Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

Size: px
Start display at page:

Download "Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:"

Transcription

1 Visit our Web Site HFscientific.com Water Quality Measurement Solutions Online Water Testing Product Sampler 2016 Field Laboratory 3170 Old Metro Parkway Ft. Myers, FL toll free: phone: (239) fax: (239) Information is subject to change without notice. Copyright 2016 by HF scientific. All rights reserved Rev 1 Visit Us at: HFscientific.com

2 NEW!! With over 30 years of optical design expertise HF scientific has developed an AccUView LED Online UV Analyzer specifically for drinking water disinfection monitoring. Engineered using leading edge microprocessor technology, the AccUView LED is the most reliable and cost efficient instrument for monitoring the %Transmission and Absorbance of a UV Disinfection System for drinking water. Standard Features AccUView LED Online UV Analyzer UVC LED light source Longer life and mercury free Two measurement scales %Transmission and Absorbance Communications Standard communications include 4-20 ma with isolator or RS-485 with Modbus protocol. Affordable Modular microprocessor based technology ensures high quality at an affordable price. Certified Standards HF scientific certified 100%T Calibration Standard. Low Maintenance Fail Safe Design Simple Modular Design. Ultrasonic autoclean system reduces time consuming maintenance. AccUView LED Online UV Analyzer with Flow Alarm Model Shown Ultrasonic Autoclean System Keeps the optical chamber clean in finished or raw water applications. Water Quality Visual Test Kits Visual Test Kits provide a quick, portable, and convenient way to measure some of the most common water quality test parameters anywhere at any time. Accurate chemistry, simple to read comparator cards with instruction, and expandable carrying case allows for testing on site without having to take water samples back to a chemistry laboratory. PARAMETER TEST TYPE RANGE (PPM) # TEST Total Iron (Fe+3) Kit Visual Comparator, Colorimetric Ferrous Iron (Fe+2) Kit Visual Comparator, Colorimetric Manganese Kit Visual Comparator, Colorimetric Total Alkalinity Kit Visual Comparator, Colorimetric ph Kit Visual Comparator, Colorimetric Chlorine (Free & Total) Kit Visual Comparator, Colorimetric Total Hardness Kit Visual Drop Count, Titrimetric 0-500/0-30gpg 100 NEW!! Total Alkalinity Pocket Photometer The Total Alkalinity Pocket Photometer gives the accuracy expected from your laboratory, no matter where you happen to be. A reagent set is included that contains chemistry for a minimum of 100 tests, 4 disposable cuvettes, and a syringe for accurate sample volume delivery. Standard Features Laboratory Accuracy in the Field Microprocessor technology together with rugged construction ensures accuracy and durability in the roughest environments. Reagents and Accessories Included Provides everything needed to conduct a test. Simple Operation No need to change cuvette, pathlength, or range for full scale measurements. Waterproof IP-67 at 1m for 30 minutes Methodology Total Alkalinity by colorimetry from mg/l as CaCO3 consuming maintenance. NEW!! Total Alkalinity Pocket Photometer Includes: one reagent set that contains chemistry for a minimum of 100 tests, 4 measuring cuvettes, 4 AAA batteries, and instructions. Ordering Code: 10482

3 UVT-15 UV %Transmission Photometer Designed to provide the accuracy demanded by today s user, the UVT-15 Photometer is ready to meet the challenge. Packaged in a shock resistant carrying case with everything needed for measuring the transmission of a sample, the instrument is convenient and durable regardless of the sampling location. Rugged transportable carrying case Simple calibration initiated with the push of a button Completely self contained with everything needed to measure %Transmission AccUView Wastewater UV %Transmission Analyzer The AccUVIew WASTEWATER is the most reliable and cost effective instrument for monitoring the %Transmission of Wastewater. Standard features include continuous Ultrasonic Autoclean, simple calibration procedures and bellows pump for the sample intake. Continuous ultrasonic autoclean Low maintenance design Certified standards 4-20 ma or optional RS-485 with modbus Chlorine Micro Check Test Strips The Micro Check Test Strips are an accurate, inexpensive and safe alternative to Reagent Chlorine Testing. Quick and Easy to use accurate results are achieved in under one minute. Available in Free or Total chlorine with sensitivity as low as 0.05 PPM (mg/l). DPD Powder Pops DPD Powder Pops are individually packaged doses of reagent used to deliver a measured amount of DPD Reagent to a 5, 10 or 25ml testing sample. Packaged in 200 or 1000 count units they are a convenient way to test for chlorine using HF scientific and other manufacturer's photometers. Test Description Sample Size Use with the following Photometers DPD Powder Pops 5 ml HF scientific, Hach DPD Powder Pops 10 ml Hach, Hanna DPD Powder Pops 25 ml Hach Free chlorine 200 pkg, 5 ml Free chlorine 1000 pkg, 5 ml Total chlorine 200 pkg, 5 ml Total chlorine 1000 pkg, 5 ml Free chlorine 200 pkg, 10 ml Free chlorine 1000 pkg, 10 ml Total chlorine 200 pkg, 10 ml Total chlorine 1000 pkg, 10 ml Free chlorine 200 pkg, 25 ml Free chlorine 1000 pkg, 25 ml Total chlorine 200 pkg, 25 ml Total chlorine 1000 pkg, 25 ml Chloramine powder pop reagent, 200 pkg Bottles of 50 Strips Part # Micro check free* Micro check total* *Detection levels for: Free - 0, 0.1, 0.2, 0.4, 0.6, 0.8, 1.2, 1.5, 2.0, 2.6, 4.0, 6.0, 10 Total - High Range; 0.0, 0.1, 0.2, 0.5, 0.8, 4.0, 10.0 Low Range: 0.0, 0.05, 0.1, 0.15, 0.2, 0.5, 1.0

