1 ENERGY EFFICIENT LIGHTING CONTROLLING THE COST OF ENERGY FOR OFFICE, EDUCATIONAL, RETAIL AND INDUSTRIAL ENVIRONMENTS COLUMBIA LIGHTING ENERGY SOLUTIONS

2 COLUMBIA Lighting ENERGY SOLUTIONS: A Strategic Financial Investment CREATECHANGE MAXIMIZES ENERGY SAVINGS AND TAX CREDITS Energy Use 90 Columbia Lighting is developing technology that improves lamps and ballasts, coatings, and devices that control the amount of electricity used. We offer tools and resources to assist our specifiers, customers, and end users to make intelligent energy decisions. Our energy-efficient lighting solutions do much more than preserve the environment. Reducing your energy consumption, lowering your maintenance costs and qualifying for energy-related tax credits boost your bottom line. Energy efficient lighting solutions can help cut lighting costs up to 52% without sacrificing light levels; even more savings is realized when controls are combined. createchange lighting solutions typically pay for themselves in under two years after being installed in new buildings. createchange solutions costs are often recouped in one to three years following installation in a remodel project. If efficient lighting were used throughout the country, the nation s annual demand for electricity would be cut by more than 10%. This would save ratepayers nearly $17 billion in utility bills. Input Watts Input Watts Energy Use W T BF Energy Use 56 Plus BF As of April 2010, more than 60% of U.S. states have energy codes that were written since These new codes set strict limits on the Lighting Power Density (LPD, measured in watts per square foot) allowed and require the use of lighting controls. State Energy Code Status as of April 2010 The energy solutions offered by Columbia Lighting help you leverage incentives like EPAct and utility discounts where available. And reducing the power demand in buildings is the largest consideration when applying for LEED certification. The Energy Policy Act of 2005 (EPAct) establishes a long-range energy policy to combat the nation s growing energy crisis. Effective January 1, 2006 through December 31, 2013, the U.S. government is offering substantial, accelerated tax incentives as a reward for installing or retrofitting energy-efficient lighting, HVAC and/or building envelope technologies in qualifying applications. Lighting, a critical component of energy use today, represents a significant percentage of the average commercial building s electric bill. Energy-efficient upgrades reduce energy consumption and operating costs by 30 to 50% and often pay for themselves within months. Generally, lighting retrofit investments are amortized over the life of the system. One of the most significant benefits of EPAct 2005 is that it allows a larger portion of the capital investment to be depreciated in the first year. The tax deduction must be calculated based on the square footage of the upgraded building: Up to $1.80/sq. ft. for energy-efficient property The October 2003 report developed by California s Sustainable Task Force entitled The Cost and Financial Benefits of Green s finds that a minimal up front investment of about two percent of construction costs typically yields life cycle savings of over 10 times the initial investment. Input Watts ASHRAE /2009 IECC, or equivalent ASH R AE /2006 IECC, or equivalent Older or less stringent than ASHRAE /2003 IECC No statewide code Adoption by county/jurisdiction above state mandated minimum Up to $0.60/sq. ft. each for interior lighting, HVAC/hot water and building envelopes This brochure outlines some of the most popular products from Columbia Lighting Energy Solutions that help you meet EPAct and other energy regulations through the use of efficient lighting. For a more in-depth description of EPAct 2005, ask your Columbia Lighting representative for a copy of our EPAct 2005 brochure Lamp T8 Optimized 4-Lamp T5HO 6-Lamp T5HO 400W MH-Pulse 400W MH-Probe 400W MH-Elec 2 COLUMBIA LIGHTING ENERGY SOLUTIONS Applications Guide 3

