More information

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group Coercial Air Conditioners 2016 Coercial Air Conditioner Division Midea Group VRF V4+K Series 50Hz Midea CAC After-service Application Midea CAC News Application Add.: West Region of Midea Coercial Air

More information

technical data air conditioning systems Outdoor Units RKS-F3V1B RKS-FAV1B

technical data air conditioning systems Outdoor Units RKS-F3V1B RKS-FAV1B technical data Outdoor Units RKS-F3V1B RKS-FAV1B air conditioning systems technical data Outdoor Units RKS-F3V1B RKS-FAV1B air conditioning systems Outdoor Units R-410A RKS-F3V1B_RKS-FAV1B TABLE OF CONTENTS

More information

APPLICATION GUIDE Jan 2002

APPLICATION GUIDE Jan 2002 APPLICATION GUIDE Jan 2002 CONTENTS < Introduction and description of the component... 2 < Standard Performance tables... 10 Technical data... 22 Electrical data... 24 Dimensional data... 25 < Standard

More information

EPCE00-11A. Powerful. water cooled. Hydronic systems EUW*40-200KX

EPCE00-11A. Powerful. water cooled. Hydronic systems EUW*40-200KX EPCE00-11A Powerful water cooled Hydronic systems EUW*40-200KX DAIKIN Daikin enjoys a worldwide reputation, based on over 70 years' experience in the manufacture of advanced, high quality air conditioning

More information

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being ANK Please fill out the requested information Aermec adheres to the EUROVENT Certification Programme: LCP/A/P/R The products concerned appear in the EUROVENT web site www. eurovent-certification. com ANK

More information

VRF 50/60Hz V5 E Series

VRF 50/60Hz V5 E Series 1702-1V1701 VRF 50/60Hz V5 E Series Coercial Air Conditioners 2017/2018 VRF 50/60Hz V5 E Series Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde,

More information

Water chiller / Heat pump. Aquaciat Power. Sustainable power NA D

Water chiller / Heat pump. Aquaciat Power. Sustainable power NA D Water chiller / Heat pump Aquaciat Power Sustainable power u n i v e r s a l c o m f o r t NA 07.40 D Aquaciat power When Ciat brings together Discover Aquaciat Power, a range that combines the best technology

More information

Installation Instructions

Installation Instructions Installation Instructions AquaSnap 010-055 Chilled Water Storage Tank 50/60 Hz Part No: -900---001; -900---009; -900---010 CONTENTS INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................

More information

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling

More information

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor Technical Bulletin BT16N008GB-04 ELFOSpace WALL Water terminal unit for indoor installation, wall-mounted CFW 00.0 021.0 RANGE DC Brushless Motor High standards of efficiency and low noise New design Electronic

More information

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics Condensers & dry coolers ODIN Excellent energy yield & sound characteristics O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................. 2 Eurovent.......................................

More information

Sound HVAC Choices for Sustainable Design. Julian de Bullet

Sound HVAC Choices for Sustainable Design. Julian de Bullet PLEASE MUTE CELL PHONES Sound HVAC Choices for Sustainable Design Julian de Bullet Director of Industry Relations McQuay International ASHRAE Distinguished Lecturer 703-395-5054 1 2 Rising?? What Is Sustainability?

More information

Split. Air Conditioning Technical Data RXM-M9

Split. Air Conditioning Technical Data RXM-M9 Split Air Conditioning Technical Data RXM-M9 TABLE OF CONTENTS RXM-M9 1 Features............................................................. 2 2 Specifications.......................................................

More information

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012 Product Catalog Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz June 2012 SSP-PRC027-EN General Data Table 1. General Data 7½ - 20 Ton Condensing Units 60 Hz 7½ Tons 10 Tons 15 Tons

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende Air Conditioners Technical Data Technical Data O u t d o o r u n i t - P a i r a p p l i c a t i o n T E C H N I C A L DATA - O U T D O O R U N I T - PA I R A P P L I C AT I O N O u t d o o r u n i t -

More information

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti.

