SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner Concentrate

Size: px
Start display at page:

Download "SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner Concentrate"

Transcription

1 1. PRODUCT AND COMPANY IDENTIFICATION Product information Product name : SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner Recommended use : This product is intended to be diluted prior to use. Manufacturer, importer, supplier : S.C. Johnson & Son, Inc Howe Street Racine WI Telephone : Emergency telephone number : 24 Hour Medical Emergency Phone: (866) Hour International Emergency Phone: (703) Hour Transport Emergency Phone: (800) HAZARDS IDENTIFICATION Classification of the substance or mixture Globally Harmonized System (GHS) Classification Hazard classification Hazard category Hazards identification Skin corrosion Category 1 Causes severe skin burns and eye damage. Serious eye damage Category 1 Causes serious eye damage. Labelling Hazard symbols Corrosion Signal word Danger Hazard statements Causes severe skin burns and eye damage. Precautionary statements If medical advice is needed, have product container or label at hand. Keep out of reach of children. 1/15

2 Read label before use. Immediately call a POISON CENTER or doctor/ physician. Specific treatment (see supplemental first aid instructions on this label). IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. IF ON SKIN (or hair): Remove/ Take off immediately all contaminated clothing. Rinse skin with water/ shower. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. Wash contaminated clothing before reuse. Store locked up. Dispose of contents/ container to an approved incineration plant. Wear protective gloves. Do not breathe dust or mist. Wash hands thoroughly after handling. Other hazards : None identified 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical Name CAS-No. Weight percent Dipropylene glycol methyl Propylene glycol monobutyl Isopropanolamine Secondary ethoxylated alcohol Sodium lauryl sulfate Fatty alcohol alkoxylate EO= The specific chemical identity and/or exact percentage (concentration) of this composition has been withheld as a trade secret. For additional information on product ingredients, see 4. FIRST AID MEASURES Eye contact : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/ physician. Get medical attention immediately. 2/15

3 Skin contact : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. Immediately call a POISON CENTER or doctor/ physician. Inhalation : IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Ingestion : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. 5. FIREFIGHTING MEASURES Suitable extinguishing media Specific hazards during firefighting : Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. : Container may melt and leak in heat of fire. Further information : Wear full protective clothing and positive pressure selfcontained breathing apparatus. In case of fire and/or explosion do not breathe fumes. 6. ACCIDENTAL RELEASE MEASURES Personal precautions : Wear personal protective equipment. Wash thoroughly after handling. Environmental precautions Methods and materials for containment and cleaning up : Outside of normal use, avoid release to the environment. : Dike large spills. Clean residue from spill site. 7. HANDLING AND STORAGE Handling 3/15

4 Precautions for safe handling Advice on protection against fire and explosion Storage Requirements for storage areas and containers : Avoid contact with skin, eyes and clothing. For personal protection see section 8. Use only as directed. KEEP OUT OF REACH OF CHILDREN AND PETS. Avoid breathing vapours, mist or gas. Wash thoroughly after handling. : Normal measures for preventive fire protection. : Keep container closed when not in use. Store locked up. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Occupational Exposure Limits Components CAS-No. mg/m3 ppm Nonstandard Basis units Dipropylene glycol mg/m3 100 ppm - OSHA TWA methyl Dipropylene glycol methyl ppm - ACGIH STEL Dipropylene glycol methyl ppm - ACGIH TWA Personal protective equipment Respiratory protection : Substantial amounts of mist/vapors can be controlled with local exhaust ventilation or respiratory protection. Hand protection : Rubber gloves Eye protection : Wear splash-resistant Chemical goggles. Skin and body protection : Protective footwear. 4/15

5 Hygiene measures : Handle in accordance with good industrial hygiene and safety practice. Wash thoroughly after handling. 9. PHYSICAL AND CHEMICAL PROPERTIES Form : liquid Color : colourless Odor : floral Odour Threshold ph : 11.6 (undiluted) Melting point/freezing point Initial boiling point and boiling range Flash point : 0 C : > 95 C > 203 F Approximate Evaporation rate Flammability (solid, gas) : Does not sustain combustion. Upper/lower flammability or explosive limits Vapour pressure 5/15

6 Vapour density Relative density Solubility(ies) : g/cm3 : soluble Partition coefficient: n- octanol/water Auto-ignition temperature Decomposition temperature Viscosity, dynamic : 4.2 mpa.s Viscosity, kinematic Oxidizing properties Volatile Organic Compounds Total VOC (wt. %)* : 16.6 % - additional exemptions may apply *as defined by US Federal and State Consumer Product Regulations Other information : None identified : 10. STABILITY AND REACTIVITY Possibility of hazardous reactions Possibility of hazardous : Stable under normal conditions. : If accidental mixing occurs and toxic gas is formed, exit area 6/15

