7.10 ULTRASONIC ANALYZER

Size: px
Start display at page:

Download "7.10 ULTRASONIC ANALYZER"

Transcription

1 ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 1 OF 6 APPLICATIONS OF ULTRASONIC IN-LINE ANALYZERS IN THE PULP AND PAPER INDUSTRY CHEMICAL PULPING (SULFITE PROCESS) The Sulfite Mills produce a pulp that can be used to make toilet tissue, paper towels, food fillers, and find top quality paper. SULFITE PULPING The pulp and paper industry uses two major chemical pulping process: the Kraft (sulfate) process, and the sulfite process. This process (often also referred to as the acid-sulfite process) involves high-acid cooking liquor and a substantial chemical plant and recovery process. The sulfite process may use an ammonia, calcium, sodium, or magnesium base. Many magnesium sulfite pulp mills have installed a chemical recovery process. Upon the combustion of spent magnesium base liquor, magnesium oxide and sulfur dioxide are produced. We have performed several tests with the following starting points: The red liquor must be analyzed in a 2 inch line or 3 inch line. The temperature during normal operation is between 100 C and 120 C (212 F to 248 F). The pressure is more than 2 bars, with a maximum of 10 bars. The proposed in-line analyzer should read near zero during washing with water. The temperature during washing is 100 C (212 F). SOUND SPEED MEASUREMENTS Sound speeds were measured with our standard MP42 cell attached to a closed chamber of approximately 65 ml. The Model 8100, connected to the sensor, measures twice per second (both temperature and sound speed), as well as the attenuation of the ultrasound. These measurements were logged during the entire test. The cell with sample was heated to 120 C (212 F), and while gradual cooling took place, all measurements were recorded under gentle stirring of the sample inside. The several thousands of measurements that were logged during a 2 hour cool down period served as the basis for establishing the calibration curves. This procedure was repeated with several diluted samples in order to determine the correct relationship between the sound speed and concentration.

2 ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 2 OF 6 TEST RESULTS The graph below shows the relation between sound speed, temperature, and the concentration of red liquor. The graph above shows the relationship between sound speed and the concentration of three different temperatures. The polynomial algorithm that is built in the Model 8100 controller accurately determines the concentration out of any combination of speed and temperature data set. During all tests the sound speed was a steady signal, while the measured sound speed absorption, due to suspended solids, was constant for a specific concentration over the entire temperature range. The absorption is linear with the concentration of the diluted samples, thus making it possible to measure the amount of suspended solids separately, and direct this concentration available through the second analog output. ACCURACY The graph show an average sound speed slope of 3.6 m/s per WT% red liquor increase. This slope is considered good, making a reliable concentration measurement possible. The temperature slope is 2.7 m/s per C increase. This slope is considered good, and in fact it is better than is found with many other successful applications. The algorithm of the Model 8100 takes care of the temperature effect. The best accuracy of the Model 8100 under laboratory conditions is m/s and C. With these numbers, the calculated accuracy is WT%. However, it is assumed that the rough process conditions do not allow such a high accuracy. With an estimated average accuracy of m/s and C, the accuracy of the in-line analysis is 0.08 WT%.

3 ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 3 OF 6 MAINTENANCE The Rhosonics analyzer does not require any maintenance, since the reading is marginally affected by scaling. With the normal rinsing procedure, where hot water with some detergent is used, it is expected that the probe will be cleaned as well, therefore, fit for its purpose. The analyzer is equipped with the polynomial calibration for red liquor, as found in the factory. Should a small difference in reading between the instrument and the laboratory of the customer occur, an easy procedure is sufficient to correct the polynomial calibration. This procedure is only required after the initial installation and first test results. Once calibrated, there is no need to repeat the field calibration, as there are no components that can wear or drift with time. SUSPENDED SOLIDS MEASUREMENT The discussed analysis is primarily measuring the amount of dissolved solids. Eventual suspended solids have a negligible effect on the sound velocity. During the testing, it was noted that some amounts of suspended solids are present in the liquid. These solids do not have an affect on the absorption or attenuation of the ultrasonic signal. The attenuation is measured by the Model 8100 as well. Some additional testing is required to isolate the solids from the liquid in order to make various concentrations of suspended solids. Therefore, a second polynomial calibration can be programmed into the Model 8100 for the period of time that testing will occur in the customer s plant. For the trial period, the attenuation signal will be made available at the second output. This will enable the customer to evaluate the possibility of measuring suspended solids as well. In this way, there will be the ability to measure the real-time concentration of red liquor in the form of dissolved solids, at the same time as the concentration of the suspended solids. RED LIQUOR MONITOR Technical Features include: Measuring range: 40% to 60% Accuracy: % Product temperature: 120 C max. Product pressure: 10 bar max. On-line pipe: 2 inches lbs. Measuring cell type: PEEK Sensor: MCS-FTS-1-EX-2" 150 lbs (W-T-PEEK) Evaluation unit: Model 8100 or 8200 (1 or 2 channels) INSTALLATION IN PRODUCTION