4 M icro OL OnLine Turbidimeter Leading edge Microelectronic Technology combined with 30 years of optical measurement expertise has allowed HF scientific to become the leader in regulatory reporting turbidimeters. The HF Micro OL OnLine Turbidimeter has been specifically designed to meet regulations of the EPA and ISO 7027 for monitoring turbidity in drinking water. An Ultrasonic Autoclean System, Backlight Display, Signal Averaging, RS-485 with Modbus Protocol are new features that will make the instrument perfect for finished or raw water applications. Range of 0-10, 0-100, and NTU Fast and easy calibration Ultrasonic autoclean system Low maintenance fail safe design RS-485 with modbus protocol USEPA or ISO7027 accepted Signal averaging Inline pressure regulator Cat. No. Micro OL Range in NTU Automatic ultrasonic autoclean system Ultrasonic Autoclean Method ISO #2 White Light #2 Infrared #3 White Light #3 Infrared #4 White Light #4 Infrared #5 White Light #5 Infrared #6 White Light #6 Infrared 0-10 All models include 4-20ma, backlight display, RS-485/Modbus, inline pressure regulator, desiccant, spare measuring cuvette with light shield, universal power supply and manual. PPD-2 Chlorine DPD Reagent Dispenser The patented HF scientific Powder Pop Dispenser delivers a precise dose of DPD reagent directly to the sample with the push of a button. No foil pouches to tear open and no mess to leave behind. Formulated to be compatible with HF and other manufacturer s Photometers. (See Chart below) Test for Free Cl, 5 ml samples 10500C 1000 Test for Free Cl, 5 ml samples (5x200 tests) Tests for Total Cl, 5 ml samples 10502C 1000 Tests for Total Cl, 5 ml samples (5x200 tests) Tests for Free Cl, 10 ml samples 10504C 1000 Tests for Free Cl, 10 ml samples (5x200 tests) Tests for Total Cl, 10 ml samples 10506C 1000 Tests for Total Cl, 10 ml samples (5x200 tests) 10504T *100 Tests for Free Cl, 10 ml samples 10506T *100 Tests for Total Cl, 10 ml samples *For Photometers using Tablet Technology Test Description Sample Size Use with the following Photometers DPD Dispenser 5 ml HF scientific, Hach DPD Dispenser 10 ml Hach, Hanna DPD Dispenser; Tablet Formulation DPD Dispenser 25 ml Hach 10 ml Lamotte, Lovibond, YSI, Palintest, Tintometer, Orion Pocket Photometer for Chlorine Measurement The Chlorine Pocket Photometer, with a range of 0-10 ppm, gives the accuracy expected from the laboratory, no matter where the laboratory happens to be located. When combined with the patented, convenient PPD-2 DPD Powder Pop Dispenser the Chlorine Pocket Photometer is packaged in a self-contained, rugged carrying case that has everything needed to measure Free or Total Chlorine residuals. A model for measuring Chlorine Dioxide residuals is also available and packaged in the same rugged package for convenient storage when not in use Chlorine Pocket Photometer Includes: 4 measuring cuvettes w/caps, 4 AAA batteries, rugged carrying case and instructions Chlorine Dioxide Pocket Photometer Includes: 4 measuring cuvettes w/caps, Powder Pop Dispenser (PPD-2) w/100 doses of DPD, 30ml of Glycine Reagent, 4 AAA batteries, rugged carrying case and instructions.