7 reactions immediately. Do not return until well ventilated. Conditions to avoid : Direct sources of heat. Incompatible materials : Do not mix with bleach or any other household cleaners. Strong bases Hazardous decomposition products : Thermal decomposition can lead to release of irritating gases and vapours. 11. TOXICOLOGICAL INFORMATION Emergency Overview : Danger Acute oral toxicity : LD50 > 5000 mg/kg Acute inhalation toxicity : LC50 > 10 mg/l Acute dermal toxicity : LD50 > 5000 mg/kg GHS Properties Classification Routes of entry Acute toxicity No classification proposed Oral Acute toxicity No classification proposed Dermal Acute toxicity No classification proposed Inhalation - Dust and Mist Acute toxicity No classification proposed Inhalation - Vapour Acute toxicity No classification proposed Inhalation - Gas Skin corrosion Category 1 - Serious eye damage Category 1 - Skin sensitisation No classification proposed - 7/15

8 Respiratory No classification proposed - sensitisation Germ cell mutagenicity No classification proposed - Carcinogenicity No classification proposed - Reproductive toxicity No classification proposed - Specific target organ No classification proposed - toxicity - single exposure Specific target organ No classification proposed - toxicity - repeated exposure Aspiration hazard No classification proposed - Aggravated Medical Condition : None known. 12. ECOLOGICAL INFORMATION Product : The product itself has not been tested. Toxicity The ingredients in this formula have been reviewed and no adverse impact to the environment is expected when used according to label directions. Toxicity to fish Components End point Species Value Exposure time 96 h Dipropylene glycol methyl static test LC50 Poecilia reticulata (guppy) > 1,000 mg/l Propylene glycol monobutyl static test LC50 Poecilia reticulata (guppy) > 560-1,000 mg/l 96 h 8/15

9 Isopropanolamine static test LC50 Leuciscus idus (Golden orfe) 215 mg/l 96 h Secondary ethoxylated alcohol LC50 Pimephales promelas (fathead minnow) mg/l 96 h Sodium lauryl sulfate No data available Fatty alcohol alkoxylate EO=7 LC50 Danio rerio (zebra fish) mg/l 96 h Toxicity to aquatic invertebrates Components End point Species Value Exposure time 1,919 mg/l 48 h Dipropylene glycol methyl static test LC50 Daphnia magna (Water flea) Propylene glycol monobutyl static test EC50 Daphnia magna (Water flea) > 1,000 mg/l 48 h Isopropanolamine static test EC50 Daphnia magna (Water flea) mg/l 48 h 9/15

10 Secondary ethoxylated alcohol EC50 Daphnia magna (Water flea) 8.7 mg/l 48 h Sodium lauryl sulfate EC50 Daphnia magna (Water flea) mg/l 48 h Fatty alcohol alkoxylate EO=7 EC50 Daphnia (water flea) mg/l 48 h Toxicity to aquatic plants Components End point Species Value Exposure time EC mg/l 72 h Dipropylene glycol methyl Pseudokirchneriella subcapitata (green algae) Propylene glycol monobutyl EC50 Pseudokirchneriella subcapitata (green algae) > 1,000 mg/l 72 h Isopropanolamine static test EC50 Desmodesmus subspicatus (green algae) 32.7 mg/l 72 h Secondary ethoxylated alcohol No data available Sodium lauryl sulfate No data available Fatty alcohol alkoxylate EO=7 EC50 Scenedesmus quadricauda (Green algae) mg/l 72 h 10/15

11 Persistence and degradability Component Biodegradation Exposure Summary time Dipropylene glycol methyl 96 % 28 d Readily biodegradable Propylene glycol monobutyl 90 % 28 d Readily biodegradable Isopropanolamine >= 78 % 28 d Readily biodegradable Secondary ethoxylated alcohol > 60 % 28 d Readily biodegradable Sodium lauryl sulfate 60 % 28 d Readily biodegradable Fatty alcohol alkoxylate EO=7 > 60 % 28 d Readily biodegradable Bioaccumulative potential Component Bioconcentration factor (BCF) Partition Coefficient n- Octanol/water (log) Dipropylene glycol methyl < 100 Calculated Propylene glycol monobutyl 3.2 estimated 1.2 Measured Isopropanolamine 0.11 estimated Secondary ethoxylated alcohol 17 estimated 2.39 estimated Sodium lauryl sulfate No data available No data available Fatty alcohol alkoxylate EO=7 No data available No data available 11/15