4 ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 4 OF 6 CONCLUSIONS The Rhosonics Model 8100 is a reliable and accurate system that measures the concentration of the red liquor on-line. Under the least ideal process conditions (ie: strongly varying temperatures and varying composition of the red liquor), the accuracy of the sound speed is estimated at m/s, and the temperature accuracy is estimated at C. The resulting worst-case accuracy of the in-line analysis is then WT%. APPLICATIONS After and before digester (control of the cooking liquor to provide optimal digestion of the pulp - 0% to 15%) After washers - red liquor 12% to 20% solids After the multiple (affect evaporator - 10% to 20% and 50% to 70%) EXAMPLE OF SULFITE DIGESTER SONIC ANALYZER BEFORE AND AFTER THE DIGESTER LIQUOR CONTROL. THE CONCENTRATION OF THE COOKING LIQUOR PROVIDES OPTIMAL DIGESTION OF THE PULP.

5 7.10 ULTRASONIC ANALYZER ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 5 OF 6 MEASURING CELL (2" PIPE LBS) PROCON JANUARY 2004

6 7.10 ULTRASONIC ANALYZER ON-LINE CONCENTRATION (RED LIQUOR MEASUREMENT) PAGE 6 OF 6 SULFITE EVAPORATOR SYSTEM RHOSONICS MEASUREMENT OF THE RED LIQUOR DURING THE EVAPORATION PROCESS. THE CONCENTRATION IS MEASURED DIRECTLY ON-LINE WITHOUT CONTACT. RHOSONICS ANALYZER (MODEL 8100), MCS SENSOR PROBE (2") 150 LB CELL. MEASURING CELL WITH SENSOR PROCON JANUARY 2004

PULLUTICS elf STREAM MCA MP AND PAPER MILLS

PULLUTICS elf STREAM MCA MP AND PAPER MILLS Amu. / Io7 PULLUTICS elf STREAM MCA MP AND PAPER MILLS No. 1207 Revised December 1956 (1yR A "-^ 0 APR 26 1957 IseS STATS 1 4 111111 000 00111111111111111 1111 1111111111 11111 1 i liwilihndir FOREST PRODUCTS

More information

SEMINAR OPTIMUM DEGREE OF COOKING FOR BLEACLHABLE SULPHATE PULP FROM SWEETGUM. By James M. Snyder. February 14, Introduction

SEMINAR OPTIMUM DEGREE OF COOKING FOR BLEACLHABLE SULPHATE PULP FROM SWEETGUM. By James M. Snyder. February 14, Introduction SEMINAR OPTIMUM DEGREE OF COOKING FOR BLEACLHABLE SULPHATE PULP FROM SWEETGUM By James M. Snyder February 14, 1973 Introduction Many of the studies of pulping and bleaching optima have concerned themselves

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 Significance of paper Paper is one of the essential commodities in daily life all over the world. It is considered as an index of a country s growth. Several grades of paper

More information

Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification. Low Temperature Gasification

Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification. Low Temperature Gasification Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification Adriaan van Heiningen University of Maine Colloquium on Black Liquor Combustion and Gasification May 13-16, 2003, Park City, Utah Low

More information

Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification

Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification Causticizing Aspects and Sulfur Recovery in Black Liquor Gasification Adriaan van Heiningen University of Maine Colloquium on Black Liquor Combustion and Gasification May 13-16, 2003, Park City, Utah Low

More information

Odyssey Conductivity & Temperature Logger.

Odyssey Conductivity & Temperature Logger. Odyssey Conductivity & Temperature Logger. Contents. Salinity Sensor & Software.... 2 Conductivity Cell Calibration.... 2 Standard Solutions.... 3 Temperature Coefficient... 5 Positioning the Cell....