3 Office Footcandle calculations were based on 8' 10' mounting centers in a 90' 120' room with 12' ceilings, a 2.5' workplane height, and 80/50/20 reflectances. LDD =.90 and LLD =.95 Today s offices require sophisticated lighting that directs light to fit the customer s requirements, provides IES recommended light levels, and has reduced power consumption in order to meet strict energy codes. EnergyMax Energy Saving The 2-lamp EnergyMax luminaire is a system of tuned components designed to provide the perfect balance between light output and energy conservation. A true parabolic, the EnergyMax parabolic luminaire fills the energy savings void in the still popular parabolic market. Zero Plenum Troffer High Efficiency Architectural Luminaire A truly innovative luminaire, provides full distribution light and offers several aesthetic looks to suit every taste. Its shallow profile and patented telescoping housing simplifies installation even in the most restricted places. Layout Fixture Mounting Height 12' 12' 12' 12' 12' 12' Lamp Type T8 T8 T8 T8 T5 T8 Initial Lamp Lumens Number of Lamps Ballast Factor Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency 69.2% 87.3% 89.1% 74.3% 85.6% 90.0% Maintained Fixture Lumens 4,276 4,175 4,261 3,553 3,535 4,304 Fixture Watts Maintained Fixture Lumens/Watt CRI ( ) Average Maintained Footcandles Number of Fixtures Total Wattage Square footage Watts/ft Annual Hours Annual Energy Costs $4,177 $2,752 $2,752 $2,752 $2,948 $2,752 % Energy Cost N/A 34% 34% 34% 29% 34% Annual Energy N/A $1,425 $1,425 $1,425 $1,229 $1, LPD Below Standard % 46% 46% 46% 42% 46% Maximum /ft 2 $0.00 $0.60 $0.60 $0.60 $0.60 $0.60 Eligible s ( cannot $0.00 $6,480 $6,480 $6,480 $6,480 $6,480 Mandatory (See Standard ) and Mandatory Bi-level switching (See s ) 4 COLUMBIA LIGHTING ENERGY SOLUTIONS Applications Guide 5

4 Educational Footcandle calculations were based on 8' 10' mounting centers in a 30' 30' room with 9' ceilings, a 2.5' workplane height, and 80/50/20 reflectances. LDD =.90 and LLD =.95 Educational institutions are leading the way with utilizing controls and dimming to take advantage of energy savings. EnergyMax Intersect Full Distribution Luminaire The EnergyMax Intersect is a 2-lamp, energy-efficient, louvered luminaire designed to provide full distribution and energy savings in a crisp new look. As with other EnergyMax energy saving products, Intersect s ballast is tuned to provide the perfect balance between light output and energy use. EnergyMax Stratus Energy Saving Architectural Recessed Indirect Luminaire EnergyMax Stratus is a 2-lamp, high efficiency recessed indirect luminaire utilizing a tuned ballast to provide a great light output to energy use story. Its architectural styling is one of the most popular designs for new, upscale applications. Layout Fixture Mounting Height 9' 9' 9' 9' 9' 9' Lamp Type T8 T8 T8 T8 T5 T8 Initial Lamp Lumens Number of Lamps Ballast Factor Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency 69.2% 87.3% 89.1% 74.3% 85.6% 90.0% Maintained Fixture Lumens 4,276 4,175 4,261 3,553 3,535 4,304 Fixture Watts Maintained Fixture Lumens/Watt CRI ( ) Average Maintained Footcandles Number of Fixtures Total Wattage Square footage Watts/ft Annual Hours Annual Energy Costs $371 $245 $245 $245 $262 $245 % Energy Cost N/A 34% 34% 34% 29% 34% Annual Energy N/A $127 $127 $127 $109 $ LPD Below Standard % 50% 50% 50% 47% 50% Maximum /ft 2 $0.00 $0.60 $0.60 $0.60 $0.60 $0.60 Eligible s ( cannot $0.00 $540 $540 $540 $540 $540 Mandatory (See Standard ) and Mandatory Bi-level switching (See s ) 6 COLUMBIA LIGHTING ENERGY SOLUTIONS Applications Guide 7

5 Retail Footcandle calculations were based on 8' 10' mounting centers in a 300' 300' room with 12' ceilings, a 0' workplane height, and 80/50/20 reflectances. LDD =.90 and LLD =.95 Retail establishments look for lighting that properly illuminates their products and provide a stylish look in the ceiling. e poc Full Distribution Luminaire Characterized by clean lines, low contrast luminance, and heightened attention to energy reduction and sustainability, e poc is a full distribution luminaire in a 2-lamp lensed package. Available in both T5 and T8, e poc incorporates a multitude of lamp/ballast combinations and controls compatibility. e poc also offers a choice of optical aesthetics and an ease of serviceability that is unmatched. Layout Fixture Mounting Height 12' 12' 12' 12' 12' 12' Lamp Type T8 T8 T8 T8 T5 T8 Initial Lamp Lumens Number of Lamps Ballast Factor Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency 69.2% 87.3% 89.1% 74.3% 85.6% 90.0% Maintained Fixture Lumens 4,131 4,032 4,115 3,432 3,415 4,157 Fixture Watts Maintained Fixture Lumens/Watt CRI ( ) Average Maintained Footcandles Number of Fixtures Total Wattage Square footage Watts/ft Annual Hours Annual Energy Costs $34,343 $22,626 $22,626 $22,626 $24,242 $22,626 % Energy Cost N/A 34% 34% 34% 29% 34% Annual Energy N/A $11,717 $11,717 $11,717 $10,101 $11, LPD Below Standard % 64% 64% 64% 61% 64% Maximum /ft 2 $0.00 $0.60 $0.60 $0.60 $0.60 $0.60 Eligible s ( cannot $0.00 $54,000 $54,000 $54,000 $54,000 $54,000 Mandatory (See Standard ) and Mandatory Bi-level switching (See s ) 8 COLUMBIA LIGHTING ENERGY SOLUTIONS Applications Guide 9

