VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM (ReCAP)

Size: px
Start display at page:

Download "VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM (ReCAP)"

Transcription

1 VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM (ReCAP) Performance Convenience Safety

2 VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM (ReCAP) Built on the foundation of supply chain innovation, VWR s Returnable Container Advantage Program (ReCAP) reliably delivers performance, convenience, and safety for your high-purity solvents. The program starts with your choice of sealed, pressurized 200L stainless steel containers, filled with BDH high-purity Acetonitrile or Methanol (choose your specification). Once at your facility, solvent can be safely dispensed without risking product contamination, spillage, or personal exposure. When the container is almost empty, let us know and we will replace it with a full one so your work remains uninterrupted. Optional accessories, such as liquid-level sensors, are also available Inert gas pressurizes container to smoothly dispense high-purity solvent High-quality and safety with 304 stainless steel Tamper-evident seal for peace of mind Relief valve for pressure regulation Convenience of Swagelok Quick-Connects Serialized containers for precise tracking Integrated fork channels for hassle-free transport 2 VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL

3 FEATURES & BENEFITS PERFORMANCE CONVENIENCE SAFETY Your facility thrives off these vital factors, and with VWR ReCAP, you optimize all three in one simple solution. PERFORMANCE: Product purity meets our highly competitive specifications Choice of market-leading product quality that will match your requirements Sealed system reduces potential for contamination High-quality stainless steel container and fittings allow simple, clean solvent control Dedicated containers help maintain consistent quality approximately 200 lbs of glass, cardboard, and protective inserts are eliminated by each 200L container CONVENIENCE: Reusability eliminates waste Consumes 50% less storage space than the same volume in 4L bottles No expenses due to hazardous packaging disposal Inert gas pressurized operation SAFETY: Container choice available with additional safety and convenience features Reduced personal exposure to flammable or harmful vapors Relief valve to prevent explosions due to pressure changes Improved fire resistance Exclusive Double-Wall Container Features and Benefits: Innovative double-wall, stainless steel construction protects the inner vessel and provides secondary containment in the event of an inner leak Insulation reduces pressure build-up during a fire by up to 90% Split knuckle allows better access for inspection and cleaning Multiple mobility options Dual pressure-relief valves for additional safety FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM 3

4 SPECIFICATIONS FOR ACETONITRILE FAMILY VWR Range of Returnable Containers Description Standard Containers Cat. No. Double-Wall Containers Cat. No. Acetonitrile HiPerSolv CHROMANORM Super Gradient for HPLC BDH BDH Acetonitrile HiPerSolv CHROMANORM LC-MS BDH BDH Acetonitrile HiPerSolv CHROMANORM Ultra LC-MS BDH BDH Acetonitrile HiPerSolv Ultra Low Water for Biopharma BDH BDH Acetonitrile for DNA Synthesis BDH BDH Methanol HiPerSolv CHROMANORM Gradient for HPLC BDH BDH Methanol HiPerSolv CHROMANORM Super Gradient for HPLC BDH BDH Methanol HiPerSolv CHROMANORM Ultra LC-MS BDH BDH Standard Containers are industry-standard, single-wall construction 304 stainless steel drums. Double-Wall Containers are stainless steel drums with double-wall construction offering secondary containment and dual relief valves. Specifications for Acetonitrile High-Purity Solvents available in the VWR Range of Returnable Containers Specification BDH83639 BDH83640 BDH83642 BDH85500 BDH85501 Description Acetonitrile HiPerSolv CHROMANORM Super Gradient for HPLC Acetonitrile HiPerSolv CHROMANORM LC-MS Acetonitrile HiPerSolv CHROMANORM Ultra LC-MS Acetonitrile HiPerSolv Ultra Low Water for Biopharma Acetonitrile for DNA Synthesis Assay Min 99.95% Min 99.90% Min 99.95% Min 99.97% Min 99.95% Identity IR Spectrum Conforms Conforms Residue on Evaporation Max 2 ppm Max 2 ppm Max 1 ppm Max 1 ppm Max 1 ppm Water Max 30 ppm <0.02% Max 10 ppm Max 5 ppm Max 10 ppm Coloration Max 10 APHA Max 10 APHA Max 5 APHA Max 10 APHA Max 10 APHA Density (d 20 C/4 C) Density (d 20 C/20 C) Refractive Index (in 20/D) Boiling Point Range C C C Acidity meq/g Max meq/g Max meq/g Max meq/g Max meq/g Alkalinity meq/g Max meq/g Max meq/g Max meq/g Max meq/g Spectral Characteristics Gradient at 210 nm Max 3 mau Max 3 mau Max 1 mau Gradient at 254 nm Max 1 mau Max 1 mau Max 1 mau Max 1 mau Fluorescence as Quinine at 254 nm Max 1 ppb Fluorescence as Quinine at 365 nm Max 0.5 ppb Fluorescence as Quinine at 254 nm Max 1 ppb Max 1 ppb Transmittance at 190 nm Min 10% Min 50% Min 10% Transmittance at 191 nm Min 30% Transmittance at 193 nm Min 60% Transmittance at 195 nm Min 80% Min 90% Transmittance at 200 nm Min 95% Min 80% Min 98% Transmittance at 210 nm Min 96% Min 95% Min 98% Transmittance at 215 nm Min 98% Min 99% Transmittance at 220 nm Min 97% Min 98% Min 99% Min 97% Transmittance at 230 nm Min 99% Min 99% Transmittance from 230 nm Min 98% Transmittance at 240 nm Min 99% Transmittance at 250 nm Min 99% Transmittance from 240 to 420 nm Min 99% Min 99% Absorbance at 190 nm Max 1 Max 1 4 VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL

5 Specifications for Acetonitrile High-Purity Solvents available in the VWR Range of Returnable Containers continued Specification BDH83639 BDH83640 BDH83642 BDH85500 BDH85501 Absorbance at 191 nm Max 0.5 Absorbance at 195 nm Max 0.1 Absorbance at 200 nm Max 0.02 Max 0.1 Absorbance at 210 nm Max 0.02 Max 0.02 Absorbance at 215 nm Max 0.01 Absorbance at 220 nm Max 0.01 Max 0.01 Max 0.01 Absorbance at 230 nm Max 0.01 Max 0.01 Absorbance from 230 nm Max Absorbance at 240 nm Max Absorbance at 250 nm Max Absorbance from 240 to 420 nm Max Max Max Conforms to ACS Yes Yes Conforms to ACS (HPLC/UV) Yes Yes Conforms to Reag. Ph Eur Yes Yes Yes Conforms to Reag. USP Yes Yes Al Max 50 ppb Max 20 ppb Max 0.1 ppm As Max 0.1 ppm Ba Max 20 ppb Max 0.1 ppm Ca Max 50 ppb Max 20 ppb Max 0.1 ppm Cd Max 20 ppb Max 0.1 ppm Co Max 20 ppb Max 0.1 ppm Cu Max 20 ppb Max 0.1 ppm Fe Max 50 ppb Max 20 ppb Max 0.1 ppm Hg Max 0.1 ppm K Max 50 ppb Max 20 ppb Max 0.1 ppm Ni Max 0.1 ppm Mg Max 10 ppb Max 20 ppb Max 0.1 ppm Mn Max 20 ppb Max 0.1 ppm Na Max 100 ppb Max 20 ppb Max 0.1 ppm Pb Max 20 ppb Max 0.1 ppm V Max 0.1 ppm Zn Max 20 ppb Max 0.1 ppm MS-ESI+ (as Reserpine) Max 2 ppb Max 2 ppb MS-APCI+ (as Reserpine) Max 2 ppb Max 2 ppb MS-ESI- (as 4- Nitrophenol) Max 20 ppb Max 20 ppb MS-APCI- (as 4- Nitrophenol) Max 20 ppb Max 20 ppb Acetamide Max 0.1 ppm Acetaldehyde Max 0.1 ppm Allyl Alcohol Max 5 ppm Propionitrile Max 250 ppm HCN Max 10 ppm Reporting Threshold (PhEur #2034) Conforms Identification Threshold (PhEur #2034) Quantification Threshold (PhEur #2034) Conforms Conforms Acrylonitrile Max 0.1 ppm Methacrylonitrile Max 0.1 ppm Crotononitrile Max 0.1 ppm Gradient Elution Test (a.u.) (as 210nm) Max 0.1 ppm FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM 5