More information

Integration of a sulfite pulp mill and a viscose plant

Integration of a sulfite pulp mill and a viscose plant Integration of a sulfite pulp mill and a viscose plant Hans Magnusson, Gunnar Henriksson, Ulf Germgård Karlstad University, Karlstad, Sweden COST 1205 Budapest 1 Hypothesis There are several benefits obtained

More information

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Reflection Model AS3/AT3 Ultrasonic- Turbidimeter, Monitek Product Line of Galvanic

More information

Two-Stage O2 Delignification System

Two-Stage O2 Delignification System Two-Stage O2 Delignification System Cuts Mill s Chemical Use, Boosts Pulp Quality Arauco mill in Chile has significantly reduced chlorine, chlorine dioxide, and soda consumption in standard and ECF pulps,

More information

Module 2, Add on Lesson Conductivity Sensor. Student. 90 minutes

Module 2, Add on Lesson Conductivity Sensor. Student. 90 minutes Module 2, Add on Lesson Conductivity Sensor 90 minutes Student Purpose of this lesson Investigate the variation of resistance with conductivity Construct a sensor to measure the conductivity of water Graph

More information

Module 2, Add on Lesson Conductivity Sensor. Teacher. 90 minutes

Module 2, Add on Lesson Conductivity Sensor. Teacher. 90 minutes Module 2, Add on Lesson Conductivity Sensor 90 minutes Teacher Purpose of this lesson Investigate the variation of resistance with conductivity Construct a sensor to measure the conductivity of water Graph

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring Model AT3 Principle of measurement: Ultrasonic reflection Intuitive

More information

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C IRONX.01-1 IRON (Colorimetric) PRINCIPLE SCOPE Organic matter in the sample is destroyed by ignition in the presence of a small amount of sulfuric acid. Iron in the residue is reduced to iron (II) and

More information

Total Dissolved Solids

Total Dissolved Solids Total Dissolved Solids LabQuest 12 INTRODUCTION Solids are found in streams in two forms, suspended and dissolved. Suspended solids include silt, stirred-up bottom sediment, decaying plant matter, or sewage-treatment

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

Combustion Processes in the Forest Products Industry

Combustion Processes in the Forest Products Industry Combustion Processes in the Forest Products Industry An informal presentation by Kenneth M. Nichols, Weyerhaeuser Company Presented to Students and Faculty of the University of Washington at the ME 523

More information

Carbon. Carbon. Carbon parameters: Carbon

Carbon. Carbon. Carbon parameters: Carbon Carbon Carbon Carbon The main task of a wastewater treatment plant is to reduce the total organic load of wastewater in addition to all the progress made in nitrogen and phosphate elimination. Organic

More information

Control of sulfidity in a modern kraft pulp mill

Control of sulfidity in a modern kraft pulp mill Control of sulfidity in a modern kraft pulp mill Executive Summary Many years ago, the kraft pulping liquor circuit used sodium sulfate salt as the main make-up source of cooking chemicals. The make-up

More information

OBS-TRPM On Board System Transient PM Mass Measurement

OBS-TRPM On Board System Transient PM Mass Measurement OBS-TRPM On Board System Transient PM Mass Measurement PEMS-PM Evaluation Program Meeting 13-3-08 PM is a complex, variable mixture of several components Tail Pipe Formation continues in ambient upon dilution

More information

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION Total Dissolved Solids Computer 12 INTRODUCTION Solids are found in streams in two forms, suspended and dissolved. Suspended solids include silt, stirred-up bottom sediment, decaying plant matter, or sewage-treatment

More information

F-2200 Series Steam Meter

F-2200 Series Steam Meter F-2200 Series Steam Meter Vortex Mass Flow Meter for Saturated Steam Accurate cost effective mass flow measurement for saturated steam in a single instrument DESCRIPTION The F-2200 Series Steam Meter is

More information

THE INSTITUTE OF PAPER CHEMISTRY. Appleton, Wisconsin CORROSION PROBLEMS IN THE PULP AND PAPER INDUSTRY. Project 1310.

THE INSTITUTE OF PAPER CHEMISTRY. Appleton, Wisconsin CORROSION PROBLEMS IN THE PULP AND PAPER INDUSTRY. Project 1310. THE INSTITUTE OF PAPER CHEMISTRY Appleton, Wisconsin CORROSION PROBLEMS IN THE PULP AND PAPER INDUSTRY Project 1310 April 1, 1949 THE INSTITUTE OF PAPER CHEMISTRY Appleton, Wisconsin INTRODUCTION Some

More information

Dry matter content and fibre content

Dry matter content and fibre content Revised 1996 Black liquor Dry matter content and fibre content 0 Introduction This SCAN-test Standard replaces SCAN-N 22:77 from which it differs in that it also provides a procedure for the determination

More information

EQUILIBRIUM OF LIGNIN PRECIPITATION

EQUILIBRIUM OF LIGNIN PRECIPITATION EQUILIBRIUM OF LIGNIN PRECIPITATION Weizhen Zhu 1 and Hans Theliander 1* 1. Forest Products and Chemical Engineering, Department of Chemical and Biological Engineering, Chalmers University of Technology,