12 Mobility Component End point Value Dipropylene glycol methyl No data available Propylene glycol monobutyl Koc Isopropanolamine Koc 1.8 estimated Secondary ethoxylated alcohol No data available Sodium lauryl sulfate No data available Fatty alcohol alkoxylate EO=7 No data available - PBT and vpvb assessment Component Dipropylene glycol methyl Propylene glycol monobutyl Isopropanolamine Secondary ethoxylated alcohol Sodium lauryl sulfate Fatty alcohol alkoxylate EO=7 Results Not fulfilling PBT and vpvb criteria Not fulfilling PBT and vpvb criteria Fulfilling PBT and vpvb criteria Not fulfilling PBT and vpvb criteria Not fulfilling PBT and vpvb criteria Not fulfilling PBT and vpvb criteria Other adverse effects : None known. 13. DISPOSAL CONSIDERATIONS Consumer may discard empty container in trash, or recycle where facilities exist. 12/15

13 14. TRANSPORT INFORMATION Please refer to the Bill of Lading/receiving documents for up-to-date shipping information. Land transport Sea transport Air transport UN number UN proper shipping name UN 3267 Corrosive Liquid, Basic, Organic, N.O.S. (Isopropanolamine), 8, III UN 3267 Corrosive Liquid, Basic, Organic, N.O.S. (Isopropanolamine), 8, III UN 3267 Corrosive Liquid, Basic, Organic, N.O.S. (Isopropanolamine), 8, III Transport hazard class(es) Packing group III III III Environmental hazards Special precautions for user 15. REGULATORY INFORMATION Limited quantities derogation may be applicable to this product, please check transport documents. Limited quantities derogation may be applicable to this product, please check transport documents. Limited quantities derogation may be applicable to this product, please check transport documents. Notification status : All ingredients of this product are listed or are excluded from listing on the U.S. Toxic Substances Control Act (TSCA) Chemical Substance Inventory. California Prop. 65 : This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm. State Right To Know Massachusetts RTK Dipropylene glycol methyl Isopropanolamine Minnesota HSL Dipropylene glycol methyl Propylene glycol /15

14 New Jersey HRTK Dipropylene glycol methyl Isopropanolamine Propylene glycol Pennsylvania RTKL Water Dipropylene glycol methyl Propylene glycol monobutyl Isopropanolamine Propylene glycol Sodium sulfate OTHER INFORMATION HMIS Ratings Health 3 Flammability 1 Reactivity 0 NFPA Ratings Health 3 Fire 1 Reactivity 0 Special - This information is being provided in accordance with the Occupational Safety and Health Administration (OSHA) regulation (29 CFR ). The information supplied is designed for workplaces where product use and frequency of exposure exceeds that established for the labeled consumer use. Further information 14/15

15 This document has been prepared using data from sources considered to be technically reliable. It does not constitute a warranty, expressed or implied, as to the accuracy of the information contained herein. Actual conditions of use are beyond the seller's control. User is responsible to evaluate all available information when using product for any particular use and to comply with all Federal, State, Provincial and Local laws and regulations. Prepared by SC Johnson Global Safety Assessment & Regulatory Affairs (GSARA) 15/15

16 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number PRODUCT AND COMPANY IDENTIFICATION Product information Product name : SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Recommended use : Hard Surface Cleaner Manufacturer, importer, supplier : S.C. Johnson & Son, Inc Howe Street Racine WI Telephone : Emergency telephone number : 24 Hour Medical Emergency Phone: (866) Hour International Emergency Phone: (703) Hour Transport Emergency Phone: (800) HAZARDS IDENTIFICATION Classification of the substance or mixture Globally Harmonized System (GHS) Classification This product does not meet the criteria for classification in any hazard class according to regulation OSHA 29 CFR Labelling Precautionary statements Other hazards : None identified 3. COMPOSITION/INFORMATION ON INGREDIENTS This product does not contain hazardous chemicals at or above a reportable level as defined by OSHA 29 CFR For additional information on product ingredients, see 1/9

17 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number FIRST AID MEASURES Eye contact : No special requirements Skin contact : No special requirements Inhalation : No special requirements. Ingestion : No special requirements 5. FIREFIGHTING MEASURES Suitable extinguishing media Specific hazards during firefighting : Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. : Container may melt and leak in heat of fire. Further information : Fight fire with normal precautions from a reasonable distance. Standard procedure for chemical fires. Wear full protective clothing and positive pressure self-contained breathing apparatus. 6. ACCIDENTAL RELEASE MEASURES Personal precautions : Wash thoroughly after handling. Environmental precautions Methods and materials for containment and cleaning up : Outside of normal use, avoid release to the environment. : Dike large spills. Clean residue from spill site. 2/9

