Next Generation District Heating

Size: px
Start display at page:

Download "Next Generation District Heating"

Transcription

1 Next Generation District Heating FVB: Ulrika Ottosson, Heimo Zinko Lund University: Janusz Wollerstrand, Patrick Lauenburg, Marek Brand (DTU) a project The Swedish District Heating Association s R&D programme

2 Next Generation DH in Sweden Today: Large market penetration, almost 60 % Future: Changed heat load profiles to expect Impact on: Network operation and design Heat and power production Substation/HVAC design Economy and environment

3 Residential Changes Retrofitting Existing Areas Densifying City Center New Developments

4 Increased energy efficiency in area Rud, Karlstad ( million programme building) Improved building envelope Exhaust air recovery Improved control Reduced annual heat load and peak load

5 DH Load (W/m2) How different measures changes the DH load 50 DH load before retrofit (W/m2) DH Load with 20% reduction in space heating load (W/m2) 40 DH Load with 20% reduction in space heating + Heat recovery ventilators (W/m2) DH Load with 20% reduction in space heating + Exhaust air heat pumps for rad (W/m2) DH Load with 20% reduction in space heating load + Exhaust air heat pumps for rad and DHW (W/m2) Duration (h)

6 Yearly consumption various scenarios 160 kwh/m2 140 kwh/m2 District Heating Electricity 120 kwh/m2 100 kwh/m2 80 kwh/m2 60 kwh/m2 40 kwh/m2 20 kwh/m2 0 kwh/m2 Before retrofit 20% Space heating reduction 20% Space Heating Reduction + Heat Recovery Ventilators 20% Space heating reduction + Exhaust Air Heat Pumps for rad 20% Space heating reduction + Exhaust Air Heat Pumps for rad&dhw

7 New Development with Single Detached Houses A low heat density area with 58 dwellings (50 connected to DH) low energy houses and houses with solar collectors Connection to main DH network

8 Energy (MWh) Yearly Load for Area of Single Houses (50 low energy houses, of which half have solar heating) 100 Heating (MWh) Appliances (MWh) Primary Connection Heat Losses (MWh) DHW (MWh) Secondary Connection Heat Losses (MWh) Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

9 Single detached house area primary connection to DH system Pressure either increase pressure in whole system or booster pump Same temperatures as the whole system, i.e. substantial heat losses Pipes, components and substation must be designed for high pressures and temperatures higher installation costs and limited freedom for system layout

10 Single detached house area secondary connection to DH system Pressure 1-1,5 bars at area substation enough For new-built houses supply temperature of C enough Plastic pipes can be used which can reduce installation costs May result in multiple heat exchange

11 Next Generation DH substation Forced air ventilation with heat coil providing low return temperature

12 Next Generation DH substation Forced air ventilation with heat coil providing low return temperature Domestic hot water prioritization with or without directly connection of waterborne heating

13 Next Generation DH substation Forced air ventilation with heat coil providing low return temperature Domestic hot water prioritization with or without directly connection of waterborne heating Flat substations in multiresidential building

14 Next Generation DH substation Forced air ventilation with heat coil providing low return temperature Domestic hot water prioritization with or without directly connection of waterborne heating Flat substations in multiresidential buildings In case of solar heating for domestic use domestic hot water storage

15 Consumer installations Not evident what HVAC system will dominate in the future Radiators, underfloor heating, airborne heating New control systems required Not only outdoor temperature important, but much larger influence from human behaviour Heat supply via air in the first Swedish passive houses, but indications for comeback of waterborne heating

16 Literature review Experiences from e.g. Denmark, flat substations, lowtemperature DH Low energy buildings Evaluation of passive houses In general good, but bathrooms generally in need of heat source Comfort heating often requested by users Heat supply when ventilation is turned off (during vacations etc.) Concerns regarding heat distribution via air

17 Literature review Indoor temperature in low energy buildings mainly affected by variations in internal heat gains not outdoor temperature Fast variations, but long time constants due to good insulation Different opinions regarding use of underfloor heating (and comfort floor heating)

18 Literature review Passiv houses industry has not disqualified waterborne heating, only a matter of economy A positive attitude towards DH as heat source in future low-energy houses (Not an equally positive attitude towards DH industry)