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti. Water chillers and heat pumps MCW Indoor monobloc unit MCW - 39 kw Compact single circuit units Rotary compressor PLUS Scroll compressor R-0C R-0 C refrigerant Cooling only Cooling / Heating Ease of installation

More information

ANK REVERSIBLE HEAT PUMP EFFICIENCY, ENERGY SAVINGS & WELL-BEING

ANK REVERSIBLE HEAT PUMP EFFICIENCY, ENERGY SAVINGS & WELL-BEING ANK REVERSIBLE HEAT PUMP EFFICIENCY, ENERGY SAVINGS & WELL-BEING Air-cooled axial fans Scroll compressors R410A Cooling capacity 6,8-30,0kW Heating capacity 8,0-33,5kW ANK reversible heat pump all the

More information

Air-cooled Chillers with High Speed Centrifugal Compressors

Air-cooled Chillers with High Speed Centrifugal Compressors Air-cooled Chillers with High Speed Centrifugal Compressors Model -X 575-1600 kw Model -XP 720-1250 kw Model -XPG 450-1250 kw 1 Trane Sintesis excellent Air-cooled Chillers with High Speed Centrifugal

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Copeland TM s 0A and 507 Refrigerants 9 Hunt St - Pryor, OK 736-98.85.7 - Fax 800.6.539 - www.century-refrigeration.com Standard Features

More information

Trane Water-Source Variable Refrigerant Flow

Trane Water-Source Variable Refrigerant Flow Trane Water-Source Variable Refrigerant Flow Trane Water-Source Variable Refrigerant Flow Energy Efficiency Meets Expertise TRANE IS THE GLOBAL LEADER IN HVAC EQUIPMENT, SYSTEMS, AND SERVICES, PROVIDING

More information

Water-Cooled Screw Chillers and Water/Water Heat Pumps

Water-Cooled Screw Chillers and Water/Water Heat Pumps Water-Cooled Screw Chillers and Water/Water Heat Pumps Model RTWF (R134a) 940-1860 kw Model RTWF G (R1234ze) 735-1420 kw Model RTHF (R134a) 1120-3180 kw 1 Trane XStream Water-Cooled Chillers and Water/Water

More information

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS F. Asdrubali, G. Baldinelli, A. Presciutti, M. Caporali University of Perugia - Industrial Engineering Department, Via G. Duranti

More information

INVERTER ROOF TOP PACKAGE UNITS

INVERTER ROOF TOP PACKAGE UNITS INVERTER ROOF TOP PACKAGE UNITS SMART PACKAGE UNITS Delivering an extensive range, with capacities starting from 11kW up to 270kW, incorporating inverter technology throughout our roof top package units.

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS Inverter compressors, EC fans, double skin construction package units designed to suit your project requirements SMART PACKAGE UNITS Delivering an extensive range, with capacities

More information

YKN2open A R C 032 A B

YKN2open A R C 032 A B york air-conditioning products ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 17 kw up to 40 kw YKN2open Features High efficiency EER and COP Low noise level EC supply fan All configurations: Cooling

More information

Largo & Allegro. Air Compressors. Largo & Allegro

Largo & Allegro. Air Compressors. Largo & Allegro Largo & Allegro Air Compressors Largo 110-160 & Allegro 110-180 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer

More information

Water-Cooled Chillers and Heat Pumps with Leading Control Technology. High Efficiency Chillers for High Performance Buildings

Water-Cooled Chillers and Heat Pumps with Leading Control Technology. High Efficiency Chillers for High Performance Buildings Water-Cooled Chillers and Heat Pumps with Leading Control Technology High Efficiency Chillers for High Performance Buildings Raising Your HVAC Experience to Unmatched Levels of Performance, Comfort and

More information

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR)

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR) 01 Introduction TARGET POSITION FEATRE Multi Domestic EHS Mono/Split Low Temperature - Domestic, 50 water EHS High Temperature - Domestic, 80 water All-in-One More Efficient Free of Charge 50 or 80 Water

More information

SECTION ROTARY SCREW WATER CHILLERS

SECTION ROTARY SCREW WATER CHILLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

16LJ LJ-A Single-Effect Hot Water-Fired Absorption Chillers. product selection data. Complete range 80 to 4000 kw. HFC-refrigerant free

16LJ LJ-A Single-Effect Hot Water-Fired Absorption Chillers. product selection data. Complete range 80 to 4000 kw. HFC-refrigerant free product selection data Complete range 8 to 4 kw HFC-refrigerant free Hot water source from COP up to.78 Single-Effect Hot Water-Fired Absorption Chillers 16LJ1-3 16LJ-A11-82 Original document 16LJ1-3 16LJ-A11-82

More information

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI OPERATING INSTRUCTIONs ISTRUZIONI D USO MODE d EMPLOI EN IT FR Control panel for air to water Inverter heat pump Pannello di controllo per pompa di calore Inverter aria / acqua Panneau de contrôle pour

More information

Air-Cooled Screw Chillers RTAF-G kw. The best bundled in one. Our best.