More information

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution

More information

Waterside Cleaning of Recovery Boilers.. Pay Now or Pay Later

Waterside Cleaning of Recovery Boilers.. Pay Now or Pay Later Waterside Cleaning of Recovery Boilers.. Pay Now or Pay Later Norris N. Johnston Application Team Manager Water Management Technology Lacey s Spring, Alabama USA Quebec City_06202006-1 Waterside Cleaning

More information

Institute of Paper Science and Technology Atlanta, Georgia IPST TECHNICAL PAPER SERIES

Institute of Paper Science and Technology Atlanta, Georgia IPST TECHNICAL PAPER SERIES Institute of Paper Science and Technology Atlanta, Georgia IPST TECHNICAL PAPER SERIES NUMBER 481 EFFECTS OF REDUCED FRESH WATER USAGE ON ION BUILDUP IN A TYPICAL PAPER MACHINE WATER SYSTEM G.L. JONES

More information

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter. TM FPI Mag TM SPI Mag Insertion Flow Meters The only hot tap Full Profile Insertion Flow Meter. Easy to install, rivals performance Economical for medium and large line sizes The total installed cost of

More information

Millennium Plastics. Implementing Energy Efficiency

Millennium Plastics. Implementing Energy Efficiency 04 Millennium Plastics Implementing Energy Efficiency Since having an energy audit in 2009, Hamilton injection moulding company Millennium Plastics, have shaved 15% off their annual electricity costs by

More information

With Discovery Incubator.

With Discovery Incubator. TEST KIT POTABLE WATER With Discovery Incubator. FEATURES & BENEFITS 8 dip slide capacity Compact and convenient design Weighs only 1.2 kg Temperature range: ambient +5 to 45 C Accurate temperature control

More information

WHITE PAPER NO. 12 COMPARISON OF KRAFT, SULFITE, AND BCTMP MANUFACTURING TECHNOLOGIES FOR PAPER DECEMBER

WHITE PAPER NO. 12 COMPARISON OF KRAFT, SULFITE, AND BCTMP MANUFACTURING TECHNOLOGIES FOR PAPER DECEMBER PAPER TASK FORCE Duke University ** Environmental Defense Fund Johnson & Johnson ** McDonald's The Prudential Insurance Company of America ** Time Inc. WHITE PAPER NO. 12 COMPARISON OF KRAFT, SULFITE,

More information

T 619 cm-84 TENTATIVE STANDARD 1933 OFFICIAL STANDARD 1935 CORRECTED 1944 CORRECTED 1953 CLASSICAL METHOD TAPPI. Analysis of salt cake

T 619 cm-84 TENTATIVE STANDARD 1933 OFFICIAL STANDARD 1935 CORRECTED 1944 CORRECTED 1953 CLASSICAL METHOD TAPPI. Analysis of salt cake T 619 cm-8 TENTATIVE STANDARD 19 OFFICIAL STANDARD 195 CORRECTED 19 CORRECTED 195 CLASSICAL METHOD 198 198 TAPPI The information and data contained in this document were prepared by a technical committee

More information

PRODUCTION EFFICIENCY/ POLLUTION PREVENTION FACTORY ASSESSMENTS FOR FABRIC MILLS AND DYE HOUSES IN BANGLADESH

PRODUCTION EFFICIENCY/ POLLUTION PREVENTION FACTORY ASSESSMENTS FOR FABRIC MILLS AND DYE HOUSES IN BANGLADESH গ ণ প রজ ত ন ত র ব ল দ শ PEOPLE S REPUBLIC OF BANGLADESH PRODUCTION EFFICIENCY/ POLLUTION PREVENTION FACTORY ASSESSMENTS FOR FABRIC MILLS AND DYE HOUSES IN BANGLADESH Dhaka, 8 May 2011 Summary 1. The approach

More information

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring. High /H comp NO NOx 2 LANM 4 www.lancom4.com NO2 2 H2S SO2 CXHY Portable Flue Gas Monitoring LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available.

More information

EXPERIMENT 15 FREEZING POINT: A COLLIGATIVE PROPERTY OF SOLUTIONS

EXPERIMENT 15 FREEZING POINT: A COLLIGATIVE PROPERTY OF SOLUTIONS EXPERIMENT 15 FREEZING POINT: A COLLIGATIVE PROPERTY OF SOLUTIONS INTRODUCTION Scientists seldom work alone today. Instead they work in teams on projects, sharing the labor of carrying out the experiments

More information

ENERGY MODEL FOR AN INDUSTRIAL PLANT USING GEOTHERMAL STEAM IN NEW ZEALAND

ENERGY MODEL FOR AN INDUSTRIAL PLANT USING GEOTHERMAL STEAM IN NEW ZEALAND ENERGY MODEL FOR AN INDUSTRIAL PLANT USING GEOTHERMAL STEAM IN NEW ZEALAND G.W. Hotson 1 and G. Everett 2 1 Project Engineer, Fletcher Challenge Paper Australasia Ltd, Private Bag, Kawerau, New Zealand

More information

COLow COHigh COLow/H 2

COLow COHigh COLow/H 2 High / comp NO NOx NO2 2 H2S Portable Flue Gas Monitoring SO2 LANM 4 CXHY www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In

More information

Experiment 8. Determination of Iron in an Ore by Potentiometric Titration. Iron ores are often completely decomposed in hot concentrated HCl.