19 Adaptive control of radiator systems - a way to reduce supply temperatures? Continuation of a successful project were a new control algorithm for radiator system control was developed By control of not only radiator supply temperature but also radiator system flow rate, the return temperature could be reduced by approx. 2 dgc in four tested buildnings The algorithm will adapt to external changes, e.g. an improved building envelope or a reduced DH supply temperature. Simulations show that can be a useful tool to handle existing buildings in an area where you want to reduce the network supply temperature

20 Other studies within the project Field study of old secondary network Two equal secondary systems, both with 80 detached house built during 70ies, one of these performs poorly Methods to optimize temperatures and flow rate Comparison of different heating systems radiators, underfloor heating and forced air heating with regards to return temperature, peak load and operating hours

21 Thanks! Ulrika Ottosson, FVB Patrick Lauenburg, Lund University

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale The Future Role of Energy Storage in South Eastern Europe Enlargement and Integration Action Workshop Strategies for energy efficiency improvement in residential and office buildings: their role at building

More information

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016 Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's PDF, also known as Version of record Link to publication

More information

District Heating for Energy Efficient Building Areas

District Heating for Energy Efficient Building Areas IEA DHC/CHP Annex IX District Heating for Energy Efficient Building Areas Kari Sipilä VTT Technical Research Centre of Finland 2 Co-partners: VTT Energy Systems FVB Sverige AB BB Energiteknik Building

More information

Heat Pump Field Trials and Implications for Design

Heat Pump Field Trials and Implications for Design Heat Pump Field Trials and Implications for Design GSHPA 26 th June 2012 Chris Laughton Managing Director The Solar Design Company 1 Contents German Fraunhofer trials 2011 Comparison with UK Heat Pump

More information

Progress of Nordic Built project_nb13339 Low temperature heating and high temperature cooling in refurbishments and new construction of buildings

Progress of Nordic Built project_nb13339 Low temperature heating and high temperature cooling in refurbishments and new construction of buildings Progress of Nordic Built project_nb13339 Low temperature heating and high temperature cooling in refurbishments and new construction of buildings Low temperature heating (LTH) group: Sture Holmberg, Professor,

More information

Solar Thermal Optimization for District Hot Water through Energy Modeling

Solar Thermal Optimization for District Hot Water through Energy Modeling Solar Thermal Optimization for District Hot Water through Energy Modeling Joshua Morejohn, Energy Manager Priscila Castillo Cazares, JEMES CiSu UC Davis is converting their district heating system from

More information

Motivation tariff the key to a low temperature district heating network

Motivation tariff the key to a low temperature district heating network Motivation tariff the key to a low temperature district heating network Initiative A district heating company have a good reason to lower the temperature in the network. It gives a lot of different possibilities

More information

Verified net Zero Energy Building with air source heat pumps for SME

Verified net Zero Energy Building with air source heat pumps for SME Verified net Zero Energy Building with air source heat pumps for SME Field measurements were conducted on a net zero energy building designed for small to medium enterprises (SMEs). Energy flow and comfort

More information

New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable

New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable Energy Sources Solar Thermal Dept. Overview Solar Thermal

More information

RAMBOLL THERMAL TECHNOLOGY WITH DISTRICT ENERGY SYSTEMS

RAMBOLL THERMAL TECHNOLOGY WITH DISTRICT ENERGY SYSTEMS RAMBOLL THERMAL TECHNOLOGY WITH DISTRICT ENERGY SYSTEMS RAMBOLL ENERGY REFERENCES 800 ENERGY SPECIALISTS EVOLUTION OF DISTRICT HEATING HOEJE TAASTRUP DISTRICT HEATING COMPANY DISTRICT ENERGY NETWORKS (PLANNED

More information

Solar Energy Technologies

Solar Energy Technologies 1 Solar Energy Technologies ME 430 Queen s University The Solar Energy Resource Varies over day and year, (i.e., intermittent) Generally non-dispatchable Ottawa average for year ~4 kwh/m 2 per day e.g.,

More information

Project PolarSol koti 41\193\- Map section

Project PolarSol koti 41\193\- Map section Project PolarSol koti 41\193\- Location of the system Map section Profil Longitude: 24.109 Latitude: 65.841 Elevation: 11 m This report has been created by: Anton Serbin +358447887888 Dealer: www.profil.fi

More information

Innovative Solar thermal systems for heating and cooling

Innovative Solar thermal systems for heating and cooling Innovative Solar thermal systems for heating and cooling Warsaw 18 th June 2009 Panagiotis Tsekouras PhD Candidate Mechanical Engineer CRES - Solar Thermal Dept. Overview The HIGH COMBI project SC+ Symbolism