Air-Cooled Screw Chillers RTAF-G kw. The best bundled in one. Our best. Air-Cooled Screw Chillers RTAF-G 320 1720 kw The best bundled in one. Our best. 1 The Future of F-Gases The fluorinated refrigerants phase-down, as defined in the new EU F-Gas Regulation, is a step-by-step

More information

Product Catalog. VRF Water Source Unit 6to48Tons VRF-PRC017A-EN. November 2014

Product Catalog. VRF Water Source Unit 6to48Tons VRF-PRC017A-EN. November 2014 Product Catalog VRF Water Source Unit 6to48Tons November 2014 VRF-PRC017A-EN Introduction System Features 1,2 Copyright Modules are hybrid systems, shipping as standard heat pump configuration, field convertible

More information

Reducing running costs, whilst benefiting the environment and the future

Reducing running costs, whilst benefiting the environment and the future Reducing running costs, whilst benefiting the environment and the future The Danfoss DHP-R produces heating and hot water using stored solar energy from the bedrock, surface ground, groundwater or exhaust

More information

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V Rollair Air Compressors ROLLAIR 150E-150-180-220 AND ROLLAIR 150V-180V-240V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial

More information

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

INDOOR UNITS FVXS25F FVXS35F FVXS50 F Cooling Only INDOOR UNITS FVXS25F FVXS35F FVXS50 F Capacity cooling min~nom~max kw 1.3~2.5~3.0 1.4~3.5~3.8 1.4~5.0~5.6 Power input cooling min~nom~max kw 0.300~0.570~0.920 0.300~1.020~1.250 0.310~1.220~1.880

More information

DIN EN , DIN EN , DIN EN , DIN EN

DIN EN , DIN EN , DIN EN , DIN EN Test Report issued under the responsibility of: TEST REORT EHA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat umps

More information

CO2 solutions February 2018

CO2 solutions February 2018 CO2 solutions 27-28 February 2018 Summary Overview of regulations Overview of Rivacold solution CO2 carbon dioxide CO2 Rivacold solution Case History 2 1. Overview of regulations Overview of regulations

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

WATER-TO-WATER HEAT PUMP - WATER CHILLER. Dynaciat Power. Smart equipment that boosts performance NA B

WATER-TO-WATER HEAT PUMP - WATER CHILLER. Dynaciat Power. Smart equipment that boosts performance NA B WATER-TO-WATER HEAT PUMP - WATER CHILLER Smart equipment that boosts performance U N I V E R S A L C O M F O R T NA 10.91 B MORE EFFICIENCY The name in unsurpassed comfort, superior performance, and energy

More information

1 History. 2 Line-up

1 History. 2 Line-up 1 History 2 Line-up 3 Why LG Absorption Chiller? 4 Features & Benefits High Energy Efficiency Reliability & Stability Convenience LG is leading the chiller market with long experience of manufacturing

More information

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models : ROOM AIR CONDITIONER AK SERIES (50Hz) Models : AKY9FBSSW AKY9UBSSW CONTENTS SPECIFICATIONS.......................... CIRCUIT DIAGRAM........................ MICROCOMPUTER CONTROL CIRCUIT...... DISASSEMBLY

More information

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units. Product Catalog Variable Refrigerant Flow (VRF) System Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH/4TVR0072 0192 4TVH/4TVR0216 0528 Single Unit Modules Multi-Unit Modules January 2016 VRF-PRC008C-EN

More information

WT Model Water-to-Water Heat Pump

WT Model Water-to-Water Heat Pump WT Model Water-to-Water Heat Pump 2 to 6 ton Enhanced WT Model includes wider range of voltages and optional double-wall load side heat exchanger to this two-stage, ultra-efficient unit for best-in-class

More information

Ductless Heat Pumps OTP Series

Ductless Heat Pumps OTP Series Ductless Heat Pumps OTP Series Ouellet... A source of comfort for over 50 years! Ouellet Canada is recognized as the undisputed North American leader in the design, manufacture, and distribution of electric

More information

Product Catalog Split System Air Conditioners Odyssey

Product Catalog Split System Air Conditioners Odyssey Product Catalog Split System Air Conditioners Odyssey R-22 Dry Charge CoolingCondenser 7.5, 10, 15 and 20 Tons 60 Hz July 2018 SS-PRC037J-EN Introduction Wide network availability Flexible applications

More information

FIELD TEST STUDY ON THE PERFORMANCE OF AIR SOURCE HEAT PUMP IN LOW TEMPERATURE IN BEIJING

FIELD TEST STUDY ON THE PERFORMANCE OF AIR SOURCE HEAT PUMP IN LOW TEMPERATURE IN BEIJING 27 - - 11 -- FIELD TEST STUDY ON THE PERFORMANCE OF AIR SOURCE HEAT PUMP IN LOW TEMPERATURE IN BEIJING W. Wang, associate professor, The Department of Building Environment and Facility Engineering, The

More information

MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti.

MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti. Air/water chillers and heat pumps MPE Outdoor packaged unit MPE - kw Efficiency under all operating conditions Rotary compressor Plus Scroll compressor R-0A R-0A refrigerant Cooling only Cooling / Heating

More information

MULTI SPLIT INVERTER SYSTEMS

MULTI SPLIT INVERTER SYSTEMS MULTI SPLIT INVERTER SYSTEMS Energy Saving For conventional air-conditioning unit, the compressor will be running at the maximum frequency all the time. This requires a lot of energy and subsequently,

More information

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 23 81 00 DECENTRALIZED HVAC EQUIPMENT A. The other Contract Documents complement the requirements of this section. The General requirements apply to the work

More information

Introduction to Geothermal Comfort Systems in INDIA

Introduction to Geothermal Comfort Systems in INDIA Introduction to Geothermal Comfort Systems in INDIA History Ancient earth sheltered homes 1912 Swiss Patent 1945 - First GSHP operating in North America in Indianapolis 1949 Canada s first GSHP installation

More information

QUATTRO PROZONE / QUATTRO PROZONE EA

QUATTRO PROZONE / QUATTRO PROZONE EA HEAVY COMMERCIAL & INDUSTRIAL LINE QUATTRO PROZONE / QUATTRO PROZONE EA AIR/WATER UNITS FOR ASSOCIATED SYSTEMS WITH FOUR PIPES Up to Class A Scroll compressors Axial fans Condensing coil fins Outdoor installation

More information

york yvwa variable-speed, water-cooled, screw chillers Infinite chiller configurations to help you achieve your goals

york yvwa variable-speed, water-cooled, screw chillers Infinite chiller configurations to help you achieve your goals york yvwa variable-speed, water-cooled, screw chillers Infinite chiller configurations to help you achieve your goals Efficiency Flexibility Sustainability Confidence YORK YVWA variable-speed, water-cooled,

More information

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ REFRIGERANT CONDENSERS Guide Specifications T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ September 5, 2012 Note: This Specification is for Allied Commercial T-Series 6- to 20-ton, outdoor air conditioner

More information

Fiberglass Cooling Towers

Fiberglass Cooling Towers Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality

More information

EXPLORER Water Heater Heat Pump presentation. 6th February 2012

EXPLORER Water Heater Heat Pump presentation. 6th February 2012 EXPLORER Water Heater Heat Pump presentation 6th February 2012 1 1. New Heat-pump Water-heater presentation 1.1 Heat-Pump WH : Different possibilities 1.2 Our solution for each installation choice 1.3

More information

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump

More information

Smardt Water Cooled Chillers

Smardt Water Cooled Chillers Smardt Water Cooled Chillers 60-1140tonR(200-4,000kWr) 1 8 compressors Control cabinet Evaporator Condenser Smardt Air Cooled Chillers 60-430TR (200-1500kWr) 1 4 compressors Condenser with EC-fans Evaporator

More information

AIR CONDITIONING & HEATING SOLUTIONS. AquaFORCE. Fixed-speed screw chiller. 250 kw 1700 kw 30XB & 30XBP

AIR CONDITIONING & HEATING SOLUTIONS. AquaFORCE. Fixed-speed screw chiller. 250 kw 1700 kw 30XB & 30XBP d e s i g n i n g i n n o v a t i v e s o l u t i o n s AIR CONDITIONING & HEATING SOLUTIONS AquaFORCE proven perfomance Fixed-speed screw chiller 250 kw 1700 kw 30XB & 30XBP Carrier committed to environmental

More information

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC. B. Testing, adjustment, and balancing of refrigerating systems.

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC. B. Testing, adjustment, and balancing of refrigerating systems. SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Testing, adjustment, and balancing of air systems. B. Testing, adjustment, and balancing of refrigerating

More information

shedding on any DYNACIAT unit. CMS RS 485 MODBUS/JBUS LONWORKS (option)

shedding on any DYNACIAT unit. CMS RS 485 MODBUS/JBUS LONWORKS (option) NA 04.47 C high-efficiency performance A new technological leap forward with the DYNACIAT chilled water units and heat pumps. The ideal solution for every requirement : compact, efficient, respects the

More information

Absorption Chillers & Heatpumps

Absorption Chillers & Heatpumps AIRCONDITIONING Absorption Chillers & Heatpumps IBK B.V. T +31 (0)30 638 00 00 Duwboot 19 E info@ibknl.com 3991 CD Houten W www.ibknl.com water Waste heat ->> Recycle energy Steam Exhaust gas About World

More information