Experiment 8. Determination of Iron in an Ore by Potentiometric Titration. Iron ores are often completely decomposed in hot concentrated HCl. Experiment 8 Determination of Iron in an Ore by Potentiometric Titration Introduction The common iron ores are hematite (Fe 2 O 3 ), magnetite (Fe 3 O 4 ), and limonite (3Fe 2 O 3 3H 2 O). Volumetric methods

More information

The determination of copper in brass

The determination of copper in brass The determination of copper in brass Objective - To determine the amount of copper in a brass sample Background Brass is an alloy made of copper and zinc. Most brass contains about 60% copper. The proportions

More information

Results of the PhD Thesis on real time refractive index measurement in washing process optimization and control

Results of the PhD Thesis on real time refractive index measurement in washing process optimization and control Results of the PhD Thesis on real time refractive index measurement in washing process optimization and control Riku Kopra, FiberLaboratory Mikkeli University of Applied Sciences Riku.kopra@mamk.fi Content

More information

AlfaNova 14. Fusion plate heat exchanger

AlfaNova 14. Fusion plate heat exchanger AlfaNova 14 Fusion plate heat exchanger General information AlfaNova is a plate heat exchanger made of 100% stainless steel. It is based on Alfa Laval s new revolutionary technology, AlfaFusion, the art

More information

Pulp mill optimization no longer pulp fiction

Pulp mill optimization no longer pulp fiction Pulp mill optimization no longer pulp fiction Producing high-quality pulp consistently with advanced process control ABHIJIT BADWE, RAMESH SATINI When Mondi the global paper and cardboard producer decided

More information

Lecture 26: Preparation of wood pulp by sulfate (kraft) process

Lecture 26: Preparation of wood pulp by sulfate (kraft) process Lecture 26: Preparation of wood pulp by sulfate (kraft) process 26.1 What is pulp? Pulp is a commercial fibrous material obtained from bamboo, wood, bagasse (waste material) etc. by mechanical and chemical

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200

More information

Energy and water in the pulp and paper industry: the two solitudes

Energy and water in the pulp and paper industry: the two solitudes Energy and water in the pulp and paper industry: the two solitudes Enrique Mateos Espejel, Lovina Madtha, Mariya Marinova, Jean Paris Department of Chemical Engineering, Ecole Polytechnique de Montreal

More information

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR Flow Pressure Level Temperature measurement monitoring control Revolutionary Microprocessor-Based Drift Stabilization NPT and 3-A Compliant Sanitary Fittings Non-Corrosive

More information

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows Manganese DOC316.53.01058 USEPA 1 Periodate Oxidation Method 2 Method 8034 0.1 to 20.0 mg/l Mn (HR) Powder Pillows Scope and application: For soluble manganese in water and wastewater. 1 USEPA Approved

More information

Odorless pulp mill in successful operation

Odorless pulp mill in successful operation Odorless pulp mill in successful operation Executive Summary The sulphur in the cooking process can result in bad odor in the surroundings of a Kraft pulp mill. Together with the odor, sulphur compounds

More information

When this process occurs in water, the oxygen consumed is dissolved oxygen.

When this process occurs in water, the oxygen consumed is dissolved oxygen. Theory: BOD is Biochemical Oxygen Demand Referred to as a standardized laboratory procedure used to determine the relative oxygen requirements of wastewaters, effluents and polluted water. It is a measures

More information

DIRECT STEAM INJECTION HEATER SERIES

DIRECT STEAM INJECTION HEATER SERIES Several processes require precision control of liquid temperature to achieve the right product without degradation or denaturing. In such applications where dilution of the liquids by water is not a concern,

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10173 ORGANIC CARBON, TOTAL, Mid Range (15 150 mg/l C) Direct Method * For wastewater and industrial waters HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103 105 C. Note: See DRB 200 user

More information

Soda Ash ( Sodium carbonate) Manufacture

Soda Ash ( Sodium carbonate) Manufacture Soda Ash ( Sodium carbonate) Manufacture Pertinent properties Mol. Wt. 106 M.P. 851deg.C. B.P. Decomposes Soluble in water 8.9 gm/100gm at 20 deg.cel. Grade s: 99% sodium carbonate washing soda ( Na 2