More information

SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST

SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST BACKGROUND The Welsh School of Architecture has designed and built Wales first low cost energy positive house. The Solcer House is capable of exporting

More information

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort Energy-Efficient Passive House using thermal mass to achieve high thermal comfort Loa Andersson Managing Director RLI Byggdata AB rli@termodeck.com Alexander Engström Technical Director RLI Byggdata AB

More information

Project Report: SunMaxx Commercial Case Studies

Project Report: SunMaxx Commercial Case Studies Project Report: 14 x ThermoPower-VHP30 Total Gross Surface Area: 738.50 sq.ft Azimuth: 10 Incl.: 37 2100 gal/day 130 F Gas Boiler - 9 150 kbtu/hr StorMaxx NP Vol:2500 gal Existing Hot Water Heater Vol:1000

More information

Low energy buildings

Low energy buildings Low energy buildings the basis for realizing the strategy for independency of fossil fuels in 2050 NSB 2011 Tampere 2011-05-31 Professor Svend Svendsen Department of Civil Engineering Technical University

More information

Simulation based façade control implemented as a responsive building element

Simulation based façade control implemented as a responsive building element Simulation based façade control implemented as a responsive building element Axel Seerig, Carina Sagerschnig Gruner AG, Basel, Switzerland Smart and Efficient Energy Council (SEEC 2009) 1 Trento / Italy,

More information

SolarCity Partnership. Toronto Fire Station # kwt Solar Water Heating Installation. Technology. Monitoring. Best Practices

SolarCity Partnership. Toronto Fire Station # kwt Solar Water Heating Installation. Technology. Monitoring. Best Practices Toronto Fire Station #212 12.5 kwt Solar Water Heating Installation Final Report January 2012 Technology Monitoring Best Practices SolarCity Partnership PROJECT SNAPSHOT Address: 8500 Sheppard Avenue East,

More information

Swedish development of Energy-efficient buildings

Swedish development of Energy-efficient buildings Melbourne Forum September 2011 Swedish development of Energy-efficient buildings From reduction of energy use to increased use of renewable energy Maria Wall Energy and Building Design Lund University,

More information

California Independent System Operator Corporation. California ISO. Import resource adequacy. Department of Market Monitoring

California Independent System Operator Corporation. California ISO. Import resource adequacy. Department of Market Monitoring k California Independent System Operator Corporation California ISO Import resource adequacy September 10, 2018 Department of Market Monitoring Summary This report provides an update of analysis and trends

More information

Assignment 3 Integrated Energy Design

Assignment 3 Integrated Energy Design Assignment 3 Integrated Energy Design AAR4926 Marco Rimensberger Shabnam Arbab Shangyi Sun May 2012 Page 0 Contents 1 Introduction... 2 2 Background... 2 3 Design Progress... 2 3.1 Available Energy Sources...

More information

Hot water persons. Map section

Hot water persons. Map section Project Hot water 4-160 persons Location of the system Rapperswil SG Longitude: 8.82 Latitude: 47.23 Elevation: 417 m Map section "Current report item is not supported in this report format." This report

More information

IEA s Energy Conservation for Buildings and Community Systems: Overview

IEA s Energy Conservation for Buildings and Community Systems: Overview IEA s Energy Conservation for Buildings and Community Systems: Overview Morad R. Atif, Ph.D. Chairman, Executive Committee Energy Conservation for Buildings and Community Systems s Energy Conservation

More information

Efficient utilization of energy sources

Efficient utilization of energy sources Efficient utilization of energy sources Perspectives for the reduction of fossil primary energy utilization in urban areas March 28 Using the energy content the most efficient way is using COMBINED HEAT

More information

Hotels: Water and Energy

Hotels: Water and Energy Hotels: Water and Energy Agenda 01 Introduction 05 Hotel System Options 02 Company Overview 06 Hotel Energy Conservation 03 Hotel Energy & Water Use 07 Hotel Project Examples 04 Design Philosophy Introduction

More information

Energy Saving Public Swimming Complex In Finland

Energy Saving Public Swimming Complex In Finland Energy Saving Public Swimming Complex In Finland Suvi Karirinne 1,a, Petri Konttinen 2,b, and Jukka Kotiniemi 3 1 Faculty of Energy and Construction, Satakunta University of Applied Science, Tiedepuisto

More information

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA Bulletin of the Transilvania University of Braşov Series I: Engineering Sciences Vol. 5 (54) No. 2-212 ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA C. ŞERBAN 1 E. EFTIMIE 1 Abstract:

More information

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions.