5 ProCal Primary Turbidity Standards...the Office of Ground Water and Drinking Water s Technical Support Center has concluded that HF scientific s solution is an acceptable equivalent to currently approved primary polymer turbidity standards. EPA, Feb ph electrode storage solution 16 oz Buffer solution, ph 4.00 (1 gal) Buffer solution, ph 4.00 (500 ml) Buffer solution, ph 7.00 (1 gal) Buffer solution, ph 7.00 (500 ml) Buffer solution, ph (1 gal) Buffer solution, ph (500 ml) ph 4 buffer tablets (100/box) ph 7 buffer tablets (100/box) ph10 buffer tablets (100/box) 10124A Greener - safe and non-toxic Two year shelf life Easy to use Custom standards available validation calibration check kits Available for Hach instruments: Hach 1720 C/D/E series Hach 2100P Hach 2100Q Hach 2100N Hach is a registered trademark of the Hach Company, which is not affiliated with HF scientific Acetate buffer (ph 4) for residual analyzers (4 x 1 gallon) Primary Turbidity Standards Hach 2100AN ph Buffers Certified Traceable to NIST Standard M icro 100 Laboratory Turbidimeter Designed to provide the accuracy demanded for laboratory use, the icro 100 Laboratory Turbidimeter is ready to meet the challenge. The Auto Alert Calibration Prompt and the Quick Connection Lamp Module allow for simple calibration and low maintenance. With a resolution of 0.01 NTU at low turbidity readings and an extended range to 1,000 NTU, the M icro 100 is an ideal and affordable tool for research as well as routine analytical measurements. Auto ranging NTU Push-button calibration Optional pour-through assembly Auto alert calibration prompt Quick connection lamp module Available in white light or infrared USEPA or ISO7027 compliant M icro 1000 Laboratory Turbidimeter Our newest addition to our laboratory line takes turbidity measurement further. With a resolution of NTU at low turbidity readings and an extended range to 10,000 NTU along with a full time ratio (color correction) mode, the M icro 1000 is an ideal and affordable tool for research as well as routine analytical measurements. Extended range, 0-10,000 NTU Three measurement modes (NTU, EBC, Nephlos) User selectable ratio mode USEPA or ISO7027 compliant Auto alert calibration prompt Quick connect lamp module Available in white light or infrared Available pour-through and flow-through assemblies Handheld Turbidimeters Designed to provide the ease of portability needed in the field with rugged durability, the is a necessity for anyone monitoring turbidity on the go. The shock-resistant carrying case holds everything necessary for field operation while the instrument itself removes easily to go wherever it is needed. With a resolution of 0.01 NTU and an extended range to 1,100 NTU, the is a perfect partner for field use. Auto ranging 0-1,100 NTU Push-button calibration Extended battery life - powered by 4 - AAA batteries Comes with a rugged high density carrying case The instrument housing is waterproof for added protection white light method infrared ISO7027 M

6 Nitrification Inhibitor Dispenser for CBOD Analysis (carbonaceous biological oxygen demand) The new HF scientific Nitrification Inhibitor Dispenser for CBOD Analysis is a quick, convenient and economical way to dispense chemicals when doing multiple carbonaceous BOD tests. Dispenser is designed to provide an accurate dose of TCMP as outlined in Standard Methods for the Examination of Water and Wastewater, 22nd Ed B. 5-day BOD test. Convenient and easy to use dispenser Dispenser contains enough reagent for 200 standard 300ml BOD bottles Dispenser provides consistent dose: No weighing or measuring needed OnLine Residual Chlorine Monitor The Online Residual Chlorine Monitor is an economical and low maintenance instrument for chemical or industrial processes that require continuous monitoring and control of residual Free or Total Chlorine levels. Unattended operation and low chemical useage equates to low operating and maintenance costs. A 4-20mA output that can be used to control feed pumps and user selectable alarms allow complete manual or automatic control of chlorine dosing. The instrument is housed in a strong, shatterproof case with easy access to all functions and reagents. Free or Total chlorine EPA accepted method Low operating cost Auto ranging 0-10 mg/l Colorimetric DPD chemistry User selectable cycle times-(110 sec - 10 minutes) Drinking water, Wastewater applications and more Dispenser Bottles not included Dose multiple bottles quickly without measuring JAW Chlorine Reagent Sets for Hach CL-17 and HF scientific CLX JUST ADD WATER! Reagent sets are specifically designed by HF scientific for use in the Hach CL17 online Chlorine Analyzer and CLX, and have been proven accurate in side by side studies conducted by HF scientific. Reagents are shipped dry in the bottle. Just add DI water and they are ready for use! Hach is a registered trademark of the Hach Company, which is not affiliated with HF scientific