More information

Copper Odyssey. Chemical Reactions of Copper

Copper Odyssey. Chemical Reactions of Copper Name Lab Partner(s) Copper Odyssey Chemical Reactions of Copper Date Period Elemental copper metal will be converted into copper (II) ion and then brought through a series of compound conversions until

More information

Final Report for COMPOTOOL LTD

Final Report for COMPOTOOL LTD Final Report for COMPOTOOL LTD MOISTURE EXPANSION MEASUREMENTS OF CT850 TOOLING BOARD SPECIMENS September 5, 2014 Paul Hackett TEL: +64 (9) 573-1970 FAX: +64 (9) 573-1973 COMPOTOOL LTD 39 Vestey Drive

More information

Mass flow measurement without media contact

Mass flow measurement without media contact mass flow, density and concentration measurement without media contact FLEXIM includes an extensive and continuously growing database for the non-invasive determination of mass flow and concentration of

More information

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate. Change to read: Talc» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate. Packaging and storage Preserve in well closed containers. Identification

More information

The Haberdashers' Aske's Boys School Elstree, Herts. 13+ Entrance Examination 2015

The Haberdashers' Aske's Boys School Elstree, Herts. 13+ Entrance Examination 2015 The Haberdashers' Aske's Boys School Elstree, Herts 13+ Entrance Examination 2015 CHEMISTRY Please follow these instructions The Science paper is divided into three sections (Biology, Chemistry and Physics).

More information

Valmet Online Learning

Valmet Online Learning Course English Chinese Russian Swedish Portuguese Spanish Finnish Hungarian Upcoming languages Learning Continuous cooking x x x x x 17 3-4 Superbatch cooking x x 3 About 2 White liquor plant x x x 26

More information

CHLOR-ALKALI INDUSTRY

CHLOR-ALKALI INDUSTRY CHLOR-ALKALI INDUSTRY The chlor-alkali industry represents of three major industrial chemicals: Soda ash (sodium carbonate-na 2 CO 3 ) Caustic soda (sodium hydroxide-naoh) Chlorine (Cl 2 ) These chemicals

More information

COLow COHigh COLow/H 2

COLow COHigh COLow/H 2 High /H comp NO NOx NO HS Portable Flue Gas Monitoring SO LANM 4 CXHY www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In excess

More information

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure) While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the

More information

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium. , 8017 Dithizone Method 1 DOC316.53.01012 Method 8017 (0.7 to 80.0 µg/l) Powder Pillows Scope and Application: For water and wastewater; digestion is required to determine total cadmium. 1 Adapted from

More information

Uranium Testing and On Site Calibration for Water Testing Detection Range: 2 60ppb

Uranium Testing and On Site Calibration for Water Testing Detection Range: 2 60ppb Document: AND010 08 2017 Uranium Testing and On Site Calibration for Water Testing Detection Range: 2 60ppb August 2017 Edition 2 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Uranium Testing

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Bromine T 0.05-13 mg/l Br 2 DPD 80 Br Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine T a) 0.01-6.0 mg/l Cl 2 DPD 100 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Amperometric Titrator assembly. Digital Titrator. Beaker, low-form, 250-mL. Stir bar, octagonal, Teflon-coated, 50.8 x 7.9 mm

Amperometric Titrator assembly. Digital Titrator. Beaker, low-form, 250-mL. Stir bar, octagonal, Teflon-coated, 50.8 x 7.9 mm , AFT, DT, 10024 P DOC316.53.01220 Amperometric Forward Titration using 0.00564 N PAO 1 Method 10024 (0 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator Scope and Application: For drinking water; USEPA

More information

Mixed Salt Recovery for High Quality Pulp (MSRP)

Mixed Salt Recovery for High Quality Pulp (MSRP) Mixed Salt Recovery for High Quality Pulp (MSRP) Green Manufacturing for Sustainable Business Waste to Value Cost saving & Environment Dr. Jirachote Phattaranawik and Team Central R&D, SCG Chemicals Topics

More information

Chemistry. Freezing and Melting of Water ID: By Texas Instruments TEACHER GUIDE

Chemistry. Freezing and Melting of Water ID: By Texas Instruments TEACHER GUIDE Freezing and Melting of Water ID: 16150 By Texas Instruments TEACHER GUIDE Time required 90 minutes Topic: Phase Changes Relate freezing point and melting point. Interpret a heating or cooling curve. Describe

More information

8.3 Preparation of Salts

8.3 Preparation of Salts For more awesome GSE and level resources, visit us at www.savemyexams.co.uk/ 8. Preparation of Salts Question Paper Level IGSE Subject hemistry (060) Exam oard ambridge International Examinations (IE)