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions. Luxury Net-Zero Home by Rockwood Custom Homes 47 Grandview Place, Calgary AB T3Z A8 by Grant Bremner A Net-Zero Emissions (NZE) home is carbon neutral where carbon credits fully offset emissions. An NZE

More information

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES HANIYEH MOHAMMADPOURKARBASI, STEVE SHARPLES School of Architecture, University of Liverpool, Liverpool,

More information

Design Charrette. New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY NYSERDA

Design Charrette. New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY NYSERDA Design Charrette New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY 12203 1-866-NYSERDA Carlos Dachary, PE, LEED-AP Sustainable Performance Consulting September 10,

More information

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001:

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001: Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION to be used in conjunction with MIS 3001: REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION,

More information

Project Report: SunMaxx Commercial Case Studies

Project Report: SunMaxx Commercial Case Studies Project Report: 7 x ThermoPower-VHP30 Total Gross Surface Area: 369.25 sq.ft Azimuth: 10 Incl.: 37 1200 gal/day 120 F Gas Boiler - 9 150 kbtu/hr StorMaxx NP Vol:1500 gal Existing Hot Water Heater Vol:600

More information

Multi-angled façade system for office building renovation Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Gert Michael

Multi-angled façade system for office building renovation Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Gert Michael Aalborg Universitet Multi-angled façade system for office building renovation Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Gert Michael Publication date: 2016 Document Version Publisher's PDF,

More information

Project Report: SunMaxx Commercial Case Studies

Project Report: SunMaxx Commercial Case Studies Project Report: 5 x ThermoPower-VHP30 Total Gross Surface Area: 263.75 sq.ft Azimuth: 10 Incl.: 37 900 gal/day 120 F Gas Boiler - 9 100 kbtu/hr StorMaxx NP Vol:1200 gal Existing Hot Water Heater Vol:400

More information

Combined Heat and Power & District Heating Networks. For the East Midlands

Combined Heat and Power & District Heating Networks. For the East Midlands Combined Heat and Power & District Heating Networks For the East Midlands Introduction to Combined Heat and Power The Basics Systems produce heat & electricity Production of electricity at the point of

More information

TVA Melton Hill Dam Sustainable Recreation Area

TVA Melton Hill Dam Sustainable Recreation Area TVA Melton Hill Dam Sustainable Recreation Area Analysis of 3.75 Years of Field Data (Jan 2012 Sep 2015) Chris Trueblood David Freestate October 23, 2015 TVA Melton Hill Dam Sustainable Recreation Area

More information

Go Green Go Geothermal

Go Green Go Geothermal Go Green Go Geothermal What We ll Cover Today Market Status Current Status Growth Potential System Advantages and Disadvantages Competing Technologies Case Studies Lessons Learned Feasibility of Geothermal

More information

European Cooperation in the field of Scientific and Technical Research. Building Integration of Solar Thermal Systems TU1205 BISTS

European Cooperation in the field of Scientific and Technical Research. Building Integration of Solar Thermal Systems TU1205 BISTS Solar Combi systems Dorota Chwieduk Institute of Heat Engineering, ITC Faculty of Power and Aeronautical Engineering, MEiL Warsaw University oftechnology, PW Availability of solar energy Availability of

More information

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001:

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001: Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION to be used in conjunction with MIS 3001: REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION,

More information

Zero Energy Building Example in Estonia. Tõnu Mauring

Zero Energy Building Example in Estonia. Tõnu Mauring Zero Energy Building Example in Estonia Tõnu Mauring University of Tartu, Estonia Jan 22 2014, Riga Site location Põlva, Estonia (58 N, 27 E) Long-term average dry bulb temperature for inland part of Estonia

More information

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018 NWC District Energy Campus Energy - RFQ Supporting Documentation April 25, 2018 ESTIMATED ENERGY DEMAND BY BUILDING Facility Name Area Energy Use Intensity Goal Estimated Total Energy Total Average Peak

More information

Deep Energy Retrofit of a HighRise MURB

Deep Energy Retrofit of a HighRise MURB Deep Energy Retrofit of a HighRise MURB COLIN SHANE M.Eng., P.Eng. RDH BUILDING SCIENCES INC. SAN FRANCISCO, CA AIA Credits National Institute of Building Sciences Provider #G168 Credit(s) earned on completion