6 SPECIFICATIONS FOR METHANOL FAMILY Specifications for Methanol High-Purity Solvents available in the VWR Range of Returnable Containers Specification BDH20864 BDH85681 BDH85800 Description Methanol HiPerSolv CHROMANORM Gradient for HPLC Methanol HiPerSolv CHROMANORM Super Gradient for HPLC Assay Min 99.8% Min 99.9% Min 99.9% Identity IR Spectrum Passes Test Residue on Evaporation Max 5 ppm Max 1 ppm Max 1 ppm Water <0.03% <0.02% <0.02% Coloration Max 10 APHA Max 10 APHA Density (d 20 C/4 C) Density (d 20 C/20 C) Refractive Index (in 20/D) Boiling Point Range C C C Methanol HiPerSolv CHROMANORM Ultra LC-MS Acidity Max meq/g Max meq/g Max meq/g Alkalinity Max meq/g Max meq/g Max meq/g Spectral Characteristics Gradient at 220 nm Max 3 Mau Gradient at 235 nm Max 2 Mau Max 2 Mau Gradient at 254 nm Max 1 Mau Max 1 Mau Fluorescence as Quinine at 254 nm Max 1 ppb Max 1 ppb Max 1 ppb Fluorescence as Quinine at 365 nm Max 0.5 ppb Max 0.5 ppb Transmittance at 210 nm Min 20% Min 45% Min 45% Transmittance at 220 nm Min 50% Min 65% Min 65% Transmittance at 225 nm Min 68% Min 70% Transmittance at 230 nm Min 74% Min 85% Min 85% Transmittance at 235 nm Min 80% Min 83% Min 90% Transmittance at 240 nm Min 90% Min 95% Transmittance at 250 nm Min 95% Min 95% Min 95% Transmittance at 260 nm Min 98% Min 98% Min 98% Transmittance from 280 to 400 nm Min 98% Min 98% Min 98% Absorbance at 210 nm Max 0.7 Max Max Absorbance at 220 nm Max 0.3 Max Max Absorbance at 225 nm Max Max Absorbance at 230 nm Max 0.15 Max Max Absorbance at 235 nm Max 0.1 Max VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL

7 Specifications for Methanol High-Purity Solvents available in the VWR Range of Returnable Containers continued Specification BDH20864 BDH85681 BDH85800 Absorbance at 240 nm Max Max Absorbance at 250 nm Max 0.02 Max Max Absorbance at 260 nm Max 0.01 Max Max Absorbance from 280 to 400 nm Max Max Conforms to ACS Passes Test Passes Test Passes Test Conforms to Reag. Ph Eur R Conforms to Reag. Ph Eur R Trace Metals Passes Test Passes Test Passes Test Passes Test Passes Test Passes Test Al Max 20 ppb Ag Max 100 ppb Ba Max 100 ppb Ca Max 200 ppb Cd Max 20 ppb Co Max 20 ppb Cu Max 10 ppb Fe Max 50 ppb K Max 50 ppb Mg Max 50 ppb Mn Max 100 ppb Na Max 200 ppb Ni Max 100 ppb Pb Max 20 ppb Zn Max 100 ppb MS-ESI+ (as Reserpine) Max 2 ppb MS-APCI+ (as Reserpine) Max 2 ppb MS-ESI- (as 4- Nitrophenol) Max 20 ppb MS-APCI- (as 4- Nitrophenol) Max 20 ppb Carbonyl Compounds Passes Test Solubility in Water Passes Test Substances Darkened by Sulphuric Acid Passes Test Substances Reducing Permanganate Passes Test FOR MORE INFO, VISIT VWR.COM/RECAP, OR CALL VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM 7

8 VWR RETURNABLE CONTAINER ADVANTAGE PROGRAM (ReCAP) HOW IT WORKS Contact your VWR Sales Representative for an assessment of your facility s solvent specifications and demands; your Rep will work with you to recommend the optimal solvent grade and create a personalized delivery schedule to ensure you always have the product you need. A fleet of VWR Returnable Containers will be dedicated to you. After your first shipment, let us know when you are running low and a full container will be on its way to you. If your needs ever change, we can easily adjust your delivery schedule and/or fleet size. Track all of your incoming and outgoing fleet containers to stay informed and on-schedule thanks to your containers unique serial number and VWR s tracking system. Work with us to create your dedicated VWR Returnable Container fleet Let us know when you re running low Receive a full container in exchange for the empty one 5909-KS-CM M Lit. No