More information

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring.  comp NO NOx High /H comp NO NOx Portable Flue Gas Monitoring LANM 4 NO H S SO C X H Y www.lancom4.com LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In

More information

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. // XPLORER-NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the Xplorer-NS, a Total Nitrogen and Total Sulfur combustion analyzer, offering

More information

VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL

VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL GENERAL INFORMATION Van London combination electrodes offer the convenience of having the reference and measuring electrodes combined in a

More information

Iron 10 T mg/l Fe Ferrozine / Thioglycolate

Iron 10 T mg/l Fe Ferrozine / Thioglycolate Iron 10 T 0.05-1 mg/l Fe Ferrozine / Thioglycolate 218 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of

More information

Chemical Pulp Mills. Kraft (Sulfate) Pulping. Chemical Pulp Mills

Chemical Pulp Mills. Kraft (Sulfate) Pulping. Chemical Pulp Mills Chemical Pulp Mills Pulping is the term used for the process which separates wood fibers. Chemical pulping, dissolving the lignin in the wood to create a pulp, is the most commonly used pulping process.

More information

Verso Quinnesec LLC & Specialty Minerals (Michigan) Inc. SRN: B7192. Located at. Staff Report Date: May 6, 2013

Verso Quinnesec LLC & Specialty Minerals (Michigan) Inc. SRN: B7192. Located at. Staff Report Date: May 6, 2013 State Registration Number Michigan Department of Environmental Quality Air Quality Division RENEWABLE OPERATING PERMIT ROP Number B7192 STAFF REPORT MI-ROP-B7192-2013 Verso Quinnesec LLC & Specialty Minerals

More information

Portable Ultrasonic Flowmeter

Portable Ultrasonic Flowmeter DUS-TT-V Heat meter option The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses

More information

F U C H S L U B R I C A N T S C O.

F U C H S L U B R I C A N T S C O. F U C H S L U B R I C A N T S C O. SENSOR INFORMATION, CARE AND WARRANTY RM CONCENTRATION / BRIX SENSOR RANGE: 0-35 BRIX GENERAL RM CONCENTRATION SENSOR CARE AND MAINTENANCE RECOMMENDATIONS BY MANUFACTURER

More information

Our mission is to provide cost effective, safe, environmentally responsible solutions to bacterial control in the food and water industries

Our mission is to provide cost effective, safe, environmentally responsible solutions to bacterial control in the food and water industries Our mission is to provide cost effective, safe, environmentally responsible solutions to bacterial control in the food and water industries The T25 series of Disinfectant Generators The T25 is available

More information

WALL THICKNESS MEASUREMENT OF LARGE TUBE DIAMETERS USING PHASED ARRAY TECHNOLOGY

WALL THICKNESS MEASUREMENT OF LARGE TUBE DIAMETERS USING PHASED ARRAY TECHNOLOGY WALL THICKNESS MEASUREMENT OF LARGE TUBE DIAMETERS USING PHASED ARRAY TECHNOLOGY H. Lompe 1, O.Dillies 2, S. Nitsche 3, Ch. Delhaes 3 and G. Kauth 1 1 GE Inspection Technologies, Huerth, Germany 2 Vallourec

More information

PIOX S FLEXIM. No more corrosion and mechanical failures. Non-intrusive concentration, density and flow measurement of aggressive media

PIOX S FLEXIM. No more corrosion and mechanical failures. Non-intrusive concentration, density and flow measurement of aggressive media No more corrosion and mechanical failures PIOX S Non-intrusive concentration, density and flow measurement of aggressive media Concentration & Volume Flow Density & Mass Flow Phase Detection Product Recognition

More information

Recovery & Utility Management

Recovery & Utility Management Recovery & Utility Management Jim Brewster Mill Manager Irving Pulp & Paper, Limited Saint John, New Brunswick, Canada Tappi Kraft Recovery Short Course St. Petersburg, FL, January 7-10, 2008 Recovery

More information

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right , 8374 Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method ULR (4 to 1000 µg/l Ca and Mg as CaCO 3 ) Scope and Application: For boiler and ultra pure water. DOC316.53.01045 Method 8374 Pour-Thru

More information

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc. Evaporative Condenser Passivation Cameron Klein Strand Associates, Inc. Evaporative Condenser Wetted Surface Materials of Construction Galvanized Steel Protective zinc coating fused to a steel substrate

More information

A Cycle of Copper Reactions

A Cycle of Copper Reactions EXPERIMENT A Cycle of Copper Reactions PURPOSE To demonstrate a series of copper reactions: starting with copper metal, oxidizing the metal to put it into solution and then, form a copper hydroxide, an

More information

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows Manganese, LR DOC316.53.01057 1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method 8149 0.006 to 0.700 mg/l Mn (LR) Powder Pillows Scope and application: For water and wastewater; digestion is necessary for

More information

) > Lead > Nickel > Zinc > Cadmium > Iron(II) > Beryllium > Manganese > Calcium > Magnesium > Strontium > Barium >>> Sodium.