More information

Adaption of the passive house concept in northern Sweden - a case study of performance

Adaption of the passive house concept in northern Sweden - a case study of performance Passivhus Norden 2013 Adaption of the passive house concept in northern Sweden - a case study of performance Itai Danielski, The Department of Ecotechnology and Sustainable Building Engineering, Mid Sweden

More information

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre Amin Moazami, Salvatore Carlucci, Stig Geving Faculty of Engineering Science and Technology Department

More information

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity Energy Accounting & Education Energy Managers Kermit King School District of La Crosse John Daily School District of Holmen 1 Topics (Electricity) Creating electricity Defining degree days Customer charges

More information

Growth drivers in Uponor s businesses Heating and Cooling

Growth drivers in Uponor s businesses Heating and Cooling Growth drivers in Uponor s businesses Heating and Cooling Georg von Graevenitz Executive Vice President, Uponor Nordic Key applications Underfloor Heating (UFH) Complete systems for underfloor heating

More information

THE FRENCH EMBASSY IN TOKYO

THE FRENCH EMBASSY IN TOKYO A PROJECT IN JAPAN DISTINGUISHED FOR ITS COMMITMENT TO SUSTAINABILITY THE FRENCH EMBASSY IN TOKYO - FROM AIRPORT TO EMBASSY: A TROPISM - A STRONG ALLIANCE BETWEEN FRENCH AND JAPANESE COMPANIES: VICINITY

More information

Design and optimization of solar water heating system for a five star hotel in Varanasi

Design and optimization of solar water heating system for a five star hotel in Varanasi Design and optimization of solar water heating system for a five star hotel in Varanasi Mahesh Vipradas & Amit Kumar Tata Energy Research Institute, Darbari Seth Block, Habitat Place, Lodhi Road, New Delhi

More information

Demand side management for smart district heating

Demand side management for smart district heating Downloaded from orbit.dtu.dk on: Jul 06, 2018 Demand side management for smart district heating Big, Oovidiu; Li, Hongwei; Svendsen, Svend Published in: Energy Procedia Publication date: 2016 Document

More information

Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards

Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards Downloaded from orbit.dtu.dk on: Oct 06, 2018 Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards Olesen, Bjarne W.; Langkilde,

More information

THE EUROPEAN ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE: COMPARISON OF CALCULATED AND ACTUAL ENERGY USE IN A DANISH OFFICE BUILDING

THE EUROPEAN ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE: COMPARISON OF CALCULATED AND ACTUAL ENERGY USE IN A DANISH OFFICE BUILDING THE EUROPEAN ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE: COMPARISON OF CALCULATED AND ACTUAL ENERGY USE IN A DANISH OFFICE BUILDING Steffen Petersen 1 and Christian Anker Hviid 2 1 Aarhus University School

More information

GAS FOR HEATING & COOLING. POLICY WORKSHOP 14 June 2016, European Parliament

GAS FOR HEATING & COOLING. POLICY WORKSHOP 14 June 2016, European Parliament GAS FOR HEATING & COOLING POLICY WORKSHOP 14 June 2016, European Parliament 1 Why gas? System considerations for heating & cooling and future opportunities Eva Hennig 14 June 2016 Thüga Partnership Model:

More information

4GDH The newest DH generation. Dr. Oddgeir Gudmundsson Director, Projects Application and Technology Danfoss Heating Segment

4GDH The newest DH generation. Dr. Oddgeir Gudmundsson Director, Projects Application and Technology Danfoss Heating Segment 4GDH The newest DH generation Dr. Oddgeir Gudmundsson Director, Projects Application and Technology Danfoss Heating Segment 1 Danfoss Heating Segment - Application Centre Dr. Oddgeir Gudmundsson - 2016

More information

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur Prashant Bhanware (BEEP) 2 nd REGIONAL WORKSHOP ON ECBC IMPLEMENTATION IN STATES March 15 & 16, 2017 Hyatt, Ahmedabad Outline

More information

Electric Forward Market Report

Electric Forward Market Report Mar-01 Mar-02 Jun-02 Sep-02 Dec-02 Mar-03 Jun-03 Sep-03 Dec-03 Mar-04 Jun-04 Sep-04 Dec-04 Mar-05 May-05 Aug-05 Nov-05 Feb-06 Jun-06 Sep-06 Dec-06 Mar-07 Jun-07 Sep-07 Dec-07 Apr-08 Jun-08 Sep-08 Dec-08