18 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number HANDLING AND STORAGE Handling Precautions for safe handling Advice on protection against fire and explosion Storage Requirements for storage areas and containers : Avoid contact with skin, eyes and clothing. For personal protection see section 8. KEEP OUT OF REACH OF CHILDREN AND PETS. : Normal measures for preventive fire protection. : Keep container closed when not in use. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Occupational Exposure Limits ACGIH or OSHA exposure limits have not been established for this product or reportable ingredients unless noted in the table above. Personal protective equipment Respiratory protection : No special requirements. Hand protection : No special requirements. Eye protection : No special requirements. Skin and body protection : No special requirements. Hygiene measures : Handle in accordance with good industrial hygiene and safety practice. Wash thoroughly after handling. 9. PHYSICAL AND CHEMICAL PROPERTIES Form : liquid 3/9

19 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number Color : colourless Odor : floral Odour Threshold ph : 10.5 Melting point/freezing point Initial boiling point and boiling range Flash point : 0 C : > 95 C > 203 F Approximate Evaporation rate Flammability (solid, gas) : Does not sustain combustion. Upper/lower flammability or explosive limits Vapour pressure Vapour density Relative density : 1 g/cm3 estimated Solubility(ies) : soluble 4/9

20 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number Partition coefficient: n- octanol/water Auto-ignition temperature Decomposition temperature Viscosity, dynamic : similar to water Viscosity, kinematic : similar to water Oxidizing properties Other information : None identified : 10. STABILITY AND REACTIVITY Possibility of hazardous reactions : Stable under normal conditions., If accidental mixing occurs and toxic gas is formed, exit area immediately. Do not return until well ventilated. Conditions to avoid : Direct sources of heat. Incompatible materials : Do not mix with bleach or any other household cleaners. Strong bases Hazardous decomposition : Thermal decomposition can lead to release of irritating gases 5/9

21 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number products and vapours. 11. TOXICOLOGICAL INFORMATION Emergency Overview : This product does not meet the criteria for classification in any hazard class according to regulation OSHA 29 CFR Acute oral toxicity : LD50 > 5000 mg/kg Acute inhalation toxicity : LC50 > 10 mg/l Acute dermal toxicity : LD50 > 5000 mg/kg GHS Properties Classification Routes of entry Acute toxicity No classification proposed Oral Acute toxicity No classification proposed Dermal Acute toxicity No classification proposed Inhalation - Dust and Mist Acute toxicity No classification proposed Inhalation - Vapour Acute toxicity No classification proposed Inhalation - Gas Skin corrosion/irritation No classification proposed - Serious eye No classification proposed - damage/eye irritation Skin sensitisation No classification proposed - Respiratory No classification proposed - sensitisation Germ cell mutagenicity No classification proposed - Carcinogenicity No classification proposed - Reproductive toxicity No classification proposed - 6/9

22 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number Specific target organ No classification proposed - toxicity - single exposure Specific target organ No classification proposed - toxicity - repeated exposure Aspiration hazard No classification proposed - Aggravated Medical Condition : None known. 12. ECOLOGICAL INFORMATION Product : The product itself has not been tested. Toxicity The ingredients in this formula have been reviewed and no adverse impact to the environment is expected when used according to label directions. No environmental data required. Other adverse effects : None known. 13. DISPOSAL CONSIDERATIONS Consumer may discard empty container in trash, or recycle where facilities exist. 7/9

23 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number TRANSPORT INFORMATION Please refer to the Bill of Lading/receiving documents for up-to-date shipping information. UN number UN proper shipping name Transport hazard class(es) Packing group Environmental hazards Special precautions for user Land transport Sea transport Air transport Limited quantities derogation may be applicable to this product, please check transport documents. - - Limited quantities derogation may be applicable to this product, please check transport documents. Limited quantities derogation may be applicable to this product, please check transport documents. 15. REGULATORY INFORMATION Notification status : All ingredients of this product are listed or are excluded from listing on the U.S. Toxic Substances Control Act (TSCA) Chemical Substance Inventory. California Prop. 65 : This product is not subject to the reporting requirements under California's Proposition 65. 8/9

24 SC Johnson Professional TruShot Non-Ammoniated Glass Cleaner End Use Dilution Version 1.0 Print Date 11/17/2016 Revision Date 11/16/2016 SDS Number GEN_SOF Number OTHER INFORMATION HMIS Ratings Health 0 Flammability 0 Reactivity 0 NFPA Ratings Health 0 Fire 0 Reactivity 0 Special - This information is being provided in accordance with the Occupational Safety and Health Administration (OSHA) regulation (29 CFR ). The information supplied is designed for workplaces where product use and frequency of exposure exceeds that established for the labeled consumer use. Further information This document has been prepared using data from sources considered to be technically reliable. It does not constitute a warranty, expressed or implied, as to the accuracy of the information contained herein. Actual conditions of use are beyond the seller's control. User is responsible to evaluate all available information when using product for any particular use and to comply with all Federal, State, Provincial and Local laws and regulations. Prepared by SC Johnson Global Safety Assessment & Regulatory Affairs (GSARA) 9/9