) > Lead > Nickel > Zinc > Cadmium > Iron(II) > Beryllium > Manganese > Calcium > Magnesium > Strontium > Barium >>> Sodium. Lewatit MonoPlus TP 207 XL is a weakly acidic, macroporous cation exchange resin with chelating iminodiacetate groups for the selective extraction of heavy metal cations from weakly acidic to weakly basic

More information

SmartScanTM. SolidScan You Can Measure the Solid Benefits. Ultrasonic Continuous Level Measurement of Liquids and Solids

SmartScanTM. SolidScan You Can Measure the Solid Benefits. Ultrasonic Continuous Level Measurement of Liquids and Solids SmartScanTM Ultrasonic Continuous Level Measurement of Liquids and Solids Automatic adaptation to virtually all environments Radar-like performance at an affordable price Superior reliability and accuracy

More information

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s) Cycle of Copper Reactions Lab Exercise The following is a protocol for the multi-step transformation of copper metal based upon the following chemical transformations: Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO

More information

Rev Experiment 10

Rev Experiment 10 Experiment 10 SPECTROPHOTOMETRIC DETERMINATION OF IRON IN DRINKING WATER 2 lab periods Reading: 1) Chapter 17, pg 393-403, Quantitative Chemical Analysis, 8 h Edition, Daniel C. Harris (7 th Edition: Chapter

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical Oxygen Demand, Chemical DOC316.53.01101 Manganese III Reactor Digestion Method (with chloride removal) Method 10067 30 to 1000 mg/l COD Mn Test N Tube Vials Scope and application: For water and wastewater

More information

Pulp and paper industry. Arun S

Pulp and paper industry. Arun S Pulp and paper industry Arun S 1 Introduction The pulp and paper industry converts wood or recycled fibre into pulp and primary forms of paper. In the 1800s, there was a shift away from using cotton rags

More information

Scandinavian Hardwood Biorefinery Using Near-Neutral Hemicelluloses Pre-extraction Energy Efficiency Measures

Scandinavian Hardwood Biorefinery Using Near-Neutral Hemicelluloses Pre-extraction Energy Efficiency Measures Scandinavian Hardwood Biorefinery Using Near-Neutral Hemicelluloses Pre-extraction Energy Efficiency Measures Valeria Mora (Lundberg)*, Maryam Mahmoudkhani, Thore Berntsson Division of Heat and Power Technology,

More information

Pipe Flow Hydraulics

Pipe Flow Hydraulics CHE- 3115 Chemical Engineering Processes I - Laboratory Experiment 1 Pipe Flow Hydraulics BACKGROUND The conveyance of fluids through fixed conduits is the most common unit operation in engineering practice.

More information

Evaluation of Copper Stave Remnant Thickness in Blast Furnace Using Ultrasonic Method

Evaluation of Copper Stave Remnant Thickness in Blast Furnace Using Ultrasonic Method , pp. 605 610 Evaluation of Copper Stave Remnant Thickness in Blast Furnace Using Ultrasonic Method Sriniwasagan BALAMURUGAN, 1) * Rajendran SHUNMUGASUNDARAM, 1) Mantu PATRA, 2) Sameeran PANI 2) and Monojit

More information

Chapter 8. Gravimetric Analysis

Chapter 8. Gravimetric Analysis Chapter 8 Gravimetric Analysis Gravimetric analysis is the use of weighing to determine the amount of a component in your sample. Gravimetric analysis, or gravimetry is normally performed either as a :

More information

Other Relevant SNAP Codes for Paper Pulping - Acid Sulphite Process

Other Relevant SNAP Codes for Paper Pulping - Acid Sulphite Process Pr40603 Activity 040603 SNAP CODE: 040603 SOURCE ACTIVITY TITLE: PROCESSES IN WOOD, PAPER PULP, FOOD, DRINK AND OTHER INDUSTRIES Paper Pulp (Acid Sulphite Process) NOSE CODE: 105.07.02 NFR CODE: 2 D 1

More information

AP Chemistry Reaction Set

AP Chemistry Reaction Set Class: Date: AP Chemistry Reaction Set 2009-2010 Other 1. Pure solid phosphorus (white form) is burned in air. (2002) 2. Sulfur dioxide gas is bubbled into distilled water. (2001) 3. A drop of potassium

More information