More information

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION URBANSCAPE GREEN ROOF SYSTEMS

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION URBANSCAPE GREEN ROOF SYSTEMS November 215 BREEAM (Building Research Establishment Environmental Assessment Methodology) International New Construction 1 is a voluntary standard that defines high performance green buildings which are

More information

Woking. q business confidence report

Woking. q business confidence report Woking q1 business confidence report Woking q1 report headlines saw a new record in company registrations in Woking when compared to any previous. was a record quarter for company registrations in Woking

More information

District heating topics

District heating topics District heating topics This project has received funding from the European Union s Seventh Framework Programme for research, technological development and demonstration under grant agreement no ENER/FP7/609127/READY

More information

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS A survey on energy consumption status and characteristics of hotel buildings in Guangzhou To cite this article: Yehong Li et al

More information

Energy Audit. Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4

Energy Audit. Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4 Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4 Energy Audit Date: Country: SERBIA Partner: University of Novi Sad (UNS) Building: Health

More information

Future European Heat. Renewable heating comparisons

Future European Heat. Renewable heating comparisons Document number Future European Heat Renewable heating comparisons Tuesday, 28 May 2013 By: Melahn Parker (Melahn.Parker@dnvkema.com) DNV KEMA Energy & Sustainability DNV KEMA serves the entire energy

More information

Optimizing Design for Conversion From Steam to Hot Water

Optimizing Design for Conversion From Steam to Hot Water Optimizing Design for Conversion From Steam to Hot Water Mark Spurr FVB Energy Inc. International District Energy Association Campus Conference March 8, 2018 45 Years of Experience in Sustainable District

More information

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of Renewables Vacuum Tube Solar Systems Solar Energy to the Power of FREE HOT WATER FROM DAWN TO DUSK AND THROUGHOUT THE YEAR WITH Thermomax advanced vacuum tube solar systems provide hot water in all seasons.

More information

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY Qian Li 1, Phil Jones 1, and Simon Lannon 1 Welsh School of Architecture, Cardiff

More information

Feasibility Study. Solar plant with district heating net (Austria)

Feasibility Study. Solar plant with district heating net (Austria) Feasibility Study Solar plant with district heating net (Austria) Elaborated by DI Horst Strießnig DI Philip Ohnewein Graz, October 2006 nahwaerme.at Energiecontracting GmbH & Co KG Herrgottwiesgasse 188

More information

Sustainable Building Façade and Advanced Fenestration Systems

Sustainable Building Façade and Advanced Fenestration Systems Workshop on Potential Technological Developments for Zero Carbon Buildings 16-17 Oct 2013 Sustainable Building Façade and Advanced Fenestration Systems Tin-Tai Chow Building Energy & Environmental Technology

More information

This is the published version of a paper presented at CLIMA 2013, Prague, June 16-19,

This is the published version of a paper presented at CLIMA 2013, Prague, June 16-19, http://www.diva-portal.org This is the published version of a paper presented at CLIMA 2013, Prague, June 16-19, 2013.. Citation for the original published paper: Gustafsson, M., Myhren, J., Bales, C.

More information

Potential of ventilative cooling in German residential buildings

Potential of ventilative cooling in German residential buildings Potential of ventilative cooling in German residential buildings QUALICHeCK-Webinar, 2016-12-01 Auf Wissen bauen Fraunhofer IBP Introduction Background Highly insulated buildings with almost completely

More information

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa Matteo BRASCA *, Oscar Luigi PAGANI **, Kanza RAUF*** * partner - AIACE S.r.l. società di ingegneria, contract

More information

A prototype architecture for passive and plus energy building in Estonia

A prototype architecture for passive and plus energy building in Estonia A prototype architecture for passive and plus energy building in Estonia Tõnu Mauring, Jaanus Hallik, Margus Valge, Kristo Kalbe University of Tartu, Institute of Technology Georg W. Reinberg, Architekturbüro

More information

An investigation into potential of passive solar. features to realise net zero carbon housing

An investigation into potential of passive solar. features to realise net zero carbon housing Department of Mechanical and Aerospace Engineering An investigation into potential of passive solar features to realise net zero carbon housing Author: Swapnil Sunil Kulkarni Supervisor: Professor Joe

More information

BESA HIU test procedure. Martin Crane

BESA HIU test procedure. Martin Crane BESA HIU test procedure Martin Crane Carbon Alternatives After working for a range of consultancies on DH / CHP / renewables / energy efficiency domestic and non-domestic, I spent 8 years at SSE working

More information

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design Proceedings of the 2 nd ICAUD International Conference in Architecture and Urban Design Epoka University, Tirana, Albania, 8- May 14 Paper No. 128 Passive Strategies and Low-Carbon Technologies: Evaluating

More information

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project The participating home is a single family detached home in Hudson, NY. The house was completed and occupied

More information

ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India

ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India Co-presenter: Tarush Chandra, Malaviya National Institute of

More information

Postprint.

