1 Testing Laboratory is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing and calibration laboratories EXOVA LIMITED- Laboratory Issue No:03 Issue Date: Address. Exova Ltd (Abu Dhabi) Plot 25 Old Airport Road Umm Al Naar (Sas Al Nakhl) PO Box 9191 Abu Dhabi United Arab Emirates Contact: Ms. Jeneiliza Gayoba Tel: Fax: jeneiliza.gayoba@exova.com Web Address: Locations where testing activities covered by the above Accreditation Standard are undertaken 1- address: Exova Ltd (Abu Dhabi) Plot 25 Old Airport Road Umm Al Naar (Sas Al Nakhl) PO Box 9191 Abu Dhabi United Arab Emirates For the following scope: Version: 2 Page 1 of 5

2 Scope: 7. Chemical Testing: 7.01 Metals and alloys 7.65 Air 13. Mechanical Testing Metals and metal products Scope details are as follows: Version: 2 Page 2 of 5

3 TEST CATEGORY ITEMS, MATERIALS SPECIFIC TESTS SPECIFICATION, STANDARD METHOD OR PRODUCTS TESTED OR PROPERTIES MEASURED OR TECHNIQUE USED Bend Test of Steel-Ribbed Bars Standard Methods used: BS 4449:1988 and ASTM A615/A615M:2016 Mechanical Testing Carbon Steel Ribbed Bars for the Reinforcement of Concrete ReBend Test of Steel-Ribbed Bars Tensile Test of Steel-Ribbed Bars for Concrete Reinforcement Plain carbon, low alloy and stainless steels Rib Measurement of Steel-Ribbed Bars (Projected Rib Area Calculation) Elemental analysis- P, S, C, Mo, Co, Ni, Fe, Cr, Si, Mn, Nb, Al, V, Ti, Cu, N Total Particulate Matter - Sampling and In-house procedure EX-M-OP-CH-AUH-MD101 In-house procedure EX-M-OP-SA- -MD003 based on BS EN :2002 and US EPA Method 5 PAHs - Sampling and In-house procedure EX-M-OP-SA- -MD003 based on BS ISO :2003 and US EPA Method 5 Chemical Testing Dioxins, Furans and PCB- Sampling and In-house procedure EX-M-OP-SA- -MD003 based on US EPA Method 23, BS EN :2006 Heavy metals- As, Be, Cd, Co, Cr, Cr(vi), Cu, Fe, Hg, K, Mg, Mn, Na, Ni, Pb, Mo, Se, V, Zn- Sampling and In-house procedure EX-M-OP-SA- -MD003 based on US EPA Method 29, BS EN Hydrogen Chloride- Sampling and In-house procedure EX-M-OP-SA- -MD003 based on US EPA Method 26A, BS EN Hydrogen fluoride- Sampling and In-house procedure EX-M-OP-SA- MD003 based on US EPA Method 13B, US EPA Method 26A Version: 2 Page 3 of 5

4 Hydrogen Sulphide- Sampling and Hydrogen Cyanide- Sampling and Ammonia-Sampling and Sulphur dioxide (Wet Chemistry)-Sampling and Sulphur dioxide - Sampling and Carbon monoxide-- Sampling and Carbon dioxide-- Sampling and Oxides of Nitrogen(as NO2)- - Sampling and Oxygen-Sampling and VOCs-- Sampling and In-house procedure EX-M-OP-SA- MD003 based on US EPA Method 11 In-house procedure EX-M-OP-SA- MD003 based on US EPA CT 29 In-house procedure EX-M-OP-SA- MD003 based on BS EN 14791:2005, US EPA CTM 27:1997 In-house procedure EX-M-OP-SA- MD003 based on US EPA Method 6, BS EN 14791:2005 In-house procedure EX-M-OP-SA- MD001 based on US EPA Method 6C In-house procedure EX-M-OP-SA- MD001 based on US EPA Method 10, BS EN 15058:2006 In-house method- EX-M-OP-SA-MD001 based on US EPA Method 3A In-house method- EX-M-OP-SA-MD001 based on US EPA Method 7E and BS EN 14792:2005 In-house method- EX-M-OP-SA-MD001 based on US EPA Method 3A In-house method- EX-M-OP-SA-MD002 based on US EPA Method 25 A using onsite FID instrument In-house method- EX-M-OP-SA-MD022 based on Gas Research Institute method GRI Sulphur Dioxide, Carbon monoxide, Oxides of 96/008 Rev.7 and EMC Conditional test method(ctm) 30 :1997 Nitrogen (as NO2), Oxygen- Sampling and Monitoring Version: 2 Page 4 of 5

5 Ambient Air Quality/ Ambient environment Ambient Air Quality/ Ambient Atmosphere Ambient Environment/ Workplace Carbon monoxide, Nitric oxide, Oxides of Nitrogen(NO/NO2), Sulphur Dioxide, Ozone- Sampling and TSP, PM1, PM2.5, PM10- Sampling and Noise -Sampling and In-house method- EX-M-OP-AA-MD002, Using AQMesh Analyzer In-house method- EX-M-OP-AA-MD003, Using an Osiris Analyzer In-house method- EX-M-OP-NO-MD001, Using Sound level meter END EXOVA Limited Laboratory is recorded as issuing accredited reports to organizations in the countries listed below. This list is current at the time of issue of this schedule. United Arab Emirates Bahrain Saudi Arabia Oman Qatar Kuwait Yemen Version: 2 Page 5 of 5