6 Industrial Footcandle calculations were based on 25' 22.5' mounting centers in a 500' 400' room with 30' ceilings, a 0' workplane height, and 50/30/10 reflectances. LDD =.85 and LLD =.95 Industrial applications call for quality lighting and energy savings. Linear fluorescent satisfies both of these criteria. VersaBay Fluorescent High Bay VersaBay Fluorescent High Bays can provide energy savings of more than 50%. Carrying an unequaled ballast warranty of 5 years at 65 C for T5HO and 55 C for T8 (277V), VersaBay addresses the issues of elevated temperature with Advanced Thermal Management that properly dissipates and controls heat. Occupancy sensor simply snaps onto standard VersaBay fixtures. With plug and play wiring, installation is tool-free. 400W MH 6-Lamp T8 4-Lamp T5HO 6-Lamp T5HO 8-Lamp T8 8-Lamp T5HO Layout Fixture Mounting Height 25' 25' 25' 25' 25' 25' Lamp Type HID T8 T5HO T5HO T8 T5HO Initial Lamp Lumens Number of Lamps Ballast Factor Lamp Lumen Depreciation Luminaire Dirt Depreciation Fixture Efficiency 80.0% 94.1% 99.2% 99.9% 91.1% 99.7% Maintained Fixture Lumens 15,470 15,063 14,259 21,539 19,444 28,661 Fixture Watts Maintained Fixture Lumens/Watt CRI ( ) Average Maintained Footcandles Number of Fixtures Total Wattage Square footage Watts/ft Annual Hours Annual Energy Costs $93,001 $44,074 $46,298 $69,953 $61,664 $87,340 % Energy Cost N/A 53% 50% 25% 34% 6% Annual Energy N/A $48,927 $46,703 $23,048 $31,337 $5, LPD Below Standard % 82% 81% 72% 75% 65% Maximum /ft 2 $0.00 $0.60 $0.60 $0.60 $0.60 $0.60 Eligible s ( cannot $0.00 $120,000 $120,000 $120,000 $120,000 $120,000 Mandatory (See Standard ) and Mandatory Bi-level switching (See s ) 10 COLUMBIA LIGHTING ENERGY SOLUTIONS Applications Guide 11

7 80% BIL Bi-Level Luminaire 3-lamp fixture designed to maximize energy savings in low occupancy areas such as stairwells and storerooms. EnergyMax Intersect Full Distribution Luminaire 2-lamp, energy efficient, louvered luminaire designed to provide full distribution and tremendous energy savings. EnergyMax Stratus Energy Saving Architectural Recessed Indirect Luminaire 2-lamp, energy efficient, recessed indirect luminaire tuned to meet strict Lighting Power Density requirements. EnergyMax Energy Saving A system of tuned components designed to provide the perfect balance between light output and energy conservation. e poc Full Distribution Luminaire 2-lamp, energy efficient, lensed luminaire with contemporary styling, full distribution, and huge energy savings. VersaBay Fluorescent High Bay The new industry standard for fluorescent high bay lighting with Advanced Thermal Management. MB/MC Morph Fluorescent Exterior Area Lights T5HO luminaires with unprecedented energy savings and light control. RKT/ RKS/ RKSR XFSW XTS RKT/RKS/RKSR Troffer and Industrial Striplight Retrofit Kits Retrofit kits to update existing lighting to meet today s lighting needs and lower energy costs. XFSW Severe Fiberglass Low/High Bay A 4- or 6-lamp IP67 Rated, NSF Rated, and 5VA fire rated low/high bay ideal for cold temperatures. XTS Enclosed and Gasketed Acrylic Tube, Severe Environment 2-lamp, energy-efficient, enclosed and gasketed lighting suitable for wet locations. Zero Plenum Troffer High Efficiency Architectural Luminaire High performance, ultra-low profile luminaire that significantly reduces energy costs. 701 Millennium Blvd. Greenville, SC Tel Fax CO1041 4/10 Copyright 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. All rights reserved. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. Cert no. SW-COC Printed on mixed fiber paper (20% well-managed forests, 80% post consumer).