Postprint. http://www.diva-portal.org Postprint This is the accepted version of a paper presented at 11th REHVA world congress Clima 2013 - Energy efficient, smart and healthy buildings, Prague, June 16-19, 2013.

More information

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y Nearly zero-energy building and components of the DIRECTIVE on energy performance of buildings 2010/31/EU Albin Zsebik, PhD, CEM Improving university curricula in the areas of a) energy efficiency in the

More information

Danish national plans for Nearly Zero Energy Buildings

Danish national plans for Nearly Zero Energy Buildings Danish national plans for Nearly Zero Energy Buildings ENERGY SEMINAR IN ESPOO 5 NOVEMBER 2014 KIRSTEN ENGELUND THOMSEN DANISH BUILDING RESEARCH INSTITUTE, SBi AALBORG UNIVERSITY COPENHAGEN Agenda Political

More information

Long-term monitoring and smart heat pumps for nzeb

Long-term monitoring and smart heat pumps for nzeb Long-term monitoring and smart heat pumps for nzeb Franziska Bockelmann Christina Betzold Berghalde 1. Monitoring results 2. Optimization: increase of self supply Implementation building Systemsimulation

More information

2017 KEY INSIGHTS ON. Employee Attendance and Tardiness

2017 KEY INSIGHTS ON. Employee Attendance and Tardiness 2017 KEY INSIGHTS ON Employee Attendance and Tardiness THE AVERAGE NUMBER OF MINUTES THAT EMPLOYEES IN THE XIMBLE SYSTEM ARE LATE IS MINUTES. 114.2 MINUTES Statistical sample of 263258 clock-in records,

More information

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES Lusi Susanti 1, Hiroshi Matsumoto 2, and Hiroshi Homma 2 1 Department of

More information

Energy Audit. Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4

Energy Audit. Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4 Project: ENergy Efficiency and Renewables SUPporting Policies in Local level for EnergY (ENER-SUPPLY) Work Package 4 Energy Audit Date: Country: SERBIA Partner: University of Novi Sad (UNS) Building: Pre-school

More information

Modeling and Simulation of Energy Use and Indoor Thermal Environment of Highly-Insulated Buildings

Modeling and Simulation of Energy Use and Indoor Thermal Environment of Highly-Insulated Buildings Modeling and Simulation of Energy Use and Indoor Thermal Environment of Highly-Insulated Buildings Laurent Georges Energy and Process Engineering Department, Norwegian University of Science and Technology

More information

ECOHOUSES - 21 st Century Ideal Buildings Minimal Imported Energy Safe in Extreme Climates Low running Costs

ECOHOUSES - 21 st Century Ideal Buildings Minimal Imported Energy Safe in Extreme Climates Low running Costs ECOHOUSES - 21 st Century Ideal Buildings Minimal Imported Energy Safe in Extreme Climates Low running Costs Susan Roaf, Professor of Architectural Engineering, Heriot Watt University, Edinburgh, s.roaf@hw.ac.uk

More information

Solar heat in Industry and Commerce to cut energy costs and green house gas emissions

Solar heat in Industry and Commerce to cut energy costs and green house gas emissions 1. Introduction 2. Solar Technology 3. Market Overview 4. Ecomomics 5. Outlook Solar heat in Industry and Commerce to cut energy costs and green house gas emissions Dr.-Ing. Bastian Schmitt, University

More information

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

PV Generation Potential 17.1 kbtu/ft2/yr 15.4 TOWNHOME PROTOTYPE BASELINE 60 kbtu/sf/yr 50 kbtu/sf/yr 40 kbtu/sf/yr 30 kbtu/sf/yr 20 kbtu/sf/yr 10 kbtu/sf/yr 0 kbtu/sf/yr 54.4 Baseline 54.4 kbtu/ 2/yr 21.8 High Performance 18.2 PHIUS - IES 60 MMBtu

More information

Solar energy house with brine-water heat pump and PV. Map section

Solar energy house with brine-water heat pump and PV. Map section Project Solar energy house with brine-water heat pump and PV Location of the system Rapperswil SG Longitude: 8.82 Latitude: 47.23 Elevation: 417 m Map section "Current report item is not supported in this

More information

ScienceDirect. Simulation based mixed mode building design

ScienceDirect. Simulation based mixed mode building design Available online at www.sciencedirect.com ScienceDirect Energy Procedia 00 (2016) 000 000 www.elsevier.com/locate/procedia 5th International Conference on Advances in Energy Research, ICAER 2015, 15-17

More information

Citation for the original published paper (version of record):

Citation for the original published paper (version of record): http://www.diva-portal.org This is the published version of a paper published in Energy Procedia. Citation for the original published paper (version of record): Lidberg, T., Swing Gustafsson, M., Myhren,

More information

SURNA Grow Facility: Systems Comparison - IEA

SURNA Grow Facility: Systems Comparison - IEA SURNA Grow Facility: Systems Comparison - IEA May 2016 SURNA Grow Facility This analysis provides the projected energy and associated cost comparison between the Surna proposed facility in comparison to

More information

LOW TEMPERATURE DISTRICT ENERGY SYSTEMS

LOW TEMPERATURE DISTRICT ENERGY SYSTEMS 17 th Building Services, Mechanical and Building Industry Days Urban Energy Conference, 13-14 October 2011, Debrecen, Hungary LOW TEMPERATURE DISTRICT ENERGY SYSTEMS Robin Wiltshire BRE, Bucknalls Lane,

More information

Bringing an energy neutral built environment in the Netherlands under control

Bringing an energy neutral built environment in the Netherlands under control Bringing an energy neutral built environment in the Netherlands under control Ivo Opstelten 1, Ernst-Jan Bakker 1, Josco Kester 1, Wouter Borsboom 2,Bert Elkhuizen 2 1 Energy research Centre of the Netherlands,

More information

AGGREGATION OF BUILDING ENERGY DEMANDS FOR CITY-SCALE MODELS

AGGREGATION OF BUILDING ENERGY DEMANDS FOR CITY-SCALE MODELS AGGREGATION OF BUILDING ENERGY DEMANDS FOR CITY-SCALE MODELS Panagiota Gianniou 1, Alfred Heller 1, Per Sieverts Nielsen 2, Kristoffer Negendahl 1, Carsten Rode 1 1 Department of Civil Engineering, DTU,

More information

Building Envelope Energy Performance

Building Envelope Energy Performance Building Envelope Energy Performance Gustav Nordström PhD Student Luleå University of Technology Sweden Nordic Symposium on Energy Efficiency in Buildings Oulu, Finland, 27 September, 23 Measuring and

More information

SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia

SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia SIMULATION VERSUS REALITY 4 CASE STUDIES Anthony Calderone Aurecon, Melbourne, Australia calderonea@ap.aurecongroup.com ABSTRACT This paper will focus on four completed projects that have gone through

More information

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings Srinivas Katipamula, Ph.D. Staff Scientist, Pacific Northwest National Laboratory Other TAG Members: Irfan Rehmanji

More information

5.5 kwh/m 2 day. Solar Thermal Systems. Solar Water Heater Story in Jordan. Flat plate collectors

5.5 kwh/m 2 day. Solar Thermal Systems. Solar Water Heater Story in Jordan. Flat plate collectors Energy Consumption ( Tones ) Transport 1,822,000 (37%) Industry 1,846,000 (24%) Household 1,064,000 (22% ) Energy Situation in Jordan Energy Resources: Most of Jordan s Energy Requirements are Imported

More information

SOLAR THERMAL IT S HOT AGAIN! Solar Water Heating and Solar Thermal Energy Solutions

SOLAR THERMAL IT S HOT AGAIN! Solar Water Heating and Solar Thermal Energy Solutions SOLAR THERMAL IT S HOT AGAIN! Solar Water Heating and Solar Thermal Energy Solutions Solar Water Heating and Solar Thermal Energy Solutions Bill Guiney Program Manager Renewable Energy Solutions Great

More information

Energy Performance of Buildings Directive and nearly-zero Energy Buildings

Energy Performance of Buildings Directive and nearly-zero Energy Buildings Energy Performance of Buildings Directive and nearly-zero Energy Buildings J.J. BLOEM DG JRC http://ec.europa.eu/dgs/jrc Serving society Stimulating innovation Supporting legislation TOWARDS 2030 Framework

More information